}

Repair/Maintenance Of Water Supply Installation Including Rewinding Of Motors And Allied Accessories , Ci And Gi Pipe Lines And Connected Works And Lt Poles , Acsr Conductor , Transformer , Lt Panel Boards And Accessories At Rajbari Area Dimapur Unde, Rangapahar-Nagaland

Military Engineer Services-MES has published Repair/Maintenance Of Water Supply Installation Including Rewinding Of Motors And Allied Accessories , Ci And Gi Pipe Lines And Connected Works And Lt Poles , Acsr Conductor , Transformer , Lt Panel Boards And Accessories At Rajbari Area Dimapur Unde. Submission Date for this Tender is 23-01-2021. Electrical Maintenance Tenders in Rangapahar Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

26483457
Corrigendum : Repair/Maintenance Of Water Supply Installation Including Rewinding Of Motors And Allied Accessories , Ci And Gi Pipe Lines And Connected Works And Lt Poles , Acsr Conductor , Transformer , Lt Panel Boards And Accessories At Rajbari Area Dimapur Unde
Open Tender
Indian
Nagaland
Rangapahar
23-01-2021

Tender Details

Repair / Maintenance Of Water Supply Installation Including Rewinding Of Motors And Allied Accessories , Ci And Gi Pipe Lines And Connected Works And Lt Poles , Acsr Conductor , Transformer , Lt Panel Boards And Accessories At Rajbari Area Dimapur Under Age E / M

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Jan-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-01-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 47500.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/MAINT OF WATER SUPPLY INSTALLATION INCLUDING REWINDING OF MOTORS AND ALLIED ACCESSORIES, CI AND GI PIPE LINES AND CONNECTED WORKS AND LT POLES, ACSR CONDUCTOR, TRANSFORMER, LT PANEL BOARDS AND ACCESSORIES AT RAJBARI AREA DIMAPUR UNDER AGE E/M OF GE 868 EWS.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in trenches n exc 1.5 mtr wide and n exc 1.5m in depth for layiung of water supply pipe line etc n exc 10 Sqm on plan and getting out soft/loose soil. 135.6 Cum
2 2 Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil. 210.75 Cum
3 3 Removing ex avated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point 55 Cum
4 4 Taking up or down exting unserviceable GI or steel tubing for replacing length/fittings etc with new of size 15 mm bore. 75 RM
5 5 All as per item No. 04 above here-in-before but of size 20 dia mm bore 150 RM
6 6 All as per item No. 04 above here-in-before but of size 25 dia mm bore. 75 RM
7 7 All as per item No. 04 above here-in-before but of size 40 mm dia / 50 mm/80 mm dia bore. 72 RM
8 8 M&L for GI tubing medium grade with all fittings laid in trenches or fixed on walls or on floors etc.including connections in position of size 15 mm bore. 75 RM
9 9 All as per item No. 08 above here-in-before but of size 20 dia mm bore 150 RM
10 10 All as per item No. 08 above here-in-before but of size 25 dia mm bore. 75 RM
11 11 All as per item No. 08 above here-in-before but of size 40 dia mm bore. 18 RM
12 12 All as per item No. 08 above here-in-before but of size 50 dia mm bore. 24 RM
13 13 All as per item No. 08 above here-in-before but of size 80 dia mm bore. 30 RM
14 14 M&L for cutting existing steel water tubing in position for alteration or addition for replacing damaged length/fittings etc of following size 15 mm bore. 15 Each
15 15 All as per item No. 14 above here-in-before but of size 20 dia mm bore 12 Each
16 16 All as per item No. 14 above here-in-before but of size 25 dia mm bore. 12 Each
17 17 All as per item No. 14 above here-in-before but of size 50 dia mm bore. 10 Each
18 18 M&L screwing existing steel water tubing in position for alteration or additionincl and M&L for insertion of reqd fitting such as socket, union, nipple etc by replacing damaged length etc of following size of 15 mm dia bore. 15 Each
19 19 All as per item No. 18 above here-in-before but of size 20 dia mm bore. 12 Each
20 20 All as per item No. 18 above here-in-before but of size 25 dia mm bore. 12 Each
21 21 All as per item No. 18 above here-in-before but of size 50 dia mm bore. 10 Each
22 22 M&L for cutting cast iron pipes in position for insertion of tees, branches or replacing damaged length etc of size 80 mm bore. 4 Each Job
23 23 All as per item No. 22 above here-in-before but of size 100 dia mm bore. 3 Each Job
24 24 All as per item No. 22 above here-in-before but of size 150 dia mm bore. 2 Each Job
25 25 Taking up cast iron water main (including all fittings), with spigot and socketed ends jointed with run lead joints including burning out lead of joints and collecting run lead for re-use, cleaning serviceable pipe internally/externally for re-use, stacking properly in safe custody in storeyard of AGE E/M and removing unserviceable pipe from site complete, all as specified and directed for 80 mm dia bore pipe.\n(Note :-Excavatuion and earth work shall be measured and paid separately) 33 RM
26 26 All as per item No. 25 above here-in-before but of size 100 dia mm bore. 35 RM
27 27 All as per item No. 25 above here-in-before but of size 150 dia mm bore 50.5 RM
28 28 Laying only in trenches old serviceable cast iron pipe any class (obtained from item No. 25 here-in-before),with spigot and socketed ends, jointed with rubber tyton or run lead joints, complete, all as specified and directed for 80 mm dia bore Note : (i) Rubber tyton or run lead joints of pipes shall be measured and paid separately under respective items here-in-after.\n(ii) Cast iron fittings/specials shall be measured and paid separately under respective items here-in-after. 33 RM
29 29 All as per item No. 28 above here-in-before but of size 100 dia mm bore. 35 RM
30 30 All as per item No. 28 above here-in-before but of size 150 dia mm bore. 50.5 RM
31 31 Supply, laying in trenches, jointing/ connecting and testing CI pipe in any length, conforming to IS with spigot and socketed ends, centrifugally cast type, jointed with run lead joints complete, all as specified and directed for 80 mm dia bore. \nMake : Electrosteel / Jindal/Kesoram. Note : (i) Rates quoted by tenterer including earth work work and jointing material like Rubber tyton or run lead joints,including necessary welding work etc. (ii) CI/DI fittings shall be measured and paid seperatly respective items here-in-after. 44 RM
32 32 Supply, laying in trenches, jointing/ connecting and testing Ductile iron pipe in any length, conforming to IS with spigot and socketed ends, centrifugally cast type, jointed with rubber tyton complete, ISI Marked all as specified and directed for 100 mm dia bore.\nMake : Electrosteel / Jindal/Kesoram. Note : (i) Rates quoted by tenterer including earth work work and jointing material like Rubber tyton or run lead joints,including necessary welding work etc. (ii) CI/DI fittings shall be measured and paid seperatly respective items here-in-after. 33 RM
33 33 All as per item No. 32 above here-in-before but of size 150 dia mm bore. 16.5 RM
34 34 M&L for DI fittings spigot socketed and flanged pipe such as bends, tee pieces, 'Y' junction, cross collars caps and plugs of any type or radius upto 200mm bore pipe. 100 Kg
35 35 M&L for CI fittings spigot socketed and flanged pipe such as bends, tee pieces, 'Y' junction, cross collars caps and plugs of any type or radius upto 150mm bore pipe. 125 Kg
36 36 S&F for run lead joint for spigot and socketed pipes and fittings including allied jointing material i.e. spun yarn etc, complete, all as specified and directed for 80 mm dia bore pipe. 12 Each
37 37 All as per item No. 36 above here-in-before but of size 100 dia mm bore. 10 Each
38 38 All as per item No. 36 above here-in-before but of size 150 dia mm bore 15 Each
39 39 S&F Stop cock/valve cast copper alloy screwed down high pressure with crutch butter fly handle screwed both ends for iron pipe or union of 15 mm dia bore including taking down old unserviceable stop cock as per directed. \nMake : Zolloto/ Leader/Kirloskar 15 Each
40 40 All as per item No. 39 above here-in-before but of size 20 dia mm bore. 10 Each
41 41 All as per item No. 39 above here-in-before but of size 25 dia mm bore. 5 Each
42 42 S & F in repairs for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of 25 mm dia bore . 10 Each
43 43 All as per item No. 42 above here-in-before but of size 40 dia mm bore. 8 Each
44 44 All as per item No. 42 above here-in-before but of size 50 dia mm bore. 6 Each
45 45 S&F ball brass valves ,high pressure with polythene float and flynut complete ,screwed for iron pipe or brass ferrule and fixed of size 15 mm dia bore ,including taking down old unserviceable ball valve as per directed.\nMake : Leader/Prayag/Kingston. 12 Each
46 46 All as per item No. 45 above here-in-before but of size 20 dia mm bore. 15 Each
47 47 S&F bib tap cast copper alloy with crutch or butterfly handle,screwe down ,screwed for iron pipe or for brass ferrule and fixed of following size 15 mm dia,including taking down old unserviceable bibtap as per directed.\nMake : Leader/Prayag/Kingston. 5 Each
48 48 Supply, install, connecting and testing of sluice valve, class PN- 1.6 double flanged with CI body, wheel and brass spindle and nuts etc., non rising type IS- 14846 marked including jointing materials i.e. rubber gaskets, nuts, bolts etc. including taking down old unserviceable sluice valve complete all as specified and directed complete of size 80 mm dia bore.\nMake: Kirloskar/Uppadhay/Normex 3 Each
49 49 All as per item No. 48 above here-in-before but of size 100 dia mm bore. 3 Each
50 50 All as per item No. 48 above here-in-before but of size 150 dia mm bore. 4 Each
51 51 Taking out old unserviceable butterfly valve and supply, install connecting and testing of butterfly valve , heavy duty with CI body,liver operated , suitable length of liver , ISI marked including jointing materials ie rubber gaskets, nuts bolts etc complete all as specified and directed of size 80 mm dia bore. 4 Each
52 52 All as per item No. 51 above here-in-before but of size 100 dia mm bore. 3 Each
53 53 Supply & fix in repair mechanical compression joint with rubber rings suitable for 150 mm dia/GI/DI pipe including nut,bolts & washer all as specified & directed by Engr-in-charge 2 Each (Pair)
54 54 All as per item No.53 above here-in-before but of size 100 mm dia. 1 Each (Pair)
55 55 All as per item No. 53 above here-in-before but of size 80 mm dia. 1 Each (Pair)
56 56 Repair of water supply leakage line in trench/wall including replacement of items like union,elbow ,socket ,tee and reducer etc as per site requirement ,size of pipe 15 mm dia to 20 mm dia. \nNote- (i) Rates quoted by tenderer incl Excavation and refilling. (ii) GI Fittings measured and paid seprately under relevent items. 4 Job
57 57 Repair of water supply leakage line in trench/wall including replacement of items like union,elbow ,socket ,tee and reducer etc as per site requirement ,size of pipe 25 mm dia to 40 mm dia. \nNote- (i) Rates quoted by tenderer incl Excavation and refilling. (ii) GI Fittings measured and paid seprately under relevent items. 8 Job
58 58 Repair of water supply leakage line in trench/wall including replacement of items like union,elbow ,socket ,tee and reducer etc as per site requirement ,size of pipe 50 mm dia. \nNote- (i) Rates quoted by tenderer incl Excavation and refilling. (ii) GI Fittings measured and paid seprately under relevent items. 5 Job
59 59 M / L leather sheet 4 mm thick thick using for packing of foot valves etc 1 Sqm
60 60 M / L led wool using for repairing /cocking joint of cast iron pipe as per direction of Engr-in-charge. 5 kg
61 61 M / L gland packing of sizes 6mm to 8mm for using repairing for sluice valve etc as per direction of Engr-in-charge. 2 kg
62 62 M & L for construction of brick masonary valve pit chamber 900x600x1000mm (internal dimension) with fly ash bricks, old size, built in CM 1:4, PCC 1:3:6, type C-2 as in foundation concrete bed/ floor coping and 10mm thick rendering in CM 1:4 on internal and exposed external surfaces, external plaster shall be upto 15 cm below ground level and mixed with water proofing compound @ 3% by weight of cement with and including MS cover 03 mm thick sheet with locking arrangements including excavation and earth work in soft/loose soil painting sheet cover with two coat of black bituminous paint over a coat of red oxide primer complete all as shown on drawings, specified and directed 2 EACH
63 63 M & L for construction of brick masonary valve pit chamber 1050x1050x1000mm (internal dimension) with fly ash bricks, old size, built in CM 1:4, PCC 1:3:6, type C-2 as in foundation concrete bed/ floor coping and 10mm thick rendering in CM 1:4 on internal and exposed external surfaces, external plaster shall be upto 15 cm below ground level and mixed with water proofing compound @ 3% by weight of cement with and including MS cover 03 mm thick sheet with locking arrangements including excavation and earth work in soft/loose soil painting sheet cover with two coat of black bituminous paint over a coat of red oxide primer complete all as shown on drawings, specified and directed. 3 EACH
64 64 Supply & fixing of Cast Iron NRV ISI Marked with necessary rubber packing , nuts bolts etc of size 150 mm dia bore.\nMake : Kirloskar/Upadhay/Normex 1 Each
65 65 All as per item No. 64 above here-in-before but of size 100 dia mm bore. 1 Each
66 66 Finding of any type of water lekage of pipe line upto 100 dia and Repair leakage of water line in trench including replacement any type of fitting and welding work at site and stoping leakage complete. \nNote- (i) Rates including excation , welding returning filling (ii) CI/GI Fittings measured and paid seprately under relevent items. 5 Job
67 67 Finding of any type of water lekage of CI/DI pipe line of 150 dia and Repair leakage of water line in trench including replacement any type of fitting , lead joint as per site requirement and welding work at site and stoping leakage complete . Note- (i) Rates including excavation & returing filling,welding returning filling & CI/GI Fittings. 5 Job
68 68 Supply and fixing CI ball type foot valve flanged end with necessary rubber packing nuts, bolts and washers of size 100 mm dia bore complete all as specified ISI marked and directed by Engr-in-charge. \nMake : Normex / Kirloskar / Upadhaya 1 Each
69 69 All as per item No. 68 above here-in-before but of size 150 dia mm bore. 1 Each
70 70 Supply onlyg Non return valve, both side flanged IS Marked 100 mm dia . 1 Each
71 71 Supply only pig lead of approved quality. 25 Kg
72 72 Supply only spun yarn of approved quality. 15 Kg
73 73 Supply only Ball bearing No 6308 . \nMake - NBC 2 Each
74 74 All as per item No 73 here-in-before but No 6312 \nMake - TATA, NBC, SKF 2 Each
75 75 All as per item No 73 here in before but No 6212 \nMake - TATA, NBC, SKF 3 Each
76 76 All as per item No 73 here-in-before but No 6408 \nMake - TATA, NBC, SKF 2 Each
77 77 Supply only Impeller lock nut for any pump set. 3 Each
78 78 Supply only CI gland pressure plate for pump set 3 Each
79 79 Supply only Rubber gasket 3mm to 6mm thick. 20 KG
80 80 Supply only Gland packing of different sizes(15mm, 20mm 25mm) as required. 10 KG
81 81 Supply only Nut, bolt of difference sizes. 18 KG
82 82 Supply only CI impeller for 50 HP pump set \nMake- Kirloskar / KSB 2 Each
83 83 Supply only CI impeller for 25 HP pump set. \nMake- Kirloskar or equivalent 2 Each
84 84 Supply only CI impeller for 18 HP pump set \nMake- Kirloskar or equivalent 2 Each
85 85 Supply only SS shaft for 25 HP pump. \nMake- Kirloskar or equivalent 2 Each
86 86 Supply only rubber coupling suitable for 50 HP pump 2 Each
87 87 Supply only rubber coupling suitable for 25 HP pump 2 Each
88 88 Supply only rubber coupling suitable for 18 HP pump 2 Each
89 89 Supply only FRLS PVC insulated, unsheathed cable with copper conductor of size 4 sqmm 3core,1100 volt grade, flat type \nMake - Richa/ Havells/ RR Kabel/ standard. 40 RM
90 90 Supply only FRLS PVC insulated, unsheathed cable with copper conductor of size 50 sqmm, single core,1100 volt grade, \nMake - Richa/ Havells/ RR Kabel/ standard. 33.5 RM
91 91 Supply only FASD starter of cap 50 HP, 415 V, 3 Ph \nMake- Havells, L&T,Legrand or equivalent. 1 Each
92 92 Supply only FASD starter of cap 25 HP, 415 V, 3 Ph \nMake- Havells, L&T,Legrand or equivalent. 1 Each
93 93 Supply only gun metal gate valves with iron wheel both end screwed suitable for 50mm dia GI pipe. 4 Each
94 94 All as per above item but suitable for 40mm GI pipe. 5 Each
95 95 Supply only rubber gasket for joint of 80mm dia pipe. 10 Each
96 96 All as above but of size 100mm dia pipe. 15 Each
97 97 Takingd down UNSV suction hose pipe and S&F suction hose pipe of size 100mm dia 15 mtr long 4 Roll
98 98 Taking down/disconnet to UNSV/burnt electric induction motor, transporatation to civil wksp, opening to the same and cleaning with carbonised in internal portion of motor including removing of foreign particals and re-winding to motor by using appropriate guage of super enamelled copper winding wire incl varnishing,insulation paper and re assemble to the same of and get testing refix at site size of motor 50HP. 2 Job
99 99 All as above but of size 40HP. 2 Job
100 100 All as above but of size 25HP. 2 Job
101 101 All as above but of size 18 HP. 1 Job
102 102 All as above but of size 5HP. 1 Job
103 103 All as above but of size 2HP. Submersible vertical type, 1 Job
104 104 Dismantling of old UNSV/rusted steel tubular poles 9 mtr long necessary disconnecting cables/over head condcutor and removing unserviceable pole from site complete all as specified and directed. 4 Each
105 105 M & L for Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (9m long) conforming to IS-2713 (Part-I & II) including painting of pole with two coats of aluminum paint over a coat of red oxide primer from top of the pole to 1.5m above the bottom of the pole and painting with two coats of black paint over a coat of red oxide primer upto 1.5m from bottom of the pole including numbering of poles as complete all as specified and as directed.\n(Note: Excavation, earth work and PCC shall be measured and paid separately under respective item) 4 Each
106 106 Dismantling of insulator of any type and size from existing poles after opening nuts, bolts and removing from site all as directed. 40 Each
107 107 S & F Pin type insulator, porcelain vitreous white or brown including one galvanised mild steel spindle, two galvanised iron washers and nuts, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed. 10 Each
108 108 S & F Shackle type porcelain vitreous white or brown insulator size 75mm height 90mm dia (maximum) including mild steel strips of section 31 x 3mm, washers, 12mm dia insulator bolt and nut suitable for working pressure 1100 volts grade all complete as specified and directed. 20 Each
109 109 S & F Loop type insulator, vitreous porcelain, white or brown small size with overall dimension 65mm x 90 mm and clearance of hole 16mm complete all as specified 10 Each
110 110 Supply and laying Galvanised steel wire 4.00 mm dia as continuous earth wire on over head conductor, Guard cradles on road crossing and stretching the same with required span, sag and binding the conductor with GI binding wire of approximate size and incl taking down existing UNSV earth wire all complete all as specified and directed. 0.5 Qtl
111 111 S & F LT Danger notice plate of size 20cm x 15cm made of 1.6mm thick mild steel plate, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size and including taking down the existing board complete all as specified and directed. 10 Each
112 112 Preparing surfaces of steel tubular swaged pole LT with scraping out old paint by emmery paper, caustic soda complete and painting with two coats of aluminium paint and numbering of poles with white paint on black paint base and stripping with black paint (100 mm each stripe) 3 Nos at equal distance from bottom (above PCC coping) upto a height of 1200 mm complete. 250 Each
113 113 Taking down unserviceable line separator of any size and shape PVC flat/clamp/twisted type from existing LT overhead line and supply and fixing new spacer PVC flat/clamp/twisted type LT with nuts, bolts of suitable size for fixing with existing conductor complete for the following LT overhead lines. \nMake : Denson or equivalent. 1 rm
114 113.01 (a) 2 Way 20 Each
115 113.02 (b) 3 Way 20 Each
116 113.03 (c) 4 Way 10 Each
117 114 M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 95 sq mm, 3.5 core ,Including taking down old U/S UG cable complete all as per direction . \nNOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. 200 RM
118 115 Ditto all as per item No. 114 above, but size of cable 35sqmm 3.5 core 100 RM
119 116 Ditto all as per item No. 114 above, but size of cable 10 sqmm 2 core 200 RM
120 117 Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed. 135 Cum
121 118 Ditto all as per item No. 117 above, but depth exc 1.5m and not exc. 3.0 m complete and ditto. 1 Cum
122 119 M&L for spread fine river sand in trenches complete all as specified ans as directed. \nNOTE: For measurement purpose, punned down thickness shall only be taken. 51.75 Cum
123 120 M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed 4500 Each
124 121 Supply & laying tubes ' light grade' galvanised, with all fittings, fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossing for protection of cables of size 40 mm dia bore including taking down corroded GI tubing complete all as specified and as directed. 40 RM
125 122 M & L for PCC 1:4:8, type D-2, (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. 0.5 Cum
126 123 M & L for PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. 2 Cum
127 124 M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed. 0.3 Cum
128 125 Earthing complete with galvanised steel earth plate electrode size 60 cm x 60 cmx 6 mm thick burried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, connected to galvanised iron or steel, earth strip 32 x 6 mm size by means of nuts, bolts check nuts and washers made of galvanised iron or steel, earth strip protected by galvanised iron pipe 15mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC 1:3:6 type C-1(using 20 mm graded stone aggregate), pre-cast RCC cover slab 30 cm x 30 cm x 10 cm with one lifting handle made of 8 mm dia MS bar funnel wire mesh, 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical Plate No 5 of MES Schedule Part- I and testing on completion . \n(Concrete pit shall be 20 cm to 30 cm away from main pit) including taking down the existing UNSV earth pit. 3 Each set
129 126 Earthing complete with galvanised steel earth plate electrode size 60cm x 60cmx 6mm thick burried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, connected to galvanised iron or steel, earth lead 4mm size by means of nuts, bolts check nuts and washers made of galvanised iron or steel, earth wire protected by galvanised iron pipe 15mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC 1:3:6 type C-1(using 20 mm graded stone aggregate), pre-cast RCC cover slab 30 cm x 30 cm x 10 cm with one lifting handle made of 8 mm dia MS bar funnel wire mesh, 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical Plate No 5 of MES Schedule Part- I and testing on completion . \n(Concrete pit shall be 20 cm to 30 cm away from main pit). 2 Each set
130 127 Dismantling of old unserviceable stay assembly complete and removing from site complete all as specified and directed. 2 Each set
131 128 M & L for Galvanised stay strand, 7/3.15 0.2 Qtl
132 129 S&F Stay assembly complete with all accessories with stay clamps as shown in electrical plate No 1 of SSR Part-I with using stay rod 16mm dia all complete as specified and directed.[Note :- Loop type insulator, excavation and concrete foundation shall be measured and paid separately under relevant items of Sch 'A'] 2 Each set
133 130 Dismantling of cross arms fixed on steel tubular poles carefully and removing from site complete all as specified and directed. 0.3 Qtl
134 131 Cross arms of mild steel channel or angle sections of any size and shape including clamps, back plate with bolts, nuts, washers drilled for insulator bolt, welding, bending cold or hot in any shape or size as directed and painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. 0.3 Qtl
135 132 Dismantling of overhead ACSR (Aluminium conductor steel reinforced) from existing electric pole and removing unserviceable ACSR from site complete all as directed. 1 Qtl
136 133 M&L for Aluminium conductor steel reinforced (ACSR) on overhead electric lines and stretching the same with required span sag and binding the conductor with pin/shackle insulator and jumpers with aluminium binding wire not less than 2.00 mm dia complete all as specified and directed for any size. 1 Qtl
137 134 Tightening and straightening of LT overhead line of ACSR conductor/GI wire of any size and span by disconnecting and removing from insulators and tightening the conductor by using rope, chain pulley block etc and binding the conductor on insulators with and including binding wire and jumpers of ACSR complete all as directed by the Engr-in-Charge.\n(Each conductor will be measured and paid separately) 1500 RM
138 135 Cutting / trimming of tree branches and creepers which are touching of overhead lines / pole and disposal of waste timber and tree branches n.exc 50 mtrs without dismantling/ damaging of ACSR conductor complete all as specified and as directed. 2000 RM
139 136 Disconnecting electrical connection, dismantling and taking down old unsv ACSR jumpers (PVC insulated/ bare conductor) any size and type including supply and fixing of new jumpers with PVC insulated 12 KV volt grade ACSR upto 1.5m length and winding with insulators or ACSR conductor with suitable size wire complete all as specified and as directed. 15 Job
140 137 Disconnecting HT/ LT side electrical connection carefully exisitng 11 KVA/ 433 volt step down transformer of any capacity, draining out and re-filling of exisiting tranformer oil after filtration dehydration and measuring the di-electric strength which should not be less than 40 KV including re-installation of transformer satiesfaactory on its original position connecting, testing and commissioning complete all as specified and as directed. 350 Ltrs
141 138 M&L for filling of new tranformer oil having di-electric strength not less 50 KV complete including centrifuging of oil (if required) up to getting di-electric strength near 60 KV complete all as specififed and as directed. \nMake: Servo/ Gulf/ Power oil 50 Ltrs
142 139 S&F air breather complete with silica gel for outdoor type transformer upto 100/315KVA including taking out existing UNSV breather from transformer 2 Nos
143 140 S&F, in replacement, silica gel all as directed 1 KG
144 141 Taking down carefully exisitng defective HT bushing from out door transformer and supply and fixing new HT bushing for outdoor type transformer of capacity 100 to315 KVA complete all as specified and as directed. 1 Set of three
145 142 Taking down carefully exisitng defective LT bushing from out door transformer and supply and fixing new LT bushing for outdoor type transformer of capacity 100 to 315 KVA complete all as specified and as directed. 1 Set of four
146 143 Supply and fix and replacement of gasket of any size transformer of any capacity after taking down unserviceable gasket complete all as specified and as directed. 1 Set
147 144 Dismantling and taking down the existing defective street light fitting of any type and any capacity SV/MV /T-5/CFL 36W from steel tubular pole, opening the street light fitting, checking the serviceability of spare parts including replacement of defective parts such as lamp holder, ballast, lamp HPSV 48/70/150/250/400 Watt, T5 fitting and CFL36 watt (Make Philips/BAJAJ/Havells) ignitor, acrylic cover & replacement of PVC wire of size 2.5 Sqmm copper multi stand etc reassembling the same including copper ballast &connecting from OH line to the fitting, after repairing including refixing on pole including connecting & testing complete all as directed by Engr-in-Charge. \n[Note:- HPSV LAMP 70/150/250 Watts, ballast, ignitor, capacitor, electronic chokes and CFL 36 Watt anf T5 fitting will be measured and paid separately on respective item of Sch 'A' here-in-after]. 70 Each
148 145 S & F LED street light 35 W pressure die cast aluminium housing with IP 66 with all accessories complete. \nMake - Havells, Cat No - LHETBXU7PA or equivlant model of make as per list of manufacturer. \n 21 Each
149 146 M/L and replacement of T-5 lamp holder 24 watts Lamp base G13 \nCat part No LHYT 11000099 50 Each
150 147 M/L and replacement of T-5 lamps 24 watts T-5 HO-650019\nCat part No LHST 26124699 35 Each
151 148 M/L and replacement of electrtonic ballast for T-5 lamp24 watts 2X24 watt FTL \nCat part No LHBT 01224034 44 Each
152 149 M/L and replacement of Indoor/outdoor cable end terminal joints (Resin cast type kits ) any type complete suitable for LT PVC insulated, sheathed UG cable for aluminium conductor cable of size 35 to 95 Sqmm 3.5 core. 2 Each
153 150 -ditto - but size 95 to 150 sqmm 3.5 core. 2 Each
154 151 M/L and replacement of MCCB 200 Amps 4pole 415 Volts 36 KA, \nMake - L & T/Havells/Legrand 1 Each
155 152 M/L and replacement of MCCB 250 Amps 4pole 415 Volts 36 KA, \nMake - L & T/Havells/Legrand 1 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail