Implementation Of System Strengthening Phase-Ii Under Ipds For Additional 6 ( Six ) Towns In Manipur .
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Jan 2021
0 days left
EMD
5 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
As per NIT → Manipur
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Implementation Of System Strengthening Phase-Ii Under Ipds For Additional 6 ( Six ) Towns In Manipur .
BOQ
| Name of Work: Implementation of System Strengthening Phase-II under IPDS for additional 6(Six) towns in Manipur. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Supply | |||
| 2 | 2 | New 11 KV line using ACSR Rabbit (4.8 Km) | |||
| 3 | 3 | 9.0 m Steel Tubular Pole (410:SP-31) | item1 | 96 | Nos. |
| 4 | 4 | Galvanised Pole top bracket | item2 | 68 | Nos. |
| 5 | 5 | Galvanised Clamp for Pole top Bracket | item3 | 136 | Nos. |
| 6 | 6 | Galvanised Cross arm(75X40)mm | item4 | 68 | Nos. |
| 7 | 7 | Galvanised Back clamp for X-arm | item5 | 68 | Nos. |
| 8 | 8 | Galvanised 2x2.2m D.P. channel X-arm (75X40)mm | item6 | 14 | Set |
| 9 | 9 | 11 KV Disc. Composite/Polymer Insulator (Complete set i/c Tension clamps,Hardware) | item7 | 87 | Nos. |
| 10 | 10 | 11 KV Pin Composite/Polymer Insulator (Complete with Pin ) | item8 | 243 | Nos. |
| 11 | 11 | ACSR Conductor (Rabbit) | item9 | 15.12 | Km |
| 12 | 12 | 11 KV AB Switch/G.O. Switch with Galvanised X-arm etc. | item10 | 4 | Set |
| 13 | 13 | Stay Set complete with stay wire, base plate, stay rod etc. | item11 | 72 | Set |
| 14 | 14 | Galvanised Stay Clamp | item12 | 72 | Set |
| 15 | 15 | Galvanised Bracing for D.P.structure, 50X50X6mm M.S. Angle | item13 | 14 | Set |
| 16 | 16 | Galvanised Clamp for D.P. Bracing | item14 | 56 | Nos. |
| 17 | 17 | Galvanised Anti climbing device complete | item15 | 96 | Nos. |
| 18 | 18 | Earthing set complete with G.I. wire | item16 | 82 | Set |
| 19 | 19 | Guarding at crossing with G.I. wire | item17 | 4.8 | Km |
| 20 | 20 | Nuts, Bolts, MS flat as support for item No. 3 jointing sleeves etc.@7kg/km | item18 | 34 | Kg |
| 21 | 21 | Al. Binding wire, UPG clamps etc. @10 kg/km | item19 | 48 | Kg |
| 22 | 22 | Sundries like pole painting Danger plate etc. | item20 | 4.8 | Km |
| 23 | 23 | Installation of Distribution Transformer | |||
| 24 | 24 | Installation of New Distribution Transformer of 250 KVA (10 Nos.) | |||
| 25 | 25 | 9.0 m Steel Tubular Pole (410:SP-31) | item21 | 20 | Nos. |
| 26 | 26 | Galvanised Channel 100X50,@ 7.9 Kg/m 2.8X2 for supporting Transformer | item22 | 10 | Set |
| 27 | 27 | Galvanised Clamp for transformer base channel for M.S. flat [email protected]/m 0.27mX2. | item23 | 20 | Set |
| 28 | 28 | Galvanised Channel 100X50,@7.9 Kg/m 2.8X2 for D.P. X-arm | item24 | 10 | Set |
| 29 | 29 | Galvanised Channel 100X50,@7.9 Kg/m 0.46X2 for supporting of item 2 | item25 | 10 | Set |
| 30 | 30 | Galvanised Channel 75X40,@5.7Kg/m 2X2.8m for HG fuse unit & A.B. switch | item26 | 20 | Set |
| 31 | 31 | Galvanised Clamp for A.B. switch/HG Fuse/DO Fuse, 50X8mm @ 3.1Kg/m 0.23mX2=0.46m. | item27 | 80 | Set |
| 32 | 32 | Galvanised Channel 75X40,@5.7Kg/m 2X0.5m for supporting H.G. fuse main channel X-arm | item28 | 30 | Set |
| 33 | 33 | Galvanised Angle (50X50X6)mm 2.8X2 @ 4.5 Kg/m transformer belting and Angle (35X35X5),0.46X2 @ 2.6 Kg/m. Transformer belting support. | item29 | 10 | Set |
| 34 | 34 | Galvanised Clamp for transformer belting | item30 | 20 | Set |
| 35 | 35 | Distribution transformer 250 KVA as per IS:1180(2014) level-II | item31 | 10 | Nos. |
| 36 | 36 | A.B.Switch | item32 | 10 | Nos. |
| 37 | 37 | Horn gap fuse unit/D.O. fuse, 3 -Ph | item33 | 10 | Set |
| 38 | 38 | DTR Cubicle for DTRs (Comprising of requisite and adequate ratings of MCCBs/MCBs for LT protection in incomer and outgoing along with accessories required. | item34 | 10 | Nos. |
| 39 | 39 | 1.1KV grade, 3½ core 120 Sq.mm PVC insulated aluminium power cable | item35 | 100 | m |
| 40 | 40 | D.B.box Galvanised cross arm of M.S. Angle 35X35X5mm @ 2.6Kg/m 2.8X2 = 5.6m | item36 | 10 | Set |
| 41 | 41 | Galvanised Clamp for DB Box Cross arm | item37 | 20 | Set |
| 42 | 42 | Sub-Station Earthing (set of 3 Earthing Pipe) | item38 | 10 | Nos. |
| 43 | 43 | 3 phase Tri-vector Energy meter comprising of IS 14697-1999 with Kiosk | item39 | 10 | Nos. |
| 44 | 44 | Danger board & Sign Board | item40 | 10 | Nos. |
| 45 | 45 | 11 KV lightening arrestor | item41 | 30 | Nos. |
| 46 | 46 | 11 KV Disc. Composite/Polymer Insulator (Complete set i/c Tension clamps,Hardware) | item42 | 30 | Nos. |
| 47 | 47 | Bolts,Nuts,clamps etc.@5kg/DTR | item43 | 50 | Kg |
| 48 | 48 | Sundries, Pole painting etc. | item44 | 10 | Nos. |
| 49 | 49 | Installation of New Distribution Transformer of 100 KVA (4 Nos) | |||
| 50 | 50 | 9.0 m Steel Tubular Pole (410:SP-31) | item45 | 8 | Nos. |
| 51 | 51 | Galvanised Channel 100X50,@ 7.9 Kg/m 2.8X2 for supporting Transformer | item46 | 4 | Set |
| 52 | 52 | Galvanised Clamp for transformer base channel for M.S. flat [email protected]/m 0.27mX2. | item47 | 8 | Set |
| 53 | 53 | Galvanised Channel 100X50,@7.9 Kg/m 2.8X2 for D.P. X-arm | item48 | 4 | Set |
| 54 | 54 | Galvanised Channel 100X50,@7.9 Kg/m 0.46X2 for supporting of item 2 | item49 | 4 | Set |
| 55 | 55 | Galvanised Channel 75X40,@5.7Kg/m 2X2.8m for HG fuse unit & A.B. switch | item50 | 8 | Set |
| 56 | 56 | Galvanised Clamp for A.B. switch/HG Fuse/DO Fuse, 50X8mm @ 3.1Kg/m 0.23mX2=0.46m. | item51 | 32 | Set |
| 57 | 57 | Galvanised Channel 75X40,@5.7Kg/m 2X0.5m for supporting H.G. fuse main channel X-arm | item52 | 12 | Set |
| 58 | 58 | Galvanised Angle (50X50X6)mm 2.8X2 @ 4.5 Kg/m transformer belting and Angle (35X35X5),0.46X2 @ 2.6 Kg/m. Transformer belting support. | item53 | 4 | Set |
| 59 | 59 | Galvanised Clamp for transformer belting | item54 | 8 | Set |
| 60 | 60 | Distribution transformer 100 KVA as per IS:1180(2014) level-II | item55 | 4 | Nos. |
| 61 | 61 | A.B.Switch | item56 | 4 | Nos. |
| 62 | 62 | Horn gap fuse unit/D.O. fuse, 3 -Ph | item57 | 4 | Set |
| 63 | 63 | DTR Cubicle for DTRs (Comprising of requisite and adequate ratings of MCCBs/MCBs for LT protection in incomer and outgoing along with accessories required. | item58 | 4 | Nos. |
| 64 | 64 | 1.1KV grade, 3½ core 120 Sq.mm PVC insulated aluminium power cable | item59 | 40 | M |
| 65 | 65 | D.B.box Galvanised cross arm of M.S. Angle 35X35X5mm @ 2.6Kg/m 2.8X2 = 5.6m | item60 | 4 | Set |
| 66 | 66 | Galvanised Clamp for DB Box Cross arm | item61 | 8 | Set |
| 67 | 67 | Sub-Station Earthing (set of 3 Earthing Pipe) | item62 | 4 | Nos. |
| 68 | 68 | 3 phase Tri-vector Energy meter comprising of IS 14697-1999 with Kiosk | item63 | 4 | Nos. |
| 69 | 69 | Danger board & Sign Board | item64 | 4 | Nos. |
| 70 | 70 | 11 KV lightening arrestor | item65 | 12 | Nos. |
| 71 | 71 | 11 KV Disc. Composite/Polymer Insulator (Complete set i/c Tension clamps,Hardware) | item66 | 12 | Nos. |
| 72 | 72 | Bolts,Nuts,clamps etc.@5kg/DTR | item67 | 20 | Kg |
| 73 | 73 | Sundries, Pole painting etc. | item68 | 4 | Nos. |
| 74 | 74 | Arial Bunched Cable | |||
| 75 | 75 | New LT Line Using 3 phase 4 wire with AB Cable (3x70+1x50)Sq.mm (6.0 Km.) | |||
| 76 | 76 | 8.0 m S.T.P.(410:SP-14) | item69 | 168 | Nos. |
| 77 | 77 | M.S. cross arm (75X40) mm, 500 mm long | item70 | 168 | Nos. |
| 78 | 78 | Back clamp for cross arm | item71 | 168 | Nos. |
| 79 | 79 | Dead end fittings for AB Cable with Insulated messenger wire complete with Eye hook as per Construction Standards : | item72 | 24 | Nos. |
| 80 | 80 | Suspension fittings for AB Cable with Insulated messenger wire complete with Eye hook as per Construction Standards : | item73 | 144 | Nos. |
| 81 | 81 | AB Cable (3x70+1x50)Sq.mm with insulated messenger/Neutral | item74 | 6 | Km |
| 82 | 82 | Insulation piercing connector suitable for AB Cable (50/35 Sq.mm. Main & Branch) as per TS & Construction Standard {Main 16-95 Sq. mm Service: 4-35(50) Sq. mm & Neutral 16-95 Sq. mm Service: 2-15 Sg. Mm)} | item75 | 300 | Set |
| 83 | 83 | Earthing set complete with G.I. wire. | item76 | 48 | Set |
| 84 | 84 | G.I. wire. No 10 S.W.G. (90 Kg. per 1.09Km.) | item77 | 120 | Kg |
| 85 | 85 | Stay set complete with stay wire and insulator clamp etc. | item78 | 36 | Set |
| 86 | 86 | Bolts & Nuts with [email protected]/km | item79 | 45 | Kg |
| 87 | 87 | Sundaries,Pole painting, Danger plate, Number Plate etc. | item80 | 6 | Km |
| 88 | 88 | New LT Line Using 3 phase 4 wire with AB Cable (3X50+1x35)Sq.mm (3.0 Km.) | |||
| 89 | 89 | 8.0 m S.T.P.(410:SP-14) | item81 | 75 | Nos. |
| 90 | 90 | M.S. cross arm (75X40) mm, 500 mm long | item82 | 75 | Nos. |
| 91 | 91 | Back clamp for cross arm | item83 | 75 | Nos. |
| 92 | 92 | Dead end fittings for AB Cable with Insulated messenger wire complete with Eye hook as per Construction Standards : | item84 | 12 | Nos. |
| 93 | 93 | Suspension fittings for AB Cable with Insulated messenger wire complete with Eye hook as per Construction Standards : | item85 | 63 | Nos. |
| 94 | 94 | AB Cable (3x50+1x35)Sq.mm with insulated messenger/Neutral | item86 | 3 | Km |
| 95 | 95 | Insulation piercing connector suitable for AB Cable (50/35 Sq.mm. Main & Branch) as per TS & Construction Standard {Main 16-95 Sq. mm Service: 4-35(50) Sq. mm & Neutral 16-95 Sq. mm Service: 2-15 Sg. Mm)} | item87 | 150 | Set |
| 96 | 96 | Earthing set complete with G.I. wire. | item88 | 24 | Set |
| 97 | 97 | G.I. wire. No 10 S.W.G. (90 Kg. per 1.09Km.) | item89 | 60 | Kg |
| 98 | 98 | Stay set complete with stay wire and insulator clamp etc. | item90 | 18 | Set |
| 99 | 99 | Bolts & Nuts with [email protected]/km | item91 | 22.5 | Kg |
| 100 | 100 | Sundaries,Pole painting, Danger plate, Number Plate etc. | item92 | 3 | Km |
| 101 | 101 | New LT Line Using 1 phase 2 wire with AB Cable (1X16+1x25)Sq.mm (5.0 Km.) | |||
| 102 | 102 | 8.0 m S.T.P.(410:SP-14) | item93 | 110 | Nos. |
| 103 | 103 | M.S. cross arm (75X40) mm, 500 mm long | item94 | 110 | Nos. |
| 104 | 104 | Back clamp for cross arm | item95 | 110 | Nos. |
| 105 | 105 | Dead end fittings for AB Cable with Insulated messenger wire complete with Eye hook as per Construction Standards : | item96 | 20 | Nos. |
| 106 | 106 | Suspension fittings for AB Cable with Insulated messenger wire complete with Eye hook as per Construction Standards : | item97 | 90 | Nos. |
| 107 | 107 | AB Cable (1x35+1x25)Sq.mm with insulated messenger/Neutral | item98 | 5 | Km |
| 108 | 108 | Insulation piercing connector suitable for AB Cable (50/35 Sq.mm. Main & Branch) as per TS & Construction Standard {Main 16-95 Sq. mm Service: 4-35(50) Sq. mm & Neutral 16-95 Sq. mm Service: 2-15 Sg. Mm)} | item99 | 250 | Set |
| 109 | 109 | Earthing set complete with G.I. wire. | item100 | 30 | Set |
| 110 | 110 | G.I. wire. No 10 S.W.G. (90 Kg. per 1.09Km.) | item101 | 100 | Kg |
| 111 | 111 | Stay set complete with stay wire and insulator clamp etc. | item102 | 20 | Set |
| 112 | 112 | Bolts & Nuts with [email protected]/km | item103 | 37.5 | Kg |
| 113 | 113 | Sundaries,Pole painting, Danger plate, Number Plate etc. | item104 | 5 | Km |
AI Tender Summary
Tender Timeline
Jan 02, 2021
11:30 IST
Tender Published
Tender notice published.
CompletedJan 27, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 28, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender