Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-03-2021 | 81095 AMDTS TO DATES 6 | Date | 20-03-2021 |
| 2 | 26-02-2021 | 81095 AMDTS TO DATES 5 | Date | 09-03-2021 |
| 3 | 22-02-2021 | 81095 AMDTS TO DATES_4 | Date | 06-03-2021 |
| 4 | 17-02-2021 | 81095 AMDTS TO DATES_3 | Date | 01-03-2021 |
| 5 | 05-02-2021 | 81095 AMDTS TO DATES_2 | Date | 24-02-2021 |
| 6 | 25-01-2021 | 81095 AMDTS TO DATES 1 | Date | 15-02-2021 |
| Name of Work: RE-SURFACING OF MAIN RUNWAY 03/21 INCLUDING SHOULDERS AT ICGAS DAMAN | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | M & L for Preparing old bituminous surfaces by brushing with wire brushes for removing caked mud etc . sweeping with brooms and finally fanning the cleaned surface compressed air through mechanical means to remove all loose dirt etc, and providing Premix Dense Asphaltic Concrete DAC) with grading 1 of IRC 50mm thick (consolidated thickness) in single layer using bitumen of grade PMB-40 with 5.4% minimum binder content (Marshal stability 1200 Kg) mixed by weight of total mix using hot mix plant spread, rolled and consolidated to required gradient and camber complete using necessary mechanical sensor paver and tandem vibratory roller of capacity exceeding 8 tonne but not exceeding 12 tonne capacity over tack coat of Paving Bitumen VG-10 @ 2kg/10 SqM complete all as specified and as directed. Note:- (a) No price adjustment shall be applicable if excess quantity of binder content is used / approved in the execution of work under this item. (b) Cement shall be used as filler as per job mix formula (c) The marshall stability shall be a minimum of 1200 kg.(d) DAC shall be as per MORTH specifications as detailed in particular specifications. | 8278.52 | 10 SQM | |
| 2 | 2 | M & L for Preparing old bituminous surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface compressed air through mechanical means to remove all loose dirt etc, and providing Premix Dense Asphaltic Concrete (DAC) with grading 2 of IRC 50mm thick (consolidated thickness) in single layer using bitumen of grade PMB-40 with 5.6% minimum binder content mixed by weight of total mix (Marshal stability 1400 Kg) using hot mix plant spread, rolled and consolidated to required gradient and camber complete using necessary mechanical sensor paver and tandem vibratory roller of capacity exceeding 8 tonne but not exceeding 12 tonne capacity over tack coat of Paving Bitumen VG-10 @ 2kg/10 SqM complete all as specified and as directed. \nNote:- (a) No price adjustment shall be applicable if excess quantity of binder content is used / approved in the execution of work under this item. \n(b) Cement shall be used as filler as per job mix formula.\n(c) The marshall stability shall be a minimum of 1400 kg. \n(d) DAC shall be as per MORTH specifications as detailed in particular specifications. | 8278.09 | 10 SQM | |
| 3 | 3 | M & L for Preparing old bituminous surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface compressed air through mechanical means to remove all loose dirt etc, and providing Premix Dense Asphaltic Concrete (DAC) with grading 2 of IRC average 75 mm thick (consolidated thickness) in layers as directed using bitumen of grade PMB-40 with 5.6% minimum binder content (Marshal stability 1400 Kg) mixed by weight of total mix using hot mix plant spread, rolled and consolidated to required gradient and camber complete using necessary mechanical sensor paver and tandem vibratory roller of capacity exceeding 8 tonne but not exceeding 12 tonne capacity over tack coat of Paving Bitumen VG-10 @ 2kg/10 SqM complete all as specified and as directed. Note:- (a) No price adjustment shall be applicable if excess quantity of binder content is used / approved in the execution of work under this item. (b) Cement shall be used as filler as per job mix formula. (c) The marshall stability shall be a minimum of 1400 kg and minimum bitumen content 5.6% .(d) DAC shall be as per MORTH specifications as detailed in particular specifications. | 3782.1 | 10 SQM | |
| 4 | 4 | Demolition of unreinforced cement concrete in any position not other wise specifically provided for (PQC as in dispersals and Taxi Tracks) complete all as specified and directed. | 836.02 | CuM | |
| 5 | 5 | Removal of demolished PQC obtained from item no 4 above, to outside MD land at a distance exceeding 1.5 km but not exceeding 5 km at any place not objected by the civil authorities. (Note: Contractor has to find / locate the place where disposal of demolished PQC to be carried out in consulation with the local authorities prior to quoting. Nothing extra will be payable for any increase of distance) | 836.02 | CuM | |
| 6 | 6 | Excavation over areas not exceeding 1.5 mtr deep and getting out in hard / dense soil . | 1313.74 | CuM | |
| 7 | 7 | M&L for 300 mm thick granular sub base of grading all as specified, GSB V as per Morth Table 400-I over compacted subgrade spread rolled and consolidated to gradient and camber required by grader and rolled by vibratory roller to achieve required densiy in two layers of 150 mm each. | 238.86 | 10 SqM | |
| 8 | 8 | M&L for wet mix macadam (WMM) 150 mm thick (compacted thickness) in two layers 75 mm each with granite stone coarse aggregate of specified grade spread using mechnical paver as specified rolled and consolidated using 8 to 10 tonne capacity vibratory roller to required gradient and camber all as specified and directed. | 358.29 | CuM | |
| 9 | 9 | M&L for 100 mm compacted thickness dry lean concrete (DLC) with 7 days compressive strength 10 mpa by paver rolling as specified and directed.The minimum cement content shall be 180kg/cum. | 238.86 | CuM | |
| 10 | 10 | M&L for 10 mm thick (compacted) sand filling under floor/foundation and consolidation complete all as specified and directed. | 23.89 | CuM | |
| 11 | 11 | Supply & lay one layer polythene film transparent 400 micron HDPE sheet. Note -Nothing will be paid extra for overlapping of sheet.\n | 2388.62 | Sqm | |
| 12 | 12 | M & L for Cement Concrete work in pavement /Hard standing of flexural strength 45 Kg / Per Sq cm in field using minimum cement content 400 Kg per Cum as design mix , 350mm thickness of concrete using non circular synthetic fibre 0.25% by weight of cement, including necessary formwork, finishing surface of concrete pavement by texturing complete.\nNote: Nothing addl to be paid for extra cement / admixture or synthetic fibre. | 836.02 | CuM | |
| 13 | 13 | Forming expansion joint 350 mm deep x 25 mm wide with back up rod of 30 mm and filled with polyeurothene based sealing compound including 10 years guarantee all as shown on drawing and specified. | 18.17 | 10 RM | |
| 14 | 14 | Forming Construction joint 350 mm deep x 10 mm wide with back up rod of 12 mm and filled with polyeurothene based sealing compound including 10 years guarantee all as shown on drawing and specified. | 65.72 | 10 RM | |
| 15 | 15 | Forming Contraction (Dummy) 1/3 of depth of slab, 8 mm wide, with backup rod of 10 mm and filled with polyeurothene based sealing compound including 10 years guarantee all as shown on drawing and specified. | 49.21 | 10 RM | |
| 16 | 16 | M & L for preparation of new black top or concrete surface of runways and mechanically painting to line, dashes, arrows, letters etc and the like exc 10 cm wide to the shape and pattern as per instructions with two coats of water based paint 1st quality white, golden yellow and black etc complete all as specified and directed. | 7700 | SqM | |
| 17 | 17 | M&L for preparation of new black top or concrete surface of runways and mechanically painting to line, dashes, arrows, letters etc and the like not exc 10cm wide to the shape and pattern as per instructions with two coats of 1st quality water based paint on runway/taxi track etc complete all as specified and directed | 198.3 | 10 RM | |
| 18 | 18 | Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil | 55440 | CuM | |
| 19 | 19 | Rolling and consolidating formation surfaces in cutting using power roller exc 8 Tonnes but n.exc 12 Tonnes or vibratory rollers | 10080 | 10 SqM | |
| 20 | 20 | M&L Forming embankments using moorrum brought from outside MD Land including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling with 8 to 12 tone power vibrant roller to achieve required level / gradient and finishing to required size, shape, etc., n exc. 1.5 m high from base. | 60480 | CuM | |
| 21 | 21 | Removing excavated material (Soils) to outside MD land at a distance exceeding 1.5 km but not exceeding 5 km at any place not objected by the Civil Authorities. (Note : Contractor has to find/locate the place where disposal of excavated soils to be carried in consultation with the local authorities prior to quoting. Nothing extra will be payable for any increase in distance. | 56753.7 | CuM | |
| 22 | 22 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles | 3268.96 | CuM | |
| 23 | 23 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) | 264.12 | CuM | |
| 24 | 24 | Removing unserviceable stone pitching/cement mortar/, PCC beds etc to outside MD land at a distance exceeding 1.5 km but not exceeding 5 km at any place not objected by the civil authorities. (Note: Contractor has to find/locate the place where disposal of demolished materials to be carried in consultation with the local authorities prior to quoting. Nothing extra will be payable for any increase in distance). | 569.4 | CuM | |
| 25 | 25 | M&L for Boulder pitching hand packed tightly and grouted with cement and sand mortar 1:6 Except Stones. | 1657.59 | CuM | |
| 26 | 26 | M&L for Cement concrete type D-2 (1:4:8) using 40 mm graded broken stone aggregates as in foundations, filling and mass concrete. | 459.85 | CuM | |
| 27 | 27 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 using old size bricks | 114.74 | CuM | |
| 28 | 28 | M&L for Providing cement concrete 1:2:4 type-B-1 using 20 mm graded broken granite/ trap/ basalt stone aggregate as in copings including use of necessary form work | 19.65 | CuM | |
| 29 | 29 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement | 393.07 | SqM | |
| 30 | 30 | M&L for preparing newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant priming paint | 393.07 | SqM | |
| 31 | 31 | Returning, filling in and well ramming in layers n. exceeding 25 cm, including spreading levelling, using moorum/red bajri brought from outside MD Land | 385.59 | CuM | |
| 32 | 32 | M & L for Pre-cast RCC drains with perforated cover slabs of size 600x600 (T-25) of grade M40 concrete from reputed manufacturer as per sketch attached all as specified and directed. Make:Fuji Silvertech / Alcock/ Teemage | 835 | RM | |
| 33 | 33 | M & L for Pre-cast RCC drains without cover slabs of size 600x600 (T-25) of grade M40 concrete from reputed manufacturer as per sketch attached all as specified and directed. Make:Fuji Silvertech / Alcock/ Teemage | 835 | RM | |
| 34 | 34 | M & L for Pre-cast RCC drains with perforated cover slabs of size 750x750 (T-25) of grade M40 concrete from reputed manufacturer as per sketch attached all as specified and directed. Make:Fuji Silvertech / Alcock/ Teemage | 300 | RM | |
| 35 | 35 | M & L for Pre-cast RCC drains without cover slabs of size 750x750 (T-25) of grade M40 concrete from reputed manufacturer as per sketch attached all as specified and directed. Make:Fuji Silvertech / Alcock/ Teemage | 200 | RM | |
| 36 | 36 | M & L for Pre-cast RCC drains with perforated cover slabs of size 900x900 (T-25) of grade M40 concrete from reputed manufacturer as per sketch attached all as specified and directed. Make:Fuji Silvertech / Alcock/ Teemage | 600 | RM | |
| 37 | 37 | M & L for Pre-cast RCC drains without cover slabs of size 900x900 (T-25) of grade M40 concrete from reputed manufacturer as per sketch attached all as specified and directed. Make:Fuji Silvertech / Alcock/ Teemage | 400 | RM | |
| 38 | 38 | Taking down existing old unserviceable cables and supply, laying in trenches/ ducts/ walls/pipes, testing and commissioning new runway light cable, 5 kV grade stranded copper conductor XLPE insulated PVC sheathed cables suitable for airfield lighting of size 1 core, 6 sqmm as per IS:1554 Part II including cleaning/ clearing of existing cable duct crossing the runway and providing the following all as specified and directed:-\n(i) Cable route indicators of standard specifications at every 10m throughout the runway.\n(ii) Brick pit 600mm x 600mm x 900mm for cable inspection at every 150m on both sides of the runway. \nNote :- Cleaning/ clearing of existing cable ducts shall be deemed to be included in quoted rates.\nMake of cable :- RALLISON/ EUPEN/ POLYCAB/ HAVELLS/ANKUR/KEI/LAPP | 15400 | RM | |
| 39 | 39 | Taking down existing old unserviceable cables and supply, laying in trenches/ ducts/ walls through pipes, testing and commissioning new runway light cable, stranded copper conductor PVC insulated, armoured, PVC sheathed cables suitable for airfield lighting of size 100 core 2.5sqmm as per IS:1554 Part II.( CCR room to ATC)\n Make - RALLISON/ EUPEN/ POLYCAB/ HAVELLS/ANKUR/KEI/LAPP | 200 | RM | |
| 40 | 40 | Taking down old unserviceable light fittings complete and supply, Installation, testing & Commissioning new bi-directional elevated type high intensity runway edge light fitting suitable for and including 200W 6.6A halogen lamp complete with all accessories including lamp, lens, filters (colours as required), secondary lead etc. base plate mounted on breakable coupling all as specified (Runway Edge Light).\nMake - AMA /ADB Safegate/ Hughey& Philips/ EATON\nTHORN/ HONEYWELL/ ATG/ OCEM AIRFIELD TECHNOLOGY\nNote - Colour of the light / Filter as per requirement to be approved by user. | 53 | Each | |
| 41 | 41 | Supply, Installation, testing & Commissioning new bi-directional inset type high intensity runway centreline light fitting suitable for and including 45W/48W 6.6A halogen lamp complete with all accessories including lamp, lens, filters (Red and White colour filters), secondary lead base plate etc all as specified. (Runway centre line light).\nMake -AMA /ADB Safegate/ Hughey& Philips/ EATON\nTHORN/ HONEYWELL/ ATG/ OCEM AIRFIELD TECHNOLOGY\n | 59 | Each | |
| 42 | 42 | Taking down old unserviceable light fittings complete and supply, Installation, testing & Commissioning new bi-directional elevated type high intensity runway end threshold light fitting suitable for and including 200W 6.6A halogen lamp complete with all accessories including lamp, lens, filters (Red and Green colour or as specified by user), secondary lead etc. base plate mounted on breakable coupling all as specified. (Threshold lights).\nMake -AMA /ADB Safegate/ Hughey& Philips/ EATON\nTHORN/ HONEYWELL/ ATG/ OCEM AIRFIELD TECHNOLOGY\n | 10 | Each | |
| 43 | 43 | Supply, Installation, testing & Commissioning new uni-directional elevated type high intensity runway wing bar edge light fitting suitable for and including 200W 6.6A halogen lamp complete with all accessories including lamp, lens, filters (colours as required), secondary lead etc. base plate mounted on breakable coupling all as specified. (Wing Bar/ Cross Bar lights). \nMake - AMA /ADB Safegate/ Hughey& Philips/ EATON\nTHORN/ HONEYWELL/ ATG/ OCEM AIRFIELD TECHNOLOGY\n | 10 | Each | |
| 44 | 44 | Taking down old unserviceable light fittings complete and supply, Installation, testing & Commissioning new omni-directional elevated type high intensity runway edge light fitting suitable for and including 200W 6.6A halogen lamp complete with all accessories including lamp, lens, filters (colours as required), secondary lead etc. base plate mounted on breakable coupling all as specified. (For Middle Marker).\nMake - AMA /ADB Safegate/ Hughey& Philips/ EATON\nTHORN/ HONEYWELL/ ATG/ OCEM AIRFIELD TECHNOLOGY\n | 10 | Each | |
| 45 | 45 | Taking down old unserviceable light fittings complete and supply,Installation, testing & Commissioning new medium intensity elevated type omni directional taxiway edge light fitting suitable for and including 45 W 6.6A lamp complete with all accessories including blue lens, lamp, filters, secondary lead etc.base plate mounted on breakable coupling all as specified. (Taxi way edge lights).\nMake - AMA /ADB Safegate/ Hughey& Philips/ EATON\nTHORN/ HONEYWELL/ ATG/ OCEM AIRFIELD TECHNOLOGY\n | 46 | Each | |
| 46 | 46 | Taking down old unserviceable light fittings complete and supply, Installation, testing & Commissioning new medium intensity omni directional taxiway edge inset type light fitting suitable for and including 45W 6.6A lamp complete with all accessories including blue lens, lamp, filters, secondary lead base plate etc including making good the surface similar to the original surface all as specified and directed. (taxiway inset type light).\nMake - AMA /ADB Safegate/ Hughey& Philips/ EATON\nTHORN/ HONEYWELL/ ATG/ OCEM AIRFIELD TECHNOLOGY\n | 22 | Each | |
| 47 | 47 | Taking down old unserviceable light fittings complete and supply, Installation, testing & Commissioning new medium intensity Bi-directional taxiway centreline (Green/Green) inset type light fitting suitable for and including 45W/48W 6.6 A lamp complete with all accessories including, lamp, filters, secondary lead etc.base plate mounted on breakable coupling all as specified. (Taxiway Centre line lights).\nMake - AMA /ADB Safegate/ Hughey& Philips/ EATON\nTHORN/ HONEYWELL/ ATG/ OCEM AIRFIELD TECHNOLOGY\n | 12 | Each | |
| 48 | 48 | Taking down old unserviceable light fittings complete and supply, Installation, testing & Commissioning new Precision Approach Path Indicator (PAPI) light fitting 200 W in full compliance with AC 150/5345 28D complete with and including lamps of 200W(set of four fittings, each fitting having three lights each of 200W)ground calibration kit suitable length for secondary kit and isolation transformer with all accessories, excavation, earthwork & PCC. (PAPI lights).\nMake -AMA /ADB Safegate/ Hughey& Philips/ EATON\nTHORN/ HONEYWELL/ ATG/ OCEM AIRFIELD TECHNOLOGY\n | 2 | Set | |
| 49 | 49 | Taking down old unserviceable transformer and accesories and supply, Installation, testing & Commissioning new isolating transformer 5KV grade 50 Hz series type moulded with neoprene type rubber with primary and secondary connectors as specified for run way light 200 W/6.6/6.6A, all as specified and directed.\nMake - AMA/ ADB Safegate/ Hughey & Philips/ EATON/\nTHORN/ HONEYWELL /ATG/ OCEM AIRFIELD\nTECHNOLOGYI BILDAL\n | 83 | Each | |
| 50 | 50 | Taking down old unserviceable transformer and accesories and supply, Installation, testing & Commissioning new isolating transformer 5KV grade 50 Hz series type moulded with neoprene type rubber with primary and secondary connectors lead as specified for taxy way light 45W 6.6/6.6 A. all as specified and directed.\nMake -AMA/ ADB Safegate/ Hughey & Philips/ EATON/\nTHORN/ HONEYWELL /ATG/ OCEM AIRFIELD\nTECHNOLOGYI BILDAL\n | 139 | Each | |
| 51 | 51 | Supply, Installation, testing & Commissioning new connector kit 5KV grade plug and receptacle of type 1 class \"B\" connector for suitable field attachment of 5KV grade PVC insulated, PVC sheathed, single core, copper conductor, unarmoured cable of size 6 sqmm.\nMake -AMA/ ADB Safegate/ Hughey & Philips/ EATON/\nTHORN/ HONEYWELL /ATG/ OCEM AIRFIELD\nTECHNOLOGYI BILDAL\n | 246 | Each | |
| 52 | 52 | Taking down old unserviceable connector kits and supply and fix new secondary connector kit, moulded type suitable for 5 KV grade 6sqmm single core cable, complete all as specified and directed\nMake -AMA/ ADB Safegate/ BILDAL | 83 | Each | |
| 53 | 53 | Taking down old unserviceable transformer housing box and supply, Installation, testing & Commissioning new CI transformer housing box including excavation, earthwork, PCC etc. complete all as specified and as shown on drawing.\nMake -AMA / ADB Safegate / YPR | 246 | Each | |
| 54 | 54 | Taking down old unserviceable wires and provision of Material and Labour for galvanised iron wire 6SWG/8 mm as earth continuity conductor or main earth lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed. | 15400 | RM | |
| 55 | 55 | Taking down old unserviceable remote control desk and supply,Installation, testing and commission new remote control desk cum display unit at ATC tower suitable for remote operation of constant current regulators and all runway light system from ATC tower and comprising of following inter-connections and items with terminal blocks etc as specified including following components.\nMake - AMA/ ADB Safegate/ Hughey& Philips EATON\nTHORN/ HONEYWELL/ ATG/ OCEM AIRFIELD TECHNOLOGY/ BILDAL/ NASU SYSTEMS\n (a) UPS backup (minimum 30 minutes) at ATC & CCR room (b) One touch screen with accessories (c) One monitor with connected accessories (d) Two vault processor one for master and one for redundancy (e) Comptability for two OFC cable one for master and one for redundancy | 1 | Each Job | |
| 56 | 56 | Taking down old unserviceable ILDI light and control wiring with holders and lamps after disconnecting the electric connection and supply, fix and fabricate new ILDI assembly having \"H\" shape with new galvanised iron sheet 20 SWG of total surface area 5.5 sqm bent to 'H' shape in rectangular box type including renewal of copper conductor cable single core FRLS 1100 volts grade 2.5 sqmm for giving connection to 33 Nos LED lamps in two circuit system and porcelain lamp holders including LED lamp and holder base support with rubber gasket 33 Nos. The holders & lamps shall be fixed on upper surface of GI sheet and control wiring shall be laid inside rectangular box. The ILDI assembly shall be mounted on GI pipe supports 01 mtr above ground level with suitable MS frame complete all as specified and directed. Make AMA/ADB Safegate/ Hughey & Philips/ Thorn Should conform to ICAO Annex 14, Vol 1 | 1 | EACH JOB | |
| 57 | 57 | Taking down old unserviceable wind indicator assembly and control wiring with holders and lamps after disconnecting the electric connection and supply, fix and fabricate new illuminated wind indicator (WDI) with new galvanised iron pipe and copper conductor cable single core FRLS 1100 volts grade 2.5 sqmm including LED aviation obstruction light. The holders & lamps shall be fixed on upper surface of wind cone and control wiring shall be laid inside pipe. The wind cone assembly shall be mounted on MS base plate complete all as specified and directed. Make AMA/ ADB Safegate/ Hughey & Philips/ EATON/\nTHORN/ HONEYWELL /ATGI OCEM AIRFIELD\nTECHNOLOGY \nShould conform to ICAO Annex 14, Vol 1 | 1 | EACH JOB | |
| 58 | 58 | Taking down old unserviceable rotating beacon assembly and control wiring with holders and lamps after disconnecting the electric connection and supply, fix and fabricate new rotating beacon assembly with new galvanised iron pipe and copper conductor cable single core FRLS 1100 volts grade 4.0 sqmm including four lamp of 1000 W each (white and green colour) . The holders & lamps shall be fixed on upper surface of beacon and control wiring shall be laid inside pipe. The Beacon assembly shall be mounted on MS base plate complete all as specified and directed. Make -AMA/ ADB Safegate/ Hughey & Philips/ EATON/\nTHORN/ HONEYWELL /ATG/ OCEM AIRFIELD\nTECHNOLOGY\n | 1 | EACH JOB | |
| 59 | 59 | Taking down old unserviceable night wind cone and control wiring with holders and lamps after disconnecting the electric connection and supply and fix new Night Wind Cone complete with all accessories all as specified and directed. \nMake-AMA/ ADB Safegate/ Hughey & Philips/ EATON/\nTHORN/ HONEYWELL /ATG/ OCEM AIRFIELD\nTECHNOLOGY\n | 1 | EACH JOB | |
| 60 | 60 | Taking down old unserviceable DTGMs and supply and installation new DTGMs (12 Nos) with standard ICAO specifications at various places throughout the runway, including fixing the DTGMs with PCC and/ or other adequate arrangements. Digits/ markings (as specified and directed) on the DTGMs should be made with ICAO specified reflective tape so as to be visible at night using ambient lighting.\nMake of DTGM :-AMA/ ADB Safegate/Hughey & Philips/ EATON\nTHORN/ HONEYWELL/ ATG/ OCEM AIRFIELD TECHNOLOGY! BILDAL/ NASU SYSTEMS\nNote :- PCC and other adequate arrangements for rigid fixing of the DTGMs, reflective tape .etc. shall be deemed to be included in the quoted rates.\n | 1 | EACH JOB | |
| 61 | 61 | Supply, laying in trenches through pipe, testing and commissioning new electric cable, multistranded copper conductor 1100 volts grade, PVC insulated, PVC sheathed cables, unarmoured of size 2 core 2.5sqmm as per IS:1554 Part II. \nMake - RALLISON/ EUPEN/ POLYCAB/ HAVELLS/ANKUR/KEI/LAPP | 1929 | RM | |
| 62 | 62 | Taking down old unserviceable pipes/ cable covers and connected items and supply and lay new high density polyethylene DWC pipes of 40mm OD/32mm ID, 6 kgf/sqcm including all fittings (bends, Tees, Elbows, sockets, etc) as required on site, complete all as specified and directed. (For runway light cable protection.)\nMake - Finolex/Reliance/Supreme/Noble Note:Excavation, return filling and removal of any type of soil/ strata shall be measured and paid separately under respective items of BOQ. | 9960 | RM | |
| 63 | 63 | M&L for cutting of bituminous road/Runway/Hardstanding upto 450mm depth by using mechanical method carefully without damaging the surrounding area/bituminous area suitable for taxiway/runway centre line light fitting and insertion of centre line light fitting, matching the existing runway using Dobefil and hardener to fill gap between light and road layers as per manufacturers specifications and PCC bedding complete all as specified and directed. (for runway edge light, runway centre line lights, taxiway cente line lights, taxiway edge inset lights, runway threshold lights) | 160 | Each job | |
| 64 | 64 | Excavation in trenches/ existing cable ducts .etc. in any type of soil/ strata and soil conditions not exceeding 1.5m wide and not exc 1.5m in depth for laying of cables, protection pipes and foundations etc and getting it out in any type of soil complete all as specified and directed. | 2151 | Cum | |
| 65 | 65 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and directed. | 2140 | Cum | |
| 66 | 66 | Removing excavated material not exc 50 m distance and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed. | 19 | Cum | |
| 67 | 67 | Taking down old unserviceable earthing and M & L for Earthing complete with GI earth plate electrode 600 mm x 600mm x 6.3 mm thick buried directly in ground vertically to a depth not less than 2.25 Mtr below ground level with the top edge of earth plate at depth not less than 1.5 Mtr below ground level connected to galvanised iron strip 32x6 mm by means of bolts, washers ,watering pipe 20mm dia, medium grade GI pipe, with welded funnel and wire mesh and 40mm dia medium grade GI pipe with fitting as protection pipe for strip from plate electrode to test point / plant / machineries etc. including concrete pit in PCC (1:3:6) type C-I having outer dimension 60cmx60cmx60cm and internal dimension 30cmx30cmx30cm, precast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia deformed bares @15 cm centre to centre both direction and 10 mm dia MS handle of suitable size charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as show in electrical plate No 3 of MES Schedule Part I and testing complete all as specified and as directed. | 14 | Each Job | |
| 68 | 68 | Taking down old unserviceable earthing and M & L for Earthing complete with GI earth plate electrode 600 mm x 600mm x 6.3 mm thick buried directly in ground vertically to a depth not less than 2.25 Mtr below ground level with the top edge of earth plate at depth not less than 1.5 Mtr below ground level connected to galvanised earth lead wire 4.0 mm by means of bolts, washers ,watering pipe 20mm dia, medium grade GI pipe, with welded funnel and wire mesh and 15mm dia medium grade GI pipe with fitting as protection pipe for galvanised earth lead wire from plate electrode to test point / plant / machineries etc. including concrete pit in PCC (1:3:6) type C-I having outer dimension 60cmx60cmx60cm and internal dimension 30cmx30cmx30cm, precast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia deformed bares @15 cm centre to centre both direction and 10 mm dia MS handle of suitable size charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as show in electrical plate No 3 of MES Schedule Part I and testing complete all as specified and as directed. | 25 | Each Job | |
| 69 | 69 | M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machining with and including HDPE pipe of 25mm dia suitable for 0.4 MPa working pressure. (For runway centre line light, runway edge light, taxiway cente line light, taxiway edge inset light) MAKES:FINOLEX/ RELIANCE/SUPREME/ NOBLE | 3380 | RM | |
| 70 | 70 | Taking down old unserviceable constant current regulator panels and connected accessories including control wiring after disconnecting the electric connection and supply, install, test and commisssion new constant current regulator of runway light circuit-I & II, Taxiway light circuit, PAPI light circuit I and II at supply voltage 230v, 50 Hz single phase and control voltage 110v with all its accessories and connected items comprising of following inter-connection extra with terminal block etc as specified including following components.\nMake-AMA / ADB Safegate/Hughey & Philips/ Nasu systems.\n(a) CCR for runway light circuit- I, 230V, 50 Hz, 10 KW, single phase and control voltage 110v-01 No. (b) CCR for runway light circuit- II, 230V, 50 Hz, 10 KW, single phase and control voltage 110v-01 No. (c) CCR for taxiway light circuit, 230V, 50 Hz, 10 KW, single phase and control voltage 110v-01 No.\n(d) CCR for PAPI circuit - I light , 230V, 50 Hz, 4 KW, single phase and control voltage 110v-01 No. (e) CCR for PAPI circuit - II light ,230V, 50 Hz, 4 KW, single phase and control voltage 110v-01 No. (f)Main power control by MCCB 100A, 4 Pole, 25 kA - 1 No (g) ON/OFF Toggle switch 5 position brightness control switch DC power pack for indicating lamps, mimic diagram, control MCB, terminal block, selector switch for following systems :- (i) Runway circuits : Two Nos with status indication of each circuit in the mimc diagram shall show runway edges, ends, threshold and turning pad with colour LED (Green for threshold, blue for turning pad, red for end lights and separate yellow and amber colours for circuit one and circuit two)\n (ii) PAPI : Two Nos side selection switch and status indication in the mimic diagram shall show both the end side PAPI with red LEDs. (iii) Taxi way : 01 No side selection switch and status indication in the mimic diagram shall show the taxiway and apron edges with blue colour LED.(iv) Spare : 02 Nos ON/OFF toggle switch\n(h) Mimic display system:1 set for complete circuit. (j) Wind cone : - 1 No, ON/OFF switch and status indication in the mimic display.\n(k) Landing 'H' : 1 No, ON/OFF switch with status indication with side selection switch and status indication in mimic display.\n(l) Aerodrome beacon : 01 No ON/OFF switch and status indication in mimic display.\n(m) Spare : 02 No, ON/OFF toggle switch \n | 1 | Each Job |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail