Re-Tender Of Construction Of 2Nd And 3Rd Floor Above Central Library Of Sctce Trivandum Re-Tender Of Construction Of 2Nd And 3Rd Floor Above Central Library Of Sree Chitra Thirunal College Of Engineering Trivandum
Tender Value
1.37 Crore
Estimated cost
Bid Submission
30 Dec 2020
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
TRIVANDRUM → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Re-Tender Of Construction Of 2Nd And 3Rd Floor Above Central Library Of Sctce Trivandum Re-Tender Of Construction Of 2Nd And 3Rd Floor Above Central Library Of Sree Chitra Thirunal College Of Engineering Trivandum
BOQ
| Name of Work: Construction of 2nd & 3rd floor above the central library of Sree Chitra Thirunal College of Engineering, Thiruvananthapuram | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar | 1 | 15.88 | cum |
| 2 | 2 | Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. | 2 | 9.01 | cum |
| 3 | 3 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | 3 | 22.083 | cum |
| 4 | 4 | Chemical anchoring ,application includes drilling at specified depth, cleaning, injecting the chemical and fixing the rebar on concrete.<br>16mm rebar at 260mm depth | 4 | 100 | holes |
| 5 | 5 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level | 5 | 97.022 | cum |
| 6 | 6 | Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers | 6 | 353.193 | sqm |
| 7 | 7 | Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts | 7 | 195.024 | sqm |
| 8 | 8 | Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | 8 | 347.942 | sqm |
| 9 | 9 | Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges | 9 | 50.514 | sqm |
| 10 | 10 | Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide | 10 | 61.75 | m |
| 11 | 11 | Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) | 11 | 346.502 | sqm |
| 12 | 12 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 12 | 14519.9 | kg |
| 13 | 13 | Modified 6.26.2<br>Brick work with common burnt clay selected F.P.S (non modular ) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 ( 1 cement : 6 coarse sand)<br>Above plinth level and upto floor V level(from floor 2 level up to floor 5 level) | 13 | 60.96 | cum |
| 14 | 14 | Solid block masonry using pre cast solid blocks( Factory made) of size 40x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete | 14 | 20.76 | cum |
| 15 | 15 | Modified 50.6.3.2 <br>Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto five level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete | 15 | 2.75 | cum |
| 16 | 16 | Applying two coat of clear coat on Exposed brick surface and including all cost and conveyance of all materials and labour charges etc. complete. | 16 | 207.2 | sqm |
| 17 | 17 | Pointing on brick work or brick flooring with cement mortar 1:3 ( 1 cement : 3 fine sand):Raised and cut pointing | 17 | 207.2 | sqm |
| 18 | 18 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | 18 | 554.002 | sqm |
| 19 | 19 | 9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete | 19 | 383.677 | sqm |
| 20 | 20 | Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. | 20 | 328 | m |
| 21 | 21 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood | 21 | 0.198 | cum |
| 22 | 22 | Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge.using Anjili/ Jack wood | 22 | 13.05 | sqm |
| 23 | 23 | Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood | 23 | 9.001 | sqm |
| 24 | 24 | Providing and fixing bright finished stainless steel 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | 24 | 4 | no |
| 25 | 25 | OD 9.66.1<br>Providing and fixing ISI marked S.S. handles conforming to IS : 4992 with necessary screws etc. complete:<br>300 mm\"<br> | 25 | 16 | no |
| 26 | 26 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) | 26 | 16 | each |
| 27 | 27 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete:125x64x1.90 mm | 27 | 32 | no |
| 28 | 28 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm | 28 | 16 | no |
| 29 | 29 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron ) | 29 | 153.882 | kg |
| 30 | 30 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micorn) | 30 | 199.584 | kg |
| 31 | 31 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness | 31 | 41.22 | sqm |
| 32 | 32 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. | 32 | 12.2 | m |
| 33 | 33 | Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge. | 33 | 3.6 | sqm |
| 34 | 34 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding | 34 | 659.52 | kg |
| 35 | 35 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. | 35 | 341.046 | sqm |
| 36 | 36 | Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm | 36 | 13.761 | sqm |
| 37 | 37 | Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) | 37 | 0.723 | cum |
| 38 | 38 | Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm | 38 | 1.44 | sqm |
| 39 | 39 | Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work | 39 | 2.4 | m |
| 40 | 40 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. | 40 | 17.06 | sqm |
| 41 | 41 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done | 41 | 872.8 | sqm |
| 42 | 42 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer | 42 | 937.69 | sqm |
| 43 | 43 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete | 43 | 937.69 | sqm |
| 44 | 44 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work | 44 | 937.69 | sqm |
| 45 | 45 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture | 45 | 79.83 | sqm |
| 46 | 46 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level | 46 | 47.806 | cum |
| 47 | 47 | Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers | 47 | 183.383 | sqm |
| 48 | 48 | Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts | 48 | 142.784 | sqm |
| 49 | 49 | Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | 49 | 114.22 | sqm |
| 50 | 50 | Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges | 50 | 50.514 | sqm |
| 51 | 51 | Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide | 51 | 136.78 | m |
| 52 | 52 | Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) | 52 | 112.78 | sqm |
| 53 | 53 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 53 | 7478.05 | kg |
| 54 | 54 | Modified 6.26.2<br>Brick work with common burnt clay selected F.P.S (non modular ) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 ( 1 cement : 6 coarse sand)<br>Above plinth level and upto floor V level(from floor 2 level up to floor 5 level) | 54 | 82.716 | cum |
| 55 | 55 | Solid block masonry using pre cast solid blocks( Factory made) of size 40x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in: CM 1:6 ( 1 cement : 6 thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete | 55 | 25.16 | cum |
| 56 | 56 | Modified 50.6.3.2 <br>Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto five level for 10 cm thick wall in : CM upto five level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete | 56 | 3.09 | cum |
| 57 | 57 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes | 57 | 11174.6 | kg |
| 58 | 58 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | 58 | 519.75 | sqm |
| 59 | 59 | Roofing with Aluminium plain sheets 0.80mm thick with overlap of 150mm at ends and G.I. hooks or crank bolts and nuts including plain washers and bitumen washers, cost and conveyance of all materials,labour charges etc complete | 59 | 519.75 | sqm |
| 60 | 60 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm) | 60 | 125.8 | m |
| 61 | 61 | Providing and fixing 150mm PVC half split eve gutter including all cost and conveyance of all materials and labour charges<br> | 61 | 54.55 | m |
| 62 | 62 | Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 15 mm dia 10Kgf/cm2 | 62 | 68 | m |
| 63 | 63 | Applying two coat of clear coat on Exposed brick surface and including all cost and conveyance of all materials and labour charges etc. complete. | 63 | 283.327 | sqm |
| 64 | 64 | Pointing on brick work or brick flooring with cement mortar 1:3 ( 1 cement : 3 fine sand):Raised and cut pointing | 64 | 283.327 | sqm |
| 65 | 65 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | 65 | 773.751 | sqm |
| 66 | 66 | 9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete | 66 | 153.341 | sqm |
| 67 | 67 | Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. | 67 | 101.6 | m |
| 68 | 68 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), dash fastener shall be paid for separately), using good quality Anjili wood /jack wood | 68 | 0.276 | cum |
| 69 | 69 | Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge.using Anjili/ Jack wood | 69 | 14.138 | sqm |
| 70 | 70 | Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood | 70 | 8.813 | sqm |
| 71 | 71 | Providing and fixing bright finished stainless steel 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.<br> | 71 | 6 | no |
| 72 | 72 | OD 9.66.1<br>Providing and fixing ISI marked S.S. handles conforming to IS : 4992 with necessary screws etc. complete:<br>300 mm\"<br> | 72 | 24 | no |
| 73 | 73 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) | 73 | 24 | each |
| 74 | 74 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete:125x64x1.90 mm | 74 | 48 | no |
| 75 | 75 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm | 75 | 24 | no |
| 76 | 76 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steelscrews, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron ) | 76 | 153.882 | kg |
| 77 | 77 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micorn) | 77 | 199.584 | kg |
| 78 | 78 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness | 78 | 41.22 | sqm |
| 79 | 79 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. | 79 | 12.2 | m |
| 80 | 80 | Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge. | 80 | 3.6 | sqm |
| 81 | 81 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding | 81 | 659.52 | kg |
| 82 | 82 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. | 82 | 339.251 | sqm |
| 83 | 83 | Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm | 83 | 13.618 | sqm |
| 84 | 84 | Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) | 84 | 0.723 | cum |
| 85 | 85 | Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm | 85 | 1.44 | sqm |
| 86 | 86 | Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work | 86 | 2.4 | m |
| 87 | 87 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry | 87 | 16.08 | sqm |
| 88 | 88 | Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron) consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-Charge ( level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately ). | 88 | 519.75 | kg |
| 89 | 89 | Providing and fixing false ceiling with 7.5 mm thick PVC plain panel board ceiling of approved quality in aluminium frame work with necessary screws etc complete (aluminium frame work shall be paid separately) | 89 | 346.5 | sqm |
| 90 | 90 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer | 90 | 929.09 | sqm |
| 91 | 91 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete | 91 | 927.09 | sqm |
| 92 | 92 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work | 92 | 927.09 | sqm |
| 93 | 93 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture | 93 | 604.261 | sqm |
| 94 | 94 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C | 94 | 112 | points |
| 95 | 95 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required Group C | 95 | 51 | points |
| 96 | 96 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 96 | 600 | m |
| 97 | 97 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 97 | 100 | m |
| 98 | 98 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm | 98 | 100 | m |
| 99 | 99 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | 99 | 320 | m |
| 100 | 100 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm | 100 | 720 | m |
| 101 | 101 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm | 101 | 100 | m |
| 102 | 102 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch | 102 | 84 | each |
| 103 | 103 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet | 103 | 84 | each |
| 104 | 104 | Supply and fixing RJ45 Data socket on the existing modular plate & switch box and giving necessary connections as required | 104 | 28 | each |
| 105 | 105 | Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable | 105 | 1820 | m |
| 106 | 106 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) | 106 | 4 | each |
| 107 | 107 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) | 107 | 4 | each |
| 108 | 108 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) 4 4 | 108 | 4 | each |
| 109 | 109 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module 2 | 109 | 28 | each |
| 110 | 110 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module | 110 | 20 | each |
| 111 | 111 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module | 111 | 20 | each |
| 112 | 112 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface | 112 | 28 | each |
| 113 | 113 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface | 113 | 20 | each |
| 114 | 114 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface | 114 | 20 | each |
| 115 | 115 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | 115 | 40 | each |
| 116 | 116 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. | 116 | 10 | each |
| 117 | 117 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. | 117 | 88 | each |
| 118 | 118 | Supplying and fixing PVC batten/ angle holder including connection etc. as required | 118 | 4 | each |
| 119 | 119 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door | 119 | 3 | each |
| 120 | 120 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | 120 | 36 | each |
| 121 | 121 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required | 121 | 5 | each |
| 122 | 122 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps \"C\" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. | 122 | 2 | each |
| 123 | 123 | Supplyirig and fixing following rating, double pole, (single phase and neutral), 240V, RCBO, having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25A DP RCBO,30 mA | 123 | 3 | each |
| 124 | 124 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp | 124 | 120 | m |
| 125 | 125 | Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.<br>2C x 6 Sq.mm - Cu. | 125 | 2 | each |
| 126 | 126 | Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. | 126 | 1 | each |
| 127 | 127 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) | 127 | 120 | m |
| 128 | 128 | Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. | 128 | 111 | each |
| 129 | 129 | Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep | 129 | 4 | each |
| 130 | 130 | Supply of following Exhaust fan in plastic frame working on 230 V A/C. with all accessories etc as required. 250 mm Sweep light duty exhaust fan Make: Havells Ventilair or equivalent | 130 | 4 | each |
| 131 | 131 | Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm sweep 5 star rated BLDC ceiling fan complete with 300mm down rod ,canopies, shackeles and blades working on 230V/240V single phase A/C Make: Havells Efficiencia Neo or equivalent | 131 | 40 | each |
| 132 | 132 | Supply of 20W LED tube light fitting housing made of Extruded thermal polycarbonate with 6500K colour temperature with duly wired up for use on 230 V AC. The fittings shall be directly on ceiling/ wall, including all accessories etc. as required. | 132 | 44 | each |
| 133 | 133 | Supply of Recess mounted LED down light fixture (IP20) housing made of Die cast Aluminium, acts as the Heat Sink.Efficacy greater than 95 Lm/W, have 1140 lumen output, 6500K colour temperature suitable for intdoor applications with 12W LED, including all connections etc as required. Make - Wipro Helios( LD90-141-XXX-65-XX ) or equivalent. | 133 | 4 | each |
| 134 | 134 | Supply of Recess mounted LED down light fixture (IP20) housing made of Die cast Aluminium, acts as the Heat Sink.Efficacy greater than 95 Lm/W, have 1425 lumen output, 6500K colour temperature suitable for intdoor applications with 15W LED, including all connections etc as required. Make - Wipro Helios( LD90-191-XXX-65-XX ) or equivalent. | 134 | 59 | each |
| 135 | 135 | Supply and fixing 9W Led bulb in existing fitting | 135 | 4 | each |
| 136 | 136 | Supply of 10W LED mirror light, housing made of Co-extruded channel in thermally conductive material with plastic with IP 20 protection, have 100 lumens/watt and 6500K colour temperature, operating frequency 50 ± 3% Hz, with duly wired up for use on 230 V AC etc. as required. Make - Wipro Trim LED neo or equivalent. | 136 | 4 | each |
| 137 | 137 | Supply, installation, testing and commissioning of 5 kVA, Single phase input, Single Phase output,UPS system with 30 minutes back up, 12v 16 numbers 26Ah SMF batteries including all accessories, cabling etc as required . | 137 | 1 | each |
| 138 | 138 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid | 138 | 4 | each |
| 139 | 139 | Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge | 139 | 4 | no |
| 140 | 140 | OD Derived from 17.7.1<br>Providing and fixing Under counter wash basin with C.I. brackets, C.P. brass pillar taps,C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require <br>Make:Parryware/Equivalent\"<br> | 140 | 4 | each |
| 141 | 141 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gms | 141 | 4 | no |
| 142 | 142 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore | 142 | 4 | each |
| 143 | 143 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore | 143 | 12 | each |
| 144 | 144 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2 | 144 | 5 | m |
| 145 | 145 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2 | 145 | 14 | m |
| 146 | 146 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 | 146 | 4 | m |
| 147 | 147 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall | 147 | 2 | m |
| 148 | 148 | Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall | 148 | 30 | m |
| 149 | 149 | Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall | 149 | 30 | m |
| 150 | 150 | Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2 | 150 | 2 | m |
| 151 | 151 | Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 | 151 | 100 | m |
| 152 | 152 | \"OD Derived<br>Providing , fixing , testing and commissioning pvc multy inlet (110x75x50x50x50) floor trap of self cleansing design with or without vent arm complete, including cost of masonry or concrete supports cutting and making good the walls and floors where ever required\"<br> | 152 | 8 | each |
| 153 | 153 | \"OD Derived<br>Providing, fixing, testing and commissioning at site 100x100 mm square C.P.cast brass or stainless steel Grating Cover with protection from cockroaches of matching size of multi inlet or \"\"P\"\"trap complete in all respects.\"<br> | 153 | 8 | each |
| 154 | 154 | OD Derived<br>Providing and fixing GI slotted rail of approved design. projecting 75 mm outside the wall surface and fixed on wall with 2 nos, 6/8 mm dia expansion hold fasteners, including drilling necessary holes in brick wall / CC / RCC surface and the cost of bolts included. The pipes shall be fixed to the already fixed brackets with the help of 8 mm galvanised GI \"U\" bolts of specified shape and shall be fixed with GI nuts, bolts, & washers of suitable size, one bolts on each side of the pipe. | 154 | 25 | m |
| 155 | 155 | \"OD Derived<br>Supply and fixing of 600x600mm DI medium duty manhole cover of class B-125\"<br> | 155 | 6 | each |
| 156 | 156 | 150x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | 156 | 1 | each |
| 157 | 157 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow | 157 | 2 | no |
| 158 | 158 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow | 158 | 4 | no |
| 159 | 159 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend | 159 | 2 | no |
| 160 | 160 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Door Tee | 160 | 4 | no |
| 161 | 161 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl | 161 | 2 | no |
| 162 | 162 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Socket /coupling | 162 | 4 | no |
| 163 | 163 | \"OD Derived<br>Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Y\"<br> | 163 | 4 | each |
| 164 | 164 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow | 164 | 4 | no |
| 165 | 165 | Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow | 165 | 4 | no |
| 166 | 166 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend | 166 | 2 | no |
| 167 | 167 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee | 167 | 4 | no |
| 168 | 168 | Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl | 168 | 2 | no |
| 169 | 169 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling | 169 | 20 | no |
| 170 | 170 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes | 170 | 25 | m |
| 171 | 171 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes | 171 | 10 | m |
| 172 | 172 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes | 172 | 45 | m |
| 173 | 173 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes | 173 | 42 | m |
| 174 | 174 | OD Derived from 18.18.2<br>\"Providing and fixing ball valve (brass) of approved quality of following sizes.<br>20mm dia <br>Make: Zoloto/SKS/Cim/Equivalent\" | 174 | 4 | each |
| 175 | 175 | OD Derived from 18.18.3<br>\"Providing and fixing ball valve (brass) of approved quality of following sizes.<br>25mm dia <br>Make: Zoloto/SKS/Cim/Equivalent\" | 175 | 2 | each |
| 176 | 176 | OD Derived from 18.18.3<br>\"Providing and fixing ball valve (brass) of approved quality of following sizes.<br>32mm dia <br>Make: Zoloto/SKS/Cim/Equivalent\" | 176 | 1 | no |
AI Tender Summary
Tender Timeline
Dec 22, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedDec 30, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 01, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender