Water Resources and Irrigation Government Departments Closing in 0 days TDR #26500445

Execution , Testing And Commissioning Of Balance Work For Lakhipur ( Goalpara ) Town Water Supply Scheme Execution , Testing And Commissioning Of Balance Work For Lakhipur ( Goalpara ) Town Water Supply Scheme Under Dhubri Division Of Assam Urban W

Issued by Government Departments · Lakhipur, Goalpara District, Assam, Assam
Tender Value
1.88 Crore
Estimated cost
Bid Submission
20 Jan 2021
0 days left
EMD
3.77 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lakhipur, Goalpara District, Assam → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Execution , Testing And Commissioning Of Balance Work For Lakhipur ( Goalpara ) Town Water Supply Scheme Execution , Testing And Commissioning Of Balance Work For Lakhipur ( Goalpara ) Town Water Supply Scheme Under Dhubri Division Of Assam Urban Water Supply Sewerage Board

BOQ

Name of Work : Execution , Testing and Commissioning of balance work for Lakhipur (Goalpara) Town Water Supply Scheme.
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11A. Supplying and laying of distribution pipe network
22Supply & delivery of Ductile Iron Pipes for water conforming to IS: 8329 - 2000 (with latest amendment, current at the time of delivery) at site of the contractor store location . The pipes shall be suitable for Push- on Joint (Rubber Gasket Jointing) with Socket and Spigot ends in standard working lengths of 5.5 m. / 6.0 m. of requisite pressure class, with cement mortar lining inside the pipes (with Portland cement conforming to IS: 8112) and Zinc coating with a finishing layer of Epoxy Resin (Blue Epoxy) on external surfaces, manufactured by manufacturer having the eligibility criteria and as per other terms & conditions as prescribed in the Bid Document.
33100 mm dia3500RM
44150 mm dia800RM
55200 mm dia270RM
66Supplying, fitting, fixing ,commissioning of ISI marked DI double socketed fittings class k-12 conforming to IS 9523-2000 of PN 1.6 with up to date amendment of required diameter suitable for used with DI spun pipe conforming to IS 8329-2000 of class k-7 DI pipe along with necessary rubber ring of EPDM quality conforming to IS : 5382-1985 such as (i)90 degree, 45 degree, 22.5 degree, 11.25 degree bend (ii) Equal Tree, reducing Tree (iii) DI socketed reducer/ Taper (iv) DI Collar(v) DI Flanged and socketed tail piece/spigot (vi) Double socketed Flanged Tee for Air Valve6670Kg
77Supplying and delivery of Cast of resilient seated Cast Iron Air Relief Valves conforming to IS:14845-2000 to DI water distribution pipe line including supply, fitting fixing of insertion sheets (gaskets), nuts and bolts with washers, etc. all complete as directed and specified of 76.30 diameter.4Each
88Supplying and delivery of Cast Iron Double Flanged (CIDF) sluice valve with hand wheel (Class PN-1.6) conforming to Conforming to IS:14846/2000 with up to date amendments of any reputed make to the distribution pipe lines including supply, fitting, fixing of insertion sheets (gaskets), nuts and bolts with washers, etc. and including all taxes and duties, all complete as directed and specified of following diameter.
99100 mm6Each
1010150 mm2Each
1111200 mm2Each
1212Providing rubber gasket joints to DI, S&S pipes including carriage of the materials but excluding the cost of rubber gasket all complete as directed.
1313100 mm dia600Each
1414150 mm dia160Each
1515200 mm dia54Each
1616Earth work in excavation in foundation trenches including refilling the quantity as necessary after completion of works of pipe line dressing, rammimg, watering etc and removal of surplus earth with 50m lead and lift upto 1.5m all complete including dewatering as directed including bailing out water where necessary. Hard Soil5546.37Cum
1717Earth work in excavation for metallic road surface (average thickness of 40 cm) including the removal of road metal, boulders, and refilling the same properly and including restoration of road surface to its original condition, all complete as directed.2755.25Sqm
1818Earth work in excavation in black topping road surfaced (average thickness of black topping 35 mm) including the removal of road, metal, boulders, and refilling the same properly and including restoration of road surface to its original condition (except black topping as the black topping to be done by the PWD on necessary payment) all complete as directed.2009.98Sqm
1919Labour charge for carrying and laying in position Ductile Iron(DI) pipes in line level all complete as directed for the following diameter of pipe.
2020100 mm3000RM
2121150 mm800RM
2222200 mm270RM
2323Labour charge for carrying and laying in position Ductile Iron(DI) sluice valve (with wheel and cap) C.I. reflex valve complete with supplying bolts and nuts, 3mm thick rubber insertion sheet etc (the tail piece if required will be paid separately), all complete as directed (one valve and two flanged joints)
2424100 mm6Each
2525150 mm2Each
2626200 mm2Each
2727Labour charge for carrying, placing in position, fitting and fixing C.I. double air valve complete with supplying bolts and nuts, 3 mm thick rubber insertion sheet etc all complete as directed for 76.2mm dia6Each
2828Construction of Valve Chamber of inside measurement 1000mm x 1000mmx 1600mmhigh(1500mm below 300mm above GL) with 100mm thick cement concrete base of prop. 1:3:6 (1 cement : 3 coarse sand: 6 aggregates) over flat brick soling, 345mm thick brick wall in cement mortar in prop. 1:4 (1 cement: 4 fine sand) finished with 15mm thick cement plastering on complete inside walls and floor & upto 0.5m from top on outside walls in prop. 1:4 (1 cement: 4 fine sand); 150mm thick RCC Pit cover in prop. 1:1.5:3 ( 1 cement: 1.5 coarse sand: 3 aggregate) with double layer reinforcing mesh of 16mm dia TMT bars @125 c/c both ways, including supply of all labour and materials, all complete as directed and specified.12Each
2929Labour charge for cutting DI pipe of different dia for required length as directed.150Each
3030Supplying & providing of PCC thrust block as per standard design & drawing having concrete mix 1:3:6 ( 1 Cement : 3 Coarse sand :6 Stone Aggregate 40 mm nominal size) having average size 600x600x600 mm10Each
3131Labour charge for carrying, placing in position S & S flanged, plain ended C.I Specials such as tees, bends, collars, tappers and caps etc all complete as directed.66.7Qntl
3232B. Road and Culvert Crossing of distribution pipe network
3333Supply of electrically welded steel pipe for water and sewerage as per IS 3539:1931 and steel grade shall having the fe410 chemical requirement specification as per IS 3589 of thickness 7.9 mm for 100 mm dia. 245.00 RM and 150 mm dia. 177.90 RM.9124.91Kg
3434Supply of cast Iron Detachable (CID) Joints (Class-15) conforming IS 8794-1988
3535100 mm dia.54Each
3636150 mm dia.36Each
3737Supply of Rubber Ring of EPDM quality (Tyton Joint) as per IS 5382:1985
3838100 mm dia.31Each
3939150 mm dia.12Each
4040Labour charge for carrying and fixing MS pipes complete with MS Fitting specials with jointing materials and supplying the jointing all complete as directed , excluding trenching and refilling of earth ( external work).
4141100 mm245RM
4242150 mm177.9RM
4343Jointing MS pipe in line level and level by electric arc welding (butt) in three run making grooves of V shape by electric grinder and welding with Vordin 3.15/ 4.00 mm welding arc welding rod including supply of welding road providing power etc all complete as directed by the Executive Engineer In charge.7324.05CM
4444Outside coating of pipe line by approx paint in two coats over a coat painting of Johnson & Nicholson as directed163.71Sqm
4545C. Leakage Repairing of existing distribution pipe network.
4646Leakage repairing of pipeline laid along the concrete bituminous roads/ lane, dismantling CC layer and excavation of base/sub grade/earthwork and refilling with proper compaction of excavated earth/ base/sub grade and finally providing , laying and placing CC in M15 grade of minimum 150 mm thick with proper curing including proper precaution / protection measure of excavated area till final completion of work to the satisfaction of the Board all complete as directed.10Job
4747Leakage repairing of pipeline laid along the paver block topping roads/ lane, dismantling paver block and staking properly and securely for ensuring reuse of the same ( minimum savage value of 90%). excavation of sand base /sub grade/ if any for purpose of leak repairing /restoration of pipe line including refilling of excavated materials with proper completion of earth sand base and sub base properly and finally laying placing inter locking the savaged paver blocks including supplying, laying and placing additional ( Maximum 10%) paver block to renew the road surface and the necessary precautionary / protection measures for all the excavated area till final completion of works to the satisfaction of the Board all complete as directed.12Job
4848Leakage repairing of pipeline laid along the earthen roads/ earthen side berms/ gravel and refilling excavated materials with appropriate completion including precautionary / protection measures for all the excavated area till final completion of works to the satisfaction of the Board all complete as directed.18Job
4949Supply of cast Iron Detachable (CID) Joints (Class-15) conforming IS 8794-1988
5050100 mm dia.54Each
5151150 mm dia.30Each
5252200 mm dia.20Each
5353Labour charge for replacement and laying new AC Pipes where necessary at already existing laid distribution pipe network. (Pipe supplied by the Board)
5454100 mm dia.50Each
5555150 mm dia.35Each
5656200 mm dia.12Each
5757D. Road Restoration for laying distribution pipe network
5858Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal up to a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.\nFilling in foundation trenches as per drawing and technical specification Clause 305.3.9.600Cum
5959Construction of gravel/soil-aggregate base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with three wheel 80-100 kN static roller to achieve the desired density, complete as per Technical Specifications Clause 402255.332Cum
6060Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 1 as per Technical Specification Clause 405.112.5Cum
6161Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/Sqm using mechanical means as per Technical Specification Clause 502412.587Sqm
6262Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification clause 1504 complete including carriage.420Sqm
6363E. SANITARY AND WATER SUPPLY WORK
6464Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil26.22cum
6565Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (b) With hill sand obtained by truck carriage loading and unloading, and carriage to the site of work.1.44Cum
6666Pre construction anti - termite treatment by applying in the entire leveled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) liters per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (trice or equivalent) and water, i.e. 1% solution.16.86Sqm
6767Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.22.09Sqm
6868Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.7.2Sqm
6969Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).(a) In prop 1cement: 3 sand :6 coarse aggregate by volume2.34Cum
7070Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level)6.84Qntl.
7171Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:\nFoundation, footings, bases of columns, pile cap, raft and mass concrete works etc.\n(a) Using 38mm thick plank52.34Sqm
7272Brick work in cement mortar with 1st class brick including racking out joints and curing complete as directed.\n(I) In Sub-structure upto plinth level including dewatering if necessary\n(b) In proportion 1:4.3.82Sqm
7373Providing pre cast RCC slab over drain septic tank etc. in prop. 1:2:4 reinforcement with 10 mm M.S bar @ 150 mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering curing etc.7.41Sqm
74741st class brick nagged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embedded in cement mortar and will be measured and paid separately)\n(A) 112mm thick brick wall\n(a) In cement mortar in proportion 1:4.(1 cement:4 sand)17.15Sqm
7575Providing, fitting and fixing PVC door frame of Duroplast make DPF-5060 make suitable for DPS-3720 made from extruded PVC multi chamber hollow section having dimensions of 50mmx60mm (Tolerance + 1mm). Horizontal and vertical sections shall be joined by steel screws after inserting M.S. tubular rectangular galvanized L-shaped brackets of size 100mmx100mm or plastic brackets of size 75mmx75mm with metered cut at the corners. Hinge side of the frame shall be reinforced with M.S.Tubular section of size 40mmx20mm. The frame will be fixed to the column/ stiffener/ wall with the help of 3 nose 75mm long and 4mm dia steel screws and expandable fasteners on each side of the door frame complete in all respects as specified and directed at all levels.10.06RM
7676Providing, fitting and fixing PVC Door shutters of Duroplast DPS 3720 make made from extruded PVC stiles and rails made from rigid PVC multi cavity hollow chamber section of size 90mmx37mm (Tolerance+ 1mm). The corners of the stiles and rails shall be metered out and fixed to each other with the help of solid plastic L-shaped brackets or M.S. rectangular tubular galvanized two nos of size 200mmx100mm and 100mmx100mm at each corner by self tapping steel screws. PVC multi cavity hollow section of size 105mmx37mm shall be fixed in the middle by aluminum cleat and steel screws as lock rail. The section frame shall then be filled with PVC panels of approved colour of size 100mmx20mm. Then two numbers of bright steel rods of 6mm diameter shall be inserted horizontally through stiles and panels with two numbers of check nuts and washers all complete as specified and directed at all levels. (Door fixtures and fittings to be measured and paid separately).2.8Sqm
7777Supplying, fitting, fixing anodised aluminum fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminum screws etc. complete.( anodised to bright natural matt & satin finished )
7878a) Sliding door bolts ii) 250mm x 16mm4Each
7979b) Tower bolts ii) 250mm x 12mm4Each
8080c) Door handles iii) 150mm4Each
818125 mm thick cement concrete topping 1:2:4 (1cement : 2 coarse sand : 4 coarse aggregate of 12 mm nominal size) finished with a floating coat of neat cement finish to be laid in panels including curing complete as directed.2.6Sqm
8282Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor.\n(a) 15 mm thick.1.86Sqm
838315 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side
8484a) In cement mortar 1:32.92Sqm
8585b) In cement mortar 1:442.06Sqm
8686Applying one coat cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.25.92Sqm
8787Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after thoroughly brooming the surfaces to remove all dirt and remains of loose powdered materials.25.92Sqm
8888Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately)\n(i) Universal Closet S Trap (Cat No.C0271) (Anglo Indian) (inclusive of seat cover).1each
8989Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug, PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately)\n(a) White\n(i) Duke 660 x 495 (Cat. No.C8416/27) (white/ coloured).1each
9090Supplying, fitting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)\na) White\n(i)Economy Single Flush (Cat No.C8090/C8055).1Each
9191Supplying fitting and fixing Telephonic Chrome Plated (C.P.) shower of approved brand as directed and specified. (Pipes will be measured and paid separately)\n(b) Telephone shower deluxe with 1.5m PVC tube and swinging hook.\n1Each
9292Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) \n(i) Bib Cock ( Code.No.RG-5015).3Each
9393Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified.1Each
9494Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug, PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately)\nPEDESTAL BASIN (with pedestal)\n(a) White\n(i) CEDER 570 x 440 (Cat. No.91049/91115).1Each
9595Supplying, fitting and fixing of PVC pipe of 6kg/sqrm (supreme/prince) or other ISI approved ….. Including required bend, tee, socket, cowel, floor trap etc. as necessary complete at all levels including below GL as directed and specified.20RM
9696Supplying and placing plastic cylindrical vertical clause top (PCVC) tank of Sintex / Polycon / Patton make over the staging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes. (b) Polycon make1Each
9797Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed \nB) UPVC pipe with UPVC fittings ( Using UPVC high pressure pipe) (Using SUPREME/ PRINCE/ SFMC/ FUSION brand pipe)\niii) 25mm diameter.55.5RM
9898Providing ceramic Tiles of approved quality, size, shape and thickness not less than 8 mm on floors, skirting’s, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement: 3 coarse sand ) including cutting where necessary finished with flush pointing with fix-A Tile Choksey/ Sika/ Pedelite/ Roof/ White cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed ( colored pigment should be in conformity with colour of slab and as approved and directed by the Department).\nDeluxe range (So many/ Orient/Nitco/Qutone Make)\nOf size 600mmx600mm and above.18.41Sqm
9999F. Grunting and Floor repairing of Underground Sump
100100Providing Grouting by drilling holes @ 1M c/c upto half of the slab/ wall depth in zigzag manner or as per drawings using a drill machine and fixing a nozzle of 18 to 20mm dia. for injecting a grout slurry of cement admixed with expanding grout admixture Intraplast EP of Sika India Ltd./Dr. Sealkit NSPG (Asian Chemicals) / FLOWCABLE 50 OF BASF@ 1.0% by weight of cement and water resistant bonding agent Sika Latex, till the refusal of injected grout material from adjacent nozzle (grouting operation pressure shall be in between 3 to 4kg per sq.cm.). Followed by cutting the exposed nozzle so as to make the wall free from the grouting pipes and to seal the gap with polymer modified mortar as specified and directed by the Department complete at all levels.316.41Sqm
10110115 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. \nA) On rough side\nb) In cement mortar 1:4202.95Sqm
10210265 mm thick cement concrete floor consisting of 53 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 12 mm thick wearing coarse of cement sand plastering in prop. 1:2 laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square meter of floor area) including curing etc. complete as directed.50.46Sqm
103103Doing patch work in roof slab/ Raft slab wherever necessary by laying small portions of Polymer modified mortar - Cement sand mortar (in prop 1:4) mixed with 100% acrylic Polymer Master Crete M-81 of Choksey Chemicals/Dr. Seal kit Sealcrete (Asian Chemicals) / Rheomix 115 of BASF@ 4% by weight of cement as specified & directed by the Department complete after proper surface preparation (surface preparation including thorough cleaning of surface to be measured and paid separately).50.46Sqm
104104Supply, Fitting, Fixing of Bamboo scaffolding for construction works1Job
105105G. Electrical installation of Clear Water and Raw Water pumping set and Other electrical works
106106Supplying, Fabrication, Erection, Testing commissioning of vermin and dust proof (IP-43 protection) totally enclosed cubical type compartmental floor mounting panel board of size 1450mm x 1000mm x 500mm made of 16 SWG (1.66mthick C.R. sheet and 300mm x 30mmx5mm MS Angle having 4 no legs at the bottom and C.R. sheet roofing on the top complete painting with 2 coats of Red Oxide metal primer and 2 coats of Enamel paint. The panel board is to be erected in 1:3:6 PCC foundations including excavation Complete neatly Wiring done, with the provision for the following Electrical Accessories.\nIncomer 125A ,4Pole 25KA AC 415V MCCB with D.P. Handle OUTGOING TPN MCB : 5nos\n0-125 A digital Ammeter : 1 no.\n0-500 V digital Ammeter : 1 no.\nAmmeter selector switch : 1 no.\nVoltmeter selector switch : 1 no.\nIndicator lamp (R,Y & B) : 3 nos.\n2 Amp Slide lock fuse : 3 nos.\n400 CT Coil : 3 nos.\nControl wiring along with Busbar.1each
107107Supplying with fitting and fixing panel mounting open execution 415V 50Hz 4P MCCB with Microprocessor Release (Ics=Icu, adjustable Over Load and Short Circuit setting, neutral adjustable with earth fault protection Without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
108108i) MCCB 40A for Clear Water Pump & motor2each
109109ii) MCCB 100A for Raw Water Pump & Motor1each
110110iii) MCCB 63A for Air Blower2each
111111Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
112112i) MCCB 16A for Vacuum Pump1each
113113ii) Starter for Vacuum Pump1each
114114Supplying with fitting and fixing panel mounting open execution 415V 50Hz 4P MCCB with Microprocessor Release (Ics=Icu, adjustable Over Load and Short Circuit setting, neutral adjustable with earth fault protection Without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\ni) 400A for main transformer.1each
115115Supplying with fitting and fixing TPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\ni) 6A to 32A for lighting work.6each
116116Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminum conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminum strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armored U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Hovels/ RPG/CCI/Polycab/Glister/ Finolex make) .
117117i) 10 Sqm 3 core armored UG cable for transformer to main panel board.50RM
118118ii) 150 Sqm 3.5 core armored UG cable for transformer to main panel board50RM
119119iii) 50 Sqm 3.5 core armored UG cable for PH to Filter House20RM
120120iv) 25 Sqm 3.5 core armored UG cable for main panel to CW Motor Starter24RM
121121v) 25 Sqm 3 core armored UG cable for CW Motor to Starter20RM
122122Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminum conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminum for single core up to 70 sq mm balance Aluminum strip, Galvanized for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanized steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armored U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make). \n10.00 Sq.mm 3 Core armoured U.G. cable \n1710RM
123123Supplying Fitting and Fixing of (DOWELLS/ COMET make) copper tube terminal heavy duty BIS 4579.
124124(i) Copper tube terminal heavy duty BIS 4596 Size: 3008each
125125(ii)Copper tube terminal heavy duty BIS 4595 Size: 24016each
126126(iii) Copper tube terminal heavy duty BIS 4593 Size: 15024each
127127(iv) Copper tube terminal heavy duty BIS 4590 Size: 7013each
128128Supply with installation & commissioning of readymade maintenance free CPRI approved technology G.I. CHEMRODE ELECTRODE complete with RESLOW Grounding Minerals (25 K and Advance Earth Pit cover (PV including excavation of earth pit and construction brick earth chamber including plastering both inner & outer surface of brick wall as specified and directed by the deptt.1each
129129Supply of Extra for using salt (5 K and Charcoal (96 K in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .1each
130130Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.125RM
131131Wiring for light/ fan/ call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistoried) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/ Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, ceiling rose etc. complete as directed and specified by the Deptt.
132132(i) Medium point up to 6.00 meter. Length.4each
133133(ii) Long point up to 10.00 meter. Length.5each
134134Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multi strand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/ Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including providing and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Color kany.Kom / Hovels or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete. \n Extra Long point up to 20.00 meter. Length.\n2each
135135Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistoried) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabul /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity.\nWith 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in flat 25mm ISI marked casing 'n' capping system.\n50RM
136136Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator].\nPremium model 1200 mm Sweep (ORIENT PSPO make) / Premium model 1050 / 1200 mm Sweep SS-390 Deco Havells make)\n2each
137137Supplying and fitting of 18/20 Watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/ pendent holder etc. as specified and directed by the deptt.9each
138138H. Consruction of Power Sub-station
139139Supplying and erection of PSC pole 9.50 m long the pole, the pole is to be erected in 1:2:4 plain cement concrete foundation of size 1.50m X 0.45m x 0.45m having PCC base foundation 15cmx 60cmx 60cm including edge brick soling and plastering above GL portion(0.30m) complete with excavation of earth, handling of surplus soil, debris etc. to the proper place and refilling etc. as specified and as directed by the department. PSC pole 7.50 m long2Each
140140Supplying and fitting, fixing of galvanized L.T-T cross Arm with clamps, bolts, nuts etc. as required and directed by the Department. galvanized L.T-T cross Arm2Each
141141'Supply fitting and fixing of GI Ch Cross arm ( 75x40x6x2200mm)6Each
142142Supplying and fixing Pole Clamp of GI flat 50x6 mm complete as required and directed by the Department. POLE CLAMP10Each
143143Supplying and fixing of ACSR \" Raccon' conductor0.165KM
144144Supplying and fixing of 11 Kv Polimeric pin insulator3Each
145145Supplying including fitting and fixing 11 KV Disc Insulator, 70 KN in the existing MS Channel as required and directed by the Department. 11 KV Disc Insulator, 70 KN6Each
146146Supply fitting and fixing of 11 KV GOAB switch set- 150 Amps1Set
147147Supply fitting and fixing of11 Kv DO Fuse set- 150 Amps1Set
148148Supply fitting and fixing of 11/04 Kv 63 KVA DTR ( 4 Star ) BIS level-21Each
149149Supply fitting and fixing of DTR fencing as per REC standard specification complete with materials and labour1Job
150150Supplying including installation of 100 mm dia C.I. Earth Pipe as required and directed by the Department.100 mm dia C.I. Earth Pipe8Each
151151Supply and fitting and fixing of Copper wire 6 SWG10Kg
152152Supplying and fixing of 11 KV, 5KA lighting arrestor(Poly) set complete as required and directed by the Department. 11 KV, 9 KA lighting arrestor1Set
153153Supplying and erection of H.T. stay set complete (Galvanized) with 19mm dia x 1.8m long stay rod, anchor plate of size 30cm x 30cm x 6.4mm, thimble stay clamps, turn buckle (19mm x 60cm) 7/3.15 mm dia G.I. stay wire and strain insulator etc. in cement concrete 1:3 :6 mix foundation including excavation and refilling etc. as required by the department H.T. stay set complete2Set
154154Supply , fitting and fixing of Stay wire 7/10 SWG.20Kg
155155Supply , fitting and fixing of 11 Kv Guy Insulator2Each
156156Supplying , fitting & fixing of bio-metallic aluminum lugs 50 mm (Assorted) as required and directed by the Department. bio-metalic aluminum lugs-Assorted7Each
157157Supply and fitting of GI nuts and bolts with GI washer (assorted)25kg
158158Supply and fitting of LT I core XLPE Cable -50 Sqm.80Meter
159159Supply and fitting of GI wire 8 SWG (Guarding)20kg
160160Supplying and fitting, fixing of H.T. Danger Plate as required and directed by the Department.100 mm dia C.I. Earth Pipe2Each
161161Supplying with fitting and fixing of LT CT 75/5A 0.5 class.4Each
162162Supplying , fitting & fixing of three phase LT/CT Trivector energy meter as required and directed by the Department.LT/CT Trivector energy meter1Each
163163Supplying , fitting & fixing of metering cabinet as required and directed by the Department. metering cabinet1Each
164164Supply , fitting and fixing of MCCB-200 A lcs -100 % ICU1Each
165165I. Extrnal Electrification
166166Supply, fitting & fixing of Pole with the following specification as per IS 2713 :410SP43\nLength of pole = 10.00 meter.\nLength of sections, Bottom= 5.20 M, Middle = 2.40 M,Top =2.40 M, \nOutside dia. & Thickness Bottom = 165.10 x 4.50 mm, Middle.5each
167167Supplying with fitting & fixing of the following integral type street light luminaries complete and consisting of single piece integral epoxy gray powder coated dia cast aluminum housing gasket, pot optic reflector, cast aluminum frame from heat resistance toughened clear glass cover and accessories such as Condenser, lamp Holder, Ballast, lamp etc. in the existing pole including making necessary connection as approved by the Deptt.)with 2× 2.50 sq.mm F.R. multistoried and P.V.C. insulated single core copper cable as specified and directed by the department.
168168Philips make) Cat No.SRX051 1xSON250W For Lamp 1xSON/SONT250W/ Wipro make) Cat ref: WST 50250, For Lamp 1x250W HPSV (/ Crompton Greaves make) SSSGUN15H/GF or lamp 1x250W HPSV (T) .5each
169169Supply and laying of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmored /Armour (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988, U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make). \n 6.00 Sq.mm 3 Core armoured U.G. cable.323RM
170170Supplying fitting and fixing including necessary connection as approved by the Deptt.)of Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) of following type and capacity as specified and directed by the Department. ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) \nFully Automatic citation Star delta Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) for 22 - 30 A 30 HP motor.1each
171171Supply and laying of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured/Armour (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988, U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . \n16.00 Sq.mm 3 Core armoured U.G. cable.\n323RM
172172J. Submersible Raw water pumping set
173173Supply, installation, testing and commissioning of electrical driven Submersible Raw water pumping set (couple type) suitable for operation with 415 (+10 %) V, 3-phase, 50 Hz + 3% power supply with panel board including Star Delta starter (AC incorporating incomer MCCB, three air break contactors for main/delta/star as required) etc. with suitable size/capacity & following specification of pump/ motor along with all accessories such as bends, non return valves, sluice valve, clamps with nuts & bolts, clips etc. in all respect (excluding rising delivery pipes and specials fitting, fixing & testing etc.).Discharge 18.23 LPS, Head 45 M and 17.50 HP1Job
174174Supplying and fixing required size of copper cable ( branded ) for power line from pane board to starter and starter to motors as per specifications of the above mentioned pumping sets.
17517510 sqmm Urmoured cable for Motor and Starter120Rm
17617616 mm Sqm 3 core rumored Cable10Rm
177177Supplying, placing, laying, fitting and fixing of suction / delivery of 125 mm dia G.I pipes (TATA, Medium) along with its accessories/specials etc. as per requirement in the field for the above mentioned pumping set as per specifications.36Rm
178178K. Electrical driven Clear Water Centrifugal Pumping Sets
179179Supplying, installation, testing and commissioning of 1(one) number of 20 HP electrical driven centrifugal clear water pumping sets along with induction type motor suitable for operation with 415v + 10% 3 – phase, 50 Hz + 3% power supply with necessary fitting materials like rubber gasket 4.00 mm thick in quality and in conform to IS: 5382/1985. full thread Nut& Bolts, MS Flange, MS Reducer as per required size.1Job
180180Supply, installation, testing and commissioning of 100 mm dia of electrically welded steel pipe for water and sewerage as per IS 3539:1931 and steel grade shall having the fe410 chemical requirement specification as per IS 3589 of thickness 7.9 mm Manifold type common header , connecting with delivery of Clear water pumps and clear water pumping mains with outside coating of pipe line by approx paint in two coats over a coat painting of Johnson & Nicholchon with all complete as directed and specified.20Rm
181181Supplying and delivery of 100 mm dia. cast iron double flanged (CI/DF) sluice valve with hand wheel (Class PN-1.6) conforming to relevant BIS Specifications (with latest amendment, current at the time of execution), of any reputed make to the distribution pipe lines including supply, fitting, fixing of insertion sheets (gaskets), nuts and bolts with washers, etc. and including all taxes and duties, all complete as directed and specified.1No
182182Supplying and delivery of 100 mm dia resilient seated cast iron double flanged Horizontal Non -Return Valves conforming to IS:5312/2004 and PN 1.6 with up to date amendments to water distribution pipe line including supply, fitting fixing of insertion sheets (gaskets), nuts and bolts with washers, etc. all complete as directed and specified.1No
183183Supplying ,delivery , fitting and fixing of 98.5 mm dia resilient seated Cast Iron Air Relief Valves conforming to IS:14845-2000 to water distribution pipe line including supply, fitting fixing of insertion sheets (gaskets), nuts and bolts with washers, etc. all complete as directed and specified.1No
184184L Mechanical works at Treatment Plant.
185185Supply of electrically welded steel pipe for water and sewerage as per IS 3539:1931 and steel grade shall having the fe410 chemical requirement specification as per IS 3589 of thickness 7.9 mm for following dia\n 100 mm dia for pump house to back wash Tank=25.00rm\n100 mm dia for water tank to filter house back line=15.54 Rm\n200 mm dia for delivery of back wash water =22.00\n150mm dia UGR to pump house connecting=9.50 Rm\n150 mm dia pump house to CWPM =15.50\n200 mm dia filter house to UGR=38.513729.76kg
186186Supplying and delivery of cast iron double flanged (CI/DF) sluice valve with hand wheel (Class PN-1.6) conforming to relevant BIS Specifications (with latest amendment, current at the time of execution), of any reputed make to the distribution pipe lines including supply, fitting, fixing of insertion sheets (gaskets), nuts and bolts with washers, etc. and including all taxes and duties, all complete as directed and specified for following dia.
187187100 mm dia.4Each
188188150 mm dia.4Each
189189200 mm dia.4Each
190190Supply of Mild Steel Flange 16 mm thick for the following dia
191191100 mm dia.8Each
192192150 mm dia.8Each
193193200 mm dia.8Each
194194Supply, Fitting ,Fixing & Testing of Rotary Air Blower of reputed make along with electrical drive motor matching with filter unit having 2 (two) bed of size 5690 mm × 5385 mm each, and capable of delivering Air at the rate of 0.35 Kq/cm2 pressure at the under drainage system including pressure gauge, base frame for the air compressor & electric drive motor, coupling of the compressor with drive motor, rubber mountings, all complete\n Specification\n1. Air Blower Compressor\nMake: KAY International\nModel: 610 AC\nPressure: 0.35 kg/sqrm\nSuction Capacity: 740 cum/Hr.\nRPM: 1440\nMotor Make: 20.0 HP (Crompton/ Marathon/Kirloskar)\nPanel Board with starter & other controls1Job
195195Supply, fitting and Fixing of Galvanized Iron(GI) Pipe as per the IS specification conforming to IS-1239(pt-I), 1990 with special with jointing & supplying the material all complete as directed for 100 mm dia TATA(Medium) pipe for Air Blower.35RM
196196Providing , fitting and fixing of UPVC. Pipes of class IV( 10 kg/cm2 threaded plumbing & casing PVC pipes (Blue/Off White colures) with fitting material as required for laterals of filter for 110 mm dia Pipe96RM
197197Providing 12mm dia. hole for lateral @ 215mm center to center and fitting fixing over filter bed as directed.35No
198198Providing PVC End Cap for laterals.(Fenolex brand) of 110 mm dia70No
199199Supply of rubber gasket 4.00 mm thick in quality and in conform to IS: 5382/1985. The PCD and flange hole dimension should conform to IS 1538/1993 and gasket should be suitable for making flanged joint.30kg
200200Supply fitting and fixing of Bleecing Dozer including all Accessories as per direction of Engineer in-charge .1Job
201201Supplying and delivery of ISI Marked CI Jeffy Joints Collar (Flanged Adopter) with full threaded Nuts & Bolts for use with DI pipes Conforming to IS:14846/2000 with up to date amendments of 150 mm dia sizes. (PN-1.6)1Each
202202Labour charge for carrying and fixing MS pipes complete with MS Fitting specials with jointing materials and supplying the jointing all complete as directed , excluding trenching and refilling of earth ( external work)
203203100 mm dia.40.45RM
204204150 mm dia.25RM
205205200 mm dia.55.75RM
206206Providing Flange joints to Double Flange C.I. pipes and specials with testing of joints including carriage of the materials supplying Nut & Bolts and 3mm thick rubber insertion sheet ball complete as directed.
207207100 mm dia.8Each
208208150 mm dia.8Each
209209200 mm dia.8Each
210210Labour charge for carrying, placing in position, fitting and fixing C.I. sluice valve (with wheel & cap) C.I. refluxed valve complete with supplying bolts and nuts, 3 mm thick rubber insertion sheet etc (the tail pieces if required will be paid separately) all complete as directed (one valve and two flanged joints for following dia.
211211100 mm dia.4Each
212212150 mm dia.4Each
213213200 mm dia.4Each
214214Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering , curing etc. complete including fixing in position as directed. a) 100mm thick slab3Sqm
215215Construction of RCC Pillar for supporting pipe line in depressed areas, valley etc. of size 300 mm x 300 mm x 3500 mm average height (2000 mm below GL & Average 2500 mm above GL) of Grade M15 with 100 mm thick cement concrete base of prop. 1:3:6 (1 cement : 3 coarse sand : 6 aggregate) over flat brick soling, finished with 15 mm thick cement plastering on all exposed surfaces in prop. 1:4 (1 cement : 4 fine sand); reinforcement 10 # @ 150 mm c/c both ways at base slab of size 1000 mm x 1000 mm x 300 mm, 10 Nos. 12 # verticals in the pedestal & 10 # - 3 legged stirrups @ 150 mm c/c. including supply of all labour and materials, all complete, as directed and specified5No
216216Jointing MS pipe in line level and level by electric arc welding (butt) in three run making grooves of V shape by electric grinder and welding with Vordin 3.15/ 4.00 mm welding arc welding rod including supply of welding road providing power etc all complete as directed by the Executive Engineer In charge.6080.7CM
217217Outside coating of pipe line by approx paint in two coats over a coat painting of Johnson & Nicholson as directed59.3Sqm
218218Construction of Valve Chamber of inside measurement 1000mm x 1000mmx 1600mmhigh(1500mm below 300mm above GL) with 100mm thick cement concrete base of prop. 1:3:6 (1 cement : 3 coarse sand: 6 aggregates) over flat brick soling, 345mm thick brick wall in cement mortar in prop. 1:4 (1 cement: 4 fine sand) finished with 15mm thick cement plastering on complete inside walls and floor & upto 0.5m from top on outside walls in prop. 1:4 (1 cement: 4 fine sand); 150mm thick RCC Pit cover in prop. 1:1.5:3 ( 1 cement: 1.5 coarse sand: 3 aggregate) with double layer reinforcing mesh of 16mm dia TMT bars @125 c/c both ways, including supply of all labour and materials, all complete as directed and specified.5each
219219Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:\nFoundation, footings, bases of columns, pile cap, raft and mass concrete works etc.\n(a) Using 38mm thick plank.0.9Sqm
220220Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) \na) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL\n(i) TMT Corrosion resistant steel (CRS) reinforcement bar\n1.1Qntl
221221Providing and laying plain/reinforced cement concrete works cement, coarse sand & 20mm downgraded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) \n(I) Using Mixer Machine\n(A) In substructure up to plinth level\nFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.\nN) Without using admixture, plasticizer\nb) M20 grade concrete or Prop. 1:1.5:3.0.3CM
22222215 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. \nA) On rough side\nb) In cement mortar 1:46.4Sqm

AI Tender Summary

OUR REF NO 26500445
AUTHORITY Government Departments
TENDER VALUE 1.88 Crore
LAST DATE 20-01-2021
Authority
Authority Name Assam Urban Water Supply And Sewerage Board
Work Description Execution , Testing And Commissioning Of Balance Work For Lakhipur ( Goalpara ) Town Water Supply Scheme Execution , Testing And Commissioning Of Balance Work For Lakhipur ( Goalpara ) Town Water Supply Scheme Under Dhubri Division Of Assam Urban Water Supply Sewerage Board
Basic Detail
Tender No NIT 06 of 2020-21 dated 05-01-2021
Bidding Type Tender
Location
City Lakhipur, Goalpara District, Assam
State Assam
Key Dates
Publish Date 06 Jan 2021
Submission Date 20 Jan 2021
Open Date 20 Jan 2021
Finance
Tender Value 1.88 Crore
Tender Fee 3000
EMD 3.77 Lakhs
Exemption Not Available
Document List
AA717A98-B974-47D8-A4A3-359133D5A07C.html
Tendernotice_1.pdf
BidDocmentIFBno06of2020-21.pdf
BOQ_30883.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 06, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 20, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 20, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

AA717A98-B974-47D8-A4A3-359133D5A07C.html

pdf

Tendernotice_1.pdf

pdf

BidDocmentIFBno06of2020-21.pdf

xls

BOQ_30883.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders