| 1 | 1 | Drilling of 609.60 mm dia bore by Rerverse rotary drilling (Reverse Circulation method) according to ISI specification No.2800-1991 (Part-1) as amended upto date and modified to extent of the specification attached with this schedule of items of work in all kinds of soils and boulders upto 125mm dia except rocky strata including the cost of all consumable stores, fuel oils, soil, stabilizing material and transportation of rig and other accessories to the site of proposed bore and back, complete to the satisfaction of the Engineer-in-Charge with Contractor Pvt. Rig.Machine. | BI01010001010000000000000515BI0100001113 | 150 | mtrs |
|---|
| 2 | 2 | Providing fixing of 200mm i/d 6.4 mm thick plain ended Electric Resistance Welded (ERW) M.S. Pipes as per IS marked 4270:2001 BIS 2001 (Length of pipe 4 to 7 mtr.) | BI01010001010000000000000515BI0100001114 | 130 | mtrs |
|---|
| 3 | 3 | Providing Fixing for lowering 200mm i/d all welded S.S.screen conforming to ISI 8110-2000, and thickness 8mm, slot opening 0.75mm/0.50mm | BI01010001010000000000000515BI0100001115 | 20 | mtrs |
|---|
| 4 | 4 | Providing & fixing of M.S. bail plug end cap. | BI01010001010000000000000515BI0100001113 | 1 | Each |
|---|
| 5 | 5 | Providing & fixing of Center Guides. (i) 200mm ø (1x 3 = 3 Nos.) | BI01010001010000000000000515BI0100001115 | 3 | Each |
|---|
| 6 | 6 | Providing & fixing of M.S. cap 200mm ø. | BI01010001010000000000000515BI0100001113 | 1 | Each |
|---|
| 7 | 7 | Supplying & packing of Pea Gravel (A-Grade) for use as pack in tubewells size of over 2.00mm to 3.35mm with uniformity coefficient Not to exceed 2.00. The Gravel should be confirming To requirement of ISI, 4097-1967 regarding its physical Characteristic quarry at Panchkula/Chandi Mandir. 40 cum | BI01010001010000000000000515BI0100001114 | 40 | cum |
|---|
| 8 | 8 | Provision for resistivity servy of the area | BI01010001010000000000000515BI0100001113 | 1 | job |
|---|
| 9 | 9 | Water arrangement for drilling work. | BI01010001010000000000000515BI0100001113 | 1 | job |
|---|
| 10 | 10 | Pit preparation complete work.With filling of pits after drilling of T/Well | BI01010001010000000000000515BI0100001114 | 1 | job |
|---|
| 11 | 11 | Providing & Fixing 8\" MS Clamp for supporting 219.10 mm housing pipe with sutable giders complete in all respect. | BI01010001010000000000000515BI0100001115 | 1 | Each |
|---|
| 12 | 12 | Development of tubewell with Air Compressor having capacity 250PSI 450 CFM according to clause 9.3 of IS: 2800 - 1991 (Part-I) as amended upto date and specifications attached and as directed by the Engineer-in-Charge of the work including the cost of all consumable stores, fuel, oil, compressors and machinery etc. as required for this work. Developed by Air Compressor of 250 PSI 450 CFM. (1 x 10 = 10 Hrs.) | BI01010001010000000000000515BI0100001113 | 10 | hrs |
|---|
| 13 | 13 | Providing and testing Electric logging of Tubewell | BI01010001010000000000000515BI0100001113 | 1 | job |
|---|
| 14 | 14 | Supplying, erection testing and commissioning of submersible pumping sets as per BIS SPECIFICATION No. 8034 - 1989 (as amended up to date for pumps ) and IS 9283 – 1979 (as amended up to date for motor ) the pump motor sets should be capable of pumping clear fresh cold water having characteristics as specified in Clause – 4 of IS 8034 – 1989 and clause 4.1 of IS 9283 – 1979 .250 LPM /90 M Head 10.00 BHP Each Make , KSB , Texmo, CRI, Kirloskar | BI01010001010000000000000515BI0100001113 | 1 | Each |
|---|
| 15 | 15 | Supplying erection, testing of fully automatic Electric Control Panel Board for tubewells in pump chamber consisting of MS sheet of thickness 14 gauge duly painted box type floor mounted made of Angle Frame containing 1 No. fully automatic air brake starter suitable for 25 HP motor, Main switch of suitable range with HRC fuse, 1 No. Volt Meter (0 to 500 Volts), 1 No. Amp. Meter of 0 to 100 Amp. 3 Sets of indicating lamp Capacitor of suitable capacity and 1 No. single phase preventers with the timers switch including wiring in panel board and suitable electric energy meter wiring in Electric Control Panel Board complete in all respect as per specification given in Schedule No.II. (Make L&T, BCH, , Havells). | BI01010001010000000000000515BI0100001114 | 1 | Each |
|---|
| 16 | 16 | Prov. and fixng M.S. Clamp | BI01010001010000000000000515BI0100001114 | 1 | Each |
|---|
| 17 | 17 | Providing & Fixing 2\" C.I Bend (2\"x90°) of heavy duty. One side 2\" flange & one side 3\" flange with nut bolt and Rubber seat complete in all respect | BI01010001010000000000000515BI0100001114 | 25 | kg |
|---|
| 18 | 18 | Providing, and fixing D plate of size 300mm. with nut & bolt complete. | BI01010001010000000000000515BI0100001114 | 1 | Each |
|---|
| 19 | 19 | Providing, and fixing 2\" G.I Pipe 2\"B Class (Deliver Pipe) | BI01010001010000000000000515BI0100001114 | 5 | mtrs |
|---|
| 20 | 20 | Providing and fixing service cable 25 sqmm 4 core aluminum | BI01010001010000000000000515BI0100001114 | 25 | mtrs |
|---|