Construction Of Modular Operation Theatre At District Hospital Tirur In Malappuram Dist, Tirur, Malappuram-Kerala

Wapcos Limited has published Construction Of Modular Operation Theatre At District Hospital Tirur In Malappuram Dist. Submission Date for this Tender is 16-01-2021. Modular Operation Theater Tenders in Tirur, Malappuram Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

26483728
Construction Of Modular Operation Theatre At District Hospital Tirur In Malappuram Dist
Open Tender
Indian
Kerala
Tirur, Malappuram
16-01-2021

Tender Details

Construction Of Modular Operation Theatre At District Hospital Tirur In Malappuram Dist

Key Value

Document Fees
INR 2800 /-
EMD
INR 50000.0 /-
Tender Value
INR 81.16 Lakhs /-

BOQ Items

Work Name :CONSTRUCTION OF MODOULAR OPERATION THEATRE AT DISTRICT HOSPITAL TIRUR IN MALAPPURAM DIST.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 MODULAR OPERATION THEATRE BI01010001010000000000000515BI0100001113
2 1.01 od123696/2020_2021 : Providing, Fixing, Supply & installation of Pre Fabricated Modular Operation Theatre with 50mm thick EGP Puff Panel of 0.8mm EGP sheet on front side and 0.8mm PCGI Panel on back side. Filling of all joints and cavities with epoxy filler and sanded flush to provide a seamless finish .Applied with minimum three coats of Antibacterial & Antifungal paint ,wall glaze or equivalent to a minimum dry film thickness of 300 microns having overlap floor covering ,ceiling system and door frames by 25mm to provide a continous sealed surface <br>MAKE-SAIL/JINDAL BI01010001010000000000000515BI0100001114 200 sqm
3 1.02 od123772/2020_2021 : Providing and Installing of Distribution Board with MCB and ELCB, Electrical Wiring inside Operation Theater including Sockets & Switches<br>MAKE: MEDFLOW/SCHEMATIC BI01010001010000000000000515BI0100001115 2 each
4 1.03 od123773/2020_2021 : Providing supply and installation of storage unit - ( 1700 x 900 x 350 ) made of 1.5 mm thick SS Sheet with sterile surface coating ,complete with all accessories.<br>MAKE: MEDFLOW/BALAJI/ALTOS BI01010001010000000000000515BI0100001116 2 each
5 1.04 od123774/2020_2021 : 3 bay Surgical Scrub Sink made out of 304 Stainless Steel & seamless welded construction polished to a satin finish which is operated manually <br>MAKE: MEDFLOW/BALAJI/ALTOS BI01010001010000000000000515BI0100001117 1 each
6 1.05 od123775/2020_2021 : Swivel pendant with 1000 mm long arm with rotational movements having weight carrying capacity of the arm will not be less than 100 Kgs, one monitor shelf and provision for six electrical sockets 5/15 Amp, and gas outlets.<br>MAKE: ALTOS/MEDFLOW BI01010001010000000000000515BI0100001118 2 each
7 1.06 od123776/2020_2021 : Recess mounted IP54 protocol, non-hygroscopic peripheral lights for clean room application each set having LED Lights with dimmer control (Suitable for Clean room Class 100 application)<br>MAKE: WIPRO/PHILLIPS BI01010001010000000000000515BI0100001119 16 each
8 1.07 od123777/2020_2021 : Providing, Fixing, Supply and Installation of Operating Writing List Board of size ( 948mm x 648mm )<br>MAKE: DIGILINE/ALTOS BI01010001010000000000000515BI0100001120 2 each
9 1.08 od123778/2020_2021 : Providing, Fixing, Supply and Installation of seamless Lead mat static conductive flooring system , 2 mm thick ,with perfectly curved flash covings,all joints welded as per the colour and pattern approved by hospital.<br>MAKE: TARKETT/GERFLOR/ARMSTRONG BI01010001010000000000000515BI0100001121 74 sqm
10 1.09 od123780/2020_2021 : Providing, Fixing, Supply, Installation, Testing and Commissioning of Two Plate dimmable X-Ray viewing screen (948mm x 648mm) designed to provide a high level of control luminance without flicker. (Dimming Range 3-100%) <br>MAKE: DIGILINE/ ALTOS BI01010001010000000000000515BI0100001122 2 each
11 1.1 od123781/2020_2021 : Providing, Fixing, Supply, Installation, testing and Commissioning of Membrane type Surgeon Control Panel( 6 services ) ,mounted flush in the theatre wall alongwith Distribution Board comprising of the following : -1 No Day time Clock (Digital) -1 No Lapse Time Clock (Digital) -1 Hands free telephone -1 No Medical Gas Alarm -1 Set indicator for temperature & humdity display<br>-1 Set Pressure Difference Indicator -1 Peripheral Lighting On/Off with dimming Control<br>MAKE: DIGILINE/ALTOS BI01010001010000000000000515BI0100001123 2 each
12 1.11 od123782/2020_2021 : Supply , installation, Testing and Commissioning of Air Supply (2400 mm X 2400 mm) ceiling for air distribution system complete with 6 Nos. HEPA Filters ( efficiency 99.97% down to 0.3 microns ) complete.For Distribution of supply/ return air flow as follow. a) 30% of return air exhausted through blower near the AHU. b). 30% Fresh air will be mixed in mixing chamber.c). 70% cooling air will be circulating from AHU.<br>MAKE: BALAJI/MEDFLOW/ALTOS BI01010001010000000000000515BI0100001124 2 each
13 1.12 od123783/2020_2021 : Providing, Fixing, Supply, Installation, and Commissioning of Manually Operated Hermetically Sealing Sliding , having 304 grade Stainless Steel on both sides that could withstand high abrasion , vision panels (300x300mm) , for smooth sliding .The door moves on nylon wheels within an single piece aluminium extruded track. Size is (1500 x 2100 ) <br>MAKE: METAFLEX/REBBONE/ALTOS BI01010001010000000000000515BI0100001125 2 each
14 1.13 od123831/2020_2021 : Providing, Fixing, Supply and Installation and Commissioning of proper Pressure Relief Dampers having multi 304 graded stainless steel blades for maintaining the positive pressure inside the operation theatre<br>MAKE: MEDFLOW/BALAJI/ALTOS BI01010001010000000000000515BI0100001126 2 each
15 2 NON-MODULAR OPERATION THEATRE BI01010001010000000000000515BI0100001127
16 2.01 od123883/2020_2021 : Providing and Installing of Distribution Board with MCB and ELCB, Electrical Wiring inside Operation Theater including Sockets & Switches<br>MAKE: MEDFLOW/SCHEMATIC BI01010001010000000000000515BI0100001128 4 sqm
17 2.02 od123884/2020_2021 : Supply, Installation, Testing and Commisioning of PCGI ( Powder Coated Galvanized Iron ) Swing doors for Operation Theatres<br>MAKE: METAFLEX/REBBONE/ALTOS BI01010001010000000000000515BI0100001129 4 each
18 2.03 od123885/2020_2021 : 1 bay Surgical Scrub Sink made out of 304 Stainless Steel & seamless welded construction polished to a satin finish which is operated manually <br>MAKE: MEDFLOW/BALAJI/ALTOS BI01010001010000000000000515BI0100001130 1 each
19 2.04 od123886/2020_2021 : Providing, Fixing, Supply and Installation of seamless Lead mat static conductive flooring system , 2 mm thick ,with perfectly curved flash covings,all joints welded as per the colour and pattern approved by hospital.<br>MAKE: TARKETT/GERFLOR/ARMSTRONG BI01010001010000000000000515BI0100001131 113 sqm
20 2.05 od123887/2020_2021 : Recess mounted IP54 protocol, non-hygroscopic peripheral lights for clean room application each set having LED Lights with dimmer control (Suitable for Clean room Class 100 application)<br>MAKE: WIPRO/PHILLIPS BI01010001010000000000000515BI0100001132 20 each
21 2.06 od123888/2020_2021 : Providing, Fixing, Supply, Installation, testing and Commissioning of Membrane type Surgeon Control Panel( 6 services ) ,mounted flush in the theatre wall alongwith Distribution Board comprising of the following : -1 Peripheral Lighting On/Off with dimming Control<br>MAKE: DIGILINE/ALTOS BI01010001010000000000000515BI0100001133 4 each
22 2.07 od123889/2020_2021 : Supply and Installation of seamless 1 mm thick Vinyl Wall Covering,with all joints welded as per the colour and pattern approved by hospital.<br>MAKE: TARKETT/GERFLOR/ARMSTRONG BI01010001010000000000000515BI0100001134 214 sqm
23 2.08 od123890/2020_2021 : Supply & installation of Pre Fabricated Modular Operation Theatre Ceiling with 50mm thick EGP Puff Panel of 0.8mm EGP sheet on front side and 0.8mm PCGI Panel on back side. Filling of all joints and cavities with epoxy filler and sanded flush to provide a seamless finish .Applied with minimum three coats of Antibacterial & Antifungal paint ,wall glaze or equivalent to a minimum dry film thickness of 300 microns having overlap floor covering ,ceiling system and door frames by 25mm to provide a continous sealed surface <br>MAKE-SAIL/JINDAL BI01010001010000000000000515BI0100001135 110 sqm
24 3 CIVIL AND INTERIOR WORKS FOR OT COMPLEX BI01010001010000000000000515BI0100001136
25 3.01 od123922/2020_2021 : Supply and Installation of Gypsum Ceiling for Corridor, Preperation Room, Recovery Room, Dr. Rest Room, Change Rooms, Record Room and Dining Room BI01010001010000000000000515BI0100001137 225 sqm
26 3.02 21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) BI01010001010000000000000515BI0100001138 400 kg
27 3.03 21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) BI01010001010000000000000515BI0100001139 50 kg
28 3.04 21.13 : Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete BI01010001010000000000000515BI0100001140 15 each
29 3.05 21.16.2 : Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-Charge.Powder coated minimum thickness 50 micron aluminium BI01010001010000000000000515BI0100001141 40 no
30 3.06 21.2.2 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides BI01010001010000000000000515BI0100001142 100 sqm
31 3.07 21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness BI01010001010000000000000515BI0100001143 25 sqm
32 3.08 9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. BI01010001010000000000000515BI0100001144 10 no
33 3.09 14.46 : Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. BI01010001010000000000000515BI0100001145 225 sqm
34 3.1 13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. BI01010001010000000000000515BI0100001146 225 sqm
35 3.11 13.83.2 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats BI01010001010000000000000515BI0100001147 225 sqm
36 4 Civil/Plumbing works BI01010001010000000000000515BI0100001148
37 4.01 15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar BI01010001010000000000000515BI0100001149 1 cum
38 4.02 15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below BI01010001010000000000000515BI0100001150 10 each
39 4.03 15.56 : Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. BI01010001010000000000000515BI0100001151 50 sqm
40 4.04 15.57 : Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge BI01010001010000000000000515BI0100001152 28 sqm
41 4.05 15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved BI01010001010000000000000515BI0100001153 40 cum
42 4.06 od123954/2020_2021 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 6Kgf/cm2 - External work- Exposed on wall BI01010001010000000000000515BI0100001154 20 metre
43 4.07 od123955/2020_2021 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 6Kgf/cm2 - External work- Exposed on wall BI01010001010000000000000515BI0100001155 10 metre
44 5 Electrical Works inside OT Complex BI01010001010000000000000515BI0100001156
45 5.01 1.17.1 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm BI01010001010000000000000515BI0100001157 100 metre
46 5.02 1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm BI01010001010000000000000515BI0100001158 100 metre
47 5.03 1.17.11 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm BI01010001010000000000000515BI0100001159 220 metre
48 5.04 1.17.20 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm BI01010001010000000000000515BI0100001160 40 metre
49 5.05 1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm BI01010001010000000000000515BI0100001161 300 metre
50 5.06 1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm BI01010001010000000000000515BI0100001162 150 metre
51 5.07 1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch BI01010001010000000000000515BI0100001163 5 each
52 5.08 1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch BI01010001010000000000000515BI0100001164 2 each
53 5.09 1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet BI01010001010000000000000515BI0100001165 5 each
54 5.1 1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet BI01010001010000000000000515BI0100001166 2 each
55 5.11 1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) BI01010001010000000000000515BI0100001167 5 each
56 5.12 1.27.3 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) BI01010001010000000000000515BI0100001168 2 each
57 5.13 1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) BI01010001010000000000000515BI0100001169 2 each
58 5.14 1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module BI01010001010000000000000515BI0100001170 3 each
59 5.15 1.28.3 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module BI01010001010000000000000515BI0100001171 2 each
60 5.16 1.28.4 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module BI01010001010000000000000515BI0100001172 2 each
61 5.17 1.34 : Supplying and fixing brass batten/ angle holder including connection etc. as required. BI01010001010000000000000515BI0100001173 5 each
62 5.18 1.57 : Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. lCD BI01010001010000000000000515BI0100001174 2 each
63 5.19 90.3.20.3 : Supply & installation of light fittings on TW round block\t<br>\t\t\t\t\t\nSupply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. BI01010001010000000000000515BI0100001175 35 each
64 5.2 2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door BI01010001010000000000000515BI0100001176 1 each
65 5.21 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole BI01010001010000000000000515BI0100001177 35 each
66 5.22 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps BI01010001010000000000000515BI0100001178 1 each
67 5.23 2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps BI01010001010000000000000515BI0100001179 1 each
68 5.24 2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual \n current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps BI01010001010000000000000515BI0100001180 1 each
69 5.25 1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC\ninsulated copper conductor single core cable in surface / recessed medium class PVC conduit,\nwith modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS\nPVC insulated copper conductor single core cable etc as required.Group C BI01010001010000000000000515BI0100001181 45 point
70 5.26 od124001/2020_2021 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator 6 way (4 + 18), Double door BI01010001010000000000000515BI0100001182 2 no
71 5.27 od124002/2020_2021 : Supply and installation testing and commissioning of ceiling fan of 1200mm sweep, BLDC type, 5 star rating complete with 300mm down rod, canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C. BI01010001010000000000000515BI0100001183 7 each
72 6 MODULAR OPERATION THEATRE HVAC WORKS BI01010001010000000000000515BI0100001184
73 6.01 od265554/2020_2021 : Supply, Installation, testing &amp; commissioning of factory built Ceiling Suspended/Floor mounted DX double Skin horizontal/vertical Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain SS sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch &amp; tube thickness not less than 0.5mm),Cooling coil of 8 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &amp; 5 micron fine filters, mixing box with fresh air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , strip heater capacity 3x1.5KW, germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used&lt;br&gt;Horizontal Ceiling Suspended /Floor Mounted AHU &lt;br&gt;6 TR/ 2900 CFM/ 8 RD/ 150 mm TSP BI01010001010000000000000515BI0100001185 2 no
74 6.02 od266026/2020_2021 : Supply, Installation testing and commissioning of the air cooled outdoor unit (condensing unit). It shall be of corrosion resistant galvanized powder coated or equivalent sheet steel assembly installed on suitable vibration isolators and comprising of energy efficient Scroll compressor with controls such as thermal protector, HP/LP cutouts, Pressure relief valve and condenser fan unit; the units shall have integral refrigerant copper piping within compressor and condenser and accessories such as refrigerant shut off valves at compressor / compressors and liquid refrigerant outlet if required &amp; filter dryer, with R 410 A refrigerant; Cooling fans shall have protective metal frame.The Outdoor units within Sunshade and on Terrace shall be installed on MS angle iron frame duly corrossion proof painted and supplied as welded structure which shall be securely grouted on floor and duly painted with anti-corrosive paint; the frame shall be isolated from floor through adequate vibration isolation; Price shall be inclusive of all required MS supports.&lt;br&gt;Rates shall be including supply and commissioning of matching rated factory supplied Electrical Starter &amp; Control Panel. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 deg C ambient temperature without tripping. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5&lt;br&gt;Note: Control cables connecting the IDU and the ODU &amp; 6 SMG GI wire loop Earthing shall be included in Split unit cost and on lot basis and run on the Power cable trays with adequate supports and electrical protection.&lt;br&gt;6TR - Condensing unit BI01010001010000000000000515BI0100001186 2 no
75 6.03 od266027/2020_2021 : Supply, installation, balancing and commissioning of factory fabricated Aluminium sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows,splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required&lt;br&gt;Aluminium Ducting 20G BI01010001010000000000000515BI0100001187 55 sqm
76 6.04 od266028/2020_2021 : Supply, installation, balancing and commissioning of factory fabricated Aluminium sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows,splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required&lt;br&gt;Aluminium Ducting 22G BI01010001010000000000000515BI0100001188 115 sqm
77 6.05 od266044/2020_2021 : SITC of Powder Coated Extruded Aluminium return Air Grill with horizontal fixed bars and end flanges BI01010001010000000000000515BI0100001189 2 sqm
78 6.06 od266045/2020_2021 : SITC of Fresh Air arrangements with bird screen and VCD BI01010001010000000000000515BI0100001190 2 L.S
79 6.07 od266046/2020_2021 : SITC of Extract Air arrangements with Louvers, back draft dampers and VCD&apos;s BI01010001010000000000000515BI0100001191 2 L.S
80 6.08 od266047/2020_2021 : SITC of Powder Coated Extruded Aluminium Volume Control Dampers complete with flanges, channels &amp; control levers suitable for duct mounting BI01010001010000000000000515BI0100001192 2 sqm
81 6.09 od266048/2020_2021 : Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber(Class &quot;O&quot;) insulation on existing duct after applying suitable adhesive for Nitrile rubber. Density of insulation material shall be between 40 to 55 Kg/m3.The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.&lt;br&gt;9 mm thick Anti Microbial Nitrile Rubber insulation (Duct run in A/c area) BI01010001010000000000000515BI0100001193 100 sqm
82 6.1 od266049/2020_2021 : Supply &amp; fixing of 10 mm thick opencell nitrile rubber form with density 140-180kg/m3 along with antimicrobial product protection as acoustic insulation for ducts using suitable adhesive as per the recommendation of the insulation manufacturer .&lt;br&gt; BI01010001010000000000000515BI0100001194 20 sqm
83 6.11 od266051/2020_2021 : SITC of Flexible Connection made out of fire resistant flexible double canvas sleeve. BI01010001010000000000000515BI0100001195 2 set
84 6.12 od266052/2020_2021 : Supply, installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for DX AHU system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with class-O closed cell elastomeric nitrile rubber tubular sleeve of 19mm thickness for suction and liquid lines, all accessories as per specification etc. as required. BI01010001010000000000000515BI0100001196 20 metre
85 6.13 od267302/2020_2021 : Supply, installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for DX AHU system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with class-O closed cell elastomeric nitrile rubber tubular sleeve of 19mm thickness for suction and liquid lines, all accessories as per specification etc. as required. (Liquid Line- 6TR) BI01010001010000000000000515BI0100001197 20 metre
86 6.14 od267308/2020_2021 : Supply,Laying and Fixing of Power and Control cabling between indoor and outdoor units with required specification BI01010001010000000000000515BI0100001198 60 metre
87 6.15 od267329/2020_2021 : SITC of 25mm OD UPVC SCH 40 pipe with 9mm thick aniti microbial nitrile rubber sleeve insulation for condensate drain piping of AHUs to the nearest drain point. BI01010001010000000000000515BI0100001199 30 metre
88 6.16 od267342/2020_2021 : Supply, Installation Testing and Commissioning of Duct Inline Exhaust Fans 220cfm, 10mm static. BI01010001010000000000000515BI0100001200 2 no
89 6.17 od267348/2020_2021 : SITC of Control panel for AHU including bypass switch BI01010001010000000000000515BI0100001201 2 no
90 6.18 od268185/2020_2021 : Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber(Class &quot;O&quot;) insulation on existing duct after applying suitable adhesive for Nitrile rubber. Density of insulation material shall be between 40 to 55 Kg/m3.The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.&lt;br&gt;19 mm thick Anti Microbial Nitrile Rubber insulation (Duct run in non-A/c area) BI01010001010000000000000515BI0100001202 40 sqm
91 7 NON-MODULAR OPERATION THEATRE HVAC WORKS BI01010001010000000000000515BI0100001203
92 7.01 od268115/2020_2021 : Supply, Installation, testing &amp; commissioning of factory built Ceiling Suspended/Floor mounted DX double Skin horizontal/vertical Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain AL sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch &amp; tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &amp; 5 micron fine filters, mixing box with fresh air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used&lt;br&gt;Horizontal Ceiling Suspended /Floor Mounted AHU &lt;br&gt;4.5 TR/ 1800 CFM/ 6 RD/ 75 mm TSP BI01010001010000000000000515BI0100001204 2 no
93 7.02 od268116/2020_2021 : Supply, Installation testing and commissioning of the air cooled outdoor unit (condensing unit). It shall be of corrosion resistant galvanized powder coated or equivalent sheet steel assembly installed on suitable vibration isolators and comprising of energy efficient Scroll compressor with controls such as thermal protector, HP/LP cutouts, Pressure relief valve and condenser fan unit; the units shall have integral refrigerant copper piping within compressor and condenser and accessories such as refrigerant shut off valves at compressor / compressors and liquid refrigerant outlet if required &amp; filter dryer, with R 410 A refrigerant; Cooling fans shall have protective metal frame.The Outdoor units within Sunshade and on Terrace shall be installed on MS angle iron frame duly corrossion proof painted and supplied as welded structure which shall be securely grouted on floor and duly painted with anti-corrosive paint; the frame shall be isolated from floor through adequate vibration isolation; Price shall be inclusive of all required MS supports.&lt;br&gt;Rates shall be including supply and commissioning of matching rated factory supplied Electrical Starter &amp; Control Panel. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 deg C ambient temperature without tripping. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5&lt;br&gt;Note: Control cables connecting the IDU and the ODU &amp; 6 SMG GI wire loop Earthing shall be included in Split unit cost and on lot basis and run on the Power cable trays with adequate supports and electrical protection.&lt;br&gt;4.5TR - Condensing unit BI01010001010000000000000515BI0100001205 2 no
94 7.03 od268117/2020_2021 : Supply, Installation, testing &amp; commissioning of factory built Ceiling Suspended/Floor mounted DX double Skin horizontal/vertical Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain AL sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch &amp; tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &amp; 5 micron fine filters, mixing box with fresh air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used&lt;br&gt;Horizontal Ceiling Suspended /Floor Mounted AHU &lt;br&gt;3 TR/ 1350 CFM/ 6 RD/ 75 mm TSP BI01010001010000000000000515BI0100001206 2 no
95 7.04 od268119/2020_2021 : Supply, Installation testing and commissioning of the air cooled outdoor unit (condensing unit). It shall be of corrosion resistant galvanized powder coated or equivalent sheet steel assembly installed on suitable vibration isolators and comprising of energy efficient Scroll compressor with controls such as thermal protector, HP/LP cutouts, Pressure relief valve and condenser fan unit; the units shall have integral refrigerant copper piping within compressor and condenser and accessories such as refrigerant shut off valves at compressor / compressors and liquid refrigerant outlet if required &amp; filter dryer, with R 410 A refrigerant; Cooling fans shall have protective metal frame.The Outdoor units within Sunshade and on Terrace shall be installed on MS angle iron frame duly corrossion proof painted and supplied as welded structure which shall be securely grouted on floor and duly painted with anti-corrosive paint; the frame shall be isolated from floor through adequate vibration isolation; Price shall be inclusive of all required MS supports.&lt;br&gt;Rates shall be including supply and commissioning of matching rated factory supplied Electrical Starter &amp; Control Panel. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 deg C ambient temperature without tripping. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5&lt;br&gt;Note: Control cables connecting the IDU and the ODU &amp; 6 SMG GI wire loop Earthing shall be included in Split unit cost and on lot basis and run on the Power cable trays with adequate supports and electrical protection.&lt;br&gt;3TR - Condensing unit BI01010001010000000000000515BI0100001207 2 no
96 7.05 od266027/2020_2021 : Supply, installation, balancing and commissioning of factory fabricated Aluminium sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows,splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required&lt;br&gt;Aluminium Ducting 20G BI01010001010000000000000515BI0100001208 21 sqm
97 7.06 od266028/2020_2021 : Supply, installation, balancing and commissioning of factory fabricated Aluminium sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows,splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required&lt;br&gt;Aluminium Ducting 22G BI01010001010000000000000515BI0100001209 70 sqm
98 7.07 od268157/2020_2021 : Supply and fixing of powder coated extruded aluminium supply and return air diffuser with aluminium volume control dampers as per specification with anti-smudge ring and removable core BI01010001010000000000000515BI0100001210 6 sqm
99 7.08 od266044/2020_2021 : SITC of Powder Coated Extruded Aluminium return Air Grill with horizontal fixed bars and end flanges BI01010001010000000000000515BI0100001211 1 sqm
100 7.09 od268164/2020_2021 : SITC of Fresh Air arrangements with bird screen and VCD BI01010001010000000000000515BI0100001212 4 L.S
101 7.1 od268165/2020_2021 : SITC of Extract Air arrangements with Louvers, back draft dampers and VCD&apos;s BI01010001010000000000000515BI0100001213 1 L.S
102 7.11 od266047/2020_2021 : SITC of Powder Coated Extruded Aluminium Volume Control Dampers complete with flanges, channels &amp; control levers suitable for duct mounting BI01010001010000000000000515BI0100001214 1 sqm
103 7.12 od266048/2020_2021 : Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber(Class &quot;O&quot;) insulation on existing duct after applying suitable adhesive for Nitrile rubber. Density of insulation material shall be between 40 to 55 Kg/m3.The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.&lt;br&gt;9 mm thick Anti Microbial Nitrile Rubber insulation (Duct run in A/c area) BI01010001010000000000000515BI0100001215 50 sqm
104 7.13 od268185/2020_2021 : Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber(Class &quot;O&quot;) insulation on existing duct after applying suitable adhesive for Nitrile rubber. Density of insulation material shall be between 40 to 55 Kg/m3.The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.&lt;br&gt;19 mm thick Anti Microbial Nitrile Rubber insulation (Duct run in non-A/c area) BI01010001010000000000000515BI0100001216 50 sqm
105 7.14 od266051/2020_2021 : SITC of Flexible Connection made out of fire resistant flexible double canvas sleeve. BI01010001010000000000000515BI0100001217 4 set
106 7.15 od268260/2020_2021 : Supply, installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for DX AHU system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with class-O closed cell elastomeric nitrile rubber tubular sleeve of 19mm thickness for suction and liquid lines, all accessories as per specification etc. as required.Suction line (4.5TR) BI01010001010000000000000515BI0100001218 14 metre
107 7.16 od268261/2020_2021 : Supply, installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for DX AHU system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with class-O closed cell elastomeric nitrile rubber tubular sleeve of 19mm thickness for suction and liquid lines, all accessories as per specification etc. as required. (Liquid Line- 4.5TR) BI01010001010000000000000515BI0100001219 14 metre
108 7.17 od268262/2020_2021 : Supply, installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for DX AHU system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with class-O closed cell elastomeric nitrile rubber tubular sleeve of 19mm thickness for suction and liquid lines, all accessories as per specification etc. as required.Suction line (3TR) BI01010001010000000000000515BI0100001220 4 metre
109 7.18 od268263/2020_2021 : Supply, installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for DX AHU system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with class-O closed cell elastomeric nitrile rubber tubular sleeve of 19mm thickness for suction and liquid lines, all accessories as per specification etc. as required. (Liquid Line- 3TR) BI01010001010000000000000515BI0100001221 4 metre
110 7.19 od267329/2020_2021 : SITC of 25mm OD UPVC SCH 40 pipe with 9mm thick aniti microbial nitrile rubber sleeve insulation for condensate drain piping of AHUs to the nearest drain point. BI01010001010000000000000515BI0100001222 40 metre
111 7.2 od267342/2020_2021 : Supply, Installation Testing and Commissioning of Duct Inline Exhaust Fans 220cfm, 10mm static. BI01010001010000000000000515BI0100001223 2 no
112 7.21 od268264/2020_2021 : Supply, Installation Testing and Commissioning of Duct Inline Exhaust Fans 100cfm, 10mm static. BI01010001010000000000000515BI0100001224 2 no
113 7.22 od267308/2020_2021 : Supply,Laying and Fixing of Power and Control cabling between indoor and outdoor units with required specification BI01010001010000000000000515BI0100001225 45 metre
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail