State Plan 20 21 Arwss To Veliyanoor And Adjoining Villages Supply Erection And Commissioning Of 75Hp Centrifugal Pump Set For Muthukulammala Boosting Station And Allied Works
Tender Value
12.80 Lakhs
Estimated cost
Bid Submission
30 Dec 2020
0 days left
EMD
32010
Bank guarantee accepted
Document Fee
2560
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Uzhavoor → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
State Plan 20 21 Arwss To Veliyanoor And Adjoining Villages Supply Erection And Commissioning Of 75Hp Centrifugal Pump Set For Muthukulammala Boosting Station And Allied Works
BOQ
| Work Name:STATE PLAN -2020-21- ARWSS TO VELIYANNOOR AND ADJOINING VILLAGES SUPPLY ERECTION TESTING AND COMMISSIONING OF 75HP CENTRIFUGAL PUMP SET FOR MUTHUKULAM MALA BOOSTING STATION AND ALLIED WORKS | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | STATE PLAN ARWSS TO VELIYANNOOR AND ADJOINING VILLAGES SUPPLY ERECTION TESTING AND COMMISSIONING OF 75HP CENTRIFUGAL PUMP SET FOR MUTHUKULAM MALA BOOSTING STATION AND ALLIED CABLING WORKS | BI01010001010000000000000515BI0100001112 | ||
| 2 | 1.001 | Supply and erection of >75 hp CF pump set total head up to 112M Supply and erection of CF pump set with the following specification <br>1. Pump Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete The duty condition is as follows <br>Discharge - 40 LPS <br>Total head - 112mtrs <br>Suction head - 7 mtrs<br>Length of suction pipe - 7 mtrs <br>Alternatively the inlet & out let levels, type, size& length of pumping main etc. can be given. Modification may done for monoblock pump sets <br>2. Motor Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V (select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors. <br>3. Starter Supply, erection, testing and commissioning of suitable rating (Fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters to be used.) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete. <br>4. Panel board (suitable for operating two pump sets but one pump set at a time) Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified if there is only one pump set by changing 2 Nos of out going as one out going and the provision of interlocking may be avoided) <br>5. Cabling work Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation. <br>6. Earthing Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. <br>7. Capacitor Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834 <br>8. Valves Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. <br>9. Suction and delivery pipe connections Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80 mm CI pipes & specials shall be provided. <br>( | BI01010001010000000000000515BI0100001113 | 1 | L.S |
AI Tender Summary
Tender Timeline
Dec 23, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedDec 30, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 04, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender