Council Of Scientific And Industrial Research-CSIR has published Turnkey Project For Design And Development Of Bsl-2 Facility For Research And Diagnostic Testing On Covid-19 Samples By Supply, Installation, Testing, Commissioning And Integrating Necessary Infrastructure (Detail Specifications/Requirement As Per Chapter. Submission Date for this Tender is 21-01-2021. Footwears Tenders in CSIR-National Chemical Laboratory, Pune Maharashtra. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 12-Jan-2021 | Amendment in BOQ | BOQ | 21-01-2021 |
Name of Work: Turnkey Project for design and development of BSL-2 facility for Research and diagnostic testing on COVID-19 samples by supply, installation, testing, commissioning and integrating necessary infrastructure (Detail specifications/requirement as per Chapter 4 of Tender) | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Price for Turnkey Project for design and development of BSL-2 facility for Research and diagnostic testing on COVID-19 samples by supply, installation, testing, commissioning and integrating necessary infrastructure (Detail specifications/requirement as per Chapter 4 of Tender) | |||
2 | 1.01 | Site preparation and shifting | Item 1 | 1 | LPS |
3 | 1.02 | Providing first class brick masonry | Item 2 | 4.5 | M3 |
4 | 1.03 | Plastering | Item 3 | 40 | M2 |
5 | 1.04 | Providing and fixing green marble in a single frame | Item 4 | 20 | RM |
6 | 1.05 | Epoxy flooring | Item 5 | 226 | Sq.M |
7 | 1.06 | Epoxy coving | Item 6 | 186 | RM |
8 | 1.07 | Pencil coving | Item 7 | 160 | RM |
9 | 1.08 | Plumbing works | Item 8 | 1 | LPS |
10 | 1.09 | SITC of \nPower and Lighting Distribution Board with Metal door\n | Item 9 | 1 | No |
11 | 1.1 | SITC of \nUPS LDB - Lighting Distribution Board with Metal door\n | Item 10 | 1 | No |
12 | 1.11 | SITC of \nUPS PDB - Power Distribution Board with Metal door\n | Item 11 | 1 | No |
13 | 1.12 | SITC of \nMAIN PDB - Power Distribution Board with Metal door\n | Item 12 | 1 | No |
14 | 1.13 | SITC of \nAutomatic Change Over Switch 200A 4P\n\n | Item 13 | 1 | No |
15 | 1.14 | SITC of Chemical Earthing | Item 14 | 3 | No |
16 | 1.15 | SITC of \n25 x 6 Cu Strip with PVC insulation tape \n | Item 15 | 150 | Mtr |
17 | 1.16 | SITC of \n14 SWG Bare Cu. Wire \n | Item 16 | 75 | Mtr |
18 | 1.17 | SITC of \n12 SWG Bare Cu. Wire \n | Item 17 | 25 | Mtr |
19 | 1.18 | SITC of \n8 SWG Bare Cu. Wire \n | Item 18 | 25 | Mtr |
20 | 1.19 | SITC of Point Wiring-Mains/Sub mains Circuit Wiring using 3x2.5 sqmm | Item 19 | 550 | Mtr |
21 | 1.2 | SITC of Point Wiring-Primary Light point wiring using 3x1.5 sqmm | Item 20 | 300 | Mtr |
22 | 1.21 | SITC of Point Wiring-Secondary Light point wiring using 3x1.5 sqmm | Item 21 | 285 | Mtr |
23 | 1.22 | SITC of Point Wiring-3.5 core, 25sqmm PVC insulated XLPE Armard cable | Item 22 | 10 | Mtr |
24 | 1.23 | SITC of Main Wiring for Power using 3x2.5 sqmm Cu FR wire in 25mm PVC conduit, 3 Run x 2.5 Sq. mm FR wire, Without accessories such as switch, sockets etc.\nMake: Polycab/RR/Havells\n | Item 23 | 175 | Mtr |
25 | 1.24 | SITC \n1 module MS box and PVC Cover Plate + GI Back Box\n | Item 24 | 4 | No |
26 | 1.25 | SITC \n2 module MS box and PVC Cover Plate + GI Back Box\n\n | Item 25 | 6 | No |
27 | 1.26 | SITC \n3 module MS box and PVC Cover Plate + GI Back Box\n\n | Item 26 | 50 | No |
28 | 1.27 | SITC \n6 module MS box and PVC Cover Plate + GI Back Box\n | Item 27 | 5 | No |
29 | 1.28 | SITC \n8 module MS box & PVC Cover Plate + GI Back Box\n\n | Item 28 | 3 | No |
30 | 1.29 | SITC \n6/16A Modular SOCKET\n\n | Item 29 | 47 | No |
31 | 1.3 | SITC \n32A SOCKET\n | Item 30 | 10 | No |
32 | 1.31 | SITC \n16A MCB 1 Module\n | Item 31 | 53 | No |
33 | 1.32 | SITC \n40A MCB 1 Module\n | Item 32 | 34 | No |
34 | 1.33 | SITC of \n6A Modular Switch on existing Modular Plate \n | Item 33 | 50 | No |
35 | 1.34 | SITC of \n16A Modular Switch on existing Modular Plate \n | Item 34 | 47 | No |
36 | 1.35 | SITC of \n6A, 5 Pin Modular Socket\n | Item 35 | 30 | No |
37 | 1.36 | SITC of \n16 Amps, 3-pin single phase industrial socket with plug top\n | Item 36 | 14 | No |
38 | 1.37 | SITC of \n32 Amps, 5-pin (440V) three phase metal clad industrial socket with plug top | Item 37 | 11 | No |
39 | 1.38 | GI PERFORATED TYPE CABLE TRAYS 150 x 50mm, \n | Item 38 | 30 | Mtr |
40 | 1.39 | GI PERFORATED TYPE CABLE TRAYS 100 x 50mm, \n | Item 39 | 45 | Mtr |
41 | 1.4 | GI PERFORATED TYPE CABLE TRAYS 50 x 50mm, \n | Item 40 | 45 | Mtr |
42 | 1.41 | Supply, fabrication, erection and painting of \nmiscellaneous MS items | Item 41 | 1 | Metric Ton |
43 | 1.42 | SITC of bottom opening Light Fixture | Item 42 | 35 | No |
44 | 1.43 | UV lamps for INFECTIOUS ROOM | Item 43 | 8 | No |
45 | 1.44 | Air Conditioning system High wall units 1.00 TR | Item 44 | 2 | No |
46 | 1.45 | Air Conditioning system Cassette AC 1.00 TR | Item 45 | 6 | No |
47 | 1.46 | Air Conditioning system Cassette AC 1.50 TR | Item 46 | 4 | No |
48 | 1.47 | Air Conditioning system Cassette AC 2.00 TR | Item 47 | 5 | No |
49 | 1.48 | Refrigerant piping | Item 48 | 100 | RM |
50 | 1.49 | PVC drain Pipe 3/4" | Item 49 | 125 | RM |
51 | 1.5 | Modular Wall Panels 50 mm thick wall (Excluding doors) | Item 50 | 435 | Sq.M |
52 | 1.51 | GI Powder coated Bottom Track for 50 mm Panel | Item 51 | 160 | RMT |
53 | 1.52 | FALSE CEILING 50 mm thick ceiling | Item 52 | 235 | Sq.M |
54 | 1.53 | GI Powder Coated Ceiling T Channels | Item 53 | 275 | RMT |
55 | 1.54 | Extruded Aluminum Powder Coated /\nAnodized R42 clip on type covings\n | Item 54 | 600 | RMT |
56 | 1.55 | Aluminum Powder Coated / \nAnodized 3 D internal Corner Piece\n | Item 55 | 70 | No |
57 | 1.56 | External Pillar For 50 mm Wall | Item 56 | 50 | RMT |
58 | 1.57 | External Corner For 50 mm Wall | Item 57 | 20 | No |
59 | 1.58 | View Panel-Panel Size is 1800 mm x 600 mm = 1.08 sqm | Item 58 | 5 | No |
60 | 1.59 | View Panel-Panel Size is 1800 mm x 1200 mm = 2.16 sqm | Item 59 | 1 | No |
61 | 1.6 | View Panel-Panel Size is 1200 mm x 600 mm = 0.72 sqm | Item 60 | 4 | No |
62 | 1.61 | View Panel-Panel Size is 1200 mm x 1200 mm = 1.44 sqm | Item 61 | 3 | No |
63 | 1.62 | CUTOUTS IN WALL and CEILING PANEL - Providing cutouts in ceiling panels for light fixtures and HEPA boxes, etc.. | Item 62 | 50 | No |
64 | 1.63 | CUTOUTS IN WALL and CEILING PANEL -Cut-outs in wall Panels for Electrical Sockets (approx.) | Item 63 | 50 | No |
65 | 1.64 | Door Size: \n1000 x 2100 mm single Leaf\n | Item 64 | 10 | No |
66 | 1.65 | Door Size: \n1500 X 2100 mm Double Door\n | Item 65 | 4 | No |
67 | 1.66 | Door Size: \n1500 X 2100 mm Double Door, \nwith panic bar (EMERGENCY)\n | Item 66 | 1 | No |
68 | 1.67 | Double Skin Dynamic Pass-Box -(WXDXH In mm) 550x550x550 | Item 67 | 2 | No |
69 | 1.68 | Double Skin Dynamic Pass-Box -(WXDXH In mm) 450x450x450 | Item 68 | 1 | No |
70 | 1.69 | Double Skin Static Pass-Box (WXDXH In mm) 300x300x300 | Item 69 | 3 | No |
71 | 1.7 | Integrated Air Shower | Item 70 | 1 | No |
72 | 1.71 | SS 4 Leg Table with SS TOP: 1700 mm W X 750mm D X 750mm H\n | Item 71 | 1 | No |
73 | 1.72 | SS 4 leg Table with SS TOP: 1500mm W X 750mm D X 750mm H\n | Item 72 | 2 | No |
74 | 1.73 | SS 4 Leg Table with SS TOP: 1400mm W X 750mm D X 750mm H\n | Item 73 | 2 | No |
75 | 1.74 | SS 4 Leg Table with SS TOP: 1200mm W X 750mm D X 750mm H\n | Item 74 | 2 | No |
76 | 1.75 | SS Overhead Storage Cabinet: 750mm W X 450mm D X 750mm H | Item 75 | 11 | No |
77 | 1.76 | SS Tall storage Cabinet: 900mm W X 450mm D X 2100mm H\n\n | Item 76 | 4 | No |
78 | 1.77 | SS gowning cupboard: 900mm W X 450mm D X 2100mm H\n\n | Item 77 | 2 | No |
79 | 1.78 | MS Glassware Storages: 914mmW X 406mmD X 2133mmH\n | Item 78 | 2 | No |
80 | 1.79 | Desktop workstation made out of 25mm particle board top with 50x50mm MS Powder coated legs along with glass above top, MSCP square pipe under structure below top. Workstations should have Metal Cable riser and cable tray for wire management.\nSize: 900mm L X 600 mm W X 750 mm H\n | Item 79 | 3 | No |
81 | 1.8 | Executive mid back chair for data center\n\n | Item 80 | 5 | No |
82 | 1.81 | Used Linen Bin 100 L capacity\n | Item 81 | 1 | No |
83 | 1.82 | Wall mounted and elbow operated bottle stand for holding one 0.5 L bottle | Item 82 | 4 | No |
84 | 1.83 | Shoe Rack, suitable for atleast 6 pairs\nDimensions: 1200 mm L X 300 mm W X 600 mm H \nM.O.C.: S.S. 304 qlty*18 Swg, Mirror Finish\n | Item 83 | 4 | No |
85 | 1.84 | Shoe Cover Dispenser unit standard\nApprox. dimensions: 470 x 260 x 170 mm | Item 84 | 3 | No |
86 | 1.85 | Crossover bench with space for shoes\nDimensions: 1350 mm L X 300 mm W X 550 mm H \n\n | Item 85 | 1 | No |
87 | 1.86 | Crossover bench with space for shoes\nDimensions: 1500 mm L X 300 mm W X 550 mm H \n\n | Item 86 | 1 | No |
88 | 1.87 | SS paddle dustbin (round with lid)\nDimensions: 375 mm W X 600 mm H\nS.S. 304 qlty* 18 Swg, Mirror Finish\n | Item 87 | 7 | No |
89 | 1.88 | Lab Stool with medium back support | Item 88 | 10 | No |
90 | 1.89 | SS trolley, with 100 litre basket | Item 89 | 2 | No |
91 | 1.9 | SS 304 Locker Full length, with 6 compartments. 2100 mm x 1200 mm x 450 mm | Item 90 | 1 | No |
92 | 1.91 | Steel Vertical Filing Cabinet | Item 91 | 3 | No |
93 | 1.92 | Signages | Item 92 | 20 | No |
94 | 1.93 | Biosafety Cabinet Class II Type A2 \n(Make: Thermo/ESCO/Micro-Filt/Dyna Filter/Klenzaid)\ | Item 93 | 4 | No |
95 | 1.94 | 2-8 Deg C refrigerator Minimum 200 Ltr\n(Make: Celfrost/Thermolab/Panasonic) | Item 94 | 2 | No |
96 | 1.95 | 2-8 Deg C refrigerator Minimum 1400 Ltr\n(Make: Celfrost/Thermolab/Panasonic) | Item 95 | 1 | No |
97 | 1.96 | -20 Deg C freezer\nMinimum 350 Ltrs, (Make: Celfrost/HAIER/Panasonic) | Item 96 | 2 | No |
98 | 1.97 | -80 Deg freezer Minimum 420 Ltr (Make: Blue Star /HAIER/Panasonic)\n\n | Item 97 | 1 | No |
99 | 1.98 | Refrigerated micro centrifuge\n(Make: Thermo/ Cole Parmer / Eppendorf / Ika) | Item 98 | 2 | No |
100 | 1.99 | Safety cabinet for storing flammable solvents | Item 99 | 1 | No |
101 | 2 | Vortex shaker\n(Make: Thermo/ Cole Parmer / Eppendorf / Ika) | Item 100 | 4 | No |
102 | 2.01 | Dry bath | Item 101 | 2 | No |
103 | 2.02 | Digital Autoclave 75 liters\n(Make: Medica/ Machin Fabrik ) | Item 102 | 2 | No |
104 | 2.03 | Micropipette set Electronic\n(Make: Gilson /Cole Parmer / Eppendorf / Ika) | Item 103 | 4 | Sets |
105 | 2.04 | Washer & Dryer Machine \n(Make: LG/Godrej/Samsung/IFB) | Item 104 | 1 | No |
106 | 2.05 | Oxygen Depletion Detector | Item 105 | 1 | No |
107 | 2.06 | CCTV-Supply and Installation of HD DOME/Bullet Camera \n | Item 106 | 8 | No |
108 | 2.07 | Supply and Installation of 8 CHANNEL DVR | Item 107 | 1 | No |
109 | 2.08 | Supply and Installation SMPS: Power Supply of required capacity\n | Item 108 | 8 | No |
110 | 2.09 | Supply and Installation of camera cabling | Item 109 | 100 | Mtr |
111 | 2.1 | Monitor for viewing 43" | Item 110 | 1 | No |
112 | 2.11 | SITC of Access control System | Item 111 | 4 | No |
113 | 2.12 | Interlocks for 4 doors of Infectious Airlocks 1 and 2, facility entry door and washroom | Item 112 | 4 | No |
114 | 2.13 | Thermal Camera with facial recognition for one of the reader | Item 113 | 1 | No |
115 | 2.14 | SITC of Fire Alarm System | Item 114 | 1 | No |
116 | 2.15 | Digital addressable microprocessor - controlled Fire Alarm Control Panel (1 Loop) | Item 115 | 1 | No |
117 | 2.16 | Addressable digital type smoke detectors with indicating LED, mounting base etc. | Item 116 | 15 | No |
118 | 2.17 | Response indicators | Item 117 | 5 | No |
119 | 2.18 | Manual call points pull stations of approved make with NO/NC contacts | Item 118 | 3 | No |
120 | 2.19 | Hooter with relay module | Item 119 | 2 | No |
121 | 2.2 | Control module for Hooter | Item 120 | 1 | No |
122 | 2.21 | Addressable relay module to trip the Air handling units (AHU), Access controlled door, Gas Suppression Systems, etc. | Item 121 | 1 | No |
123 | 2.22 | SITC of 2C X 1.5 Sq.mm., XLPE insulated, copper conductor, armored, twisted pair, FRLSZH, cable with all wiring accessories such as GI Saddle, GI Spacer, grips, cable tie Aluminum clamps clamped to structural beam/ column for Loop/ Zone/ Communication Wiring (RED color) \n\n | Item 122 | 225 | RM |
124 | 2.23 | SITC of PA System-Rack Mounted Power Amplifier with battery backup (100 watts) | Item 123 | 1 | No |
125 | 2.24 | SITC of PA System--6W Ceiling Mounted Speakers with excellent speech & (For False Ceiling Area) Power Tapping - 6/3/1.5 | Item 124 | 8 | No |
126 | 2.25 | SITC of Microphone | Item 125 | 1 | No |
127 | 2.26 | SITC of microphone/speaker wire and necessary wiring | Item 126 | 50 | Mtr |
128 | 2.27 | SITC of Label and Barcode Printer | Item 127 | 1 | No |
129 | 2.28 | SITC of handheld barcode scanner | Item 128 | 4 | No |
130 | 2.29 | SITC of “All-in-One” PC | Item 129 | 3 | No |
131 | 2.3 | SITC of Network color Laser Printer-Scanner-Copier | Item 130 | 1 | No |
132 | 2.31 | SITC of Network monochrome Laser printer | Item 131 | 1 | No |
133 | 2.32 | SITC of Color Network scanner | Item 132 | 1 | No |
134 | 2.33 | SITC of 20kVA ONLINE UPS | Item 133 | 1 | No |
135 | 2.34 | SITC of Telephone and LAN Cabling- CAT-6 Flexible Cable | Item 134 | 450 | Mtr |
136 | 2.35 | RJ-11 Socket Suitable for CAT 6 cable | Item 135 | 8 | No |
137 | 2.36 | RJ-45 Socket Suitable for CAT 6 cable | Item 136 | 8 | No |
138 | 2.37 | SITC of Telephone wires termination box with Krone modules for 20 lines | Item 137 | 1 | No |
139 | 2.38 | SITC of 6U network rack | Item 138 | 1 | No |
140 | 2.39 | SITC of 24 port PoE network switch with 2 nos. of 1G SFP ports\n | Item 139 | 1 | No |
141 | 2.4 | SITC 802.1 N, Wireless access points with highest throughput\n\n | Item 140 | 3 | No |
142 | 2.41 | SITC of Digital Telephone instrument with digital display, speaker phone facility.\n | Item 141 | 10 | No |
143 | 2.42 | Warranty (Charges if any) | Item 142 | 1 | Year |
144 | 2.43 | Installation and Commissioning (Charges if any) | Item 143 | 1 | No. |
145 | 2.44 | Freight (including Loading & Unloading) & Insurance Charges FOR CSIR-NCL (charges if any) | Item 144 | 1 | No. |
146 | 2.45 | Other Charges, if any | Item 145 | 1 | Nos |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy