Kerala State Electricity Board-KSEB has published Constructing 3Km 11Kv Oh Line Kayamkulam East Constructing 3Km 11Kv Oh Line And 200Mt Ug Cable From Ikkara To Onamkutty Research Trf For Avoiding Cross Country Line Under Ele . Section , Kayamkulam East Work Code 553134112000190. Submission Date for this Tender is 29-12-2020. Overhead Line Tenders in Kayamkulam Kerala. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 26-Dec-2020 | Time extension | Date | 29-12-2020 |
Name of Work: CONSTRUCTING 3KM 11KV OH LINE & 200MT UG CABLE FROM IKKARA TO ONAMKUTTY RESEARCH TRF FOR AVOIDING CROSS COUNTRY LINE under Ele. Section, Kayamkulam East - Work code 553134112000190 | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Labour portion | BI01010001010000000000000515BI0100001112 | ||
2 | 1.01 | Loading HT PSC pole to Hand cart from the stacking place and unloading the same at work site. | BI01010001010000000000000515BI0100001113 | 50 | No |
3 | 1.02 | Transporting one HT PSC pole by Hand cart (limited to 4km). | BI01010001010000000000000515BI0100001114 | 50 | P/km |
4 | 1.03 | Loading HT 'A' type pole to Hand cart from the stacking place and unloading the same at work site. | BI01010001010000000000000515BI0100001115 | 12 | No |
5 | 1.04 | Transporting 'A' type pole by Hand cart (limited to 4km). | BI01010001010000000000000515BI0100001116 | 12 | P/km |
6 | 1.05 | Fitting and erecting one HT PSC Pole in position incl. fitting cross arm, digging & back filling pit, drawing earth leads. | BI01010001010000000000000515BI0100001117 | 105 | No |
7 | 1.06 | Fitting and erecting one HT 'A' type Pole in position incl. fitting cross arm, digging & back filling pit, drawing earth leads. | BI01010001010000000000000515BI0100001118 | 10 | No |
8 | 1.07 | Additional rate for providing one disc set on any type of HT pole for making cut point. | BI01010001010000000000000515BI0100001119 | 84 | No |
9 | 1.08 | Fitting and erecting one HT DP using PSC pole in position incl. fitting 2 channel cross arms, digging & back filling pit, drawing earth leads. | BI01010001010000000000000515BI0100001120 | 5 | No |
10 | 1.09 | Fitting and erecting one HT DP using 'A' type pole in position incl. fitting 2 channel cross arms, digging & back filling pit, drawing earth leads. | BI01010001010000000000000515BI0100001121 | 1 | No |
11 | 1.1 | Fitting and providing one HT Stay for 11kV pole incl. digging & back filling pit. | BI01010001010000000000000515BI0100001122 | 75 | No |
12 | 1.11 | Fitting and providing one Strut using HT PSC pole incl. digging & back filling pit. | BI01010001010000000000000515BI0100001123 | 30 | No |
13 | 1.12 | Fitting and providing one Strut using 'A' type pole incl. digging & back filling pit. | BI01010001010000000000000515BI0100001124 | 2 | No |
14 | 1.13 | Stringing of one km 11kV line with ACSR Raccoon (3 conductors) incl. cutting and removing tree branches wherever necessary. | BI01010001010000000000000515BI0100001125 | 3.2 | km |
15 | 1.14 | Providing one Earth using earth pipe incl. digging separate pit at standard distance away from the pole/structure & backfilling. | BI01010001010000000000000515BI0100001126 | 7 | No |
16 | 1.15 | Providing one Coil Earth using GI earth wire, digging separate pit at standard distance away from the pole/structure & backfilling. | BI01010001010000000000000515BI0100001127 | 108 | No |
17 | 1.16 | Fitting one set AB switch and giving connection | BI01010001010000000000000515BI0100001128 | 7 | No |
18 | 1.17 | Fitting one Additional 75x40mm, 1.8m Channel cross arm in existing single pole incl. conveyance of materials. | BI01010001010000000000000515BI0100001129 | 48 | No |
19 | 1.18 | Fitting one Additional 2.4m/3m Channel cross arm (75x40x6mm), in existing 11kV DP incl. conveyance of materials. | BI01010001010000000000000515BI0100001130 | 33 | No |
20 | 1.19 | Fitting one LT 2 line cross arm on HT or LT existing poles incl. fitting insulators and binding the same with LT Line. | BI01010001010000000000000515BI0100001131 | 50 | No |
21 | 1.2 | Fitting one LT 4 line cross arm on HT or LT existing poles incl. fitting insulators and binding the same with LT Line. | BI01010001010000000000000515BI0100001132 | 60 | No |
22 | 1.21 | Erecting one LT PSC Pole in position incl. digging & back filling pit. | BI01010001010000000000000515BI0100001133 | 5 | No |
23 | 1.22 | Drilling hole of various sizes on existing Channel/Cross Arm. | BI01010001010000000000000515BI0100001134 | 30 | No |
24 | 1.23 | Additional rate for refitting/redoing one Shackle set and reshackling one span while renewing any type of pole. | BI01010001010000000000000515BI0100001135 | 120 | No |
25 | 1.24 | Transferring LT 3ph 4/5 wire OH line to newly erected HT/LT pole and refitting all items to the new pole. | BI01010001010000000000000515BI0100001136 | 35 | No |
26 | 1.25 | Reconductoring one km LT 3ph 4 wire OH old line with new 3 ACSR Rabbit and one Weasel conductor incl. conveyance of materials. | BI01010001010000000000000515BI0100001137 | 2.5 | km |
27 | 1.26 | Reconductoring one km LT OH one old conductor with New ACSR Rabbit conductor incl. conveyance of materials. | BI01010001010000000000000515BI0100001138 | 2.5 | km |
28 | 1.27 | Dismantling and reconnecting Sph service connection from the OH line incl. lowering down the WP portion. | BI01010001010000000000000515BI0100001139 | 120 | No |
29 | 1.28 | Dismantling and reconnecting 3ph service connection from the OH line incl. lowering down the WP portion. | BI01010001010000000000000515BI0100001140 | 10 | No |
30 | 1.29 | Dismantling one damaged LT PSC/RCC pole after disconnecting stays, strut etc. and stacking the same. | BI01010001010000000000000515BI0100001141 | 15 | No |
31 | 1.3 | Dismantling (without damage) one LT PSC/RCC pole after disconnecting stays, strut etc. and stacking the same. | BI01010001010000000000000515BI0100001142 | 100 | No |
32 | 1.31 | Dismantling one ordinary street light/CFL/LED fitting from existing pole and refitting the same on newly erected pole and reconnecting. | BI01010001010000000000000515BI0100001143 | 40 | No |
33 | 1.32 | Cutting trees beyond 30cm but upto and incl. 60cm girth, cutting of trunks/branches, removing the root completely and stacking. | BI01010001010000000000000515BI0100001144 | 40 | No |
34 | 1.33 | Cutting trees beyond 60cm but upto and incl. 120cm girth, cutting of trunks/branches, removing the root completely and stacking. | BI01010001010000000000000515BI0100001145 | 200 | No |
35 | 1.34 | Cutting trees beyond 120cm but upto and incl. 180cm girth, cutting of trunks/branches, removing the root completely and stacking. | BI01010001010000000000000515BI0100001146 | 16 | No |
36 | 1.35 | Loading HT PSC pole from the stacking place and unloading the same at work site (transport by vehicle). | BI01010001010000000000000515BI0100001147 | 150 | No |
37 | 1.36 | Loading HT 'A' type pole from the stacking place and unloading the same at work site (transport by vehicle). | BI01010001010000000000000515BI0100001148 | 12 | No |
38 | 1.37 | Excavation of cable trench in all classes of soil and backfilling after laying of cable (excluding laying of cable). | BI01010001010000000000000515BI0100001149 | 200 | m |
39 | 1.38 | Laying HT XLPE UG cable (of sizes beyond 3x185 sqmm and upto and incl. 3x300 sqmm) as per specification excl. excavation and backfilling. | BI01010001010000000000000515BI0100001150 | 300 | m |
40 | 1.39 | Doing straight joint on cables of sizes beyond 3x185 sqmm and upto and incl. 3x300 sq mm using the cable jointing kit supplied departmentally as per specification. | BI01010001010000000000000515BI0100001151 | 1 | No |
41 | 1.4 | Doing one cable end termination on cables of sizes beyond 3x185 sqmm and upto and incl. 3x300 sq mm using the cable jointing kit supplied departmentally. | BI01010001010000000000000515BI0100001152 | 6 | No |
42 | 1.41 | Mounting the cable ends of all sizes upto and incl. 3x300 sq mm with special type cable clamps incl. cost of extra materials if needed and giving necessary connections. | BI01010001010000000000000515BI0100001153 | 6 | No |
43 | 1.42 | Providing concrete muffing (0.45x0.45x1.5m) inclusive of cost of all material (as per specification). | BI01010001010000000000000515BI0100001154 | 12 | No |