| 1 | 1 | Dismantling and taking out Pre-Stressed concrete / steel pole of any size including breaking of PCC foundation and earth work etc and removal of debries complete all as specified and directed by Engineer-in-Charge | | 1 | Each |
|---|
| 2 | 2 | Dismantling old unserviceable stay assembly of any size complete all as specified and directed by Engineer-in-Charge | | 10 | Each |
|---|
| 3 | 3 | Dismantling of old unserviceable ACSR conductor of any size for LT overhead line complete all as specified and directed by Engineer-in-Charge | | 4 | Per Qtl |
|---|
| 4 | 4 | Dismantling / taking down cross arms, bracings, support, clamp including nuts, bolts and washers complete all as specified and directed by Engineer-in-Charge | | 3 | Per Qtl |
|---|
| 5 | 5 | Dismantling of insulators LT of any size for removal or refixing at site complete all as specified and directed by Engineer-in-Charge | | 350 | Each |
|---|
| 6 | 6 | Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3½ core complete all as specified and directed by Engineer-in-Charge | | 50 | RM |
|---|
| 7 | 7 | All as per Srl item No. 6 here-in-before but for size 150 sq mm 3½ core complete all as specified and directed by Engineer-in-Charge | | 100 | RM |
|---|
| 8 | 8 | All as per Srl item No. 6 here-in-before but for size 120 sq mm 3½ core complete all as specified and directed by Engineer-in-Charge | | 500 | RM |
|---|
| 9 | 9 | All as per Srl item No. 6 here-in-before but for size 95 sq mm 3½ core complete all as specified and directed by Engineer-in-Charge | | 100 | RM |
|---|
| 10 | 10 | All as per Srl item No. 6 here-in-before but for size 70 sq mm 3½ core complete all as specified and directed by Engineer-in-Charge | | 110 | RM |
|---|
| 11 | 11 | All as per Srl item No. 6 here-in-before but for size 50 sq mm 3½ core complete all as specified and directed by Engineer-in-Charge | | 120 | RM |
|---|
| 12 | 12 | All as per Srl item No. 6 here-in-before but for size 35 sq mm 3½ core complete all as specified and directed by Engineer-in-Charge | | 150 | RM |
|---|
| 13 | 13 | All as per Srl item No. 6 here-in-before but for size 25 sq mm 4 core complete all as specified and directed by Engineer-in-Charge | | 200 | RM |
|---|
| 14 | 14 | All as per Srl item No. 6 here-in-before but for size 16 sq mm 4 core complete all as specified and directed by Engineer-in-Charge | | 1050 | RM |
|---|
| 15 | 15 | All as per Srl item No. 6 here-in-before but for size 16 sq mm 2 core complete all as specified and directed by Engineer-in-Charge | | 300 | RM |
|---|
| 16 | 16 | Excavation in trenches not exceeding 1.5 mtr width and not exceeding 1.5m depth for laying under ground cable in loose/soft soil complete all as specified and directed by Engineer-in-Charge | | 375 | Cum |
|---|
| 17 | 17 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed by Engineer-in-Charge | | 195 | Cum |
|---|
| 18 | 18 | Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge | | 180 | Cum |
|---|
| 19 | 19 | M&L for sand cushioning for protection of PVC cable with screen wash river sand and punning to proper required cover complete all as specified and directed by Engineer-in-Charge | | 150 | Cum |
|---|
| 20 | 20 | M&L for bricks of sub class ‘B’ bricks, for cable protection in trenches laid dry and flat complete all as specified and directed by Engineer-in-Charge | | 15 | Per 1000 Nos |
|---|
| 21 | 21 | M&L for Boring hole across the Road/plinth/hardstanding/path/drain/pavement etc., suitable for inserting HDPE/GI pipe of upto 100mm dia bore pipe for 0.4 mpa working pressure for cable passing without damaging existing Road / path / hard standing / floor by trenchless technology or manual using necessary equipment complete all as specified and directed by Engineer-in-Charge | | 25 | RM |
|---|
| 22 | 22 | M&L for Re-fixing the GI/copper strip of any size with new nut, bolts, washer, replace broken shuddles for lightning protection for hanger's/buildings and brazing work on joints complete all as specified and directed by Engineer-in-Charge | | 10 | RM |
|---|
| 23 | 23 | M&L for re-laying old bricks of any type and size bricks, for cable protection in trenches laid dry and flat complete all as specified and directed by Engineer-in-Charge | | 140 | RM |
|---|
| 24 | 24 | M&L for PCC preparation including cutting up to 45 cm width and depth of the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for the fixing the pipe/laying cables complete all as specified and directed by Engineer-in-Charge | | 2.4 | Cum |
|---|
| 25 | 25 | M&L in repairs for 40mm dia steel tubes (light grade) galvanised with fittings, laid in trenches/wall for protection of underground earth strip when crossing the road/fixing on wall complete all as specified and directed by Engineer-in-Charge | | 12 | RM |
|---|
| 26 | 26 | M&L in repairs for 50mm dia steel tubes (light grade) galvanised with fittings, laid in trenches/wall for protection of underground earth strip when crossing the road/fixing on wall complete all as specified and directed by Engineer-in-Charge | | 6 | RM |
|---|
| 27 | 27 | S & F GI tube light grade galvanised of size 80 mm with all fitting and fixed to wall and celling or laid in floors/under road etc complete all as specified and directed by Engineer-in-Charge | | 6 | RM |
|---|
| 28 | 28 | S & F GI tube light grade galvanised of size 100 mm with all fitting and fixed to wall and celling or laid in floors/under road etc complete all as specified and directed by Engineer-in-Charge | | 6 | RM |
|---|
| 29 | 29 | M&L for disconnecting faulty/burnt end portion of cable by removing the cable from loop including necessary excavation & earth work, relaying and reconnecting the cable by removing faulty/burnt portion of incoming and out going cables at panel boards and preparing fresh terminals with suitable size of thimbles,lugs and glands or gland plates as suitable of any size and number of cables incoming out going at panel board complete all as specified and directed by Engineer-in-Charge | | 5 | Each Job |
|---|
| 30 | 30 | Taking out faulty underground 1100 volt grade LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or rerouting after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required complete all as specified and directed by Engineer-in-Charge\nNote:1. New LT cable replace with fault portion ,joints shall be measured and paid separately under respective items of the schedule.\n2. Retrived old serviceable bricks will be laid in trenches for cable protection. if extra bricks and sand required at site shall be measured and paid separately under respective items of the schdule.\n3. Earth work and excavation will be measured and paid separately under respective items of the schdule. | | 650 | RM |
|---|
| 31 | 31 | Taking down the care fully existing out door/indoor type Old PCC floor mounted LT panel board of size (more than 1.0m x1.0m x 0.5m to 2.0x1.5m x 0.8m) after disconnecting all type of incoming and out going cables, removing carefully switch gears and measuring instruments for reuse/refixing of serviceable items and repair / maintenance and servicing of existing panel by replacing hinges, switch gear compartments with rubber seal, locks, nuts,bolts and washers and provn of danger notice boards, indicators of three nos with colour coding and three phase digital voltmeter 0-500V, Ammeter 0-800A with suitable CT,s and selector switch and tape insulation sleeves the three phases and neautral with colour coading and painted with two coats powder coating primer and also reconnecting all cables in same position with suitable glands,gland plates,aluminium lugs, nut bolts and washers and refixing serviciable switchgears obtained from the panel complete all as specified and directed by Engineer-in-Charge \nNote: Supply and fix Switch gears against unserviceable measured and paid separately with relevent items of this schedule. | | 2 | Each Job |
|---|
| 32 | 32 | M & L for preparation of old painted surfaces of LT panel size (moe than 1.0m,x1.0mx0.5m to 2.0x1.5mx0.8m) and applying spray painting with two coats of synethetic enamel paint over a coat of red oxide primer of existing color for outdoor/indoor panel board, outer & inner side and scraping out the old paint surfaces of existing panel boards complete all as directed by Engineer-in-charge including white wash to panel foundation/PCC base complete all as specified and directed by Engineer-in-Charge | | 2 | Each Job |
|---|
| 33 | 33 | Supply and fix in replacement steel tubular swaged poles complete with cast iron base plate, taper plug, bolts,nuts & screws as specified type 410 SP-31, 9.0 meters long, complete all as specified and directed by Engineer-in-Charge | | 2 | Each |
|---|
| 34 | 34 | M&L for cement concrete in foundations, filling and mass concrete type D2 1:4:8 with 40 mm graded stone aggregate for foundation of pole etc complete all as specified and directed by Engineer-in-Charge | | 3 | Cum |
|---|
| 35 | 35 | M&L for providing cement concrete type B1, 1:2:4 using 20 mm stone aggregate in foundation, roof,kerb or mud stops, rounded or chamfered on edges and coping to pole complete all as specified and directed by Engineer-in-Charge | | 2 | Cum |
|---|
| 36 | 36 | Demolishing the broken earth pit chamber and constructing new earth pit chamber and PCC chamber cover only complete as per SSR Pt -I of 1996 including new wire mesh funnel complete all as specified and directed by Engineer-in-Charge | | 10 | Each Job |
|---|
| 37 | 37 | Supply and fix in repairs LED type street light fitting 60 watt pressure dia cast aluminium housing LED street light luminaries with IP 66 including GI pipe medium grade 40 mm dia bracket bend in 120 degree and clamps,nuts,bolts etc with all acessories complete all as specified and directed by Engineer-in-Charge\nMake : Bajaj Cat No. BRTFG60W LED or equivalent in Philips / Crompton Greaves / Havells or as approved by GE | | 11 | Each |
|---|
| 38 | 38 | S&F 1.5 sqmm 3 core, 1100 volt grade heavy duty cable, PVC insulated copper multistranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed for making connection of street light from FRP junction box/OH line to street lights complete all as specified and directed by Engineer-in-Charge | | 270 | RM |
|---|
| 39 | 39 | Supply and fix in repair hot moulded FRP looping /Junction box size 280 mmx200 mm for street light poles with locking arrangement and suitable connection for three phase incomming cable 3 phase out going cable and single phase connection for light fitting incl controlled MCB SP-10 Amps -01 Nos enclosed in thermo plastic in closed shock proof safe IP-65, weather,vermin proof,dust and water proof complete with two nos cables entry incl gland of standard size with suitable size mild steel clamps to fixed on pole complete all as specified and directed by Engineer-in-Charge | | 35 | Each |
|---|
| 40 | 40 | Disconnecting of LT supply and opening bus bar chamber/ cable box chamber of outdoor/indoor LT panel, removing of burnt out lugs, LT switch gears / MCCB / MCB of any capacity and size and cleaning of bus bar and contact terminals with CTC solutions, insulating the bus bar by taping color codes and making connections complete with necessary nuts, bolts, washeres, thimbles and links of existing size and refixing all switch gears after repair / maintenance / servicing complete all as specified and directed by Engineer-in-Charge | | 2 | Each Job |
|---|
| 41 | 41 | Supply and fix self adhesive reflective radium stickers 75 mm wide around the street light poles 1.5 above ground level complete all as specified and directed by Engineer-in-Charge | | 36 | Each |
|---|
| 42 | 42 | M&L in repairs for straight through cold shrink type joint 1100 Volt complete with jointing material and accessories suitable for 16 to 50 Sqmm 3.5 Core complete all as specified and directed by Engineer-in-Charge | | 8 | Each |
|---|
| 43 | 43 | M&L in repairs for Straight through cold shrink type joint 1100 Volt complete with jointing material and accessories suitable for 70 to 150 Sqmm 3.5 Core complete all as specified and directed by Engineer-in-Charge | | 6 | Each |
|---|
| 44 | 44 | M&L in repais for Straight through cold shrink type joint 1100 Volt complete with jointing material and accessories suitable for 185 to 300 Sqmm 3.5 Core complete all as specified and directed by Engineer-in-Charge | | 4 | Each |
|---|
| 45 | 45 | Supply and fix street light timer enclosed out door box 3 phase,40 Amps, 3 pole , 230 volt Astronomical time switch complete with all accessories i.e MCB 40 Amps TPN, Astronomical time switch 24 Hrs, contactor,fuse unit,indicator lamp,rotary switch and in coming and out going connector etc including prewired complete all as specified and directed by Engineer-in-Charge\nMake: IndoAsian Cat part No. TL040ASO or equivalent make in Havells / L&T / Crompton Greaves / Standard / Siemens or as approved by GE | | 1 | Each |
|---|
| 46 | 46 | M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI earth strip of size 32 x 6 mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion after taking down old earthing complete all as specified and directed by Engineer-in-Charge\nNote : GI strip upto 7.5m including testing consider in this item | | 14 | Each Set |
|---|
| 47 | 47 | M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 20mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion after taking down old earthing complete all as specified and directed by Engineer-in-Charge\nNote : GI wire upto 7.5m including testing consider in this item | | 10 | Each Set |
|---|
| 48 | 48 | S&F cable end jointing kit for LT, 1100 Volt (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 16 to 50 sqmm complete all as specified and directed by Engineer-in-Charge | | 10 | Each |
|---|
| 49 | 49 | All as per Srl item No. 48 here-in-before but for joint of size 70 sqmm to 95 sqmm complete all as specified and directed by Engineer-in-Charge | | 6 | Each |
|---|
| 50 | 50 | All as per Srl item No. 48 here-in-before but for joint of size 120 sqmm to 150 sqmm complete all as specified and directed by Engineer-in-Charge | | 4 | Each |
|---|
| 51 | 51 | All as per Srl item No. 48 here-in-before but for joint of size 185 sqmm to 240 sqmm complete all as specified and directed by Engineer-in-Charge | | 2 | Each |
|---|
| 52 | 52 | Supply & install, commissioning, testing of out door type LT Panel (CPRI approved) of size not less than 1.6 mtr x 1.4 mtr x 0.8 mtr fabricated out of 3.15mm thick CRCA sheet angle size 50 x 50 x 5 mm thick frame factory made totally enclosed dust and vermin proof are side hinged opening arrangement on front back and top with locking arrangement, cable entry and exist from bottom both side and consisting of following accessories complete all as specified and directed by Engineer-in-Charge :- \n(i) INCOMING:\n(a) MCCB 400A,415 Volts 4 pole, 50 KA : 01 No. (b) ADJUSTABLE THERMAL & MAGNETIC TYPE Thermal Release Setting 415 Volts 4 pole 50 KA : 01 No. (c) (Incoming), Indicator lamp LED type (set of three Red, Yellow, Blue) : 01 No.\n(ii) OUTGOING:\n(a) Indicator lamp LED type (set of three Red, Yellow, Blue) : 01 No.\n(b) MCCB 250A, 415 Volts 4 pole 36 KA (ADJUSTABLE THERMAL & MAGNETIC TYPE Thermal Release Setting), 415 Volts 3 pole 36 KA : 02 No., One No. spare for same capacity\n(c) MCCB 63A,415 Volts 4 pole 25 KA :05 No. (ADJUSTABLE THERMAL & MAGNETIC TYPE Thermal Release Setting), (One Spare)\n(d) Copper bus bar 40mmx6mmx1.0mtr long : 04 Nos.\n(e) Copper bus bar 40mmx6mmx0.75 mtr long : 04 Nos.\n(f) Ammeter digital type 0 to 200 Amp with CT of ratio 500/5 Amp complete with sel.ector switch : 01 No.\n(g) Voltmeter digital type0 to 500 Volts with rotary type selector switch : 01 No.\n(h) Digital Type Power Factor meter : 01 No.\n(j) Supply and fixing timer switch / Auto lux astro type (having longitude and latitude of Indian cities in memory) 250 V single phase of 20 Amps rating with Three phase contactor fitted inside steel enclosure \n(k) MCB DP 63 Amps, 16 KA, 220 Volts : 16 Nos. for single phase connections and complete wiring in other compartment | | 2 | Each Job |
|---|
| 53 | 53 | Supply & install, commissioning, testing of out door type LT Panel (CPRI approved) of size not less than 1.5 mtr x 1.2 mtr x 0.6 mtr fabricated out of 3.15mm thick CRCA sheet angle size 50 x 50 x 5 mm thick frame factory made totally enclosed dust and vermin proof are side hinged opening arrangement on front back and top with locking arrangement, cable entry and exist from bottom both side and consisting of following accessories complete all as specified and directee by Engineer-in-Charge :-\n(i) INCOMING:\n(a) MCCB 250A, 415 Volts 4 pole, 50 KA : 01 No. (b) (ADJUSTABLE THERMAL & MAGNETIC TYPE Thermal Release Setting), 415 Volts 4 pole, 50 KA : 01 No. (c) (Incoming) and Indicator lamp LED type (set of three Red, Yellow, Blue) : 01 No.\n(ii) OUTGOING:\n(a) Indicator lamp LED type (set of three Red, Yellow, Blue) : 01 No.\n(b) MCCB 125 A, 415 Volts 4 pole 36 KA (ADJUSTABLE THERMAL & MAGNETIC TYPE Thermal Release Setting), 415 Volts 3 pole 36 KA : 01 No. and one No spare for same capacity\n(c) MCCB 63 A, 415 Volts 4 pole 36 KA (ADJUSTABLE THERMAL & MAGNETIC TYPE Thermal Release Setting), 415 Volts 3 pole 36 KA : 03 Nos. and one No spare for same capacity\n(d) MCCB 40 A, 415 Volts 4 pole 36 KA (ADJUSTABLE THERMAL & MAGNETIC TYPE Thermal Release Setting), 415 Volts 3 pole 36 KA : 03 Nos. and one No spare for same capacity\n(e) Copper bus bar 40mm x 6mm x 1.2mtr long : 04 Nos.\n(f) Copper bus bar 40mm x 6mm x 0.75 mtr long : 04 Nos.\n(g) Ammeter digital type 0 to 200 Amp with CT of ratio 500 / 5 Amp complete with selector switch : 01 No.\n(h) Voltmeter digital type0 to 500 Volts with rotary type selector switch : 01 No.\n(j) Digital Type Power Factor meter : 01 No.\n(k) Supply and fixing timer switch / Auto lux astro type (having longitude and latitude of Indian cities in memory ) 250 V single phase of 20 Amps rating with Three phase contactor fitted inside steel enclosure \n(l) MCB DP 63 Amps, 16 KA, 220 Volts : 16 Nos. for single phase connections and complete wiring in other compartment \n\n\n | | 3 | Each Job |
|---|
| 54 | 54 | Supply & install, commissioning, testing of out door type feeder pillar, LT type (CPRI approved) of size not less than 0.8 mtr x 0.75 mtr x 0.5 mtr fabricated out of 3.15mm thick CRCA sheet angle size 50 x 50 x 5 mm thick frame factory made totally enclosed dust and vermin proof are side hinged opening arrangement on front back and top with locking arrangement, cable entry and exist from bottom both side and consisting of following accessories complete all as specified and directed by Engineer-in-Charge :-\n(i) INCOMING:\n(a) MCCB 125A, 415 Volts 4 pole, 50 KA : 01 No. (b) (ADJUSTABLE THERMAL & MAGNETIC TYPE Thermal Release Setting), 415 Volts 4 pole, 50 KA : 01 No. (c) (Incoming) and Indicator lamp LED type (set of three Red, Yellow, Blue) : 01 No.\n(ii) OUTGOING:\n(a) Indicator lamp LED type (set of three Red, Yellow, Blue) : 01 No.\n(b) MCCB 63 A, 415 Volts 4 pole 36 KA (ADJUSTABLE THERMAL & MAGNETIC TYPE Thermal Release Setting), 415 Volts 3 pole 36 KA : 02 Nos. and one No. spare for same capacity\n(c) MCCB 40 A, 415 Volts 4 pole 36 KA (ADJUSTABLE THERMAL & MAGNETIC TYPE Thermal Release Setting), 415 Volts 3 pole 36 KA : 02 Nos. and one No. spare for same capacity\n(d) Copper bus bar 40mm x 6mm x 1.0mtr long : 04 Nos.\n(e) Copper bus bar 40mm x 6mm x 0.75 mtr long : 04 Nos.\n(f) Ammeter digital type 0 to 200 Amp with CT of ratio 500 / 5 Amp complete with sel.ector switch : 01 No.\n(g) Voltmeter digital type0 to 500 Volts with rotary type selector switch : 01 No.\n(h) Digital Type Power Factor meter : 01 No.\n(j) Supply and fixing timer switch / Auto lux astro type (having longitude and latitude of Indian cities in memory ) 250 V single phase of 20 Amps rating with Three phase contactor fitted inside steel enclosure \n(k) MCB DP 40 Amps, 16 KA, 220 Volts : 16 Nos. for single phase connections and complete wiring in other compartment | | 2 | Each Job |
|---|
| 55 | 55 | M&L for cutting the road / hard standing and making good disturbed surfaces by using PCC type C2 (1:3:6) by using 40mm graded stone aggregate for the fixing the pipe complete all as specified and directed by Engineer-in-Charge.Charge. | | 50 | RM |
|---|
| 56 | 56 | M&L for 75 mm dia HDPE pipes PN 10 with fittings, laid in trenches / wall for protection of underground cable when crossing the road / fixing on wall complete all as specified and directed by Engineer-in-Charge.Charge. | | 3 | RM |
|---|
| 57 | 57 | M&L for 50 mm dia HDPE pipes PN 10 with fittings, laid in trenches / wall for protection of underground cable when crossing the road / fixing on wall complete all as specified and directed by Engineer-in-Charge.Charge. | | 3 | RM |
|---|
| 58 | 58 | M&L for preparation old painted surfaces with synthetic enemel paint to LT steel tubbular pole 8.5/9 mtr long including clamps,brackets,chanel,cross arms,bracing support,pipe of support for cable and swan neck etc including zebra painting at bottom up to 1.5 mtr above from the PCC couping and writing pole No with white paint complete etc complete all as specified and directed by Engineer-in-Charge.Charge.\nNote: Pole number shall be marked with white enamel paint over a base of size 20cm x 20cm on prepared with two coats of black enamel paint on pole surfaces.\n--------------------------------------------------------------------------------------------------------------\nNote : A sum of Rs. 82,450.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 25 (Schedule of Credit) of Tender document\n | | 32 | Each Job |
|---|