Lucknow Development Authority has published Tender For Installation Of Synchronizing Panel For Generator And Supply Of Generator Backup Electric Work -Jankipuram Yojna Sector J Kursi Raod Sthith Srasti Apartment Me Purwa Se Sthapit Generatro Hetu Synronizing Panel Lagane And Apartment Ke Avantiyo K. Submission Date for this Tender is 30-12-2020. Electrification Work Tenders in GOMTI NAGAR LUCKNOW Uttar Pradesh. Bidders can get complete Tender details and download the document.
Name of Work: tkudhiqje~ ;kstuk lsDVj ts dqlhZ jksM fLFkr l`f"V vikVZesaV esa iwoZ esa LFkkfir tujsVjks gsrq flUdzksukbZftax iSuy yxkus rFkk vikVZesaV ds vkoafV;ks dks tujsVj dh cSdvi fo|qr vkiwfrZ miyC/k djkus dk dk;ZA | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. | |||
2 | 2 | 25 sq. mm 3-1/2 core | 200 | Mtr | |
3 | 3 | 35 sq. mm 3-1/2 core | 200 | Mtr | |
4 | 4 | 50 sq. mm 3-1/2 core | 200 | Mtr | |
5 | 5 | 120 sq. mm 3-1/2 core | 440 | Mtr | |
6 | 6 | 150 sq. mm 3-1/2 core | 300 | Mtr | |
7 | 7 | 240 sq. mm 3-1/2 core | 150 | Mtr | |
8 | 8 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. | |||
9 | 9 | 240 sq. mm 3-1/2 core | 2 | Nos | |
10 | 10 | 185 sq. mm 3-1/2 core | 2 | Nos | |
11 | 11 | 120 sq. mm 3-1/2 core | 8 | Nos | |
12 | 12 | 50 sq. mm 3-1/2 core | 16 | Nos | |
13 | 13 | 35 sq. mm 3-1/2 core | 16 | Nos | |
14 | 14 | 25 sq. mm 3-1/2 core | 16 | Nos | |
15 | 15 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. | |||
16 | 16 | 240 sq. mm | 8 | Nos | |
17 | 17 | 185 sq. mm | 8 | Nos | |
18 | 18 | 120 sq. mm | 32 | Nos | |
19 | 19 | 50 sq. mm | 64 | Nos | |
20 | 20 | 35 sq. mm | 64 | Nos | |
21 | 21 | 25 sq. mm | 64 | Nos | |
22 | 22 | S/F of thermoplastic cable junction box IP 66/IP 67 wheather proof for out door installation with knockouts for cable entry suitable for 16-50 mm size cable size of box 255x355x122 mm with out terminas all complete hensal/syntex or equivelent make all as per direction of E/Ic(Analysis Rate) | 104 | Nos | |
23 | 23 | Supply and wiring of submain with three number 2.5 sq.mm. PVC insulated 1100 V grade single core aluminium conductor cable in 20 mm dia. heavy guage cable in 20 mm dia. heavy duty(2mm thick) PVC conduit with one number 1.5 sqmm FRLSH PVC inslulated 1100 V Grade multistand copper conductor cable as earth continuity wire drawn in inside the conduit etc.,complete in all respect. | 15600 | Nos | |
24 | 24 | S/F of SPN 30 amp main 3amp DG automatic changeover with current limiter (ACCL) switch with intelligent micro controller based design havels/indo/asian/L&T make all complete as per direction of E/Ic. (analysis Rate) | 520 | Nos | |
25 | 25 | Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of two no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respect. | 6 | Nos | |
26 | 26 | Supply and fixing of vertical down conductor of 32mm x 6mm G.I. strip etc. on approved clamps on surface for lightning conductor complete in all respects (for two storeyed Buildings). | 300 | Mtr | |
27 | 27 | Desining manufacuring supply installation testing & commissoning of emergency main pannel wit DG synchronization of 250, 160 & 125 KVA complete with al material mantion as under as per direction of E/ic | 1 | job | |
28 | 28 | Incomer From Main LT Panel | |||
29 | 29 | 200A TP MCCB 25 KA WITH O/L & S/C THERMAL MAGNETIC RELEASE-03 nos | |||
30 | 30 | SPREADER LINK-3nos | |||
31 | 31 | ROTARY OPERATING MECHANISM-3nos | |||
32 | 32 | 200A FP CONTACTOR AC-1 DUTY-03nos | |||
33 | 33 | MULTIFUNCTION METER WITH RS485 PORT-03 | |||
34 | 34 | CT 200/5A-09 | |||
35 | 35 | PHASE INDICATING LAMP-09 | |||
36 | 36 | ON/OFF INDICATING LAMP-09 | |||
37 | 37 | CONTROL MCB-12 | |||
38 | 38 | NEUTRAL LINK-03 | |||
39 | 39 | Incomer from 250kva DG set | |||
40 | 40 | 400A TP MCCB 36 KA WITH O/L & S/C THERMAL MAGNETIC RELEASE-01 | |||
41 | 41 | SPREADER LINK-01 | |||
42 | 42 | ROTARY OPERATING MECHANISM-01 | |||
43 | 43 | 400A FP CONTACTOR AC-1 DUTY-01 | |||
44 | 44 | MULTIFUNCTION METER WITH RS485 PORT-01 | |||
45 | 45 | CT 400/5A-03 | |||
46 | 46 | PHASE INDICATING LAMP-03 | |||
47 | 47 | ON/OFF INDICATING LAMP-02 | |||
48 | 48 | CONTROL MCB-04 | |||
49 | 49 | NEUTRAL LINK-01 | |||
50 | 50 | Incomer from 160kva DG set | |||
51 | 51 | 250A TP MCCB 25 KA WITH O/L & S/C THERMAL MAGNETIC RELEASE-01 | |||
52 | 52 | SPREADER LINK-01 | |||
53 | 53 | ROTARY OPERATING MECHANISM-01nos | |||
54 | 54 | 250A FP CONTACTOR AC-1 DUTY-01nos | |||
55 | 55 | MULTIFUNCTION METER WITH RS485 PORT-01nos | |||
56 | 56 | CT 250/5A-03nos | |||
57 | 57 | PHASE INDICATING LAMP-03nos | |||
58 | 58 | ON/OFF INDICATING LAMP-02nos | |||
59 | 59 | CONTROL MCB-02nos | |||
60 | 60 | NEUTRAL LINK-01nos | |||
61 | 61 | Incomer from 125kva DG set | |||
62 | 62 | 200A TP MCCB 25 KA WITH O/L & S/C THERMAL MAGNETIC RELEASE-01nos | |||
63 | 63 | SPREADER LINK-01nos | |||
64 | 64 | ROTARY OPERATING MECHANISM-01nos | |||
65 | 65 | 200A FP CONTACTOR AC-1 DUTY-01nos | |||
66 | 66 | MULTIFUNCTION METER WITH RS485 PORT-01nos | |||
67 | 67 | CT 200/5A-03nos | |||
68 | 68 | PHASE INDICATING LAMP-03nos | |||
69 | 69 | ON/OFF INDICATING LAMP-02nos | |||
70 | 70 | CONTROL MCB-04nos | |||
71 | 71 | NEUTRAL LINK-01nos | |||
72 | 72 | Bus Coupler-01 | |||
73 | 73 | 250A FP CONTACTOR AC-1 DUTY-01nos | |||
74 | 74 | ON/OFF INDICATING LAMP-02nos | |||
75 | 75 | CONTROL MCB-01nos | |||
76 | 76 | NEUTRAL LINK-01nos | |||
77 | 77 | Bus Coupler-02 | |||
78 | 78 | 200A FP CONTACTOR AC-1 DUTY-01nos | |||
79 | 79 | ON/OFF INDICATING LAMP-02nos | |||
80 | 80 | CONTROL MCB-01nos | |||
81 | 81 | NEUTRAL LINK-01nos | |||
82 | 82 | Interlocking | |||
83 | 83 | ELECTRICAL INTERLOCKING BETWEEN INCOMER CONTACTORS & BUS COUPLER CONTACTORS-01nos | |||
84 | 84 | Auto Load Management system | |||
85 | 85 | PROGRAMMABLE LOGIC CONTROL CONSISTING OF PLC WITH 32 CHANNEL DIGITAL INPUT & 32 CHANNEL DIGITAL OUTPUT MODULE AND 8 CHANNEL ANALOG INPUT, VOLTAGE SELECTOR SWITCH, MOTORISED POTENTIOMETER, 12 WINDOW ANNUNCIATOR, 24 WINDOW MICRO FACIA, MICROPROCESSOR BASED COMPUTER, SWITCHING MODE POWER SUPPLY ETC.-01 nos | |||
86 | 86 | BATTERY CHARGER | |||
87 | 87 | BATTERY CHARGER FOR DG SETS WITH INBUILT TRICKLE & BOOST FACILITY, DC AMMETER, DC VOLTMETER, SELECTOR SWITCH, INDICATING LAMP ETC.-03nos | |||
88 | 88 | Outgoing on Bus section-01 | |||
89 | 89 | 100A TP MCCB 25 KA WITH O/L & S/C THERMAL MAGNETIC RELEASE-07nos | |||
90 | 90 | SPREADER LINK-07nos | |||
91 | 91 | ROTARY OPERATING MECHANISM-07nos | |||
92 | 92 | Outgoing on Bus section-02 | |||
93 | 93 | 100A TP MCCB 25 KA WITH O/L & S/C THERMAL MAGNETIC RELEASE-07nos | |||
94 | 94 | SPREADER LINK-07nos | |||
95 | 95 | ROTARY OPERATING MECHANISM-07nos | |||
96 | 96 | Outgoing on Bus section-03 | |||
97 | 97 | 100A TP MCCB 25 KA WITH O/L & S/C THERMAL MAGNETIC RELEASE-04nos | |||
98 | 98 | SPREADER LINK-04nos | |||
99 | 99 | ROTARY OPERATING MECHANISM-04nos | |||
100 | 100 | Accessories | |||
101 | 101 | CO-AXIAL PANEL FAN-06nos | |||
102 | 102 | AIR FILTER-06nos | |||
103 | 103 | SPACE HEATER WITH THERMOSTAT-04nos | |||
104 | 104 | PANEL LIGHT WITH DOOR LIMIT SWITCH-04nos | |||
105 | 105 | FABRICATION OF PANEL INDOOR TYPE COMPARTMENTALISED DESIGN FABRICATED OUT OF 14/16 GAUGE THICK COLD ANNAMELED COLD ROLLED SHEET STEEL WITH LOCKABLE DOORS AT FRONT & BACK & TOP/BOTTOM GLAND PLATE | |||
106 | 106 | ALLUMINIUM BUSBAR OF ELECTROLYTIC GRADE ALLUMINIUM OF SIZE 40X10 FOR PHASE & 40X6 FOR NEUTRAL | |||
107 | 107 | POWER WIRING WITH REQUIRED RATING OF COPPER FLEXIBLE WIRE | |||
108 | 108 | CONTROL WIRING WITH 1.5 SQ. MM. COPPER FLEXIBLE WIRE | |||
109 | 109 | PANEL ACCESSORIES I.E. BUSBAR SLEEVES, BUSBAR SUPPORTS, WIRE SLEEVES, THIMBLES, FERRULES, TERMINAL BLOCK, NECESSARY HARDWARES, BACKELITE SHEET, ACRYLIC SHEET ETC. | |||
110 | 110 | Modification in existing 125KVA & 160 KVA DG sets (Make CHS) for synchronization compatibility system including providing voltage regulars in DG sets current transformers in DG sets complete with reuqired material labour T&P etc all respects as per direction of E/Ic | 2 | Nos | |
111 | 111 | Deduct in item no-501(I) 501(T) and 506(a) to (f) when cables is passed through G.I./M.S. or hume pipe in road crossing or along the wall the cost of the G.I. Pipe hume pipe is to be extra when and where required | 1490 | Mtr |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy