Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #26420545

Repair Maintenance Of Lt Oht Lines Poles Cable And Connected Works Including Street Light And Upkeep Of Em Installations And Premonsoon Maintenance For Em Services Repair Maintenance Of Em Services At Hansa Vihar Nts South And North Side Of Runway Un

Issued by Statutory Bodies & Commissions/Committees · CWE NAVY VASCO, Goa
Tender Value
Ref. Documents
Estimated cost
Bid Submission
18 Jan 2021
0 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
CWE NAVY VASCO → Goa
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair Maintenance Of Lt Oht Lines Poles Cable And Connected Works Including Street Light And Upkeep Of Em Installations And Premonsoon Maintenance For Em Services Repair Maintenance Of Em Services At Hansa Vihar Nts South And North Side Of Runway Un

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 11-Jan-2021 TENDER CORRI Other 18-Jan-2021

BOQ

NAME OF WORK:REPAIR/MAINTENANCE OF LT OHT LINES,POLES,CABLE AND CONNECTED WORKS INCLUDING STREET LIGHT AND UPKEEP OF E/M INSTALLATIONS AND PREMONSOON MAINTENANCE FOR E/M SERVICES,REPAIR/MAINTENANCE OF E/M SERVICES AT HANSA VIHAR,NTS,SOUTH AND NORTH SIDE OF RUNWAY UNDER GE (NW) VASCO
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Excavation in trenches 1.5 m wide and not exceeding 1.5 m deep in hard/dense soil getting out and levelling of bottom surface to required level for laying UG cable / erection of poles complete all as specified and as directed.20Cum
22Excavation in trenches 1.5 m wide and not exceeding 1.5 m deep in soft/disintegrated rock getting out and levelling of bottom surface to required level complete all as specified and as directed.10Cum
33All as per item No. 2 here in before but exceeding 1.5 m in depth and 1.5 m in width in soft/disintegrated rock for erection of poles complete all as specified and as directed.1Cum
44Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wall for laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and as directed.2Cum
55Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick all as specified and as directed.25Cum
66Removing excavated material of soils from site to a distance not exceeding 50 m away and depositing where directed not exceeding 1.5 m from the starting point complete all as specified and s directed.5Cum
77Supplying & Laying in trenches Clear Sand/m- Sand for cushioning under ground cable 8 cm below and 15 cm above complete in level complete all as specified and as directed. Note: Punned thickness shall be measured and paid.65Cum
88Supplying & Laying precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm in trenches to protect under ground cable complete all as specified and as directed.300Each
99Taking down old unserviceable LT UG cable from any description (trenches, walls, ceilings etc) from various locations, laying only under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 120 Sq mm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098( Part-1) along with suitable size aluminium cable lugs, gland if required and jointed in any description removal of old unserviceable cable all as specified and as directed.100RM
1010All as per item No 9 here in before but of size 3 1/2 core 150 sqmm all as specified and as directed.100RM
1111All as per item No 9 here in before but of size 3 1/2 core 240 sqmm all as specified and as directed.100RM
1212All as per item No 9 here in before but of size 3 1/2 core 95 sqmm all as specified and as directed.\nNotes item No 09 to 12 :- \n (a) Excavation, Concrete cable protection cover, pipe, PCC work for road crossing/hard standing and Sand for cushioning will be measured and paid separately.\n(b) Cost of glands, aluminium cable lugs (eye lid/ barrel/ bottle neck type/ ring type or any shape) new nut, bolt and washers of required size/description are deemed to include in this rate. (c) LT UG XLPE cable shall be issued under Sch B free for laying only.100RM
1313S & F in repairs LT heat shrinkable Straight through cable Jointing kit, complete with jointing material and accessories suitable for 2 core XLPE armoured aluminium conductor cable of size 10 to 16 sq mm complete all as specified and as directed.5Each
1414All as per item No 13 here in before but of size 4 core 16 to 25 sqmm all as specified and as directed.5Each
1515All as per item No 13 here in before but of size 3.5 core 35 to 50 sqmm all as specified and as directed.4Each
1616All as per item No 13 here in before but of size 3.5 core 70 to 95 sqmm all as specified and as directed.4Each
1717All as per item No 13 here in before but of size 3.5 core 120 to 150 sqmm all as specified and as directed.3Each
1818M&L for fault finding of LT cables of size 35 to 150 sq mm X 3.5 core and any length with fault detective machine by thumbing method and suitable voltage and all as per manufactures instructions including providing straight through joint and additional cable of same existing size suitable to site requirement complete all as specified and as directed8Each Job
1919S&F in repair changeover switches on load changeover switches 4 pole 630 Amps in sheet steel enclosure with enclosure, including necessary spreaders/cable lugs/gland/nut, bolt and washers if required complete all as specified and as directed.1Each
2020All as per item No 19 here in before but of capacity 400 A 4 pole 415 Volts all as specified and as directed.1Each
2121All as per item No 19 here in before but of capacity 250 A 4 pole 415 Volts all as specified and as directed.1Each
2222All as per item No 19 here in before but of capacity 200 A 4 pole 415 Volts all as specified and as directed.1Each
2323M & L for PCC type D-2, 1:4:8 using 40 mm graded stone aggregate including use and waste of form work of concrete for any description including preparation work necessary complete all as specified and as directed.10Cum
2424M & L for PCC type C-1,1:3:6 using 20 mm graded stone aggregate including use and waste of form work / mass concrete for coping of poles/using at any description complete all as specified and as directed.6Cum
2525M&L for brick work with subclass 'B' bricks old size straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 for filling the space created due to taking down old pattern DB/Meter box all as specified and as directed.4Cum
2626M&L for rendering 10 mm thick on brick or concrete surfaces in cement mortar 1:4 finished surfaces even and smooth without using extra cement complete all as specified and as directed.30Sqm
2727M&L for priming plastered and other surfaces with alkali resistant priming paint complete all as specified and as directed.30Sqm
2828S&F laying in trenches/on wall/poles/structures as in repairs GI tubing light grade of size 100 mm dia for road crossing/for cable protection/fixing of pygmy lights etc of the following sizes including necessary provision for cable entry if required in pygmy lights pole, fixing MS nut, bolt & washers/MS clamps complete as required complete all as specified and as directed12RM
2929All as per item No 28 here in before but of size 80 mm dia all as specified and as directed60RM
3030All as per item No 28 here in before but of size 50 mm dia all as specified and as directed50RM
3131All as per item No 28 here in before but of size 40 mm dia all as specified and as directed50RM
3232Taking out the old LT UG serviceable cable of 3.5 core 35 to 300 Sq mm from trenches/ floors/ walls and relaying/diversion/jointing the same in the existing/new trenches/new location as directed and connecting all as specified and as directed120RM
3333S&F in repairs galvanised Iron cross arms channel, bracing, support, clamps , fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete including taking down/dismantling the old items complete in any sub station /installations structure complete all as specified and as directed4Qtl
3434S & F in repairs Pin type porcelain vitreous, brown of white insulator to suit 1100 Volt working pressure of size 100 mm height, 65mm dia, including one galvanised mild steel spindle, two galvanised iron washer and one GI nut complete all as specified and as directed.10Each
3535S & F in repairs Shackle type Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, of height 100 mm and dia 115 mm having working pressure 1100 volts grade complete all as specified and as directed.5Each
3636Dismantling of existing old unserviceable ACSR of any size from any description, material and labour for providing new ACSR conductor all as specified and as directed including stringing through existing RCC poles, fixing in insulators, jumpers with polythene pipe, aluminium binding wire etc complete of different sizes complete all as specified and as directed. Note : Rates for new AAC/Aluminium binding wire for binding purpose shall deemed to be included in the quoted rate.0.25Qtl
3737Dismantling carefully and Re-fixing with re-string of serviceable ACSR conductor of any size with new aluminium binding wire of suitable size including taking down the old one for replacement of pole / cross arms etc carefully complete all as specified and as directed \nNote : Rates for new AAC/Aluminium binding wire for binding purpose shall deemed to be included in the quoted rate.0.5Qtl
3838S & F in repairs air termination, single pointed, copper rod 12 mm dia and 300 mm long along with base including dismantling the old complete all as specified and as directed8Each
3939S & F in repairs air termination, single pointed aluminium rod 12 mm dia and 300 mm long with base including dismantling the old complete all as specified and as directed15Each
4040S & F in repairs test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw in any location including dismantling old one complete all as specified and as directed70Each
4141S & F in repairs aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors / earth continuity and down conductors above / buried in ground / run on floor/fixed on wall including taking out old conductor complete all as specified and as directed80RM
4242All as per item No 41 here in before but copper strip 20 x 3.15 mm all as specified and as directed.100RM
4343All as per item No 41 here in before but galvanised iron strip 32 x 6 mm complete all as specified and as directed50RM
4444M & L for new RCC poles of 9 m long having 102 mm x 152 mm at top and 102 mm x 289 mm at bottom, class 11. complete and provides with two coats of ACC exterior Emulsion paint over a coat of cement primer of surface including 12 cm black paint around the pole numbers/letters in white columns complete all as specified and as directed\nNote : Excavation,Earth work and PCC shall be measured and paid separately under relevant time of this schedule6Each
4545M & L for earthing complete with GI earth plate, electrode,600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32 x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 3 of SSR Part-I and connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia upto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber complete all as specified and as directed by Engr-in-charge including demolishing existing earth pit and taking out old materials.8Each\n
4646M & L for earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to copper strip size 20 x 3 mm thick by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 3 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 m from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed10Each
4747M & L for earthing complete with galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 3 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 m from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed5Each\n
4848Carrying out comprehensive maintenance for 5 KVA capacity 3 phase 440 volts UPS system along with battery bank, invertor and connected accessories complete as per the manufactures instructions and keeping the equipment serviceable condition and complete all as specified and as directed Notes : \n(a) New batteries will be measured and paid separetely, (b) Rates for repair /replacement for spares/parts such as PCBs, Relays, fuses, connecting cables, transformers etc which in case damaged during the contract period shall be included in the quoted rates)6Per month
4949S & F in repairs HT/LT cable route indicator standard size made out of MS disc size 4\" size with MS Flat iron fixed with two nos of nut, bolt and washers and provision of PCC type D-2 , 1 : 4 : 8 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base buried under the ground including necessary earth work complete all as specified and as directed95Each Job
5050Supply and wrapping of HT insulation tape 25 mm width in 5 m roll complete all as specified and directed30Roll
5151Supply and wrapping of LT insulation tape 12 mm width in 5 m roll complete all as specified and directed150Roll
5252S & F in repairs lead acid battery 12 Volt 180 AH for fire detection system complete all as specified and directed4Each
5353S & F in repairs lead acid battery 12 Volt 90 AH for fire detection system complete all as specified and directed4Each
5454S & F in repairs connecting and commissioning sealed maint free battery 12 volts 42 AH all as specified and directed8Each
5555M & L for removing vegetation, grass, scrubs and bushes or any small tree branches growing in Sub station yard along with fencing, around the pole, under the HT / LT transmission lines, yards or any description by manually/mechanically and keep the sub station yard neat and clean complete all as specified and directed \nNote :- Unit rate quoted deemed to include to keep the installation neat and clean throughout the period of contract and each cleaning will be measured and paid.30000Sqm
5656M & L for cutting and trimming of tree branches of girth up to 150 mm dia and 3 m all around of any size obstructing lumination of street light/perimeter lights and touching LT/HT Over head line including removing trimmed tree branches complete all as specified and directed\nNote ; Each cut will be measured and paid600Per Job
5757M & L for testing of earthing value as per standard procedure for each pipe/plate/wire/any type of earthing by disconnecting the joint/lead and measuring the earth value by using suitable Tools and plants such as mugger, spikes and leads in presense of Engineer- In - Charge and submitting the value to standard format in duplicate including connecting back the leads by providing new GI nut, bolts and washers of same size complete all as specified and directed .\nNote : The rate inclusive of make good for any damages made during testing except the following200Each
5858M & L for cleaning the earth pit neatly by removing the vegetation/waste/dusts from the earth pit chamber by opening the chamber cover and marking of identification on the chamber cover by means of synthetic enamel paint complete all as specified and as directed200Each
5959S & F in repairs of Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment cut to required shape and size for cable duct or any other description complete all as specified and as directed1200Kgs
6060M & L in replacement of RCC earth pit chamber cover of 50 mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways and lifting hook complete all as specified and as directed40Each
6161M & L in replacement of CI earth pit chamber cover of 6 mm thick of existing size, including angle iron frame for mounting of chamber cover and lifting hook complete all as specified and as directed50Each
6262S & F in repairs aluminium cable lugs eye let (Ring)/bottle neck type for the following size of cable including cutting the existing burnt out/UNSV/damaged lugs from existing cable by taking out loop/looses cable from the position including cutting the damaged portion and preparation work and connecting to any descrption complete all as specified and as directed
6362.01(a) 16 Sqmm cable200Each
6462.02(b) 25 Sqmm cable200Each
6562.03(c) 35 Sqmm cable250Each
6662.04(d) 50 Sqmm cable150Each
6762.05(e) 70 Sqmm cable150Each
6862.06(f) 95 Sqmm cable120Each
6962.07(g) 120 Sqmm cable70Each
7062.08(h) 150 Sqmm cable50Each
7162.09(i) 185 Sqmm cable50Each
7262.1(k) 240 Sqmm cable30Each
7362.11(l) 300 Sqmm Cable20Each
7463Supply only LED driver with transformer suitable for 25 to 60 watts LED street/Flood/high bay light fitting of complete all as specified and as directed.30Each
7564All as per item No. 63 here in before but of capacity 70 to 90 watts LED fittings complete all as specified and as directed25Each
7665All as per item No. 63 here in before but of capacity 120 to 150 watts LED fittings complete all as specified and as directed20Each
7766All as per item No. 63 here in before but of capacity 200 to 240 watts LED fittings complete all as specified and as directed20Each
7867S&F in repairs Digital voltmeter with VSS -01 set of complete all as specified and as directed8Each
7968S&F in repairs Digital Ammeter with CTs & ASS-01 set of complete all as specified and as directed8Each
8069S&F in repairs LED phase indication lamps (RYB-01 Each set) of complete all as specified and as directed10Each
8170S & F in repairs integral LED aviation light comprising of aluminium housing with polycarbonate enclosure with necessary fixing arrangement such as GI pipe, fixing clamp, brackets, etc., complete all as specified and directed8Each
8271S&F in repairs LED flood light fitting 200 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED's and electronic driver, internally prewired including necessary fixing arrangement on PCC pole by providing MS angle iron bracket 50x50x6mm of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection complete all as specified and directed12Each
8372S&F in repairs LED flood light fitting 240 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED's and electronic driver, internally prewired including necessary fixing arrangement on PCC pole by providing MS angle iron bracket 50x50x6mm of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection complete all as specified and as directed10Each
8473S&F in repairs smart integrated solar street light 25 W with built in Mono Crystalline panel, Lithium Ferro Phospate (LiFeP04) battery, MPPt Charge Controller and PIR sensor with colour Temperature 6000-6500K, including necessary fixing arrangement on PCC pole/wall by providing with necessary nuts, bolts and washers etc and making cable connection complete all as specified and as directed10Each
8574Supply only street light bracket made out of GI tubing 32 mm dia, light grade bend to shape of approximate length 1.0 m long suitable for security/street light fittings with necessary MS clamps - 02 Nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers etc complete all as specified and as directed8Each
8675S & F in repairs Street light bracket made out of GI tubing 25 mm dia, light grade bend to shape of approximate length 1.0 m long suitable for security/street light/Pygmy light fittings with necessary fixing arrangements -with one coat of red oxide and two coats of synthetic enamel paint including nut, bolt, washers etc complete all as specified and as directed5Each
8776M & L for preparation of old cement coated surface, cleaning the surface of the RCC pole of total height 9 m/11 m, above the ground level including coping area (if provides) with 2 coats of ACC exterior Emulsion paint over a coat of cement primer after preparation of surface including 12 cm black paint around the pole numbers/letters in white columns complete all as specified and as directed300Job
8877S&F in repairs cable junction boxes IP 66 protected “halogen free and weather proof” suitable for out door type ( with metric knockouts for cable entry) of size 139 x 119 x 70 mm including necessary suitable size new aluminium busbar single phase with neutral system mounted on saddles - 02 Nos of suitable length and thickness, provision of aluminium cable lugs for incoming & out going LT cable connections with junction box fixing clamps made up of MS flat, nut and bolt on poles complete all as specified and as directed20Each
8978S&F in repairs cable junction boxes IP 66 protected “halogen free and weather proof” suitable for out door type (with metric knockouts for cable entry) of size 250 x 200 x 105 mm including necessary suitable size with cable terminal assembly mounted on saddles suitable for 3 phase with neutral system - 04 Nos of suitable length and thickness, provision of aluminium cable lugs for incoming & out going LT cable connections with junction box fixing clamps made up of MS flat, nut and bolt on poles complete all as specified and as directed30Each
9079S&F in repair informatory sign boards/display chart with single side writing over foam sheet of 4 mm thick (maximum size 2 m x 1 m) fixed on wall with screw. nuts and bolts etc. complete all as specified and as directed \nNote :- matters for writing shall be provided by department as per requirement.60Sqm
9180S&F in repair reflective informatory sign boards with single side writing as per IRC 67 made of high intensity grade sheeting, fixed over aluminium sheet 2 mm thick, supported on angle iron/GI pipes fixed in PCC including welding and painting with two coats of synthetic enamel paint over a coat of primer including necessary angle iron/pipe/PCC work for mounting of sign board complete all as specified and as directed15Sqm
9281Supply only electrical insulation rubber mating ISI marked and size 1 m x 2 m x 6 mm thick complete all as specified and as directed6Each
9382Supply only electrical insulation rubber mating ISI marked and size 1 m x 2 m x 10 mm thick complete all as specified and as directed4Each
9483Supply only for electrical insulation rubber mating ISI marked and size 1 m x 2 m x 12 mm thick complete all as specified and as directed5Each
9584Supply only for electrical insulation rubber mating ISI marked and size 1 m x 2 m x 19 mm thick complete all as specified and as directed5Each
9685S & F in repair anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and as directed25Each
9786S & F in repair danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and as directed20Each
9887S & F in repair danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and as directed25Each
9988M & L for painting of HT/LT panel of any description with one coat of synthetic enamel paint of standard colour code over the existing painted surfaces after preparing the old painted surfaces by using spray gun and marking of all incoming and out going MCB/MCCBS complete all as specified and as directed50Sqm
10089S & F Perforated cable Tray made out of GI Sheet of 14 SWG thickness and 40 to 50 mm depth hot dipped in various width sizes including accessories like coupler plate, nut bolts, washers clamps, wall bracket up/down elbows, bends tees equal distances on wall/floor/through wall crossing and making good the surface, complete all as specified and as directed28Sqm
10190M & L for graded coarse aggregate (broken stone or boulders) of size 40 mm in substation yard for laying complete all as specified and as directed31Cum
10291Dismantling broken/damaged pole/Struts/old concrete pole and removing from site as credit to schedule complete all as specified and as directed8Each
10392Labour for shifting of scrap any type (old unserviceable items elect motor, LT panel, elect cables, street light and iron scrap) from the site/sub station and deposited to AGE E/M - I Store yard by using suitable T & P, transports etc complete all as specified and as directed4Job Lorry

AI Tender Summary

OUR REF NO 26420545
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 18-01-2021
Authority
Authority Name Military Engineer Services
Work Description Repair Maintenance Of Lt Oht Lines Poles Cable And Connected Works Including Street Light And Upkeep Of Em Installations And Premonsoon Maintenance For Em Services Repair Maintenance Of Em Services At Hansa Vihar Nts South And North Side Of Runway Un
Basic Detail
Tender No 85355/E8
Bidding Type Tender
Location
City CWE NAVY VASCO
State Goa
Key Dates
Publish Date 11 Jan 2021
Submission Date 18 Jan 2021
Open Date 20 Jan 2021
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 90000
Exemption Not Available
Document List
BOQ_454996.xls
Tendernotice_1.pdf
85355TENDER.pdf
51EF7085-E063-47E7-AB91-E614DB9DFE3E.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 11, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 18, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 18, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 20, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_454996.xls

pdf

Tendernotice_1.pdf

pdf

85355TENDER.pdf

html

51EF7085-E063-47E7-AB91-E614DB9DFE3E.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail