| 1 | 1 | Wiring for light point/fan point with 1.5 Sq mm FR PVC insulated copper conductor Multy strand single core cable including earth wire, casing and capping/PVC Conduit as per required.\nIncluding Modular Holders, Regulators, 10 Amps switch with mounting box & etc.\n\nWire: - Havel’s/V Guard/Polycab.\nSwitches:-Roma/Legrand/V Guard/GM/Schneider. \n | item1 | 42 | Points |
|---|
| 2 | 2 | Wiring for Socket point with 4 Sq mm FR PVC insulated copper conductor Multy strand single core cable including earth wire, casing and capping/PVC Conduit as per required.\nIncluding Modular 10 Amps and 20 Amps switches and 5 pin Sockets to be fixed in a 6 Modular mounting box and Plate. (1 set).\nWire: - Havel’s/V Guard/Polycab.\nSwitches: - Roma/Legrand/V Gurad. \n | item2 | 26 | Points |
|---|
| 3 | 3 | Wiring for A.C point with 4 Sq mm FR PVC insulated copper conductor Multy strand single core cable including earth wire, casing and capping/PVC Conduit as per required.\n\nWire: - Havel’s/V Guard/Polycab.\n | item3 | 6 | Long Points |
|---|
| 4 | 4 | 3 Phase Wiring for MCB by using 6.0 Sq mm FR PVC insulated copper conductor Multy strand single core cable including Neutral and earth wire connections, casing and capping/PVC Conduit as per required.\nWire: - Havel’s/V Guard/Polycab.(8 Mtrs +18 Mtrs)\n | item4 | 26 | RMT |
|---|
| 5 | 5 | Supplying and fixing of 32 A 4 pole MCB with metal box. \n (Havel’s/Indo Asian).\n | item5 | 2 | Sets |
|---|
| 6 | 6 | Supplying and fixing of AC Starter or 2 pole MCB with metal box. \n (Havel’s/Indo Asian/V Guard).\n | item6 | 6 | Sets |
|---|
| 7 | 7 | Supplying and fixing with 12 way SDB box with MCB’s. (for Lighting Points).\n 10 Amps SP MCB -- 8 Nos \n 25 Amps DP MCB -- 1 No for Mains.\n(Indo Asian/Legrand/Havel’s/ Schneider)\n | item7 | 1 | Job |
|---|
| 8 | 8 | Supplying & Fixing 36 way 3 Phase DB box with 125 A 4P MCCB for Mains including following MCB’s.\n63 A 3P MCB for 3 Phase Points (3 No’s)\n32 A SP MCB for Power points. (3 No’s)\n20 A SP MCB for Power points. (20 No’s)\n (Indo Asian/Legrand/Havel’s/ Schneider) \n | item8 | 1 | Job |
|---|
| 9 | 9 | Supplying and fixing of 18-20 W LED tube light fittings as required at site. (EESL/Havel’s/Syska/Philips) | item9 | 20 | Nos |
|---|
| 10 | 10 | Supplying and fixing 40W LED street light fittings including connection as required at site (Control Switch should be provided outside)\n(Usha/Crompton/Havel’s/Bajaj/EESL/Syska)\n | item10 | 4 | Nos |
|---|
| 11 | 11 | Supplying and fixing 1400 mm sweep ceiling fan including connections, testing, commissioning & etc as required. (Usha/Crompton/Havel’s/Bajaj/EESL) | item11 | 10 | Nos |
|---|
| 12 | 12 | Supplying and fixing 300 mm Exhaust fan including connections, testing, commissioning & etc as required. (Usha/Crompton/Havel’s/Bajaj/EESL) | item12 | 6 | Nos |
|---|
| 13 | 13 | Wiring for Intercom connections by using casing and capping/Concealed by using 4 Pair cable with I/O boxes.\n(All the points should be terminated at one end for fixing of 20 Pair Telephone DB Box) as per the site condition.\n | item13 | 12 | Points |
|---|
| 14 | 14 | Supply of Telephone instruments Table top type. (Beetle). | item14 | 12 | Nos |
|---|
| 15 | 15 | Wiring for LAN connections by using casing and capping/concealed by using CAT 6 with provision for fixing D link I/O box.\n(All the points should be terminated at one end for fixing of internet HUB) as per the site condition.\n | item15 | 12 | Points |
|---|
| 16 | 16 | Supply and Installation of 20 Pair water proof Distribution box (for Intercom connections) with Krone module and installation and termination. | item16 | 1 | No |
|---|
| 17 | 17 | Providing Earthing connection as per IE specification, using 8 SWG, Copper wire & Copper plate of 350mm X 350 mm X 6 mm with penal system and 1.5 inch GI pipe ‘C’ class using charcoal salt etc at a depth of three meters with cement chamber and funnel type, complete as Indian Electricity Standards and site requirements (Connecting upto end points). | item17 | 2 | Sets |
|---|
| 18 | 18 | Supplying and laying of fallowing sizes of PVC insulated Alluminium conductor wired Armored UG cable in DWC Pipe double walled corrugated high density poly ethylene pipe having corrugation on the outer wall 70 mm and plain surface inner wall of 65 mm sizes conforming to IS14930, with necessary DWC fitting for protection of 1.1 KV grade UG Cable directly in ground at a depth of 3 feet including excavation and refilling the trench (including earthing and end termination) etc. as required at the site. \nRoot markers also to be fixed directly in to the ground.\n (V guard, Havel’s & Poly cab with ISI).\n70 sq mm x 3.5 core.\n | item18 | 130 | Mtrs |
|---|