Repairs And Maintenance Of Ceiling Fan Wall Mounted Fans Electric Geysers Electric Meter Solar Water Heater And Connected Works At Ins Kalinga Ins Karna And Nad Bheemunipatnam Visakhapatnam, Garrison Engineer P Navy Kalinga Visakhapatnam-Andhra Pradesh

Military Engineer Services-MES has published Repairs And Maintenance Of Ceiling Fan Wall Mounted Fans Electric Geysers Electric Meter Solar Water Heater And Connected Works At Ins Kalinga Ins Karna And Nad Bheemunipatnam Visakhapatnam. Submission Date for this Tender is 22-01-2021. Energy Meter Tenders in Garrison Engineer P Navy Kalinga Visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

26468996
Corrigendum : Repairs And Maintenance Of Ceiling Fan Wall Mounted Fans Electric Geysers Electric Meter Solar Water Heater And Connected Works At Ins Kalinga Ins Karna And Nad Bheemunipatnam Visakhapatnam
Open Tender
Indian
Andhra Pradesh
Garrison Engineer P Navy Kalinga Visakhapatnam
22-01-2021

Tender Details

Repairs And Maintenance Of Ceiling Fan Wall Mounted Fans Electric Geysers Electric Meter Solar Water Heater And Connected Works At Ins Kalinga Ins Karna And Nad Bheemunipatnam Visakhapatnam

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Jan-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-01-2021
2 15-Jan-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-01-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 23200.0 /-
Tender Value
INR 11.60 Lakhs /-

BOQ Items

Name of Work : REPAIRS AND MAINTENANCE OF CEILING FAN, WALL MOUNTED FANS, ELECTRIC GEYSERS, ELECTRIC METER, SOLAR WATER HEATER AND CONNECTED WORKS AT INS KALINGA, INS KARNA AND NAD BHEEMUNIPATNAM VISAKHAPATNAM
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Checking of ceiling fan 1200mm sweep at site when and where required as MES complaint slip on daily basis if required except Sunday and holidays in existing position including Supply and fixing as replacement at site in position ceiling fan condensor 2.5 mfd all as specified and as directed. 550 Each Job
2 2 All as per item No. 1 here-in-before but ceiling fan 1400mm sweep when and where required as MES complaint slip on daily basis if required except Sunday and holidays and ceiling fan condensor 3.15 mfd all as specified and as directed. 110 Each Job
3 3 Taking down carefully existing ceiling fan of any sweep and any make after disconnecting the electrical connections, dismantling the blades and removing fan including blades to the workshop including cleaning and dismantling the fan into parts and segregation of unserviceable parts, replacement of unserviceable spare parts with new parts including necessary machining works and lubricating with approved grade of grease and necessary minor soldering work (if required) and re-assembling the fan complete and testing and refixing the fan in same position including all electrical connections and material and labour for replacement of two nos split pins, one connection block and one rubber reel complete all as specified and as directed. 540 Each Job
4 3.1 Note:-\n(i) Rewinding work of armature (if any) shall be measured and paid separately\n(ii) New spare parts required for replacing old burnt out parts other than connector, split pins, connection block and rubber reel shall be measured and paid separately under relevant item as supply only.\n(iii) Labour cost for replacing spare parts are deemed to be inclusive in the quoted rate of item No. 3.00
5 4 Taking down carefully existing exhaust fan of size upto 300 mm sweep and any make after disconnecting the electrical connections and removing the exhaust fan with blades to the workshop including cleaning of dust and dismantling the fan into parts and segregation of unserviceable parts, replacement of unserviceable spare parts with new parts including necessary machining works and lubricating with approved grade of grease and necessary minor soldering work (if required) and re-assembling the fan complete, testing and refixing the fan in same position including all electrical connections and material and labour for replacement of one connection block complete all as specified and as directed. 110 Each Job
6 4.1 Note :-\n(i) Rewinding work (if any) shall be measured and paid separately\n(ii) New spare parts required for replacing old burnt out parts other than connector shall be measured and paid separately under relevant item as supply only.\n(iii) Labour cost for replacing spare parts are deemed to be inclusive in the quoted rate of item No. 4.00
7 5 All as per Item No. 4 here-in-before but for exhaust fan of size upto 540 mm sweep complete all as specified and as directed.\n 20 Each Job
8 6 Taking down and refixing after repair air circulation fan of any make/ model and sweep in its original position, connecting and testing complete all as specified and as directed. 30 Each Job
9 7 Taking down and refixing after repair wall mounted fan of any make/ model and sweep in its original position, connecting and testing complete all as specified and as directed. 20 Each Job
10 8 Taking down and refixing after repair pedestal fan of any make/ model and sweep in its original position, connecting and testing complete all as specified and as directed. \nNote for Item Nos. 6.00 to 8.00 : Bearing/ Gun metal bush/ rubber bush & bolts/ capacitor/ rewinding/ flexible cord/ shaft etc will be measured and paid separately. 15 Each Job
11 9 M&L for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for 1200 mm sweep fan with new super enamelled copper wire of existing gauge including supply and fixing necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing complete all as specified and as directed. 440 Each Job
12 10 All as per Item No. 9 here-in-before but for ceiling fan of size 1400 mm sweep complete all as specified and as directed.\n 90 Each Job
13 11 All as per Item No. 9 here-in-before but for exhaust fan of size upto 300 mm sweep complete all as specified and as directed.\n 10 Each Job
14 12 All as per Item No. 9 here-in-before but for exhaust fan of size upto 400/450 mm sweep complete all as specified and as directed.\n 15 Each Job
15 13 All as per Item No. 9 here-in-before but for wall mounted fan of size upto 400/450 mm sweep complete all as specified and as directed.\n 10 Each Job
16 14 All as per Item No. 9 here-in-before but for air circulator/ pedestal fan of size 450 mm sweep complete all as specified and as directed.\n 10 Each Job
17 15 All as per Item No. 9 here-in-before but for flame proof ceiling fan of size 1200/ 1400 mm sweep complete all as specified and as directed.\n 15 Each Job
18 16 All as per Item No. 9 here-in-before but for flame proof exhaust fan of size 400/ 450 mm sweep complete all as specified and as directed.\n 5 Each Job
19 17 All as per Item No. 9 here-in-before but for flame proof wall mounted fan of size 400/450 mm sweep complete all as specified and as directed.\n 10 Each Job
20 18 Supply only ball bearing, bearing No. 6201/ 6202 for ceiling / exhaust fan complete all as specified and as directed. 530 Each
21 19 Supply only ball bearing, bearing No. 6203/ 6204 for ceiling / exhaust fan complete all as specified and as directed. 65 Each
22 20 Supply only oil filled capacitor of 2.15 mfd suitable for ceiling fan complete all as specified and as directed. 540 Each
23 21 Supply only oil filled capacitor of 3.15 mfd suitable for ceiling fan complete all as specified and as directed. 125 Each
24 22 Supply only gun metal bush suitable for ceiling fan/wall mounting fan/exhaust fan/pedestal fan of any sweep complete all as specified and as directed by the Engineer-in-Charge. 100 Each
25 23 Supply only mounting clamp assembly for ceiling fan of 1200 mm/ 1400 mm sweep with amp, blot, nut, washers, safety/ split pins and rubber bush complete all as specified and as directed. 530 Each
26 24 Supply only MS down rod 15mm bore and 450mm long including two coats of synthetic enamel paint over one coat of red oxide primer for ceiling fan of 1200 mm/ 1400 mm sweep complete all as specified and as directed. 160 Each
27 25 S&F electronic deluxe rotary step type fan regulator including taking down old unserviceable one complete all as specified and as directed. 90 Each
28 26 S&F modular step type fan regulator 120W, 2 module complete all as specified and as directed. 20 Each
29 27 M&L for cleaning/preparation of surfaces of ceiling fan 1200mm/ 1400mm sweep thoroughly and painting with one coat of spray painting using synthetic enamel white paint over the existing paint and writing of serial/ MES number with black paint having each letters/figures in Block of height n.exc 2 cm over it complete all as specified and as directed by the Engineer-in-Charge. 140 Each Job
30 28 All as per Item No. 27 here-in-before but for painting to exhaust fan with blade of any size complete all as specified and as directed.\n 20 Each Job
31 29 All as per Item No. 27 here-in-before but for painting to air circulator/ pedestal fan of 400 mm sweep complete all as specified and as directed.\n 20 Each Job
32 30 S&F in repair louver shutters for exhaust fan of size upto 450 mm sweep suitable for any make made of MS sheet including two coats of synthetic enamel paint over a coat of red oxide primer and bolt, nut, washer etc including taking down old unserviceable one complete all as specified and as directed. 10 Each
33 31 Supply only cord flexible copper conductor three core 23/0.0076 Sqmm PVC insulated sheathed 1100 V grade complete all as specified and as directed by the Engineer-in-Charge.\n 180 RM
34 32 M&L for comprehensive repair/ maintenance of storage type electric water heater (geyser) vertical or horizontal type of capacity 25 ltrs comprising of the following :- 40 Each Job
35 32.1 (a) Inspection, taking down, opening or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank upto the satisfaction of the Engr-in-Charge.
36 32.2 (b) Checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc in situ to ensure free movement of the parts including supply and replacing then washers/ gasket nut etc.
37 32.3 (c) Checking and rectifying earth continuity of the electrical circuits of the geyser and power point.
38 32.4 (d) Checking and refixing thermostat and re-adjust
39 32.5 (e) De-scaling the immersion type heating element and siphon assembly with diluted hydro chloric acid or clear pedette solution.
40 32.6 (f) Checking of indicator lamp for its serviceability
41 32.7 (g) Re-assembling the Geyser, re-install and testing complete.
42 32.8 Note : Parts/ components of geysers found unserviceable shall be replaced by the contractor. New parts/ components required shall be measured and paid separately under Item No. 34 to 43 here-in-after as supply only and labour charges required for replacement are deemed to be included in the quoted rate of item No. 32
43 33 M&L for comprehensive repair/ maintenance of solar water heater (geyser) horizontal type of capacity 100/500 ltrs comprising of the following :- 20 Each Job
44 33.1 (a) Inspection, taking down, opening or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank upto the satisfaction of the Engr-in-Charge.
45 33.2 (b) Checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc in situ to ensure free movement of the parts including supply and replacing then washers/ gasket nut etc.
46 33.3 (c) Checking and refixing solar flat plate collector/ tube collector and re-adjust
47 33.4 (d) De-scaling the immersion type heating element and siphon assembly with diluted hydro chloric acid or clear pedette solution.
48 33.5 Note : Parts/ components of geysers found unserviceable shall be replaced by the contractor. New parts/ components required shall be measured and paid separately under item No. 34 to 43 here-in-after as supply only and labour charges required for replacement are deemed to be included in the quoted rate of item No. 33
49 34 Supply only thermostat of Type EST 11/ 20 A, 250 volt of approved make and having ISI marked complete all as specified and as directed. 40 Each
50 35 All as per item No. 34 here-in-before but for Type EST 7/ 5 A, 250 volt of approved make and having ISI marked complete all as specified and as directed. 20 Each
51 36 Supply only heating element of capacity 2 KW AC 240 volts suitable for storage type electric water heater as per site requirement (press type/ screw type/ triangular/ circular base or ceramic cartige type), ISI marked complete all as specified and as directed. 40 Each
52 37 Supply only heating element of capacity 2/3 KW AC 240 volts suitable for storage type solar water heater as per site requirement (press type/ screw type/ triangular/ circular base or ceramic cartige type), ISI marked complete all as specified and as directed. 20 Each
53 38 All as per item No. 37 here-in-before but of capacity 1.5 KW AC 240 volts ISI make and as per sample complete all as specified and as directed. 20 Each
54 39 Supply only copper siphon assembly suitable for 25 ltrs capacity geysers of any make as required at site of approved make complete with inlet and outlet and provision for thermostat pipe with drain pipes with drain plug, screws, studs, clamp for fixing heating element etc including gasket complete all as specified and as directed. 20 Each
55 40 Supply only plug top 3-pin 15 Amps ISI marked complete all as specified and as directed. 45 Each
56 41 Supply only PVC insulated PVC sheathed flexible round stranded copper conductor of size 2.5 sqmm, 3 core complete all as specified and as directed. 90 RM
57 42 Supply only LED Neon type indicator lamp 240 Volt AC suitable for 25/50 ltrs geyser complete all as specified and as directed. 30 Each
58 43 Supply only safety valve/high pressure release valve with ISI marked suitable for 25/50 ltrs geyser complete all as specified and as directed. 28 Each
59 44 S&F earth plug socket with MCB DP 20 Amps including taking down old unserviceable one complete all as specified and as directed. 15 Each
60 45 S&F 2 pin earth plug top upto 20 Amp complete all as specified and as directed. 25 Each
61 46 M&L for tracing and arresting of leakage in storage tank of 25 ltrs capacity geysers by brazing and soldering at leakage point and testing on completion complete all as specified and as directed. 25 Each Job
62 47 Taking down Geyser of capacity 25 ltrs from its existing position after disconnecting inlet and outlet water connection including M&L for spray painting to Geysers of capacity 25 ltrs with one coat of Ist grade synthetic enamel paint of approved tint after preparation of old steel surfaces including writing serial / MES number (with black colour paint with each letters/ figures (in Block) of height n. exc 2 cm) and refixing the Geysers to its existing position on completion of painting including making inlet/outlet water connection and testing complete all as specified and as directed. 15 Each Job
63 48 S&F in repair PVC connection pipe with two brass adaptors 450mm long & fixing in position including taking out old unserviceable one complete all as specified and as directed. 11 Each
64 49 S&F in repair chromium plated connection pipe for hot water of length upto 600 mm, with two brass connecting nut with gasket and connecting up including taking out old unserviceable one complete all as specified and as directed. 16 Each
65 50 S&F in repair non-return valve, ISI marked 15mm dia including connection complete all as specified and as directed. 20 Each
66 51 S&F water heater (Geyser) storage capacity 25 ltrs vertical type 5 star rated alongwith electric wiring 04 Nos GI Anchor bolts 10mm dia, 100mm long nuts and washer and connecting pipe for outlet and inlet water from geyser complete all as specified and as directed. 7 Each
67 52 S&F Anchor bolts of size 10mm dia, 100mm long including nuts and washer for mounting the geyser complete all as specified and as directed. 31 Each
68 53 S&F MS ceiling fan hook suitable for hanging ceiling fan complete all as specified and as directed. 50 Each
69 54 S&F PVC Exhaust fan of size 200 mm sweep, 230 volt AC with connection from existing ceiling rose with louver shutter complete all as specified and as directed. 7 Each
70 55 S&F PVC Exhaust fan of size 250 mm sweep, 230 volt AC with connection from existing ceiling rose with louver shutter complete all as specified and as directed 6 Each
71 56 S&F exhaust fan metal body heavy duty with louver shutter of sweep 300 mm, 230 volt, SP 1400 RPM with all nut bolt and other accessories with cutting a hole and making good after fixing of exhaust fan including taking out old unserviceable one and depositing to MES store yard complete all as specified and directed. \n(Make : Havells Cat Part No. Turbojet SP or equivalent as approved by GE) 7 Each
72 57 S&F exhaust fan metal body heavy duty with louver shutter of sweep 380 mm, 230 volt, SP 1400 RPM with all nut bolt and other accessories with cutting a hole and making good after fixing of exhaust fan including taking out old unserviceable one and depositing to MES store yard complete all as specified and directed. \n(Make : Havells Cat Part No. Turbojet SP or equivalent as approved by GE) 5 Each
73 58 S&F exhaust fan metal body heavy duty with louver shutter of sweep 450 mm, 230 volt, SP 1400 RPM with all nut bolt and other accessories with cutting a hole and making good after fixing of exhaust fan including taking out old unserviceable one and depositing to MES store yard complete all as specified and directed. \n(Make : Havells Cat Part No. Turbojet SP or equivalent as approved by GE) 2 Each
74 59 S&F AC Single phase static Electronic KWH energy meter of accuracy class 1.0, 240 volt, 50 Hz , with Backlite LCD display ,optical port of rating 10-60 amp 06 months history with transparent hinge type box all as specified and as directed. \n(Make : L&T Cat Part No. WM101BC7DDH or equivalent as approved by GE) 12 Each
75 60 S&F AC Three phase static Electronic KWH energy meter of accuracy class 1.0, 240v, 50 HZ , with Backlite LCD display of rating 10-60 amp six months history with transparent hinge type box all as specified and as directed. \n(Make : L&T Cat Part No. WR300BC73BOXH or equivalent as approved by GE) 4 Each
Disclaimer :