}

Repair And Maintenance To Summer Appliances And Cooling Appliances And Other Misc Works And Ro Water Purifiers Installed At Various Units Of Delhi Cantt Under Ge ( U ) Plant And Machinery Delhi Cantt-10 . , DELHI CANTT-Delhi

Military Engineer Services-MES has published Repair And Maintenance To Summer Appliances And Cooling Appliances And Other Misc Works And Ro Water Purifiers Installed At Various Units Of Delhi Cantt Under Ge ( U ) Plant And Machinery Delhi Cantt-10 . . Submission Date for this Tender is 30-01-2021. Air Conditioner Tenders in DELHI CANTT Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

26478610
Corrigendum : Repair And Maintenance To Summer Appliances And Cooling Appliances And Other Misc Works And Ro Water Purifiers Installed At Various Units Of Delhi Cantt Under Ge ( U ) Plant And Machinery Delhi Cantt-10 .
Open Tender
Indian
Delhi
DELHI CANTT
30-01-2021

Tender Details

Repair And Maintenance To Summer Appliances And Cooling Appliances And Other Misc Works And Ro Water Purifiers Installed At Various Units Of Delhi Cantt Under Ge ( U ) Plant And Machinery Delhi Cantt-10 .

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Jan-2021 Corrigendum No 1 Technical Bid 23-01-2021
2 11-Jan-2021 Corrigendum No 1 Technical Bid 23-01-2021
3 23-Jan-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-01-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 95820.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR AND MAINTENANCE TO SUMMER APPLIANCES AND COOLING APPLIANCES AND OTHER MISC WORKS AND RO WATER PURIFIERS INSTALLED AT VARIOUS UNITS OF DELHI CANTT UNDER GE(U) P&M, DELHI CANTT -10.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down for servicing of split type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge. 280 Each job
2 2 Taking down for servicing of Window type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge.\nNotes for Ser Item No 1 & 2 :- \n(i) Replacement of defective spares for making the AC units in satisfactory working condition will be measured & paid separately under relevant items and Labour charges for taking out old spares & refixing of new spares shall deemed to be included in unit quoted rate. \n(ii) Penalty will be charged for not attending complaint from 12 Hours to 24 hours Rs. 500/- each complaint. Further if complaint not attended and rectified within 24 hours after intimation (Intimation will be given by message/whats app/mail by mentioning time of complaint, for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency and double of the job order amount to be deducted from contractors dues. 70 Each job
3 3 Supply only Running capacitor 36+6 MFD. (Make:- Epcos/ Usha/ Keltron.) 70 Each
4 4 Supply only Running capacitor 45+5 MFD. (Make:- Epcos/ Usha/ Keltron.) 70 Each
5 5 Supply only Running capacitor 50+6 MFD. (Make:- Epcos/ Usha/ Keltron.) 70 Each
6 6 Supply only Starting capacitor 80-100 MFD. (Make:- Epcos/ Usha/ Keltron.) 25 Each
7 7 Supply only Starting capacitor 100-120 MFD. (Make:- Epcos/ Usha/ Keltron.) 25 Each
8 8 Supply only Starting Relay 1622. (Make:- Hytech/ Renutrol/ Sri Ram/Microtech.) 30 Each
9 9 Supply only Starting Relay 2000. (Make:- Hytech/ Renutrol/ Sri Ram/Microtech.) 32 Each
10 10 Supply only Overload Relay. (Make:- Hytech/ Renutrol/ Sri Ram/Microtech.) 28 Each
11 11 Supply only Thermostat switch 2059/2064/2054. ( Make :- Indfos/ Renutrol). 20 Each
12 12 Supply only Condenser fan blade for Window type A.C of Capacity 1.5/2 TR made of Plastic. 9 Each
13 13 Supply only Condenser fan blade for spilt Type A.C of Capacity 1.5/2 TR made of Plastic. 9 Each
14 14 Supply only Wiring kit for Window/split type AC of Capacity 1.5/2 TR 9 Each
15 15 Supply only remote control compatible for split AC Cap 1.5/2 TR of make as per site requirement as directed by Engr-in-Charge. (Make-As per sample) 18 Each
16 16 Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for split/Tower AC of capacity 1.5/2/4 TR as directed by Engr-in-Charge. 20 Each
17 17 Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for window AC of capacity 1.5/2 TR as directed by Engr-in-Charge.\nNote for item No 3 to 17:- \nMaterials of item No 3 to 17 to be incorporated in item No 1 & 2 here-in-before. \n 15 Each
18 18 Supply & fixing in repairs plastic louvers (Front panel) for Window AC 1.5/2 TR complete all as directed by Engr-in-Charge. 4 Each
19 19 Supply & fixing in repairs of suction and discharge valve set of size 15mm (5/8''), 6mm (1/4'') and 12mm (1/2'') for Split AC 1.5/2 TR capacity complete all as directed by Engr-in-Charge. {Note:- (i) 15mm (5/8'') or 6mm (1/4'') and 12mm (1/2'') made one set\n(ii) Supply & filling of refrigerant gas shall be measured and paid under relevent item.} 38 Each
20 20 Supply & fixing in repairs of capillary tube for Split/ Window type AC of capacity 1.5/2 TR complete all as directed by Engr-in-Charge. 60 Each
21 21 Supply & fixing in repairs of capillary filter for Split/ Window type AC of capacity 1.5/2 TR complete all as directed by Engr-in-Charge. 60 Each
22 22 Disconnecting the unserviceable PCB compatible from existing Window/ Split type AC of capacity 1.5/ 2/ 4TR and refixing after necessary repair for satisfactory functioning of the AC unit complete all as specified and directed by Engineer-in-charge. 60 Each
23 23 Taking down unserviceable reversible valve for split/ window type AC of capacity 1.5TR and supply & fixing new reversible valve with solenoid coil including required copper pipe complete all as specified and directed by Engr-in-charge. (Make:- As per sample) (Note:- Supply & filling of refrigerant gas shall be measured and paid under relevent item.) 20 Each Job
24 24 -ditto- all as per item No. 23 above but spilt/window type Air Conditioner of capacity 2 TR. 18 Each Job
25 25 Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the window type Air Conditioner of Cap 2 Ton, of any make any type from any location and Supply , Installing and testing of new sealed unit compressor alongwith test certificate from manufacturer including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification capillary tube etc & Charging of Gas R-22/R-134a/R-32 and commissioning complete all as specified & directed by Engg-in-Charge. (Make:- Emerson /Tecumseh/ LG)\nNote :- Transportation Charges from site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above. 4 Each job
26 26 -ditto- all as per item No. 25 above but window type Air Conditioner of Capacity1.5 TR. (Make:- Emerson /Tecumseh/ LG) 20 Each job
27 27 -ditto- all as per item No. 25 above but spilt type Air Conditioner of Capacity 2 TR. (Make:- Emerson /Tecumseh/ LG) 20 Each job
28 28 -ditto- all as per item No. 25 above but spilt type Air Conditioner of Capacity 1.5 TR. (Make:- Emerson /Tecumseh/ LG) 20 Each job
29 29 Supply & fixing in repairs of Window A/C air blower motor copper wounded for 1.5 TR & 2 TR capacity AC complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.) 24 Each job
30 30 Supply & fixing in repairs copper wounded Indoor Air blower motor for Split 1.5 TR & 2 TR capacity complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.) 32 Each job
31 31 Supply & fixing in repairs of copper wounded condenser fan motor for Split type AC of 1.5 TR & 2 TR capacity outdoor units complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.) 42 Each job
32 32 Disconnecting the mains and taking out the unserviceable condenser coil of window type AC of capacity 1.5/ 2TR of any make from any location and supply, fixing and testing new condenser coil as per existing size & patterns for complete all as specified & as directed. (Make:- Voltas/Carrier/LG) 10 Each job
33 33 -ditto- all as per item No. 32 above but spilt type Air Conditioner Capacity 1.5/ 2 TR. (Make:- Voltas/Carrier/LG) 18 Each job
34 34 Supply & fixing in repairs of evaporator/cooling coil for window type Air Conditioner of capacity 1.5/ 2TR of existing make and size complete all as specified & as directed by Engr-in-Charge. 15 Each job
35 35 -ditto- all as per item No. 34 above but spilt type Air Conditioner Capacity 1.5/ 2 TR. 10 Each job
36 36 Supply and fixing in repairs of 1.5TR capacity split type Air Conditioner outdoor kit including condenser coil (copper), copper wounded blower motor, chasis, base plate with energy efficient inverter type rotory compressor (including initial charging of refrigerant gas), reverse valve, suction and discharge valve, contactor, capacitors and copper pipes & PVC wires of suitable size for internal connection etc ready to install and suitable for use in cold and hot mode including taking down old one complete all as specified & as directed by Engr-in-Charge. (Make:- LG/ Voltas/ Carrier/ Hitachi.) 20 Each job
37 37 -ditto- all as per item No. 36 above but spilt type Air Conditioner of capacity 2 TR. (Make:- LG/ Voltas/ Carrier/ Hitachi.) 10 Each job
38 38 Supply and fixing in repairs new indoor unit for split type inverter AC of capacity 1.5 TR with remote ready to install & suitable for use in cold and hot mode including taking down old one complete all as directed by Engr-in-Charge. (Make:- LG/Voltas/Carrier/Hitachi.) 20 Each job
39 39 -ditto- all as per item No. 38 above but spilt type Air Conditioner of capacity 2 TR. (Make:- LG/Voltas/Carrier/Hitachi.) \nNote for item No. 36 to 39:- The outdoor and indoor units shall be of same makes. 10 Each job
40 40 Supply & fixing heavy duty copper pipe 12mm (1/2") dia/ bore complete including insulation brazing, welding, nuts, bolts and screws of required size including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- Malaysia/ camipro or equivalent). 70 RM
41 41 -ditto- all as per item No. 40 above but copper pipe 6mm (1/4") dia/ bore. 70 RM
42 42 -ditto- all as per item No. 40 above but copper pipe 15mm (5/8") dia/ bore. 50 RM
43 43 -ditto- all as per item No. 40 above but copper pipe 10mm (3/8") dia/ bore. 50 RM
44 44 Taking down unserviceable insulation for copper pipe, supply and fixing new insulation for copper pipes suitabale for Split AC of capacity from 1.5 to 4.0 TR all as specified and directed by Engineer-in-charge. 80 RM
45 45 Taking down unserviceable PVC drain pipe and supply & fixing new PVC drain pipe 15 mm dia for Split/window AC all as specified and directed by Engineer-in-charge. 30 RM
46 46 Supply and filling refrigerant gas R-22/R-410A in window type /Split Type AC unit of capacity 1.5/2/3/4 TR including detecting the leakage of gas at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition. (Make : Mefron/ Floron/ Refron.) 270 Kg
47 47 Taking down unserviceable contactor and supply and fixing new contactor single phase suitable for Split AC 1.5 to 4.0 TR all as specified as directed by Engineer in-charge. 5 Each
48 48 Dismantling and removing defective burnt blower unit motor of any capacity and make of 1.5/2 TR capacity window type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing all as directed. 5 Each Job
49 49 Dismantling and removing defective burnt blower unit motor of any capacity and make of indoor units of split/tower type AC of capacity 1.5/2/4 TR capacity rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing all as directed. 20 Each Job
50 50 Dismantling and removing defective burnt outdoor unit motor of any capacity and make of indoor units of split/tower type AC of capacity 1.5/2/4 TR capacity rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing all as directed. 30 Each Job
51 51 Dismantling the existing broken blower fan blade of the indoor units of the split type AC of Capacity 1.5/2 TR and supply and fixing in repairs new blower fan blade complete all as specified and directed. 15 Each Job
52 52 Supply and fixing in repairs of 1.5 TR capacity window type AC kit including condenser & evaporator coil (copper), copper wounded blower motor, chasis base plate, compressor (including initial charging of refrigerant gas), reverse valve, capacitor and copper pipes & PVC wires of suitable size for internal connection etc ready to install & suitable for use in cold and hot mode with remote including taking down old one complete all as specified & as directed by Engr-in-Charge. (Make:- Voltas/ Carrier/ Bluestar) 10 Each
53 53 Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded, unsheathed 1100 volts grade in PVC casing capping (heavy grade) of suitable size with all fittings and casing caping accessories of surface type including one run 6 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694) as earth wire including taking down old unserviceable sub main wiring complete all as specified and as directed. 400 RM
54 54 Material and labour for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded, unsheathed 1100 volts grade in PVC casing capping (heavy grade) of suitable size with all fittings and casing capping accessories of surface type including one run 4 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694) as earth wire including taking down old unserviceable sub main wiring complete all as specified and as directed. (Make of cable:- RR Kabel/Finolex/ Havells/ Polycab/ KEI Industries and make of Casing Caping:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST.) {Notes for item No.53 & 54 :-(i) Two runs of cable with one runs earth wire and PVC casing capping shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the casing capping. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 400 RM
55 55 Supply and fixing in repairs of metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 32 Amps including taking down old unserviceable metal clad socket complete all as specified and as directed. (Make:- Schnieder/ Legrand/ ABB/ Seimens/ L & T) 15 Each
56 56 Supply and fixing in repairs of MCB SP 240 volts 6 to 32 Amps, 10 kA, 'C' curve complete all as specified and as directed. (Make:- Schnieder/ Legrand/ ABB/ Seimens/L & T) 20 Each
57 57 Supply & fixing in repair metal clad socket of 20 Amps complete all as specified & as directed. (Make:- L & T/ Legrand/ Schneider/ ABB/Seimens) 10 Each
58 58 Supply & fixing in repairs metal clad plug with two pin of capacity 20 Amps complete all as specified & as directed. (Make:- L & T/ Legrand/ Schneider/ ABB/Seimens) 10 Each
59 59 Collecting of unserviceable voltage stabilizer of capacity 4 & 5 KVA from the MES store yard of AGE AC(OTBH) or dismantling the same from site and transporting to contractors workshop for locating the fault including checking the serviceability of electrical/electronic circuits relays and replacement of defective spare parts , reassembling after making connections, testing by applying low and high voltage input to get the 230 volts correct output and transporting back the same to MES store yard complete all as specified and directed by Engr-in-charge\nNote :- 1. Replacement of defective spares and rewinding of transformer of voltage stabilizer will be measured & paid separately under relevant items and Labour charges for taking out old spares & fixing of new spares shall deemed to be included in unit rate quoted. 30 Each Job
60 60 Supply only Voltmeter (Analog) 0 to 300 volts any type shape single phase 50 Hz AC supply. \n(Make:- AE/ MIECO/ Rishabh) 5 Each
61 61 Supply only Digital type Voltmeter 0 to 300 volts any type shape single phase 50 Hz AC supply, (Make:- AE/ MECO/ Rishabh) 5 Each
62 62 Supply only Printer circuit control card suitable for 4 to 5 KVA. 15 Each
63 63 Supply only Input/output switch (Make:- AE/Rishabh/Meco) 15 Each
64 64 Supply only Push on switch (Make:- AE/Rishabh/Meco) 15 Each
65 65 Supply only Indicator with neon bulbs (Make:- AE/L & T/ C & S/ Renutrol/ Technomac) 15 Each
66 66 Supply only Trigger Transformer for 4 & 5 KVA. 15 Each
67 67 Supply only Relay for 3 to 5 KVA voltage stabilizer. Make:- Renutrol/ Technomac 15 Each
68 68 Supply only Time delay and High/low voltage cut off circuit with relay suitable for 4 KVA & 5 KVA (Make Renutorl/Technomac) \n(Note for item No 60 to 68 :- Materials of item No 60 to 68 to be incorporated in item No 59 here-in-before ) 15 Each
69 69 Taking out the burnt winding of transformer of voltage stabilizer and preparing core after cleaning by suitable cleaning agent and rewinding the transformer of voltage stabilizer with super enameld copper wire of existing gauge including varnishing, heating and refiting of capacity 3 KVA voltage stabilizer, complete all as specifies & directed by Engr-in-Charge. 15 Each
70 70 -ditto- all as per item No. 69 here-in-before but 4 KVA. 15 Each
71 71 -ditto- all as per item No. 69 here-in-before but 5 KVA. 15 Each
72 72 Disconnecting from mains and taking down for servicing of Water Cooler of Capacity 40/80, 60/120, Ltrs including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc., and keeping the Water cooler unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed by Engineer-in-Charge.\nNote :- 1. Replacement of defective spares for making the water cooler units in satisfactory working condition will be measured & paid separately under relevant items and Transportation & labour charges for taking down old spares and fixing of new spares shall deemed to be included in unit rate quoted above. 100 Each
73 73 Supply only over load protector relay suitable for 40/80 Ltrs capacity water coolers. (Make : Renutrol/Sri Ram/Microtech) 15 Each
74 74 Supply only thermostat suitable for 40/80/120/150 Ltr capacity water coolers. (Make : Indfas/Renutrol) 30 Each
75 75 Supply only condenser motor fan blade suitable for 40/80/120/150 Ltr capacity water coolers. 10 Each
76 76 PVC flexible drain Hose Pipe 40 mm. 15 RM
77 77 Waste water tray complete suitable for 40/80, 60/120, 150/150 Ltr capacity water coolers all as directed. ( Suitable for Voltas/Sidwal/Blue Star make water coolers). 2 Each
78 78 Supply only chromium plated push taps suitable for 40/80/120/150 Ltr capacity water coolers all as directed.\nMake : Usha/Prayag/Cera/Essco. 30 Each
79 79 Supply only PVC float valve of size 15mm dia complete suitable for 40/80/120/150 Ltr capacity water coolers including GI socket of same size all as directed. 10 Each
80 80 Supply only Starting Capacitor 25 MFD. (Make :- Usha/Epcos/Keltron) 20 Each
81 81 Supply only running Capacitor 10 MFD.(Make :- Usha/Epcos/Keltron) 20 Each
82 82 Supply only Starting relay suitable for 40/80, 60/120, 150/150 Ltr. Make : Renutrol/Sri Ram/Microtech.\nNote for item No 73 to 82:- \nMaterials of item No 73 to 82 to be incorporated in item No 72 here-in-before. \n 15 Each
83 83 Disconnecting the electric mains and taking out unserviceable condenser fan motor 1/16 HP from water cooler cap.60/120, 150/150 Ltr and supply and replace with new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as directed by Engr-in-Charge. (Make : AUE, Crompton Greaves / Cool Master) 20 Each Job
84 84 All as per item No.83 above but 1/32 HP Water cooler of Capacity 40/80 Ltrs. 20 Each Job
85 85 Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-22/134A, commissioning and testing Water Coolers of 40/80 Ltrs capacity complete all as specified and directed. (Make :- Emerson /Tecumseh/LG.) 20 Each
86 86 Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-22/134A, commissioning and testing Water Coolers of 60/120 Ltrs capacity complete all as specified and directed. (Make :- Emerson /Tecumseh/LG.) 20 Each
87 87 Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-22/134A, commissioning and testing Water Coolers of 150/150 Ltrs capacity complete all as specified and directed. (Make :- Emerson /Tecumseh/LG.) 10 Each
88 88 Disconnecting the mains and taking out the unserviceable condenser coil and S&F new condenser coil as per existing size & patterns for Water Coolers of capacity 60/120, 150/150 Ltrs complete all as specified & as directed. 10 Each job
89 89 Disconnecting the mains and taking out the unserviceable condenser coil and S&F new condenser coil as per existing size & patterns for Water/Coolers of capacity 40/80 Ltrs complete all as specified & as directed. 12 Each job
90 90 Dismantling the evaporator/cooling coil of water cooler capacity 150/150, 60/120 & 40/80 Ltrs, checking the leakages of gas and rectify the leakages by brazing or any other manner complete all as specified & as directed by Engr-in-Charge. 8 Each Job
91 91 Taking down unserviceable PVC connection pipe and Supply and Fixing of PVC connections 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed. (Make:- Prayag/ Polytuff) 10 Each Job
92 92 Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-22/134A, commissioning and testing refrigerators of 165 to 210 Ltrs capacity complete all as specified and directed. \nMake :- Emerson /Tecumseh/LG. 15 Each
93 93 Dismanling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-22/134A, commissioning and testing refrigerators of 280 to 310 Ltrs capacity complete all as specified and directed. (Make :- Emerson /Tecumseh/LG.)\nNote :- (i) The rates quoted by the contractor shall deemed to include the transportation cost from site of installation to contractor's repair workshop and back. 12 Each
94 94 Dismantling of existing repairable Refrigerators of any make and from its position after disconnecting electric connections, transporting from site to contractor's workshop for carrying out repairs and renewal/replacement of parts, reassembling and transporting back to the site including installation of the same on the same location and making electric connection etc, all as specified and directed by Engineer-in-Charge. (Note :- Parts renewed shall be measured and paid separately under appropriate items.) 8 Each Job
95 95 Supply and filling refrigerant gas R-134A in Refrigerator/ Deep freezers/ water coolers of any capacity, model and make including detecting the leakage of gas at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition. Make:- mefron/ Floron/ Refron 200 Kg
96 96 Supply and filling refrigerant gas R-32 in Window/ Split type ACs of any capacity, model and make including detecting the leakage of gas at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition. Make:- mefron/ Floron/ Refron 50 Kg
97 97 Supply and fixing in repairs capillary tube of existing size including necessary brazing suitable for 165/ 300 Ltrs capacity refrigerator, including dismantling the old unserviceable one all as specified and directed. 30 Each Job
98 98 Supply and fixing in repairs over load protector relay suitable for 165/300/310 Ltrs capacity refrigerator all as directed. (Make : Renutrol/Sri Ram/Microtech) 8 Each
99 99 Supply and fixing in repairs thermostat suitable for 165/300/310 Ltrs capacity refrigerators all as directed. (Make: Indfoss/Renutrol/Godrej.) 9 Each
100 100 Supply and fixing in repairs freezer door with spring of refregierators of any capacity complete all as specified and directed by Engr-in-charge. 10 Each
101 101 Supply and fixing in repairs vegetable basket with glass suitable for 165/300/310 Ltrs capacity refrigerators complete all as specified and directed by Engr-in-charge. 10 Each
102 102 Supply and fixing in repairs PVC defrost tray as per sample suitable of 165/300/310 Ltrs capacity refrigerators. (Make : Suitable for Whirlpool/ LG/Samsung/ Godrej make refrigerator). 5 Each
103 103 Supply and fixing in repairs door gasket for refrigerators of capacity upto 250 Ltrs complete all as specified and directed. 5 Each
104 104 Supply and fixing in repairs door gasket for refrigerators of capacity more than 250 Ltrs but upto 310 Ltrs complete all as specified and directed. 3 Each
105 105 Dismantling of existing repairable deep freezers Capacity upto 500 Ltrs of any make and from its position after disconnecting electric connections, transporting from site to contractor's workshop for carrying out repairs and renewal/replacement of parts, reassembling and transporting back to the site including installation of the same on the same location and making electric connection etc, all as specified and directed by Engineer-in-Charge. {Note :- (i) Parts renewed shall be measured and paid separately under appropriate items. (ii) Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted. 20 Each Job
106 106 Supply only starting relay 1/6 HP open with OLP all as specified and directed. \nMake :- Renutrol/Sri Ram/Microtech 10 Each
107 107 Supply only starting relay for 1/8 HP open type with OLP all as specified and directed. \n(Make : Renutrol/Sri Ram/Microtech) 10 Each
108 108 Supply only over load protector suitable for upto 500 Ltrs capacity deep freezer all as specified and directed. (Make : Renutrol/Sri Ram/Microtech) 10 Each
109 109 Supply only running capacitor for upto 500 Ltrs capacity deep freezer all as specified. (Make : Epcos/Usha/ Keltron) 10 Each
110 110 Supply only thermostat suitable for upto 500 Ltrs capacity deep freezer all as specified and directed. ( Make :- Indfos/ Renutrol). 10 Each
111 111 Supply only starting capacitor for upto 500 Ltrs capacity deep freezer all as specified and directed. (Make : Epcos/Usha/ Keltron)\n\n 10 Each
112 112 Supply only Axial Fan for deep freezers complete all as specified and directed. \nNote for item No 106 to 112:- \nMaterials of item No 106 to 112 to be incorporated in item No 105 here-in-before. 10 Each
113 113 Taking down defective compressor of deep freezer of capacity Upto 300 Ltrs and any make and supplying and fixing new sealed unit compressor as specified here under including brazing and with necessary nuts and bolts, copper filter, capilary and supply & charging of refrigerant gas Non CFC based or equivalent to Non CFC gas in required qty and testing complete all as specified and directed by Engineer-in-Charge. (Make :- Emerson /Tecumseh/LG.) 10 Each
114 114 All as per item No 113 above but of capacity above 300 Ltrs but upto 500 Litres deep freezer compressors. (Make :- Emerson /Tecumseh/LG.) 10 Each
115 115 M&L for taking down desert cooler of any type/size/model from any height / floor for servicing like changing of wood wool pads, kit motor, submersible pump, fan blade, front grill, wiring, capacitor, cleaning or any other repair work as specified and re-fixing to existing place after repair work/overhauling complete all as specified and directed.\nNote :- (i) The rates quoted by the contractor shall deemed to include the cost of T&P.\n(ii) The items required to be replaced shall be measured and paid separately under relevant items as 'Supply only'. (iii) Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted.\n 500 Each Job
116 116 Supply only wood wool pad of suitable size for 24” sweep desert cooler complete all as specified and directed 01 Set comprising of 3 Nos of pads approximate weight 800-900 Gms As per sample.\n 300 Set of three
117 117 All as per item No 116 above but 20” sweep approximate weight 700 -800 Gms. As per sample. 300 Set of three
118 118 Supply only front grill for desert cooler of approved make suitable for fixing 5 Amp switch, three speed regulator and indicating lamp all as specified and directed. 10 Each
119 119 Supply only running capacitor of 4 MFD capacity for water cooler complete all as directed. \n(Make- USHA/EPCOS/KELTRON) 200 Each
120 120 Supply only running capacitor of 6 MFD capacity for water cooler complete all as directed. \n(Make- USHA/EPCOS/KELTRON) 100 Each
121 121 Supply only wire mesh for desert cooler pad (Set of Three) including taking down old one. 300 Each Set
122 122 Supply only PVC pipe for connecting pump and water distributor of size 15 mm dia. (Make:- Prayag/ Supreme/ Prince). 250 RM
123 123 Supply only PVC elbow for desert cooler of suitable size complete all as specified & as directed.\n\n 250 Each
124 124 Supply only PVC 4 Way distribution cross for desert cooler complete all as specified & as directed.\nNote for item No 116 to 124:- \nMaterials of item No 116 to 124 to be incorporated in item No 115 here-in-before. 250 Each
125 125 Supply and fixing in repairs of submersible pump motor 230 Volts, single phase, AC suitable for Plastic body/Steel body Desert cooler complete all as specified & as directed. (Make- Bajaj/ Crompton Greaves/ Khaitan.) 300 Each
126 126 Supply and fixing in repairs repairs of desert cooler kit fan motor, single speed, 230 V, 50 Hz of capacity 90 Watt 1450 RPM, copper wounded including nuts bolts for fixing complete all as specified and directed. (Make : Crompton Greaves/Usha/Khaitan) 250 Each
127 127 Supply and fixing in repairs of Desert cooler exhaust fan motor, single speed, 230 V, 50 Hz of capacity 150 Watt 1400 RPM, copper wounded including nuts bolts for fixing complete all as specified and directed. (Make : Havells/Crompton Greaves/Almonard) 50 Each
128 128 Supply and fixing of flexible copper conductor cable, 3 core PVC insulated & PVC sheathed of size 1.5sqmm including taking down old unserviceable one complete all as specified and directed. ( Make -Polycab/Kalinga Premium/Plaza). 300 RM
129 129 Supply and fixing in repairs of desert coolers fan blade of 18" (inch) sweep made out of Aluminium complete all as specified. 100 Each
130 130 Supply and fixing in repairs of desert coolers fan blade of 20" (inch) sweep made out of Aluminium complete all as specified. 100 Each
131 131 Supply and fixing in repairs of side panel of desert cooler of 20" (inch) sweep made out of 20 SWG, GI sheet suitable for fixing with the existing desert coolers, duly painted with synthetic enameled paint over a coat of red oxide primer complete all as specified and directed. 20 Each Set
132 132 Supply and fixing in repairs of switch piano flush type single pole one way 5Amp 230 V for desert cooler all as directed. (Make-Anchor/Kinjal/Havells) 200 Each
133 133 Supply and fixing in repairs of 3 pin plug top 15 Amp for desert cooler complete all as specified and directed. (Make-Anchor/Kinjal/Havells) 30 Each
134 134 All as per item No. 133 above but 5 Amps. (Make-Anchor/Kinjal/Havells)\n 150 Each
135 135 Supply and fixing in repairs cooler fan motor bracket sets made up as existing including painting complete all as specified and directed. 200 Each Set of four
136 136 Preparation for old painted surface of desert cooler of any capacity and any make on inner surface & outer surface. Repainting the complete desert coolers ie side panel, bracket, body & desert cooler stand with two coats of synthetic enameled paint (1st grade quality) including two coats of black water proof paint on reserve water tank & marking with “ GE(U) P&M (MES)” letter size of 50mm height at stencil in black/white including servicing and greasing of fan motor/pump and replacement of PVC pipe worn out nut, bolts and washers complete all as per site requirement. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.) 500 Each Job
137 137 S&F in repairs desert cooler body of size 25 inch x 25 inch x 36 inch (height) with side panels (03 Nos) fabricated out of 20 SWG PGI Sheet alongwith PVC front grill, distribution switch, 5 Amp piano switch and tank of depth 11 inch. Painting the complete desert cooler i.e, side panel, bracket body with two coat of synthetic enamel paint (Ist grade quality) over a coat of red oxide zinc chrome primer and two coat of black water proof paint on reserve tank and marking with "GE (U) P&M (MES)" letter size of 50mm height in stencil in black/ white all as specified and directed by Engr-in-Charge. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.) 250 Each
138 138 S&F in repairs new PCB suitable for LG (Dual Inverter)/ Hitachi/ Voltas/ Panasonic make inverter ACs of capacity 1.5/2 TR complete all as specified and directed by Engr-in-Charge. 12 Each
139 139 M&L for disconnecting the unserviceable PCBs from existing LG (Dual inverter)/ Hitachi/ Voltas/ Panasonic make inverter ACs of capacity 1.5/2 TR, and refixing after necessary repair to satisfactory functioning of the AC unit complete all as specified and directed by Engr-in-Charge. 12 Each
140 140 M&L for disconnecting the unserviceable DC condenser fan motor of outdoor units and supply, fixing and testing for proper functioning of existing LG (Dual inverter)/ Hitachi/ Voltas/ Panasonic make inverter ACs of capacity 1.5/2 TR. 6 Each
141 141 M&L for disconnecting the unserviceable DC blower fan motor of indoor units and supply, fixing and testing for proper functioning of existing LG (Dual inverter)/ Hitachi/ Voltas/ Panasonic make inverter ACs of capacity 1.5/2 TR. 6 Each
142 142 Supply and fixing in repairs new indoor unit for split type AC of capacity 3.0 TR with remote ready to install including taking down old one complete all as directed by Engr-in-Charge. (Make:- Carrier/ Voltas/ Bluestar) 1 Each Job
143 143 Disconnecting from mains and Taking down for servicing of Auqa guards and RO water purifier of Capacity 8 to 20 LPH including detecting the leakage of water and refilling, cleaning of unserviceable items including checking the servicibility of electrical/electronic circuits relays, wiring kit, etc., and keeping the RO system in satisfactory working condition all as specified and as directed by Engineer-in-Charge.\n{Note :- (i). Replacement of defective spares will be measured & paid separately under relevant items as 'Supply only'. (ii) Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted.} 10 Each Job
144 144 Supply only Carbon Filter for 8 to 20 LPH RO water purifier. \nMake - Kent/ PRW/ Aquasure/ Aquapure/ Aquafresh/ Amritanjal 6 Each
145 145 Supply only Sediment Filter for 8 to 20 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 6 Each
146 146 Supply only Post Carbon Filter for 8 to 20 LPH RO water purifier. \nMake - Kent/ PRW/ Aquasure/ Aquapure/ Aquafresh/ Amritanjal 6 Each
147 147 Supply only Membrane Filter 75GPD. Make - Kent/ PRW/ Aquasure/ Aquapure/ Aquafresh/ Amritanjal 6 Each
148 148 Supply only Spun Filter for 8 to 20 LPH RO water purifier. Make - Kent/ PR/ Aquasure/ Aqua pure 6 Each
149 149 Supply only Pump for RO water purifier 100PSI/600RP 75GPD. \nMake - Kent/ PRW/ Aquasure/ Aquapure /Aquafresh/ Amritanjal 6 Each
150 150 Supply only Solenoid Valve 24V DC for 8 to 20 LPH RO water purifier. \nMake - Kent/ PRW/ Aquasure/ Aquapure/ Aquafresh/ Amritanjal 2 Each
151 151 Supply only Water Level Sensor with Float for 8 to 20 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 4 Each
152 152 Supply only UV Lamp 11W for 8 to 20 LPH RO water purifier. Make -Kent/PRW/Aquasure/Aqua pure 2 Each
153 153 Supply only UV Lamp Assembly 11W for 8 to 20 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 2 Each
154 154 Supply only UV Adapter for 8 to 20 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal\nNote for item No 144 to 154:- Materials of item no 144 to 154 to be incorporated in item No 143. 1 Each
155 155 Disconnecting from mains and Taking down for servicing of Auqa guards and RO water purifier of Capacity 25 to 30 LPH including detecting the leakage of water and refilling, cleaning of unserviceable items including checking the servicibility of electrical/electronic circuits relays, wiring kit, etc., and keeping the RO system in satisfactory working condition all as specified and as directed by Engineer-in-Charge.\nNote :- 1. Replacement of defective spares will be measured & paid separately under relevant items as 'Supply only'. 2. Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted. 10 Each Job
156 156 Supply only Membrane Filter 100 GPD. Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 15 Each
157 157 Supply only Pump for RO water purifier 100PSI/600RP 100GPD. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 10 Each
158 158 Supply only Calcium Treatment Unit (CTU) Filter for 25 to 30 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 15 Each
159 159 Supply only JCO Filter. Make - Kent/PR/Aquasure/Aqua pure 15 Each
160 160 Supply only Carbon Filter for 25 to 30 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 15 Each
161 161 Supply only Spun Filter for 25 to 30 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 15 Each
162 162 Supply only FRT 300 ML for 25 to 30 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 15 Each
163 163 Supply only Solenoid Valve 36V DC for 25 to 30 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 10 Each
164 164 Supply only Sediment Pre Filter for 40 to 50 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal\nNote for item No 156 to 164:- Materials of item no 156 to 164 to be incorporated in item No 155. 5 Each
165 165 Disconnecting from mains and Taking down for servicing of Auqa guards and RO water purifier of Capacity 40 to 50 LPH including detecting the leakage of water and refilling, cleaning of unserviceable items including checking the servicibility of electrical/electronic circuits relays, wiring kit, etc., and keeping the RO system in satisfactory working condition all as specified and as directed by Engineer-in-Charge.\nNote :- (1). Replacement of defective spares will be measured & paid separately under relevant items as 'Supply only. (2) Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted. 15 Each Job
166 166 Supply only Membrane Filter 150 GPD. Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 25 Each
167 167 Supply only Pump for RO water purifier 100PSI/600RP 150GPD. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 4 Each
168 168 Supply only Calcium Treatment Unit (CTU) Filter for 40 to 50 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 10 Each
169 169 Supply only Spun Filter for 40 to 50 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 10 Each
170 170 Supply only Inline Carbon Filter 8" for 40 to 50 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 10 Each
171 171 Supply only Post Carbon Filter. Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 10 Each
172 172 Supply only FRT 800 ML for 40 to 50 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 10 Each
173 173 Supply only Solenoid Valve 36V DC for 40 to 50 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 10 Each
174 174 Supply only Sediment Pre Filter for 40 to 50 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 5 Each
175 175 Supply only Water Level Sensor with Float for 40 to 50 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal\nNote for item No 166 to 175:- Materials of item no 166 to 175 to be incorporated in item no 165. 5 Each
176 176 Disconnecting from mains and Taking down for servicing of Auqa guards and RO water purifier of Capacity 80 to 100 LPH including detecting the leakage of water and refilling, cleaning of unserviceable items including checking the servicibility of electrical/electronic circuits relays, wiring kit, etc., and keeping the RO system in satisfactory working condition all as specified and as directed by Engineer-in-Charge.\nNote :- (1). Replacement of defective spares will be measured & paid separately under relevant items as 'Supply only'. (2) Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted. 15 Each Job
177 177 Supply only Membrane Filter 300 GPD. Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 58 Each
178 178 Supply only Pump for RO water purifier 100PSI/600RP 300GPD. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 4 Each
179 179 Supply only Calcium Treatment Unit (CTU) Filter for 80 to 100 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 15 Each
180 180 Supply only Spun Filter for 80 to 100 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 15 Each
181 181 Supply only Carbon Filter 8" for 80 to 100 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 15 Each
182 182 Supply only Solenoid Valve 48V DC for 80 to 100 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 4 Each
183 183 Supply only Water Level Sensor with Float for 80 to 100 LPH RO water purifier.\nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 3 Each
184 184 Supply only Membrane housing set for 80 to 100 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 5 Each
185 185 Supply only Sediment Pre Filter for 80 to 100 LPH RO water purifier. \nMake - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 10 Each
186 186 Supply only SMPS 2.5 Amp 24Volts DC. Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 3 Each
187 187 Supply only SMPS 3 Amp 36Volts DC. Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 4 Each
188 188 Supply only SMPS 4 Amp 48Volts DC. Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 2 Each
189 189 Supply only Adaper 2.5 Amps 24Volts DC. Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal 2 Each
190 190 Supply only Adaper 3 Amps 36Volts DC. Make - Kent/PRW/Aquasure/ Aquapure/Aquafresh/Amritanjal 2 Each
191 191 Supply only Adaper 4 Amps 48Volts DC. Make - Kent/PRW/Aquasure/Aquapure/Aquafresh/Amritanjal\nNote for item No 177 to 191:- Materials of item no 177 to 191 to be incorporated in item No 176. 2 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail