Renovation Work Of D . T . P . C Office At Mananchira Kozhikode Renovation Works, MANAMCHIRA KOZHIKODE-Kerala

District Nirmithikendra Kozhikkode has published Renovation Work Of D . T . P . C Office At Mananchira Kozhikode Renovation Works. Submission Date for this Tender is 11-01-2021. Building Repair Tenders in MANAMCHIRA KOZHIKODE Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

26482969
Renovation Work Of D . T . P . C Office At Mananchira Kozhikode Renovation Works
Open Tender
Indian
Kerala
MANAMCHIRA KOZHIKODE
11-01-2021

Tender Details

Renovation Work Of D . T . P . C Office At Mananchira Kozhikode Renovation Works

Key Value

Document Fees
Refer document
EMD
INR 50000.0 /-
Tender Value
INR 27.20 Lakhs /-

BOQ Items

Work Name : ESTIMATE FOR THE PROPOSED RENOVATION WORK OF D.T.P.C OFFICE AT MANANCHIRA KOZHIKODE
Sl. No. Item Description Item Code / Make Quantity Units
1 1 DEMOLISHING WORKS BI01010001010000000000000515BI0100001113
2 1.01 15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar BI01010001010000000000000515BI0100001114 3.5 cum
3 1.02 15.12.2 : Of area beyond 3 sq. metres BI01010001010000000000000515BI0100001115 1 each
4 1.03 15.23.2 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles above 25 mm and up to 40 mm BI01010001010000000000000515BI0100001116 546.66 sqm
5 1.04 15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved BI01010001010000000000000515BI0100001117 30.672 cum
6 1.05 15.28.2 : Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos Sheet BI01010001010000000000000515BI0100001118 48.7 sqm
7 2 CIVIL WORKS BI01010001010000000000000515BI0100001119
8 2.01 2.1.1 : Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil BI01010001010000000000000515BI0100001120 150 sqm
9 2.02 50.2.33.5 : Cutting branches of trees overhanging above any structures of girth between 40cm to 60cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete. BI01010001010000000000000515BI0100001121 12 each
10 2.03 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil BI01010001010000000000000515BI0100001122 2.88 cum
11 2.04 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) BI01010001010000000000000515BI0100001123 23.219 cum
12 2.05 5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size BI01010001010000000000000515BI0100001124 1.008 cum
13 2.06 5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) BI01010001010000000000000515BI0100001125 0.961 cum
14 2.07 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete BI01010001010000000000000515BI0100001126 1.92 sqm
15 2.08 5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts BI01010001010000000000000515BI0100001130 9.601 sqm
16 2.09 od141969/2020_2021 : Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) BI01010001010000000000000515BI0100001147 560 sqm
17 2.1 od142034/2020_2021 : Providing & fixing on Ceiling clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) BI01010001010000000000000515BI0100001116 93 sqm
18 2.11 10.16.3 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes BI01010001010000000000000515BI0100001117 378.601 kg
19 2.12 50.9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood BI01010001010000000000000515BI0100001118 0.588 cum
20 2.13 50.9.2.1 : Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge.using Anjili/ Jack wood BI01010001010000000000000515BI0100001119 30.781 sqm
21 2.14 9.92.1 : Providing and fixing chromium plated brass handles with necessary screws etc.\ncomplete:125 mm BI01010001010000000000000515BI0100001120 4 no
22 2.15 50.9.13.1 : Supplying and fixing Anjily wood wrought and put up for roof members including cost and conveyance of materials etc. complete . BI01010001010000000000000515BI0100001121 2.273 cum
23 2.16 50.9.17.2 : Providing and Fixing Anjili wood frame work consisting of battens 50x25 mm fixed with rawlplug & drilling necessary holes and including priming coat etc complete BI01010001010000000000000515BI0100001122 0.782 cum
24 2.17 14.6.1 : Renewing glass panes, with wooden fillets wherever necessary:Float glass panes of thickness 4 mm BI01010001010000000000000515BI0100001123 38.7 sqm
25 2.18 14.85 : Taking out existing wooden door shutter, repair by cutting, painting etc. andrefixing of repaired door shutters to existing door frames, including replacementof hinges with screws, etc. as required, all complete as per the direction of theEngineer-in-charge. BI01010001010000000000000515BI0100001124 69.3 sqm
26 2.19 50.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. BI01010001010000000000000515BI0100001125 5.474 cum
27 2.2 13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand) BI01010001010000000000000515BI0100001126 108.301 sqm
28 2.21 14.1.2 : Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:Cement mortar 1:4 ( 1 cement: 4 coarse sand) BI01010001010000000000000515BI0100001130 50.401 sqm
29 2.22 11.38 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete. BI01010001010000000000000515BI0100001161 27.053 sqm
30 2.23 11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. BI01010001010000000000000515BI0100001162 83.163 sqm
31 2.24 14.43 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. BI01010001010000000000000515BI0100001163 700 sqm
32 2.25 13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm BI01010001010000000000000515BI0100001164 2052.86 sqm
33 2.26 13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work BI01010001010000000000000515BI0100001165 60.75 sqm
34 2.27 14.52.1 : Painting with oil type wood preservative of approved brand and manufacture:Old work ( one or more coats) BI01010001010000000000000515BI0100001166 1508.89 sqm
35 2.28 od162600/2020_2021 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:<br>12.5 mm thick plywood board BI01010001010000000000000515BI0100001167 107 sqm
36 2.29 od169529/2020_2021 : Chequerred Terracotta 12 mm thick in floor, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).<br>Dark shade pigment using ordinary cement BI01010001010000000000000515BI0100001168 306.66 sqm
37 2.3 16.68 : Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. BI01010001010000000000000515BI0100001169 342 sqm
38 2.31 30.2.33 : Providing and fixing Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and even, watering with sprinkler BI01010001010000000000000515BI0100001170 28.25 sqm
39 3 ELECTRICAL WIRING AND INSTALLATION BI01010001010000000000000515BI0100001171
40 3.01 90.2.1.1 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point BI01010001010000000000000515BI0100001172 15 point
41 3.02 90.2.1.3 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point BI01010001010000000000000515BI0100001130 15 point
42 3.03 90.2.1.4 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point BI01010001010000000000000515BI0100001147 12 point
43 3.04 90.2.1.6 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points BI01010001010000000000000515BI0100001149 15 each
44 3.05 90.2.1.7 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point BI01010001010000000000000515BI0100001150 4 each
45 3.06 1.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. BI01010001010000000000000515BI0100001151 7 each
46 3.07 1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). BI01010001010000000000000515BI0100001152 10 each
47 3.08 1.7.2 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC\n insulated copper conductor, single core cable in surface/ recessed steel conduit as required2X2.5 sq.mm+1X2.5 sq.mm earth wire BI01010001010000000000000515BI0100001153 75 metre
48 3.09 1.7.3 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC\n insulated copper conductor, single core cable in surface/ recessed steel conduit as required2x4 sq.mm + 1x4 sq.mm earth wire BI01010001010000000000000515BI0100001154 50 metre
49 3.1 1.7.4 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC\n insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 6 sq. mm + 1 X 6 sq. mm earth wire BI01010001010000000000000515BI0100001155 30 metre
50 3.11 1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm BI01010001010000000000000515BI0100001156 120 metre
51 3.12 od172730/2020_2021 : Supplying and fixing following way, three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB /Isolator4 way, Double door BI01010001010000000000000515BI0100001157 1 each
52 3.13 2.3.1 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door BI01010001010000000000000515BI0100001158 2 each
53 3.14 2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door BI01010001010000000000000515BI0100001159 1 each
54 3.15 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole BI01010001010000000000000515BI0100001160 24 each
55 3.16 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps BI01010001010000000000000515BI0100001161 2 each
56 3.17 2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps BI01010001010000000000000515BI0100001162 1 each
57 3.18 2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual\ncurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps BI01010001010000000000000515BI0100001163 2 each
58 3.19 2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual\ncurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps BI01010001010000000000000515BI0100001164 1 each
59 3.2 od172762/2020_2021 : Earthing with G.I. earth pipe 2.5 metre long, 38 mm dia including accessories, and providing<br>masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. BI01010001010000000000000515BI0100001165 1 set
60 3.21 90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) BI01010001010000000000000515BI0100001166 10 metre
61 3.22 90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) BI01010001010000000000000515BI0100001167 10 each
62 3.23 90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp BI01010001010000000000000515BI0100001168 80 metre
63 3.24 9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 10 sq. mm (25mm) BI01010001010000000000000515BI0100001169 14 set
64 3.25 od172794/2020_2021 : Supply and fixing of FRP Rectangular SINTEX SMC junction box BI01010001010000000000000515BI0100001170 6 each
65 3.26 od172795/2020_2021 : Bakelite Connector Strip BI01010001010000000000000515BI0100001171 6 each
66 3.27 90.3.19.1 : Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1x28wT5 fitting with APF electronic ballast suitable for continuous operation with THD less than 10%, power factor greater than 0.98, RoHS compliant, high lumen tube . BI01010001010000000000000515BI0100001172 16 each
67 3.28 90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C BI01010001010000000000000515BI0100001180 12 each
68 3.29 1.58 : Supplying and fixing PVC batten/ angle holder including connection etc. as required. BI01010001010000000000000515BI0100001180 12 each
69 3.3 od172895/2020_2021 : Supply and fixing of 9/12w LED lapm in existing batten holder (B22) BI01010001010000000000000515BI0100001181 12 each
70 3.31 90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) BI01010001010000000000000515BI0100001182 6 each
71 3.32 od172948/2020_2021 : Supply,conveyance,installation of Traditional Surface Mounted Wall Light Lamp BI01010001010000000000000515BI0100001183 16 each
72 3.33 od172949/2020_2021 : Supply, conveyance,installation of LED Hanging Pendant Light BI01010001010000000000000515BI0100001184 4 each
73 4 NETWORK WIRING BI01010001010000000000000515BI0100001185
74 4.01 1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable BI01010001010000000000000515BI0100001186 150 metre
75 4.02 od172981/2020_2021 : Supplying and drawn of 2 pair Telephone cable in the existing surface/recessed steel/PVC conduit as required. BI01010001010000000000000515BI0100001187 120 metre
76 4.03 od173006/2020_2021 : Installation, fixing and termination of RJ 11 data socket BI01010001010000000000000515BI0100001188 6 each
77 4.04 od173007/2020_2021 : Supply and fixing,crimping modular CAT6 RJ45 Data plug on existing CAT6 cable BI01010001010000000000000515BI0100001189 8 each
78 4.05 od173008/2020_2021 : Supply and fixing RJ 45 Data socket in suitable metallic box and giving necessary connection required BI01010001010000000000000515BI0100001190 8 each
79 5 DISMANTLING OF OLD ELECTRICAL WIRINGS BI01010001010000000000000515BI0100001191
80 5.01 od173021/2020_2021 : Wireman Helper BI01010001010000000000000515BI0100001192 2 Day
81 5.02 od173022/2020_2021 : Electrician BI01010001010000000000000515BI0100001193 2 Day
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail