Renovation And Upgradation Of Infrastructure Of Giti At Kaladhungi , Distt . -Nainital Uttarakhand, Kaladungh Nainital-Uttarakhand

Uttaranchal State Infrastructure Development Corporation Limited has published Renovation And Upgradation Of Infrastructure Of Giti At Kaladhungi , Distt . -Nainital Uttarakhand. Submission Date for this Tender is 04-02-2021. Infrastructure Work Tenders in Kaladungh Nainital Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

26415618
Corrigendum : Renovation And Upgradation Of Infrastructure Of Giti At Kaladhungi , Distt . -Nainital Uttarakhand
Open Tender
Indian
Uttarakhand
Kaladungh Nainital
04-02-2021

Tender Details

Renovation And Upgradation Of Infrastructure Of Giti At Kaladhungi , Distt . -Nainital Uttarakhand

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Jan-2021 BOQ Replaced BOQ 28-01-2021
2 27-Jan-2021 date extension Date 04-02-2021
3 27-Jan-2021 corrigendum1 Other 04-02-2021

Key Value

Document Fees
INR 5900 /-
EMD
INR 208000.0 /-
Tender Value
INR 2.07 Crore /-

BOQ Items

Name of Work:Renovation & Upgradation of Infrastructure of GITI at Kaladhungi, Distt. –Nainital l Uttarakhand
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. BI01010001010000000000000515BI0100001126 84.95 Cum
2 2 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.\n All kinds of soil. BI01010001010000000000000515BI0100001127 462.06 Cum
3 3 Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil BI01010001010000000000000515BI0100001128 38.54 Cum
4 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. BI01010001010000000000000515BI0100001129 397.05 Cum
5 5 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete BI01010001010000000000000515BI0100001130 90.88 Cum
6 6 Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming, consolidating and dressing complete. BI01010001010000000000000515BI0100001131 34.8 Cum
7 7 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil, Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia BI01010001010000000000000515BI0100001132 161 R.M
8 8 Applying antitermite treatment with specified chemicals under floors, sides of foundation etc. : With Chlorpyriphos / Lindane E.C. 20% with 1% concentration BI01010001010000000000000515BI0100001133 375.74 Sqm
9 9 Supplying chemical emulsion in sealed containers including delivery as specified Chlorpyriphos/ Lindane emulsifiable concentrate of 20% BI01010001010000000000000515BI0100001134 206.66 lit
10 10 P/L cement concrete - all works upto plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) BI01010001010000000000000515BI0100001135 0.4 Cum
11 11 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) BI01010001010000000000000515BI0100001136 79.03 Cum
12 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) BI01010001010000000000000515BI0100001137 6 Cum
13 13 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) BI01010001010000000000000515BI0100001138 4.42 Cum
14 14 Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). BI01010001010000000000000515BI0100001139 27.74 Sqm
15 15 Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. BI01010001010000000000000515BI0100001140 27.74 Sqm
16 16 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth BI01010001010000000000000515BI0100001141 166.46 Sqm
17 17 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) BI01010001010000000000000515BI0100001142 4.31 Cum
18 18 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) BI01010001010000000000000515BI0100001143 9.88 Cum
19 19 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). BI01010001010000000000000515BI0100001144 1.06 Cum
20 20 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level BI01010001010000000000000515BI0100001145 55.49 Cum
21 21 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.All works above plinth level upto floor V level BI01010001010000000000000515BI0100001146 44.98 Cum
22 22 Add for using extra cement in the items of design mix over and above the specified cement content therein. BI01010001010000000000000515BI0100001147
23 23 Centering and shuttering including strutting, propping etc. and removal of form for : BI01010001010000000000000515BI0100001148
24 24 Foundations, footings, bases of columns, etc. for mass concrete BI01010001010000000000000515BI0100001149 223.45 Sqm
25 25 Suspended floors, roofs, landings, balconies and access platform. BI01010001010000000000000515BI0100001150 66.21 Sqm
26 26 Columns, Pillars, Piers, Abutments, Posts and Struts BI01010001010000000000000515BI0100001151 161.09 Sqm
27 27 Lintels, beams, plinth beams, girders, bressumers and cantilevers. BI01010001010000000000000515BI0100001152 189.13 Sqm
28 28 Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12 mm thick BI01010001010000000000000515BI0100001153 69.12 Sqm
29 29 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more. BI01010001010000000000000515BI0100001154 1522.5 Kg.
30 30 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars BI01010001010000000000000515BI0100001155 11830 Kg
31 31 Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) BI01010001010000000000000515BI0100001156 91.23 Cum
32 32 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) BI01010001010000000000000515BI0100001157 111.16 Cum
33 33 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:3 (1 cement :3 coarse sand) BI01010001010000000000000515BI0100001158 84 Sqm
34 34 Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). BI01010001010000000000000515BI0100001159 83.66 R.M
35 35 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/ sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of\n12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing BI01010001010000000000000515BI0100001160
36 36 of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, Galvanised M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each with zinc coating of 120 gms/sqm(both side inclusive)) to be provided at the horizontal joints of two BI01010001010000000000000515BI0100001161
37 37 boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint\nfinisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete: 75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: (part 3) : 1996 (Board with BIS certification marks) BI01010001010000000000000515BI0100001162 115.5 sqm
38 38 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) NON decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. BI01010001010000000000000515BI0100001163 8.7 Sqm
39 39 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper BI01010001010000000000000515BI0100001164 8 each
40 40 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete. 250x10 mm BI01010001010000000000000515BI0100001165 18 each
41 41 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :100 mm BI01010001010000000000000515BI0100001166 16 each
42 42 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :100 mm BI01010001010000000000000515BI0100001167 2 Nos.
43 43 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to rand screws etc. complete :300x16 mm BI01010001010000000000000515BI0100001168 16 each
44 44 Providing and fixing aluminium sliding door bolts, ISI marked anodised(anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm BI01010001010000000000000515BI0100001169 1 Nos.
45 45 12mm thick plaster on the plain in side of mix 1:6( 1 cement : 6 fine sand) mortar BI01010001010000000000000515BI0100001170 762.72 Sqm.
46 46 15mm thick plaster on the plain in side of mix 1:6( 1 cement : 6 fine sand) mortar BI01010001010000000000000515BI0100001171 466.78 Sqm.
47 47 6 mm cement plaster 1:3 (1 cement: 3 fine sand) BI01010001010000000000000515BI0100001172 12.72 Sqm
48 48 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. BI01010001010000000000000515BI0100001173 208.62 Sqm.
49 49 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats BI01010001010000000000000515BI0100001174 3048.56 Sqm.
50 50 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :\nWater thinnable cement primer BI01010001010000000000000515BI0100001175 2507.76 Sqm.
51 51 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) BI01010001010000000000000515BI0100001176 1574.22 Sqm.
52 52 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture BI01010001010000000000000515BI0100001177 15.84 Sqm.
53 53 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture BI01010001010000000000000515BI0100001178 37.98 Sqm.
54 54 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 5.5 mm thick glass panes BI01010001010000000000000515BI0100001179 10.8 Sqm.
55 55 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. BI01010001010000000000000515BI0100001180 19231.7 Kg.
56 56 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm BI01010001010000000000000515BI0100001181 99.88 Sqm.
57 57 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm or 300x600mm BI01010001010000000000000515BI0100001182 619.98 Sqm.
58 58 40 mm thick marble chips flooring rubbed and polished to granolithic finish, under layer 34 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) and top layer 6mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 1 mm to 4 mm nominal size, laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips) by volume, including cement slurry etc. complete :Medium shade pigment with 50% white cement and 50% ordinary cement BI01010001010000000000000515BI0100001183 63 Sqm.
59 59 Marble chips skirting up to 30 cm height, rubbed and polished to granolithic finish, top layer 6 mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from smallest to 4 mm nominal size, laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips) by volume : 11.12.1 18 mm thick with under layer 12 mm thick in cement plaster 1:3 (1 cement : 3 coarse sand) :Medium shade pigment with 50% white cement and 50% ordinary cement BI01010001010000000000000515BI0100001184 6.9 Sqm.
60 60 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red,Elite Brown, Cat Eye or equivalent. BI01010001010000000000000515BI0100001185 126 Sqm.
61 61 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required BI01010001010000000000000515BI0100001186 59 Sqm.
62 62 Providing and laying in situ seven course water proofing treatmentwith APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). sqm 592.65 BI01010001010000000000000515BI0100001187 1315.5 Sqm
63 63 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-chargeGI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100\ngms/sqm (both sides inclusive) and electro statically\npolyester powder coated of thickness 60 microns\n(minimum), including factory painted after bending BI01010001010000000000000515BI0100001188
64 64 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. BI01010001010000000000000515BI0100001189 553.11 Sqm
65 65 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) BI01010001010000000000000515BI0100001190
66 66 Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. BI01010001010000000000000515BI0100001191 182.5 Sqm
67 67 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.20 mm cement plaster BI01010001010000000000000515BI0100001192 117 Sqm
68 68 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. : 80x1.25 mm M.S. laths with 1.25 mm thick top cover BI01010001010000000000000515BI0100001193 36 sqm
69 69 Providing and fixing ball bearing for rolling shutters. BI01010001010000000000000515BI0100001194 4 Nos.
70 70 Extra for providing mechanical device chain and crank operation for operating rolling shutters. : Exceeding 10.00 sqm and upto 16.80 sqm in the area BI01010001010000000000000515BI0100001195 36 sqm
71 71 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.80 mm thick with zinc coating not less than 275 gm/m² BI01010001010000000000000515BI0100001196 512.84 Sqm
72 72 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete: 0.80 mm thick with zinc coating not less than 275 gm/m² BI01010001010000000000000515BI0100001197 30 rm
73 73 Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.: 0.80 mm thick with zinc coating not less than 275 gm/m² BI01010001010000000000000515BI0100001198 60 rm
74 74 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture BI01010001010000000000000515BI0100001199 487.37 Sqm
75 75 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.\n110 mm diameter BI01010001010000000000000515BI0100001200 126 R.M
76 76 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110 mm BI01010001010000000000000515BI0100001201 20 No's
77 77 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. BI01010001010000000000000515BI0100001202
78 78 110 mm bend BI01010001010000000000000515BI0100001203 20 Nos
79 79 110 mm Shoe BI01010001010000000000000515BI0100001204 20 Nos
80 80 110x110x110 mm tee BI01010001010000000000000515BI0100001205
81 81 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm BI01010001010000000000000515BI0100001206 30 Nos
82 82 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe BI01010001010000000000000515BI0100001207 56 R.M
83 83 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : BI01010001010000000000000515BI0100001208 56 R.M
84 84 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame o f 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 BI01010001010000000000000515BI0100001209 25 Nos
85 85 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mmnominal size), inside plastering 12 mm thick with cement mortar 1:3 (1cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 BI01010001010000000000000515BI0100001210 18 Nos
86 86 Extra for depth for manholes : With Sewer bricks conforming to IS : 4885 BI01010001010000000000000515BI0100001211 3.6 R.M
87 87 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests BI01010001010000000000000515BI0100001212 4 Nos
88 88 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid BI01010001010000000000000515BI0100001213 12 Nos
89 89 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. BI01010001010000000000000515BI0100001214 12 Nos
90 90 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps BI01010001010000000000000515BI0100001215 10 Nos
91 91 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. BI01010001010000000000000515BI0100001216 10 Nos
92 92 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other ouplings in C.P. brass,including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern BI01010001010000000000000515BI0100001217 14 Nos
93 93 Providing and fixing soil, waste and vent pipes: Centrifugally cast (spun) iron socketed pipe as per IS: 3989. BI01010001010000000000000515BI0100001218
94 94 100MM BI01010001010000000000000515BI0100001219 36 Meter
95 95 75mm BI01010001010000000000000515BI0100001220 54 Meter
96 96 Providing & filling the tee /bend /collar/tapper etc., with rubber jount filler including all complete BI01010001010000000000000515BI0100001221
97 97 100 mm BI01010001010000000000000515BI0100001222
98 98 Providing and fixing plain bend of required degree.100 mm dia Sand cast iron S&S as per IS - 3989 BI01010001010000000000000515BI0100001223 16 Nos
99 99 Providing and fixing double equal plain invert branch of required degree:100x100x100x100 mm Sand cast iron S&S as per IS 3989 BI01010001010000000000000515BI0100001224 8 Nos
100 100 75mm BI01010001010000000000000515BI0100001225
101 101 Providing and fixing plain bend of required degree.75 mm dia Sand cast iron S&S as per IS - 3989 BI01010001010000000000000515BI0100001226 10 Nos
102 102 Providing and fixing double equal plain invert branch of required degree:75x75x75x75 mm Sand cast iron S&S as per IS - 3989 BI01010001010000000000000515BI0100001227 5 Nos
103 103 Providing and fixing 600 x 455 mm. bevelled edge mirror of Saint Gobin or Modi float glass complete with 6 mm. thick hard board ground fix to wooden cleats with CP brass screws and washers etc. complete. BI01010001010000000000000515BI0100001228 10 Nos
104 104 Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms. BI01010001010000000000000515BI0100001229 10 Nos
105 105 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm,78 mm wide and effective height of 88 mm, weighing not less than 170 gms BI01010001010000000000000515BI0100001230 10 Nos
106 106 Providing and fixing toilet paper holder :C.P. brass BI01010001010000000000000515BI0100001231 12 Nos
107 107 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :Sand cast iron S&S as per IS - 3989 BI01010001010000000000000515BI0100001232 24 Nos
108 108 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron(100 mm) BI01010001010000000000000515BI0100001233 20 Nos
109 109 Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast BI01010001010000000000000515BI0100001234 40 Nos
110 110 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : BI01010001010000000000000515BI0100001235 20 Metre
111 111 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore BI01010001010000000000000515BI0100001236 16 Nos
112 112 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. BI01010001010000000000000515BI0100001237 10 Nos
113 113 12 mm cement plaster finished with a floating coat of neat cement of mix1:3 (1 cement : 3 fine sand) BI01010001010000000000000515BI0100001238 80 Sqm
114 114 Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.40mm thick with 20mm nominal size stone aggregate. BI01010001010000000000000515BI0100001239 110 Sqm
115 115 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick BI01010001010000000000000515BI0100001240 2.8 Sqm
116 116 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 BI01010001010000000000000515BI0100001241 1 Nos
117 117 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diameter : BI01010001010000000000000515BI0100001242 105 Meter
118 118 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 150 mm diameter S.W. pipe BI01010001010000000000000515BI0100001243 105 Meter
119 119 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. BI01010001010000000000000515BI0100001244 2524.21 Kg.
120 120 Providing & fixing of R.C.C manhole covering tank (600 x 450) BI01010001010000000000000515BI0100001245 4 nos
121 121 Providing & fixing of foot rest in tank (20x20) BI01010001010000000000000515BI0100001246 10 nos
122 122 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc BI01010001010000000000000515BI0100001247
123 123 15 mm dia nominal bore BI01010001010000000000000515BI0100001248 139 Meter
124 124 20 mm dia nominal bore BI01010001010000000000000515BI0100001249 26 Meter
125 125 25 mm nominal bore BI01010001010000000000000515BI0100001250 20 Meter
126 126 40 mm dia nominal bore BI01010001010000000000000515BI0100001251 25 Meter
127 127 50 mm dia nominal bore BI01010001010000000000000515BI0100001252 30 Meter
128 128 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : BI01010001010000000000000515BI0100001253
129 129 15 mm nominal bore BI01010001010000000000000515BI0100001254 34.75 Nos.
130 130 20 mm nominal bore BI01010001010000000000000515BI0100001255 7 Nos.
131 131 25 mm nominal bore BI01010001010000000000000515BI0100001256 5 Nos.
132 132 40 mm nominal bore BI01010001010000000000000515BI0100001257 6 Nos.
133 133 50 mm nominal bore BI01010001010000000000000515BI0100001258 8 Nos.
134 134 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore BI01010001010000000000000515BI0100001259 8 Nos
135 135 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : BI01010001010000000000000515BI0100001260
136 136 20 mm nominal bore BI01010001010000000000000515BI0100001261 10 Nos
137 137 Providing and fixing gun metal non- return valve of approved quality (screwed end) : BI01010001010000000000000515BI0100001262
138 138 25 mm nominal bore (Horizontal) BI01010001010000000000000515BI0100001263 10 Nos
139 139 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. BI01010001010000000000000515BI0100001264 4000 Ltr.
140 140 Finishing walls with acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). BI01010001010000000000000515BI0100001265 629.92 Sqm
141 141 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work BI01010001010000000000000515BI0100001266 47.88 Sqm
142 142 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade BI01010001010000000000000515BI0100001267 54 Sqm
143 143 Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineerin- Charge. 80mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern. BI01010001010000000000000515BI0100001268 60 Sqm
144 144 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete Hot finished seamless type tubes BI01010001010000000000000515BI0100001269 1716 Kg
145 145 Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys,rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-incharge.( Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for\npayment). BI01010001010000000000000515BI0100001270 7.2 Sqm
146 146 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work BI01010001010000000000000515BI0100001271 4.03 Sqm
147 147 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. BI01010001010000000000000515BI0100001272 3.6 Sqm
148 148 Brick work with common burnt clay selected F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand)Above plinth level upto floor V level BI01010001010000000000000515BI0100001273 1.38 Cum
149 149 Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means,including M.S. pressed butt hinges 2.5 mm thick with mortar guards,lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B Fixing with adjustable lugs with split end tail to each jamb BI01010001010000000000000515BI0100001274 14.1 Metre
150 150 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .(Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not\nless than 10 kg/ sqm) BI01010001010000000000000515BI0100001275 2.88 Sqm
151 151 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m² BI01010001010000000000000515BI0100001276 12 Sqm
152 152 Horticulture BI01010001010000000000000515BI0100001277
153 153 Trenching in ordinary soil up to a depth of 60cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling with in a lead of 50m and making up the trenched area to proper levels by filling with earth BI01010001010000000000000515BI0100001278 100 Cum
154 154 Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment). BI01010001010000000000000515BI0100001279 100 Cum
155 155 Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment). BI01010001010000000000000515BI0100001280 100 Cum
156 156 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. BI01010001010000000000000515BI0100001281 500 Sqm
157 157 Fine dressing the ground. BI01010001010000000000000515BI0100001282 500 Sqm
158 158 Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately). BI01010001010000000000000515BI0100001283 75 Cum
159 159 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. BI01010001010000000000000515BI0100001284 75 Cum
160 160 Grassing with ‘Doob’ grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing including supplying good earth if needed (the good earth shall be paid for separately). In r BI01010001010000000000000515BI0100001285 500 Sqm
161 161 Preparation of beds for hedging and shrubbery by excavating cu.m 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of sta BI01010001010000000000000515BI0100001286 5 Cum
162 162 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) 60 CM DIA AND 60 CM DEPTH BI01010001010000000000000515BI0100001287 50 No.
163 163 Demolishing Items BI01010001010000000000000515BI0100001288
164 164 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar BI01010001010000000000000515BI0100001289 20.6 Cum
165 165 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area beyond 3 sq. metres BI01010001010000000000000515BI0100001290 4 Nos
166 166 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area beyond 3 sq. metres BI01010001010000000000000515BI0100001291 2 Nos
167 167 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. BI01010001010000000000000515BI0100001292 42 Sqm
168 168 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. BI01010001010000000000000515BI0100001293 0.72 Cum
169 169 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) BI01010001010000000000000515BI0100001294 28.35 Cum
170 170 SOR ITEMS BI01010001010000000000000515BI0100001295
171 171 Excavation in Soil with Dozer with lead upto 100 m\nExcavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections BI01010001010000000000000515BI0100001296 54 Cum
172 172 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 1 as per Technical Specification Clause 405. BI01010001010000000000000515BI0100001297 36 cum
173 173 Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion cu.m 1:4:8 in foundations and floors including supply of all material, labour and T&P etc. required for proper completion of the work.(Based on PWD specifications)\n BI01010001010000000000000515BI0100001298 27 cum
174 174 Brick masonry work in cement mortar in substructure complete excepting pointing and plastering, as per drawing and technical specification Clauses 602, 603, 604, 1202 & 1204 BI01010001010000000000000515BI0100001299 6.21 Cum
175 175 Excavation for Structures\nEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. BI01010001010000000000000515BI0100001300 4.14 Cum
176 176 Brick on edge pavement with straight overburnt bricks laid on edge including preparation of subgrade to prescribed camber and including supply of bricks, filling joints with local sand and spreading blinding coat 1cm (3/8") depth of local sand over the entire surface and including supply of all materials, labour and T&P etc. required for proper completion of the work BI01010001010000000000000515BI0100001301 60 Sqm
177 177 Providing and fillling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight. BI01010001010000000000000515BI0100001302 30 Metre
178 178 Laying Cement Concrete Pipe NP3 (burried conduits) on first class bedding of granular material including fixing collar with cement sand mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonary work in head wall and parapets BI01010001010000000000000515BI0100001303 35 Metre
179 179 Cement Concrete (PCC M-30) Pavement:-\nConstruction of Un-reinforced, Cement concrete pavement, thickness as per design, over a prepeared sub base with 43 grade cement or any other type PCC Grade M-30, coarse and fine aggregates conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less then 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side\nformwork (Steel channel, laying and fixing of wedges, steel plates including levelling the formwork and laying and fixing of 125 micron thick polythene film, as per drawing), spreading the concrete with shovels,rakes, compacted using needle, and plate vibrators, finished in continuous operation and curing of concrete slabs for 14 days, usingcuring compound where specified and water finishing to lines and grade as per drawings and technical specifications. BI01010001010000000000000515BI0100001304 18 cum
180 180 MR Items BI01010001010000000000000515BI0100001305
181 181 EmergencyY Light & Illuminated Signages BI01010001010000000000000515BI0100001306
182 182 PAR 2019 BI01010001010000000000000515BI0100001307
183 183 Illuminated signages BI01010001010000000000000515BI0100001308 10 Sqmt
184 184 Testing Charges as per EMP BI01010001010000000000000515BI0100001309
185 185 Pre Construction Stage BI01010001010000000000000515BI0100001310
186 186 Environmental Baseline Data Generation (Pre Construction Stage) BI01010001010000000000000515BI0100001311
187 187 Ambient Air Quality Test BI01010001010000000000000515BI0100001312 1 Each
188 188 Noise Level Test BI01010001010000000000000515BI0100001313 1 Each
189 189 Drinking Water Quality Test BI01010001010000000000000515BI0100001314 1 Each
190 190 Construction Stage BI01010001010000000000000515BI0100001315
191 191 Environmental Monitoring (Construction Stage) BI01010001010000000000000515BI0100001316
192 192 Ambient Air Quality Test BI01010001010000000000000515BI0100001317 3 Each
193 193 Noise Level Test BI01010001010000000000000515BI0100001318 3 Each
194 194 Drinking Water Quality Test BI01010001010000000000000515BI0100001319 3 Each
195 195 Dust Suppression BI01010001010000000000000515BI0100001320
196 196 Dust Suppression at Site ( Assumption @ 2 hours/ day or as and when required) BI01010001010000000000000515BI0100001321 100 Hrs
197 197 Septic Waste Cleaning BI01010001010000000000000515BI0100001322
198 198 Approximately 3000 Litres in One Tanker (3 Tankers shall be required as per EMP) BI01010001010000000000000515BI0100001323 12 Per KL
199 199 Capacity Building BI01010001010000000000000515BI0100001324
200 200 Training at Site for Implementation of EMP BI01010001010000000000000515BI0100001325 1 Job
201 201 Providing and fixing C.P. brass bib cock of push button of approved quality complete as per direction by engineer in charge\n BI01010001010000000000000515BI0100001326 30 Nos
202 202 Providing and fixing C.P. brass angle cock/ valve for basin mixer , geyser points or to other similar fittings of approved quality conforming to IS:8931(Jaguar/Parryware) :15 mm nominal bore(Push type as per approval of E-in CHARGE\n BI01010001010000000000000515BI0100001327 22 Nos
203 203 Letter Writing on Granite by Brass letters BI01010001010000000000000515BI0100001328 3.6 Sqm
204 204 Providing and fixing Tata pravesh window and ventilators and frame with hardware ( hinges, lever handle with lock, tower bolt) and instalation (Glass, Grill and wire gauge) BI01010001010000000000000515BI0100001329 23.76 Sqm
205 205 Providing and fixing Tata Steel Pravesh Door (Hardware GEZE Make)Ball bearing butt hinge of size 102x75x3mm with screws in SSS- Dead Bolt (Mortise Dead Lock with Euro profike cylinder(Green), BI01010001010000000000000515BI0100001330
206 206 Concealed Flush Bolt (98307009), D - Handle(D-Both Side - Dia 19mmX254mm(L)Geze)(Double leaf) BI01010001010000000000000515BI0100001331 6 Sqm
207 207 (Tata Steel Door swings type of any size)(Single leaf) BI01010001010000000000000515BI0100001332 3 Sqm
208 208 Providing & fixing Tata Steel window/sliding window Of any size 27mm Series with Toughened Glass and with mesh shutter 2.5 Track BI01010001010000000000000515BI0100001333 7.9 Sqm
209 209 Electrical (D.S.R Items) BI01010001010000000000000515BI0100001334
210 210 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor\nsingle core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box\nand earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. ,Group B BI01010001010000000000000515BI0100001335 359 Point
211 211 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /\nrecessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. BI01010001010000000000000515BI0100001336 2 Point
212 212 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. BI01010001010000000000000515BI0100001337 732 Mtr
213 213 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired., 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire BI01010001010000000000000515BI0100001338 660.188 Mtr
214 214 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired. , 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire BI01010001010000000000000515BI0100001339 295 Mtr
215 215 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired. ,2 X 6 sq. mm + 1 X 6 sq. mm earth wire BI01010001010000000000000515BI0100001340 216 Mtr
216 216 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired., 4 X 6 sq. mm + 2 X 6 sq. mm earth wire BI01010001010000000000000515BI0100001341 231 Mtr
217 217 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired., 4 X 10 sq. mm + 2 X 6 sq. mm earth wire BI01010001010000000000000515BI0100001342 140 Mtr
218 218 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. , 2 pair BI01010001010000000000000515BI0100001343 420 Mtr
219 219 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required., 20 MM BI01010001010000000000000515BI0100001344 80 Mtr
220 220 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including\ncutting the wall and making good the same in case of recessed conduit as required., 20 mm BI01010001010000000000000515BI0100001345 375 Mtr
221 221 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.., 5/6 A switch BI01010001010000000000000515BI0100001346 80 Each
222 222 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 3 pin 5/6 A socket outlet BI01010001010000000000000515BI0100001347 80 Each
223 223 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., Telephone socket outlet BI01010001010000000000000515BI0100001348 29 Each
224 224 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. BI01010001010000000000000515BI0100001349 151 Each
225 225 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. ,1 or 2 Module (75mmX75mm) BI01010001010000000000000515BI0100001350 39 Each
226 226 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required., 6 Module (200mmX75mm) BI01010001010000000000000515BI0100001351 40 Each
227 227 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. BI01010001010000000000000515BI0100001352 38 Each
228 228 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. BI01010001010000000000000515BI0100001353 61 Each
229 229 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. BI01010001010000000000000515BI0100001354 271 Each
230 230 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, LED Fixtures, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. BI01010001010000000000000515BI0100001355 187.6 Each
231 231 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. BI01010001010000000000000515BI0100001356 105.7 Each
232 232 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep BI01010001010000000000000515BI0100001357 14.7 Each
233 233 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. BI01010001010000000000000515BI0100001358 14.7 Each
234 234 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted\nincluding earthing etc. as required. (But without MCB/RCCB/Isolator), 4 way (4 + 12), Double door BI01010001010000000000000515BI0100001359 3 Each
235 235 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted\nincluding earthing etc. as required. (But without MCB/RCCB/Isolator), 6 way (4 + 18), Double door BI01010001010000000000000515BI0100001360 6 Each
236 236 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of\nfollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required., Single pole BI01010001010000000000000515BI0100001361 100.8 Each
237 237 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of\nfollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required., Triple pole BI01010001010000000000000515BI0100001362 22.4 Each
238 238 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A BI01010001010000000000000515BI0100001363 1 Each
239 239 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A BI01010001010000000000000515BI0100001364 8 Each
240 240 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top\nalongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. BI01010001010000000000000515BI0100001365 18 Each
241 241 Supplying and fixing 30 A/32A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top\nalongwith 30 A/32A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. BI01010001010000000000000515BI0100001366 35 Each
242 242 Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required., 150 mm width X 50 mm depth X 1.6 mm thickness BI01010001010000000000000515BI0100001367 50 RM
243 243 Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays bends with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required. ,150 mm width X 50 mm depth X 1.6 mm thickness BI01010001010000000000000515BI0100001368 10 Each
244 244 Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays tees with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required., 150 mm width X 50 mm depth X 1.6 mm thickness BI01010001010000000000000515BI0100001369 5 Each
245 245 Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays cross members with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required., 150 mm width X 50 mm depth X 1.6 mm thickness BI01010001010000000000000515BI0100001370 10 Each
246 246 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete BI01010001010000000000000515BI0100001371 151 Each
247 247 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including\ncutting the wall and making good the same in case of recessed\nconduit as required. 25 mm BI01010001010000000000000515BI0100001372 1173 Mtr
248 248 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. , 1 run of cable BI01010001010000000000000515BI0100001373 880 Metre
249 249 Supplying and drawing following sizes of FRLS PVC insulated\ncopper conductor, single core cable in the existing surface/\nrecessed steel/ PVC conduit as required. 2 x 1.5 sq. mm BI01010001010000000000000515BI0100001374 500 Mtr
250 250 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. BI01010001010000000000000515BI0100001375 10 set
251 251 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. BI01010001010000000000000515BI0100001376 2 set
252 252 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) BI01010001010000000000000515BI0100001377 25 mtr
253 253 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) BI01010001010000000000000515BI0100001378 50 mtr
254 254 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. BI01010001010000000000000515BI0100001379 20 mtr
255 255 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. BI01010001010000000000000515BI0100001380 20 mtr
256 256 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. BI01010001010000000000000515BI0100001381 100 mtr
257 257 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with\n85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. BI01010001010000000000000515BI0100001382 2 Each
258 258 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck\nnuts and spring washers etc. complete as required. BI01010001010000000000000515BI0100001383 8 Each
259 259 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. BI01010001010000000000000515BI0100001384 20 Mtr
260 260 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing\nRCC/ HUME/ METAL pipe/existing open trence/as required. Above 35 sq. mm and upto 95 sq. mm BI01010001010000000000000515BI0100001385 150 Mtr
261 261 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size\non wall surface and overhead as required. Upto 35 sq. mm (clamped with 1mm thick saddle) BI01010001010000000000000515BI0100001386 80 Mtr
262 262 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm\nMS flat clamp) BI01010001010000000000000515BI0100001387 50 Mtr
263 263 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated\nand PVC sheathed / XLPE aluminium conductor cable of 1.1 KV, 3½ X 35 sq. mm (32mm) BI01010001010000000000000515BI0100001388 4 each
264 264 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated\nand PVC sheathed / XLPE aluminium conductor cable of 1.1 KV, 3½ X 70 sq. mm (38mm) BI01010001010000000000000515BI0100001389 2 each
265 265 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated\nand PVC sheathed / XLPE aluminium conductor cable of 1.1 KV, 3½ X 185 sq. mm (45mm) BI01010001010000000000000515BI0100001390 2 each
266 266 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated\nand PVC sheathed / XLPE aluminium conductor cable of 1.1 KV, 4 X 10 sq. mm (25mm) BI01010001010000000000000515BI0100001391 10 each
267 267 Erection of metallic/octagonal pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling\netc. as required. ,Above 4.5 metre and upto 6.5 metre BI01010001010000000000000515BI0100001392 10 each
268 268 Providing and making steel pole collar with cement concrete (1cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted) BI01010001010000000000000515BI0100001393 3.6 cum
269 269 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 40 mm dia BI01010001010000000000000515BI0100001394 20 mtr
270 270 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required. 100 mm dia BI01010001010000000000000515BI0100001395 120 Metre
271 271 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required. 150 mm dia BI01010001010000000000000515BI0100001396 50 Metre
272 272 Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) BI01010001010000000000000515BI0100001397 20 Metre
273 273 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size in the existing RCC/\nHUME/ METAL pipe as required., Upto 120 sq. mm BI01010001010000000000000515BI0100001398 40 Mtr.
274 274 Supplying & making of INDOOR cable end terminations with HEAT SHRINKABLE JOINTING KIT with all accessories including lugs suitable for following sizes of 3 core, XLPE Al conductor cable of 11 KV grade as required., 3 X120 sq mm. BI01010001010000000000000515BI0100001399 4 Each
275 275 Supplying & making of OUTDOOR cable end terminations with HEAT SHRINKABLE JOINTING KIT with all accessories including lugs suitable for following sizes of 3 core, XLPE Al conductor cable of 11 KV grade as required. 3 X120 sq mm. BI01010001010000000000000515BI0100001400 4 Each
276 276 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required,150 mm dia BI01010001010000000000000515BI0100001401 40 mtr
277 277 SUB HEAD B - NON SCHEDULE ITEMS BI01010001010000000000000515BI0100001402
278 278 Supplying, installation, testing & commissioning of modular, fully bolted type, sectionallised Low Voltage Panel suitable for 415 V, 3 Phase, 4 wire 50 Hz AC supply system as per standard IEC 61439- 1 &2 as Total Type Tested Assembly and of suitable size fabricated in compartmentalized design with CRCA sheet steel of 2mm thick for load bearing member and 1.6mm for Non load bearing member. 3mm thick for gland plates. i/c cleaning & finishing complete with 9 tank process (automatic PT spray) for powder coating in approved shade, having suitable rating capacity extensible type TPN Aluminium bus bars of high conductivity as per BOQ, bus bar supports, with short circuit withstand capacity of 50kA for 1 Sec., bottom base frame of 3mm thick (multifold design), fabrication shall be done in trasportable sections, entire LENGTH panel shall have a common earth bar at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars/Copper Cables and control wiring with 2.5 Sq.mm. PVC insulated copper FRLS conductor S/C cable for voltage & Current respectively, cable alleys, i/c providing following switch gears , Panel shall be suitable for Internal Arc Test 50kA for 400mS as per IEC61641 and Siesmic Zone-IV tested , Form of Separation Form 4b, Mechanical Impact IK08-IK10 as per IEC, ACBs shall have Temperature protection for release & having display with battery backup and 20Faults Trip History : ( The board shall be dust and vermin proof with degree of protection IP 42 )\nINCOMER:- 1 nos. 630 A 415V, Ics=Icu=Icw=50KA, 4P ACB with MP release with LCD display having O/L, S/C , G/F Over temperature and neutral failure protection, release should have minimum 10 Nos fault history for diagnosis of fault, .1 nos. Digital type multi function meters (V+A+Hz) with cast resin CTs 1000/5A. , 1 Set of phase indicating lamp with MCB 1 No. 400 A, 4pole onload changeover switch. BUSBAR:-400 A TPN Bus bar of aluminimum alloy. OUTGOING:- 1 nos. 200 A, 415V, FP MCCB of 36kA.with adjustable O/L and S/C protection., 4 nos. 125A, 415V, FP MCCB of 25kA.with adjustable O/L and S/C protection.,2 nos. 63A, 415V, FP MCCB of 25kA.with adjustable O/L and S/C protection. , 5 nos. 40A, 415V, 4P MCB of 10kA.with O/L and S/C protection. 6 nos. 63A, 415V, 4P MCB of 10kA.with O/L and S/C protection.4 nos. 32A, 230V, 2P MCB of 10kA.with O/L and S/C protection. Incommer for APFC Section 1 nos. 400A, 415V, FP MCCB of 36kA.with adjustable O/L and S/C protection. 1 nos. Digital type multi function meters (V+A+Hz) with cast resin CTs 1000/5A. 1 Set of phase indicating lamp with MCB 1 No. APFC Relay suitable for controlling of 8 Nos relay output. 50 KVAR Capacitor Bank in 12 steps having MCB/MCCB for protection, Contactors as per AC6 Duty for automatic switching, having auto manual switch and indication for each step. BI01010001010000000000000515BI0100001403 1 NOS.
279 279 Supply and Erecting modular type computer jack RJ 45 with screwless connector approved make with mounting plate and box with wiring connections complete. BI01010001010000000000000515BI0100001404 44 NOS.
280 280 Supplying & fixing of 6 Core - Optic fiber cable OM4 - Unitube Corrugated steel tape Optical Fiber Cable as per IEC 60794-1 BI01010001010000000000000515BI0100001405 200 Mtr
281 281 Supplying & fixing of U/ UTP, Cat 6 A Cable as per ANSI/TIA 568C.2 at 500 to 600 MHz suitable for (Complete in all respect) cctv BI01010001010000000000000515BI0100001406 690 Mtr
282 282 Supply and fixing of 2 Zone Conventional Fire Alarm Control Panel , Panel Operating Voltage :AC 220v 50Hz #10%, DC 24v 1 amp Operating Temperature :0º C to 50º (176)C Operating Humidity :95% (non-condensing) Hooter output :2A (24v DC) ,EOL :4k7 ohm, 1 per Zone, Construction :1.8mm CRCA sheet duly powder Coated ,16 * 2 character LCD Display ,\nExtra potential free contact for fire & fault ,Auto dialer connectivity facility ,Inbuilt battery charger & battery space facility ,Reset, alarm cancel, lamp test feature\n,Zone wise test and isolation facility ,Protected from Hi-voltage, over-load, short-circuit, Zone wise LED indications for fire, open and short. BI01010001010000000000000515BI0100001407 1 NOS.
283 283 Supply and fixing of High intensity Sounder with mounting base. BI01010001010000000000000515BI0100001408 6 NOS.
284 284 Providing , installation , testing & commissioning of Glass Break Type Manual Call Point BI01010001010000000000000515BI0100001409 6 NOS.
285 285 Supply of following sizes of XLPE insulated Aluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 4CX10 SQMM AL ARMOURD CABLE BI01010001010000000000000515BI0100001410 150 Mtr
286 286 Supply of following sizes of XLPE insulated Aluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 3.5CX35 SQMM AL ARMOURD CABLE BI01010001010000000000000515BI0100001411 100 Mtr
287 287 Supply of following sizes of XLPE insulated Aluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 3.5CX70 SQMM AL ARMOURD CABLE BI01010001010000000000000515BI0100001412 50 Mtr
288 288 Supply of following sizes of XLPE insulated Aluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 3.5CX185 SQMM AL ARMOURD CABLE BI01010001010000000000000515BI0100001413 50 Mtr
289 289 Supply of LED street light fitting not more than 30W having System Efficacy >120 lm/W, system output >3600Lumens, THD <10%, Power Factor >0.95, CRI >70, CCT 5700, Full IP 66 ( with out Glue) protected single piece die cast aluminium housing having toughned glass/PC with Impact resistance IK07. LED driver should be Fully metal body Potted & Encapsulated . BIS compliant driver should sustain 440V Stress Voltage protection for 8 Hrs., High Cut off : 325V(+/- 15V) and should have feature of Auto Restart. Driver shall have 4KV Surge protection and feasibility of 10KV external SPD housed in Luminiare and confirming standard IEC60598. Including suitable size GI pipe bracket clamps, nut, bolts and washers complete all as directed. Make : PHILIPS cat. part no. BRP046 LED 36 CW MR S1 PSU GR or eqivalent as per approved make BI01010001010000000000000515BI0100001414 10 NOS.
290 290 Supply of 5.0 Mtr Height Galvanized Iron OctagonalPoles having uniformly tapered polygonal shape throughout the length with straightLongitudinal welding in a single shaft. There shall not be any circumferential welding. Dimensions:Top Dia.: 70mm, Bottom Dia.: 130mm, Thickness 3mm &Base plate 200*200*12 mm. Dimension of Foundation Bolts - Length 600mm, Dia. 24mm &04 Nos. Bolts manufactured from special steel along with nuts, washer, anchor plates & Templates. SingleArm of 0.5 Mtr. Shall be provided along with – MAKE PHILIPS or eqivalent as pr approved make. BI01010001010000000000000515BI0100001415 10 NOS.
291 291 Safety Equipments & Accessories BI01010001010000000000000515BI0100001416
292 292 Supplying & laying 1.1 kv grade ISI marked synthetic rubber mats as per specifications of chief electrical inspectorate. BI01010001010000000000000515BI0100001417 2 RM
293 293 Supplying & fixing of shock treatment chart printed in hindi and english fitted in wooden frame and glass at front side and hard board at back side. BI01010001010000000000000515BI0100001418 2 Nos
294 294 Supplying & fixing in position 1.1 kv rubber hand gloves. BI01010001010000000000000515BI0100001419 2 Set
295 295 Supplying of first aid box as approved by St. John Ambulance Brigade/Indian Red Cross conforming to IS : 2217 - 1963. BI01010001010000000000000515BI0100001420 2 Nos
296 296 Supplying of Electrical maintenance tool kit as per requirement of chief electrical inspectorate. BI01010001010000000000000515BI0100001421 1 Nos
297 297 SITC of 11 KV, 630 Amp Outdoor type HT RMU. The RMU Should consist on one no of Load break switch (LBS) as incomer and one VCB as outgoing. The RMU should be type tested according to IEC 62271-100, 200 & 102, IAC AFL, 21 kA for 1 sec, IP class 54, IP 67 for Tank. The rated voltage should be 12 kV, impulse withstand voltage of 75 kVp, Power frequency withstand voltage of 28 kV, rated short time current of 21 kA for 3 sec. The RMU should have SF6 gas insulation, robotic welding of gas tank. The RMU should be suitable for outdoo application. The manufacturer should have service centre in the state of uttarakhand. BI01010001010000000000000515BI0100001422 1 Nos
298 298 Supply,Installation, testing & Commissioning of double pole structure suitable for 11 KV HT system as per CEA & UPCL norms & comprising of the following ,but not limited to it for completion of works . RSJ pole of 9 mtrs length of size 175 X 90 mm complete with suitable MS base plate welded at bottom base plate - 2 nos.MS channel of size 100 X 50 mm , length 4 mtrs (approx.)11 KV AB switch - 1 set , 11 KV Horn gap fuse unit - 1 set , 11 KV Lightning Arrestor , 11 KV Disc Insulator , 11 KV pin insulator 6 swg copper wire for jumpering Supply and erection of stay set complete with necessary foundation , excavation, and refilling of earth etc. as required. Concrete foundation for RJS poles burried upto a depth of 1830mm in ground in a pit of size 450 X 450 mm in CC 1:3:6 along with 200 mm copping above ground inclusive of earth work.Necessary Nut , Bolts, Clamps, operating handle for AB switch , clamping welding etc. complete as required. Painting the RSJ poles complete with two coat of red oxide and two coats of GI enamel paints complete as required. BI01010001010000000000000515BI0100001423 1 Sets
299 299 Supply, installation, testing and commissioning of outdoor TYPE, OIL type transformer with copper winding having a continuous rating of 160 kVA, 11kV/415 +/- 1% V, 3 phase, 50 Hz, DY-11 vector group, The transformer shall have cable end box for indoor termination of HT cable on HT side and Cable Box for indoor termination on LT side, complete in all respects including standard accessories. It is To be installed on Top of two pole structure with proper iron angle channel support as required.Compliance to BEE Standards AND BIS Standards (IS 1180). BI01010001010000000000000515BI0100001424 1 Nos
300 300 Supply of HT (UE) AL XLPE Cable of size 3 C X 120 sq mm BI01010001010000000000000515BI0100001425 50 mtrs
301 301 Supply,installation,testing and commissioning of MS C class Heavy duty pipe Inclueding forged fitting such as bends, tees, reducers,welding rods,two cote red oxide peimer and one cote post office red paint,angle,fastnor,two cote black japan etc. as follow ,100 mm line (approx.) C Class BI01010001010000000000000515BI0100001426 50 Mtr.
302 302 Supply,installation,testing and commissioning of MS C class Heavy duty pipe Inclueding forged fitting such as bends, tees, reducers,welding rods,two cote red oxide peimer and one cote post office red paint,angle,fastnor,two cote black japan etc. as follow., 80mm line (approx.) C Class BI01010001010000000000000515BI0100001427 6 Mtr.
303 303 Supply,installation,testing and commissioning of MS C class Heavy duty pipe Inclueding forged fitting such as bends, tees, reducers,welding rods,two cote red oxide peimer and one cote post office red paint,angle,fastnor,two cote black japan etc. as follow ,.25mm line (approx.) C Class BI01010001010000000000000515BI0100001428 12 Mtr.
304 304 SITC of wrapping coating of pipe line in trenches BI01010001010000000000000515BI0100001429 30 Mtr
305 305 Supply,installation, testing and commissioning of single headed landing valve of 63mm dia. Made of SS hydrant valve complete with necessary fitting. BI01010001010000000000000515BI0100001430 1 Nos.
306 306 Supply,installation, testing and commissioning of RRL Hose pipe with 63mm dia. and 15mtr.length with SS male and female couplings. BI01010001010000000000000515BI0100001431 2 Nos.
307 307 Supply,installation, testing and commissioning of 63mm dia. SS short branch pipe nozzle suitable for instantaneous connection to hose coupling as required. BI01010001010000000000000515BI0100001432 1 Nos.
308 308 Supply,installation, testing and commissioning of MS hose box keeping two no.of RRL hose pipe and one no.of short branch pipe. BI01010001010000000000000515BI0100001433 1 Nos.
309 309 Supply,installation, testing and commissioning of two way fire brigade inlet connection suitable for local fire tender complete as required. BI01010001010000000000000515BI0100001434 1 Nos.
310 310 Supply,installation,testing and commissioning of swinging type first aid fire hose reel of 20mm internal dia and 30 mtr long with MS drum and 5mm shut of nozzle complete with fitting complete as required. BI01010001010000000000000515BI0100001435 3 Nos.
311 311 Supply,installation,testing and commissioning of gun matel body air release valve complete with all fitting as equired like ball vlave,holdtite,suta etc. BI01010001010000000000000515BI0100001436 1 Nos.
312 312 Supply,installation,testing and commissioning of Cast Iron body Butterfly Valve complte with all fitting as requied like MS flange, nut bolts,washers etc. 100 mm BI01010001010000000000000515BI0100001437 3 Nos.
313 313 Supply,installation,testing and commissioning of Cast Iron body Non return valve complte with all fitting as requied like MS flange, nut bolts,washers etc. 100 mm BI01010001010000000000000515BI0100001438 2 Nos.
314 314 Supply,installation,testing and commissioning of Pressure Gauge. (0-10kg). Make : H.Guru/Hebig BI01010001010000000000000515BI0100001439 1 Nos.
315 315 16mm x 4core. From pump electric panel to fire pump . BI01010001010000000000000515BI0100001440 40 Mtr.
316 316 Supply,installation,testing and commissioning of gun matel body Ball Valve.25mm dia. BI01010001010000000000000515BI0100001441 5 Nos.
317 317 Supply,installation,testing and commissioning of pressure switch (maximum pressure range 10kg/sq high)for hydrant stand by and jocky pumps, complete as required. BI01010001010000000000000515BI0100001442 1 Nos.
318 318 Supply,installation,testing and commissioning of air vashal tank complete with all fitting like air release valve,ball valve,MS Flanges,holdtite,suta etc.(200mm dia x 2000mm length). BI01010001010000000000000515BI0100001443 1 Nos.
319 319 Supply,installation,testing and commissioning of Terrace tank made of zinc aluminium sheet and plastic lining 10,000 Ltr BI01010001010000000000000515BI0100001444 1 Nos.
320 320 Connection of terrace tank with existing water supply line BI01010001010000000000000515BI0100001445 1 Job
321 321 Supplying,Installatoin,Testing,& Commissioning of Terrace pumps of 450 lpm @ 45 mtr head BI01010001010000000000000515BI0100001446 1 Nos.
322 322 Supply, installation, testing and commissioning of starter for terrace pumps BI01010001010000000000000515BI0100001447 1 Nos.
323 323 RCC Hole Cutting BI01010001010000000000000515BI0100001448 3 Nos.
324 324 Digging of underground line BI01010001010000000000000515BI0100001449 30 Mtr.
325 325 Providing and fixing anti vivration mounting for pipe line,. 100 mm dia BI01010001010000000000000515BI0100001450 1 pc
326 326 Supply and installation of ABC powder stored pressure type portable fire extinguisher ISI marked 15683- 2006 & ISO - 9001, complete as required capacity - 6 kg BI01010001010000000000000515BI0100001451 18 pc
327 327 Supply and installation of CO2 type fire extinguisher ISI marked steel body 15683- 2006 & ISO - 9001, complete as required capacity - 4.5 kg BI01010001010000000000000515BI0100001452 18 pc
328 328 Supply and installation of Mechanical Foam (AFFF) type fire extinguisher ISI marked steel body 15683- 2006 & ISO - 9001, complete as required capacity - 9 ltr BI01010001010000000000000515BI0100001453 3 pc
329 329 Supply,installation of fire Bucket as per IS spacification with stand (holding four bucket). BI01010001010000000000000515BI0100001454 5 set
330 330 Supply, Installation, Testing and Commissioning of 5 HP Electric Driven Fire Pump suitable for auto/maual operation & consisting of following: complete in all respect like pump, motor, coupling etc. BI01010001010000000000000515BI0100001455 2 Set
331 331 Fabrication, Supplying, Installation, Testing & Commissioning of Starter for Pumps BI01010001010000000000000515BI0100001456 2 pc
332 332 SITC of Cable for pump 4cx6 mm Aluminium armoured BI01010001010000000000000515BI0100001457 30 Mtr
333 333 SITC of Foot Valve BI01010001010000000000000515BI0100001458 2 Nos.
334 334 Supply and fixing of GI line of 50 mmdia for pump room BI01010001010000000000000515BI0100001459 12 Mtr
335 335 Supply,installation,testing and commissioning of Cast Iron body Butterfly Valve complte with all fitting as requied like MS flange, nut bolts,washers etc. BI01010001010000000000000515BI0100001460 2 Mtr
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy