| Name of Work: Tender for Construction of foot over bridge and civil infrastructure at Polymer Terminal, PPMC | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Tender for Construction of foot over bridge and civil infrastructure at Polymer Terminal, PPMC | BI01010001010000000000000515BI0100001112 | ||
| 2 | 1.01 | Earth work in excavation by mechanical means (Hydraulic\nexcavator) / manual means in foundation trenches or drains\n(not exceeding 1.5 m in width or 10 sqm on plan) including\ndressing of sides and ramming of bottoms, lift up to 1.5 m,\nincluding getting out the excavated soil and disposal of surplus\nexcavated soil as directed, within a lead of 50 m. - All kinds of soil. | BI01010001010000000000000515BI0100001113 | 31 | M3 |
| 3 | 1.02 | Filling available excavated earth (excluding rock) in trenches,\nplinth, sides of foundations etc. in layers not exceeding 20cm\nin depth, consolidating each deposited layer by ramming and\nwatering, lead up to 50 m and lift up to 1.5 m.\n | BI01010001010000000000000515BI0100001113 | 20 | M3 |
| 4 | 1.03 | Demolishing R.C.C. work manually/ by mechanical means\nincluding stacking of steel bars and disposal of unserviceable\nmaterial within 50 metres lead as per direction of Engineer - in-\ncharge.\n | BI01010001010000000000000515BI0100001113 | 10 | M3 |
| 5 | 1.04 | Demolishing cement concrete manually/ by mechanical means\nincluding disposal of material within 50 metres lead as per\ndirection of Engineer - in - charge. - Nominal concrete 1:3:6 or richer mix (i/c equivalent design\nmix)\n | BI01010001010000000000000515BI0100001113 | 15 | M3 |
| 6 | 1.05 | Demolishing brick work manually/ by mechanical means\nincluding stacking of serviceable material and disposal of\nunserviceable material within 50 metres lead as per direction\nof Engineer-in-charge. - In cement mortar | BI01010001010000000000000515BI0100001113 | 15 | M3 |
| 7 | 1.06 | Providing and laying in position cement concrete of specified\ngrade excluding the cost of centring and shuttering - All work\nup to plinth level : - 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20\nmm nominal size)\n | BI01010001010000000000000515BI0100001113 | 5 | M3 |
| 8 | 1.07 | Providing and laying in position cement concrete of specified\ngrade excluding the cost of centring and shuttering - All work\nup to plinth level : - 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate\n40 mm nominal size)\n | BI01010001010000000000000515BI0100001113 | 1 | M3 |
| 9 | 1.08 | Brick work with common burnt clay F.P.S. (non modular)\nbricks of class designation 7.5 in foundation and plinth in: -- Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001113 | 5 | M3 |
| 10 | 1.09 | CEMENT PLASTER (IN FINE SAND) : 12 mm cement plaster of mix : - 1:6 (1 cement: 6 fine sand) | BI01010001010000000000000515BI0100001113 | 10.52 | M2 |
| 11 | 1.1 | CEMENT PLASTER (IN FINE SAND) : 15 mm cement plaster on the rough side of single or half brick\nwall of mix : -- 1:6 (1 cement: 6 fine sand) | BI01010001010000000000000515BI0100001113 | 5 | M2 |
| 12 | 1.11 | Applying priming coat : - With ready mixed red oxide zinc chromate primer of approved\nbrand and manufacture on steel galvanised iron/steel works\n | BI01010001010000000000000515BI0100001113 | 150 | M2 |
| 13 | 1.12 | Painting with synthetic enamel paint of approved brand and\nmanufacture to give an even shade : - Two or more coats on new work. | BI01010001010000000000000515BI0100001113 | 150 | M2 |
| 14 | 1.13 | Applying one coat of water thinnable cement primer of\napproved brand and manufacture on wall surface : - Water thinnable cement primer. | BI01010001010000000000000515BI0100001113 | 531 | M2 |
| 15 | 1.14 | Finishing walls with water proofing cement paint of required\nshade : -- New work (Two or more coats applied @ 3.84 kg/10 sqm). | BI01010001010000000000000515BI0100001113 | 11 | M2 |
| 16 | 1.15 | Carriage of lime, moorum, building rubbish and debris\nincluding refractory/ insulation debris etc. by mechanical\ntransport for following leads or part thereof including\nloading, unloading and stacking all complete as per the\ndirection of the Engineer-in-Charge. - Lead beyond 4 km. but upto 5 km. | BI01010001010000000000000515BI0100001113 | 20 | M3 |
| 17 | 1.16 | Carriage of lime, moorum, building rubbish and debris\nincluding refractory/ insulation debris etc. by mechanical\ntransport for following leads or part thereof including\nloading, unloading and stacking all complete as per the\ndirection of the Engineer-in-Charge. - Extra for lead beyond 5 Kms. and upto 10 Kms. (Per\nKm.)\n | BI01010001010000000000000515BI0100001113 | 20 | M3 |
| 18 | 1.17 | FORM WORK : Centering and shuttering including strutting, propping etc. and\nremoval of form for : - Foundations, footings, bases of columns, etc. for mass\nconcrete.\n | BI01010001010000000000000515BI0100001113 | 21.02 | M2 |
| 19 | 1.18 | FORM WORK : Centering and shuttering including strutting, propping etc. and\nremoval of form for : - Columns, Pillars, Piers, Abutments, Posts and Struts. | BI01010001010000000000000515BI0100001113 | 5 | M2 |
| 20 | 1.19 | REINFORCED CEMENT CONCRETE WORK : CAST-IN-SITU : Providing and laying in position specified grade of reinforced\ncement concrete excluding the cost of centering, shuttering,\nfinishing and reinforcement - All work up to plinth level : - 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone\naggregate 20 mm nominal size)\n | BI01010001010000000000000515BI0100001113 | 49.3 | M3 |
| 21 | 1.2 | Steel work welded in built up sections/ framed work including\ncutting, hoisting, fixing in position and applying a priming coat\nof approved steel primer using structural steel etc. as required. - In gratings, frames, guard bar, ladder, railings, brackets, gates\n and similar works.\n | BI01010001010000000000000515BI0100001113 | 5130 | KG |
| 22 | 1.21 | Providing and fixing mild steel round holding down bolts with\n nuts and washer plates complete.\n | BI01010001010000000000000515BI0100001113 | 78 | KG |
| 23 | 1.22 | STEEL REINFORCEMENT : Steel reinforcement for R.C.C. work including straightening,\ncutting, bending, placing in position and binding all complete\nup to plinth level. - Thermo-Mechanically Treated bars. | BI01010001010000000000000515BI0100001113 | 9120.21 | KG |
| 24 | 1.23 | Supplying and filling in plinth with Jamuna sand under floors,\nincluding watering, ramming, consolidating and dressing\ncomplete. \n | BI01010001010000000000000515BI0100001113 | 2.5 | M2 |
| 25 | 1.24 | Providing and laying 75mm thick compacted bed of dry brick\naggregate of 40mm thick nominal size including spreading,\nwell ramming, consolidating and grouting with jamuna sand\nincluding finishing smooth etc. complete as per direction of\nEngineer-in-charge.\n | BI01010001010000000000000515BI0100001113 | 17 | M2 |
| 26 | 1.25 | Supplying and stacking at site. - Good earth. | BI01010001010000000000000515BI0100001113 | 43.8 | cum |
| 27 | 1.26 | Providing and laying in position cement concrete of specified\ngrade excluding the cost of centring and shuttering - All work\nup to plinth level : - 1:3:6(1CEMENT:3 COARSE SAND :6 GRADED STONE AGGREGATE 20 MM NOMINAL SIZE). | BI01010001010000000000000515BI0100001113 | 11 | M3 |
| 28 | 1.27 | Brick work with common burnt clay F.P.S. (non modular)\nbricks of class designation 7.5 in foundation and plinth in: - Cement mortar 1:4 (1 cement : 4 coarse sand) | BI01010001010000000000000515BI0100001113 | 41 | M3 |
| 29 | 1.28 | Brick work with common burnt clay machine moulded\nperforated bricks of class designation 12.5 conforming to IS:\n2222 -1991 in superstructure above plinth level up to floor five\nlevel in cement mortar 1:6 (1 cement : 6 coarse sand) : - 1:6 CEMENT MORTAR | BI01010001010000000000000515BI0100001113 | 36 | M3 |
| 30 | 1.29 | Half brick masonry with common burnt clay F.P.S. (non\nmodular) bricks of class designation 7.5 in foundations and\nplinth in. - 1:4 CEMENT MORTAR | BI01010001010000000000000515BI0100001113 | 4 | M2 |
| 31 | 1.3 | Half brick masonry with common burnt clay F.P.S. (non\nmodular) bricks of class designation 7.5 in superstructure\nabove plinth level up to floor V level. - 1:4 CEMENT MORTAR | BI01010001010000000000000515BI0100001113 | 20 | M2 |
| 32 | 1.31 | 12MM CEMENT PLASTER - 1:4 (1 CEMENT : 4 FINE SAND) | BI01010001010000000000000515BI0100001113 | 200 | M2 |
| 33 | 1.32 | 15 mm cement plaster on the rough side of single or half brick\nwall of mix : - 1:4 (1 CEMENT : 4 FINE SAND) | BI01010001010000000000000515BI0100001113 | 200 | M2 |
| 34 | 1.33 | 6 mm cement plaster of mix - 1:3 6MM PLASTER IN CELLING | BI01010001010000000000000515BI0100001113 | 106.47 | SQM |
| 35 | 1.34 | Structural steel work in single section fixed with or without\nconnecting plate including cutting, hoisting, fixing in position\nand applying a priming coat of approved steel primer all\ncomplete.\n | BI01010001010000000000000515BI0100001113 | 108.08 | KG |
| 36 | 1.35 | Structural steel work riveted, bolted or welded in built up\nsections, trusses and framed work, including cutting, hoisting,\nfixing in position and applying a priming coat of approved steel\nprimer all complete.\n | BI01010001010000000000000515BI0100001113 | 1384 | KG |
| 37 | 1.36 | LETTERING WITH BLACK JAPAN PAINT OF APPROVED BRAND AND MANUFACTURE | BI01010001010000000000000515BI0100001113 | 1000 | Per letter per cm height |
| 38 | 1.37 | Providing and fixing ISI marked flush door shutters conforming\nto IS: 2202 (Part I) non-decorative type, core of block board\nconstruction with frame of 1st class hard wood and well\nmatched commercial 3 ply veneering with vertical grains or\ncross bands and face veneers on both faces of shutters : - 35 mm thick including ISI marked Stainless Steel butt hinges\nwith necessary screws.\n | BI01010001010000000000000515BI0100001113 | 18.1 | M2 |
| 39 | 1.38 | Providing and fixing M.S. grills of required pattern in frames of\nwindows etc. with M.S. flats, square or round bars etc.\nincluding priming coat with approved steel primer all complete. - Providing and fixing M.S. grills of required pattern in frames of\nwindows etc. with M.S. flats, square or round bars etc.\nincluding priming coat with approved steel primer all complete. - Fixed to steel windows by welding. | BI01010001010000000000000515BI0100001113 | 45 | KG |
| 40 | 1.39 | Providing and fixing bright finished brass 100 mm mortice latch\nand lock with 6 levers and a pair of lever handles with\nnecessary screws etc. complete (best make of approved\nquality). \n | BI01010001010000000000000515BI0100001113 | 12 | EA |
| 41 | 1.4 | Providing and fixing aluminium die cast body tubular type\nuniversal hydraulic door closer (having brand logo with ISI, IS :\n3564, embossed on the body, door weight up to 35 kg and\ndoor width up to 700 mm) with necessary accessories and\nscrews etc. complete.\n | BI01010001010000000000000515BI0100001113 | 10 | EA |
| 42 | 1.41 | Providing and fixing aluminium sliding door bolts ISI marked\nanodised (anodic coating not less than grade AC 10 as per IS :\n1868) transparent or dyed to required colour or shade with nuts\nand screws etc. complete : - 300X16 MM | BI01010001010000000000000515BI0100001113 | 10 | EA |
| 43 | 1.42 | Providing and fixing aluminium tower bolts ISI marked\nanodised (anodic coating not less than grade AC 10 as per IS :\n1868 ) transparent or dyed to required colour or shade with\nnecessary screws etc. complete : - 200X10 MM | BI01010001010000000000000515BI0100001113 | 18 | EA |
| 44 | 1.43 | Providing and fixing aluminium tower bolts ISI marked\nanodised (anodic coating not less than grade AC 10 as per IS :\n1868 ) transparent or dyed to required colour or shade with\nnecessary screws etc. complete : - 150X10 MM | BI01010001010000000000000515BI0100001113 | 18 | EA |
| 45 | 1.44 | Providing and fixing aluminium handles ISI marked anodised\n(anodic coating not less than grade AC 10 as per IS : 1868)\ntransparent or dyed to required colour or shade with necessary\nscrews etc. complete : - 125 MM | BI01010001010000000000000515BI0100001113 | 26 | EA |
| 46 | 1.45 | Providing and fixing aluminium handles ISI marked anodised\n(anodic coating not less than grade AC 10 as per IS : 1868)\ntransparent or dyed to required colour or shade with necessary\nscrews etc. complete : - 100 MM | BI01010001010000000000000515BI0100001113 | 10 | EA |
| 47 | 1.46 | Providing and fixing aluminium hanging floor door stopper ISI\nmarked anodised (anodic coating not less than grade AC 10 as\nper IS : 1868) transparent or dyed to required colour and\nshade with necessary screws etc. complete. - SINGLE RUBBER STOPPER | BI01010001010000000000000515BI0100001113 | 10 | EA |
| 48 | 1.47 | Providing and fixing aluminium hanging floor door stopper ISI\nmarked anodised (anodic coating not less than grade AC 10 as\nper IS : 1868) transparent or dyed to required colour and\nshade with necessary screws etc. complete. - TWIN RUBBER STOPPER | BI01010001010000000000000515BI0100001113 | 10 | EA |
| 49 | 1.48 | Providing and fixing pressed steel door frames conforming to\nIS: 4351 manufactured from commercial mild steel sheet of\n1.60 mm thickness including hinges, jamb, lock jamb, bead\nand if required angle threshold of mild steel angle of section\n50x25mm, or base ties of 1.60 mm pressed mild steel welded\nor rigidly fixed together by mechanical means, including M.S.\npressed butt hinges, 2.5mm thick with mortar guards, lock\nstrike-plate and shock absorbers as specified and applying a\ncoat of approved steel primer after pre-treatment of the\nsurface as directed by Engineer-in-charge: - PROFILE C - Fixing with adjustable lugs with split end tail to each jamb. | BI01010001010000000000000515BI0100001113 | 50 | M |
| 50 | 1.49 | Applying priming coats with primer of approved brand and\nmanufacture, having low VOC (Volatile Organic Compound )\ncontent. - With ready mixed pink or grey primer on wood work (hard and\nsoft wood) having VOC content less than 50 grams/ litre.\n | BI01010001010000000000000515BI0100001113 | 90 | M2 |
| 51 | 1.5 | Wall painting with acrylic emulsion paint of approved brand\nand manufacture to give an even shade: - Two or more coats on new work. | BI01010001010000000000000515BI0100001113 | 520 | M2 |
| 52 | 1.51 | Painting with synthetic enamel paint, having VOC (Volatile\nOrganic Compound) content less than 150 grams/ litre, of\napproved brand and manufacture, including applying additional\ncoats wherever required to achieve even shade and colour. - Two coats. | BI01010001010000000000000515BI0100001113 | 60 | M2 |
| 53 | 1.52 | Providing and applying white cement based putty of average\nthickness 1 mm, of approved brand and manufacturer, over\nthe plastered wall surface to prepare the surface even and\nsmooth complete. \n | BI01010001010000000000000515BI0100001113 | 520 | SQM |
| 54 | 1.53 | Providing and fixing white vitreous china pedestal type\n(European type/ wash down type) water closet pan.\n | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 55 | 1.54 | Providing and fixing P.V.C. low level flushing cistern with\nmanually controlled device (handle lever) conforming to IS :\n7231, with all fittings and fixtures complete. - 10 LITRE CAPACITY-WHITE | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 56 | 1.55 | Providing and fixing white vitreous china wash basin including\nmaking all connections but excluding the cost of fittings : - Flat back wash basin of size 550x400mm. | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 57 | 1.56 | PTMT PILLAR COCK | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 58 | 1.57 | Providing and fixing white vitreous china flat back or wall\ncorner type lipped front urinal basin of 430x260x350mm or\n340x410x265mm sizes respectively.\n | BI01010001010000000000000515BI0100001113 | 1 | EA |
| 59 | 1.58 | Providing and fixing ball valve (brass) of approved quality, High\nor low pressure, with plastic floats complete : - 15 MM NOMINAL BORE | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 60 | 1.59 | Providing and fixing ball valve (brass) of approved quality, High\nor low pressure, with plastic floats complete : - 20 MM NOMINAL BORE | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 61 | 1.6 | Providing and fixing P.V.C. waste pipe for sink or wash basin\nincluding P.V.C. waste fittings complete. - 32 MM DIA SEMI RIGID PIPE | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 62 | 1.61 | Providing and fixing P.V.C. waste pipe for sink or wash basin\nincluding P.V.C. waste fittings complete. - 40 MM DIA SEMI RIGID PIPE | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 63 | 1.62 | Providing and fixing 100 mm sand cast Iron grating for gully\ntrap.\n | BI01010001010000000000000515BI0100001113 | 5 | EA |
| 64 | 1.63 | Providing and fixing 600x450 mm beveled edge mirror of\nsuperior glass (of approved quality) complete with 6 mm thick\nhard board ground fixed to wooden cleats with C.P. brass\nscrews and washers complete.\n | BI01010001010000000000000515BI0100001113 | 4 | EA |
| 65 | 1.64 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)\npipes, having thermal stability for hot & cold water supply\nincluding all CPVC plain & brass threaded fittings i/c fixing the\npipe with clamps at 1.00 m spacing. This includes jointing of\npipes & fittings with one step CPVC solvent cement and the\ncost of cutting chases and making good the same including\ntesting of joints complete as per direction of Engineer in\nCharge.\nConcealed work including cutting chases and making good the\nwalls etc. - 15 MM DIA NOMINAL BORE | BI01010001010000000000000515BI0100001113 | 25 | M |
| 66 | 1.65 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)\npipes, having thermal stability for hot & cold water supply\nincluding all CPVC plain & brass threaded fittings i/c fixing the\npipe with clamps at 1.00 m spacing. This includes jointing of\npipes & fittings with one step CPVC solvent cement and the\ncost of cutting chases and making good the same including\ntesting of joints complete as per direction of Engineer in\nCharge.\nConcealed work including cutting chases and making good the\nwalls etc. - 20 MM DIA NOMINAL BORE | BI01010001010000000000000515BI0100001113 | 10 | M |
| 67 | 1.66 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)\npipes, having thermal stability for hot & cold water supply\nincluding all CPVC plain & brass threaded fittings including\nfixing the pipe with clamps at 1.00 m spacing. This includes\njointing of pipes & fittings with one step CPVC solvent cement\nand testing of joints complete as per direction of Engineer in\nCharge.\nInternal work - Exposed on wall - 15 MM DIA. NOMINAL BORE | BI01010001010000000000000515BI0100001113 | 20 | M |
| 68 | 1.67 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)\npipes, having thermal stability for hot & cold water supply\nincluding all CPVC plain & brass threaded fittings including\nfixing the pipe with clamps at 1.00 m spacing. This includes\njointing of pipes & fittings with one step CPVC solvent cement\nand testing of joints complete as per direction of Engineer in\nCharge.\nInternal work - Exposed on wall - 20 MM DIA. NOMINAL BORE | BI01010001010000000000000515BI0100001113 | 20 | M |
| 69 | 1.68 | Providing and fixing brass bib cock of approved quality : - 15 MM NOMINAL BORE | BI01010001010000000000000515BI0100001113 | 4 | EA |
| 70 | 1.69 | Providing and fixing brass stop cock of approved quality : - 15 MM NOMINAL BORE | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 71 | 1.7 | Providing and fixing uplasticised PVC connection pipe with\nbrass unions : - Providing and fixing uplasticised PVC connection pipe with\nbrass unions : - 15 MM NOMINAL BORE, 45 CM LENGTH | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 72 | 1.71 | Providing and fixing uplasticised PVC connection pipe with\nbrass unions : - Providing and fixing uplasticised PVC connection pipe with\nbrass unions : - 20 MM NOMINAL BORE, 45 CM LENGTH | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 73 | 1.72 | Providing and placing on terrace (at all floor levels)\npolyethylene water storage tank ISI : 12701 marked with cover\nand suitable locking arrangement and making necessary holes\nfor inlet, outlet and overflow pipes but without fittings and the\nbase support for tank. \n | BI01010001010000000000000515BI0100001113 | 1000 | L |
| 74 | 1.73 | Providing and fixing PTMT Ball cock of approved quality,\ncolour and make complete with Epoxy coated aluminium rod\nwith L.P./ H.P.H.D. plastic ball. - 15 MM BORE, 105MM LONG WT 138GMS | BI01010001010000000000000515BI0100001113 | 1 | EA |
| 75 | 1.74 | Providing and fixing PTMT Ball cock of approved quality,\ncolour and make complete with Epoxy coated aluminium rod\nwith L.P./ H.P.H.D. plastic ball. - 20 MM BORE, 120MM LONG WT 198GMS | BI01010001010000000000000515BI0100001113 | 1 | EA |
| 76 | 1.75 | Providing and fixing C.P. brass angle valve for basin mixer and\ngeyser points of approved quality conforming to IS:8931 a) 15\nmm nominal bore - 15MM NOMINAL BORE | BI01010001010000000000000515BI0100001113 | 5 | EA |
| 77 | 1.76 | Providing and fixing Ist quality ceramic glazed wall tiles\nconforming to IS : 15622 (thickness to be specified by the\nmanufacturer) of approved make in all colours, shades except\nburgundy, bottle green, black of any size as approved by\nEngineer-in-Charge, in skirting, risers of steps and dados over\n12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse\nsand) and jointing with grey cement slurry @ 3.3kg per sqm\nincluding pointing in white cement mixed with pigment of\nmatching shade complete.\n | BI01010001010000000000000515BI0100001113 | 22.83 | M2 |
| 78 | 1.77 | Providing and laying vitrified floor tiles in different sizes\n(thickness to be specified by the manufacturer) with water\nabsorption's less than 0.08% and conforming to IS : 15622 of\napproved make in all colours and shades, laid on 20mm thick\ncement mortar 1:4 (1 cement : 4 coarse sand) including\ngrouting the joints with white cement and matching pigments\netc., complete. - 600X600 VERTRIFIED TILE | BI01010001010000000000000515BI0100001113 | 73 | M2 |
| 79 | 1.78 | PROVIDING AND FIXING ON WALL FACE UNPLASTICISED RIGID PVC RAIN WATER PIPES CONFORMING TO IS:13592 TYPE AINCLUDING JOINTING WITH SEAL RING CONFORMING TO IS:5382 LEAVING 10MM GAP FORTHERMAL EXPANSION.(I) SINGLE SOCKETED PIPES. - 75 MM DIAMETER | BI01010001010000000000000515BI0100001113 | 15 | M |
| 80 | 1.79 | PROVIDING AND FIXING ON WALL FACE UNPLASTICISED RIGID PVC RAIN WATER PIPES CONFORMING TO IS:13592 TYPE AINCLUDING JOINTING WITH SEAL RING CONFORMING TO IS:5382 LEAVING 10MM GAP FORTHERMAL EXPANSION.(I) SINGLE SOCKETED PIPES. - 110 MM DIAMETER | BI01010001010000000000000515BI0100001113 | 30 | M |
| 81 | 1.8 | PROVIDING AND FIXING ON WALL FACE UNPLASTICISED-PVC MOULDED FITTINGS/ACCESSORIES FOR UNPLASTICISED RIGID PVC RAINWATE RPIPES CONFORMING TO IS:13592 TYPE A INCLUDING JOINTING WITH SEAL RING CONFORMING TO IS:5382LEAVING 10MM GAP FOR THERMAL EXPANSION. COUPLER - 75 MM | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 82 | 1.81 | PROVIDING AND FIXING ON WALL FACE UNPLASTICISED-PVC MOULDED FITTINGS/ACCESSORIES FOR UNPLASTICISED RIGID PVC RAINWATE RPIPES CONFORMING TO IS:13592 TYPE A INCLUDING JOINTING WITH SEAL RING CONFORMING TO IS:5382LEAVING 10MM GAP FOR THERMAL EXPANSION. COUPLER - 110 MM | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 83 | 1.82 | PROVIDING AND FIXING ON WALL FACE UNPLASTICISED-PVC MOULDED FITTINGS/ACCESSORIES FOR UNPLASTICISED RIGID PVC RAINWATE RPIPES CONFORMING TO IS:13592 TYPE A INCLUDING JOINTING WITH SEAL RING CONFORMING TO IS:5382LEAVING 10MM GAP FOR THERMAL EXPANSION. COUPLER - SINGLE PUSHFIT COUPLER 75 MM | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 84 | 1.83 | PROVIDING AND FIXING ON WALL FACE UNPLASTICISED-PVC MOULDED FITTINGS/ACCESSORIES FOR UNPLASTICISED RIGID PVC RAINWATE RPIPES CONFORMING TO IS:13592 TYPE A INCLUDING JOINTING WITH SEAL RING CONFORMING TO IS:5382LEAVING 10MM GAP FOR THERMAL EXPANSION. COUPLER - SINGLE PUSHFIT COUPLER 110 MM | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 85 | 1.84 | PROVIDING AND FIXING ON WALL FACE UNPLASTICISED-PVC MOULDED FITTINGS/ACCESSORIES FOR UNPLASTICISED RIGID PVC RAINWATE RPIPES CONFORMING TO IS:13592 TYPE A INCLUDING JOINTING WITH SEAL RING CONFORMING TO IS:5382LEAVING 10MM GAP FOR THERMAL EXPANSION. COUPLER - SINGLE TEE WITH DOOR 75X75X75 MM | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 86 | 1.85 | PROVIDING AND FIXING ON WALL FACE UNPLASTICISED-PVC MOULDED FITTINGS/ACCESSORIES FOR UNPLASTICISED RIGID PVC RAINWATE RPIPES CONFORMING TO IS:13592 TYPE A INCLUDING JOINTING WITH SEAL RING CONFORMING TO IS:5382LEAVING 10MM GAP FOR THERMAL EXPANSION. COUPLER - SINGLE TEE WITH DOOR 110X110X110 MM | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 87 | 1.86 | PROVIDING AND FIXING ON WALL FACE UNPLASTICISED-PVC MOULDED FITTINGS/ACCESSORIES FOR UNPLASTICISED RIGID PVC RAINWATE RPIPES CONFORMING TO IS:13592 TYPE A INCLUDING JOINTING WITH SEAL RING CONFORMING TO IS:5382LEAVING 10MM GAP FOR THERMAL EXPANSION. COUPLER - SINGLE TEE WITHOUT DOOR 75X75X75 MM | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 88 | 1.87 | PROVIDING AND FIXING ON WALL FACE UNPLASTICISED-PVC MOULDED FITTINGS/ACCESSORIES FOR UNPLASTICISED RIGID PVC RAINWATE RPIPES CONFORMING TO IS:13592 TYPE A INCLUDING JOINTING WITH SEAL RING CONFORMING TO IS:5382LEAVING 10MM GAP FOR THERMAL EXPANSION. COUPLER - SINGLE TEE WITHOUT DOOR 110X110X110 MM | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 89 | 1.88 | PROVIDING AND FIXING ON WALL FACE UNPLASTICISED-PVC MOULDED FITTINGS/ACCESSORIES FOR UNPLASTICISED RIGID PVC RAINWATE RPIPES CONFORMING TO IS:13592 TYPE A INCLUDING JOINTING WITH SEAL RING CONFORMING TO IS:5382LEAVING 10MM GAP FOR THERMAL EXPANSION. COUPLER - BEND 87.5° 75 MM | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 90 | 1.89 | PROVIDING AND FIXING ON WALL FACE UNPLASTICISED-PVC MOULDED FITTINGS/ACCESSORIES FOR UNPLASTICISED RIGID PVC RAINWATE RPIPES CONFORMING TO IS:13592 TYPE A INCLUDING JOINTING WITH SEAL RING CONFORMING TO IS:5382LEAVING 10MM GAP FOR THERMAL EXPANSION. COUPLER - BEND 87.5° 110 MM | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 91 | 1.9 | PROVIDING AND FIXING ON WALL FACE UNPLASTICISED-PVC MOULDED FITTINGS/ACCESSORIES FOR UNPLASTICISED RIGID PVC RAINWATE RPIPES CONFORMING TO IS:13592 TYPE A INCLUDING JOINTING WITH SEAL RING CONFORMING TO IS:5382LEAVING 10MM GAP FOR THERMAL EXPANSION. COUPLER - SHOE (PLAIN) 75 MM | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 92 | 1.91 | PROVIDING AND FIXING ON WALL FACE UNPLASTICISED-PVC MOULDED FITTINGS/ACCESSORIES FOR UNPLASTICISED RIGID PVC RAINWATE RPIPES CONFORMING TO IS:13592 TYPE A INCLUDING JOINTING WITH SEAL RING CONFORMING TO IS:5382LEAVING 10MM GAP FOR THERMAL EXPANSION. COUPLER - SHOE (PLAIN) 110 MM | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 93 | 1.92 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls up to 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing\ncompound conforming to IS : 2645 and approved by Engineer- in-charge to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of\nwalls and slabsc) After two days of proper curing applying a second coat of\ncement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep.\ne) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and\nspecified by the Engineer-in-Charge : - WITH AVERAGE THICKNESS OF 120MM AND MINIMUM THICKNESS AT KHURRA AS 65 MM | BI01010001010000000000000515BI0100001113 | 73 | SQM |
| 94 | 1.93 | Providing and fixing aluminium work for doors, windows,\nventilators and partitions with extruded built up standard\ntubular sections/ appropriate Z sections and other sections of\napproved make conforming to IS: 733 and IS: 1285, fixing with\ndash fasteners of required dia and size, including necessary\nfilling up the gaps at junctions, i.e. at top, bottom and sides\nwith required EPDM rubber/ neoprene gasket etc. Aluminium\nsections shall be smooth, rust free, straight, mitred and jointed\nmechanically wherever required including cleat angle,\nAluminium snap beading for glazing / paneling, C.P. brass /\nstainless steel screws, all complete as per architectural\ndrawings and the directions of Engineer-in-charge. (Glazing,\npaneling and dash fasteners to be paid for separately) : - Powder coated aluminium (minimum thickness of powder\ncoating 50 micron)\n | BI01010001010000000000000515BI0100001113 | 290 | kg |
| 95 | 1.94 | Toughened glass 12 mm thickness | BI01010001010000000000000515BI0100001113 | 44 | sqm |
| 96 | 1.95 | Providing and fixing 18mm thick gang saw cut mirror polished\npremoulded and prepolished) machine cut for kitchen\nplatforms, vanity counters, window sills, facias and similar\nlocations of required size of approved shade, colour and\ntexture laid over 20mm thick base cement mortar 1:4 (1\ncement : 4 coarse sand) with joints treated with white cement,\nmixed with matching pigment, epoxy touch ups, including\nrubbing, curing, moulding and polishing to edges to give high\ngloss finish etc. complete at all levels.\nGranite of any colour and shade - Area of slab over 0.50 sqm. | BI01010001010000000000000515BI0100001113 | 13.8 | sqm |
| 97 | 1.96 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.\n(Cost of aluminium snap beading shall be paid in basic item): - With float glass panes of 5.50 mm thickness | BI01010001010000000000000515BI0100001113 | 10 | sqm |
| 98 | 1.97 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for\nseparately). - Second class teak wood | BI01010001010000000000000515BI0100001113 | 0.12 | cum |
| 99 | 1.98 | Particle Board 12 mm thick - Plain particle board flat pressed, 3 layer or graded wood\nparticle board medium density Grade I, IS : 3087 marked.\n | BI01010001010000000000000515BI0100001113 | 10 | sqm |
| 100 | 1.99 | Providing and fixing magnetic catcher in cupboard / ward robe\nshutters including fixing with necessary screws etc. complete\n(Best make of approved quality. - Triple strip vertical type. | BI01010001010000000000000515BI0100001113 | 24 | EA |
| 101 | 2 | With ready mixed pink or Grey primer of approved brand and\nmanufacture on wood work (hard and soft wood) | BI01010001010000000000000515BI0100001113 | 10.56 | sqm |
| 102 | 2.01 | Providing and fixing ISI marked oxidised M.S. handles\nconforming to IS:4992 with necessary screws etc. complete : - 100 mm | BI01010001010000000000000515BI0100001113 | 8 | Each |
| 103 | 2.02 | Providing and applying two coats of fire retardant paint on\ncleaned wood/ply surface @ 3.5 sqm per litre per coat\nincluding preparation of base surface as per recommendations\nof manufacturer to make the surface fire retardant.\n | BI01010001010000000000000515BI0100001113 | 10.56 | sqm |
| 104 | 2.03 | Providing and laying in position cement concrete of specified\ngrade excluding the cost of centring and shuttering - All work\nup to plinth level : - 1:4:8 (1 cement : 3coarse sand: 6 GRADE STONE) | BI01010001010000000000000515BI0100001113 | 2 | M3 |
| 105 | 2.04 | PROVIDING AND FIXING PRECOATED GALVANISED IRON PROFILE SHEETS (SIZE,SHAPE AND PITCH OF CORRUGATION AS APPROVED BY ENGINEER-IN-CHARGE) | BI01010001010000000000000515BI0100001113 | 84 | M2 |
| 106 | 2.05 | ITC OF FLOURESCENT LIGHT FITTINGS INCLUDING SUPPLY OF CONNECTING COPPER CABLE - Installation, testing and commissioning of prewired, flourescent light fittings of all types complete will all accessories and tubes etc. directly ceiling / wall including connections with 1.5 sqmm, PVC insulated, copper\nconductor, single core cable etc.as required.\n | BI01010001010000000000000515BI0100001113 | 20 | EA |
| 107 | 2.06 | 4 FT LED TUBE LIGHTS ( 18 W ) | BI01010001010000000000000515BI0100001113 | 20 | EA |
| 108 | 2.07 | Supplying and fixing of following way, prewired single pole and neutral, sheet steel, MCB consumer unit, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, hinged front acrylic cover for the MCB knobs, detachable gland plate, interconnections, including painting, earthing etc. as required. - MCB CONSUMER ( 2+8 way ) | BI01010001010000000000000515BI0100001113 | 4 | EA |
| 109 | 2.08 | Supplying and fixing following rating, double pole, (single phase neutral), 240 volts, residual current circuit breaker (RCCB), ISI marked, having a sensitivity current indicated miliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.\nNote: ISI marked RCCB shall be used.\n - DOUBLE POLE RCCB (32 AMP ) | BI01010001010000000000000515BI0100001113 | 4 | EA |
| 110 | 2.09 | Supplying and fixing 5 amps. To 32 amps. Rating, 240/ 415 volts, 50Hz, 10KA 'G' series, miniature circuit breaker (suitable for motor and other inductive loads and conforming to IS 8828: 1996, IEC 60898: 2002) of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Note: ISI marked MCBs of Havells / Loadster / Indo Kopp make shall be used. - 5 A TO 32 A 'G' SERIES MCB ( SINGLE POLE ) | BI01010001010000000000000515BI0100001113 | 8 | EA |
| 111 | 2.1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm ISI marked FRLS PVC insulated copper conductor single core cable in recessed steel conduit (20mm), with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.\nNote: Only ISI marked conduits, cables, switches and socket outlets shall be used. - SHORT POINT UPTO 3M | BI01010001010000000000000515BI0100001113 | 20 | EA |
| 112 | 2.11 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm ISI marked FRLS PVC insulated copper conductor single core cable in recessed steel conduit (20mm), with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.\nNote: Only ISI marked conduits, cables, switches and socket outlets shall be used. - MEDIUM POINT UPTO 3M TO 6M | BI01010001010000000000000515BI0100001113 | 20 | EA |
| 113 | 2.12 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm ISI marked FRLS PVC insulated copper conductor single core cable in recessed steel conduit (20mm), with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.\nNote: Only ISI marked conduits, cables, switches and socket outlets shall be used. - LONG POINT UPTO 10M | BI01010001010000000000000515BI0100001113 | 6 | EA |
| 114 | 2.13 | Supply, fixing and connection of 250 V below given mosaic wiring accessories of M/s MDS or approved equivalent inlcuding supplying and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the\nEngineer-in-Charge. - 6 AMPS-1 WAY-SP-1 MODULE SWITCHES | BI01010001010000000000000515BI0100001113 | 24 | EA |
| 115 | 2.14 | Supply, fixing and connection of 250 V below given mosaic wiring accessories of M/s MDS or approved equivalent inlcuding supplying and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the\nEngineer-in-Charge. - 16 AMPS-1 WAY-SP-1 MODULE SWITCHES | BI01010001010000000000000515BI0100001113 | 20 | EA |
| 116 | 2.15 | Supply, fixing and connection of 250 V below given mosaic wiring accessories of M/s MDS or approved equivalent inlcuding supplying and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the\nEngineer-in-Charge. - 100 WATTS 2 MODULE STEP REGULATOR | BI01010001010000000000000515BI0100001113 | 6 | EA |
| 117 | 2.16 | Supply, fixing and connection of 250 V below given mosaic wiring accessories of M/s MDS or approved equivalent inlcuding supplying and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the\nEngineer-in-Charge. - 6/16 AMPS-3 PINS COMBINED 3 MODULE SHUTTERRED SOCKET | BI01010001010000000000000515BI0100001113 | 12 | EA |
| 118 | 2.17 | Supply, fixing and connection of 250 V below given mosaic wiring accessories of M/s MDS or approved equivalent inlcuding supplying and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the\nEngineer-in-Charge. - 6 AMPS-2/3 PINS COMBINED 2 MODULE SHUTTERRED SOCKET | BI01010001010000000000000515BI0100001113 | 20 | EA |
| 119 | 2.18 | Supply, fixing and connection of 250 V below given mosaic wiring accessories of M/s MDS or approved equivalent inlcuding supplying and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the\nEngineer-in-Charge. - 1 MODULE BLANKING PLATE | BI01010001010000000000000515BI0100001113 | 10 | EA |
| 120 | 2.19 | Supply and fixing of below given white cover plate with frame for mosaic wiring accessories of M/s MDS or approved equivalent inlcuding supply and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the\nEngineer-in-Charge. - 2 MODULE | BI01010001010000000000000515BI0100001113 | 6 | EA |
| 121 | 2.2 | Supply and fixing of below given white cover plate with frame for mosaic wiring accessories of M/s MDS or approved equivalent inlcuding supply and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the\nEngineer-in-Charge. - 12 MODULE ( 6 x 2) | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 122 | 2.21 | Supply and fixing of below given metal flush boxes to accommodate mosaic wiring accessories of M/s MDS or approved equivalent inlcuding supply and fixing of nuts, bolts, etc. complete with labour and materials as per\ndirection of the Engineer-in-Charge. - 1/2 MODULE | BI01010001010000000000000515BI0100001113 | 10 | EA |
| 123 | 2.22 | Supply and fixing of below given metal flush boxes to accommodate mosaic wiring accessories of M/s MDS or approved equivalent inlcuding supply and fixing of nuts, bolts, etc. complete with labour and materials as per\ndirection of the Engineer-in-Charge. - 6/8 MODULE | BI01010001010000000000000515BI0100001113 | 16 | EA |
| 124 | 2.23 | Supply and fixing of below given metal flush boxes to accommodate mosaic wiring accessories of M/s MDS or approved equivalent inlcuding supply and fixing of nuts, bolts, etc. complete with labour and materials as per\ndirection of the Engineer-in-Charge. - 12 MODULE ( 6 x 2) | BI01010001010000000000000515BI0100001113 | 4 | EA |
| 125 | 2.24 | Wiring for submain wiring with following sizes of FRLS PVC insulated, copper conductor, single core cable in recessed steel conduit as required.\nNote: Only ISI marked conduits & cables shall be used. - 2 x 4 sqmm | BI01010001010000000000000515BI0100001113 | 90 | M |
| 126 | 2.25 | Wiring for submain wiring with following sizes of FRLS PVC insulated, copper conductor, single core cable in recessed steel conduit as required.\nNote: Only ISI marked conduits & cables shall be used. - 2 x 2.5 sqmm | BI01010001010000000000000515BI0100001113 | 90 | M |
| 127 | 2.26 | Circuit wiring with 2 x 1.5 sqmm FRLS PVC insulated,copper conductor, single core cable in recessed, medium duty PVC conduit as required.\nNote: Only ISI marked conduits & cables shall be used.\n | BI01010001010000000000000515BI0100001113 | 180 | M |
| 128 | 2.27 | EARTHING WITH BARE GI WIRE EARTHING WITH BARE GI WIRE, PROVIDING AND CONNECTING EQUIPEMENT WITH EARTH BUS BAR INCLUDING SUPPLY AND FIXING OF BARE GI WIRE OF FOLLOWING SIZES AND MAKING CONNECTION WITH EQUIPMENT BY MEANS OF GI BOLTS,NUTS,WASHERS,COPPER LUGS. - 8 SWG | BI01010001010000000000000515BI0100001113 | 20 | M |
| 129 | 2.28 | PROVIDING EARTHING ELECTRODE AS PER IS 3043 STANDRAD /DRAWING/SPECIFICATION WITH FOLLOWING SIZES MEDIUM QUALITY,CLASS-B ITC/KT/JINDAL MAKE GI PIPE FABRICATED AS PER THE STANDARD DRAWING AND DRIVEN IN THE EARTH PIT FILLED UP WITH CHARCOAL OR COKE DUST MIXED WITH SALTCLAY ( 0.5 % ) INCLUDING PROVIDING INSPECTION CHAMBER - 65 MM DIA 3 M LONG | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 130 | 2.29 | SALT AND CHARCOAL FOR PIPE EARTHING EXTRA FOR USING BELOW GIVEN SALT AND CHARCOAL FOR PIPE EARTH ELECTRODE AS REQUIRED - 64 KG CHARCOAL AND 5 KG SALT | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 131 | 2.3 | COPPER LIGHT PLUG POINT WIRING IN RECESSED STEEL CONDUIT WIRING FOR LIGHT PLUG WITH 2 x 1.5 SQMM PVC INSULATED, COPPER CONDUCTOR,SINGLE CORE CABLE IN RECESSED STEEL CONDIT ALONG WITH 1 NO. 2 x 24 MM DIA BARE COPPER WIRE FOR LOOP EARTHING AS REQUIRED | BI01010001010000000000000515BI0100001113 | 3 | M |
| 132 | 2.31 | SUPPLY AND FIXING CEILING FAN SUPPLY,INSTALLATION,TESTNG AND COMMISSIONING OF CEILING FANS OF BAJAJ/CROMPTON GREAVES/KHAITAN/USHA MAKE ONLY - 1200 MM SWEEP ( WHITE ) | BI01010001010000000000000515BI0100001113 | 3 | EA |
| 133 | 2.32 | Supplying,installing,testing and commissioning of TPN tap off box of following capacity on the existing rising mains and complete with HRC fuse links,interconnections,earthingetc. as required. - 63 A TPN | BI01010001010000000000000515BI0100001113 | 2 | EA |
| 134 | 2.33 | Supply,installation,testingandcommissioningofsinglephase,FreshAirFans/HeavydutyExhaustFansofBajaj/CromptonGreaves/Khaitan/UshamakeonlyincludingsupplyandfixingwithallnecessarysupportsAllcompletewithlabourandmaterialsasperdrawings,specificationsanddirectionsofEngineer-in-Charge..NOTE:Necessarycivilworksrequiredforfixingtheexhaustfansshall be in the scope of Contractor. - HEAVY DUTY EXHAUST FAN WITH LOUVERSHUTTER 300MM SWEEP,1400 RPM | BI01010001010000000000000515BI0100001113 | 3 | each |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy