Housing Urban and Rular Development Government Departments Closing in 0 days TDR #26417752

Supplying Installation Testing And Commissioning Of Exhaust Air Wet Scrubber In Canteen Area At Guru Govind Singh Govt . Hospital Raghubir Nagar , New Delhi

Issued by Government Departments · Guru Gobind Singh Govt. Hospital, Raghubir Nagar, Delhi
Tender Value
4.87 Lakhs
Estimated cost
Bid Submission
05 Jan 2021
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Guru Gobind Singh Govt. Hospital, Raghubir Nagar → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supplying Installation Testing And Commissioning Of Exhaust Air Wet Scrubber In Canteen Area At Guru Govind Singh Govt . Hospital Raghubir Nagar , New Delhi

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 29-Dec-2020 LIST OF APPROVED MATERIALS Other 05-Jan-2021

BOQ

Name of Work: Supplying Installation Testing and Commissioning of Exhaust Air Wet Scrubber in Canteen Area at Guru Govind Singh Govt. Hospital Raghubir Nagar, NEw Delhi
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Supplying, Installation, Testing and Commissioning of double skin cabinet type Exhaust air wet scrubber unit constructed of 0.63 (NS) mm thick pre plasterised powder coated outer sheet and 0.63 (NS) mm Plain G.I. inner sheet with 25 mm thick PUF insulation of density 40 Kg/cum in between. Comprising of blower section with backward curved DIDW centrifugal blower 65 mm static pressure, drive set, V-Belt driven by suitable HP rating TEFC squirrel cage weather proof motor. Double bank Spray nozzle system with eliminator & GI Intake Louver, suitable size pump, stainless steel sump with brass screen, inter-connecting G.I. pipe. Filters section with Al./ synthetic filters of 90% down to 10 micron efficiency, motors shall be suitable for 415 + 10% volts, 3 phase, 50 Hz, A.C. supply to suit humid conditions, complete with all accessories such as make-up, drain, over flow, quick fill valves, float valve, vibration isolators, foundations bolts complete etc as reqd. \n(i) Capacity 6000 CFM\n1job
22Providing, Supplying & fabricated Exhaust hood duly constructed with superior quality Stainless steel 18G SS 304 with standard viscous filters with grease gutter on rear and side in each piece and flushed led light with tough end glass and 600 lux light through out the hood complete with ceiling hangers, rods, angles and heat resistance wiring complete etc as reqd
32.012000mm x 600mm x 450mm with 3 filters2nos
42.021200mm x 600mm x 450mm with 2 filters1nos
53Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required
63.01Thickness 0.63 mm Sheet100sqm
73.02Thickness 0.80 mm Sheet20sqm
84Supplying, fixing, testing and commissioning fire retardant double canvas flexible connections suitable for 6000 CFM capacity unit complete etc. as reqd.1no
95Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
105.01E.R.W. tubes/ I Section Steel Beams80kg
116Supplying, Installation, Testing & Commissioning of dust, damp and vermin proof outdoor free standing cubical compartmentalized type, sheet steel panel suitable for operation of 415± V 10 %, 50 Hz, AC 3 phase 4 wire supply system fabricated out of CRCA sheet of 2 mm thick i/c cleaning and finishing compete with powder coating in approved shade, having 100 Amp capacity type TPN Aluminium alloy bus bars of high conductivity DMC/ SMC bus bar supports, inter connection with solid copper conductor wire / Al. strips, neutral link including control wiring with 2.5 Sqmm PVC insulated copper conductor FRLS coppr conductor S/C cable, cable gland plates in two half, necessary metering protections and indications and mounted with the following switch gears & accessories with proper earthing complete etc. as reqd. not less than 300 mm deep.1sqm
127Supplying & fixing following switchgears & accessories in the existing cubical panel etc. complete as reqd.
137.0163 Amps. 25 KA TP MCCB1no
147.0232 Amps. TP MCB1no
157.0396mm x 96mm 0-500volt digital 3-ph. Voltmeter with built in selector switch1set
167.0496mm x 96mm suitable range digital 3-ph. Ameter with builting selector switch & 3Nos. CT's1set
177.05LED type indicating light set for main incoming (Set of 3 Nos.)1set
187.06DOL starter for 5 HP motor complete with Power contactor, O/L relay, SPP, Push buttons, LED indicating lights etc.1set
198Supplying and fixing of 2 x 10 Sq.mm. XLPE insulated and PVC/ XLPE Sheated Aluminium Conductor Armoured power cable of 1.1 KV grade conf. to IS 7098(Part 1 ) 1988 & ISI Marked only of following manner etc complete as reqd. (Make : Polycab/Havells/R.R Kable/Finolex).50mtr
209Supplying, laying & fixing of following sizes PVC insulated PVC sheathed armoured copper conductor cable of 1.1 KV grade on surface etc. as reqd
219.013 x 4 sq.mm20mtr
2210Supplying & Laying and fixing of one number PVC insulated and PVC sheathed / XLPE copper conductor armoured power cable of 1.1 KV grade conf. to IS 7098 (Part-I)/ IS 1554 (Part-I) and ISI Marked only of following size on Surface etc as required
2310.013.5 x 25 sqmm40mtr
2411Supplying & Making end termination with brass compression gland of following. PVC insulated PVC sheathed Aluminium/ Cu. Conductor cable of 1.1 KV grade etc. as reqd.
2511.013½ x 25 sq. mm (28mm)2set
2611.022 X 10 sq. mm (19mm)6nos
2712Supplying, laying & fixing of 6 SWG dia G.I. wire on surface or in recess for loop earthing along with cable etc. as reqd.80mtr

AI Tender Summary

OUR REF NO 26417752
AUTHORITY Government Departments
TENDER VALUE 4.87 Lakhs
LAST DATE 05-01-2021
Authority
Authority Name Public Works Department
Work Description Supplying Installation Testing And Commissioning Of Exhaust Air Wet Scrubber In Canteen Area At Guru Govind Singh Govt . Hospital Raghubir Nagar , New Delhi
Basic Detail
Tender No 57/EE(E)/PWD HMED SW/2020-21
Bidding Type Tender
Location
City Guru Gobind Singh Govt. Hospital, Raghubir Nagar
State Delhi
Key Dates
Publish Date 29 Dec 2020
Submission Date 05 Jan 2021
Open Date 05 Jan 2021
Finance
Tender Value 4.87 Lakhs
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
9FCD18F2-EE80-4FC1-A21B-DEE4A0A8AA1F.html
BOQ_250321.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 29, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 05, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 05, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 05, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

9FCD18F2-EE80-4FC1-A21B-DEE4A0A8AA1F.html

xls

BOQ_250321.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders