Water Resources and Irrigation Local Bodies Closing in 0 days TDR #26509596

Jal Jeevan Mission- Kasaragod District -Madikkai Panchayath - Wss To Madikkai Phase Ii-Zone Ii-Reach Ii Jal Jeevan Mission- Kasaragod District -Madikkai Panchayath - Wss To Madikkai Phase Ii-Zone Ii-Reach Ii- ( Bangalam Area ) - Laying Distribution Sys

Issued by Local Bodies · MADIKKAI, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Jan 2021
0 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
8400
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
MADIKKAI → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Jal Jeevan Mission- Kasaragod District -Madikkai Panchayath - Wss To Madikkai Phase Ii-Zone Ii-Reach Ii Jal Jeevan Mission- Kasaragod District -Madikkai Panchayath - Wss To Madikkai Phase Ii-Zone Ii-Reach Ii- ( Bangalam Area ) - Laying Distribution System And Providing Fhtcs

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 18-Jan-2021 EXTENSION OF TENDER DATE Date 21-Jan-2021

BOQ

Work Name:Jal Jeevan Mission - Kasaragod District - Madikkai Panchayath - WSS to Madikkai Phase II- Zone II- Reach 2 (Bangalam area)-Laying distribution system and providing FHTCs
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11.01Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil (Ref. Item No. 2.10.1 of DSR)BI01010001010000000000000515BI01000011133408.15cum
21.02Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :\"Ordinary Rock. (Ref. Item No. 2.13.1 of DSR)BI01010001010000000000000515BI01000011146816.29cum
31.03\"Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :Medium Rock (blasting prohibited)New Data derived from DARBI01010001010000000000000515BI01000011153408.15cum
41.04Fencing one side of trenches, 1.50 m height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2 m intervals. (Data Prepared based on PWD SDB - Item No.1009)BI01010001010000000000000515BI01000011165800metre
51.05Fencing 1.50m high with two rows of casuarina poles (girth 15cm to 24cm) tied with coir yarn on vertical casuarina pole (girth 15cm to 24cm) fixed at 1.5m intervals.NEW DATA (Prepared based on PWD SDB - Item No.1009BI01010001010000000000000515BI01000011171700metre
61.06Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI0100001118197cum
71.07Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concreteBI01010001010000000000000515BI0100001119414sqm
81.08Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials) 50 mm nominal outer dia pipes.BI01010001010000000000000515BI01000011207500metre
91.09Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 90 mm nominal outer dia pipes.\"BI01010001010000000000000515BI010000112116110metre
101.1Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).110 mm nominal outer dia pipes.BI01010001010000000000000515BI0100001122350metre
111.11Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 140 mm nominal outer dia pipes.BI01010001010000000000000515BI0100001123305metre
121.12Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).160 mm nominal outer dia pipes.BI01010001010000000000000515BI01000011241565metre
131.13Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBRValue-25BI01010001010000000000000515BI010000112530cum
141.14Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials :200 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.17 in DARBI01010001010000000000000515BI0100001126490metre
151.15Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :BI01010001010000000000000515BI01000011275.55quintal
161.16Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :BI01010001010000000000000515BI01000011280.36quintal
171.17Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:200 mm dia pipesBI01010001010000000000000515BI0100001129100joint
181.18Labour for cutting DI pipe with steel saw.<br>200 mm diameter DI. pipeBI01010001010000000000000515BI010000113015Each Cut
191.19Testing 200mm DI/CI pipeline with potable water to the required test pressure 200 mm dia Observed Data derived from item no.1020 of PHED DATABI01010001010000000000000515BI0100001131490metre
201.2Supply ,stacking,spreading and consolidating of Quarry Muck in the trench of pipe line, including carriage, loading ,unloading & stacking up to any lead.BI01010001010000000000000515BI0100001132150cum
211.21Supply ,stacking,spreading and consolidating of Red earth in the trench of pipe line for cushion including carriage, loading ,unloading & stacking up to any lead.BI01010001010000000000000515BI0100001133225cum
221.22Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal boreBI01010001010000000000000515BI010000113412No
231.23Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal boreBI01010001010000000000000515BI01000011357No
241.24\"Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :80 mm diameter. Class I\"Observed Data derived from item no.18.31.of DARBI01010001010000000000000515BI01000011362Nos
251.25\"Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :100 mm diameter. Class I\"Data derived from item no.18.31.1.1of DARBI01010001010000000000000515BI01000011371Nos
261.26\"Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :125 mm diameter. Class I\"Data derived from item no.18.31.2.1 of DARBI01010001010000000000000515BI01000011381Nos
271.27Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :150 mm diameter. Class I\"Data derived from item no.18.31.3.1 of DARBI01010001010000000000000515BI01000011392Nos
281.28\"Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :200 mm diameter. Class I\"Data derived from item no.18.31.4.1 of DARBI01010001010000000000000515BI01000011401Nos
291.29Providing and fixing C.I double acting air valve of approved quality with bolts, nuts, rubber insertion etc. complete ( The tail pieces, tapers etc. if required will be paid separately):BI01010001010000000000000515BI01000011415Nos
301.3Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately): 25 mm Single acting Air Valve Observed Data derived from item no.18.59.of DARBI01010001010000000000000515BI010000114215Nos
311.31Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work40 mm dia nominal boreBI01010001010000000000000515BI0100001143150metre
321.32Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work80 mm dia nominal boreBI01010001010000000000000515BI0100001144210metre
331.33Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 100 mm dia nominal bore Observed Data derived from item no.18.12 of DARBI01010001010000000000000515BI010000114518metre
341.34\"Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 125 mm dia nominal bore Observed Data derived from item no.18.12 of DARBI01010001010000000000000515BI010000114612metre
351.35Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 150 mm dia nominal ore Observed Data derived from item no.18.12 of DARBI01010001010000000000000515BI010000114724metre
361.36Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soilBI01010001010000000000000515BI010000114912.096cum
371.37Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)BI01010001010000000000000515BI01000011501.008cum
381.38Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI01000011517.434cum
391.39Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columnsBI01010001010000000000000515BI010000115220.16sqm
401.4Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.BI01010001010000000000000515BI010000115329.401sqm
411.41Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or moreBI01010001010000000000000515BI0100001154587.2kilogram
421.42Supply of DI K9 Pipe Conforming to IS 8329/2000, 200mm Dia.BI01010001010000000000000515BI0100001156504.7metre
431.43Supply of PVC Pipe, 10 kg/cm2, 140mm Dia S/E including specialsBI01010001010000000000000515BI0100001157305metre
441.44Supply of PVC Pipe, 10kg/cm2, 50mm Dia S/E including specialsBI01010001010000000000000515BI01000011582000metre
451.45Supply of PVC Pipe, 8kg/cm2, 50mm Dia S/E including specialsBI01010001010000000000000515BI01000011593000metre
461.46Supply of PVC Pipe, 6kg/cm2, 90mm Dia S/E including specialsBI01010001010000000000000515BI01000011602905metre
471.47Supply of PVC Pipe, 6kg/cm2, 110mm Dia S/E including specialsBI01010001010000000000000515BI0100001161350metre
481.48Supply of PVC Pipe, 6kg/cm2, 160mm Dia S/E including specialsBI01010001010000000000000515BI01000011621565metre
491.49Supply of PVC Pipe, 8kg/cm2, 90mm Dia including specialsBI01010001010000000000000515BI01000011633685metre
501.5Supply of PVC Pipe, 10kg/cm2, 90mm Dia S/E including specialsBI01010001010000000000000515BI01000011649520metre
511.51Supply of 50mm Dia PVC 12.5 kg/cm2 Pipe S/E including specialsBI01010001010000000000000515BI01000011652500metre
521.52Supply of GI pipe 150 mm Medium including specialsBI01010001010000000000000515BI010000116625.201metre
531.53Supply of GI pipe 125 mm Medium including specialsBI01010001010000000000000515BI010000116712.601metre
541.54Supply of GI pipe 100 mm Medium including specialsBI01010001010000000000000515BI010000116818.9metre
551.55Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm.BI01010001010000000000000515BI01000011692No
561.56Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 100mm.BI01010001010000000000000515BI01000011701No
571.57Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 125mm.BI01010001010000000000000515BI01000011711No
581.58Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 150mm.BI01010001010000000000000515BI01000011722No
591.59Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 200mm.BI01010001010000000000000515BI01000011731No
601.6Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25mm.BI01010001010000000000000515BI010000117415No
611.61Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.BI01010001010000000000000515BI0100001176600Nos
621.62Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains from 140mm to 200mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.BI01010001010000000000000515BI0100001177280Nos
631.63Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing CI mains from 150mm to 200mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.BI01010001010000000000000515BI010000117898Nos
641.64Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers.BI01010001010000000000000515BI010000117939120metre
651.65Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers.BI01010001010000000000000515BI0100001180978Nos
661.66Geo tagging of water supply connections as per the direction of Engineer in chargesBI01010001010000000000000515BI0100001181978No
671.67Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffice diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.BI01010001010000000000000515BI010000118220400metre
681.68Dismantling bituminous road by manually or mechanical means and disposal of materials with 50m lead as per the direction of Engineer in chargesBI01010001010000000000000515BI01000011833660sqm
691.69Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI0100001184549cum
701.7KWA Water connection Charges upto 30 m length of service main.BI01010001010000000000000515BI0100001185978No
711.71KWA additional connection fee for Service line greater than 30m.BI01010001010000000000000515BI0100001186300No

AI Tender Summary

OUR REF NO 26509596
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 21-01-2021
Authority
Authority Name Kerala Water Authority
Work Description Jal Jeevan Mission- Kasaragod District -Madikkai Panchayath - Wss To Madikkai Phase Ii-Zone Ii-Reach Ii Jal Jeevan Mission- Kasaragod District -Madikkai Panchayath - Wss To Madikkai Phase Ii-Zone Ii-Reach Ii- ( Bangalam Area ) - Laying Distribution System And Providing Fhtcs
Basic Detail
Tender No 135/2020-21/PHC/KNR
Bidding Type Tender
Location
City MADIKKAI
State Kerala
Key Dates
Publish Date 18 Jan 2021
Submission Date 21 Jan 2021
Open Date 23 Jan 2021
Finance
Tender Value Ref. Documents
Tender Fee 8400
EMD 1 Lakhs
Exemption Not Available
Document List
D16EC696-F751-451E-A41E-06D6075C3911.html
Form84.pdf
preliminary.pdf
Form83.pdf
KWAGeneralConditionsforeTenderingV5.pdf
BOQ_575077.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 18, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 21, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 21, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 23, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

D16EC696-F751-451E-A41E-06D6075C3911.html

pdf

Form84.pdf

pdf

preliminary.pdf

pdf

Form83.pdf

pdf

KWAGeneralConditionsforeTenderingV5.pdf

xls

BOQ_575077.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender