| 1 | 1 | De-watering of Lake before start of any construciton activities like excavation ,filling etc to make it dry and suitable for construction .including hire charges of suitable nos of Pump, D.G. Set including POL, Operator , change over switch,Control panel etc. as required etc. | 1 | 24 | Hours |
|---|
| 2 | 2 | Construction of Impervious layer in all type of soil in multiple layers including preparation of bottom surface by removing all sharp edges ,stone particles ,wood particles and providing & laying 300 GSM PP non -Woven geotextile in first layer and 1.0 mm thick HDPE liner over first layer ,100 mm thick murrum filling over HDPE membrane ,murrum shall be free from any debris ,wood particles ,grass partical as per technical specification ,and providing and laying precast cement concrete block 100 mm thick over murrum base . | 2 | 2200 | Sqm |
|---|
| 3 | 3 | Flooring with Natural stone in crazzy pattern of approx. Size 125x125x75 mm (thick) laid on 25 mm average thick cement mortar 1:3 ( 1 cement : 3 Coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the stone, laid in approved pattern complete in all respect as per direction of Engineer-in-charge. | 3 | 300 | Sqm |
|---|
| 4 | 4 | Providing and fixing 80 mm thick Grass paver in parking areas including all necessary requirement as per direction of engineer in charge | 4 | 200 | Sqm |
|---|
| 5 | 5 | Supplying and filling Gravel rounded in shape in areas as per architectural drawing. | 5 | 58.4 | cum |
|---|
| 6 | 6 | Supply and Fixing Red colour Sand Stone Bench | 6 | 20 | each |
|---|
| 7 | 7 | Construction of Gazebo as per architectural drawing | 7 | 1 | Nos |
|---|
| 8 | 8 | Construction of FRP Pergolas as per architectural drawing | 8 | 1 | Nos |
|---|
| 9 | 9 | Solid Waste Management for entrie premises including providing composit pit , collection pit, dry & wet Litter bin ,bins for food outlet ,paper bin ,container for waste cooking oil, waste bin for toilet,Basket for sorting waste,Waste Carting arrangement etc. | 9 | 1 | Nos |
|---|
| 10 | 10 | Supplying & Installation of approved Make required capacity 3 phase, 50 Hz, 415V, Open Well Submersible pump, with Control Panel Starter with Dry Run Protection, single phase preventer, connections, etc. as required as per specifications but including dischage Pipe and connection cable.\nHead Mt 10, Discharge LPM 2000 \n | 10 | 2 | Nos |
|---|
| 11 | 11 | Transfer Pumps from Canal (rent basis) of 390 m3/h @ 10 m head | 11 | 24 | Hour |
|---|
| 12 | 12 | Providing and fixing electronic water level controller with IP 55 enclosure including sensor probes & interconnecting control cables for auto ON/OFF operation of open well submersible pumps at sr. no 10 above. | 12 | 1 | Set |
|---|
| 13 | 13 | Pressure Gauge with isolating valve at pump outlet | 13 | 5 | Nos |
|---|
| 14 | 14 | Providing, installation, testing and commissioning of Full Bore Electromagnetic flow meter with factory calibrated, Regular Power Operated, flanged connection, Flow sensor, Indicator, transmitter and totaliser with all accessories viz. surge arrestor, associated cables, cabinets, hardwares, etc complete as per following specifications:\nFlow Meter/ Sensor:\nDC pulsed type, IP 68 Protection, Flanged process connection as per IS 1538 or equivalent standard, \nSS304/ Metallic Alloy Flow Tube, \nSS316/ SS 316 L/ Hastelloy Sensor, \nSS316/ Hastelloy Grounding Ring/ Inbuilt Grounding Electrode, \nNeoprene/ Polyurethane/ Hard Rubber/ Rilsan lining, \nSS304/ Die Cast Aluminium/ Carbon steel with Anticorrosive Paint Coil Housing with Junction Box, \nCS flanges.\nFlow Transmitter/ Converter ( Remote Field Mounted):\nMicroprocessor based, Modular design, \n2 line LCD for indication of actual flow rate, forward, reverse, sum totaliser display,\n ±0.5% accuracy at 0.3 to 4 m/sec velocity,\n 4 to 20 mA with HART, one scalable pulse, one status output, \nIP 67 protection, \nDie cast aluminium/ polycarbonate/ SS316 with Anticorrosive Paint/ PU finish with glass window enclosure, Inbuilt EEPROM and Data Logger,\n10 meters cable length for sensor to transmitter communication.\n100 mm Nominal Bore. | 14 | 1 | each |
|---|
| 15 | 15 | SITC of drinking fountain Outdoor with, Bi-level drinking water fountain two at higher level another at lower level for kids and low Hight Person push pad should have MDCU29 Mechanical Activated.Reddii Model oasis along with round shape recipient with Hight 1168 mm X 102 mm dia round shape ss 304, Día of the Raddii will be 356mm size, Openable plate for easy service at the lower part of the system. Drain and inlet connection will be under ground at the lower part of the drinking water fountain, 100 Micron strainer , SS bubbler guard , and operation between 20-120 PSI / 3KG Water Pressure, stainless steel brushed finish, Water Ways are lead free material, Fountain should be designed to eliminate splashing and standing water, ANSI A117.1-1992Listed by under writers Laboratories to US and Canada. bubbler certified by TUV and GRIHA, SHALL Complies with ANSI/NSF 61. providing & fixing at different location (Excluding Civil work).Model- FS2-F140R- Make/ Oasis/Filtrin/Sunrock | 15 | 1 | Nos |
|---|
| 16 | 16 | Providing & Fixing Water coolers with inbuitl RO including all necessary fittings approved by Engineer -in -charge | 16 | 1 | Nos |
|---|
| 17 | 17 | Supply, Installation, Testing & Commissioning of 2MP Outdoor IR IP Dome Camera with 1/2.9\" CMOS sensor, 2 MP (1920x1080p) @ 25/30fps or better, Video Compression H.265,M-JPEG, Fully Configurable Quad stream,AVF Lens (Zoom/ focus) 3 to 10mm DC Iris , IR with 30m IR distance, Two way full duplex Audio Alarm: 1 In/ 1 out, Analog video output, 60s pre alarm recording, 512 GB Memory SD card support with ANR Feature as per detailed technical specifications | 17 | 5 | Nos |
|---|
| 18 | 18 | Supply, Installation, Testing & Commissioning of 42 Camera Recorder with VMS and shall support camera mentioned analytics with minimum 16 TB Storage support | 18 | 1 | Nos |
|---|
| 19 | 19 | LIU- Patch Cord Management System | 19 | 5 | Nos |
|---|
| 20 | 20 | Cat-6 - SITC of category 6S/UTP/ FTP cable, non plenum slate jacket 4 pair count length box with information outlet orange for CCTV/ Rack side. | 20 | 1500 | Mtrs |
|---|
| 21 | 21 | 8 Core OFC Cable - Single Mode Fiber Cable | 21 | 1500 | Mtrs |
|---|
| 22 | 22 | 22 U Surface Mount networking rack with H/W packet and one vertical power Strip with two Fan castor wheels, partition, Front Glass Doors & Rear MS perforated Door Lock & Key as per site requirement. | 22 | 1 | Nos |
|---|
| 23 | 23 | 4-Port PoE Switch | 23 | 5 | Nos |
|---|
| 24 | 24 | 16-Port Managed Switch | 24 | 1 | Nos |
|---|
| 25 | 25 | I&C and Cabling work Includin the conduits | 25 | 1500 | Mtrs |
|---|
| 26 | 26 | 6 Meter GI Camera Pole | 26 | 5 | Nos |
|---|
| 27 | 27 | Wireless Hardware Controller, should be ready for supporting 150 AP’s from day one with scalability for 500 AP support in future without adding any new hardware. Each controller (Primary and Redundant) should be able to support minimum 500 campus connected AP’s or more with support of seamless roaming access over L2/L3 network.. With 5 years warranty by OEM( As per Specification) | 27 | 1 | Nos |
|---|
| 28 | 28 | Indoor dual-band (5 GHz and 2.4 GHz concurrent) 802.11abgn/ac Wireless Access Point, dual ports, PoE support. (Specification As Given) | 28 | 5 | Nos |
|---|
| 29 | 29 | 4 Port Gigabit Managed PoE Switch with SFP Slot With 5 years warranty by OEM (Specification As Given) | 29 | 5 | Nos |
|---|
| 30 | 30 | 24 Ports Patch Panel - Loaded | 30 | 5 | Nos |
|---|
| 31 | 31 | 6 core fiber optic cable -metallic armoured\n/ csta single mode (Specification As Given) | 31 | 1500 | Mtrs |
|---|
| 32 | 32 | FC-APC single mode duplex fiber optic patch\ncord, 3 meter (Specification As Given) | 32 | 5 | Nos |
|---|
| 33 | 33 | Fiber Termination Box (Specification As Given) | 33 | 2 | Nos |
|---|
| 34 | 34 | CAT 6 UTP Cable Box (305Mtr) | 34 | 6 | Box |
|---|
| 35 | 35 | 550VA/600VA UPS with standard Battery Backup | 35 | 5 | Nos |
|---|
| 36 | 36 | 1.50 mm Electric Cable | 36 | 1500 | Mtrs |
|---|
| 37 | 37 | PVC Conduit-1\" (2MM) | 37 | 1500 | Mtrs |
|---|
| 38 | 38 | Internet Lease Line (ILL) - 45 Mbps | 38 | 1 | Nos |
|---|
| 39 | 39 | One time Installation & configuration charges for all above Components including laying, fixing, digging/ cutting (wherever required) ,training, documentation as per scope of Work & AIIMS's requirement with 3 years comprehensive onsite Service Support | 39 | 1 | Job |
|---|
| 40 | 40 | Micro Trenching for Cabling work | 40 | 1500 | Mtrs |
|---|
| 41 | 41 | Sub Feeder Pillars: (Location - Outdoor)\nSupplying & erecting IP 55 grade 150 x 90 x 75 cms section pillar fabricated from 14 Gauge thick joint less M.S. Sheet with angle iron legs 95 cms long made from 40 x 40x 6 mm thick. Jointless M.S. Angle with cable clamps to be buried in ground to have appropriate erection to work Uniform Until erected with cement concrete foundation and 45 cms high bricks work finishing with plaster etc. hinged double door with 4\" x 6\" vision panel covered with Mesh & V. panel overlapping with flap for meter reading internally supported on both side, with internal and outside looking arrangement with look and keys in duplicate 40 x 40 x 6 mm M.S. Angle of Two Nos. one is welded and other with nut and bolt for erecting Bakelite sheet. Painting the Section Pillar inside and out side with three tank powder coated paint. section pillar roof should be without joint with water leakage proof & tested as per IP 55 test & followed by IS 2147 of 1962.\n(a) Supplying & erecting approved make Four pole moulded case circuit breaker having breaking capacity ICU of 18 KA. at 415 V, normal current rating up to 63-80A with Fixed thermal & magnetic release suitable to work on A.C. Supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing. (1no)\nb) Supplying & erecting approved make Digital time switch having lithium cell 6 years operative and operate battery backup 1 channel day clock with 14 memory programme, suitable to operate on 240V + 5%, 16A with, floating contacts Minimum switching setup time 1 minimum & LCD display. Also comprised permanent ON/OFF switching. Programming switches & housed in fire proof thermoplastic enclosure & transparent cover erected as required with necessary connection erected as directed.\n(c) Supplying & erecting power contactor for time switch complete erected as per direction Cat III, [D] 4 pole 440V up to 63 A, protected by four pole miniature circuit breaker of approved make having breaking capacity ICU of 10 KA. at 415 V, normal current rating up to 63A suitable to work on A.C. Supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing.\n(d) Supplying & erecting Four pole Residual current breaker with overload protection (RCBO)/ miniature circuit breakers (MCB) having breaking capacity ICU of 10 KA. at 415 V, normal current rating upto 63 A suitable to work on A.C. supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing. (8 Nos.)\n(e) Supplying & erecting single pole miniature circuit breaker (SP MCB) having breaking capacity ICU of 10 KA. at 230V, normal current rating upto 16-32A suitable to work on A.C. supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing. (21 Nos.)\n(f) Providing and erecting busbar chamber confirming to IS-375 fabricated from 16 G.M.S. sheet, dust & vermin proof having hinged door with rubber gasket and necessary busbar supports with 100A Aluminium busbar having current density not more than 0.8 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour insulation tape for phase sequence, three phase & neutral each Suitable for following current capacity with necessary painting mounted on wall or pedestal frame of required size with necessary connections. | 41 | 5 | Nos |
|---|
| 42 | 42 | Tree Uplighter:\nSupplying, installation, testing and commissioning of LED Flood Light IP66 Single Piece Pressure Die Cast Aluminium Housing, High Power LEDs, System Wattage not exceeding 40 Watt (System Lumens > 3200 lumens) with PF >0.9 & voltage range of 140-270VAC, Narrow Beam 20-30-degree and wide Beam- 50-60 deg , Fixture shall operate in a temperature range of 0°C to 35°C, fixture must come with inbuilt surge protection of 2KV & should be extendable to 10KV with the help of external SPD. Min. System Efficacy – 80 lumens per watt, CRI > 70, CCT – 3000 K. Fixture must be BIS certified. | 42 | 24 | No. |
|---|
| 43 | 43 | Supplying, installation, testing and commissioning of 150mm height pedestal made of PCC having lockable arrangement for mounting the LED Flood luminaire in ground floor with GI cage painted with green colour above the luminaire having a provision cable entry and exit complete as required. | 43 | 24 | No |
|---|
| 44 | 44 | Supply, Installation, testing and commissioning of weatherproof Junction Boxes (with IP66 Protection) Suitable out door rated IP 55 Loop in loop out Box having a provision of the incoming cable of 4C x 16 sq.mm and 4C x 16 sq.mm & 3C x 1.5/ 2.5 sq.mm outgoing cable complete with glands and mounting arrangements required for light fixture connections at site. \nSize-150mm x 150mm x 60/75 mm depth/ as per requirement. | 44 | 24 | No. |
|---|
| 45 | 45 | Water Lake front Tree Uplighter\nSupplying, installation, testing and commissioning of Medium power architectural RGB LED flood light with housing material of Die-cast aluminium with Tempered glass cover, dark grey powder-coated finish, system wattage not exceeding 75W and system lumen output of not less than 2500 lumens. Fixture shall be available with architectural optics with choice of beam angles of Narrow 8°-12, Medium 15°-20° and Wide 35°-40°.Suitable for DMX/Ethernet. Fixture shall have voltage for Auto-ranging 100V to 240V 50 / 60Hz input. Lifetime should be at least 50,000 burning hours at L70 at 25 degree centigrade with total IP66 protection. fixture operating temperature range -40ºC to 40ºC (-40ºF ~104ºF) & fixture shall equipped with mechanical impact of minimum IK06. fixture must come with inbuilt surge protection of 2KV & should be extendable to 10KV with the help of external SPD. Fixture must be UL / cUL, FCC Class A certified. | 45 | 18 | No. |
|---|
| 46 | 46 | Supplying, installation, testing and commissioning of 150mm height pedestal made of PCC having lockable arrangement for mounting the LED Flood luminaire in ground floor with GI cage painted with green colour above the luminaire having a provision cable entry and exit complete as required. | 46 | 18 | No |
|---|
| 47 | 47 | Supply, Installation, testing and commissioning of weatherproof Junction Boxes (with IP66 Protection) Suitable out door rated IP 55 Loop in loop out Box having a provision of the incoming cable of 4C x 16 sq.mm and 4C x 16 sq.mm & 3C x 1.5/ 2.5 sq.mm outgoing cable complete with glands and mounting arrangements complete as required. \nSize-150mm x 150mm x 60/75 mm depth/ as per requirement. | 47 | 18 | No |
|---|
| 48 | 48 | Supply, Installation, testing and commissioning of weatherproof Junction Boxes (with IP66 Protection) Suitable out door rated IP 55 Loop in loop out Box having a provision of the incoming cable of Cat 6 cable and 2No outgoing Cat 6 cable complete with glands and mounting arrangements complete as required. | 48 | 18 | No |
|---|
| 49 | 49 | Pattern Light (Gobo)\nSupplying, installation, testing and commissioning of architectural Projector luminaire for display of projection of text, logos, patterns and other images by means of a gobo effect & adjustable shutters enable accurate framing of monochrome or colour beams with Built-in (self-ballasted LED module) Long lifetime of 50,000 hours (L80B10 at Ta 25°C),4000K, 55Watt of maximum power consumption & -20oC to +35oC of Operating temperature range. The beam angle – and therefore image size – should be easily on site from 20° to 40°. Degree of ingress protection-IP66,shock rated protection-IK06, Housing: Aluminium casting, ultra-dark grey RAL 10714 painted, RAL colours should be available. ,Universal bracket: galvanized steel laser cutting. Front Cover: air tempered flat glass, thermally hardened, 4 mm thick optical lenses set: clear glass with an anti-reflection coating , CRI 80 ,min 2KV Surge protection & must be expandable to 10 kV with SPD ,External DALI driver possible: 4-poles connector Class II only (-D+/D- with NTC thermal protection) ,Fixation configuration: mast adaptor D60 mm; wall bracket or longer bracket. The fixture must comply to CE, RoHS, compliant with IEC 598 and EN60598 certifications. | 49 | 2 | No |
|---|
| 50 | 50 | Decorative Pole for GOBO Light \nProviding & erecting hot dipped galvanized and PU painted Conical Poles in single section made from 3 mm thick HT plate having lockable weather proof flush door junction box (with Bakellite sheet of 275x75x4mm with 4Nos stud Terminals and two nos of 6 Amp SP MCB and Connector for proper wiring of LED Fittings) complete with foundation bolts of suitable size - 4 nos. 'J' type (EN8 grade), erected in an approved manner on provided foundation. \n9 mtrs. Height, 173 x 75 mm A/F, 275 x 275 x 16mm base plate, 4 nos. X 24 x 750mm long bolt | 50 | 1 | No |
|---|
| 51 | 51 | Decorative Ring Carraige for GOBO Light\nProviding and fixing of PU painted ring carriage dia. not less than 600mm made of 50mm dia. GI pipe Light 'A' class for 75mm A/F top of octagonal pole with required clamps, nut, bolt etc as required. (for mounting Gobo LED flood Lights up to 4 nos) | 51 | 1 | No |
|---|
| 52 | 52 | Basket Hanging Light\nSupplying, installation, testing and commissioning of LED Flood Light IP66 Single Piece Pressure Die Cast Aluminium Housing, High Power LEDs, System Wattage not exceeding 40 Watt (System Lumens > 3200 lumens) with PF >0.9 & voltage range of 140-270VAC, Narrow Beam 20-30-degree and wide Beam- 50-60 deg , Fixture shall operate in a temperature range of 0°C to 35°C, fixture must come with inbuilt surge protection of 2KV & should be extendable to 10KV with the help of external SPD. Min. System Efficacy – 80 lumens per watt, CRI > 70, CCT – 3000 K. Fixture must be BIS certified. | 52 | 18 | No |
|---|
| 53 | 53 | Supply and Fixing of 3Nos. Safety Chain up to 2Mtr. Length each with anchor bolt & nut and other accessories complete as required.,14 SWG galvanized mild steel chain with end rings for hanging fitting as directed. | 53 | 18 | Set |
|---|
| 54 | 54 | Trails Light Set (5Mtr each)\nSupplying, installation, testing and commissioning of flexible strings of large, high-intensity, full-colour, high-brightness RGB LED nodes designed for outdoor Environment, suitable for extraordinary effects and expansive installations without the constraints of fixture size, shape, or space. Each strand consists of individually addressable LED nodes, featuring dynamic integration of power, communication, and control. The flexible form factor accommodates two- and three-dimensional configurations, while high light output affords superior long-distance viewing for architectural accent and perimeter lighting, node count and spacing to match project application requirements. One strings consists minimum 50no's of node with 4inch spacing, total run length of one strings of about 5Mtrs.Strings should be available with lens options—Clear flat/translucent dome/narrow beam lenses as per application usage. Node .Lifetime should be at least 50,000 burning hours. Power consumption-0.5W per node,6lumens per node, Viewing Angle should be 105°-110°,On-Axis Candela per node >2.0,Luminance per node >17,000 cd/m²,IP66. | 54 | 10 | Set |
|---|
| 55 | 55 | Accessories - Supplying, installation, testing and commissioning of DIN rail mountable control module for nodes, Module should be able to supports 400 W of power output which accommodates input and output voltages of 48V DC, KiNET input and output—Data is sent to and from the control module through KiNET, the Ethernet lighting protocol. Electrical: Input Voltage 48 VDC, Power Consumption 3 W at 48 VDC, Power Output 48 VDC, 400 W maximum. Housing Material-Plastic housing, Mounting-DIN rail mountable. Power Supply for nodes designed for use with control module that can accommodate input voltages ranging from 90 VAC - 264 VAC. Electrical: Input Voltage 90 – 264 VAC, 47 – 63 Hz, Power Consumption 2.5 A at 230 VAC, Power Output 48 VDC, 480 W maximum, Connections: Power Input Line-neutral-ground cable, flying leads, Power Output: 2-pin spring terminal, Housing Material -Aluminium enclosure Mounting Slots for DIN rail mounting,IP20. | 55 | 10 | Set |
|---|
| 56 | 56 | Supplying, installation, testing and commissioning and installation of 19mm MS Track for mounting the LED node with mounting arrangement for fixing the track on the existing structure complete as required. | 56 | 50 | Mtr. |
|---|
| 57 | 57 | Post Top Lantern:\nSupplying & fixing Post Top Light Fixtures PDC aluminium, min 2300lumens system output with min. efficacy >=95lumens/watt at System level (Not Chip Level), Life of : 50K Hrs. @ L70B50 Lumen maintenance, CCT of 3000K, CRI >80, PF >0.95, an operating Voltage Range of 120 - 277 V. Driver must have 440V P2P Protection for 8 Hrs. , High Cut off @ 325V (±15V), Auto Restart Feature , Surge Inbuilt : 4 KV , Potted Driver with extendable sure protection up to 10KV with SPD. The fixture design should comply with IS10322, EMC / EMI compliance maintaining driver leakage current as per as per IEC 60598 with BIS certifications, Luminaire Must be having min. IP 66, IK 08 Impact rating. Suitable for operation from 0 to 35Deg C etc. \n40/45W LED (FLORENCE - BGCP 45W LED WW/ Equivalent). | 57 | 118 | No |
|---|
| 58 | 58 | Decorative Pole for Post Top Lantern(Pu Painted Designer Pole)\nProviding and erecting PU Painted decorative pole in different sections made of MS with nipple on top for post top lantern fitting, having lockable weather proof flush door junction box in bottom section (with Bakellite sheet of 275x75x4mm with 4Nos stud Terminals and one no of 6 Amp SP MCB and Connector for proper wiring of LED Fittings) complete with foundation bolts of suitable size - 4 nos. 'J' type (EN8 grade), erected in an approved manner on provided foundation. \n4 mtrs. Height, 140 dia bottom section x 70 dia upper section, 290 dia x 16mm thick base plate, 4 nos. x M14 x 450mm long bolt.\n | 58 | 118 | No |
|---|
| 59 | 59 | Informative Light Box LED (2 nos each box):\nSupplying, installation, testing and commissioning of Medium power architectural RGB LED flood light with housing material of Die-cast aluminium with Tempered glass cover, dark grey powder-coated finish, system wattage not exceeding 75W and system lumen output of not less than 2500 lumens. Fixture shall be available with architectural optics with choice of beam angles of Narrow 8°-12, Medium 15°-20° and Wide 35°-40°.Suitable for DMX/Ethernet. Fixture shall have voltage for Auto-ranging 100V to 240V 50 / 60Hz input. Lifetime should be at least 50,000 burning hours at L70 at 25 degree centigrade with total IP66 protection. fixture operating temperature range -40ºC to 40ºC (-40ºF ~104ºF) & fixture shall equipped with mechanical impact of minimum IK06. fixture must come with inbuilt surge protection of 2KV & should be extendable to 10KV with the help of external SPD. Fixture must be UL / cUL, FCC Class A certified. | 59 | 16 | No |
|---|
| 60 | 60 | Informative Light Box - Providing and fixing of customized decorative outdoor grade informative box made up of MS pipe including mounting bracket for installing the LED luminaire from the top of the box and Cladded with outdoor grade acrylic/ Toughened glass with transparent printed graphic of Height 1.8Mtr,Width of 0.75Mtr with suitable mounting arrangement in ground complete as required as per approved by architect. | 60 | 8 | No |
|---|
| 61 | 61 | Supplying, installation, testing and commissioning of 150mm height pedestal made of PCC having lockable arrangement for mounting the LED Flood luminaire in ground floor with GI cage painted with green colour above the luminaire having a provision cable entry and exit complete as required. | 61 | 8 | No |
|---|
| 62 | 62 | Supply, Installation, testing and commissioning of weatherproof Junction Boxes (with IP66 Protection) Suitable out door rated IP 55 Loop in loop out Box having a provision of the incoming cable of 4C x 16 sq.mm and 4C x 16 sq.mm & 3C x 1.5/ 2.5 sq.mm outgoing cable complete with glands and mounting arrangements complete as required. \nSize- 150mm x 150mm x 60/75 mm depth/ as per requirement. | 62 | 8 | No |
|---|
| 63 | 63 | Supply, Installation, testing and commissioning of weatherproof Junction Boxes (with IP66 Protection) Suitable out door rated IP 55 Loop in loop out Box having a provision of the incoming cable of Cat 6 cable and 2 Nos outgoing Cat 6 cable complete with glands and mounting arrangements complete as required. | 63 | 8 | No |
|---|
| 64 | 64 | Supply of Multi-Protocol Converter, suitable to convert KiNET to DMX or RDM. supports two-way communication between Ethernet and RDM-enabled devices in lighting installation. Housing- Aluminium, Power Consumption -8W.Data Input KiNET/Art-Net via 10/100 Ethernet (RJ45 connector), Data Output Data+, Data- and Common terminal blocks. Mounting- DIN rail mountable, Protection Rating IP20. | 64 | 2 | No |
|---|
| 65 | 65 | Supply, installation, testing and commissioning of IP 65 enclosure made up of MS for mounting the MPC converter of suitable size of 200 x 200 x 100(H) mm complete as required | 65 | 2 | No |
|---|
| 66 | 66 | Supply of DMX Splitter, Booster, Input Power DC 12-24V input, 100-240V, 24VDC plug-in power adaptor included Power Consumption 4.5W max. Housing made of Polycarbonate, Surface mount or DIN-rail mountable, Output Six 3-pin terminal sockets , Connections Two piece compression screw terminals , Protection Rating IP20. | 66 | 2 | No |
|---|
| 67 | 67 | Supply, installation, testing and commissioning of IP 65 enclosure made up of MS for mounting the DMX splitter of suitable size of 300 X300X 150(H) mm complete as required | 67 | 2 | No |
|---|
| 68 | 68 | Supplying, installation, testing and commissioning of Content Program Controller ,Single DMX ports controls more then 300 light addresses, Works as a stand-alone or computer driven controller, Secure Digital (SD) card drive for flexible show storage ,USB 2.0 interface for download-ing shows and configuring from PC,-Flexible, adaptable mounting options ,Should be provided with light show authoring software, Direct line voltage power supports 100—240VAC,Minimum five configurable effects, Using light show authoring software to select from standard five effects, adjust effect settings such as colour, speed, and brightness. | 68 | 2 | No |
|---|
| 69 | 69 | Supplying, installation, testing and commissioning of IP-55 protected Outdoor type floor mounted panel of suitable size for mounting Iplayer3 controller and below items, 240volts, 1 phase, 3 wire 50Hz AC supply system fabricated form CRCA sheet of 2mm thick for frame work and covers and 3mm thick for gland plates with single door, hinged type and support having proper frame and locking arrangement including cleaning and finishing complete with 7 tank process for powder coating in approved shade, GI earth strip of suitable size to be provided in rear portion with 2 nos earth studs, and internal control wiring with 2.5 sq.mm fire retardant insulated copper conductor single core cable, cable gland plates in two half with bottom base providing following incoming and outgoing switch gears etc, Danger notice plate on door. This should have the following 16Amps 2 Pole MCB -1 No 1Ph Surge Protection device Type I- 1No. 1000VA UPS with 15min Backup- 1No. 6A/16A Power Socket - 1 Nos | 69 | 2 | No |
|---|
| 70 | 70 | Supply, installation, testing and commissioning of 8 port ethernet Switch with IP 55 enclosure complete as required. | 70 | 2 | No |
|---|
| 71 | 71 | Decorative Street Light Poles (PU Painted COMBO Poles):\nProviding & erecting 5M Height Decorative without Galvanized Combo Pole Model:-ATRAI along with 1M Single Arm Designer bracket is made of round tube conforming to IS 1161. The pole is given pre-treatment and finished with polyurethane paint giving it a pleasing appearance and antique finish. The pole is mounted on foundation with J Anchor bolts. A door is provided in the base section to mount MCB and cable looping terminals up to 4x16 sq. mm cable.\n | 71 | 49 | No |
|---|
| 72 | 72 | Providing & erecting 6M Height Decorative without Galvanized Combo Pole Model:-ATRAI along with 1M Single Arm Designer bracket is made of round tube conforming to IS 1161. The pole is given pre-treatment and finished with polyurethane paint giving it a pleasing appearance and antique finish. The pole is mounted on foundation with J Anchor bolts. A door is provided in the base section to mount MCB and cable looping terminals up to 4x16 sq. mm cable. | 72 | 1 | No |
|---|
| 73 | 73 | Providing and fixing of decorative single arm Muskedeer bracket made of 40 NB GI Pipe up to 1 Mtr overhang with CAP Pipe 1000mm suitable to mount on Conical pole having top 75mm A/F. | 73 | 1 | No |
|---|
| 74 | 74 | LED Street Light (Side Mounting LED Luminaire)\nSupply and fixing side mounting decorative LED street light (Type:-Celosia SM for ATRAI Pole) made of spun Aluminium powder coated housing with excellent heat dissipation capacity and Optical grade injection moulded polycarbonate clear Diffuser.High lumen efficacy >90 Lm/W, Correlated Color Temperature shall be 3000K ± 500K, Color Rendering Index shall be =70. Lumen output- L70@ 50000 burning hrs, High bright discreet LED shall be used in Luminaries with Type-II Optics. Power Factor shall be > 0.95%, THD=10%, Built-in Surge protection- 4KV, External Surge Protection- 10KV, Ingress protection (IP)-65, Impact Resistance (IK)-05, Driver Type-Potted Driver and the Efficiency shall be =85%. Weatherproof gaskets provided for LEDs and control gear compartments to ensure IP66 protection. LEDs shall be provided with non-yellowing modular secondary lens optics with high impact resistance (IK 07), The driver shall be used is specially designed to have built-in surge voltage, open/short circuit protections. Top opening driver compartment required for easy maintenance. OperatingTemperature Range -10°C to 50°C. Input Voltage-150 to 270V AC, Input Frequency-50Hz, Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab.\n60W Luminaries Type:-Celosia SM for ATRAI Pole. | 74 | 49 | No |
|---|
| 75 | 75 | Metering & Connection Charges:\nSITC of metering equipment including application fee, security deposit, consumption demand charges & other charges etc for sanction/ release of electrical connection from concerned power supply company/ DISCOM. | 75 | 1 | LS |
|---|
| 76 | 76 | Cost for Environmental Management Plan (EMP) includes deployment of one no. of EHS supervisor, Surface water testing, and Drinking water testing, capacity building for implementation of EMP. | 76 | 1 | Lot |
|---|