| 1 | 1 | Labour for laying of cable through HDPE pipe ( 50 mm OD ) in plain cement concrete road including braking of cement concrete road & Filling of plain cement concrete mix of 1:1.5:3 ( with 12 mm jelly ) INCLUDING CARTING OF CABLE & HDPE PIPE (TRENCH SIZE 100mm BREADTH X 150mm DEPTH ) | | 150 | Mtrs |
|---|
| 2 | 2 | Cost of Erection of KIOSK pillar box | | 3 | Nos |
|---|
| 3 | 3 | Cost of KIOSK pillar box | | 3 | Nos |
|---|
| 4 | 4 | Supplying & laying/ Fixing of 3 x 1.0Sq.mm PVC insulated, PVC sheathed copper conductor flexible cable of 1.1 KV grade of following sizes in the following manners complete i/c connection, testing with all accessories etc. as required . | | 50 | Mtrs |
|---|
| 5 | 5 | I.SI.MARKED 3 1/2X25 SQ.MM CABLE | | 58 | Mtrs |
|---|
| 6 | 6 | Supplying & laying/ Fixing of 3 x 2.5Sq.mm PVC insulated, PVC sheathed copper conductor flexible cable of 1.1 KV grade of following sizes in the following manners complete i/c connection, testing with all accessories etc. as required . | | 550 | Mtrs |
|---|
| 7 | 7 | Supplying and laying of 3 x 2.5 sqmm PVC insulated PVC sheathed copper conductor flexible cable in a insulated pipe | | 800 | Mtrs |
|---|
| 8 | 8 | Supply of cable gland suitable to 3 core 2.5 sq.m | | 160 | Each |
|---|
| 9 | 9 | Supply, Installation, Testing and commissioning of classic LED post top with housing material of Die-cast aluminium, UV protected semi transparent diffuser, system wattage not exceeding 36W and system lumen output of not less than 4000 lumens, with CRI>70 and the SDCM should be less than 5. The fixture optics shall be polycarbonate diffuser and the CCT shall be 3000K.Fixture dimension (Dia X Height) shall be not larger than 450mm dia and 210mm and weight not more than 5.0kgs. The driver should have the inbuilt of 4Kv surge protection, auto restart and High cut off ( >325V) and the operatiing voltage range shall be 120-277V. THD shall be less than 10% at full load. Lifetime should be at least 50,000 burning hours at L70 with total IP66 protection. Fixture shall equipped with mechanical impact of minimum IK10. | | 60 | Each |
|---|
| 10 | 10 | Ethernet keypad module for the dmx controller for selecting multiple scenes | | 1 | Each |
|---|
| 11 | 11 | Supplying & laying/ Fixing of 4 x 16 sq.mm (UG cable) PVC insulated, PVC sheathed copper conductor flexible cable of 1.1 KV grade of following sizes in the following manners complete i/c connection, testing with all accessories etc. as required . | | 100 | Mtrs |
|---|
| 12 | 12 | Supplying and laying/ Fixing of Armoured UTP 4 pair CAT 6 LAN cable on surface complete i/c connection, testing etc. as required | | 550 | Mtrs |
|---|
| 13 | 13 | Supply of 1kVA UPS power device with minimum 30 - 120min backup time with all necessary accessories | | 1 | Each |
|---|
| 14 | 14 | Earthing as per greater chennai corporation standard with an earth electrode of less than 2 Mtr. Class 'B' GI pipe of dia not less than 32mm complete with necessary masonry work. | | 2 | Each |
|---|
| 15 | 15 | Supply and Installation of POE Ethernet switch with 8 PoE ports. It shall be compact and able to provides four PoE ports for use with PoE-complaint controllers. It shall be easily connect PoE-enabled devices using standard CAT 5e or better Ethernet cables. The operating voltage range shall be 100 - 240V AC and the maximum power consumption shall be 65W. Operating temperature shall be 0 to 40° C and the IP rating shall be IP20 | | 3 | Each |
|---|
| 16 | 16 | Supply of Weatherproof cabinets/ junction box with IP 65, IK 09 protection with Class II Door for providing connectivity between luminaries and the supply line | | 170 | Each |
|---|
| 17 | 17 | Fabrication, supplying, installation and commissioning of outdoor double door cubical feeder pillar of suitable size with locking arrangement in front & back with rain cap cover suitable for 3 phase, 4 wire 415 volt 50Hz dust and vermin proof made with CRCA sheet duly compartmentalized. It should have spacing to install the LMS, POE Switch and other lighting accessories. It should supplied with minimum 10 no's of power point/ socket. It should have the proper air ventilation fan and system. The panel shall be complete in all respect with latest upto date system. | | 1 | Each |
|---|
| 18 | 18 | I.SI.MARKED 2 X 16 SQ.MM CABLE | | 1440 | Mtr |
|---|
| 19 | 19 | Supply of outdoor rated three phase 15kVA High Grade Voltage Stabiliser for the installation with features: Low & High Voltage Cut-off Protection Range from 320V-440V Easy Mounting Cabinet Design-Elegant and easy to install with integrated circuit technology for protection on Thermal Overload Protection | | 1 | Each |
|---|
| 20 | 20 | IP65 rated enclosure box for accomadating the Control module and driver with all necessary accessories | | 14 | Each |
|---|
| 21 | 21 | Supply, Installation of mesh structure for the mid power architectural RGB LED flood light luminaries to avoid the unauthorized access. | | 40 | Each |
|---|
| 22 | 22 | ROAD CUTTING BY MECHANIZED TOOL INCLUDING CARTING & DRAWAL OF CABLE & HDPE DWC PIPE | | 100 | Mtr |
|---|
| 23 | 23 | HDPE PLAIN PIPE OF SIZE 50MMX2.8MM THICK WITH SILICON COATING ( ALL COLOUR EXCEPT BLACK ) | | 1150 | Mtr |
|---|
| 24 | 24 | Supply of white/ black color all weather proof 4 wired 50ft jumper Cable for use with Power/Data Supplies and the nodes | | 8 | Each |
|---|
| 25 | 25 | Supply of white/ black color all weather proof 4 wired 100ft jumper Cable for use with Power/Data Supplies and the nodes | | 2 | Each |
|---|
| 26 | 26 | Supply of white/ black color all weather proof 3 wired 25ft jumper Cable for use with Power/Data Supplies and the nodes | | 24 | Each |
|---|
| 27 | 27 | Supply, Installation, Testing and Commissioning of 4 wire IP66 outdoor rated data supply for the RGB LED hight intensity node. The power consumption shall be less than 4W. The module dimension(Height x Width x Depth) shall be not larger than 40 x 90 x 210mm and weight not more than 1.0kgs. The module shall takes 24V DC power and combines it with either KiNet or DMX512 control data, to two separate, fuse-protected, outputs ports with 4 wire single ended output. It shall be with snap-lock panel mount connectors to ensure a fast and reliable connection. | | 5 | Each |
|---|
| 28 | 28 | SUPPLY OF ONE NO OF 2 Mtr X 60.3 MM OD X 3.65mm THICK STREET LAMP POST (FOR POST TOP LANTERN FITTING, 2 CORE SMC FUSE BOX WITH Hot dip zinc galvanising) | | 60 | Nos |
|---|
| 29 | 29 | Supply of black color nodes mount for the the LED nodes | | 34 | Each |
|---|
| 30 | 30 | Supply, Installation, Testing and Commissioning of 3 wire IP66 outdoor rated data supply for the RGB LED hight intensity node. The power consumption shall be less than 4W. The module dimension(Height x Width x Depth) shall be not larger than 40 x 90 x 210mm and weight not more than 1.0kgs. The module shall takes 24V DC power and combines it with either KiNet or DMX512 control data, to two separate, fuse-protected, outputs ports with 3 wire single ended output. It shall be with snap-lock panel mount connectors to ensure a fast and reliable connection. | | 12 | Each |
|---|
| 31 | 31 | FIXING OF ABOVE 63 AMP / 3Phase Microprocessor based digital AUTOMATIC STREET LIGHTING ON / OFF CONTROLLING TIMER UNITS as per departmental specification | | 3 | Each |
|---|
| 32 | 32 | Cost of Erection & materials required for 2 mtr Garden lamp pole ( Post of Lantern Type) ( WITH Hot dip zinc galvanising of anchor bolts & Flats) (NORMAL SOIL)(Material ratio - 1:1.5:3) | | 60 | Nos |
|---|
| 33 | 33 | SUPPLY OF 63 AMP / 3Phase Microprocessor based digital AUTOMATIC STREET LIGHTING ON / OFF CONTROLLING TIMER UNITS as per departmental specification | | 3 | Each |
|---|
| 34 | 34 | Supply, Installation, Testing and Commissioning of exterior RGB LED high intensity node with housing material of Black polycarbonate, system wattage not exceeding 1W per node and system lumen output of not less than 10 lumens with Clear UV-protected polycarbonate. Fixture lens shall be a Clear UV-protected polycarbonate. Fixture beam angles should be greater than 160°. Individual nodes should be programmable using 8 bit or 16 bit control with DMX512/ Ethernet controller protocol as per the lighting sequence required for desired theme creation. Fixture dimension(Height x Width x Depth) shall be not larger than 35 x 35 x 30 mm and weight not more than 2kg for 50 nodes. Fixture shall operate in a temperature range of -40°C to 50°C. Lifetime should be at least 50,000 burning hours at L70, IP66 protection. | | 34 | Each |
|---|
| 35 | 35 | Supply, Installation, Testing and Commissioning of Content Program Controller specifically designed for author, configure, and control intricate LED light shows in multiple zones, Input Power- 100 to 240 VAC, auto-ranging, 50/60 Hz, Power Consumption 200 W maximum, Minimum supported LED Nodes 10,000, Network Data- Ethernet protocol, Max Dimensions (Height x Width x Depth) 250 x 320 x 80 mm, Max. Weight 5.0kg, Housing- Aluminium enclosure, Connector/Cable (2) RJ45 ports, shielded Cat. 5e or better data cable. | | 1 | Each |
|---|
| 36 | 36 | Ethernet Keypad is a compact keypad that triggers the above controller. Operating temperature shall be 5 to 50 °C. Keypad light shows at the touch of a button. IP rating shall be IP20. The power consumption of the device shall be maximum 3W along with the module. | | 1 | Each |
|---|
| 37 | 37 | Supply, Installation, Testing and Commissioning of Multi-Protocol Converter that performs a range of lighting protocol conversions, including KiNET, the Ethernet lighting protocol to DMX512, DMX512 to KiNET, and RS232 to KiNET. KiNET to DMX512 conversion to use DMX-based power / data supplies with any KiNET-based device, IP40,Operating Temperature -10° to 40°C .Max. Dimensions (Height x Width x Depth) 40 x 120 x 90 mm.Max.Weight 0.20 kg. | | 2 | Each |
|---|
| 38 | 38 | Supply, Installation, Testing and Commissioning of DMX booster/ splitter that takes the incoming DMX/RDM signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6 X 32. The output terminals are electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. IP20,Operating Temperature -10° to 35°C .Max. Dimensions (Height x Width x Depth) 40 x 120 x 90 mm.Max.Weight 0.250 kg. | | 2 | Each |
|---|
| 39 | 39 | Supply of mounting track for the IP66 rated flexible linear light. It shall have the dimension (Length x Width x Depth) shall be not larger than 1000 x 15 x 10mm. | | 25 | Each |
|---|
| 40 | 40 | Supply, Installation, Testing and Commissioning of IP66 rated driver with 24V DC output and the input voltage shall be 100 to 277V. The output DC voltage not less than 100W. The IP rating for the driver shall be greater than IP66. It should comply UL, CE, PSE certification. | | 42 | Each |
|---|
| 41 | 41 | Supply, Installation, Testing and Commissioning of Medium power architectural RGB LED flood light with housing material of Die-cast aluminium, dark grey powder-coated finish, system wattage not exceeding 75W and system lumen output of not less than 2300 lumens with CRI=80.Fixture shall be available with architectural optics with choice of beam angles of Narrow 8°-12, Medium 15°-20° and Wide 35°-40°.Suitable for DMX/Ethernet. Fixture dimension (Height x Width x Depth) shall be not larger than 280 x 360 x 100mm and weight not more than 6.0kgs. Fixture shall operate in a temperature range of 0°C to 40°C. Fixture shall have input voltage for 220 – 240 VAC. Lifetime should be at least 50,000 burning hours at L70 at 25 degree centigrade with total IP66 protection. Fixture shall equipped with mechanical impact of minimum IK06. | | 40 | Each |
|---|
| 42 | 42 | Supply, installation, testing and commissioning of IP 66 LED flexible linear light fixture operating on 24VDC supply. The fixture power consumption of 8W using mono color LEDs. Fixture shall have 3000k CCT with CRI > 80. Beam angle of 120 degrees. The luminaire shall be able to deliver 10 lux / 1 fc at 8 ft from luminaire with a beam width of > 28 ft in both horizontal and vertical plane. The fixture should be with extruded silicone housing & Frosted silicone lens. The fixture operating temperature shall be -40 to 50 °C. The lumen output of the product with lens should be >750lm for 1mtr length. The luminaire shall be with system efficacy of > 99 lm / W (All Channels Full On). The fixture weight should be less than 1Kg and dimensions should be less than 15 x 1000x 10 mm. Fixtures should supplied with driver and other necessary accessories. | | 250 | Each |
|---|
| 43 | 43 | Cost of supply of Double wall corregated duct 120/103.5mm - Orange or Blue colour ( to be used instead of HUME PIPE) | | 100 | Mtr |
|---|
| 44 | 44 | LAYING OF CABLE ALONG ROAD / STREET THROUGH 50mm O D, H.D.P.E. PIPE (TRENCH SIZE 45CM WIDTH X 75 CM DEPTH) | | 1000 | Mtr |
|---|
| 45 | 45 | Installation, aiming, testing and commissioning of 20 mtr HIGH MAST as per specification | | 1 | Each |
|---|
| 46 | 46 | supply of 20 mtr HIGH MAST as per specification | | 1 | Each |
|---|