Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #26451700

Kiifb - Proposed Construction Of School Building To Pattancherry Govt . High School In Pattancherry Grama Panchayath , Palakkad District .

Issued by Boards / Undertakings / PSU · Palakkad, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
11 Jan 2021
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
2800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Palakkad → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Kiifb - Proposed Construction Of School Building To Pattancherry Govt . High School In Pattancherry Grama Panchayath , Palakkad District .

BOQ

Work Name:KIIFB - Proposed Construction of School Building to Pattancherry Govt. High School in Pattancherry Grama Panchayath, Palakkad District. (School code:21098)
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11SCHOOL BUILDINGBI01010001010000000000000515BI0100001113
21.0012.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soilBI01010001010000000000000515BI0100001114227.011cum
31.0022.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.BI01010001010000000000000515BI0100001115204.474cum
41.0034.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)BI01010001010000000000000515BI010000111628.891cum
51.0047.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)BI01010001010000000000000515BI010000111711.503cum
61.0055.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concreteBI01010001010000000000000515BI0100001118132.165sqm
71.0065.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantileversBI01010001010000000000000515BI0100001119504.355sqm
81.0075.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and StrutsBI01010001010000000000000515BI0100001120413.88sqm
91.0085.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platformBI01010001010000000000000515BI0100001121541.604sqm
101.0095.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)BI01010001010000000000000515BI0100001122131.522sqm
111.015.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI010000112335.478cum
121.0115.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal sizeBI01010001010000000000000515BI010000112450.234cum
131.0125.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).BI01010001010000000000000515BI0100001125130.511cum
141.0135.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or moreBI01010001010000000000000515BI010000112623824.8kilogram
151.01450.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc completeBI01010001010000000000000515BI0100001127137.372cum
161.01550.6.2.2 : Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc completeBI01010001010000000000000515BI010000112817.598cum
171.01650.9.1.3 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). using good quality Vengai woodBI01010001010000000000000515BI01000011290.427cum
181.01750.9.2.3 : Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction of Engineer in -charge.using Vengai woodBI01010001010000000000000515BI010000113025.2sqm
191.01850.9.4.3 : Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows ( Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Vengai woodBI01010001010000000000000515BI010000113121.49sqm
201.0199.74.1 : Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mmBI01010001010000000000000515BI010000113220no
211.029.100.1 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mmBI01010001010000000000000515BI010000113320no
221.02110.26.1 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tubeBI01010001010000000000000515BI01000011341036.8kg
231.0229.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etcBI01010001010000000000000515BI01000011351395kg
241.02321.1.1.1 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)BI01010001010000000000000515BI0100001136209.25kg
251.02421.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thicknessBI01010001010000000000000515BI010000113769.75sqm
261.02513.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)BI01010001010000000000000515BI0100001138541.604sqm
271.02613.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).BI01010001010000000000000515BI01000011392100.64sqm
281.02713.9.1 : Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plasterBI01010001010000000000000515BI0100001140294.034sqm
291.02811.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.BI01010001010000000000000515BI0100001141588.51sqm
301.02913.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primerBI01010001010000000000000515BI01000011422642.24sqm
311.0313.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new workBI01010001010000000000000515BI01000011432642.24sqm
321.03113.50.1 : Applying priming coat:With ready mixed pink or Grey primer of approved and manufacture on wood work (hard and soft wood)BI01010001010000000000000515BI010000114456.7sqm
331.03213.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new workBI01010001010000000000000515BI010000114556.7sqm
341.03313.65.1 : Painting with black anti- corrosive bitumastic paint of approved brand and manufacture to give an even shade:Two or more coats on new workBI01010001010000000000000515BI0100001146129.89sqm
351.03422.6 : Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)BI01010001010000000000000515BI0100001147185.92sqm
361.03513.71 : Lettering with black Japan pint of approved brand and manufactureBI01010001010000000000000515BI01000011481800per Letter per cm height
372RAMPBI01010001010000000000000515BI0100001149
382.0012.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soilBI01010001010000000000000515BI01000011502.52cum
392.0027.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)BI01010001010000000000000515BI01000011514.41cum
402.00311.3.1 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregateBI01010001010000000000000515BI01000011528.4sqm
412.00410.26.1 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tubeBI01010001010000000000000515BI010000115383kg
423ElectrificationBI01010001010000000000000515BI0100001154
433.001od830710/2020_2021 : Supply of all materials and labour charges of point wiring for 240V AC circuits through existing PVC conuduits using 1.5 Sq.mm FRLS PVC insulated flexible copper wire along with 1.5 Sq.mm FRLS PVC insulated flexible copper wire for continuous earthing with modular switch, modular base, cover plate,&lt;br&gt;suitable GI box etc. (excluding 1.5 Sq.mm FRLS PVC insulated flexible copper wire circuit mains) for the following:One exhaust fan point controlled by one No. 6A SP switch.&lt;br&gt;BI01010001010000000000000515BI010000115512no
443.002od830711/2020_2021 : Supply and installation of 20W LED (2000 Lumens) 4 feet tube fitting with 2kV&lt;br&gt;surge protection and 160-360V voltage protection or equivalent on wall/ ceiling.BI01010001010000000000000515BI010000115651no
453.003od830712/2020_2021 : Supply and installation of 10W LED wall lamps.BI01010001010000000000000515BI01000011574no
463.004od830713/2020_2021 : Supply and Installation of 48&quot; ceiling fan with standard length of down rodBI01010001010000000000000515BI010000115818no
473.005od830714/2020_2021 : Supply, installation, testing and commissioning of wall mounted type double door dust tight and vermin proof IP43 Rated Horizontal 6way TPN MCB DB (DB-1) consists of the following: Single phase / three phase MCB distribution board, 415/240V on surface or recess complete with tinned copper phase and neutral bus bars, earth bar, detachable gland plate, interconnections, phosphated and powder painted including earthing, etc. as required with suitable MCB / RCCB / Isolator&lt;br&gt;6 way (8+18), TPN, MCB DB, double door, horizontal typeBI01010001010000000000000515BI01000011591no
483.006od830715/2020_2021 : Supply and wiring of circuits for power plugs / circuit mains through existing PVC&lt;br&gt;conduit concealed as following:2 runs of 1.5 Sq.mm FRLS PVC insulated flexible copper wire along with 1.5 Sq.mm PVC insulated flexible copper wire for continuous earthing through existing 20mm PVC conduit.BI01010001010000000000000515BI0100001160443.8metre
493.007od830716/2020_2021 : Supply and wiring of circuits for power plugs / circuit mains through existing PVC&lt;br&gt;conduit concealed as following:2 runs of 2.5 Sq.mm FRLS PVC insulated flexible copper wire along with 1 run of 1.5 Sq.mm flexible copper wire through existing 20mm PVC conduit.BI01010001010000000000000515BI010000116170metre
503.008od830801/2020_2021 : Supply and fixing of power sockets, controlling Modular type switches, and&lt;br&gt;mounting boxes.Supply and fixing of 16A independent switch and socket on&lt;br&gt;suitable size G.I. boxBI01010001010000000000000515BI010000116212no
513.009od830719/2020_2021 : Supply of all materials and labour charges of point wiring for 240V AC circuits&lt;br&gt;through existing PVC conuduits using 1.5 Sq.mm FRLS PVC insulated flexible&lt;br&gt;copper wire along with 1.5 Sq.mm FRLS PVC insulated flexible copper wire for&lt;br&gt;continuous earthing with modular switch, modular base, cover plate, suitable GI box etc. (excluding 1.5 Sq.mm FRLS PVC insulated flexible copper wire circuit mains) for the following:Two light point controlled by one No. 6A SP switch.BI01010001010000000000000515BI010000116320no
523.01od830720/2020_2021 : Supply of all materials and labour charges of point wiring for 240V AC circuit through existing PVC conuduits using 1.5 Sq.mm FRLS PVC insulated flexible&lt;br&gt;copper wire along with 1.5 Sq.mm FRLS PVC insulated flexible copper wire for&lt;br&gt;continuous earthing with modular switch, modular base, cover plate, suitable GI box etc. (excluding 1.5 Sq.mm FRLS PVC insulated flexible copper wire circuit mains) for the following:Three light point controlled by one No. 6A SP switch.BI01010001010000000000000515BI01000011643no
533.011od830782/2020_2021 : Supply of all materials and labour charges of point wiring for 240V AC circuits&lt;br&gt;through existing PVC conuduits using 1.5 Sq.mm FRLS PVC insulated flexible&lt;br&gt;copper wire along with 1.5 Sq.mm FRLS PVC insulated flexible copper wire for&lt;br&gt;continuous earthing with modular switch, modular base, cover plate, suitable GI box etc. (excluding 1.5 Sq.mm FRLS PVC insulated flexible copper wire circuit mains) for the following:One fan point controlled by one switch using step type electronic regulator.BI01010001010000000000000515BI010000116518no
543.012od830722/2020_2021 : Supplying and fixing of following sizes of medium class 32mm Dia PVC conduit&lt;br&gt;along with accessories in surface/recess including&lt;br&gt;cutting the wall and making good the same in case of recessed conduit as required.32 mm dia. ISI marked, PVC conduit, medium classBI01010001010000000000000515BI010000116626metre
553.013od830723/2020_2021 : Supply and laying / fixing, giving and termination of the following copper conductor&lt;br&gt;/ strips for effective earthing of the system as per IS 3043.BI01010001010000000000000515BI010000116745metre
563.014od830768/2020_2021 : Supply and providing efficient 1500mm long, 38mm dia. G.I. Pipe earthing&lt;br&gt;including filling the pit with charcoal and salt. 1500mm long, 38mm dia. G.I. Pipe&lt;br&gt;earthing including filling the pit with charcoal and salt.&lt;br&gt;BI01010001010000000000000515BI01000011683no
573.0151.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mmBI01010001010000000000000515BI0100001169916metre

AI Tender Summary

OUR REF NO 26451700
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 11-01-2021
Authority
Authority Name Kerala Institute Of Local Administration
Work Description Kiifb - Proposed Construction Of School Building To Pattancherry Govt . High School In Pattancherry Grama Panchayath , Palakkad District .
Basic Detail
Tender No 86/CL23/CMPMU/KILAKIIFB/20-21
Bidding Type Tender
Location
City Palakkad
State Kerala
Key Dates
Publish Date 31 Dec 2020
Submission Date 11 Jan 2021
Open Date 15 Jan 2021
Finance
Tender Value Ref. Documents
Tender Fee 2800
EMD 50000
Exemption Not Available
Document List
Tendernotice_1.pdf
undertakingofcompositetender.pdf
appdtenderdocument.pdf
epaymentform.pdf
BOQ_573110.xls
KILAPRELIMINARYAGREEMENT.pdf
7B31C0CD-AC74-4366-A233-79821AEDF8CA.html
specialconditions.pdf
DECLARATION.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 31, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 11, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 15, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

pdf

undertakingofcompositetender.pdf

pdf

appdtenderdocument.pdf

pdf

epaymentform.pdf

xls

BOQ_573110.xls

pdf

KILAPRELIMINARYAGREEMENT.pdf

html

7B31C0CD-AC74-4366-A233-79821AEDF8CA.html

pdf

specialconditions.pdf

pdf

DECLARATION.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders