| 1 | 1 | Tubewell | 1 | | |
|---|
| 2 | 2 | Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested , equipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect. | 2 | | |
|---|
| 3 | 3 | Boring with 250mm id Housing pipe upto 150m depth BGL. | 3 | 125 | mtr. |
|---|
| 4 | 4 | Supplying, Lowering of MS Pipe as per IS-4270-2001 including MS Socket heving dimansions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. | 4 | | |
|---|
| 5 | 5 | 200mm nominal diameter (weight 41.6 kg per metre) 8.0 mm thickness | 5 | 111 | Mtr |
|---|
| 6 | 6 | Supplying Fixing & lowering of Stainless Steel Cage type wire wound screen as per IS: 8110-2000 or latest ISI Marrked, Duly welded with suitable grade S.S Welding electrode to lower the strainer into tubewell bore. | 6 | | |
|---|
| 7 | 7 | (i) 200mm Steel Strainer (Slot Size 0.15) 6.30 mm thick. | 7 | 10 | Mtr |
|---|
| 8 | 8 | Supplying, fixing and lowering of stainless steel socket as per IS 8110-2000 or latest, ISI Marked duly welded with suitable grade SS welding electrode to lower the strainer into tube well bore complete in all respect. | 8 | | |
|---|
| 9 | 9 | 200 mm internal diameter | 9 | 6 | Each |
|---|
| 10 | 10 | Supplying lowering & fixing of MS special socket to connect S.S Strainer to M.S pipe duly welded with suitable grade welding electrode complete in all respect. | 10 | | |
|---|
| 11 | 11 | ( c) 200mm Internal diameter | 11 | 4 | Each |
|---|
| 12 | 12 | Supplying & fixing of M.S Clamp of size 150mm×12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Sultable size complete in all respect. | 12 | 1 | Each |
|---|
| 13 | 13 | Supplying at site wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore. | 13 | 1 | Each |
|---|
| 14 | 14 | Supplying & fixing of bail plug of M.S pipe complete with intverted U-Hook attached to the bottom plug complete in all respect. | 14 | | |
|---|
| 15 | 15 | ( c) 200nn internal diameter (weight 41.6kg per metre) 8.0 mm thickness | 15 | 4 | Mtr |
|---|
| 16 | 16 | Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. | 16 | | |
|---|
| 17 | 17 | ( c) 200nn internal diameter | 17 | 1 | Each |
|---|
| 18 | 18 | Development and Stabilizing of the tubewell with air compressor of requried capacity as directed by the Engineer-in Charge including cost tools appliances & consumable to the satisfaction of Engineer-in Charge. | 18 | | |
|---|
| 19 | 19 | ( a) Capacity of Air Compressor 300 cfm at 250 PSI | 19 | 10 | Hrs |
|---|
| 20 | 20 | Development of stabillizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. | 20 | 8 | Hrs |
|---|
| 21 | 21 | Collection of Water sample from different strata and testing of sample from approval laboratory (Phisical & Chemical Analysis) | 21 | 3 | Each |
|---|
| 22 | 22 | Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.) | 22 | 1 | Each |
|---|
| 23 | 23 | PUMP CHAMBER AND SANITARY LATRINE | 23 | | |
|---|
| 24 | 24 | Construction of Pump Chamber size 3.05mX3.70m, With gravel pit but including electric wiring as per DWSS standard design & analysis, complete in all respects.\nIncluding provision for Sanitary Latrine in pump Chamber for Foundation and plinth of WC rooms including flooring, PVC pipes, Junction Box, 1 Nos. Leach Pits, Super structure WC Room etc. | 24 | 1 | Job |
|---|
| 25 | 25 | OHSR | 25 | | |
|---|
| 26 | 26 | Constructing one No. of 50 KL (50000 litres) Capacity with sill level not less than 17 m height upto FSL 20 mtr from formation level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single main hole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing C.I / D/F expansion joints latest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, Conforming to ISI - 13382 and C.I/ D/F sluice Valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow CI double flanged pressure pipes C.I horizontally as per IS 7181-1986 and latest duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. TMT steel & painting of all complete shall be included in cost & P/F aluminium leader inside the OHSR complete in all respect as per specifications. (The specifications & drawing are based on safe bearing capacity of soil is less than 8.75 tone per sqm. In case the safe bearing capacity of soil is less than 8.75 tone per Sqm. The contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Preminum including providing and fixing automatic Electronic Water Level control Device and Construction of Plinth protection around OHSR with masonry toe wall with 40 mm thick CC 1:2:4 on top over 100 mm thick CC 1:8:16 & inside earth filling including overflow scower haudi complete in all respects. | 26 | 1 | Each |
|---|
| 27 | 27 | Providing, Stringing out, cutting, Jointing and testing of ISI Marked PVC Pipe (S&S) as per IS 4985 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage. (Manually Excavation and Including specials) | 27 | | |
|---|
| 28 | 28 | 110 mm o/d PVC pipe 10 kgf/cm2 | 28 | 35 | Mtr |
|---|
| 29 | 29 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) Class PN-I as per ISI | 29 | | |
|---|
| 30 | 30 | 80 mm i/d sluice valve Flanged | 30 | 3 | Each |
|---|
| 31 | 31 | 100 mm i/d sluice valve Flanged | 31 | 5 | Each |
|---|
| 32 | 32 | Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department | 32 | | |
|---|
| 33 | 33 | 0.60 x 0.60 m | 33 | 6 | Each |
|---|
| 34 | 34 | 0.90 x 0.90 m | 34 | 2 | Each |
|---|
| 35 | 35 | Distribution System | 35 | | |
|---|
| 36 | 36 | Providing Strining out PVC pipes 6Kgf Cm2 ISI marked as per ISI-4985 the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications for less than 3 mtr. Street width Complete in all respect. Specifications for Manually Excavation including speicals (6kgf/ cm2) Pressure | 36 | | |
|---|
| 37 | 37 | PVC pipe 63 mm o/d | 37 | 690 | Mtr |
|---|
| 38 | 38 | Providing Strining out PVC pipes 6Kgf Cm2 ISI marked as per ISI-4985 the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications for More than 3 mtr street width (Mechanically Excavation and Including specials) (6kgf/ cm2) Pressure | 38 | | |
|---|
| 39 | 39 | PVC pipe 63 mm o/d | 39 | 3128 | Mtr |
|---|
| 40 | 40 | PVC pipe 90 mm o/d | 40 | 754 | Mtr |
|---|
| 41 | 41 | PVC pipe 110mm o/d | 41 | 167 | Mtr |
|---|
| 42 | 42 | Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting and including restoration of roads to orginal Position | 42 | | |
|---|
| 43 | 43 | 63 mm o/d | 43 | 2497 | Mtr |
|---|
| 44 | 44 | 90 mm o/d | 44 | 148 | Mtr |
|---|
| 45 | 45 | Contractor shall quote rates only for dismantling of metalled road and back filling with excavated earth fully compacted. The restoration of the metalled road of its original condition will be done by the concerned department e.e (PWD (B&R) / PMB / Panchayati Raj) | 45 | 1490 | Mtr |
|---|
| 46 | 46 | Dismantling of cement concrete 80 mm thick cement concrete 1:2:4 overe 100 mm thick C.C 1:8:16 and making good the same to its original conditionl complete in all respect. | 46 | 204 | Mtr |
|---|
| 47 | 47 | HOUSE SERVICE CONNECTIONS | 47 | | |
|---|
| 48 | 48 | Providing proposed water connection to house hold up to wall with providing, laying jointing testing GI pipe lines 15mm i/d = 2.50 mtr, B-Class , (Above GL), Providing & fixing MDPE pipe 15 mm i/d with specials 2.00 mtr (Below GL) including cost of specials such as tees, bends, sockets, elbow, etc. cutting, threading and testing in trenches in the ground and ISI 15 mm i/d GM ferrule as per IS: 2692 and 3\" i/d clamp with C.I bib cock, 15 mm i/d as per IS: 210 with stainless steel spindle of approved make | 48 | 230 | Each |
|---|
| 49 | 49 | Water meter | 49 | | |
|---|
| 50 | 50 | Providing and fixing Multijet water meter to household including cost of specials such as tees, bends, sockets, elbow, peet valve, union, nipples and hooks etc. Cutting threading and testing complete in all respect | 50 | 230 | Each |
|---|
| 51 | 51 | CHLORINATION & DISINFECTION | 51 | | |
|---|
| 52 | 52 | Providing, Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS standard specifications. | 52 | 1 | Each |
|---|
| 53 | 53 | Solar Panel Energy | 53 | | |
|---|
| 54 | 54 | Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capaity as per guidelines issued by PEDA complete in all respects. | 54 | 4 | KW |
|---|
| 55 | 55 | Pumping Machinery | 55 | | |
|---|
| 56 | 56 | Providing & installing,testing & commisioning of 1 no electrically driven Submersible Pump set capable of delivering 246 LPM against a head of 65 mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter,Main Switch, VM, AMpere Meter,ELCB, Shunt capacitor. Single phase,preventer,Indicating lamps,Kit-Kat etc. including G.I. column Pipe of IS 1239-2004 medium class suitable size 50 mm & length 50 mtr (in 3mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 100 mtr length and 2.50mm2 size as per IS694-1990 reaffirmed 2000 complete in all respects | 56 | | |
|---|
| 57 | 57 | Rate of Motor with Pump 246 lpm, head 65 mtr | 57 | 1 | Each |
|---|
| 58 | 58 | Panel Board | 58 | 1 | Each |
|---|
| 59 | 59 | Submersible cable Size 2.50mm2 | 59 | 100 | Mtr |
|---|
| 60 | 60 | Column Pipe (G.I) 50 mm i/d | 60 | 50 | Mtr |
|---|
| 61 | 61 | D.I FITTING INSIDE PUMP CHAMBER | 61 | | |
|---|
| 62 | 62 | Providing and installing 100mm dia delivery main (From Tube well to Duck Foot bend including cost of D.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as D.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects. | 62 | 1 | Job |
|---|
| 63 | 63 | Developmet of water works | 63 | | |
|---|
| 64 | 64 | Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing | 64 | 487 | Mtr |
|---|
| 65 | 65 | Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4\" x 4\", size top 3\" x 4\",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects. | 65 | 40 | No |
|---|
| 66 | 66 | Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing | 66 | 30 | No |
|---|
| 67 | 67 | Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing. | 67 | 4 | No |
|---|
| 68 | 68 | Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing complete in all respects. | 68 | 1 | No |
|---|
| 69 | 69 | Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing | 69 | 30 | Mtr |
|---|
| 70 | 70 | Providing & fixing MS Sign Board as per standard size of DWSS as per Drawing D-20 | 70 | 1 | No |
|---|
| 71 | 71 | (Operation & Maintenance Cost Without Electricity Charges) | 71 | | |
|---|
| 72 | 72 | Operation and Maintenance water supply system for 3 Months including operating of machinery , repair of leakages, supplying of full time Pump Operator cum- Chowkidar, supply of Sodium Hypo Chlorite solution for disinfection for 3 months after completion. | 72 | 1 | Job |
|---|
| 73 | 73 | Carriage of material such as Bajri & Sand upto end 0-110 KM \n | 73 | 182.16 | cum |
|---|
| 74 | 74 | Environmental Management | 74 | | |
|---|
| 75 | 75 | Surface dressing of ground including removing rank vegetation and nequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in all kinds of soil. | 75 | 250 | Sqm |
|---|
| 76 | 76 | Supplying and planting permanent trees in prepared pits and watering (Trees like Neem, Ashoka, Dake, Arjun etc.) | 76 | 10 | each |
|---|
| 77 | 77 | Planting ground covers (ordinary) including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 25cm distance from plant to plant and\nrow to row. | 77 | 10 | Sqm |
|---|
| 78 | 78 | Planting seedlings including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of seedlings at 20cm distance from plant to plant and row to row. | 78 | 10 | Sqm |
|---|
| 79 | 79 | Provision for one way stand post with Khura complete in all respects | 79 | 1 | Job |
|---|