}

Supply Of List Of Materials - (I) Rail Pole 60 Kgs 13 Meter (Ii) Rail Pole 52 Kgs 13 Meter (Iii) Rs Joist Pole 9.3 Meter (175X85mm) 19.6 Kgs Per Mtr (Iv) Rs Joist Pole 9 Meter (116X100mm) 23 Kgs Per Mtr (V) 125X70x5 Rs Gi Joist 8Mtr (13.3Kg / Mtr) , JBVNL, Ranchi-Jharkhand

Jharkhand State Electricity Board-JBVNL has published Supply Of List Of Materials - (I) Rail Pole 60 Kgs 13 Meter (Ii) Rail Pole 52 Kgs 13 Meter (Iii) Rs Joist Pole 9.3 Meter (175X85mm) 19.6 Kgs Per Mtr (Iv) Rs Joist Pole 9 Meter (116X100mm) 23 Kgs Per Mtr (V) 125X70x5 Rs Gi Joist 8Mtr (13.3Kg / Mtr) . Submission Date for this Tender is 29-12-2020. Spare Part Tenders in JBVNL, Ranchi Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

26395817
Supply Of List Of Materials - (I) Rail Pole 60 Kgs 13 Meter (Ii) Rail Pole 52 Kgs 13 Meter (Iii) Rs Joist Pole 9.3 Meter (175X85mm) 19.6 Kgs Per Mtr (Iv) Rs Joist Pole 9 Meter (116X100mm) 23 Kgs Per Mtr (V) 125X70x5 Rs Gi Joist 8Mtr (13.3Kg / Mtr)
Open Tender
Indian
Jharkhand
JBVNL, Ranchi
29-12-2020

Tender Details

Supply Of List Of Materials - ( I ) Rail Pole 60 Kgs 13 Meter ( Ii ) Rail Pole 52 Kgs 13 Meter ( Iii ) Rs Joist Pole 9.3 Meter ( 175X85mm ) 19.6 Kgs Per Mtr ( Iv ) Rs Joist Pole 9 Meter ( 116X100mm ) 23 Kgs Per Mtr ( V ) 125X70x5 Rs Gi Joist 8Mtr ( 13.3Kg / Mtr ) ( Vi ) 125X70x6 Rs Gi Joist 5Mtr ( 13.3Kg / Mtr ) ( Vii ) H Beam Pole 11 Meters ( 152X152mm ) 37.1 Kgs Per Mtr ( Viii ) H-Beams 152 X 152 Mm., 37.1 Kg. / Mtr.-13 Mtr. Long = 482.3 Kg ( Ix ) H-Beams 152 X 152 Mm., 37.1 Kg. / Mtr.-9 Mtr. Long= 333.9 Kg ( X ) H-Beams 152 X 152 Mm., 37.1 Kg. / Mtr.-7 Mtr. Long= 259.7 Kg ( Xi ) Psc Pole 400 Kg W.L ( 9 Mtr. ) ( Xii ) Psc Pole 200 Kg W.L ( 8 Mtr. ) ( Xiii ) Steel Tubular Pole ( Sp-28 ) Of 9 Meter ( Xiv ) Steel Tubular Pole ( Sp-55 ) Of 11 Meter ( Xv ) Steel Tubular Pole ( Sp-72 ) Of 13Meter M1629 Acsr Conductors ( I ) Acsr Panther Conductor ( 232 Sq. Mm ) ( Ii ) Acsr Wolf Conductor ( 150 Sq. Mm ) ( Iii ) Acsr Dog Conductor ( 100 Sq. Mm ) ( Iv ) Acsr Racoon Conductor ( 80 Sq. Mm ) ( V ) Acsr Rabbit Conductor ( 55 Mm2 ) ( Vi ) Acsr Weasel Conductor ( 34 Sq. Mm ) M1630 Insulators & H / W Fittings ( I ) 33 Kv Pin Insulator 10 Kn With Pin ( Porcelain Type ) ( Ii ) 33 Kv Polymer Pin Insulators 10 Kn With Gi Pin ( Iii ) 33 Kv Disc Insulator ( Polymer Type ) 90 Kn With H / W Fitting ( Iv ) 33 Kv Disc. Insulator ( Porcelain Type ) 70 Kn With H / W Fitting ( V ) 33 Kv Disc Insulator ( Polymer Type ) 70 Kn With H / W Fitting ( Vi ) Suspension Hardware Suitable For Panther Conductor ( Vii ) Tension Hardware Suitable For Panther Conductor ( Viii ) 11 Kv Pin Insulator 5Kn With Pin ( Porcelain Type ) ( Ix ) 11 Kv Pin Insulator 5 Kn With Pin ( Polymer Type ) ( X ) 11 Kv Disc Insulator ( Polymer Type ) 70 Kn With H / W ( Xi ) 11 Kv Disc Insulator ( Porcelain Type ) 70 Kn With H / W ( Xii ) 11 Kv Disc Insulator ( Porcelain Type ) 45 Kn With H / W ( Xiii ) 11 Kv Disc Insulator ( Polymer Type ) 45 Kn With H / W ( Xiv ) Lt Pin Insulator With Pin ( Porcelain Type ) ( Xv ) Lt Pin Insulator ( Porcelain Type ) ( Xvi ) Lt Pin ( Xvii ) Lt Shackle Insulator ( Porcelain Type ) ( Xviii ) Lt Shackle Strip With Bolts And Nut ( Xix ) 33 Kv Post Insulator 10 Kn ( Polymer ) ( Xx ) 11 Kv Post Insulator 5 Kn ( Polymer ) ( Xxi ) 33 Kv Stay Insulator ( Xxii ) 11 Kv Stay Insulator ( Xxiii ) Lt Stay Insulator ( Xxiv ) Mid Span Compression Joints Suitable For Acsr Panther Conductor ( Xxv ) Repairing Sleeve Suitable For Acsr Panther Conductor M1631 Isolator ( I ) 33 Kv Isolator 800 Amp , 3 Phase, With Earth Switch ( Ii ) 33 Kv Isolator 800 Amp , 3 Phase, With Out Earth Switch ( Iii ) 33 Kv Isolator 600 Amp, 3 Phase, Without Earth Switch ( Iv ) 33 Kv Isolator 600 Amp, 3 Phase, With Earth Switch ( V ) 33 Kv Isolator 400 Amp, 3 Phase, With Earth Switch ( Vi ) 33 Kv Isolator 400 Amp, 3 Phase, Without Earth Switch ( Vii ) 11 Kv Isolator 800 Amp, 3 Phase, With Earth Switch ( Viii ) 11 Kv Isolator 800 Amp, 3 Phase, Without Earth Switch ( Ix ) 12 Kv, 630 A, 25 Ka For 3 Seconds, 3 Phase Double Break Center Rotating Type ( Dbcr ) , Indoor Floor Mounted Motorized Off Load Isolator Panel Along With All Required Accessories Complete ( X ) 11 Kv Isolator 1200 Amp, 3 Phase, With Earth Switch ( Xi ) 11 Kv Isolator 1200 Amp, 3 Phase, Without Earth Switch ( Xii ) 11 Kv Isolator 800 Amp, 3 Phase, With Earth Switch ( Xiii ) 11 Kv Isolator 800 Amp, 3 Phase, Without Earth Switch ( Xiv ) 11 Kv Isolator 600 Amp, 3 Phase, With Earth Switch ( Xv ) 11 Kv Isolator 600 Amp, 3 Phase, Without Earth Switch ( Xvi ) 11 Kv Isolator 400 Amp, 3 Phase, Without Earth Switch ( Xvii ) 11 Kv Isolator 400 Amp, 3 Phase, With Earth Switch ( Xviii ) 11 Kv Isolator 200 Amp Single Phase M1632 Ab Switch ( I ) 33 Kv 3 Pin Type, 3 Phase, Ab Switch 800 Amp ( Porcelain Type ) ( Ii ) 33 Kv 3 Pin Type, 3 Phase, Ab Switch 600 Amp ( Porcelain Type ) ( Iii ) 33 Kv 3 Pin Type, 3 Phase, Ab Switch 600 Amp ( Polymer Type ) ( Iv ) 11 Kv 3 Pin Type, 3 Phase, Ab Switch 800 Amp ( Porcelain Type ) ( V ) 11 Kv 3 Pin Type, 3 Phase, Ab Switch 400 Amp ( Porcelain Type ) ( Vi ) 11 Kv 3 Pin Type, 3 Phase, Ab Switch 400 Amp ( Polymer Type ) ( Vii ) 11Kv Ab Switch 200 Amps ( Single Break ) ( Viii ) 12 Kv, 3-Ph, 200 A, 3 Pin Type, Horizontal Mounting Type, Gang Operated, Ab Switch Along With Support Insulators, Base Channel, Down Pipe, Arcing Horns Etc. Complete As Per Technical Specifications, Scope Of Works And Approved Drawings ( Ix ) 36Kv 630A, 25Ka, 3-Ph, 3 Pin Type, Horizontal Mounting Type , Gang Operated, Ab Switch Along With Support Insulators, Base Channel Down Pipe, Arcing Horns Etc. Complete As Per Technical Specifications, Scope Of Works And Approved Drawings M1633 Lightening Arrestor ( 9Kv 5Ka ) Line Type M1634 Earthing ( I ) 25Mm Dia Ms Rod 3 M Long For Earth Mat ( Ii ) Spike Earthing Made Of 20Mm Gi Solid Rod ( Iii ) G.I Earthing Strip Size 75X8 Mm ( Iv ) G.I Earthing Strip Size 35X3 Mm ( V ) G.I Earthing Strip Size 35X4 Mm ( Vi ) G.I Earthing Strip Size 40X4 Mm ( Vii ) G.I Earthing Strip Size 40X5 Mm ( Viii ) Insulated Gi / Alum.Flexible Wire 16 Sq.Mm ( Ix ) Ace Chemrod ( Artificial Concept Of Earthing By Chemical Rod ) :- Ace Chemrod Earthing Electrode ( Consisting Mild Steel Galvanised Pipe Of Size 2500 Mm In Length X 48 Mm Outer Dia. X 2 Mm Thick, Ms Rod Of Size 2575 Mm X 16 Mm Be Welded With Bottom. The Epoxy Insulator Of Not Less Than 100 Mm Length Is To Be Fixed On Top Of Mild Steel Galvanised Pipe. A Highly Conductive Substance Is To Be Filled In Residual Gap Between Pipe And Rod ) With Highly Conductive Substances Not Less Than 25 Kg For Soil Treatment ( X ) Earthing Complete Conventional Type Having Intermittent Layer Of Charcoal And Salt M1635 Stay Set 1 2 ( I ) Gi Stay Set Complete For D / S / S ( 1900X 16Mm ) With Staywire 7 / 12 Swg And Guy Insulator ( Ii ) Gi Stay Set Complete For D / S / S ( 1900X 20Mm ) With Staywire 7 / 10 Swg And Guy Insulator ( Iii ) 33 Kv Stay Set Complete ( 1900X20 Mm ) With Staywire 7 / 8 Swg And Guy Insulator ( Iv ) Stay Set Complete ( 1800X20mm ) With Stay Wire 7 / 10 Swg & Guy Insulator ( Galvanised ) ( V ) 11 Kv Stay Set Complete ( 1800X16 Mm ) With Stay Wire 7 / 10 Swg And Guy Insulator ( Vi ) Lt Stay Set Complete ( 1700X16 Mm ) With Stay Wire 7 / 12 Swg ( Vii ) Gi Stay Wire No. 7 / 8, 7 / 10, 7 / 12, 7 / 14, 7 / 16 M1636 P.G.Clamps ( I ) P G Clamp For 232 / 150 Sq Mm Conductor ( Ii ) P G Clamp For 80 / 100Mm2 ( Iii ) P G Clamps For 34 / 55Mm2 ( Iv ) Bimettalic Clamps For Distribution Transformers Ht Side ( 25 To 200 Kva ) ( V ) Bimettalic Clamps For Distribution Transformers Ht Side Above ( 200 Kva ) ( Vi ) Bimettalic Clamps For Distribution Transformers Lt Side ( 25 To 200 Kva ) ( Vii ) Bimettalic Clamps For Distribution Transformers Lt Side Above ( 200 Kva ) ( Viii ) Bimettalic Clamps For Power Transformer 5 Mva ( Ix ) Bimettalic Clamps For Power Transformer 10 Mva ( X ) Bimettalic Clamps For Vcbs For 33Kv And 11 Kv ( Xi ) Bimettalic Clamps For Ct Pt Unit ( Xii ) P G Clamp 3 Bolt For Abt Meters M1637 Structures, Gantry Columns And Base Plates ( I ) Structure For 33Kv Lightening Arrestor [ Non-Galvanized ] ( Ii ) Structure For 33Kv Lightening Arrestor [ Galvanized ] ( Iii ) Ms Structure For 33 Kv Isolator ( Iv ) Ms Structure For 11 Kv Isolator ( V ) Structure For 33 Kv Isolator [ Galvanized ] ( Vi ) Structure For 11 Kv Isolator [ Galvanized ] ( Vii ) Ms Structure For 33 Kv Pt ( Non-Galvanised ) ( Viii ) Structure For 33 Kv Pt [ Galvanized ] ( Ix ) Ms Structure For 11 Kv Pt ( Non-Galvanised ) ( X ) Structure For 11 Kv Pt [ Galvanized ] ( Xi ) Ms Structure For Post Insulator For Both 33Kv And 11Kv ( Xii ) Structure For Post Insulator For Both 33Kv [ Galvanized ] ( Xiii ) Structure For Post Insulator For 11Kv [ Galvanized ] ( Xiv ) Ms Structure For 33 Kv Hg Fuse Set ( Non-Galvanised ) ( Xv ) Structure For 33 Kv Hg Fuse Set [ Galvanized ] ( Xvi ) A Swing Bus Structure ( Xvii ) Gantry Column, Girder Structures For 33 / 11 Kv Pss For Single Transformer [ Galvanized ] ( Xviii ) A Structures For Top Mounted Ab Switch On 33 Kv Bus [ Galvanized ] ( Xix ) A Structures For Top Mounted Ab Switch On 11 Kv Bus [ Galvanized ] ( Xx ) A Structures For 11 Kv Take Off With Top Mounted Ab Switch And Provision Of Lightening Arrester [ Galvanized ] ( Xxi ) Gi Base Plate For 33Kv ( 500X500x10 Mm ) Avg Weight 19.6Kg / Plate ( Xxii ) Stone Base Plate For 11 Kv, Dss, Lt M1638 Current And Potential Transformers ( I ) 33 Kv Ct Outdoor Oil Immersed Type, 3 Core, 200-100 / 5-5-1 Amp, Class 0.5 For Differential Protection ( Ii ) 33 Kv Ct Outdoor Oil Immersed Type, 3 Core, 300-150 / 5-5-1 Amp, Class 0.5 For Differential Protection ( Iii ) 33 Kv Ct 800-400 / 5-5A, 2 Core, 15Va , 5P10 For Protection, 10Va, 0.5 Accuracy For Metering 1 2 ( Iv ) 33 Kv Ct 400-200 / 5-5A, 2 Core, 15Va , 5P10 For Protection, 10Va, 0.5 Accuracy For Metering ( V ) 33 Kv Ct 300-150 / 5-5A, 2 Core, 15Va , 5P10 For Protection, 10Va, 0.5 Accuracy For Metering ( Vi ) 33 Kv Ct 200-100 / 5-5A, 2 Core, 15Va , 5P10 For Protection, 10Va, 0.5 Accuracy For Metering ( Vii ) 33 Kv Combined Ct & Pt Unit With Junction Box Complete In All Respect ( Viii ) 11 Kv Ct Outdoor Oil Immersed Type, 3 Core, 600-300 / 5-5-1Amp, Class 0.5 For Differential Protection ( Ix ) 11 Kv Ct 800-400 / 5-5A, 2 Core, 15Va , 5P10 For Protection, 10Va, 0.5 Accuracy For Metering ( X ) 11 Kv Ct 400-200 / 5-5A, 2 Core, 15Va , 5P10 For Protection, 10Va, 0.5 Accuracy For Metering ( Xi ) 11 Kv Ct 300-150 / 5-5A, 2 Core, 15Va , 5P10 For Protection, 10Va, 0.5 Accuracy For Metering ( Xii ) 11 Kv Ct 200-100 / 5-5A, 2 Core, 15Va , 5P10 For Protection, 10Va, 0.5 Accuracy For Metering ( Xiii ) L.T. Ct Ratio 50 / 5A, 5Va, 0.5 Accuracy For Metering, Epoxy Casted ( Xiv ) L.T. Ct Ratio 100 / 5A, 5Va, 0.5 Accuracy For Metering, Epoxy Casted ( Xv ) L.T. Ct Ratio 200 / 5A, 5Va, 0.5 Accuracy For Metering, Epoxy Casted ( Xvi ) L.T. Ct Ratio 300 / 5A, 5Va, 0.5 Accuracy For Metering, Epoxy Casted ( Xvii ) L.T. Ct Ratio 400 / 5A, 5Va, 0.5 Accuracy For Metering, Epoxy Casted ( Xviii ) L.T. Ct Ratio 500 / 5A, 5Va, 0.5 Accuracy For Metering, Epoxy Casted ( Xix ) L.T. Ct Ratio 600 / 5A, 5Va, 0.5 Accuracy For Metering, Epoxy Casted ( Xx ) L.T. Ct Ratio 800 / 5A, 5Va, 0.5 Accuracy For Metering, Epoxy Casted ( Xxi ) 33 Kv / 110V P.T, 50Va, Class 0.5 ( Xxii ) 11 Kv / 110V P.T , 30Va, Class 0.5 ( Xxiii ) 600-400-200 / 5-5-5A ( 0.2S & 5P20 ) Ct& Vcb ( Xxiv ) 600-400-200-100 / 5-5-5-5A ( 0.2S & 5P20 ) Ct& Vcb ( Xxv ) 600-400-200 / 5-5-5A ( 0.5S Ps & 5P20 ) Ct& Vcb ( Xxvi ) 33 / √3 / 110 / √3 / 110 / √3 Pt ( Core 1:0.5S, Core2:3P ) ( Xxvii ) 11 / √3 / 110 / √3 / 110 / √3 Pt ( Core 1:0.5S, Core2:3P ) M1639 Power Transformer ( I ) 33 / 11 Kv Power Transformer 10 Mva Copper Wound, Crgo Core ( Off Load Tap Changer ) ( Ii ) 33 / 11 Kv Power Transformer 10 Mva Copper Wound, Crgo Core ( On Load Tap Changer ) ( Iii ) 33 / 11 Kv Power Transformer 8 Mva Copper Wound, Crgo Core ( Off Load Tap Changer ) ( Iv ) 33 / 11 Kv Power Transformer 05 Mva Copper Wound, Crgo Core ( Off Load Tap Changer ) ( V ) 33 / 11 Kv, 10 / 12.5 Mva, Oil Type, Two Winding, 3 Phase, Dyn11, 50 Hz, Onan / Onaf Transformer With & 8.35% Impedance On 12.5 Mva With Oltc ( Vi ) 33 / 11 Kv Power Transformer 05 Mva Copper Wound, Crgo Core ( On Load Tap Changer ) M1640 Distribution Transformer ( I ) 11 / 0.433 Kv Distribution Transformer 500 Kva, Copper Wound, Crgo M4 Core Onan; Bis Level 2 ( Ii ) 11 / 0.433 Kv Distribution Transformer 200 Kva, Aluminium Winding, Stack Type Crgo Core Fitted, Completely Self Protected; 4 Star - Bee Rating ; Bis Level 2 ( Iii ) Bis Energy Efficiency Level-Ii, 11 / 0.433 Kv100 Kva, Al. Wd., Stack Type Crgo Core, Distribution Transformer Fitted With Lightning Arrester ( La ) And Completely Self–Protected ( Csp ) ( Iv ) 11 / 0.433 Kv Distribution Transformer 100 Kva, Aluminium Winding, Stack Type Crgo Core Fitted; 4 Star - Bee Rating Bis Level 2 ( V ) Bis Energy Efficiency Level-Ii, 11 / 0.433 Kv 63 Kva, Al. Wd., Stack Type Crgo Core, Distribution Transformer Fitted With Lightning Arrester ( La ) And Completely Self–Protected ( Csp ) ( Vi ) 11 / 0.433 Kv Distribution Transformer 63 Kva, Aluminium Winding, Stack Type Crgo Core Fitted; 4 Star - Bee Rating ; Bis Level 2 ( Vii ) Bis Energy Efficiency Level-2 Type Tested, 11 / .433 Kv 25 Kva, Al. Wd., Stack Type Crgo Core, Distribution Transformer Fitted With Lightning Arrester ( La ) And Completely Self –Protected ( Csp ) ( Viii ) 11 / 0.433 Kv Distribution Transformer 25 Kva, Aluminium Winding, Stack Type Crgo Core Fitted; 4 Star - Bee Rating Bis Level 2 ( Ix ) 11 / 0.433 Kv, 500 Kva, Dry Type, Two Winding, 3 Phase, Dyn11, 50 Hz, An, Off Circuit Tap Changer With + / -5% In Steps Of 2.5%On Hv Side For Station Transformer & 4% Impedance With Losses As Per Cbip ( X ) Lighting Transformer Of 415 / 415V, 50 Kva, Dry Type, Two Windin, 3 Phase, Dyn11, 50 Hz With 4% Impedence ( Xi ) 11 / 0.433 Kv Distribution Transformer 25 Kva, Aluminium Winding, Stack Type Crgo Core Fitted; 3 Star - Bee Rating ; Bis Level 1 ( Xii ) 11 / 0.433 Kv Dtr 250Kva Trolley Mounted ( Xiii ) 11 / 0.433 Kv Dtr 250Kva Trolley Mounted M1641 Distribution Box ( I ) Lt Distribution Box Suitable For 500 Kva Transformer ( 800 A, Isolator & 12 Tp Mccb Of 160 A ) ( Ii ) Lt Distribution Box Suitable For 315 Kva Transformer ( 600 A, Isolator & 9 Tp Mccb Of 160 A ) ( Iii ) Lt Distribution Box Suitable For 200 Kva Transformer ( 400 A, Isolator & 6 Tp Mccb Of 120 A ) ( Iv ) Lt Distribution Box Suitable For 100 Kva Transformer ( 200 A, Isolator & 6 Tp Mccb Of 200 A ) ( V ) Ltdb For 200Kva, Isolator 400A, Incoming Mccb 4P, 400A, 50Ka, Outgoing Mccb 3P 100A, 36Ka ( Vi ) Ltdb For 100Kva & 63Kva, Isolator 250A, Incoming Mccb 4P, 200A, 36Ka, Outgoing Mccb 3P 100A, 36Ka ( Vii ) Ltdb For 25Kva, Isolator 63A, Incoming Mccb 4P, 63A, 20Ka, Outgoing Mccb 3P 32A, 20Ka ( Viii ) Lt Distribution Box Suitable For 63 Kva Transformer ( 200 A, Isolator & 6 Tp Mccb Of 100 A ) ( Ix ) Spring Loaded Cp Multi Conn Bus-Bar In Insulated Box Single Phase 1 In 6 Out ( Dist. Box For Fixing On Pole Suitable Ab Xlpe Cable ) ( X ) Spring Loaded Cp Multi Conn Bus-Bar In Insulated Box Single Phase 1 In 9 Out ( Dist. Box For Fixing On Pole Suitable Xlpe Cable ) ( Xi ) Spring Loaded Cp Multi Conn Bus-Bar In Insulated Box Three Phase 1 In 3 Out ( Dist. Box For Fixing On Pole Suitable Ab Xlpe Cable ) ( Xii ) Spring Loaded Cp Multi Conn Bus-Bar In Insulated Box Three Phase 1 In 5 Out ( Dist. Box For Fixing On Pole Suitable Ab Xlpe Cable ) ( Xiii ) Spring Loaded Cp Multi Conn Bus-Bar In Insulated Box Three Phase 1 In 8 Out ( Dist. Box For Fixing On Pole Suitable Ab Xlpe Cable ) ( Xiv ) Spring Loaded Distribution Bus Bar Insulated Box For Fixing On Pole Suitable For Ab Xlpe Cable And Three Phase Connection 1 Incoming And Out Going 3 Phase Connection As Per Field Requirement ( Xv ) Bus Bar ( Aliuminium ) R, Y, B & N Phase Of L.T. Distribution Box For 750 Kva Transformer ( Xvi ) Bus Bar ( Aliuminium ) R, Y, B & N Phase Of L.T. Distribution Box For 500 Kva Transformer ( Xvii ) Bus Bar ( Aliuminium ) R, Y, B & N Phase Of L.T. Distribution Box For 400 Kva Transformer ( Xviii ) Bus Bar ( Aliuminium ) R, Y, B & N Phase Of L.T. Distribution Box For 315 Kva Transformer ( Xix ) Bus Bar ( Aliuminium ) R, Y, B & N Phase Of L.T. Distribution Box For 250 Kva Transformer ( Xx ) Bus Bar ( Aliuminium ) R, Y, B & N Phase Of L.T. Distribution Box For 200 Kva Transformer ( Xxi ) Bus Bar ( Aliuminium ) R, Y, B & N Phase Of L.T. Distribution Box For 100 Kva Transformer ( Xxii ) Bus Bar ( Aliuminium ) R, Y, B & N Phase Of L.T. Distribution Box For 63 Kva Transformer ( Xxiii ) Acb 1250A, 4P, 50Ka ( Xxiv ) Acb 1000A, 4P, 50Ka ( Xxv ) Acb 1250A, 3P, 50Ka ( Xxvi ) Acb 1000A, 3P, 50Ka ( Xxvii ) Mccb 800A, 4P, 36Ka ( Xxviii ) Mccb 700A, 4P, 36Ka ( Xxix ) Mccb 300A, 4P, 36Ka ( Xxx ) Mccb 200A, 4P, 36Ka ( Xxxi ) Mccb 125A, 4P, 36Ka ( Xxxii ) Mccb 100A, 4P, 36Ka ( Xxxiii ) Mccb 63A, 4P, 36Ka ( Xxxiv ) Mccb 800A, 3P, 36Ka ( Xxxv ) Mccb 700A, 3P, 36Ka ( Xxxvi ) Mccb 630A, 3P, 36Ka ( Xxxvii ) Mccb 500A, 3P, 36Ka ( Xxxviii ) Mccb 400A, 3P, 36Ka ( Xxxix ) Mccb 300A, 3P, 36Ka ( Xl ) Mccb 250A, 3P, 36Ka ( Xli ) Mccb 200A, 3P, 36Ka ( Xlii ) Mccb 160A, 3P, 36Ka ( Xliii ) Mccb 125A, 3P, 36Ka ( Xliv ) Mccb 100A, 3P, 36Ka ( Xlv ) Mccb 63A, 3P, 36Ka ( Xlvi ) Mccb Single Pole 200A, 36Ka ( Xlvii ) Mccb Single Pole 160A, 36Ka ( Xlviii ) Mccb Single Pole 120A, 36Ka ( Xlix ) Mccb Single Pole 100A, 36Ka ( L ) Mccb Single Pole 32A, 36Ka ( Li ) Panel Lock M1642 Vcb, C&R Panel ( I ) 33 Kv Vcb, 1250 Amp., Outdoor Type, 26.3 Ka For 1 Sec Rpturing Capacty , With Cr Pannel, & C.T. Ratio 1200-600 / 1-1A, 2 Core, 15Va, 5P10 For Protection, Accuracy 0.5, 10Va For Metering.Pt 33Kv / 110V, Accuracy Class 0.5, Va Burden 50Va, ( Ii ) 33 Kv Vcb, 1250 Amp., Outdoor Type, 26.3 Ka For 1 Sec Rpturing Capacty , With Cr Pannel, & C.T. Ratio 600-300 / 1-1A 400-200 / 1-1A, 2 Core, 15Va, 5P10 For Protection, Accuracy 0.5, 10Va For Metering.Pt 33Kv / 110V, Accuracy Class 0.5, Va Burden 50Va, ( Iii ) 33 Kv Vcb, 800 Amp., Outdoor Type, 16 Ka For 1 Sec Rpturing Capacty , With Cr Pannel, & C.T. Ratio 400-200 / 1-1A Or 200-100 / 1-1A, 2 Core, 15Va, 5P10 For Protection, Accuracy 0.5, 10Va For Metering.Pt 33Kv / 110V, Accuracy Class 0.5, Va Burden 50Va, ( Iv ) 33 Kv Vcb, 1250 Amp., Outdoor Type, 16 Ka For 1 Sec Rpturing Capacty , With Cr Pannel, & C.T. Ratio 600-300 / 1-1A 400-200 / 1-1A, 2 Core, 15Va, 5P10 For Protection, Accuracy 0.5, 10Va For Metering.Pt 33Kv / 110V, Accuracy Class 0.5, Va Burden 50Va, ( V ) 11 Kv Vcb, Outdoor Type, 1250 A, 25 Ka For 3 Sec. Rupturing Capacity Wth C&R Panel.Ct 800-400 / 5-5A, 2 Core, 15Va, 5P10 For Protection, Accuracy 0.5, 10Va For Metering. P.T. 33Kv / 110V, Accuracy Class 0.5, 30 Va ( Vi ) 11 Kv Vcb, Outdoor Type, 630 A, 25 Ka For 3 Sec. Rupturing Capacity Wth C&R Panel.Ct 600-300 / 5-5A Or 400-200 / 5-5A, 2 Core, 15Va, 5P10 For Protection, Accuracy 0.5, 10Va For Metering. P.T. 33Kv / 110V, Accuracy Class 0.5, 30 Va ( Vii ) 11 Kv Vcb, Outdoor Type, 800 A, For Incoming, 18.4 Ka For 1 Sec. Rupturing Capacity With Panel ( Indoor ) 24 V Dc Operated Withct 600-300 / 5-5A Or 400-200 / 5-5A, 2 Core, 15Va, 5P10 For Protection, Accuracy 0.5, 10Va For Metering. P.T. 33Kv / 110V, Accuracy Class 0.5, 30 Va ( Viii ) 11 Kv Vcb, Outdoor Type, 400 A, For Outgoing, 18.4 Ka For 1 Sec. Rupturing Capacity With Panel ( Indoor ) 24 V Dc Operated Withct 600-300 / 5-5A Or 400-200 / 5-5A, 2 Core, 15Va, 5P10 For Protection, Accuracy 0.5, 10Va For Metering. P.T. 33Kv / 110V, Accuracy Class 0.5, 30 Va ( Ix ) 11 Kv Vcb, Outdoor Type, 400 A, For Capacitor, 18.4 Ka For 1 Sec. Rupturing Capacity With Panel ( Indoor ) 24 V Dc Operated Withct 600-300 / 5-5A Or 400-200 / 5-5A, 2 Core, 15Va, 5P10 For Protection, Accuracy 0.5, 10Va For Metering. P.T. 33Kv / 110V, Accuracy Class 0.5, 30 Va ( X ) Indoor Type Control And Relay Panel For 11Kv, 3Phase, 1250 A Vcb ( Transformer Breaker ) Consisting Of A-Meter, Volt-Meter, Relays & Accessories Complete As Per Specifications For Transformer Breaker Protection ( Xi ) Indoor Type Control And Relay Panel For 11 Kv 3 Phase, 1250 A Vcb ( Feeder Breakers ) Consisting Of A-Meter, Volt-Meter, Relays & Accessories Complete For Feeder Breaker Protection As Per Technical Specifications. ( Xii ) Indoor Type Control And Relay Panel For 33Kv, Vcb ( Feeder Breaker ) Consisting Of A-Meter, Volt-Meter, Relays & Accessories Complete. ( Xiii ) Indoor Type Control And Relay Panel For 33Kv, Vcb ( Transformer Breaker ) Consisting Of A-Meter, Volt-Meter, Relays Accessories Complete. ( Xiv ) Indoor Type Control And Relay Panel For 11Kv, Vcb ( Transformer Breaker ) Consisting Of A-Meter, Volt-Meter, Relays Accessories Complete. ( Xv ) Indoor Type Control And Relay Panel For 11Kv, Vcb ( Feeder Breaker ) Consisting Of A-Meter, Volt-Meter, Relays & Accessories Complete. M1643 ( ) Distribution Board ( I ) 415V Ac Power Distribution Board ( Ii ) 30V Dc Distribution Board M1644 ( ) Pipe Connector ( I ) Aluminium Pipe Connector ( Ii ) Connector Pipe To Panther ( Iii ) Connector Panther To Panther ( Iv ) Connector Panther To Ab Switch ( V ) Connector Pipe To Pipe ( Vi ) Connector Pipe To Dog ( Vii ) Connector Pipe To Ab Switch ( Viii ) Connector Dog To Ab Switch M1645 Copper Control Cable ( I ) 2.5 Mm2 Copper 2 Core Control Cable ( Armoured ) ( Ii ) 2.5 Mm2 Copper 2 Core Control Cable ( Unarmoured ) ( Iii ) 2.5 Mm2 Copper 4 Core Control Cable ( Armoured ) ( Iv ) 2.5 Mm2 Copper 4 Core Control Cable ( Unarmoured ) ( V ) 2.5 Mm2 Copper 6 Core Control Cable ( Armoured ) ( Vi ) 2.5 Mm² Copper 6 Core Un-Armourd Cable ( Vii ) 7 Core X 2.5 Sq.Mm. Armoured Control Cable ( Viii ) 2.5 Mm2 Copper 8 Core Control Cable ( Unarmoured ) 1 2 ( Ix ) 2.5 Mm2 Copper 10 Core Control Cable ( Armoured ) ( X ) 2.5 Mm2 Copper 10 Core Control Cable ( Unarmoured ) ( Xi ) 2.5 Mm2 Copper 12 Core Control Cable ( Armoured ) ( Xii ) 2.5 Mm2 Copper 12 Core Control Cable ( Unarmoured ) ( Xiii ) 19 Core X 2.5 Sq.Mm.Armoured Control Cable M1646 Capacitor Bank ( I ) Fully Automatic Capacitor Bank With Automatic Control Panel, Isolator, Indoor Type Suitable Vacuum Circuit Breaker, Mounting Structures Etc As Required As Per Technical Specifications, Drawings, Scope Of The Works Of Following Capacities: ( Banks In Muiltiple Of 600 Kvar As Per Specification ) -3600 Kvar ( Ii ) 1815 Kvar 12.1 Kv 3-Phase 50 Hz Outdoor Type Capacitor Bank Having Step As 363 Kvar+726 Kvar+726 Kvar 12.1 Kv Bank Shall Be Complete With Capacitor Units Of 121 Kvar At 6.98 Kv Including Allied Materials Such As Suitable Size Of Aluminium Busbars, Pin / Pos ( Iii ) Fully Automatic Capacitor Bank With Automatic Control Panel, Isolator, Indoor Type Suitable Vacuum Circuit Breaker, Mounting Structures Etc As Required As Per Technical Specifications, Drawings, Scope Of The Works Of Following Capacities: ( Banks In Muiltiple Of 600 Kvar As Per Specification ) -1200 Kvar ( Iv ) 1089 Kvar 12.1 Kv 3-Phase 50 Hz Outdoor Type Capacitor Bank Having Step As 363 M1647 Metering Equipment ( I ) 33 Kv Metering Cubicle With Pt & Ct , 0.5S Accuracy Class For Ct And 0.5 Accuracy Class For Pt ( Ii ) 33 Kv Outdoor Type Oil Immersed Ct-Pt Combined Metering Unit 0.5S Accuracy Class For Ct And 0.5 Accuracy Class For ( Iii ) 33 Kv, Three Phase Three Wire / Three Phase Four Wire, Accuracy Class 0.2S, Dlms Compliant Abt Meter ( Modular Rack-Mounted ) ( Iv ) 33 Kv, Three Phase Three Wire / Three Phase Four Wire, Accuracy Class 0.2S, Dlms Compliant Abt Meter ( Projection Type ) ( V ) 33 Kv / 110 V, Three Phase Four Wire, ( 0.2S Accuracy Class For Ct And 0.2 Accuracy Class For Pt ) , Ratio- 1600 / 1A Or 1200 / 1A Ct-Pt Combined Metering Unit For Feeder ( Vi ) Metering Panel, Data Concentrator Unit ( Dcu ) With Modem ( Vii ) Structure For 33 Kv Metering Unit ( Viii ) Ht Electronic Trivector Static Meter, 3 Phase 4 Wire, Accuracy Class 0.2S ( – / 110V & – / 5A ) ( Dlms Complaint ) With Compatible Gprs Modem With Meter Box ( Ix ) Ht Electronic Trivector Static Meter, 3 Phase 4 Wire, Accuracy Class 0.5S ( – / 110V & – / 5A ) ( Dlms Complaint ) With Compatible Gprs Modem With Meter Box ( X ) Trivector Energy Meter Of 800 / 5 Amp For 100 Kva Dtr ( Xi ) Trivector Energy Meter Of 400 / 5 Amp ( Xii ) 11 Kv, Outdoor Type Oil Immersed Ct-Pt Combined Metering Unit, 3 Phase 4 Wire ( 11Kv / 110V ) [ 12 Kv Pt 50Va Burden 0.5 Accuracy Class; Ct 20 / 5A, 30 / 5A, 60 / 5A, 100 / 5A, 200 / 5A, 400 / 5A, 15 Va, 0.5 Accuracy Class ] ( Xiii ) 11 Kv Metering Cubicle With Pt Ratio 11Kv / √3 / 110V And Ct Ratio 20 / 5A, 30 / 5A, 60 / 5A, 100 / 5A, 200 / 5A, 400 / 5A, 0.5 Accuracy Class For Both ( Xiv ) Ltct Electronic Meter, Ct Ratio ( 1000 / 5 ) , 3 Phase 4 Wire With Meter Box, Class 0.5S Accuracy ( Xv ) Ltct Electronic Meter ( 200 / 5 ) 3 Phase 4 Wire With Meter Box, Class 0.5S Accuracy ( Xvi ) Ltct Electronic Meter ( 150 / 5 ) 3 Phase 4 Wire With Meter Box, Class 0.5S Accuracy ( Xvii ) Ltct Electronic Meter ( 100 / 5 ) 3 Phase 4 Wire With Meter Box, Class 0.5 Accuracy ( Xviii ) Ac 3 Phase, 4 Wire, 40-200Amp Lt Electronic Trivector Accuracy Class 1.0 Dlms Compliant Category A Meter With Inbuilt Cts And Inbuilt Gsm / Gprs Modem For Di Rating Upto 100 Kva ( Xix ) Structure For D.T Meter ( Xx ) Ac 3 Phase Dtr Meter Complete Set Above 100Kva 400 / 5A ( Xxi ) Lt Electronic Trivector Meter 40-200 Amp. ( Xxii ) 11 Kv / 110, 3 Phase 4 Wire Accuracy Class Dlms Compliant Trivector Energy Meter Ratio 200 / 5A ( Xxiii ) 11 Kv / 110, 3 Phase 4 Wire Accuracy Class Dlms Compliant Trivector Energy Meter Ratio 400 / 5A ( Xxiv ) 11 Kv / 110, 3 Phase 4 Wire Accuracy Class Dlms Compliant Trivector Energy Meter Ratio 600 / 5A ( Xxv ) 33 Kv / 110, 3 Phase 4 Wire Accuracy Class Dlms Compliant Trivector Energy Meter Ratio 400 / 1A ( Xxvi ) 33 Kv / 110, 3 Phase 4 Wire Accuracy Class Dlms Compliant Trivector Energy Meter Ratio 600 / 1A ( Xxvii ) 33Kv / 110V , 3 Phase, 4 Wire , Accuracy Class 0.5 Ct-Pt, Combined Metering Unit For Feeder, Ratio 400 / 1A ( Xxviii ) 11Kv / 110, 3 Phase, 4 Wire , Accuracy Class 0.5 Ct-Pt, Combined Metering Unit For Feeder, Ratio 400 / 5A ( Xxix ) 11 Kv / 110 V 3 Phase 4 Wire Accuracty Class 0.5 Ct-Pt Combined Metering Unit For Feeder, Ratio 200 / 5 A ( Xxx ) 33Kv / 110V , 3 Phase, 4 Wire , Accuracy Class 0.5 Ct-Pt, Combined Metering Unit For Feeder, Ratio 600 / 1A ( Xxxi ) 11 Kv / 110, 3 Phase 4 Wire Accuracty Class 0.5 Ct-Pt Combined Metering Unit For Feeder, Ratio 600 / 5 A ( Xxxii ) Dlms Compliant, Single Phase 2 Wire 5-30 Amp. 1.0 Accuracy, Class-Ac Statics Single Phase Meter With Meter Box ( Xxxiii ) Lt Static Energy Meter, 3 Phase 4 Wire, Direct Connected, 100 Amp. With Meter Box, Class 1.0 Accuracy ( Xxxiv ) Three Phase 4 - Wire Ac Static Whole Current Meter, Electronic Energy Meter With Box ( 10-60 ) Amp 1 2 ( Xxxv ) Single Phase Electronic Meter, Two Wire, 5-30 Amp. Class 1.0 Accuracy With Box ( Xxxvi ) Single Phase Rf Meter With Box As Per Is 13779 Standards, Dlms Compliant ( Xxxvii ) Three Phase Rf Meter With Box As Per Is 13779 Standards, Dlms Compliant ( Xxxviii ) Single Phase Rs 232 / 485 Prepaid Energy Meter ( Xxxix ) Three Phase Rs 232 / 485 Prepaid Energy Meter ( Xl ) Single Phase Rf Prepaid Energy Meter ( Xli ) Three Phase Rf Prepaid Energy Meter ( Xlii ) Single Phase Gprs / Gsm Prepaid Energy Meter ( Xliii ) Three Phase Gprs / Gsm Prepaid Energy Meter ( Xliv ) Supply Of L.T. Meter Boxes ( Metering Cubicle ) With L.T Cts Of Different Ratio, Class Of Accuracy 0.5 Along With Pvc Wire For Connection Of Metering. ( Xlv ) L.T C.T. Resin Casted Having Ratio 100 / 5A Class Of Accuracy 0.5 ( Xlvi ) L.T C.T. Resin Casted Having Ratio 150 / 5A Class Of Accuracy 0.5 ( Xlvii ) L.T C.T. Resin Casted Having Ratio 200 / 5A Class Of Accuracy 0.5 ( Xlviii ) L.T C.T. Resin Casted Having Ratio 300 / 5A Class Of Accuracy 0.5 ( Xlix ) L.T C.T. Resin Casted Having Ratio 400 / 5A Class Of Accuracy 0.5 ( L ) L.T C.T. Resin Casted Having Ratio 600 / 5A Class Of Accuracy 0.5 ( Li ) L.T C.T. Resin Casted Having Ratio 800 / 5A Class Of Accuracy 0.5 ( Lii ) L.T C.T. Resin Casted Having Ratio 1000 / 5A Class Of Accuracy 0.5 ( Liii ) Pvc Cable Gland Sizes 20 Mm, ( Liv ) Pvc Cable Gland Sizes 25 Mm, ( Lv ) Pvc Cable Gland Sizes 32 Mm ( Lvi ) Pvc Cable Gland Sizes 40 Mm ( Lvii ) Pvc Cable Gland Sizes 50 Mm ( Lviii ) Pvc Cable Gland Sizes 63 Mm ( Lix ) Pvc Cable Gland Sizes 75 Mm M1648 Gi Service Pipe ( I ) Gi Service Pipe 25 Mm Diameter 3 Mtr Length ( Ii ) Gi Service Pipe 40 Mm Diameter 3 Mtr Length ( Iii ) Gi Service Pipe 60Mm Diameter 3 Mtr Length ( Iv ) G.I. Pipe 3 Dia M1649 Ring Main Units ( I ) 11 Kv 3 Way Rmu, 2Od + 1Vl, One Incomer + One Breaker + One Outgoing ( Ii ) 11 Kv 4 Way Rmu, 2Od + 2Vl, ( One Incomer + Two Breakers + One Outgoing ( Iii ) 11 Kv 5 Way Rmu, 2Od + 3Vl, ( One Incomer + Three Breakers + One Outgoing ) ( Iv ) 11 Kv 6 Way Rmu, 2Od + 4Vl, ( One Incomer + Four Breakers + One Outgoing M1650 Xlpe Insulated Cables ( I ) 33 Kv Ht Xlpe Cable Single Core 630Mm2 ( Armoured ) ( Ii ) 1C X 400Mm2 Cable ( 33 Kv Power Cable ) ( Iii ) 33 Kv Ht Xlpe Cable 3 Core 400 Sq Mm ( Armoured ) ( Iv ) 33 Kv Ht Xlpe Cable 3 Core 300Mm2 ( Armoured ) ( V ) 33 Kv Ht Xlpe Cable 3 Core 240Mm2 ( Armoured ) ( Vi ) 33 Kv Ht Xlpe Cable 3 Core 185Mm2 ( Armoured ) ( Vii ) 33 Kv Ht Xlpe Cable 3 Core 150Mm2 ( Armoured ) ( Viii ) 33 Kv Ht Xlpe Cable 3 Core 120Mm2 ( Armoured ) ( Ix ) 33 Kv Ht Xlpe Cable 3 Core 95Mm2 ( Armoured ) ( X ) 33 Kv Ht Xlpe Cable 3 Core 70Mm2 ( Armoured ) ( Xi ) 33 Kv Ht Xlpe Cable 3 Core 50Mm2 ( Armoured ) 1 2 ( Xii ) 3Core X 35 Sq. Mm Cable ( Xiii ) 11 Kv Xlpe Cable Single Core 630Mm2 ( Armoured ) ( Xiv ) 11 Kv Xlpe Cable Single Core 120Mm2 ( Armoured ) ( Xv ) 11 Kv Xlpe Cable Single Core 70Mm2 ( Armoured ) ( Xvi ) 11 Kv Xlpe Cable Single Core 50Mm2 ( Armoured ) ( Xvii ) 11 Kv Xlpe Cable Single Core 35Mm2 ( Armoured ) ( Xviii ) 3Core X 630Sq Mm ( 11 Kv Power Cable ) ( Xix ) 11 Kv Xlpe Cable 3 Core 25Mm2 ( Armoured ) ( Xx ) Power Cable For Dt Meter 120 Sq.Mm Unarmoured ( Xxi ) Power Cable For Dt Meter 240 Sq.Mm Unarmoured ( Xxii ) Power Cable 240 Sq. Mm. ( Unarmoured ) ( Xxiii ) Xlpe Cable 4 Core 16 Mm2 ( Xxiv ) Lt Xlpe Cable 4 Core 16Mm2 ( Unarmoured ) ( Xxv ) Lt Xlpe Cable 4 Core 25Mm2 ( Armoured ) ( Xxvi ) Lt Xlpe Cable 3.5 Core 300Mm2 ( Armoured ) ( Xxvii ) Lt Xlpe Cable 3.5 Core 185Mm2 ( Armoured ) ( Xxviii ) Lt Xlpe Cable 3.5 Core 120Mm2 ( Armoured ) ( Xxix ) Lt Xlpe Cable 3.5 Core 95 Mm2 ( Armoured ) ( Xxx ) Lt Xlpe Cable 3.5 Core 50Mm2 ( Armoured ) ( Xxxi ) Lt Xlpe Cable 3.5 Core 25Mm2 ( Armoured ) ( Xxxii ) Lt Xlpe Cable 2 Core 10Mm2 ( Armoured ) ( Xxxiii ) Lt Xlpe Cable 2 Core 6Mm2 ( Armoured ) ( Xxxiv ) Lt Xlpe Cable 1Cx120 Sqmm ( Xxxv ) Lt Xlpe Single Core Cable 95 Mm2 ( Armoured ) ( Xxxvi ) Lt Xlpe Single Core Cable 50 Mm2 ( Armoured ) ( Xxxvii ) Lt Xlpe Single Core Cable 25 Mm2 ( Armoured ) ( Xxxviii ) Lt Xlpe Cable 3.5 Core 35 Sq. Mm. ( Armoured ) ( Xxxix ) Lt Xlpe Cable 3.5 Core 70 Sq. Mm. ( Armoured ) ( Xl ) Lt Xlpe Single Core 1100 V Cable 1*35 Sqmm ( Xli ) Lt Xlpe Single Core Unarmoured 1 X 35Sqmm ( Xlii ) Lt Xlpe Single Core Unarmoured 1 X 50 Sqmm ( Xliii ) Lt Xlpe Single Core Unarmoured 1 X 240 Sqmm ( Xliv ) Lt Xlpe Single Core Unarmoured 1 X 400 Sqmm ( Xlv ) Cable 2.5 Core X 240 Sq Mm ( Xlvi ) Lt Xlpe Single Core Unarmoured 1 X 70 Sqmm ( Xlvii ) Cable 2 Core X 16Sq Mm M1651 Pvc Insulated Cables ( I ) 10 Core 2.5 Sqmm Armoured, Stranded Copper Conductor, Pvc Insulated And Pvc Sheathed Cable ( Ii ) 6 Core 2.5 Sqmm Armoured, Stranded Copper Conductor, Pvc Insulated And Pvc Sheathed Cable ( Iii ) 3.5 Core 300 Sq. Mm Armoured, Stranded Aluminium Conductor, Pvc Insulated And Pvc Sheathed Cable ( Iv ) 3.5 Core 240 Sq. Mm Armoured, Stranded Aluminium Conductor, Pvc Insulated And Pvc Sheathed Cable ( V ) 3.5 Core 185 Sq. Mm Armoured, Stranded Aluminium Conductor, Pvc Insulated And Pvc Sheathed Cable ( Vi ) 3.5 Core 150 Sq. Mm Armoured, Stranded Aluminium Conductor, Pvc Insulated And Pvc Sheathed Cable ( Vii ) 3.5 Core 70 Sq. Mm Armoured, Stranded Aluminium Conductor, Pvc Insulated And Pvc Sheathed Cable ( Viii ) 3.5 Core 35 Sq. Mm Armoured, Stranded Aluminium Conductor, Pvc Insulated And Pvc Sheathed Cable ( Ix ) 2 Core 16 Sq. Mm Armoured, Stranded Aluminium Conductor, Pvc Insulated And Pvc Sheathed Cable 1 2 ( X ) 2 Core 2.5 Sqmm Armoured, Stranded Copper Conductor, Pvc Insulated And Pvc Sheathed Cable ( Xi ) 1 Core 50 Sq. Mm Unarmoured, Stranded Aluminium Conductor, Pvc Insulated And Pvc Sheathed Cable ( Xii ) 1 Core 70 Sq. Mm Unarmoured, Stranded Aluminium Conductor, Pvc Insulated And Pvc Sheathed Cable ( Xiii ) 1 Core 120 Sq. Mm Unarmoured, Stranded Aluminium Conductor, Pvc Insulated And Pvc Sheathed Cable ( Xiv ) Lt Pvc Cable 3.5 Core 95 Mm2 ( Armoured ) ( Xv ) Lt Pvc Cable 3.5 Core 10 Mm2 ( Armoured ) ( Xvi ) Lt Pvc Cable 3.5 Core 6 Mm2 ( Armoured ) ( Xvii ) Lt Pvc Cable 2 Core 16 Mm2 ( Armoured ) ( Xviii ) Lt Pvc Cable 2 Core 10 Mm2 ( Armoured ) ( Xix ) Lt Pvc Cable 2 Core 6 Mm2 ( Armoured ) ( Xx ) Lt Pvc Cable 2 Core 4 Mm2 ( Armoured ) ( Xxi ) Lt Pvc Cable 1 Core 16 Mm2 ( Armoured ) ( Xxii ) Lt Pvc Cable 1 Core 50 Mm2 ( Armoured ) ( Xxiii ) Lt Pvc Cable 1 Core 70 Mm2 ( Armoured ) ( Xxiv ) Lt Pvc Cable 1 Core 150 Mm2 ( Armoured ) ( Xxv ) Lt Pvc Cable 1 Core 300 Mm2 ( Armoured ) ( Xxvi ) Pvc Single Phase Service Cable 3.5 Core 25 Mm2 ( Amoured ) ( Xxvii ) 2.5 Sq Mm Twin Core Pvc Service Cable ( Xxviii ) 4 Sq Mm Twin Core Pvc Service Cable ( Xxix ) Pvc Single Phase Service Cable 2 Core 6 Mm2 ( Armoured ) ( Xxx ) Pvc Single Phase Service Cable 2 Core 10 Mm2 ( Armoured ) ( Xxxi ) Pvc Single Phase Service Cable 2 Core 2.5 Mm2 ( Unamoured ) ( Xxxii ) Pvc Single Phase Service Cable 2 Core 4 Mm2 ( Unarmoured ) ( Xxxiii ) Pvc Single Phase Service Cable 2 Core 6 Mm2 ( Unarmoured ) ( Xxxiv ) Pvc Three Phase Service Cable 4 Core 6 Mm2 ( Armoured ) ( Xxxv ) Pvc Three Phase Service Cable 4 Core 8 Mm2 ( Armoured ) ( Xxxvi ) Pvc Three Phase Service Cable 4 Core 10 Mm2 ( Armoured ) ( Xxxvii ) Pvc Three Phase Service Cable 4 Core 16 Mm2 ( Armoured ) ( Xxxviii ) Pvc Three Phase Service Cable 4 Core 25 Mm2 ( Armoured ) ( Xxxix ) Pvc Three Phase Service Cable 4 Core 10 Mm2 ( Unarmoured ) M1652 Aerial Bunched Cables ( I ) 33 Kv Xlpe Ht Ab Cable 3 Core X 185Mm2+240 Mm2 Bare Messenger ( Ii ) 33 Kv Xlpe Ht Ab Cable 3 Core X 120Mm2+150 Mm2 Bare Messenger ( Iii ) 33 Kv Xlpe Ht Ab Cable 3 Core X 95Mm2+120 Mm2 Bare Messenger ( Iv ) 11 Kv Xlpe Ht Ab Cable 3Cx185mm2+240Mm2 Bare Messenger ( V ) 11 Kv Xlpe Ht Ab Cable 3Cx185mm2+150Mm2 Bare Messenger ( Vi ) 11 Kv Xlpe Ht Ab Cable 3Cx150mm2+120Mm2 Bare Messenger ( Vii ) 11Kv Xlpe Ht Ab Cable 3Cx120 Mm2 + 95Mm2 Bare Messenger ( Viii ) 11 Kv Xlpe Ht Ab Cable 3Cx95mm2+80Mm2 Bare Messenger ( Ix ) 11 Kv Xlpe Ht Ab Cable 3Cx70mm2+70Mm2 Bare Messenger ( X ) 11 Kv Xlpe Ht Ab Cable 3Cx50mm2+70Mm2 Bare Messenger ( Xi ) 11 Kv Xlpe Ht Ab Cable 3Cx35mm2+70Mm2 Bare Messenger ( Xii ) 11 Kv Xlpe Ht Ab Cable 3Cx35mm2+35Mm2 Bare Messenger ( Xiii ) Lt Xlpe Ab Cable 3Cx120+1Cx70+1Cx16 Mm2 ( Xiv ) Lt Xlpe Ab Cable 3Cx95 Sqmm + 1X70 Sqmm+1X70 Sq Mm ( Xv ) Lt Xlpe Ab Cable 3Cx95+1Cx70+1Cx16 Mm2 ( Xvi ) Lt Xlpe Ab Cable 3X70+1X50+1X16 ( Street Light ) Mm2 ( Xvii ) Lt Xlpe Ab Cable 3Cx50 Sqmm + 1X35 Sqmm+1X16 Sq Mm ( Xviii ) Lt Xlpe Ab Cable 3X50+1X25+1X35 Mm2 ( Xix ) Lt Xlpe Ab Cables 1X16 ( Ph ) + 1X25 ( Bare Condustor + 1X16 ( Insulated Street Lighting ) Mm2 ( Xx ) Lt Xlpe Ab Cable 3Cx120+70Mm2 ( Xxi ) Lt Xlpe Ab Cable 3Cx95+70Mm2 ( Xxii ) Lt Xlpe Ab Cable 3Cx50+35Mm2 ( Xxiii ) Lt Xlpe Ab Cable 3Cx35+25Mm2 ( Xxiv ) Lt Xlpe Ab Cable 3Cx25+25Mm2 ( Xxv ) Lt Xlpe Ab Cable 3Cx16+25Mm2 ( Xxvi ) Lt Xlpe Ab Cable 1Cx16+25Mm2 Single Phase ( Xxvii ) Lt Xlpe Ab Cable 1Cx35mm2 ( Xxviii ) Lt Xlpe Ab Cable 1Cx250mm2 ( Xxix ) Lt Xlpe Ab Cable 1Cx70mm2 ( Xxx ) Lt Xlpe Ab Cable 1Cx400mm2 M1653 Ab Cable Accessories ( I ) 33 Kv Ab Cable Straight Thru Joint Kit Suitable For 35-70 Sqmm ( Ii ) 33 Kv Ab Cable Straight Thru Joint Kit Suitable For 95-120 Sqmm ( Iii ) 33 Kv Ab Cable Straight Thru Joint Kit Suitable For 185 Sqmm ( Iv ) 33 Kv Abc Termination Kit 95-120 Sqmm ( V ) 33 Kv Abc Termination Kit 185 Sqmm ( Vi ) 33 Kv Abc Termination Kit 240 Sqmm ( Vii ) 11 Kv Ab Cable Straight Thru Joint Kit Suitable For 35-70 Sqmm ( Viii ) 11 Kv Ab Cable Straight Thru Joint Kit Suitable For 95-120 Sqmm ( Ix ) 11 Kv Abc Termination Kit 35-70 Sqmm ( X ) 11 Kv Abc Termination Kit 95-120 Sqmm ( Xi ) Lt Pre Insulated Mid Span Joint Suitable 25 Mm2 Phases ( Xii ) Lt Pre Insulated Mid Span Joint Suitable 35 Mm2 Phases ( Xiii ) Lt Pre Insulated Mid Span Joint Suitable 50 Mm2 Phases ( Xiv ) Lt Pre Insulated Mid Span Joint Suitable 70 Mm2 Phases ( Xv ) Lt Pre Insulated Mid Span Joint Suitable 95 Mm2 Phases ( Xvi ) Lt Pre Insulated Mid Span Joint Suitable 120 Mm2 Phases ( Xvii ) Pre Insulated Mid Span Joint Suitable For 25 Mm2 Neutral Messenger ( Xviii ) Pre Insulated Mid Span Joint Suitable For 35 Mm2 Neutral Messenger ( Xix ) Pre Insulated Mid Span Joint Suitable For 50 Mm2 Neutral Messenger ( Xx ) Insulation Piercing Connector For Db Charging ( Xxi ) Insulation Piercing Connector Branching Suitable For T Joints ( Xxii ) Piercing Connector For Lt Ab Cable ( Xxiii ) Insulation Piercing Connector-Type-I ( Main 16-95 Mm2 & Tap 4-35 Mm2 ) ( Xxiv ) Insulation Piercing Connector-Type-Ii ( Main 16-95 Mm2 & Tap 16-95 Sq Mm ) ( Xxv ) Satellite Connector ( Xxvi ) Lt Ab Cable Accessory, 1.1Mtr. Stainless Steel Strap If207 ( 20X0.7 ) ( Xxvii ) Buckle For Strap ( Xxviii ) Suspension Clamp With Eyehook ( Xxix ) Suspension Clamp Suitable For 25 -70 Sqmm Baremessenger ( Including 1 No. Suspension Clamp With Bracket + 1.5 Mtr Ss Strap + 2 Nos. Ss Buckle ) ( Xxx ) Suspension Clamp Suitable For 35 -95 Sqmm Bare Messenger ( Including 1 No. Suspension Clamp With Bracket + 1.5 Mtr Ss Strap + 2 Nos. Ss Buckle ) 1 2 ( Xxxi ) Suspension Clamp Suitable For 95 -150 Sqmm Bare Messenger ( Including 1 No. Suspension Clamp With Bracket + 1.5 Mtr Ss Strap + 2 Nos. Ss Buckle ) ( Xxxii ) Dead End Clamp With Eyehook ( Xxxiii ) Dead End Clamp Suitable For 25 -50 Sqmm Bare Messenger ( Including 1 No. Dead End Bracket + 1 No. Dead End 1.5 Mtr Ss Strap + 2 Nos. Ss Buckle ) ( Xxxiv ) Dead End Clamp Suitable For 70 -95 Sqmm Bare Messenger ( Including 1 No. Dead End Bracket + 1 No. Dead End 1.5 Mtr Ss Strap + 2 Nos. Ss Buckle ) ( Xxxv ) Dead End Clamp Suitable For 95 -150 Sqmm Bare Messenger ( Including 1 No. Dead End Bracket + 1 No. Dead End 1.5 Mtr Ss Strap + 2 Nos. Ss Buckle ) ( Xxxvi ) Dead End Clamp Assembly Suitable Upto 25 Sq.Mm Bare Messenger ( 01 Dead End Clamp With Bracket, 2 Mtr. Stainless Steel Straps, 02 Nos. Buckles ) ( Xxxvii ) Suspension Clamp Assembly Suitable For 95 Mm2 Bare Messenger ( 01 Nos. Suspension Clamp With Bracket, 2 Mtr. Stainless Stell Straps 02 Nos. Buckles ( Xxxviii ) Service Main Anchor Clamp For Proper Support Of Service Cable ( 4Mm2 And 10 Mm2 ) ( Xxxix ) Eye Hook ( Xl ) Stainless Steel Strip Of 20Mmx1mmx1000mm With Buckle Clip M1654 Fabricated Items ( I ) Hot Dip Galvanized Fabricated Iron Material For 33 Kv Line, Lt Line & Dss ( Ii ) 33 Kv Pole Top Bracket 50X10 Mm Flat [ Galvanized ] ( Iii ) 33 Kv Pole Top Bracket [ Non Galvanized ] ( Iv ) 11Kv Pole Top Bracket 50X8 Mm Flat [ Galvanized ] ( V ) 11 Kv Pole Top Bracket 50X8 Mm ( F- Type ) [ Non Galvanized ] ( Vi ) 11 Kv F Clamp / Bracket ( Vii ) 11 Kv Fish Plate ( Viii ) 33 Kv Fish Plate ( For St Pole 13 Mtr. ) ( Ix ) 33Kv V Cross Arm For ( 100X50x6 Mm ) [ Galvanized ] ( X ) 33 Kv V Cross Arm ( 100X 50X 6 Mm ) [ Non Galvanized ] ( Xi ) 33 Kv Dp Special Type V Cross Arm ( Xii ) 11Kv V Cross Arm ( 75X40x6 Mm ) , 7.14 Kg Per Meter [ Galvanized ] ( Xiii ) 11 Kv V Cross Arm ( 75 X 40 X6 Mm ) [ Non Galvanized ] ( Xiv ) 11 Kv Guarding Channel ( 75X40x6 Mm ) ( Xv ) 33 Kv Guarding Channel ( 100X50x6mm ) ( Xvi ) Ms Angle ( 65X65x6 Mm ) For Guarding Of 33 Kv, 11 Kv, L.T Line [ Galvanized ] ( Xvii ) Ms Angle ( 65X65x6 Mm ) For Guarding Of 33 Kv, 11 Kv, L.T Line [ Non Galvanized ] ( Xviii ) Top Channel Set ( 100X50x6 Mm ) 9.56 Kg Per Meter [ Galvanized ] ( Xix ) Top Channel Set ( 100X50x6 Mm ) 9.56 Kg Per Meter [ Non Galvanized ] ( Xx ) Ms Channel For Ab Switch ( 100X50x6 Mm ) [ Galvanized ] ( Xxi ) Ms Channel Ab Switch ( 100X50x6 Mm ) [ Non Galvanized ] ( Xxii ) 33Kv D P Channel ( 100X50x6 Mm ) 3150 Mm Long [ Galvanized ] ( Xxiii ) 33Kv D P Channel ( 100X50x6 Mm ) 2200 Mm Long [ Galvanized ] ( Xxiv ) 33Kv D P Channel ( 100X50x6 Mm ) 1.3 Meter Long [ Galvanized ] ( Xxv ) 33 Kv D.P Channel ( 100X50x6 Mm ) 1.3 Meter [ Non Galvanized ] ( Xxvi ) 11Kv D P Channel ( 75X40x6 Mm ) [ Galvanized ] ( Xxvii ) 11Kv D.P Channel ( 75X40x6mm ) [ Non Galvanized ] ( Xxviii ) Transformer Base Channel ( 100X50x6 Mm ) [ Galvanized ] ( Xxix ) Transformer Base Channel ( 100X50x6 Mm ) [ Non Galvanized ] ( Xxx ) Transformer Belting ( 50X50x6 Mm ) & Belting Support ( 40X40x6 Mm ) [ Galvanized ] ( Xxxi ) Transformer Belting ( 50X50x6 Mm ) & Belting Support ( 40X40x6 Mm ) [ Non Galvanized ] ( Xxxii ) Back Clamp ( 50X6 Mm ) For 60Kg Rail Pole [ Galvanized ] ( Xxxiii ) Back Clamp ( 50X6 Mm ) For 60Kg Rail Pole [ Non Galvanized ] ( Xxxiv ) Back Clamp ( 50X6 Mm ) For9 Mtr 400Kg Psc Pole [ Galvanized ] ( Xxxv ) Back Clamp ( 50X6 Mm ) For 9Mtr 400Kg Psc Pole [ Non Galvanized ] ( Xxxvi ) Back Clamp ( 50X6 Mm ) For 8 Mtr 200Kg Psc Pole [ Galvanized ] ( Xxxvii ) Back Clamp ( 50X6 Mm ) For 8 Mtr 200Kg Psc Pole [ Non Galvanized ] ( Xxxviii ) Back Clamp ( 50X6 Mm ) For Tublar Pole [ Galvanized ] ( Xxxix ) Back Clamp ( 50X6 Mm ) For Tublar Pole [ Non Galvanized ] ( Xl ) Support Clamp For V Cross Arm For 60Kg Rail Pole [ Galvanized ] ( Xli ) Support Clamp For V Cross Arm For 60Kg Rail Pole [ Non Galvanized ] ( Xlii ) Support Clamp For V Cross Arm For 9 Mtr 400Kg Psc Pole [ Galvanized ] ( Xliii ) Support Clamp For V Cross Arm For 9 Mtr 400Kg Psc Pole [ Non Galvanized ] ( Xliv ) Support Clamp For V Cross Arm For 8 Mtr 200Kg Psc Pole [ Galvanized ] ( Xlv ) Support Clamp For V Cross Arm For 8 Mtr 200Kg Psc Pole [ Non Galvanized ] ( Xlvi ) Support Clamp For V Cross Arm For Tublar Pole [ Galvanized ] ( Xlvii ) Support Clamp For V Cross Arm For Tublar Pole [ Non Galvanized ] ( Xlviii ) Back Clamp For 33 Kv Dp Special Type V Cross Arm ( Xlix ) Back Clamp ( 50X6 Mm ) Jointing / Packing Piece For 60Kg Rail Pole [ Galvanized ] ( L ) Back Clamp ( 50X6 Mm ) Jointing / Packing Piece For 60Kg Rail Pole [ Non Galvanized ] ( Li ) Back Clamp ( 50X6 Mm ) Jointing / Packing Piece For 9 Mtr 400Kg Psc Pole [ Galvanized ] ( Lii ) Back Clamp ( 50X6 Mm ) Jointing / Packing Piece For 9 Mtr 400Kg Psc Pole [ Non Galvanized ] ( Liii ) Back Clamp ( 50X6 Mm ) Jointing / Packing Piece For 8 Mtr 200Kg Psc Pole [ Galvanized ] ( Liv ) Back Clamp ( 50X6 Mm ) Jointing / Packing Piece For 8 Mtr 200Kg Psc Pole [ Non Galvanized ] ( Lv ) Back Clamp ( 50X6 Mm ) Jointing / Packing Piece For Tublar Pole [ Galvanized ] ( Lvi ) Back Clamp ( 50X6 Mm ) Jointing / Packing Piece For Tublar Pole [ Non Galvanized ] ( Lvii ) Clamp For Top Channel 50X6 Mm Flat For 60Kg Rail Pole [ Galvanized ] ( Lviii ) Clamp For Top Channel 50X6 Mm Flat For 60Kg Rail Pole [ Non Galvanized ] ( Lix ) Clamp For Top Channel 50X6 Mm Flat For 9 Mtr 400Kg Psc Pole [ Galvanized ] ( Lx ) Clamp For Top Channel 50X6 Mm Flat For 9 Mtr 400Kg Psc Pole [ Non Galvanized ] ( Lxi ) Clamp For Top Channel 50X6 Mm Flat For 8 Mtr 200Kg Psc Pole [ Galvanized ] ( Lxii ) Clamp For Top Channel 50X6 Mm Flat For 8 Mtr 200Kg Psc Pole [ Non Galvanized ] ( Lxiii ) Clamp For Top Channel 50X6 Mm Flat For Tublar Pole [ Galvanized ] ( Lxiv ) Clamp For Top Channel 50X6 Mm Flat For Tublar Pole [ Non Galvanized ] ( Lxv ) Clamp For Ab Switch Base Channel ( 50X6 Mm ) ( 1 Set For 2 Pair ) For 60Kg Rail Pole [ Galvanized ] ( Lxvi ) Clamp For Ab Switch Base Channel ( 50X6 Mm ) ( 1 Set For 2 Pair ) For 60Kg Rail Pole [ Non Galvanized ] ( Lxvii ) Clamp For Ab Switch Base Channel ( 50X6 Mm ) ( 1 Set For 2 Pair ) For 9 Mtr 400Kg Psc Pole [ Galvanized ] ( Lxviii ) Clamp For Ab Switch Base Channel ( 50X6 Mm ) ( 1 Set For 2 Pair ) For 9 Mtr 400Kg Psc Pole [ Non Galvanized ] ( Lxix ) Clamp For Ab Switch Base Channel ( 50X6 Mm ) ( 1 Set For 2 Pair ) For 8 Mtr 200Kg Psc Pole [ Galvanized ] ( Lxx ) Clamp For Ab Switch Base Channel ( 50X6 Mm ) ( 1 Set For 2 Pair ) For 8 Mtr 200Kg Psc Pole [ Non Galvanized ] ( Lxxi ) Clamp For Ab Switch Base Channel ( 50X6 Mm ) ( 1 Set For 2 Pair ) For Tublar Pole [ Galvanized ] ( Lxxii ) Clamp For Ab Switch Base Channel ( 50X6 Mm ) ( 1 Set For 2 Pair ) For Tublar Pole [ Non Galvanized ] ( Lxxiii ) Ms Channel ( 75X40x6 Mm ) For Supporting H.G Fuse & L.A [ Galvanized ] ( Lxxiv ) Ms Channel ( 75X40x6 Mm ) For Supporting H.G Fuse & L.A [ Non Galvanized ] ( Lxxv ) Clamp ( 50 X 6 Mm ) For Transformer Base Channel [ Galvanized ] ( Lxxvi ) Clamp ( 50 X 6 Mm ) For Transformer Base Channel [ Non Galvanized ] ( Lxxvii ) Clamp ( 50 X 6 Mm ) For Transformer Belting [ Galvanized ] ( Lxxviii ) Clamp ( 50 X 6 Mm ) For Transformer Belting [ Non Galvanized ] ( Lxxix ) Clamp ( 50 X 6 Mm ) For Lt Bus & H.G Fuse Set [ Galvanized ] ( Lxxx ) Clamp ( 50 X 6 Mm ) For Lt Bus & H.G Fuse Set [ Non Galvanized ] ( Lxxxi ) D P Channel Support Clamp ( 50X6 Mm ) Feet ( 1 Pair = 1 Set ) For 60Kg Rail Pole [ Galvanized ] ( Lxxxii ) D.P Channel Support Clamp ( 50X6 Mm ) ) For 60Kg Rail Pole [ Non Galvanized ] ( Lxxxiii ) D P Channel Support Clamp ( 50X6 Mm ) Feet ( 1 Pair = 1 Set ) For 9 Mtr 400Kg Psc Pole [ Galvanized ] ( Lxxxiv ) D.P Channel Support Clamp ( 50X6 Mm ) For 9 Mtr 400Kg Psc Pole [ Non Galvanized ] ( Lxxxv ) D P Channel Support Clamp ( 50X6 Mm ) Feet ( 1 Pair = 1 Set ) For 8 Mtr 200Kg Psc Pole [ Galvanized ] ( Lxxxvi ) D.P Channel Support Clamp ( 50X6 Mm ) For 8 Mtr 200Kg Psc Pole [ Nongalvanized ] ( Lxxxvii ) D P Channel Support Clamp ( 50X6 Mm ) Feet ( 1 Pair = 1 Set ) For Tublar Pole [ Galvanized ] ( Lxxxviii ) D P Channel Support Clamp ( 50X6 Mm ) Feet ( 1 Pair = 1 Set ) For Tublar Pole [ Non Galvanized ] ( Lxxxix ) D P Channel Clamp ( 40X6 Mm ) Flat For 60 Kg Rail Pole [ Galvanized ] ( Xc ) D P Channel Clamp ( 40X6 Mm ) Flat For 60 Kg Rail Pole [ Non Galvanized ] ( Xci ) D P Channel Clamp ( 40X6 Mm ) Flat 9 Mtr 400Kg Psc Pole [ Galvanized ] ( Xcii ) D P Channel Clamp ( 40X6 Mm ) Flat 9 Mtr 400Kg Psc Pole [ Non Galvanized ] ( Xciii ) D P Channel Clamp ( 40X6 Mm ) Flat 8 Mtr 200Kg Psc Pole [ Galvanized ] ( Xciv ) D P Channel Clamp ( 40X6 Mm ) Flat 8 Mtr 200Kg Psc Pole [ Non Galvanized ] ( Xcv ) D P Channel Clamp ( 40X6 Mm ) Flat For Tublar Pole [ Galvanized ] ( Xcvi ) D P Channel Clamp ( 40X6 Mm ) Flat For Tublar Pole [ Non Galvanized ] ( Xcvii ) 33Kv Cross Bracing For D P Structure [ Galvanized ] ( Xcviii ) 33 Kv Cross Bracing For Dp Channel [ Non Galvanized ] ( Xcix ) 11 Kv Cross Bracing For D P Structure [ Galvanized ] ( C ) 11 Kv Cross Bracing For D P Structure [ Non Galvanized ] ( Ci ) Clamp For Cross Bracing Set Of 2 Pair For 60Kg Rail Pole [ Galvanized ] ( Cii ) Clamp For Cross Bracing Set Of 2 Pair For 60Kg Rail Pole [ Non Galvanized ] ( Ciii ) Clamp For Cross Bracing Set Of 2 Pair For 9 Mtr 400Kg Psc Pole [ Galvanized ] ( Civ ) Clamp For Cross Bracing Set Of 2 Pair For 9 Mtr 400Kg Psc Pole [ Non Galvanized ] ( Cv ) Clamp For Cross Bracing Set Of 2 Pair For 8 Mtr 200Kg Psc Pole [ Galvanized ] ( Cvi ) Clamp For Cross Bracing Set Of 2 Pair For 8 Mtr 200Kg Psc Pole Non [ Galvanized ] ( Cvii ) Clamp For Cross Bracing Set Of 2 Pair For Tublar Pole [ Galvanized ] ( Cviii ) Clamp For Cross Bracing Set Of 2 Pair For Tublar Pole [ Non Galvanized ] ( Cix ) Support Clamp For Cross Bracing For 60Kg Rail Pole [ Galvanized ] ( Cx ) Support Clamp For Cross Bracing For 60Kg Rail Pole [ Non Galvanized ] ( Cxi ) Support Clamp For Cross Bracing For 9 Mtr 400Kg Psc Pole [ Galvanized ] ( Cxii ) Support Clamp For Cross Bracing For 9 Mtr 400Kg Psc Pole [ Non Galvanized ] ( Cxiii ) Support Clamp For Cross Bracing For 8 Mtr 200Kg Psc Pole [ Galvanized ] ( Cxiv ) Support Clamp For Cross Bracing For 8 Mtr 200Kg Psc Pole [ Non Galvanized ] ( Cxv ) Support Clamp For Cross Bracing For Tublar Pole [ Galvanized ] ( Cxvi ) Support Clamp For Cross Bracing For Tublar Pole [ Non Galvanized ] ( Cxvii ) Angle / Side Stay Clamp ( 50X6 Mm ) For 60Kg Rail Pole [ Galvanized ] ( Cxviii ) Angle / Side Stay Clamp ( 50X6 Mm ) For 60Kg Rail Pole [ Non Galvanized ] ( Cxix ) Angle / Side Stay Clamp ( 50X10 Mm ) For 9 Mtr 400Kg Psc Pole [ Galvanized ] ( Cxx ) Angle / Side Stay Clamp ( 50X10 Mm ) For 9 Mtr 400Kg Psc Pole [ Non Galvanized ] ( Cxxi ) Angle / Side Stay Clamp ( 50X6 Mm ) For 8 Mtr 200Kg Psc Pole [ Galvanized ] ( Cxxii ) Angle / Side Stay Clamp ( 50X6 Mm ) For 8 Mtr 200Kg Psc Pole [ Non Galvanized ] ( Cxxiii ) Angle / Side Stay Clamp ( 50X6 Mm ) For Tublar Pole [ Galvanized ] ( Cxxiv ) Angle / Side Stay Clamp ( 50 X 6 Mm ) For Tublar Pole [ Non Galvanized ] ( Cxxv ) Clamp For G.I. Pipe ( Cxxvi ) Ms Flat ( 75X40x6 Mm ) [ Galvanized ] ( Cxxvii ) Ms Flat ( 75X40x6 Mm ) [ Non Galvanized ] ( Cxxviii ) Earth Clamp For Earthwire ( 50 X 6 Mm ) [ Galvanized ] ( Cxxix ) Earth Clamp For Earthwire ( 50 X 6 Mm ) [ Non Galvanized ] ( Cxxx ) Ms Angle For Lt Distribution Bus ( 35X35x6 Mm ) 1 Set For 2 Pair [ Galvanized ] ( Cxxxi ) Ms Angle For L T Distribution Bus ( 35 X 35 X6 Mm ) [ Non Galvanized ] ( Cxxxii ) Lt Bracket Vertical Formation ( Cxxxiii ) Lt Bracket For Tapping Point ( Cxxxiv ) Lt Angle Bracket ( 35X35x6 Mm ) [ Galvanized ] ( Cxxxv ) Lt Angle Bracket ( 35 X 35 X 6 Mm ) [ Non Galvanized ] ( Cxxxvi ) Ms Flat 35X6 Mm ( D-Ring ) For 10 Connections [ Galvanized ] ( Cxxxvii ) Ms Flat 35X6 Mm ( D-Ring ) For 10 Connections [ Non Galvanized ] ( Cxxxviii ) Pole Clamp For I Hook B Type ( Cxxxix ) Lt Back Clamp ( 50 X 6 Mm ) For Lt Angle [ Galvanized ] ( Cxl ) Lt Back Clamp ( 50 X 6 Mm ) For Lt Angle [ Non Galvanized ] ( Cxli ) U Clamp ( 40 X 6 Mm ) [ Galvanized ] ( Cxlii ) U Clamp ( 40 X 6 Mm ) [ Non Galvanized ] ( Cxliii ) 50 X 6 Mm Galvanized Gi Flat ( Risers ) ( Cxliv ) 25 X 3 Mm Galvanized Gi Flat ( Risers ) M1655 D.O. Fuse ( I ) 11 Kv D.O. Fuse Unit ( Polymer Type ) ( Ii ) 33 Kv D.O. Fuse Unit ( Polymer Type ) M1656 Electrical Conduit ( Pipes ) ( I ) Gi Pipe 4 Medium Duty ( B Class ) ( Ii ) Gi Pipe 6 Medium Duty ( B Class ) ( Iii ) Gi Pipe 8 Medium Duty ( B Class ) ( Iv ) Hume Pipe - Rcc Pipe 100 Mm ( Np2 Class ) ( V ) Hume Pipe - Rcc Pipe 150 Mm ( Np2 Class ) ( Vi ) Hume Pipe - Rcc Pipe 200 Mm ( Np3 Class ) M1657 Heat Shrinkable Kit ( I ) 33 Kv 3-Core Xlpe Ug Cable Heat Shrinkable Straight Through Jointing Kit Suitable For 400 Mm2 ( Ii ) 33 Kv 3-Core Xlpe Ug Cable Heat Shrinkable Straight Through Jointing Kit Suitable For 300 Mm2 ( Iii ) 33 Kv 3-Core Xlpe Ug Cable Heat Shrinkable Straight Through Jointing Kit Suitable For 240Mm2 ( Iv ) 33 Kv 3-Core Xlpe Ug Cable Heat Shrinkable Straight Through Jointing Kit Suitable For 185 Mm2 ( V ) 33 Kv Termination Kit For 1Core X 400Mm2 ( Vi ) 11 Kv Termination Kit For 3Core X 630Mm2 ( Vii ) In Door Heat Shrink Type Cable Termination Kit 11Kv Ht Xlpecable-1Cx 630 Sqmm ( Armoured ) ( Viii ) Out Door Heat Shrink Type Cable Termination Kit 11Kv Ht Xlpecable-1Cx 630 Sqmm ( Armoured ) ( Ix ) Lt Xlpe 3-3.5-4 Core Heat Shrinkable Straight Through Cable Jointing Kit 400 Mm2 ( X ) Lt Xlpe 3-3.5-4 Core Heat Shrinkable Straight Through Cable Jointing Kit 300-185 Mm2 ( Xi ) Lt Xlpe 3-3.5-4 Core Heat Shrinkable Straight Through Cable Jointing Kit 150-70 Mm2 ( Xii ) Lt Xlpe 3-3.5-4 Core Heat Shrinkable Straight Through Cable Jointing Kit 50-25 Mm2 ( Xiii ) Lt Xlpe 3-3.5-4 Core Heat Shrinkable Straight Through Cable Jointing Kit 4-16 Mm2 ( Xiv ) Lt Xlpe 3-3.5-4 Core Heat Shrinkable Indoor-Outdoor Cable Jointing Kit 400 Mm2 ( Xv ) Lt Xlpe 3-3.5-4 Core Heat Shrinkable Indoor-Outdoor Cable Jointing Kit 185- 300 Mm2 ( Xvi ) Lt Xlpe 3-3.5-4 Core Heat Shrinkable Indoor-Outdoor Cable Jointing Kit 70-150 Mm2 ( Xvii ) Lt Xlpe 3-3.5-4 Core Heat Shrinkable Indoor-Outdoor Cable Jointing Kit 25-50 Mm2 ( Xviii ) Lt Xlpe 3-3.5-4 Core Heat Shrinkable Indoor-Outdoor Cable Jointing Kit 4-16 Mm2 M1658 Ug Cables Related Material ( I ) Pillar Box Cum Consumer Service Distribution Box-One Time Lock System ( 1 No. 3 Ph 4 Wire Incoming And 5 Nos. 3Ph 4 Wire Outgoing ) ( Ii ) Cable Marker ( Metal ) M1659 ( ) Ab Switch Contact ( I ) Male Female Contact Of 33 Kv Ab Switch 600-630 Amp ( Ii ) Male Female Contact Of 33 Kv Ab Switch 400 Amp ( Iii ) Male Female Contact Of 33 Kv Ab Switch 200 Amp ( Iv ) Male Female Contact Of 11 Kv Ab Switch 800 Amp ( V ) Male Female Contact Of 11 Kv Ab Switch 600 Amp ( Vi ) Male Female Contact Of 11 Kv Ab Switch 400 Amp ( Vii ) Male Female Contact Of 11 Kv Ab Switch 200 Amp M1660 Testing Equipment ( I ) Accuchek Meter High Accuracy ( 0.2% In Director Mode / 0.5% In Clamp On Mode ) For Kwh, Kvarh And Kvah Maximum Current Up To 6A In Direct Mode And Up To 500A In Clamp On Mode. Lt+ : To Test Lt Whole Current Single Phase Meters Up To 60A ( Ii ) Accuchek Meter High Accuracy ( 0.2% In Director Mode / 0.5% In Clamp On Mode ) For Kwh, Kvarh And Kvah Maximum Current Up To 6A In Direct Mode And Up To 500A In Clamp On Mode. Lt+ : To Test Lt 3 Phase & Ct Operated Energy Meters ( Iii ) Accuchek Meter High Accuracy ( 0.2% In Director Mode / 0.5% In Clamp On Mode ) For Kwh For Ht+ : To Test Meters Suitable For Ht, 3 Phase, 3 Wire And 4 Wire Systems ( Iv ) Eh-Ii Chain Electric Hoist ( Capacity - 1 Ton, Standard Lift - 3 Mtr ) With 1.5 Hp Motor ( V ) Electronic Weighing Machine With 1.2X1.2 Mtr. Platform, Suitable For Weighing Limit Upto 2 Tons ( Vi ) Electronic Weighing Machine With 2X2 Mtr. Platform, Suitable For Weighing Limit Upto 4 Tons ( Vii ) Earth Tester 200 Amp. 2000 Ohm ( Digital ) ( Viii ) 500 V Megger ( Ix ) 2.5 / 5 Kv Megger ( Mannual ) ( X ) Digital Clamp Meter ( Meco 3150 ) ( Xi ) Digital Tong Tester ( 1000 Amp., 500 V ) With Associated Accessories. ( Xii ) Digital Multi Meter ( 10 Amp Along With Ma Range ) ( Xiii ) 2.5 Kv Motorised With Range Up To 20000 Mega Ohms ( Xiv ) 2.5 Kv Motorised Cum Manual With Range Up To 20000 Mega Ohms ( Xv ) 5 Kv Motorised With Range Up To 100000 Mega Ohms ( Xvi ) 5 Kv Motorised Cum Manual With Range Up To 100000 Mega Ohms M1661 Tool Kit ( I ) Adhesive Insulation Tape ( Ii ) High Temperature Tape ( Iii ) Dicharge Rod For 33 Kv / 11Kv ( Iv ) Screw Driver Set-840 ( V ) Screw Driver Set-935 ( Vi ) Neon Tester 813 ( Vii ) Hammer 200 Gm ( Viii ) Hack Saw Frame ( Ix ) Hack Saw Blades ( X ) Adjustable Spanner ( Xi ) Wire Stripper ( Xii ) Combinational Plier ( Xiii ) Side Cutting Plier ( Xiv ) Measuring Tape ( Xv ) Hand Drill Machine ( Xvi ) Punch ( Xvii ) Knife ( Xviii ) Spanner Set ( Xix ) Tool Bag ( Xx ) Nose Plier ( Xxi ) Drill Bit 3 / 10 Concrete ( Jk ) ( Xxii ) Chain Pulley 5Ton With 15 Meter Chain ( Xxiii ) Max Pulley 10 Ton M1662 Civil Works ( I ) Opc Cement ( Ii ) Earth Work In Excavation In Foundation Trenches ( Along With Disposal Of Excavated Earth Upto 50M, Removing Tree Roots And Shrubs ) ( For Normal Soil ) ( Iii ) Earth Work In Excavation In Foundation Trenches ( Along With Disposal Of Excavated Earth Upto 50M, Removing Tree Roots And Shrubs ) ( For Rocky Soil ) ( Iv ) Filling In Foundation Trenches And Plenth In Layers Not Exceeding 150 Mm Thick Well Watered, Rammed Fully Compacted And Fine Dressed With Earth Obtained From Excavation Of Foundation Trenches Within A Lead Of 50 M And Lift Of 1.5 M All Complete As Per Building Specification And Direction Of E / I ( V ) Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150 Mm Thick With All Leads And Lifts Including Cost Of All Material Labor, Royalty And Taxes All Complete As Per Building Specification And Direction Of E / I” ( Vi ) Brick Flat Soling ( Vii ) Providing P.C.C.M -150 In Nominal Mix ( 1:2:4 ) In Foundation With Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating, Striking, Curing, Taxes And Royalty All Complete As Perbuilding Specification And Direction Of Engineer In Charge ( Viii ) Providing P.C.C.M -100 In Nominal Mix ( 1:3:6 ) In Foundation With Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating, Striking, Curing, Taxes And Royalty All Complete As Perbuilding Specification And Direction Of Engineer In Charge ( Ix ) Providing P.C.C.M -75 In Nominal Mix ( 1:4:8 ) In Foundation With Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating, Striking, Curing, Taxes And Royalty All Complete As Perbuilding Specification And Direction Of Engineer In Charge ( X ) Providing R.C.C.M-150 With Nominal Mix ( 1:2:4 ) In Foundation And Plinth And With Quality Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M. 2.5 To 3 Incuding Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Striking, Curing ( But Excluding The Cost Of Reinforcement, Taxed And Royalty All Complete, As Per Building Specification And Direction Of E / I. ) M1663 ( ) Scada Related Materials ( A ) Scada Server ( I ) Fep Server With Interface Switches For Rtus And Frtus ( Ii ) Isr Server { Data Server } ( Iii ) Nms Server { Dms Server } ( Iv ) Dts Server ( Only At Ranchi ) ( V ) Developmental Server ( Vi ) Communication Server ( Vii ) Web / Directory Server ( Viii ) Workstation With Dual Tft Monitors ( Ix ) Led Based Video Projection System With 2X3 Module Configuration With Each Module At Least 67 Diagonal With Common Projector ( X ) 33 Kv Or 11 Kv Control And Relay Panel, Scada Compatable For Feeder Protection ( 1F ) ( Xi ) 33 Kv Or 11 Kv Control And Relay Panel, Scada Compatable For Transformer Protection ( It ) With O / C +E / F + Diff Relay ( Xii ) 33 Kv Or 11 Kv Control And Relay Panel, Scada Compatable For Feeder Protection ( 2F ) ( Xiii ) Buchholz Relay Contact ( Xiv ) Minimum Oil Gauge ( Xv ) Scada Compatible Winding Temp. Indicator ( Xvi ) Scada Compatible Oil Temp. Indicator ( Xvii ) Rtu Base Equipment Comprising Panels, Racks, Sub Racks, Powe Suppy Modules, Cpu, Analog And Digital Input Control Output Modules, Interfacing Mft Using Rs - 485 Modbus Protocol And 2 Ethernet Ports + 4 Serial Ports ( Rs232 / 485 ) , Required A-D Converters And All Other Accessories Required ( Xviii ) Dc Voltage Transducer ( Xix ) Rtu Base And Foundation ( Base Should Be Capable Of Withstanding 200 Kg. Load ) ( Xx ) Multi Function Transducers ( 5 Amps, 110 V With Rs 485 Modbus Communication Protocol ) ( Xxi ) Type A Frtu For 5- Way Rmus ( Xxii ) Type A Frtu For 4- Way Rmus ( Xxiii ) Type B Frtu For 3- Way Rmus ( Xxiv ) Type C Frtu For 2- Way Rmus ( Xxv ) Routers 230 V Ac, 2 Ge Ports, 48Xfe, Wan Speed 200 Mbps ( Xxvi ) Ethernet Switch ( Xxvii ) 2 Mbps Vpn Link For Connectivity For S / S With Scada Control Center ( Xxviii ) Ldms ( Xxix ) 2 Kva Ups ( For Ldms ) With 160 Ah Battery, 72 V Battery Set ( Xxx ) 6 Kva Ups ( Xxxi ) Gsm / Gprs Modem Along With Accessories ( Xxxii ) 5 Kva Ups ( Xxxiii ) 12 U Network Rack ( Xxxiv ) Hp Eio Code ( Xxxv ) Interrupter ( Xxxvi ) Cmri 3Phase ( Xxxvii ) B / W Laser Printer For Ldms ( Xxxviii ) 48 V Dc Power Supply System Based On Smps For Rtu & Comm. Equipment With 80 Ah Battery ( Xxxix ) Cat 6 Cable ( Xl ) Ldms Software ( Xli ) Numerical Relay Scada Compatible For Power Transformer Protection ( Xlii ) Numerical Relay Scada Compatible For 33Kv And 11 Kv Feeder Protection ( Xliii ) Mcu Module Card ( Xliv ) Power Module Card ( Xlv ) Di Card ( Xlvi ) Do Card ( Xlvii ) Ai Card ( Xlviii ) Com 6 Card ( Xlix ) Rmu - 3 Way ( 1 Incomer, 1 Outgoing And 1 Breaker ) Scada Compatible ( L ) Rmu - 5 Way ( 1 Incomer, 1 Outgoing And 3 Breakers ) Scada Compatible ( Li ) 11 Kv Sectionalizer ( Lii ) 11 Kv Auto Reclosure ( Liii ) Gprs / Cdma / Edge / 3G Modem ( Liv ) Heavy Duty Relay For Cb Trip / Close ( 48 V Dc, 2 No, 1 Nc ) ( Lv ) 48 V Dcps At Rtu Locations Along With Vrla Batteries ( Lvi ) 11 Kv Stand Alone Fault Passage Indicator Complete With Gprs Enabled Modem ( Scada Compatible ) ( Lvii ) 33 Kv Stand Alone Fault Passage Indicator Complete With Gprs Enabled Modem ( Scada Compatible ) ( B ) Storage & Backup Devices ( I ) External Raid Mass Storage Device ( For 2 Months Online Backup ) ( Ii ) External Dat Drive ( C ) Switches ( I ) Layer Ii Switch ( Scada / Dms Lan ) ( 48 Ports ) ( Ii ) Layer Switch ( Planning & Development System Lan ) ( 24 Ports ) ( D ) Other Active Devices ( I ) Gps Time Synchronization System ( Ii ) Time, Day & Date Digital Displays ( E ) Printers ( I ) A3 Color Inkjet Printer ( Ii ) B / W Laser Printer ( Iii ) Color Laser Printer ( F ) Security System ( Dmz ) ( I ) Web Server With Load Balancing ( Ii ) Mail Server ( 1+1 ) Included In It System ( Iii ) Firewall & Network Ids / Ips In Pair ( 2 Nos. ) ( G ) Cabling System ( I ) Cable, Jacks, Hubs, Etc. ( Ii ) Acdb For Control Centre ( Iii ) Kvm Switch ( Iv ) Panels ( H ) Software For Control Centre ( I ) Scada Software ( Ii ) Isr Software ( Iii ) Dms Software ( Iv ) Dts Software ( V ) Developmental Software ( Vi ) Network Management Software ( Vii ) Web / Network Security Software ( Included In It Package ) ( Viii ) Rdbms Package ( Included In Isr ) ( Ix ) Gis Adaptor / Engine For Importing Data From Gis System Under It System ( I ) Form: F-4: Rtu:Rtu-Type B 33 / 11 Kv Sub Stations ( I ) Rtu Base Equipment Comprising Panels, Racks, Sub-Racks, Power Supply Modules, Cpu, Analog And Digital Input Control Output Modules, Interfacing Equipments For Interfacing Mfts Using Rs-485 Modbus Protocol And 2 Eathernet Ports, Required A-D Converters & All Other Required Items / Accessories Including Complete Wiring For All Modules For Locations Mentioned For Type B Rtus ( Ii ) Multifunction Transducers ( Mfts ) ( Iii ) Contact Multiplying Relays ( Cmrs ) ( Iv ) Heavy Duty Relays ( Hdrs ) For Cb Trip / Close And Rise And Lower Of Oltc ( V ) Weather Transducer - Wind Speed ( Vi ) Weather Transducer - Rainfall ( Vii ) Weather Transducer - Humidity ( Viii ) Weather Transducer -Temperature ( Ix ) Weather Transducer -Wind Direction ( X ) Router For Rtus At Dc Power Supply ( Xi ) Oltc Transducers ( Xii ) Dc Current Transducer ( Xiii ) Dc Voltage Transducer ( Xiv ) Acdb With Sufficient Mccbs ( J ) Test Equipments For Rtu ( I ) Rtu Database Configuration & Maintenance Software Tool ( Ii ) Master Station Cum Rtu Simulator & Protocol Analyzer Software Tool ( Iii ) Laptop Pc For Above Software Tools Along With Interfacing Hardware Including Hub ( K ) Form: F-5:Frtu / Frtus ( I ) Mini Frtu Base Equipment Along With Enclosuress Suitable To Work In Open Environment Withadequate Protection To Water & Dust, With Racks, Sub-Racks, Power Supply Modulesi / O Modules, Cpu, Interfacing Equipments, Required A-D Converters & All Other Required Items / Accessories Including Complete Wiring For All Modules For Frtu Locations. ( Ii ) Type-A Frtu For 5-Way Rmus ( Iii ) Type-A1 Frtu For 4-Way Rmus ( Iv ) Type-B Frtu For 3-Way Rmus ( V ) Type-C Frtu For Sectionalizers ( Vi ) Mfts ( Vii ) Contact Multiplying Relays ( Cmrs ) ( Viii ) Heavy Duty Relays For Cb Trip / Close ( L ) Test Equipments For Frtu ( I ) Frtu Database Configuration & Maintenance Software Tool ( Ii ) Master Station Cum Frtu Simulator & Protocol Analyzer Software Tool ( Iii ) Laptop Pc For Above Software Tools Along With Interfacing Hardware Including Hub ( M ) F4: Gprs / Cdma / Edge / 3Gmodems ( I ) Gprs ( Ii ) Cdma-For Frtu Locations + 3 At Hub ( No Back Up To Rtus Allowed ) ( Iii ) Edge ( Iv ) 3G ( N ) Form: F-7: Auxiliary Power Supply System ( Aps ) ( I ) 20 Kva Ups ( 1+1 ) With Vrla Batteries To Give 4 Hrs Back Up ( Ii ) Dc Power Supply ( Dcps ) System Based On Smps ( For 20 A Load Plus Charging Current@10% Capacity ) With Vrla Batteries To Give 4 Hrs Back Up. ( Iii ) 10 Kva Ups ( 1+1 ) With Vrla Batteries To Give 4 Hrs Back Up ( Iv ) Dc Power Supply ( Dcps ) System Based On Smps ( For 20 A Load Plus Charging Current@10% Capacity ) With Vrla Batteries To Give 4 Hrs Back Up. ( V ) 2 Kva Ups For Rtu Locations / Ldms ( Vi ) 48 V Dcps At Rtu Locations Along With Vrla Batteries ( Vii ) 24 / 48 V Dcps For Frtu Locations Along With Vrla Batteries ( O ) Cards For Rtu And Frtu ( I ) Mcu-1-A Module Card Of Rtu ( Ii ) Mcu-4-A Module Card Of Rtu ( Iii ) Comm Module Card Of Rtu ( Iv ) Power Module Card Of Rtu ( V ) Di Card Of Rtu ( Vi ) Do Card Of Rtu ( Vii ) Ai Card Of Rtu ( Viii ) Mcu Module Card Of Frtu ( Ix ) Power Module Card Of Frtu ( X ) Di Card Of Frtu ( Xi ) Do Card Of Frtu M1664 Safety Equipment ( I ) Rechargeable Led Hand Torch ( Ii ) Safety Helmet - Pvc ( Iii ) Safety Shoes ( Electrical Safety ) ( Iv ) Rubber Hand Gloves ( 1.1Kv ) Commander ( V ) Safety Double Adjustable Belts ( Karam ) ( Vi ) Safety Items As Per The Requirement Of Electrical Inspector As Under First Aid Box, Shock Treatment Chart, Rubber Matts 8 Mm Thick, 4 Fire Buckets With Sand & M.S. Hooks / Stand, Helmet, Hand Gloves And, Fire Extinguisher ( 2 Nos ) M1665 Fire Extinguishers ( I ) I Kg Dry Chemical Powder ( Map 50% ) ; Fire Rating : 1A, 8B ( Ii ) 2 Kg Dry Chemical Powder ( Map 50% ) ; Fire Rating: 2A, 8B ( Iii ) 4 Kg Dry Chemical Powder ( Map 50% ) ; Fire Rating : 2A, 21B ( Iv ) 6 Kg Dry Chemical Powder ( Map 50% ) ; Fire Rating: 3A, 34B ( V ) 9 Kg Dry Chemical Powder ( Map 50% ) Fire Rating: 4A, 55B ( Vi ) 6 Ltr Water Type; Fire Rating : 2A 1 2 ( Vii ) 9 Ltr Water Type, Fire Rating: 3A ( Viii ) 6 Ltr Mechanical Foam Type, Fire Rating: 2A, 21B ( Ix ) 9 Ltr Mechanical Foam Type, Fire Rating: 4A, 34B ( X ) 2 Kg Carbon Dioxide Type, Fire Rating: 8B ( Xi ) 3 Kg Carbon Dioxide Type, Fire Rating: 13B ( Xii ) 4.5 Kg Carbon Dioxide Type, Fire Rating: 21B ( Xiii ) 6.5 Kg Carbon Dioxide Type, Fire Rating: 55B ( Xiv ) 9 Kg Carbon Dioxide Type, Fire Rating: 70B ( Xv ) 22.5 Kg Carbon Dioxide Type, Fire Rating: 70B ( Xvi ) Gas Pressure Ctc Fire Extinguisher ( Xvii ) Fire Buckets ( Capacity 10 Ltrs. ) M1666 ( ) Feeder Pillar / Smdb / Distribution Board ( I ) Lt Mini Feeder Pillar ( Simple With Fuse Arrangement ) ( Aluminium Bus ) ( Ii ) Smdb ( 1 In, 3 Out ) With Housing 5 Nos 20 Amp Spn Mcb, ( Iii ) Tpn Distribution Board 12 Way, 50 Amp Tpn Mcb, ( Iv ) Tpn Distribution Board 12 Way, 100 Amp Tpn Mcb, ( V ) Tpn Distribution Board 12 Way, 150 Amp Tpn Mcb, ( Vi ) Lt Feeder Piller Box For 1 Phase 8 Connection Made Of M.S.Sheet. ( Vii ) Lt Feeder Piller Box For 1 Phase 12 Connection Made Of M.S.Sheet. ( Viii ) Lt Feeder Piller Box For 3 Phase 4 Connection Made Of M.S.Sheet. ( Ix ) Lt Feeder Piller Box For 3 Phase 8 Connection Made Of M.S.Sheet. ( X ) Lt Feeder Pillar ( Simple With Fuse Arrangement ) ( Aluminium Bus ) M1667 ( A ) Aluminium End Terminal ( I ) 10 Sq Mm ( Ii ) 225 Sq Mm M1668 Other Misc. Equipment ( I ) Earthing G.I.Strip ( 65X6 ) Mm2 ( Ii ) Rain Coat ( Iii ) Rubber Mat Along Length Of Pannel ( Iv ) Aluminium Pipe 40 Mm Dia ( V ) 400 Watt / 250 V Hpsv Lamp Fitting Complete For 33 / 11 Kv Pss Yard Lightining ( Vi ) 30 V 80 Ah Battery Charging Unit Complete With Battery And Stand ( Vii ) 30 Volts 100 Ah Lead Acid Battery With Battery Charger And Stand ( Viii ) 30V, 40 Amp. Float-Cum-Boost Battery Charger With Full Wave Rectification For 230 V, 1 Phase, 50 Hz Ac Input Supply As Per Technical Specifications. ( Ix ) Polycarbonate Seal Bit ( X ) Sticker Seal With Hologram ( Xi ) Earth Knob ( Xii ) Ms Earth Mat For Switch Yard ( Xiii ) Rail Piece 44.64Kg / M 6.92 Meter Long For Power Transformer ( Xiv ) Aluminium Binding Wire ( Xv ) Gi Wire No. 6 / 8 / 10 ( Xvi ) T / C Fuse Wire 12 / 14 / 16 / 18 / 22 / 28 / 32 Swg ( Xvii ) M S Nuts & Bolts Of Different Size ( Xviii ) Galvanised Nuts & Bolts ( Assorted Size ) ( Xix ) Jointing Sleeves ( Alumnium ) Suitable For 34 / 55 Sq.Mm ( Xx ) Jointing Sleeves ( Alumnium ) Suitable For 70-100 Sq.Mm ( Xxi ) Jointing Sleeves ( Alumnium ) Suitable For 150-232 Sq.Mm ( Xxii ) Anticlimbing Device ( Barbed Wire ) 2X12 Swg ( Xxiii ) Al Paint ( Xxiv ) Red Oxide Paint ( Xxv ) Lt Phase Seperator ( Xxvi ) 3 Mm Thick Ms Plate With Weight Of 0.36 Kg Asset Tag ( Xxvii ) Transformer Oil ( Ehv Grade ) ( Xxviii ) Natural Ester Oil ( Xxix ) C-Wedge Connector For 0.2Sq Panther Conductor ( Nominal Aluminum Area 200Mm2 ) ( Xxx ) Fault Locator Machine For Ug Cables ( Flc ) Without Vehicle ( Xxxi ) Transformer Oil Testing Kit ( 220 / 230 Ac ) ( Xxxii ) Transformer Oil Filter Machine ( 500 Gph ) ( B ) Furniture ( I ) Godrej Thrive Mid Back Revolving Chair - Size:75Cm ( W ) X 75Cm ( D ) X 100Cm-109Cm ( H ) X 45Cm-54Cm ( Seat Height ) . ( Ii ) Godrej Thrive Non-Revolving Visitor Chair - Size:63.5Cm ( W ) X 59.5Cm ( D ) X 97.5Cm ( H ) X 42.5Cm ( Seat Height ) . ( Iii ) Godrej Regency Non-Revolving Visitor Chair With Armrest - Size:59Cm ( W ) X 63Cm ( D ) X 81.5Cm ( H ) X 45Cm ( Seat Height ) . ( Iv ) Godrej Regency Mid Back Revolving Chair - Size:76.3Cm ( W ) X 76.3Cm ( D ) X 78.5Cm-90.5Cm ( H ) X 44.2Cm-54.2Cm ( Seat Height ) . ( V ) Godrej Bravo Mid Back Revolving Chair - Size:76.3Cm ( W ) X 76.3Cm ( D ) X 85.5Cm-97.5Cm ( H ) X 42.5Cm-54.5Cm ( Seat Height ) . ( Vi ) Godrej La Sede High Back Revolving Chair - Size:76.1Cm ( W ) X 76.1Cm ( D ) X 114.5Cm-131.5Cm ( H ) X 44.5Cm-54.5Cm Height ) . ( Vii ) Godrej La Sede Non-Revolving Visitor Chair - Size:60.9Cm ( W ) X 64.7Cm ( D ) X 98.2Cm ( H ) X 46.2Cm ( Seat Height ) . ( Viii ) Godrej Halo Very High Back Revolving Chair - Size:77Cm ( W ) X 77Cm ( D ) X 134.9Cm-143.9Cm ( H ) X 49.9Cm-58.9Cm ( Height ) . ( Ix ) Godrej Halo Non-Revolving Visitor Chair - Size:59Cm ( W ) X 68.5Cm ( D ) X 89.5Cm ( H ) X 46.5Cm ( Seat Height ) . ( X ) Godrej Unlearn Single Seater Cpu / Laptop Table For Computer Training Hall -Size: 90Cm ( W ) X 60Cm ( D ) X 68Cm ( H ) ( Xi ) Godrej Unlearn 2 Seater Laptop Table For Meeting Hall - Size:135Cm ( W ) X 60Cm ( D ) X 68Cm ( H ) ( Xii ) Godrej Unlearn 4 Seater Laptop Table For Meeting Hall - Size:270Cm ( W ) X 60Cm ( D ) X 68Cm ( H ) ( Xiii ) Godrej Talk Unitised 4-Seater Round Table - Size:120Cm Dia X 75Cm ( H ) ( Xiv ) Godrej Talk Modular Conference Table - Size:67.5Cm ( W ) X 60Cm ( D ) X 75Cm ( H ) ( Xv ) Godrej Enterprise Table With Cpu Hanger - Size:165Cm ( W ) X 90Cm ( D ) X 72.8Cm ( H ) ( Xvi ) Godrej Insight Table For Library - Size:180Cm ( W ) X 90Cm ( D ) X 74Cm ( H ) ( Xvii ) Godrej Versatila V2 Table For Faculty Sitting Area - Size:150Cm ( W ) X 89.4Cm ( D ) X 75Cm ( H ) ( Xviii ) Godrej Aristo Executive Table With Right-Unit And Pedestal - Size:180Cm ( W ) X 210Cm ( D ) X 75Cm ( H ) ( Xix ) Godrej Impress Main Desk Table - Size: 180Cm ( W ) X 90Cm ( D ) X 75Cm ( H ) ( Xx ) Godrej Impress Back Unit For Impress Desk Table - Size: 221.5Cm ( W ) X 41Cm ( D ) X 200Cm ( H ) ( Xxi ) Godrej Display Unit Tv Cabinet Walnut Color - Size: 140Cm ( W ) X 40Cm ( D ) X 75.4Cm ( H ) ( Xxii ) Godrej Time Out 4-Seater Pu Coated Dining Table -Size: 113.5Cm ( W ) X 117.5Cm ( D ) X 75Cm ( H ) ( Xxiii ) Godrej Unwind Café Chair Without Armrest - Size: 52.5Cm ( W ) X 55.8Cm ( D ) X 84.5Cm ( H ) X 45Cm ( Seat Height ) ( Xxiv ) Godrej Neo Apple Dining Table 6 Seater Glass Top - Size: 160Cm ( W ) X 90Cm ( D ) X 75Cm ( H ) ( Xxv ) Godrej Novice Silver Dining Chair - Size: 44.5Cm ( W ) X 41.5Cm ( D ) X 96Cm ( H ) ( Xxvi ) Godrej Grande Dark Walnut Dining Chair - Size: 45Cm ( W ) X 45Cm ( D ) X 95Cm ( H ) ( Xxvii ) Godrej Alice Coffee Table Walnut Color - Size: 100Cm ( W ) X 65Cm ( D ) X 45Cm ( H ) ( Xxviii ) Godrej Pisa 3-Seater Leatherite Sofa - Size: 205.5Cm ( W ) X 92Cm ( D ) X 82Cm ( H ) ( Xxix ) Godrej Pisa 2-Seater Leatherite Sofa - Size: 100Cm ( W ) X 92Cm ( D ) X 82Cm ( H ) ( Xxx ) Godrej Pisa Single Seater Leatherite Sofa - Size: 86Cm ( W ) X 92Cm ( D ) X 82Cm ( H ) ( Xxxi ) Godrej Storwel Plain Almirah - Size: 91.6Cm ( W ) X 48.6Cm ( D ) X 198Cm ( H ) ( Xxxii ) Godrej Glass Door Storwel Almirah - Size: 91.6Cm ( W ) X 48.6Cm ( D ) X 198Cm ( H ) ( Xxxiii ) Godrej Single Sided Wood & Steel Book Rack Base Unit - Size:90Cm ( W ) X 30Cm ( D ) X 189Cm ( H ) ( Xxxiv ) Godrej All Steel Periodical Display Rack - Size:90Cm ( W ) X 45Cm ( D ) X 183Cm ( H ) ( Xxxv ) Godrej 4 Door Bookcase ( Without Top ) - Size:91.4Cmw X 32Cm ( D ) X 174.2Cm ( H ) ( Xxxvi ) White Board 4Ft. X 3Ft. With Stand ( Xxxvii ) L-Shaped Workstation Made Of 19Mm Thk White Mdf Board With Pvc Edges. ( Xxxvii ) Size:1800Mm ( L ) + 1200Mm ( L ) X 600Mm ( D ) X 1200Mm ( H ) ( C ) Led Tv ( I ) Supply, Installation, Testing And Commissioning Of 75 Ultra-Hd Led Television With All Accessories. ( Ii ) Make : Sony / Samsung / Lg ( Iii ) Supply, Installation, Testing And Commissioning Of 32 Hd Led Television With All Accessories. ( Iv ) Make : Sony / Samsung / Lg ( D ) Projector & Screen Set Complete ( I ) Supply, Installation, Testing And Commissioning Of Full Hd Projector With All Accessories Like Bracket, Ceiling Mount Kit Powder Coated For Projector, 4X6, 16:9 Aspect Ratio, Motorised Projection Screen Etc.Make : Epson / Canon / Panasonic ( E ) Split Type Air-Conditioners Set Complete ( I ) Supply, Installation, Testing And Commissioning Of 1.5Tr Split Ac Inverter Type 3 Star Rating With Ms Frame, Copper Pipe, Drain Pipe Etc.. Complete With All Accessories Like 5Kva Stabiliser, Wiring Etc.Make: Voltas / Daikin / Mitsubishi / Hitachi / Lg / Samsung ( Ii ) Supply, Installation, Testing And Commissioning Of 2Tr Split Ac Inverter Type 3 Star Rating With Ms Frame, Copper Pipe, Drain Pipe Etc.. Complete With All Accessories Like 5Kva Stabiliser, Wiring Etc.Make: Voltas / Daikin / Mitsubishi / Hitachi / Lg / Samsung ( F ) Water Purifier Cum Cooler Set Complete ( I ) Supplying, Installing, Testing & Commissioning Of Water Purifier Cum Cooler Of Following Specifications:- Make :- Bluestar / Eurak Forbes / Voltas / Zero-B / Kentstorage Tank :- 150 Litersno.Of Faucets - 2Nett Weight In Kg ( Approx ) - 95 Kgdimensions : 812Mm ( W ) X 612Mm ( D ) X 1210Mm ( H ) Refrigerant : R-22Current In Amps : 8.0Type Of Compressor : Rotarycooling Capacity - 150Litres Per Hourwater Tank Sheet Material And Thickness - Stainless Steel ( Grade Aisi 304 ) With Puf Insulation, Thickness > =0.6 Mmwater Tank Cover And Lid Bottom Sheet Material - High Impact Polystrene ( Hip ) Water Tank Cover And Lid Bottom Sheet Thickness - 1.5 Millimetercooler Cabinet Sheet Material - Stainless Steel ( Grade Aisi 304 ) Cooler Cabinet Sheet Thickness - 0.8 Millimeter ( G ) Sound System Set Complete ( I ) Supply, Installation, Testing & Commissioning Of Sound System ( Make: Ahuja / Bose ) Set Consisting Of Following Items:-I ) Amplifier With 5 Independent Channels And Can Provide Automatic Re-Settable Overcurrent, Overload, Overheating, Overvoltage, Under-Voltage And Dc Protection - 4 Nos.Ii ) 6W Ceiling Speaker With Max Spl1m / 1W 96Db . Frequency Response Of 80Hz-20Khz With A Dispersion Angle Of 160 Deg - 16 Nos.Iii ) 30W Wall Mount With Max Spl1m / 1W 96Db . Frequency Response Of 160Hz-20Khz - 12 Nos.Iv ) 2 X 1.5 Sq Mm Armoured Frls Cable - 1000 Mtsv ) Wireless Microphone System - 2 Nos.Vi ) Tabletop Wireless Microphone -64 Nos. Meter Box ( I ) Poly Carbonate Weather Proof Outdoor Type Meter Cover Boxes For Single Phase Meter Size 315Mm X 265Mm X 130Mm Along With Zinc Plated Clamps ( Ii ) Poly Carbonate Weather Proof Outdoor Type Meter Cover Boxes For Three Phase Meters 445Mm X 345Mm X 170Mm Along With Zinc Plated Clamps ( Iii ) Deep Drawn M.S. Sheet Weather Proof Outdoor Type Meter Cover Box For Single Phase Meter Size 300Mm X 250Mm X 160Mm Along With Zinc Plated Clamps ( Iv ) Deep Drawn M.S. Sheet Weather Proof Outdoor Type Meter Cover Box For Three Phase Meter Size 500Mm X 300Mm X 160Mm Along With Zinc Plated Clamps ( V ) Metal Box Of Ct 800 / 5 Amp ( Vi ) Meter Box Made Of M / S Sheet Etc. Crca Metal Sheet Each Fitted With 4No. Racing Cost Ct Ratio 400 / 5A ( Vii ) Meter Box ( Viii ) Meter Box Made Of M / S Sheet Etc. Crca Metal Sheet Each Fitted With 4No. Racing Cost Ct Ratio 800 / 5A ( Ix ) Metal Box Of Ct 400 / 5 Amp Gas Insulated Switchgear S / S ( I ) 30Kv, 10Ka, Metal Oxide, Station Class, Surge Arrester ( Scada Compliant ) ( For 33Kv Incoming Line, Ht Side Of 2Nos. Power Transformers And 33 / 0.433Kv Station Transformer ) - Outdoor Type With Surge Counter. ( Ii ) 33Kv Indoor Gas Insulated Switchgear Panel ( Scada Compliants ) With: Breaker: 36Kv, 1250 A, ( 25Ka S.C. Rating ) , 3-Ph, Indoor Type Breaker ( With 30V Dc Tripping / Closing Coil And Associated Control ) Along With Marshalling Box, Terminal Connectors And Required Accessories Complete As Per Applicable Ts Ct:36Kv, 1-Ph, 25Ka ( 800^00-200 / 1-1 -1 A ) Indoor Type Current Transformer, Having Three Secondary Cores ( Protection & Metering & Current Differential Protection ) Along With Terminal Connectors, Junction Box And Required Accessories Etc. Complete As Per Applicable Ts ( 1 Set = 3 Nos. ) Pts: 36Kv, 1-Ph, 33Kv / 110 V, Single Core Outdoor Type Potential Transformer Along With Terminal Connectors, Junction Box And Required Accessories Etc. Complete As Per Applicable Ts ( 1 Set= 3 Nos. ) And Digital Ammeter / Voltmeter / Energy Meter, O / C And E / F Relay Etc. The Cable Chamber Shall Have 3 Nos., 20Kv, 10 Ka Distribution Class Valve Type Lightning Arresters And Isolators Of Capacity Given In Ts. For Feeder Protection 1 2 ( Iii ) 33Kv Indoor Gas Insulated Switchgear Panel ( Scada Compliants ) Consisting Of 36 Kv Breaker-630A, 25 Ka For 3 Sec, Phase Single Busbar-1250A ( Copper ) , 36 Kv Single Phase, ( 800-400-200 / 1-1 A ) 3 Nos Of Indoor Type Cts, 33 Kv / 110Volts Potential Transformers, Indoor Mounting Type Control Panel, Control Cabelling Between Gis And Indoor Control Panel Required Accessories, Bi-Metalic Clamps, Ammeter , Voltmeter, Modem Compatible Dlms Compliant Class 1 Meter Static Vector Energy Meter, Relays And Accessories Complete For Bus Coupler Protection. ( Iv ) 33Kv Indoor Gas Insulated Switchgear Panel ( Scada Compliants ) Consisting Of 36 Kv Breaker-630A, 25 Ka For 3 Sec, Phase Single Busbar-1250A ( Copper ) , 36 Kv Single Phase, ( 800-400-200 / 1-1-1A ) 3 Nos Of Indoor Type Cts, 33 Kv / 110Volts Potential Transformers, Indoor Mounting Type Control Panel, Control Cabelling Between Breakers And Indoor Control And Required Accessories, Bi-Metalic Clamps, Ammeter , Voltmeter, Modem Compatible Dlms Compliant Class 1 Meter Tri-Vector Energy Meter, Relays And Accessories Complete For Power Transformer Protection. ( V ) 33Kv Indoor Gas Insulated Switchgear Panel ( Scada Compliants ) Consisting Of 36 Kv Breaker-630A, 25 Ka For 3 Sec, Phase Single Busbar-1250A ( Copper ) , 36 Kv Single Phase, ( 800-400-200 / 1-1-1A ) 3 Nos Of Indoor Type Cts, 33 Kv / 110Volts Potential Transformers, Indoor Mounting Type Control Panel, Control Cabelling Between Breakers And Indoor Control And Required Accessories, Bi-Metalic Clamps, Ammeter , Voltmeter, Modem Compatible Dlms Compliant Class 1 Meter Tri-Vector Energy Meter, Relays And Accessories Complete For Station Transformer Protection. ( Vi ) 11 Kv Indoor Gas Insulated Switch Gear Panel ( Scada Compliants ) Consisting Of 1250 A, 25Ka For 3 Seconds, 3-Ph, Indoor Type Breaker Along With 12 Kv, 1-Phase, 600-300 / 1-1-1-1 Amp 3 Nos Indoor Type Current Transformer, 11 Kv / Volts Potential Transformers, Indoor Mounting Type Control Panel For Transformer Breaker, Control Cabling Between Breaker And Indoor Control Panel And Required Accessories, Bi-Metallic Clamps, A-Meter, Volt-Meter, Modem Compatible Dlms Complaint Class A Static Tri-Vector Energy Meter, Relay & Accessories Complete For Transformer Protection ( Vii ) 12 Kv, 1250 A, 25Ka For 3 Seconds, 3-Ph, Indoor Gas Insulated Switch Gear Panel ( Scada Compliants ) Along With 1-Phase, 600-300 / 1-1-1-1 Amp 3 Nos Indoor Type Current Transformer, 11 Kv / 110 Volts Potential Transformers, Indoor Mounting Type Control Panel For Transformer Breaker, Control Cabling Between Breaker And Indoor Control Panel And Required Accessories, Bi-Metallic Clamps, A-Meter, Volt-Meter, Modem Compatible Dlms Complaint Class A Static Tri-Vector Energy Meter, Relay & Accessories Complete For Bus Coupler Protection ( Viii ) 12 Kv, 1250 A, 25Ka For 3 Seconds, 3-Ph, Indoor Gas Insulated Switch Gear Panel ( Scada Compliants ) Along With Kv, 1-Phase, 600-300 / 1-1-1-1 Amp 3 Nos Indoor Type Current Transformer, 11 Kv / 110 Volts Potential Transformers, Mounting Type Control Panel For Transformer Breaker, Control Cabling Between Breaker And Indoor Control Panel And Required Accessories, Bi-Metallic Clamps, A-Meter, Volt-Meter, Modem Compatible Dlms Complaint Class A Static Tri-Vector Energy Meter, Relay & Accessories Complete For Feeder Protection ( Ix ) Remote Terminal Unit ( Rtu ) & Accessories With Pc & Connections With 30 Nos. Analog Points For Voltage, Frequency, Mw, Mvar ; 3 Positional Analog Points For Oltc And 28 Digital Points For Breaker And Isolator Status. ( X ) Flexible Cu. Earth Bond 1Cm Dia & 500Mm Long, Both End Provision Of Socket Suitable For M-16 Bolts. ( Xi ) G-3 Gi Beam ( 5.05Mtr Long, Consisting Of 2 Nos 150X75 X5.7Mm ) For 33Kv Incoming Line - ( 2 Nos. Beam- One For Arrester And Other For Isolator, Nominal Unit Wt - 0.2 Mt ) ( Xii ) Gi Spikes With Cone And Gi ( 2 Nos ) Base Plate 10Mm ( 50X2500 Mm Gi Pipe ) ( Unit Wt=0.04 Mt ) ( Xiii ) 12 Kv, 630 A, 25Ka For 3 Seconds, 3-Ph Double Break Centre Rotating Type ( Dbcr ) , Gang Operated Isolator Along Earth Switch And Support Insulators, Operating Mechanism, Base Channel, Down Pipe And All Required Accessories Complete As Per Technical Specifications, Without Earth Switch For Substation Transformers. ( Xiv ) 60 Kg / Mtr Rail Pole Pieces 5.4 Mts ( 2.7X2 ) 44.62 Kg Per Mtr / Transformer ( Unit Wt=0.240 Mt ) ( Xv ) 2 Tier 2 Rows Cable Trench ( Internal Width 1500 Mm, Depth 680 Mm, Width 75X75x6 Mm Support Angles Fixed Rcc Column Of 250 X 250 Mm & With Ladder Type Cable Tray ( 45X45x5mm Two Angles At Both Side Having Welded Flats Of Mm At A Gap Of 150Mm ) For Power & Control Cable ( Xvi ) Chequerred Plate 1000X300x5.6Mm Thick For Cable Trench In Side Control Room 12 Mtr ( Xvii ) Overhead Hoist Beam Mounted Remote Opertated For Lifting Of Equipment Of Control Room, Capacity 5 Tonnes ( Xviii ) 36Kv, 800 A, 25Ka For 3 Seconds, 3-Ph Double Break Centre Rotating Type ( Dbcr ) , Motorised Indoor Floor Mounted Off Load Isolator Along With All Required Accessories Complete As Per Technical Specifications, Scope Of Works And Approved ( Xix ) External Electrification In Switch Yard Area Including Power Receptacles, Station Yard Lighting With 6 Nos Lighting ( Fitted With 2X100 Watts Led Flood Light ) Made Of 11 Meters High Steel Tubular Poles ( Is 2713 Part I, Ii Iii ) Of Designation 410 – Sp - 60 And 6 Nos Light ( 1 X 250 W Led ) On Structure & Control Room Complete As Per Technical Specifications, Approved Drawings And Scope Of The Work. ( Xx ) Internal Electrification Works Of Control Room Comprising Of Main Distribution Board, Sub-Distribution Boards, Flexible Multi Conductor 2.5 Sqmm Wiring ( For Light & Fan ) / 4 Sqmm Wiring ( For Power Points ) , Power And Light Points, Conduits, Fan / Led Lamps / Tube Fittings, Exhaust Fans, Switches, Sockets, 2Mm Thick, Pvc 25Mm Dia Conduits Pipes In Plugs, Miniature Circuit Breakers, Seperate Independent Earthing ( 2 Nos Of 40Mm Gi Pipe / 3-M Long ) Etc As Required Including Dc Emergency Lighting And Auto-Change-Over Switch As Per Technical Specifcations, Approved Drawings And Of Work. M1671 ( ) Over Head Distance To Fault Locator ( Offline ) With Signature Analyser. A ) Accessories & Laptop As Per Latest Technical Specifications M1672 ( ) Tower Line For River Crossings ( I ) D Type Tower For 33Kv, 11Kv ( Double Circuit Line ) ( 13.56Mt Each ) With All Related Nuts And Bolts Including Foundation Nuts And Bolts ( G I Type ) ( Ii ) D Type Tower For 33Kv, 11Kv ( Four Circuit Line ) ( 15.14Mt ) ( Double Circuit Tower +3Meter Extension Each ) With All Related Nuts And Bolts Including Foundation Nuts And Bolts ( G I Type ) ( Iii ) Compression Type Tension Hardware Fitting For Earth Wire ( Iv ) Vibration Damper Suitable For 7 / 3.15 Mm Gi Earth Wire ( V ) 25X500 Mm Flexible Cu. Earth Bond. M1673 Covered Conductor & Accessories ( I ) Acsr Covered Panther Conductor ( 200 Sq. Mm ) ( Ii ) Acsr Covered Wolf Conductor ( 150 Sq. Mm ) ( Iii ) Acsr Covered Dog Conductor ( 100 Sq. Mm ) ( Iv ) Mid Span Joint ( 150 Sq Mm & 200 Sq Mm ) ( V ) Suspension Ties ( ( 150 Sq Mm & 200 Sq Mm ) ) ( Vi ) Tension Clamp ( Wedge Type ) ( ( 150 Sq Mm & 200 Sq Mm ) ) ( Vii ) Insulation Piercing Connector ( Bare To Covered ) ( ( 150 Sq Mm & 200 Sq Mm ) ) ( Viii ) Insulation Piercing Connector ( Covered To Covered ) ( ( 150 Sq Mm & 200 Sq Mm ) ) ( Ix ) Insulation Piercing Connector With Alumunium Bail For Earthing ( ( 150 Sq Mm & 200 Sq Mm ) ) ( X ) Mid Span Joint ( 100 Sq Mm & 50 Sq Mm ) ( Xi ) Suspension Ties ( ( 100 Sq Mm & 50 Sq Mm ) ) ( Xii ) Tension Clamp ( Wedge Type ) ( ( 100 Sq Mm & 50 Sq Mm ) ( Xiii ) Insulation Piercing Connector ( Bare To Covered ) ( 100 Sq Mm & 50 Sq Mm ) ( Xiv ) Insulation Piercing Connector ( Covered To Covered ) ( 100 Sq Mm & 50 Sq Mm ) ( Xv ) Insulation Piercing Connector With Aluminium Bail For Earthing ( 100 Sq Mm & 50 Sq Mm ) M1674 Led Lights And Related Items ( I ) Led Light-190W ( Ii ) Led Light-120W ( Iii ) Led Light-75W ( Iv ) Led Light-40W ( V ) 18 Watt Led Panel Bulb With Outer 205X205x25 Mm Sq. And 180X180 Mm Inner M1675 Diesel Generator Sets ( Three Phase ) With Amf Panel ( I ) 10Kva ( Ii ) 20Kva ( Iii ) 30Kva ( Iv ) 40Kva ( V ) 50Kva ( Vi ) 62.5Kva ( Vii ) 82.5Kva ( Viii ) 100Kva ( Ix ) 160Kva M1676 Trw Related Items ( I ) 1 / 2 L.T. Brass Studs ( Ii ) 1 / 2 H.T. Brass Studs ( Iii ) L.T Bushing 3347 250 Amp ( Iv ) L.T. Bushing 250 Amp ( V ) Kraft Paper 4 Mile ( Vi ) Insulating Paper Tap 2.0 Mm ( Vii ) Press Board 1 Mm ( Viii ) Bakelite Tube 3 / 8X1 / 2 ( Ix ) Empire Sleeving Size 4 Mm ( X ) R.C. Sheet 3 X2x1 / 2 Mm ( Xi ) Inline Connector 6 Mm ( Xii ) Cotton Tap 1 ( Xiii ) R.C. Strip ( Xiv ) R.C. Washer 50X28x2 ( Xv ) Silicagel Breather 200 Kva ( Xvi ) M.Seal ( Xvii ) C.I.Cap 1 8 1 / 2 ( Xviii ) Insulating Paper Top 2.5 Mil 20 Mm ( Xix ) Crap Paper ( Xx ) G.P. Thinner ( Xxi ) D.A. Gray Paint ( Xxii ) White Paint ( Xxiii ) Nylon Washer 3 / 4 ( Xxiv ) M.S. Plug ( Xxv ) L.T. Al.Strip 6.50X4.50 Mm M1677 Transformer Repairing Items ( I ) L.T Bushing Rod Assembly Of 750 Kva Transformer. ( Ii ) H.T Bushing Rod Assembly Of 750 Kva Transformer. ( Iii ) L.T Bushing Insulator Of 750 Kva Transformer. ( Iv ) H.T Bushing Insulator Of 750 Kva Transformer. ( V ) L.T Bushing Gasket Set Of 750 Kva Transformer. ( Vi ) H.T Bushing Gasket Set Of 750 Kva Transformer. ( Vii ) Tank Gasket Set Of 750 Kva Transformer. ( Viii ) Silica Gel Breather Of 750 Kva Transformer. ( Ix ) Arching Horn Of 750 Kva Transformer, ( X ) L.T Bushing Rod Assembly Of 500 Kva Transformer ( Xi ) H.T Bushing Rod Assembly Of 500 Kva Transformer ( Xii ) L.T Bushing Insulator Of 500 Kva Transformer ( Xiii ) H.T Bushing Insulator Of 500 Kva Transformer ( Xiv ) L.T Bushing Gasket Set Of 500 Kva Transformer ( Xv ) H.T Bushing Gasket Set Of 500 Kva Transformer ( Xvi ) Tank Gasket Set Of 500 Kva Transformer ( Xvii ) Silica Gel Breather Of 500 Kva Transformer ( Xviii ) Arching Horn Of 500 Kva Transformer ( Xix ) L.T Bushing Rod Assembly Of 400 Kva Transformer ( Xx ) H.T Bushing Rod Assembly Of 400 Kva Transformer ( Xxi ) L.T Bushing Insulator Of 400 Kva Transformer ( Xxii ) H.T Bushing Insulator Of 400 Kva Transformer ( Xxiii ) L.T Bushing Gasket Set Of 400 Kva Transformer ( Xxiv ) H.T Bushing Gasket Set Of 400 Kva Transformer ( Xxv ) Tank Gasket Set Of 400 Kva Transformer ( Xxvi ) Silica Gel Breather Of 400 Kva Transformer ( Xxvii ) Arching Horn Of 400 Kva Transformer ( Xxviii ) L.T Bushing Rod Assembly Of 315 Kva Transformer ( Xxix ) H.T Bushing Rod Assembly Of 315 Kva Transformer ( Xxx ) L.T Bushing Insulator Of 315 Kva Transformer ( Xxxi ) H.T Bushing Insulator Of 315 Kva Transformer ( Xxxii ) L.T Bushing Gasket Set Of 315 Kva Transformer ( Xxxiii ) H.T Bushing Gasket Set Of 315 Kva Transformer ( Xxxiv ) Tank Gasket Set Of 315 Kva Transformer ( Xxxv ) Silica Gel Breather Of 315 Kva Transformer ( Xxxvi ) Arching Horn Of 315 Kva Transformer ( Xxxvii ) L.T Bushing Rod Assembly Of 250 Kva Transformer ( Xxxviii ) H.T Bushing Rod Assembly Of 250 Kva Transformer ( Xxxix ) L.T Bushing Insulator Of 250 Kva Transformer ( Xl ) H.T Bushing Insulator Of 250 Kva Transformer ( Xli ) L.T Bushing Gasket Set Of 250 Kva Transformer ( Xlii ) H.T Bushing Gasket Set Of 250 Kva Transformer ( Xliii ) Tank Gasket Set Of 250 Kva Transformer ( Xliv ) Silica Gel Breather Of 250 Kva Transformer ( Xlv ) Arching Horn Of 250 Kva Transformer ( Xlvi ) L.T Bushing Rod Assembly Of 200 Kva Transformer ( Xlvii ) H.T Bushing Rod Assembly Of 200 Kva Transformer ( Xlviii ) L.T Bushing Insulator Of 200 Kva Transformer ( Xlix ) H.T Bushing Insulator Of 200 Kva Transformer ( L ) L.T Bushing Gasket Set Of 200 Kva Transformer ( Li ) H.T Bushing Gasket Set Of 200 Kva Transformer ( Lii ) Tank Gasket Set Of 200 Kva Transformer ( Liii ) Silica Gel Breather Of 200 Kva Transformer ( Liv ) Arching Horn Of 200 Kva Transformer ( Lv ) L.T Bushing Rod Assembly Of 100 Kva Transformer ( Lvi ) H.T Bushing Rod Assembly Of 100 Kva Transformer ( Lvii ) L.T Bushing Insulator Of 100 Kva Transformer ( Lviii ) H.T Bushing Insulator Of 100 Kva Transformer ( Lix ) L.T Bushing Gasket Set Of 100 Kva Transformer ( Lx ) H.T Bushing Gasket Set Of 100 Kva Transformer ( Lxi ) Tank Gasket Set Of 100 Kva Transformer ( Lxii ) Silica Gel Breather Of 100 Kva Transformer ( Lxiii ) Arching Horn Of 100 Kva Transformer ( Lxiv ) L.T Bushing Rod Assembly Of 63 Kva Transformer ( Lxv ) H.T Bushing Rod Assembly Of 63 Kva Transformer ( Lxvi ) L.T Bushing Insulator Of 63 Kva Transformer ( Lxvii ) H.T Bushing Insulator Of 63 Kva Transformer ( Lxviii ) L.T Bushing Gasket Set Of 63 Kva Transformer ( Lxix ) H.T Bushing Gasket Set Of 63 Kva Transformer ( Lxx ) Tank Gasket Set Of 63 Kva Transformer ( Lxxi ) Silica Gel Breather Of 63 Kva Transformer ( Lxxii ) Arching Horn Of 63 Kva Transformer ( Lxxiii ) L.T Bushing Rod Assembly Of 25 Kva Transformer ( Lxxiv ) H.T Bushing Rod Assembly Of 25 Kva Transformer ( Lxxv ) L.T Bushing Insulator Of 25 Kva Transformer ( Lxxvi ) H.T Bushing Insulator Of 25 Kva Transformer ( Lxxvii ) L.T Bushing Gasket Set Of 25 Kva Transformer ( Lxxviii ) H.T Bushing Gasket Set Of 25 Kva Transformer ( Lxxix ) Tank Gasket Set Of 25 Kva Transformer ( Lxxx ) Silica Gel Breather Of 25 Kva Transformer ( Lxxxi ) Arching Horn Of 25 Kva Transformer Ab Switch Repairing Item ( I ) Jaw Of Air Break Switch 600A ( Ii ) Blade Of Of Air Break Switch 600A ( Iii ) Post Insulator Of Air Break Switch 600A ( Iv ) Bearing Of Air Break Switch 600A ( V ) Phase Coupling Pipe Of Air Break Switch 600 A ( Vi ) Down Pipe Of Air Break Switch 600 A ( Vii ) Operating Handle Of Air Break Switch 600 A ( Viii ) Operating Leaver Of Air Break Switch 600 A ( Ix ) Connector Of Air Break Switch 600 A ( X ) Arching Horn Of Air Break Switch 600 A ( Xi ) Jaw Of Air Break Switch 400A ( Xii ) Blade Of Of Air Break Switch 400A ( Xiii ) Post Insulator Of Air Break Switch 400A ( Xiv ) Bearing Of Air Break Switch 400A ( Xv ) Phase Coupling Pipe Of Air Break Switch 400 A ( Xvi ) Down Pipe Of Air Break Switch 400 A ( Xvii ) Operating Handle Of Air Break Switch 400 A ( Xviii ) Operating Leaver Of Air Break Switch 400 A ( Xix ) Connector Of Air Break Switch 400 A ( Xx ) Arching Horn Of Air Break Switch 400 A ( Xxi ) Jaw Of Air Break Switch 200A ( Xxii ) Blade Of Of Air Break Switch 200A ( Xxiii ) Post Insulator Of Air Break Switch 200A ( Xxiv ) Bearing Of Air Break Switch 200A ( Xxv ) Phase Coupling Pipe Of Air Break Switch 200 A ( Xxvi ) Down Pipe Of Air Break Switch 200 A ( Xxvii ) Operating Handle Of Air Break Switch 200 A ( Xxviii ) Operating Leaver Of Air Break Switch 200 A ( Xxix ) Connector Of Air Break Switch 200 A ( Xxx ) Arching Horn Of Air Break Switch 200 A Vcb Repairing Item ( I ) Trip Coil Of 33Kv Vcb ( Ii ) Trip Coil Of 11Kv Vcb ( Iii ) Closing Coil Of 33Kv Vcb ( Iv ) Closing Coil Of 11Kv Vcb ( V ) Push Button Switch 5A ( Vi ) Test Terminal Block 5A ( Vii ) 33 Kv Indoor Current Transformers Of Ratio As Required Suitable For Metering And Protection. ( Viii ) 33 Kv Outdoor Current Transformers Of Ratio As Required Suitable For Metering And Protection. ( Ix ) 11 Kv Indoor Current Transformers Of Ratio As Required Suitable For Metering And Protection. ( X ) 11 Kv Outdoor Current Transformers Of Ratio As Required Suitable For Metering And Protection. ( Xi ) 33000 / 110 Volts Single Phase Voltage Transformer Indoor. ( Xii ) 33000 / 110 Volts Single Phase Voltage Transformer Outdoor. ( Xiii ) 11000 / 110 Volts Single Phase Voltage Transformer Indoor. ( Xiv ) 11000 / 110 Volts Single Phase Voltage Transformer Outdoor. ( Xv ) Flush Type Switchboard Mounting Pattern 96X96 Sq.Mm M.I. Voltmeter ( Xvi ) Voltmeter Phase Selector Switch. ( Xvii ) Indicating Lamps Coloured Red, Amber And Blue, White, Green, Etc. ( Xviii ) Auxiliary Switch Having Minimum Of 8 Contacts, 4 Normally Open And 4 Normally Closed ( Xix ) Flush Mounting Pattern 96X96 Sq.Mm M.I. Ammeter ( Xx ) Ammeter Selector Switch To Indicate Phase Current ( Xxi ) Over Current And Earth Fault Numerical Relay ( Xxii ) Automatic Door Illuminating Lamps With Switch ( Xxiii ) 240 V, 100 W, Ac Single Phase Anti / Condensation Heaters, With Thermostat ( 0-60 Deg. C ) And Switch. ( Xxiv ) Operation Counter For Vcb ( Xxv ) Bus Bar Spout Epoxy Casted R Phase Of 33Kv Indoor Vcb ( Xxvi ) Bus Bar Spout Epoxy Casted Y Phase Of 33Kv Indoor Vcb ( Xxvii ) Bus Bar Spout Epoxy Casted B Phase Of 33Kv Indoor Vcb ( Xxviii ) Circuit Spout Epoxy Casted Of 33Kv Indoor Vcb ( Xxix ) Housing For Vacuum Interrupter Of 33Kv Indoor Vcb ( Xxx ) Drive Insulator 33Kv Vcb ( Xxxi ) Release Coil Of 33Kv Indoor Vcb ( Xxxii ) Bus Bar Spout Epoxy Casted R Phase Of 11Kv Indoor Vcb ( Xxxiii ) Bus Bar Spout Epoxy Casted Y Phase Of 11Kv Indoor Vcb ( Xxxiv ) Bus Bar Spout Epoxy Casted B Phase Of 11Kv Indoor Vcb ( Xxxv ) Circuit Spout Epoxy Casted Of 11Kv Indoor Vcb ( Xxxvi ) Housing For Vacuum Interrupter Of 11Kv Indoor Vcb ( Xxxvii ) Drive Insulator Of 11Kv Vcb ( Xxxviii ) Release Coil Of 11Kv Indoor Vcb ( Xxxix ) Vacuum Interrupter Of 33Kv Outdoor Type ( Xl ) Vacuum Interrupter Of 33Kv Indoor Type ( Xli ) Vacuum Interrupter Of 11Kv Outdoor Type ( Xlii ) Vacuum Interrupter Of 11Kv Indoor Type ( Xliii ) Buzzer / Hooter ( Xliv ) T N C Switch M1680 Mrt Related Items ( I ) Fully Automatic Energy Meter Test Bench With 0.02 Class, 10 Position, For Testing Of 1 Ph & 3 Ph Energy Meters ( Ii ) 3 Ph Energy Meter Test Kit Field Testing Of 3 Ph Energy Meters Comprising Of Portable Reference Meter And Portable Power Source ( Iii ) 1 Ph Energy Meter Test Kit For Field Testing Of 1 Ph Energy Meter ( Iv ) Instrument Transformer ( Ct-Pt ) Test System ( V ) Dc Winding Resistance Measurement Test Kit Rating 25 A ( Vi ) Acdc Hipot Test Kit-5Kv ( Vii ) Transformer Turn Ratio Meter And Measurement Test Kit ( Viii ) Oil Breakdown Value ( Bdv ) Test Kit-80Kv ( Ix ) Transformer Oil Filtering Machine- 600 Lph ( X ) Earth Tester With All Necessary Accessories ( Xi ) Circuit Breaker Operational Analyzer ( Xii ) 3 Ph Relay Test Kit With All Necessary Accessories ( Xiii ) Digital Micro-Ohm Meter Measurement Test Kit ( Xiv ) Primary Injection Kit-1000 A With Relay Testing Facility ( Xv ) Ct Polarity Tester ( Xvi ) Tong Tester: 2000 A Ac / Dc ( Xvii ) Electro-Mechanical Tool Kit ( Xviii ) Hv Gloves ( Xix ) Capacitance Tan Delta Test Set For Transformer, Motor And Switchgear ( Xx ) Capacitance Tan Delta Test Set For Cables ( Xxi ) Vaccum Interrupter Tester ( Xxii ) Secondary Injection Kit ( Xxiii ) Digital Ht Earth Tester ( Xxiv ) 3 Ph Power Quality Analyser ( Xxv ) 05 Kv Insulation Tester ( Manual ) ( Xxvi ) 10 Kv Insulation Tester ( Motarized ) ( Xxvii ) Digital Clamp Meter; 20-1000A, 200 V Dc ( Xxviii ) Digital Clamp Meter; 20A ( 1Ma-20A ) ( Xxix ) Discharge Rod ( Xxx ) Thermal Imaging Camera M1681 Frp Fencing ( I ) Fiber Reinforced Plastic ( Frp ) Fencing For 11 / 0.433Kv, 63Kva Substation ( Ii ) Fiber Reinforced Plastic ( Frp ) Fencing For 11 / 0.433Kv, 100 Kva Substation ( Iii ) Fiber Reinforced Plastic ( Frp ) Fencing For 11 / 0.433Kv, 200 Kva Substation ( Iv ) Fiber Reinforced Plastic ( Frp ) Fencing For 11 / 0.433Kv, 315 Kva Substation ( V ) Fiber Reinforced Plastic ( Frp ) Fencing For 11 / 0.433Kv, 400Kva Substation ( Vi ) Fiber Reinforced Plastic ( Frp ) Fencing For 11 / 0.433Kv, 500 Kva Substation ( Vii ) Fiber Reinforced Plastic ( Frp ) Fencing For 11 / 0.433Kv, 630 Kva Substation ( Viii ) Fiber Reinforced Plastic ( Frp ) Fencing For 11 / 0.433Kv, 750 Kva Substation

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail