Tender Details

Supply Of Electronics Equipments 1. Laboratory Bacteriological Incubator Double Wall Chambers Inner Made Of Stainless Steel Outer Body Of Mild Steel Sheet Duly Powder Coated With 2 1/2 Thick Glass Wool Insulation. Temperature Is Controlled By An Imported Thermostat To A Maximum Of 80 C With An Accuracy Of +1 C Working Temperature Range 37 C To 80 C Three Chambers, Removable Shelves Should Have Effective Capacity Minimum 50 Liters. Air Ventilators To Be Provided On Both Sides The Equipment To Be Provide With Control Panel Having A Thermostat Control Knob, On-Off Switch Pilot Lamp And Timer, Digital Indicator Temperature Homogeneity Between Top And Bottom Shelves Should Be Maintained Sine 24 X24 X 24, 2. Orbital Shaking Incubator Brushless Induction Motor With Variable Frequency Drives Operations Step Less Variable Frequency Drive Ensures Gentle Shaking Start And Maintains Set Speed Counter Balanced Mechanism For High Stability In Uneven Load Of Different Sized Flasks Universal Shaking Platform To Accommodate Different Sized Assorted Flasks Maximum Shaking Capacity 5 Flasks X 1000 Ml Powerful Fan Motor For Forced Air Circulation To Maintain Uniform Conditions Inside Chamber, 3. Refrigerated Centrifuges Base Unit Table Top High Speed Refrigerated Centrifuge With Option Of Fixed Angle As Well As Swing Out Rotos. Should Give Max Speed Of 14,000 Rpm/Max Ref Of 20,000Xg Or Above With Fixed The Blower Unit Should Create A Suction Pressure Thro Ugh The Primary Filter (Or Ore Filter), Which Removes Dust Particles Of Above 10 Micron Size In The First Stage. Subsequently, The Filtered Air Passed To The Hepa Filters, Where The Particles Or Substances Of 0.3 Micron Size And Above Are Removed. Finally The Ultra Clean Filtered Air Supplied To The Working Chamber As A Uniform Airflow To Perform Precision Analysis Activates. Cabinet (Material Of Construction): The System Should Have Laminar Air Flow Cabinet Should Have Fully Enclosed Bench Designed. The Laminar Flow Bench Should Have Stainless Steel Ss 304 Table With Ms Coated Tabular Frame And Body. Laminated Unit Should Also Have Stand By Control System With Lock And Key. Unit: The Unit Should Have Door Should Be Made Of Tempered Safety Glass Sliding Door Or Glass Wind Screen Should Have Led Display To Show Measured Parameters Like Stage Velocity, Total Using Time, Uv/Fi Lamp On/Off Unit Should Have Differential Pressure Indicator. Cleanliness Level: The System Should Have Class 100 (Iso 5 For Particle Sizes 0.5 U <3530 Particles/M3 Of Air At Both At Rest& Operation Condition As Per Iso 14644 1 Working Size: 4 Ft X 2 Ft X 2 Ft Work Table: Oit Should Have Is 304 Grade Stainless Steel With Finish 4 Polish Surface Front Door 5 Mm Thick Clear Acrylic Sheet- Vertical Sliding Direction Of Flow: Horizontal Airflow Speed : Velocity Should Have 90 Feet/Minute=20/, 4. Refrigerator 250 Liters, Double Door, Inbuilt Stabilizer, Stand, 5. Uv Visible Spectometer Optical Design Iv File Holder For Measurement Of Direct Transmittance Of Films Warranty 03 Yers Of Warranty, 6. Conductivitity Meter Conductivity Meter With Conductivity. Cell For The Conductivity Meter, Cond/Tds Electrode., 7. Autoclave Design: Unit Made Of Ss 304 Chamber, Lid Made Of Heavy Gauge Lid, Die Pressed S.S.304 With Pressure Gauge Steam Release Valve & Necessary Safety Valves, With Foot Lifting Arrangement To Open Lid, Programmable, With All Functional Accessories The Sterilization Chamber Should Be Made Of Corrosion Resistant Stainless Steel Unit: Should Have Water Inlet And Outlet Valves. Should Have A Water Level Gauge Should Have Gauge For Measuring Inner And Outer Steam Pressure. Should Have An Inner Temperature Indicator. Should Have Automatic Pressure Control Switch Safety Valve And Eject Valve. Should Have Joint Less Silicone Gasket. Should Have Automatic Low Water Protection, 8. Haemometer Counting Chamber/Square Hb Tube,20 Ul H.B Pipette, Rebber Tube With Mouth Piece, Cleaning Brush, Glass Droper With Rubber Teat, Glass Rod, 9. Haemocytomer Conting Chamber With Rbc And Wbc Pipette, Complete Set, 10. Sonicator Power Rating : 700 Wats (150 Warts) Frequency : 20 Khz Programmability. 10 Memories Plus Sequencing Programmable Timer. 72 Hours Adjustable Pulse On/Off: I Second To 24 Hours Dimensions (Wxlxh): 8 X 15.25 X 8.5 In (203 X 387 X216 Mm) Voltage: 110V,50.160 Hz, 11. Muffle Furnance Max Temperature 9000C Working Temp 8000C, Heating Element Silicon Carbide (Sic), Temperature Controller Pid Controller, Display Led/Lcd Display, External Chamber Construction Ms W/Powder Coating/304 Grade Stainless Steel (Optional). Internal Chamber Construction Ceramic Board & Grooved Refractory Chamber As Per Temp. Requirement, Insulation Ceramic Wool Insulation, Alarm Audible & Visual Type, Power Supply 220/440 Volts, Certification Iso, Ce & Gmp, Stabilizer As Standard., 12. Homogenizer Rotor Speed Reange- Form 500 Upto 30,000 Rpm Quick Coupling For Dispersing Aggregates. Interchangeable Dispersing Aggregates In Ec Design Between Approx, 0.1Ml And 250 Ml Control Knob And Speed Scale. Voltage 220V + 10%, 13. Water Bath Material Of Construction: O It Should Be Double Walled Inside Stainless Steel And Outside Mild Steel Sheet Painted In Epoxy Powder Coating (Rust Resistant Material) With Lid Capacity Of 325X250x100mm. Unit: Bath Should Consist Of Two Pilot Lamp, Temperature Control Knob And On/Off Switch To Work On 220/230 Volts Ac Supplied With Or Without Stirring Arrangement Without Racks And Thermometer. Instrument Should Have Lift Up Bath Cover; Carrier Racks Should Be Given For Flasks And Test Tubes Racks. A Cock Should Be Provided To Facilitate Draining Of Bath Contents. Water Bath Protective Media Should Be There To Prevent Contamination And Formation Of Algae., 14. Magnetice Stirrer Maximum Stirring Speed 1200 Rpm. Heating Capacity 600W Hotplate Size 175Mm Dia. Supply 220/240V, 50Hz,Ac Ho Plate Should Be Chemically Resistant To Acid And Alkali Top Plate Material Stainless Steel. Stirring Unit Should Be Enclosed, Controls Both Hotplate And Stirrer Should Be Provided With Suitable Indicators. Necessary Electrical Cables Should Be Provided.,

Key Value

Document Fees
INR 550 /-
EMD
INR 20000.0 /-
Tender Value
Refer document

BOQ Items

Sl No Item Code Item Name Item Description Unit Quantity
1
01/TEND/2020/RK/497/01 Laboratory Bacteriological incubator Double wall chambers inner made of stainless steel Outer body of Mild steel sheet duly powder coated with 2 1/2 thick glass wool insulation. Temperature is controlled by an imported thermostat to a maximum of 80 C with an accuracy of +1 C Working temperature range 37 C to 80 C Three chambers, removable shelves Should have effective capacity minimum 50 liters. Air ventilators to be provided on both sides The equipment to be provide with control panel having a thermostat control knob, on-off switch pilot lamp and timer, digital indicator Temperature homogeneity Between top and bottom shelves should be maintained Sine 24 X24 X 24 Specification: V
Nos
1
2
01/TEND/2020/RK/497/02 Orbital Shaking Incubator Brushless induction Motor with variable frequency drives operations Step less variable Frequency drive ensures gentle shaking start and maintains set speed Counter balanced mechanism for high stability in uneven load of different sized flasks Universal Shaking Platform to accommodate different sized assorted flasks Maximum shaking capacity 5 Flasks x 1000 ml Powerful fan motor for forced air circulation to maintain uniform conditions inside chamber Specification: As specified in the tender document.
Nos
2
3
01/TEND/2020/RK/497/03 Refrigerated Centrifuges Base Unit Table top high speed refrigerated centrifuge with option of fixed angle as well as swing out rotos. Should give max speed of 14,000 rpm/max ref of 20,000Xg or above with fixed The blower unit should create a suction pressure thro ugh the primary filter (or ore filter), which removes dust particles of above 10 micron size in the first stage. Subsequently, the filtered air passed to the HEPA filters, where the particles or Substances of 0.3 micron size and above are removed. Finally the ultra clean filtered Air supplied to the working chamber as a uniform airflow to perform precision Analysis activates. Cabinet (Material of construction): The system should have Laminar Air Flow Cabinet should have fully enclosed bench designed. The Laminar flow bench should have Stainless Steel SS 304 table with MS Coated tabular frame and body. Laminated unit should also have stand by control system with lock and key. Unit: The unit should have Door should be made of tempered safety glass sliding door or glass wind screen Should have LED display to show measured parameters like stage velocity, total Using time, UV/FI lamp on/off Unit should have Differential pressure indicator. Cleanliness level: The system should have Class 100 (ISO 5 for particle sizes 0.5 u <3530 particles/M3 of air at both at Rest& Operation Condition as per ISO 14644 1 Working size: 4 ft x 2 ft x 2 ft Work table: oIt should have IS 304 Grade Stainless Steel with Finish 4 polish surface Front door 5 mm thick clear Acrylic Sheet- Vertical sliding Direction of flow: Horizontal Airflow Speed : Velocity should have 90 Feet/Minute=20/ Specification: As specified in the tender document.
Nos
1
4
01/TEND/2020/RK/497/04 Refrigerator 250 Liters, double door, inbuilt stabilizer, stand Specification: As specified in the tender document.
Nos
3
5
01/TEND/2020/RK/497/05 UV Visible Spectometer Optical Design iv File Holder for measurement of direct transmittance of films Warranty 03 yers of warranty Specification: As specified in the tender document.
Nos
2
6
01/TEND/2020/RK/497/06 Conductivitity Meter Conductivity meter with conductivity. Cell for the Conductivity meter, COND/TDS Electrode. Specification: As specified in the tender document.
Nos
1
7
01/TEND/2020/RK/497/07 Autoclave Design: Unit made of SS 304 chamber, Lid made of heavy gauge lid, die pressed S.S.304 with pressure gauge Steam release valve & necessary Safety valves, with foot lifting arrangement to open lid, programmable, with all functional accessories The sterilization chamber should be made of corrosion resistant stainless steel Unit: Should have water inlet and outlet valves. Should have a water level gauge Should have gauge for measuring inner and outer steam pressure. Should have an inner temperature indicator. Should have automatic pressure control switch safety valve and eject valve. should have joint less silicone gasket. Should have automatic low water protection Specification: As specified in the tender document.
Nos
1
8
01/TEND/2020/RK/497/08 Haemometer Counting Chamber/square HB tube,20 ul H.B Pipette, Rebber Tube with mouth piece, Cleaning Brush, glass Droper with rubber teat, Glass rod Specification: As specified in the tender document.
Nos
5
9
01/TEND/2020/RK/497/09 Haemocytomer Conting Chamber with RBC and WBC pipette, complete set Specification: As specified in the tender document.
Nos
1
10
01/TEND/2020/RK/497/10 Sonicator Power Rating : 700 wats (150 warts) Frequency : 20 kHz Programmability. 10 memories plus sequencing Programmable Timer. 72 hours Adjustable Pulse On/Off: I second to 24 hours Dimensions (WxLxH): 8 x 15.25 x 8.5 in (203 x 387 x216 mm) Voltage: 110V,50.160 Hz Specification: As specified in the tender document.
Nos
1
11
01/TEND/2020/RK/497/11 Muffle Furnance Max Temperature 9000C Working temp 8000C, Heating Element silicon Carbide (SIC), Temperature Controller PID controller, Display LED/LCD Display, External Chamber Construction MS w/Powder Coating/304 Grade Stainless Steel (Optional). Internal Chamber Construction Ceramic Board & Grooved Refractory Chamber as per Temp. Requirement, Insulation Ceramic wool insulation, Alarm Audible & Visual type, Power Supply 220/440 Volts, Certification ISO, CE & GMP, Stabilizer As standard. Specification: As specified in the tender document.
Nos
2
12
01/TEND/2020/RK/497/12 Homogenizer Rotor speed reange- form 500 upto 30,000 rpm Quick coupling for dispersing aggregates. Interchangeable dispersing aggregates in EC design between approx, 0.1ml and 250 ml Control knob and speed scale. Voltage 220V + 10% Specification: As specified in the tender document.
Nos
2
13
01/TEND/2020/RK/497/13 Water Bath Material of construction: o It should be Double walled inside stainless steel and outside mild steel sheet painted in epoxy powder coating (rust resistant material) with lid Capacity of 325x250x100mm. Unit: Bath should consist of two pilot lamp, temperature control knob and ON/OFF Switch to work on 220/230 volts AC supplied with or without stirring Arrangement without racks and thermometer. Instrument should have lift up bath cover; Carrier racks should be given for flasks and test tubes racks. A cock should be provided to facilitate draining of bath contents. Water bath protective media should be there to prevent contamination And formation of algae. Specification: As specified in the tender document.
Nos
1
14
01/TEND/2020/RK/497/14 Magnetice Stirrer Maximum Stirring Speed 1200 rpm. Heating Capacity 600w Hotplate Size 175mm dia. Supply 220/240V, 50HZ,AC Ho Plate Should be chemically resistant to acid and alkali Top Plate Material Stainless steel. Stirring Unit Should be enclosed, Controls both hotplate and stirrer should be provided with suitable indicators. Necessary electrical cables should be provided. Specification: As specified in the tender document.
Nos
1