Setting Up Of Studio At J . C . Bose University Of Science And Technology , Ymca , Faridabad , Acoustic , Civil Works . , YMCA University Faridabad-Haryana

YMCA University of Science and Technology has published Setting Up Of Studio At J . C . Bose University Of Science And Technology , Ymca , Faridabad , Acoustic , Civil Works . . Submission Date for this Tender is 14-01-2021. Civil Work Tenders in YMCA University Faridabad Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

26375469
Corrigendum : Setting Up Of Studio At J . C . Bose University Of Science And Technology , Ymca , Faridabad , Acoustic , Civil Works .
National Competitive Bid
Indian
Haryana
YMCA University Faridabad
14-01-2021

Tender Details

Setting Up Of Studio At J . C . Bose University Of Science And Technology , Ymca , Faridabad , Acoustic , Civil Works .

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Jan-2021 Due to some administrative reason the tender has been extended further 2 days. Date 14-01-2021

Key Value

Document Fees
INR 5000 /-
EMD
INR 92000.0 /-
Tender Value
INR 45.82 Lakhs /-

BOQ Items

Name of Work: Setting Up of Studio at J.C. Bose University of Science & Technology, YMCA, Faridabad: Acoustic, Civil Works.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 1. Providing and fixing of Sukri / Shakti mat / Godrej brand non-metallic asbestos free composite fire cum smoke check door frame of 55mm thick shutter for 2 hrs. fire rating door system duly tested for Stability , Integrity and Insulation criteria clause 9.4 as per IS 3614 Part – 2 and BS 476 Part 22, for single and double leaf doors tested from CBRI Roorkee with Hardwood Door Frame (Red Merrantti) of section 145mm x 70mm with heat activated in tumescent fire seal strip of size 10mm x 4mm (Astroflame U.K./ Keraflix) and one coat of anti-termite fire retardant polish along with minimum 55mm thick fire / smoke check wooden shutters of 120 minute fire rating comprising of two 9mm thick Starpan / Promat calcium silicate board a 100% without asbestos, brucite and meerschaum having density not more than 950 Kg/M3 and thermal conductivity 0.14 W/m*k sandwiching 31mm thick fire resistance insulation filler coated with FR sealants and faced with 3mm thick decorative ply / 1mm laminate facing on both sides and of approved make with heat activated in tumescent fire seal strips of size 10mm x 4mm (Astroflame U.K./ keraflix) mounted in the grooves of hardwood lipping on three sides except bottom, complete factory finished. 1
2 1.01 The single/double leaf doors shall be provided with vision panels of minimum size 200 x 400 mm made out of minimum 6mm thick fire rated monolithic, clear glass of 120 min. fire rating from Schott (Germany)/Central /Firelite with complete fire rated gasket channel & moulding beading and filling the gap between moulding /beading and glass with suitable sealant including fixing each shutter with 4 Nos. stainless steel ball bearing hinges 304 grade of size 102mm x 76mm x 3mm with screws. The manufacturer should have tested the entire assembly from CBRI Roorkee along with the required size of fire rated vision panels and approved hardware for 2 hrs. fire rating and shall submit the same for both single leaf and double leaf configurations prior to manufacturing, to the Engineer-in-charge for approval of the agency. One door shall out of the entire lot shall be tested from CBRI Roorkee and the testing charges shall be reimbursed to the contractor on successful submission of the test reports. 2
3 1.02 The single/double leaf doors shall be provided with vision panels of minimum size 200 x 400 mm made out of minimum 6mm thick fire rated monolithic, clear glass of 120 min. fire rating from Schott (Germany)/Central /Firelite with complete fire rated gasket channel & moulding beading and filling the gap between moulding /beading and glass with suitable sealant including fixing each shutter with 4 Nos. stainless steel ball bearing hinges 304 grade of size 102mm x 76mm x 3mm with screws. The manufacturer should have tested the entire assembly from CBRI Roorkee along with the required size of fire rated vision panels and approved hardware for 2 hrs. fire rating and shall submit the same for both single leaf and double leaf configurations prior to manufacturing, to the Engineer-in-charge for approval of the agency. One door shall out of the entire lot shall be tested from CBRI Roorkee and the testing charges shall be reimbursed to the contractor on successful submission of the test reports Make: Sukri / Shakti mat / Godrej complete in all respect with the prior approval of Engineering In Charge. 3 50 Sq.mt.
4 2 Supply and fixing of 2 hrs. fire rated CBRI tested as per IS 3614 Part -2 and BS 476 Part-22 stainless steel 304 grade fire rated ball bearing hinges of size 102mm x 76mm x 3mm thick \nMake: I.R / Dorma BB 4330/ Marshall complete in all respect with the prior approval of Engineering In Charge. 4 78 Each
5 3 Supply and fixing of 2 hrs. fire rated CBRI tested as per IS 3614 Part -2 and BS 476 Part-22 door closers having rack and pinion mechanism, with standard arm, dual speed control, CE certifier, having 1 year’s mechanical warranty Make: I.R LCN 1461 / Dorma TS 73 / Marshall MH DC- S- 14003 complete in all respect with the prior approval of Engineering In Charge tested from CBRI Roorkee along with the fire door assembly. 5 13 Each
6 4 Supply and fixing of 2hrs. fire rated CBRI tested as per IS 3614 Part -2 and BS 476 Part-22 mortise dead lock with 80mm cylinder having one side key and one side thumb turn operation Make: I.R Briton EL 2020 series / Dorma 288 series / MHLDL 13002 complete in all respect with the prior approval of Engineering In Charge. 6 13 Each
7 5 Supply and fixing of 2 hrs. fire rated CBRI tested as per IS 3614 Part -2 and BS 476 Part-22 stainless steel D-Type pull handle of size 22mm dia and 300mm long Make: Dorma TGDI series / IR -Briton / Marshall complete in all respect with the prior approval of Engineering In Charge. 7 16 Each
8 6 Anutone Subtex Ebony, 595x595x15mm, Square edge, T24 grid system. 8
9 6.01 Supply and Installation of Anutone Subtex Ebony, square edge, Glassfibre core fully encapsulated ceiling tile of size 595x595x15mm having volume density 120Kgs/m3, suspended using 0.3mm thick Anutone Skelet Trelis T24 ebony metal grid system. 9
10 6.02 Anutone Skelet Trelis T24 ceiling grid system, in Ebony, of 600x600mm module includes Anutone Skelet WA24B30 with equal flanges of 24mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centres.\nThen suspend the Anutone Skelet MT24B36 with flange width 24mm, height 38mm and length 3600mm, from the soffit slab with help of Anchor Bolt, Soffit Cleat and Suspension Rod with Levelling Clip at 1200mm centres.\nAnutone Skelet CT24B12 with flange width 24mm, height 32mm and length 1200mm is interlocked into the pre-cut slots in the Main T24 at 600mm centres in the perpendicular direction to the Main T24.\nFinally Anutone Skelet CT24B06 with flange width 24mm, height 32mm and length 600mm are interlocked into the precut slots in the CT24B12 in direction parallel to the Main T24 to result in 600x600mm module.\nAnutone Subtex Ebony of size 595x595x15mm shall be placed into the grid size of 600x600mm.\nEnsure arrow marks behind the tiles are oriented in one direction to achieve uniform shade. \nMake: Anutone, Armstrong, Idea Acoustics complete in all respect with the prior approval of Engineering In Charge. 10 385 Sqm
11 7 Anutone Subtex Nubby, 595x595x15mm, Square edge, T24 grid system 11
12 7.01 Supply and Installation of Anutone Subtex Nubby, square edge, Glassfibre core fully encapsulated ceiling tile of size 595x595x15mm having volume density 120Kgs/m3, suspended using 0.3mm thick Anutone Skelet Trelis T24 ebony metal grid system. 12
13 7.02 Anutone Skelet Trelis T24 ceiling grid system, in white, of 600x600mm module includes Anutone Skelet WA24W30 with equal flanges of 24mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centres.\nThen suspend the Anutone Skelet MT24W36 with flange width 24mm, height 38mm and length 3600mm, from the soffit slab with help of Anchor Bolt, Soffit Cleat and Suspension Rod with Levelling Clip at 1200mm centres.\nAnutone Skelet CT24W12 with flange width 24mm, height 32mm and length 1200mm is interlocked into the pre-cut slots in the Main T24 at 600mm centres in the perpendicular direction to the Main T24.\nFinally Anutone Skelet CT24W06 with flange width 24mm, height 32mm and length 600mm are interlocked into the precut slots in the CT24W12 in direction parallel to the Main T24 to result in 600x600mm module.\nAnutone Subtex Nubby of size 595x595x15mm shall be placed into the grid size of 600x600mm.\nEnsure arrow marks behind the tiles are oriented in one direction to achieve uniform shade. \n`Make: Anutone, Reliance, Owens Coming complete in all respect with the prior approval of Engineering In Charge. 13 160 Sqm
14 8 Lower reaches:-Anutone Slats Surco 128 x2440x16mm, T&G edge (From skirting top level upto 1.2m) 14
15 8.01 Supply & installation of Anutone Salon Slats Surco made of pinewood E1 grade fiberboard, melamine laminated finish, groove perforated slats L8-2 - (2mm grooves @ 8mm centers) / L16-2 - (2mm Slats @16mm pitch) / L32-2 - (2mm grooves @ 32mm centers) / L64-2 - (2mm grooves @ 64mm centers), backlined with Soundtexblack acoustical fleece of 0.27mm thick, surface density 63g/m2,tongue-groove edge for a seamless look, 5-test fire retardant grade, size 128 x2440x16mm, volume density of base board 700Kg/m3, weight 9Kg/m2 (L16), 10.5Kg/m2 (L32), 11Kg/m2 (L64) installed by using Anutone Strut framework system. 15
16 8.02 The Anutone Strut framework system shall include Anutone Strut CC25, fully knurled, sectional thickness 0.55mm, length 3600mm, web 50mm, depth of 25mm and equal flanges 15mm is fastened to the wall positioned horizontally/vertically at every 600mm centres.\nAnutone Strut CC18,aluminium core cross channel, thickness 0.5mm, length 2400mm, web 15mm & 27mm, depth 18mm and flanges of 7mm with suitable edge & center brackets is then fixed perpendicular to the Strut CC25 with the help of fasteners at every 400mm centers\nAnutone Slats Surco of size 128x 2440x16mm in then fixed perpendicular to Strut CC18 with suitable edge & centre brackets. Contractor to provide expansion joints of 3mm at every 4.88m length wise and 4.992m width wise. \nNote:-Wooden packing of appropriate thickness to be provided at rear of strut to bring finish inline with Strand 1Color finish. 16
17 8.03 The system is backlined with Anutone SynthPF 10x25 adhered on wall with stick S7. Make: Armstrng, Anutone, Idea Acoustics complete in all respect with the prior approval of Engineering In Charge. 17 240 Sqm
18 9 Upper reaches:-Anutone Pixel Smery, 1200x2400x12.5mm, Taper Edge 18
19 9.01 Supply and Installation of Anutone Pixel Smery, perforated GFR gypsum panels, consisting of Anutone Pixel 0308 panel, backlined with acoustical fleece, having 3x3mm square perforations @ 8.33mm pitch - 8 % open area, size 1200x2400x12.5mm tapered long edges, volume density of base board 700 Kgs/m3, weight 9Kgs/m2 finished with Anutone Smery acoustical paper, size 1000x25000x0.75mm and acrylic paint (Paint not by Anutone) installed by using Anutone Strut framework system. 19
20 9.02 The Anutone Strut framework systems includes Anutone Strut CC25, fully knurled, sectional thickness 0.55mm, length 3600mm, web 50mm, depth of 25mm and equal flanges 15mm is fastened to the wall positioned horizontally at 600mm centers for upto RH70, at 400mm centers for RH70-RH90 and at 300mm centers for >RH90. \nAnutone Pixel 0308 is installed on the Strut CC25 with suitable fasteners at 600/400/300mm centres.\nThe longer edges of panels should be perpendicular to length of Strut CC25.\nThe tapered longer edges are then filled and finished with Anutone Seam AJC and tape (tape not by Anutone).\nThe short square edges are also similarly finished but no tape. Apply one coat of white primer (Paint not by Anutone) with roller brush evenly across the Pixel surface to achieve uniform colour. Note:-Wooden packing of appropriate thickness to be provided at rear of strut to bring finish inline with Slats Surco finish. 20
21 9.03 Smery Paper Installation:\nApply vinyl glue thinly, evenly and fully on Anutone Pixel to receive the Anutone Smery acoustical paper. \nCut Smery rolls with sharp knife to required size. \nPaste the Smery on Pixel and smooth it with plastic rasper.\nEnsure butt joints between successive drops are fine and level. Wherever Smery joints are aligned with Pixel perforations ensure to block/close the perforations by using Seam AJC to achieve smooth surface below the joints. \nSmery is finished with approved colour water base acrylic paint by using roller brush. \nPaint a second finishing coat on the Smery when the first coat is dry.(Paint not by Anutone) 21
22 9.04 The system is backlined with the acoustical infill Anutone SynthPF 10x25 adhered using Stick S7. Make: anutone, AMF, Denoline complete in all respect with the prior approval of Engineering In Charge. 22 212 Sqm