Chemicals and Fertilizers Boards / Undertakings / PSU Closing in 0 days TDR #26335513

Notice Inviting Tender For Supply Of Ph Transmitter , Orp Tranmitter , Conductivity Tranmitter , Turbidity Analyser Notice Inviting Tender For Supply Of Ph Transmitter , Orp Tranmitter , Conductivity Tranmitter , Turbidity Analyser

Issued by Boards / Undertakings / PSU · Rashtriya Chemicals and Fertilizers Ltd. MUMBAI, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
12 Jan 2021
0 days left
EMD
20000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rashtriya Chemicals and Fertilizers Ltd. MUMBAI → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Notice Inviting Tender For Supply Of Ph Transmitter , Orp Tranmitter , Conductivity Tranmitter , Turbidity Analyser Notice Inviting Tender For Supply Of Ph Transmitter , Orp Tranmitter , Conductivity Tranmitter , Turbidity Analyser

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 01-Jan-2021 Due date of the tender extended up to 09.01.2021 Date 09-Jan-2021
2 08-Jan-2021 Due date of the tender extended up to 12.01.2021 Date 12-Jan-2021

BOQ

Name of Work: SUPPLY OF PH TRANSMITTER, ORP TRANMITTER, CONDUCTIVITY TRANMITTER, TURBIDITY ANALYSER
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11MICROPROCESSOR BASED ON LINE pH TRANSMITTER WITH SENSOR FOR EFFLUENT SERVICE AS PER FOLLOWING TECHNICAL SPECIFICATIONS:\n1] MEASURING RANGE : 0 - 14pH, SELECTABLE;\n2] POWER SUPPLY 12 V- 36 V DC, 2 WIRE;\n3] OUTPUTS : 4 - 20 mA, HART\n4] OUTPUT LOAD : 600 OHMS AT 24 V DC;\n5] DISPLAY: LCD;\n6] pH ACCURACY : +/- 0.01 pH;\n7] OUTPUT CURRENT ACCURACY : +/- 0.3 % OF FS;\n8] pH SENSOR: COMBINED pH GLASS ELECTRODE 0-14 pH, SINGLE DIAPHRAGM SUITABLE FOR PRESSURE UP TO 6 KG/CM2, MEASURING CYCLE T90 < 15 SECONDS;\n9] TEMPERATURE SENSOR: PT-100 OR THERMISTER SHALL BE SUPPLIED FOR TEMPERATURE RANGE 0 -100 DEG CENTIGRADE;\n10] LOCAL KEYPAD: REQUIRED FOR PROGRAMMING, CALIBRATION;\n11] DATA ENTRY: INTO EEPROM, NON-VOLATILE MEMORY;\n12] TEMPERATURE COMPENSATION : AUTOMATIC AS WELL AS MANUAL REQUIRED;\n13] ENCLOSURE: EPOXY COATED DIE-CAST ALUMINIUM, INGRESS PROTECTION: IP65;\n14] CALIBRATION : ONE POINT / TWO POINT SELECTABLE, pH SENSOR SLOPE : 70% TO 110%, SELF DIAGNOSTICS: YES;\n15] FLOW THROUGH CHAMBER WITH 1/2 INCH NPT (F) INPUT AND OUTPUT MOC PP OR SS: REQUIRED;\n16] SERVICE: FERTILIZER EFFLUENT DISCHARGE;\n17]CERTIFICATION: TUV OR US EPA OR MCERT APPROVED ANALYSER ONLY CERTIFICATE SHALL BE ENCLOSED;\n18] CABLE GLANDS: 1/2 INCH NPT MALE IN SS304 REQUIRED;\n19] TRANSMITTER MOUNTING: 2 INCH PIPE MOUNTING HARDWARE IN SS IS TO BE SUPPLIED;\n20]SENSOR CABLE: 5 METERS;\n21]BUFFER SOLUTION: 4.01, 7.00 AND 9.20 OF 500 ML EACH SHALL BE SUPPLIED;\n22] DOCUMENTATION: TWO SETS OF MAINTENANCE MANUALS WITH CALIBRATION AND MAINTENACE PROCEDURES AND DETAILED PART NUMBERS IN HARD COPY NEED TO BE SUPPLIED.\nItem- 3000780175NOS
22ORP TRANSMITTER WITH SENSOR\nSERVICE: WATER\nPRESSURE:2 KG/CM2 MAX\nTEMPERATURE: NORMAL 40 DEG. C, MIN 25 AND MAX. 50 DEG. C\nSENSOR TYPE: COMBINED GLASS ELECTRODE\nSENSOR ELEMENT:PT WIRE\nSENSOR RANGE:-1200MVDC TO +1200MVDC ( ADJUSTABLE RANGE )\nTEMPERATURE SENSO: PT100 RTD\nSENSOR CABLE: 10 FEET MINIMUM SHIELDED\nSENSOR MOUNTING: SENSOR CHAMBER WITH 1/2\" NPT FEMALE INLET /OUTLET\nCONNECTION SS FLOW THROUGH CHAMBER SHALL BE PROVIDED\nTRANSMETER ELECTRONICS: MICROPROCESSOR BASED DIGITAL\nPOWER SUPPLY : 24V DC (TWO WIRE SYSTEM)\nOUTPUT :4 - 20 MA DC TWO WIRE AT 500 OHMS.\nMEASUREMENT RANGE: -1200MVDC TO +1200MVDC (ADJUSTABLE RANGE)\nTEMPERATURE RANGE.( SENSOR):0 - 100 DEG C\nTEMPERATURE COMPENSATION: AUTOMATIC 0-100 DEG C AND MANUAL IN VARIOUS\nSTEP\nINPUT IMPEDANCE:> 10,00,000 M OHMS\nDISPLAY: LCD\nCALIBRATION POINTS: 2 POINT CALIBRATION THROUGH KEY PAD\nCOMBINED ACCURACY: +/- 0.5 % OF FSD OR BETTER\nENCLOSURE PROTECTION: IP65EPOXY COATED CAST ALUMINIUM / NON CORROSIVE ABS PLASTIC STANDARD SOLUTIONS/ CALIBRATION KIT:TO BE PROVIDED BY THE PARTY FOR 2\nPOINT CALIBRATION QTY: 500ML EACH OR EQUIVALENT\nCABLE GLAND : SUITABLE CABLE GLANDS OF REQUISITE QTY SHALL BE PROVIDED. MOUNTING (TRANSMITTER): 2\"PIPE MOUNTING WITH REQUIRED ACCESSORIES\nItem- 3000780432NOS
33TECHNICAL SPECIFICATIONS FOR MICROPROCESSOR BASED ON LINE TWO WIRE CONDUCTIVITY TRANSMITTER: \n1] MEASURING RANGE: 0 - 500 µS/ CM, SELECTABLE ANYWHERE BETWEEN 0 AND 500. \n2] SUPPLY: A] POWER SUPPLY 12 V-\n36 V DC B]LOAD : 600 OHMS AT 24 V DC C] TYPE 2 WIRE \n3] OUTPUTS : A] 4 -20 mA, HART B] DISPLAY: 2 LINE, 10 CHARACTER 4] ACCURACY : A] DISPLAY CONDUCTIVITY : +/- 0.5% FS B] OUTPUT CURRENT : +/- 0.1 mA \n5] INPUTS : A] CONDUCTIVITY SENSOR B] TEMPERATURE SENSOR: PT-100 C] LOCAL KEYPAD FOR PROGRAMMING, CALIBRATION D] DATA ENTRY INTO EEPROM, NON-VOLATILE MEMORY\n6] AUTOMATIC AS WELL AS MANUAL TEMPE RATURE COMPENSATION, MEASURING CYCLE< 5 SECONDS \n7] ENCLOSURE: EPOXY COATED DIE-CAST ALUMINIUM, INGRESS\nPROTECTION: IP66 \n8] SELF DIAGNOSTICS: YES. \n9] SAMPLE POT: REQUIRED \n10] SERVICE: MAIN STEAM / CBD / POLISH WATER / DM WATER / SEWAGE WATERItem- 3000810316NOS
44DESCRIPTION: CONDUCTIVITY TRANSMITTER,\nSERVICE: FILTERED WATER. POWER SUPPLY: 24 VDC (TWO WIRE TRANSMITTER).\nMEASURING PARAMETER: CONDUCTIVITY.\nRANGE: 0 - 2000 MICRO SIEMENS / CM.\nLOCAL DISPLAY DIGITAL IN ENGG. UNIT.\nOUT PUT: ISOLATED 4-20 MA INTO 575 OHMS AT 24VDC.\nMOUNTING: 2 PIPE.\nACCURACY: 1% OF FULL SCALE. ENCLOSURE: NEMA 4X. SENSOR:\nMATERIAL OF CONSTRUCTION: TEFZAL, GLASS, CERAMIC AND VITON.\nFLOW THROUGH CHAMBER, CHAMBER SHOULD BE SUPPLY BY VENDOR. PROCESS CONNECTION: ½ INCH (F) NPT\nBOTH FRONT AND REAR THREADS.\nWETTED MATERIAL: ELECTRODE : 316 SS.\nINSULATORS : TEFZEL, AND VITON. TEMPERATURE COMPENSATION: 0 - 1000C.\nINTERCONNECTING CABLE: 12 FOOT SHIELDED, PROVIDED WITH SPADE\nMAX PRESSURE : 70 PSIG\nItem- 3001009532NOS
55ONLINE TURBIDITY ANALYSER\nGENERAL:\nSERVICE: TREATED WATER OF STP\nINSTRUMENT RANGE: 0 TO 10.00 NTU /FTU\nFLOW: 0.2 TO 1 L/MIN\nSAMPLE PRESSURE: 2 KG /CM2\nMEASUREMENT TECHNIQUE: 90 DEG SCATTERED LIGHT METHOD\nSENSOR:\nCLEANING OF WINDOW: AUTOMATIC SWING WIPER CLEANING SYSTEM TEMPERATURE RATING: 0 # 50 DEG C\nCABLE: 10 METER CABLE.\nMATERIAL / BODY: SS316L WITH SCRATCH PROOF SAPPHIRE / QUARTZ GLASS WINDOW\nPROTECTION CLASS: IP68\nCLEANING INTERVAL :30 MIN.(SELECTABLE)\nMOUNTING OF SENSOR: TWO TYPES OF SENSOR MOUNTING SHALL BE PROVIDED AS FOLLOWS 1) FLOW THROUGH CHAMBER. MOC: SS 316, PROCESS CONNECTION: ½#NPT (F) FOR INPUT AND OUTPUT. \n2) DIP TYPE HOLDER OF LENGTH 1METER FOR DIRECT INSTALLATION IN OPEN TANK FROM TOP TRANSMITTER:\nTYPE: MICROPROCESSOR BASED\nACCURACY: +/- 5% OF READING\nRESPONSE TIME: LESS THAN 5 SEC\nDISPLAY RESOLUTION: 0.01 NTU /FTU\nDISPLAY TYPE: LCD\nMOUNTING 2 INCH PIPE MOUNTING TYPE. ALL REQUIRED MOUNTING ACCESSARIES SHALL BE INCLUDED IN SUPPLY\nAMBIENT TEMPERATURE: 10 TO 50 DEG CEN\nHUMIDITY: 95% RH\nENCLOSURE MATERIAL: POLYCARBONATE / AL ALLOY\nENCLOSURE PROTECTION: IP65, NEMA 4X\nOUTPUTS ANALOG OUTPUT: 4-20 MA, 300 & LOAD\nPOWER SUPPLY: 110 V AC, 50 HZ OR UNIVERSAL\nCALIBRATION SOLUTION/ VARIFICATION KIT: FIXED VALUE SPAN CALIBRATION SOLUTION 500 ML.OR EQUIVALENT VARIFICATION KIT\nItem- 3001263633NOS
66TECHNICAL SPECIFICATIONS FOR MICROPROCESSOR BASED ON LINE TWO WIRE pH TRANSMITTER: \n1] MEASURING RANGE : 0 - 14pH, SELECTABLE \n2] SUPPLY : A] POWER SUPPLY 12 V- 36 V DC B]LOAD : 600 OHMS AT 24 V DC C] TYPE 2 WIRE\n3] OUTPUTS : A] 4 - 20 mA, HART B] DISPLAY: 2 LINE, 10 CHARACTER 4] ACCURACY : A] DISPLAY pH : +/- 0.01 pH B] OUTPUT CURRENT : +/- 0.1 mA \n5] INPUTS : A] COMBINED pH SENSOR B] TEMPERATURE SENSOR: PT-100 C] LOCAL KEYPAD FOR PROGRAMMING, CALIBRATION D] DATA ENTRY INTO EEPROM, NON-VOLATILE MEMORY \n6] AUTOMATIC AS WELL AS MANUAL TEMPE RATURE\nCOMPENSATION, MEASURING CYCLE< 5 SECONDS \n7] ENCLOSURE: EPOXY COATED DIE-CAST ALUMINIUM, INGRESS PROTECTION: IP66 \n8] CALIBRATION : ONE POINT/ TWO POINT SELECTABLE, pH SENSOR SLOPE : 70% TO 110%. SELF DIAGNOSTICS: YES. \n9] SAMPLE POT: REQUIRED 10] SERVICE: MAIN STEAM / CBD / POLISH WATER / DM WATER / SEWAGE WATER\nItem- 3000810346NOS

AI Tender Summary

OUR REF NO 26335513
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 12-01-2021
Authority
Authority Name Rashtriya Chemicals And Fertilizers Limited
Work Description Notice Inviting Tender For Supply Of Ph Transmitter , Orp Tranmitter , Conductivity Tranmitter , Turbidity Analyser Notice Inviting Tender For Supply Of Ph Transmitter , Orp Tranmitter , Conductivity Tranmitter , Turbidity Analyser
Basic Detail
Tender No E203201203S
Bidding Type Tender
Location
City Rashtriya Chemicals and Fertilizers Ltd. MUMBAI
State Maharashtra
Key Dates
Publish Date 08 Jan 2021
Submission Date 12 Jan 2021
Open Date 12 Jan 2021
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 20000
Exemption Not Available
Document List
86AB35A3-934A-476A-B180-1EAB30722B22.html
Tendernotice_1.pdf
BOQ_635309.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 08, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 09, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 12, 2021
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 12, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 12, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

86AB35A3-934A-476A-B180-1EAB30722B22.html

pdf

Tendernotice_1.pdf

xls

BOQ_635309.xls

TenderDetail
Loading tenders