Supply , Installation , Testing And Commissioning Of 8 . 5 Tr And 11 Tr Ductable Ac As Per Tender Specification At Digboi Refinery, IOCL (AOD) DIGBOI-Assam

Indian Oil Corporation Limited-IOCL has published Supply , Installation , Testing And Commissioning Of 8 . 5 Tr And 11 Tr Ductable Ac As Per Tender Specification At Digboi Refinery. Submission Date for this Tender is 26-12-2020. Coats and Jackets Tenders in IOCL (AOD) DIGBOI Assam. Bidders can get complete Tender details and download the document.




Tender Notice

26299481
Supply , Installation , Testing And Commissioning Of 8 . 5 Tr And 11 Tr Ductable Ac As Per Tender Specification At Digboi Refinery
Open Tender
Indian
Assam
IOCL (AOD) DIGBOI
26-12-2020

Tender Details

Supply , Installation , Testing And Commissioning Of 8 . 5 Tr And 11 Tr Ductable Ac As Per Tender Specification At Digboi Refinery , List Of Item ( S ) / Work ( S ) As Per Tender Documents , Design , Engineering , Manufacturing And Procurement Of Materials And Bought Out Components , Assembly , Supply , Erection , Testing , Commissioning , Performance Guarantee Testing At Site Of 8 . 5 Tr , 01 No . Air Cooled Ductable Package Air Conditioners For Gymnasium Hall Of Tt Cum Gym Building Near Digboi Club As Per Technical Specifications & Scope Of Work . , Design , Engineering , Manufacturing And Procurement Of Materials And Bought Out Components , Assembly , Supply , Erection , Testing , Commissioning , Performance Guarantee Testing At Site Of 11 Tr , 01 No . Air Cooled Ductable Package Air Conditioners For Tt Hall Of New Tt Cum Gym Building Near Digboi Club As Per Technical Specifications & Scope Of Work , Installation Testing And Commissioning Of Ductable Split Ac Complete With All Material And Labour To Ensure Completion Of The Job In Totality As Per Directions Of Eic . The Ac Operation Must Be Through A Small Wall Mounted Control Panel Completely Flushed Inside Wall With Concealed Wiring . A Wireless Remote Control To Be Provided With Each System For Remote Operation , Duct FabricationI ) 22 Gauge , Duct FabricationIi ) 24 Gauge , Acoustic InsulationSupplying And Fixing Acoustic Insulation On The Surface Of Supply Air Duct , Laminated With 12 Mm Thick Fibre Glass Of Density 48 Kg/Cum And Covered With 30 Swg Aluminium Perforated Sheet . , Thermal InsulationSupplying And Fixing Thermal Insulation On The Outer Surface Of Supply Air Duct With 25 Mm Thick Fibre Glass Of Density 24 Kg/Cum With Cold Bituminous Adhesive And Fibre Glass Should Be Aluminium Foil Pasted , Secured By Pvc Strap And Anchor Clip . , Refrigerant PipingI ) For Split AcSupply And Installation Of Refrigerant Piping Suitable For Above Split A . C . Units Including Nitryle Rubber Insullation , Refrigerant PipingIi ) For Ductable AcSupplying And Installation Of Copper Refrigerant Pipe As Suitable Size ( For Set Of Suction And Liquid Line ) With Armaflex Insulation For Ductable Split Air Conditioner . , GrillsSupply And Installation Aluminium Powder Coated Grills For Supply / Return Air Including All Accessories Complete , Drain PipingI ) 25 Mm , Drain PipingIi ) 32 Mm , Canvass Connection , Odu Structure Wall Split AcSupplying And Installation Of M . S . Fabricated Odu Structure Installation With All Accessories For Wall Split Ac , Odu Structure Ductable AcSupplying And Installation Of M . S . Fabricated Odu Structure Installation With All Accessories For Ductable Ac , Power/ Control Cabling 3C X 2 . 5 Sq . Mm . Supply And Installation Of Electrical Power/ Control Cabling Of Suitable Size Between Indoor Units And Indoor Units , Dismantling Alum . / Gypsum Ceilings Etc . Dismantling Aluminum/Gypsum Partitions , Doors , Windows , FixedGlazing And False Ceiling Including Disposal Of Unserviceable SurplusMaterials And Stacking Of Serviceable Material With In 50 MetersLead As Directed By Engineer-In-Charge , 12 . 5 Mm Thick Tapered Edge Gypsum Moisture Resistant Board , Two Or More Coats Applied On Walls @ 1 . 25 Ltr/10 Sqm . Over And Including One Coat Of Special Primer Applied @ 0 . 75 Ltr / 10 Sqm . , Providing And Applying Plaster Of Paris Putty Of 2Mm Thickness OverPlastered Surfaces To Prepare The Surface Even And Smooth Complete , Hand RailsProviding And Fixing Hand Rail Of Approved Size By Welding Etc . To Steel Ladder Railing , BalconyRailing & Stair Case Railing & Stair Case Railing Including Applying A Priming Coat Of Approved Steel Primer . M . S . Tube , With Cement Issued At Issue Rates From Owners Stores , Including Transportation From Stores To Work Site And Returning All Excess/ Unused Cement To Owner Storeage Point After Completion Of Work- Washed Stone Aggregate 20 Mm Nominal Size , Area Indexation @ 26 . 73%

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 8.5 TR AND 11 TR DUCTABLE AC AS PER TENDER SPECIFICATION AT DIGBOI REFINERY
Sl. No. Item Description Item Code / Make Quantity Units
1 1 List of item(s) / work(s) as per tender documents
2 10 Design, Engineering, Manufacturing And Procurement Of Materials And Bought Out Components, Assembly, Supply, Erection, Testing, Commissioning, Performance Guarantee Testing at Site of 8.5 TR, 01 No. Air Cooled Ductable Package Air Conditioners For gymnasium hall of TT cum Gym building near Digboi Club As per Technical Specifications & Scope Of Work. Item10 1 EA
3 20 Design, Engineering, Manufacturing And Procurement Of Materials And Bought Out Components, Assembly, Supply, Erection, Testing, Commissioning, Performance Guarantee Testing at Site of 11 TR, 01 No. Air Cooled Ductable Package Air Conditioners For TT hall of new TT cum gym building near Digboi club As per Technical Specifications & Scope Of Work Item20 1 EA
4 30 Installation testing and commissioning of ductable split AC complete with all material and labour to ensure completion of the job in totality as per directions of EIC. The AC operation must be through a small wall mounted control panel completely flushed inside wall with concealed wiring. A wireless remote control to be provided with each system for remote operation Item30 2 EA
5 40 DUCT FABRICATION\ni) 22 Gauge Item40 20 M2
6 50 DUCT FABRICATION\nii) 24 Gauge Item50 70 M2
7 60 ACOUSTIC INSULATION\nSupplying and fixing acoustic insulation on the surface of supply air duct, laminated with 12 mm thick fibre glass of density 48 kg/cum and covered with 30 SWG aluminium perforated sheet. Item60 20 M2
8 70 THERMAL INSULATION\nSupplying and fixing thermal insulation on the outer surface of supply air duct with 25 mm thick fibre glass of density 24 kg/cum with cold bituminous adhesive and fibre glass should be Aluminium foil pasted, secured by PVC strap and anchor clip. Item70 70 M2
9 80 REFRIGERANT PIPING\ni) For split AC\nSupply and installation of refrigerant piping suitable for Above split A.C. Units including Nitryle Rubber Insullation Item80 10 M
10 90 REFRIGERANT PIPING\nii) For Ductable AC\nSupplying and installation of Copper Refrigerant pipe as suitable size (for set of suction and liquid line) with Armaflex insulation for Ductable Split Air Conditioner. Item90 15 M
11 100 Grills\nSupply and installation Aluminium Powder coated Grills for supply / Return air including all accessories complete Item100 4 M2
12 110 DRAIN PIPING\ni) 25 mm Item110 25 M
13 120 DRAIN PIPING\nii) 32 mm Item120 100 M
14 130 Canvass connection Item130 10 EA
15 140 ODU Structure Wall split AC\nSupplying and installation of M.S. fabricated ODU Structure installation with all accessories for Wall split AC Item140 1 EA
16 150 ODU Structure Ductable AC\nSupplying and installation of M.S. fabricated ODU Structure installation with all accessories for Ductable AC Item150 4 EA
17 160 Power/ control cabling 3c x 2.5 sq. mm.\nSupply and installation of electrical Power/ control cabling of suitable size between indoor units and indoor units Item160 550 M
18 170 DISMANTLING ALUM. / GYPSUM CEILINGS ETC.\nDismantling aluminum/Gypsum partitions, doors, windows, fixed\nglazing and false ceiling including disposal of unserviceable surplus\nmaterials and stacking of serviceable material with in 50 meters\nlead as directed by Engineer-in-charge Item170 50 M2
19 180 12.5 mm thick tapered edge gypsum moisture resistant board Item180 70 M2
20 190 Two or more coats applied on walls @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10 sqm. Item190 70 M2
21 200 Providing and applying plaster of paris putty of 2mm thickness over\nplastered surfaces to prepare the surface even and smooth complete Item200 70 M2
22 210 HAND RAILS\nProviding and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony\nrailing & stair case railing & stair case railing including applying a priming coat of approved steel primer.\nM.S. TUBE Item210 30 KG
23 220 With cement issued at issue rates from Owner's Stores, including transportation from Stores to work site and returning all excess/ unused cement to Owner' Storeage point after completion of work- Washed stone aggregate 20 mm nominal size Item220 2 M3
24 230 Area indexation @ 26.73% Item230 1 LS