Special Repair/Replacement Of Tube Well At Pump House No . 15 And Allied Works Of Water Supply Network Under Ge ( West ) Jalandhar Cantt . Please Refer Tender Documents, Jalandhar Cantt-Punjab

Military Engineer Services-MES has published Special Repair/Replacement Of Tube Well At Pump House No . 15 And Allied Works Of Water Supply Network Under Ge ( West ) Jalandhar Cantt . Please Refer Tender Documents. Submission Date for this Tender is 02-03-2021. Water Pipe Line Tenders in Jalandhar Cantt Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

26353113
Corrigendum : Special Repair/Replacement Of Tube Well At Pump House No . 15 And Allied Works Of Water Supply Network Under Ge ( West ) Jalandhar Cantt . Please Refer Tender Documents
Open Tender
Indian
Punjab
Jalandhar Cantt
02-03-2021

Tender Details

Special Repair / Replacement Of Tube Well At Pump House No . 15 And Allied Works Of Water Supply Network Under Ge ( West ) Jalandhar Cantt . Please Refer Tender Documents

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Jan-2021 CORRIGENDUM NO.1 Date 16-01-2021
2 13-Jan-2021 CORRIGENDUM NO.2 Date 23-01-2021
3 13-Jan-2021 CORRIGENDUM NO.2 Date 23-01-2021
4 20-Jan-2021 CORRIGENDUM NO.3 Date 06-02-2021
5 03-Feb-2021 CORRIGENDUM NO.4 Date 13-02-2021
6 11-Feb-2021 CORRIGENDUM NO.5 Date 23-02-2021
7 23-Feb-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-03-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 64000.0 /-
Tender Value
INR 32 Lakhs /-

BOQ Items

Name of Work: Spl repair for replacement of tube well at pump house No. 15 and allied works of water supply network under GE (West) Jalandhar Cantt
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L for boring with reverse rotary rig circulation method including electronic logging through any kind of stratas of soil/rocks for drilling not less than 650 mm dia hole for depth not exceeding 75 mtrs deep below ground level by keeping sufficient space for pea packing gravel complete all as specified. 75 RM
2 2 All as per Srl item No 1 here-in-before, but depth exc 75 meters and not exc. 150 meters below ground level complete all as specified 75 RM
3 3 All as per Srl item No 1 here-in-before, but depth exc 150 meters and not exc. 225 meters deep below ground level complete all as specified 75 RM
4 4 All as per Srl item No 1 here-in-before, but depth exc 225 meters and not exc. 300 meters deep below ground level complete all as specified 75 RM
5 5 Supplying, assembling fixing and lowering into bore hole 350 mm (14") dia MS casing pipe with 8 mm wall thickness externally threaded and socketed ERW in random length of 6 mtr or as required duly ISI Marked including necessary fittings and jointing upto 90 mtrs depth from ground level and painting with two coats of anti corrosive paint on external surfaces of pipe before lowering complete all as specified and directed. 90 RM
6 6 All as per Srl item No 5 here-in-before but size of MS casing pipe 250mm (10") with 8 mm wall thickness ISI marked and jointing the MS casing threaded and socketed alongwith arc welding complete at depth exceeding 90 mtr but not exceeding 300 mtr below ground level all as specifed and directed. 100 RM
7 7 Supplying assembling fixing and lowering exceeding 90 mtr but n.exc 200 mtr below ground level low carbon galvanized strainer 250mm (10") bore minimum wall thickness 8 mm including screwed mild steel socket as per latest ISI having slots to suit the size of sand grain including fitting jointing the MS casing and MS Pipes 250 mm bore by welding of 30 x 6 mm FI strips 45 cm long 3 Nos complete all as specified and directed 110 RM
8 8 Supplying and fixing 8 mm thick MS bail plug of 250mm dia x 600 mm long with strong iron hook, screwed & welded to the casing pipe (length of pipe required to be fixed with bail plug will be measured and paid for separately under respective item) complete all as specified. 1 Each
9 9 Supply, fixing and lowering into bore hole centering guides made out of MS flat 50 x 6 mm made to shape with two rings at 75 cm apart and three No ribs suitable for 350/250mm bore pipe complete all as specified and directed by Engineer-in-Charge 1 Set of three
10 10 Supply and fixing MS reducer of wall thickness 8 mm screwed both end 350 x 250 mm size of length 600 mm including jointing threaded and socketed alongwith electric arc welding complete all as specified and directed by Engineer-in-Charge. 1 Each
11 11 Supply and fixing well cap 350 mm bore having internal threads and with welded iron handle of 20 mm dia MS round complete all as specified and directed by Engineer-in-Charge. 1 Each
12 12 Supply and fixing housing clamp 90 cm long made out of MS flat iron 100 mm x 10 mm for 350 mm dia casing pipe with necessary MS bolts, nuts and washers at ground level complete all as specified and as directed by Engineer-in-Charge. 1 Set of two
13 13 Supplying and packing pea gravel of size 3.00 mm to 4.00 mm all around the casing pipe and slotted pipe in the well bore to entire depth complete all as specified (volume of pea gravel shall be measured as space between bore well and outer dia of pipe) 40 Cum
14 14 Supplying and fixing 80 mm bore GI Pipe medium grade 6 mtr long 4 Nos in the angular pace on four sides of the borewell and 30 cm above the ground level with suitable size GI cap at gound level for feeding pea gravel complete all as specified (Cost of gravel feeding is not included in this item). 1 Each Job
15 15 M&L for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in block mass concrete below ground level all around the bore level all as specified and directed. 5 Cum
16 16 Supplying and fixing strata box with openable sheet glass shutter 3 mm thick and having internal dimension 150 mm x 100 mm x 1.5 mtr complete with soil sample obtained from various depths of boring after every interval of 10 mtrs with particulars like name/number of tube well location and depth of strata duly written including provision of strata charts complete all as specified and direct by Engineer-in-Charge. 1 Each
17 17 M&L for development of the bore well with high capacity air compressor for not less than 8 hrs till the water become sand or silt free including removing of surplus soil mud to a distance not exceeding 50 mtr and depositing as directed & making the site clear all as directed. (Air compressor high capacity 600 Cu ft/per miute and 600 PSI alongwith connected tools and plants required for the development will be arranged by the contractor. Note : Cost of fuels, electrical supply etc are also to be included in the item rate quoted) 1 Each Job
18 18 M&L for Yield testing and stabilizing of the tube well by means of electric driven pumping set of suitable capacity (the discharge shall be measured by providing orifice system of 'V' notch fixed to steel tank of adequate capacity) (Pumping set and reqd equipments shall be arranged by the contractor under his own arrangements) and testing of water from NABL approved Govt Laboratory and submission of report complete all as specified and directed.. 1 Each Job
19 19 Supply and fixing (in replacement) of submersible cable PVC insulated, PVC sheathed, industrial, multi stranded, copper conductor 3 core, 16 sq mm flat, minimum number of strands 126 Nos and nominal dia of each strand not less than 0.4 mm, 1100 volt grade conforming to IS 694/1990 completed all as specified , 250 RM
20 20 Supply, install, testing and commissioning of submersible motor cum pump (Pumpset), Electric driven 415V, AC, 50 Hz, 3 pole suitable for 200/250 mm dia bore well (casing pipe size 300/350 mm) complete of capacity 25 HP/18.5 KW, 5 stage pump, stainless steel body, delivery pipe size 100 mm, discharge 1525-725 LPM at 45-100 Mtr head, including provn of suitable size connecting piece/distance piece suitable to connect the pump with column pipe- 01 No necessary arrangement for welding/fixing with pump end all as specified and directed. 1 Each Job
21 21 Supplying & fixing GI column pipe 100 mm dia, heavy duty, "C" class with both end flanged and drilled 3 mtrs long including connecting to mainpipe line complete all as specified and directed. \nNote : The cost of nuts, bolts, washers packing materials and pressure gauge shall be deemed to be included in unit rate quoted by the contractor) 15 Each
22 22 Supply and laying jointing and testing 100 mm (4") dia, ductile iron pressure pipes with flanged ends centrifugally cast conforming to IS-8329-2000 suitable for rubber/gasket joints including joints and jointing materials Class "K-9" in any length, laid in trenches complete all as specified and as directed. 55 RM
23 23 M&L for fittings for flanged pipes such as bends of any type, radius and angle tapers any type (straight, bend increasing, decreasing or double sockets etc) Tee pieces single branch 'Y' junction, double branch, cross( all sockets or socket and spigot) collars, caps and plug size upto 150 mm bore, all as per IS 1538-1993, ISI marked complete all as specified). 225 Kg
24 24 M&L for joints with rubber gasket for flanged pipe of bore for 100mm size DI pipe line complete all as specified and directed. 10 Each
25 25 S&F Non-return valve/Reflux valve with bypass arrangement 100 mm dia, Cast iron, screwed/flanged both ends, nuts, bolts, washers gaskets etc as required at site ISI marked complete all as directed. 1 Each
26 26 Supply & laying of cast iron air release valve with two air outlets 80 mm dia bore and fixing in cast iron water supply mains on 100 dia bore pipe line complete all as specified and directed. 1 Each
27 27 Supply, install, testing and commissioning chemical dozing system having plastic chemical solution tank with lid of capacity 250 Ltrs fitted on it with one electronic positive displacement diaphragm type motor pump operating at 230V, 50 Hz, AC supply, discharge capacity 0-25 LPH, minimum pressure 3 Kgs/Sq CM with connected accessories like NRV, in-built ARV, foot valve with stainer fitted on pump suction assembly / wall mounting bracket with fixing accessories, one tank level switch fitted on pump suction assembly to stop the pump when liquid in tank falls below a certain level and lights a red LED on the pump, adjustable stroke length and frequency, volume of tank 250 ltrs, including high speed single phase motor of power 0.37 KW mixer/agitator with stainless steel impeller and shaft fitted with worm gear reducer assembly including provision of new power cable PVC insulated 1.5 sqmm x 3 core copper conductor cable from panel/socket to motor drawn through PVC conduit not less than 20 mm bore medium grade, fixed to wall/floor with suitable size clamps and screws and provn of 01 x MCB SPN, 6 to 32 Amp, C Series and 02 x MCB SP 6 to 32 amps fitted in a sheet metal enclosure/MCB DB 4 way single door fixed on a wooden board base of suitable size complete connection and testing all as specified and directed. 1 Each Job
28 28 S&F in position 100 mm bore Cast Iron Sluice Valve, double flanged complete with brass spindle iron wheel handle clock wise closing with drilled hole flanged heavy duty PN 1.6 conforming to IS-13095, including rubber gasket, nut, bolts, washers all as specified and directed. Note :- DI Specials/fittings will be measured separately under relevant items. 1 Each
29 29 S & F PVC tubing 15 mm dia heavy duty fixed to wall/floor by means of suitable size PVC U clamps at an inetrval of 600 mm complete all as specified and directed 5 RM
30 30 Supply & fix pressure gauge 100 mm dia with ball valve of pressure 25 Kg/Sqcm all as specified and directed. 1 Each
31 31 Supply and fixing water level indicator electronic type suitable for over head reservoirs incl provn of PVC copper cable 0.5 sqmm 10 core from OHT to pump house and water level sensor 07 Nos complete set all as specified and directed by Engineer-in- charge 1 Each Job
32 32 Cutting of existing underground cast iron pipe 150/100mm dia including provn of fittings viz, Tee-01 No, tail piece -2 Nos and required jointing materials to establishing joint to connect with existing pipe line including earth work, returning filling, removal complete all as specified and directed. (DI Specials will be measured and paid separately) 1 Each Job
33 33 Lifting / taking up of defective submersible pumping set of any capacity i.e 20 HP to 25 HP from deep tube well and dismantling of connected rising main i.e non return valve/bend or both (if required) etc from delivery of pump set, lifting of column pipe fixed with pumping set, unscrewing of column pipes from socket / flange, required No of times untill the pumpset lifted from borewell, cutting of welded strip unscrewing of cable holding clamps and disconnecting of submersible cable joint complete all as directed by EIC. \nNote: Old defective pumpset (Motor cum pump) will be deposited to AGE E/M store yard. 1 Each Job
34 34 Taking down carefully aluminium / copper point wiring (light / fan / socket or power) complete including fitting such as switches, ceiling roses, socket, light fittings, regulators etc complete and making good disturbed surfaces of walls, floors complete all as specified and directed. 14 Per point
35 35 Material & labour for concealed point wiring complete with single core 1.5 Sqmm (nominal area) PVC insulated and unsheathed cable 1100 volts multistranded, copper conductor cable (FRLS) drawn through and including PVC concealed conduit not less than 20mm dia bore medium grade (ISI marked) and accessories like bends, tees, junction boxes etc, fix on wall or ceiling surfaces all as specified including 1.5 sqmm , FRLS, copper multistranded cable as earth wire including sunken pressed steel terminal boxes and bakelite white/ coloured top sheet cover 3.0 mm thick , for One light point controlled by one way switch complete all as specified and directed. 11 Per point
36 36 All as per srl item No 35 here-in-before but one fan point controlled by one way switch complete all as specified and as directed 1 Per point
37 37 All as per srl item No 35 here-in-before but for 3 pin socket outlet, 5 Amps on same board complete all as specified and as directed 1 Per point
38 38 All as per srl item No 35 here-in-before but for 3 pin socket outlet, 5 Amps on independent board complete all as specified and as directed 2 Per point
39 39 Supply and fix switch piano flush type, 5 Amps, 240V AC, single pole, one way complete all as specified and directed. 15 Each
40 40 S & F ceilling rose surface type bakelite 65x50mm three terminal all as specified and directed 12 Each
41 41 S&F socket outlet type 2 in 1 3/5 pin 5 Amps all as specified and directed 2 Each
42 42 S & F stepped socketed type electronic fan regulator flush type five steps 230/250 volts and connecting up complete all as specified and directed 1 Each
43 43 S&F LED batten type fitting, 22 watt, 4 feet length with aluminium housing, 230 vlts, AC, 50 Hz, Colour temp 6500 Kelvin connection with all accessories all specified & directed. 5 Each
44 44 M&L submain wiring complete with 2 x 4 Sqmm + 1 x 4.0 Sqmm earth wire PVC insulated and unsheathed cable with multistranded copper conductor in PVC conduit ISI marked , fixed on wall/ceiling/ passing through cable tray all as specified & directed. \nNote : 2 Runs of PVC copper cable of size 4 sqmm and 1 Run of 4.0 sqmm PVC copper cable and 1 Run of PVC conduit will be measured as one run. 18 RM
45 45 Supply and fix sheet metal enclosure powder coated double door in flush fixed position suitable for MCB DB 4 way SPN, 230V, AC, 50 HZ complete all as specified and directed. 1 Each
46 46 S&F MCB DP/SPN, 32 Amps, 230 volts 50 HZ complete all as specified and directed. 1 Each
47 47 S&F MCB SP, 6 to 32 Amps , 230 volts 50 HZ complete all as specified and directed. 2 Each
48 48 S&F 45 watt energy effecient LED street light fitting complete with high power LEDs as light source, prewired, mounted with new GI bracket made to shape, fixed with suitable size 2 Nos of clamps, nuts/bolts/washers etc and connecting including taking down unserviceable HPSV/MH/FTL light fitting of any rating all as specified and directed. Make : Crompton Greaves Cat Part No LSTP 45 CDL or equivalent in make as mentioned in Appx 'B' 6 Each
49 49 Disconnecting and taking down the existing LT panel board and M&L for fabrication, testing and commissioning of LT power distribution panel board of suitable size made out of CRCA sheet 3.15 mm thick Outdoor type totally enclosed with hinged doors, weather and water proof as per IS-8623, fixed on MS rail for safe standing on floor with suitable size PCC block for fixing the panel on ground, aluminium bus bar with half neutral, mounted on insulators suitable for 3 phase 4 wire LT, AC, 50HZ, 433 volts, 200 Amps, capacity and indication lamp (Red,Yellow, Blue) complete with necessary locking arrangements all as specified and directed including painting with two coats of synthetic enamel paint over a coat of red oxide primer, internal electric connections as required and provision of the following:-\n(a) MCCB 200 A, 3 pole 25 KA breaking capacity, adjustable overload and short circuit setting, 415 volts - 01 No\n(b) MCCB 125 A, 3 pole 25 KA breaking capacity, adjustable overload and short circuit setting, 415 volts - 02 No\n(c) MCB 6-32A, triple pole, 230 volts - 02 No\n(d) On-line change over switch cubical type, 125 Amp, TPN, 415V, AC- 01 Nos \n(e) Automatic star delta starter for 50 HP/37 KW submersible motor with relay range 45 - 75 Amp with phase reversal protection, single phase preventor relay, timer etc - 01 Nos (f) Mobile starter module / pump controller, 3 phase, 415V, 50 Hz AC supply suitable to controll pump starter from remote location through mobile handset, capable to display voltage, ampere. motor ON/OFF status etc with overload, single phase, phase reversal protection and connection with starter complete - 01 Nos \n(g) Multi function meter 3 phase, LCD display-01 No (h) Indication lamp set of three - 02 set 1 Each Job
50 50 Material and labour for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of theplate not less 1.5 mtr deep below normal ground level connected to GI earth wire 4mm dia connected to earth plate earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continuous earth wire on pole, testing the earthing after completion complete all as specified and directed. \nNote :- PCC chamber shall be (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC (1:2:4) type B-1 cover slab reinforced with 8mm dia TMT steel bars @ 100mm c/c both ways complete all as specified and directed. 1 Each Job
51 51 M & L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI earth strip size 25 x 4 mm as earth lead connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 print and as directed . 4 Each Job
52 52 S&F GI earth strip 25 x 4 mm laid in trenches/fixed to walls on epoxy insulators with screws etc and connecting complete all as specified and directed. 8 RM
53 53 Supply & laying (in replacement) jointing, testing and commissioning the XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross sectional area Size 70 Sq mm, 3.5 Core including connecting the same with existing panels with required cable glands , thimbles/ lugs as required at site complete all as specified and directed. 50 RM
54 54 Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and getting out complete all as specified and directed by Engineer-in-Charge. 13.5 Cum
55 55 Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer compete all as specified and directed by Engineer-in-Charge.\n 8.5 Cum
56 56 Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge. 4.9 Cum
57 57 Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified. \nNote : Punned down thickness shall be measured. 4 Cum
58 58 Supply and lay burnt bricks sub class 'B' standard size laid across the cable in trenches as protection to the cable all as specified and directed. 0.43 Per 1000 Nos
59 59 Supply, install, commissioning and testing complete silent Diesel Engine driven generating set capable of delivering 40 KVA developing 56 BHP @ 1500 RPM or of next higher capacity as available/manufacturered 415 volts (AC 3 Phase, 4 wire system of supply) 50 HZ at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching parts or as recommended/provided by the manufacturer on a common base frame and thereafter installed in the CPCB approved acoustic enclosure. (The complete set conforming to and test certificates as per CPCB norms all as specified complete with AMF control panel standardized by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement flexible exhaust pipe complete and shall comprise the following :- \n(a) Engine (Prime Mover) : Diesel engine 1500 RPM of minimum 56 BHP Turbo charged liquid cooled, 12 volts electric battery start, complete with fly wheel and all standard fittings/fixtures as per manufacturing design including suitable Engine Control/Monitoring Panel. Comprising the following :- (i) Microprocessor based gen set controller for metering, monitoring governing and protection (ii) Engine protection for low Lub oil pressure, high coolant temperature (alarm & shutdown) (iii) Alternator protection parameters like under voltage, over current, under frequency, load imbalance (alarm & shut down) (iv) relay drivers for remote annunciation (v) cyclic cranking (vi) Auto/Manual starts/ stops (vii) Alternator trim adjustment from the front key pad (viii) Operates within a temperature range 0.50°C and humidity into 95% (ix) Genset metering parameters like lub oil pressure, coolant temperature, engine speed (rpm), run hours, DC voltage, 3 phase volts and 3 phase amperes, frequency, KW, KVA.Power factor (x) Safety controls :- Engine low lube oil pressure, high water temperature and over speeding of engine (m) Coupling arrangement flexible coupling fly wheel to suit flexible coupling fly wheel housing. 1 Each
60 59.01 (b) Alternator Alternator AC alternator, 3 phase, 415 volts, 4 wire rated line current for output 40 KVA PF 0.8 1500 RPM insulation class enclosure/SPDP self excited, self regulated brushess, complete with AVR with +1% voltage regulation directly coupled to and match the above engine. Make of alternator shall be Kirloskar/CROMPTON/STAMFORD. (c) Base plate : Made out of structural steel as per manufactuer's recommended design/specifications. (d) Acoustic Enclosure Provision of an integral type approved/certified acoustic enclosure (Make of enclosure shall be as per CPCB norms for the DG sets to restrict the noise level to 75 db at one meter distance and temp rise within canopy shall not exceed 7 degree centigrade beyond ambient temp. It shall be made of 16 SWG or manufacturer's standard norms CRCA sheet with powder coated finish on outside and provided with non igniting fire retardant foam as acoustic material. The doors & glass window shall be as per manufacturers design. The base frame shall be of ISMC. It shall also include the follwing :-\n(e) Silencer : Absorption type, residential and exhaust silencer. (f) Internal wiring with PVC copper conductor cable IS 694 marked. FRLS in conduit and fluorescent lamp fittings (g) Fuel tank of 16 hours capacity but not less than made of 14 SWG CRCA sheet duly powder coated and provided with float, gauge and fuel float switch. (h) One Nos 12V x 180 AH 25 Plates E41 batteries (As recommended by manufacturer)\nNote (i) Catalogues Operation and maintenance manual, spare parts list overhauling manual 03 sets shall also be supplied within cost quoted. (ii) Maintenance chart and manufacturer instruction shall be displayed on wooden board including catlog board within area all cost quoted. (iii) Foundation for mounting of DG set shall be done as per manufacturer design within overall cost quoted. (iv) Pre-commissioning test shall be carried out by rep of AO and POL for testing shall be arranged by contractor within overall cost and deemed to be included in the rate quoted.
61 60 Taking down old unserviceable open type DG Set with fuel tank and silencer of any capacity after cutting nuts/bolts, lifting through crane without damage to the equipment and dismantling the change over switch unit after disconnecting the electric supply and despositing at MES Store yard complete all as specified and directed. 1 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail