Sitar/120L024 Establishment Of Liquid Nitrogen Storage And Nitrogen Gas Distribution Facility At Starc ( Sitar ) , Bangalore
Tender Overview
Project Description
Sitar / 120L024 Establishment Of Liquid Nitrogen Storage And Nitrogen Gas Distribution Facility At Starc ( Sitar ) , Bangalore , Establishment Of Liquid Nitrogen Storage And Nitrgen Gas Distribution Facility At Starc ( Sitar ) , Vertical Cryogenic Tanks - Vacuum + Super Insulated Type With Level Transmitter & Pressure Transmitter . Capacity : Minimum 20Kl - 2Nos . Mawp: Minimum 17 Bar ( As Per Asme Section Viii Division 1 With U Stamp / En13458 ) Atmosperic Vaporizers: Minimum 400Nm3 / Hr - 2Nos . ( As Per Asme Section Viii Division 1 ) Mawp: Minimum 35 Bar Interconnecting Pipes ( Ss 316L Electropolish ) , Cryo Valves And Instruments As Per Oem And Mounting Bolts For Tanks & Vaporizers , 0 . 1 Micron Particle Filter With Isolation Valve And Bypass Line Before The Hooking Point And 5 Micron Or Less Particle Filter With Isolation Valve And Bypass Line After The Vaporizer . , Obtaining Peso Licence For The Liquid Nitrogen Storage Area , Installation & Commissioning Including Liquid Nitrogen For Commissioning Of Tanks
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-Jan-2021 | Extension of Bid Submission date | Date | 01-Feb-2021 |
| 2 | 21-Jan-2021 | Amending Delivery period | Other | 01-Feb-2021 |
| 3 | 30-Jan-2021 | Extension of Bid submission date | Date | 11-Feb-2021 |
| 4 | 12-Feb-2021 | Bid submission date extension | Date | 19-Feb-2021 |
| 5 | 19-Feb-2021 | Extension of Bid submission date 4 | Date | 22-Feb-2021 |
BOQ
| Name of Work: Establishment of Liquid Nitrogen Storage and Nitrgen gas Distribution Facility at STARC (SITAR) | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Establishment of Liquid Nitrogen Storage and Nitrgen gas Distribution Facility at STARC (SITAR) | |||
| 2 | 1.01 | Vertical Cryogenic Tanks - \nVacuum + Super Insulated type with Level Transmitter &\nPressure Transmitter.\n\nCapacity : minimum 20KL - 2Nos.\nMAWP: minimum 17 bar\n(As per ASME Section VIII Division 1 with U stamp/EN13458)\n\nAtmosperic Vaporizers: minimum 400NM3/Hr - 2Nos.(As per ASME Section VIII Division 1)\nMAWP: Minimum 35 bar\n\ninterconnecting pipes (SS 316L electropolish), Cryo valves and instruments as per OEM and mounting bolts for Tanks & Vaporizers | item1 | 1 | Set |
| 3 | 1.02 | 0.1 Micron particle filter with isolation valve and bypass line before the hooking point and 5 Micron or less particle filter with isolation valve and bypass line after the vaporizer. | item2 | 1 | Set |
| 4 | 1.03 | Obtaining PESO Licence for the Liquid Nitrogen Storage Area | item3 | 1 | Set |
| 5 | 1.04 | Installation & commissioning including Liquid Nitrogen for commissioning of Tanks | item4 | 1 | Set |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-5 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
Completed