Military Engineer Services-MES has published Repair And Maint Of Summer Cooling Appliances Under Ge ( West ) Jabalpur. Submission Date for this Tender is 09-01-2021. Air Conditioner Tenders in GE (West) Jabalpaur Madhya Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 02-Jan-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-01-2021 |
Name of Work : REPAIR AND MAINT OF SUMMER COOLING APPLIANCES UNDER GE (WEST) JABALPUR | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Material & Labour for replacement of old / Unserveciable compressor with new sealed unit compressor company fabricated with all accessories such as starter, running capacitor & over load wiring of existing makes/model for the water cooler, Deep Freezer & Refrigerator including first fill of refrigerant gas, brazing jointing, leak proof testing & commissioning complete all as specified & directed for the following :- | |||
2 | 2 | (a) Compressor suitable for Water cooler capacity 60/120 Litre\nMake : Godrej / Voltas / Bluestar | 15 | Each | |
3 | 3 | (b) Compressor suitable for Water cooler capacity 150/150 Litre \nMake : Godrej/ Voltas/ Bluestar | 10 | Each | |
4 | 4 | (c) Compressor suitable for Water cooler capacity 40/80 Litre \nMake : Godrej/ Voltas / Bluestar | 10 | Each | |
5 | 5 | (d) Compressor suitable for Deep Freezer capacity 320 Litre \nMake : Godrej/ Voltas / Bluestar | 10 | Each | |
6 | 6 | (e ) Compressor suitable for refrigerator capacity 165 Litre \nMake Godrej /Tecumesh | 15 | Each | |
7 | 7 | (f ) Compressor suitable for refrigerator capacity 280 Litre\nMake Godrej /Tecumesh | 10 | Each | |
8 | 8 | (g ) Compressor suitable for refrigerator capacity 310 Litre\nMake Godrej /Tecumesh | 15 | Each | |
9 | 9 | Material & Labour for replacement of Old Unserviceable compressor with new sealed unit compressor, company fabricated with all accessories such as starting running capacitor & over load with wiring of existing Make/model for the window AC and Split AC including first fill of refrigerant gas, brazing jointing, leak proof testing & commissioning for the following :- | |||
10 | 10 | (a) Compressor hermatic type Suitable for 1.0 Ton AC window type | 10 | Each | |
11 | 11 | (b) Compressor hermatic type Suitable for 1.5 Ton AC window type | 15 | Each | |
12 | 12 | (c) Compressor hermatic type Suitable for 2.0 Ton AC window type | 10 | Each | |
13 | 13 | (d) Compressor rotary screw type Suitable for 1.5 Ton AC split type | 15 | Each | |
14 | 14 | (e) Compressor rotary screw type Suitable for 2.0 Ton AC split type | 3 | Each | |
15 | 15 | (f) Compressor inbuilt invertor type Suitable for 1.5 Ton AC split type | 5 | Each | |
16 | 16 | Material & Labour for Rewinding of fan motor of water cooler, desert cooler and AC with super enameled copper winding wire of existing gauge including insulation, warnishing etc, and replacement of worn out bushes, bearings, shafts, nuts, bolts and washers includind greasing, oiling, reassembling and testig the motor complete all as specified and directed for the following capacities:- | |||
17 | 17 | (a) 1/7 HP Suitable for Desert cooler | 15 | Each Job | |
18 | 18 | (b) 1/10 HP and 1/35 HP Suitable for water cooler | 15 | Each Job | |
19 | 19 | (c ) 1/4 HP and 1/6 HP Suitable for AC any type | 15 | Each Job | |
20 | 20 | Replacement new PCB (printed circuit board ) units as existing model/make for split AC 1.5/2 Ton capacity complete all as specified and directed . Make:Blue star/Voltas/LG/Samsung | 15 | Each | |
21 | 21 | Replacement Old/UNSV with new water lifting pump suitable for Desert cooler of 1/20 Hp, 240 volts, 50 Hz, 12 watts, 1.5 mtr head capacity complete all as specified and directed .Make:Crompton /Khaitan/Kenstar | 60 | Each | |
22 | 22 | S & F PVC switch box including two switch & indicater of Plaza Make for Desert cooler including taking down old switch box. | 15 | Each | |
23 | 23 | S & F new five speed regulator for Desert cooler 240 volts 50 Hz, single phase, including taking down old switch ,complete any make and any size of Make : PLAZA/KINJAL/ANCHOR | 50 | Each | |
24 | 24 | S & F Nobs for window AC , including taking down old switch complete any make and any size,. | 20 | Each | |
25 | 25 | S & F AC contactor MP-11 suitable for window AC /split AC 1.5/ 2 TR ,240 volts 50 Hz, single phase including taking down old AC contactor MP-11 complete all as specified and directed . | 20 | Each | |
26 | 26 | S& in replacement Desert cooler water tank suitable for Desert cooler (as per existing size) made out of 22 gauge GI sheet made to shape including complete all as specified and directed . | 20 | Each | |
27 | 27 | S&F in replacement water cooler float valve PVC ISI mark size 15 mm, with ball rod for water cooler any cap/make complete all as specified and directed . Mark : Prayag | 50 | Each | |
28 | 28 | S & F in replacement Suction valve/Liquid valve of size 1/2" & 1/4" along with dead nut complete suitable for split AC cap 1.5/2 Ton out door unit complete all as specified and directed by Engr-in-Charge. | 20 | Each | |
29 | 29 | S&F Refrigaretor Lamp/bulb 310Ltrs/280ltrs/165 ltrs, (thread or pin type),15 volts, 240 volts 50 Hz, single phase including taking down old Lamp complete all as specified and directed . | 15 | Each | |
30 | 30 | S&F door switch of refrigerator 240 volts 50 Hz, single phase suitable for existing make of refrigerator including taking down old Lamp complete all as specified and directed . | 10 | Each | |
31 | 31 | S & F in replacement GI tubing 15 mm dia medium grade with all fittings such as elbow,tee,union ,socket etc complete all as specified and directed by Engr-in-Charge. | 50 | RM | |
32 | 32 | S & F in replacement PVC tubing 15 mm dia heavy duty to fixed on wall/floor with suitable clamps with all PVC fittings such as elbow,tee,union ,socket ISI mark Complete all as specified and directed by Engr-in-Charge. | 50 | RM | |
33 | 33 | M&L for Preparation of surfaces and applying two coat of synthetic enamel spray painting on metal surface (inner/outer) including writing SM No/MES No with paint to following items complete all as specified and directed . | |||
34 | 34 | (a) Water cooler of any make and size | 10 | Each | |
35 | 35 | (b) Desert cooler of any make and size | 10 | Each | |
36 | 36 | (c) Refrigerator cap 165 ltrs | 10 | Each | |
37 | 37 | (d) Refrigerator cap 280 and 310 ltrs | 10 | Each | |
38 | 38 | (e) Deep Freezer of any make and size | 10 | Each | |
39 | 39 | Replacement of Old/UNSV with new wood wool pads of required size for Desert cooler any make including complete all as specified and directed . | 100 | set of 3 pad | |
40 | 40 | Replacement of Old/damaged with new front Grill made out of 22 gauge GI sheet suitable for Desert cooler any make/size complete all as specified and directed . | 30 | Each | |
41 | 41 | Repair/replacement of damaged body of Desert cooler, water cooler,Deep Freezer with 1 mm thick MS sheet any make complete all as specified and directed . | 15 | SQM | |
42 | 42 | S & F in replacement of old/UNSV fan motor, single phase, 230 volt ,50 Hz ,1/7 HP with blade arm 18" sweep size suitable for Desert cooler, complete all as specified and directed. Make: Khaitan/Champion/Jyoti | 40 | Each | |
43 | 43 | S & F in Replacement of defective / damaged transformer of voltage stabilizer complete all as specified and directed of following capacity:- | |||
44 | 44 | (a) 5 KVA | 5 | Each | |
45 | 45 | (b) 4 KVA | 5 | Each | |
46 | 46 | (c ) 3 KVA | 5 | Each | |
47 | 47 | (D) 0.5 KVA | 5 | Each | |
48 | 48 | S & F in Replacement of volt meter range 0 to 300 volts, flush type square or circular for voltage stabilizer complete all as specified and directed. | 10 | Each | |
49 | 49 | Supplying and fixing in Replacement of liner (cold gold model) for refrigaretor capacity 165 ltr complete all as specified and directed. | 10 | Each | |
50 | 50 | Ditto all as per above items but capacity 310 Ltr | 10 | Each | |
51 | 51 | Replacement of old/UNSV fan motar 230 volt ,50 Hz for following items complete all as specified and directed . Make: Crompton | |||
52 | 52 | (a) 1/10 HP of Water cooler cap 150/150 ltr | 10 | Each | |
53 | 53 | (b) 1/35HP of Water cooler cap 60/120 ltr | 10 | Each | |
54 | 54 | (c ) 1/20 HP suitable size of water cooler cap 40/80 ltr | 10 | Each | |
55 | 55 | (d ) 1/20 HP for deep freezer cap 310 ltr) | 10 | Each | |
56 | 56 | (e ) 1/4 and 1/6 HP suitable for AC window type and split type | 20 | Each | |
57 | 57 | Re-filling of Refrigerent gas Non CFC R 22 of Window AC & Split AC of capacity 1.5 Tr including breezing, jointing,leak testing ,commissioning,taking down and refixing complete all as specified and directed . | 70 | Kgs | |
58 | 58 | Re-filling of Refrigerant gas Non CFC (R-134 A) of Refregirator, water Cooler and Deep Freezer of any capacity including brazing, jointing,leak testing ,commissioning,taking down and refixing complete all as specified and directed . | 70 | Kgs | |
59 | 59 | Replacememt of Old/UNSV submain wiring with two run of PVC insulated cable of size 4 sqmm copper conductor (Multi strand) drawing into existing surfaces/ concealed conduit including PVC 2.5 sqmm multi strand copper conductor cable as continious earth wire complete and making good distrubed surfaces of wall /floor etc complete all as specified and directed. | 100 | RM | |
60 | 60 | Taking down carefully following item of any make/model after repair refixing of same or other position or depositing in MES store of AGE E/M (W) W/S Jabalpur complete all as specified and directed. | |||
61 | 61 | (a) Water cooler of any make and size | 20 | Each | |
62 | 62 | (b) Desert cooler of any make and size | 100 | Each | |
63 | 63 | (c) Window AC/Split AC of any capacity /position | 20 | Each | |
64 | 64 | (d) Refrigerator of any capacity /position | 15 | Each | |
65 | 65 | (e) Deep Freezer of any make and model | 10 | Each | |
66 | 66 | Servicing of summer cooling appliances including pressure testing of AC ,cleannig of indoor unit with blower & outdoor unit of AC washing, filter cleaning,copper tubing check etc, complete all as specified and directed by Engr-in-Charge. | |||
67 | 67 | (a) Water cooler of any make and size | 100 | Each | |
68 | 68 | (b) Desert cooler of any make and size | 100 | Each | |
69 | 69 | (c) Window AC/Split AC | 100 | Each | |
70 | 70 | Replacement of Old/UNSV Ply-wood grade BWR type BB 6mm thick (five Ply) cut into required size fixed where required with all fixing are complete all as specified and directed. | 15 | Sqm | |
71 | 71 | Replacement of old/UNSV Running capacitor of Air condition following capacity, any type and any make . | |||
72 | 72 | (a) 50 MFD | 15 | Each | |
73 | 73 | (b) 36 MFD | 15 | Each | |
74 | 74 | (c ) 15 MFD | 15 | Each | |
75 | 75 | (d) 10 MFD | 15 | Each | |
76 | 76 | (e) 6 MFD | 15 | Each | |
77 | 77 | (f) 4 MFD | 15 | Each | |
78 | 78 | (g) 2.5 MFD | 15 | Each | |
79 | 79 | S&F in Replacement new Thermostate for AC,any type and any make | 20 | Each | |
80 | 80 | S&F in Replacement of Old/damaged with new Chromium plate flush type Bib cock of 15mm dia for water cooler any type and any make complete all as specified and directed by Engr-in-Charge. . | 30 | Each | |
81 | 81 | S&F in replacement of Thermostate for water cooler of any type and any make /capacity complete all as specified and directed by Engr-in-Charge. .. | 20 | Each | |
82 | 82 | S&F in replacement of Over load protector for water cooler, as per existing size and make. | 20 | Each | |
83 | 83 | S&F in replacement installation and testing copper tubing of size 1/2" &1/4" along with sleeve insulation complete all as specified and directed by Engr-in-Charge. .. | 100 | RM | |
84 | 84 | S & F in replacement switch socket combination flush type 5 Amps including Make : PLAZA/KINJAL/ANCHOR | 40 | Each | |
85 | 85 | M & L for fabrication of angle iron frame with equal angle of size 40x40x 6 mm suitable out door unit window/split AC 1.5/2 Ton capacity incl PCC work and fixing arrangement complete all as directed by Engr-in-Charge . | 50 | Kg | |
86 | 86 | S & F in repairs single pole and neutral encloser with two pin and earth plug and socket complete with one MCB SP 32/20 Amps complete all as directed by Engr-in-Charge . Make: L & T/Legrarnd/Schinder. | 20 | Each | |
87 | 87 | S & F in repairs Sheet metal encloser double door enclosur with MCB DB SPN complete all as directed by Engr-in-Charge . | 3 | Each | |
88 | 88 | S & F in repairs MCB SP, 230 volts, 20 to 32 amps as per complete all as directed by Engr-in-Charge . | 15 | Each | |
89 | 89 | S & F in repairs MCB SPN, 230 volts, 32 to 40 amps as per complete all as directed by Engr-in-Charge . | 15 | Each | |
90 | 90 | S&F in repairs Three core copper flexible wire PVC insulated cable and PVC sheathed of size 40/0.076 mm complete all as specified and directed. | 100 | RM | |
91 | 91 | S & F in repairs three pin plug top 16 amps ISI mark complete all as directed by Engr-in-Charge . Make : PLAZA/KINJAL/ANCHOR | 40 | Each | |
92 | 92 | S & F in replacement of PVC connection ISI mark 15 mm dia & 60 cm long complete with rubber washer for water cooler complete all as specified and directed. | 30 | Each | |
93 | 93 | S & F MS fan blade suitable for follwing sizes including taking out of old unserviceble blade | |||
94 | 94 | (a) 450mm | 10 | Each | |
95 | 95 | (b) 380mm | 10 | Each | |
96 | 96 | (c ) 300mm | 10 | Each | |
97 | 97 | S & F in replacement of heavy duty flexible PVC pipe 15 mm bore for desrt cooler complete all as specified and directed. | 50 | RM | |
98 | 98 | S & F in repairs air filter suitable for 1.5/2 Ton split AC as per existing size complete all as directed by Engr-in-Charge . | 20 | Each | |
99 | 99 | S & F in repairs black insulation cover suitable for copper tubing any of size complete all as directed by Engr-in-Charge . | 80 | RM | |
100 | 100 | Re-filling of Refrigerent gas Non CFC R 410 of Window AC & Split AC of capacity 1.5 Tr including breezing, jointing,leak testing ,commissioning,taking down and refixing complete all as specified and directed . | 50 | Kgs | |
101 | 101 | Replacement of Old/UNSV PCB with new inbuilt inverter type PCB(printed circuit board ) units as existing model/make for split AC 1.5/2 Ton capacity complete all as specified and directed . Make:Blue star/Voltas/LG/Samsung | 6 | Each | |
102 | 102 | S & F in replacement swing motor of split AC cap 1.5/2 Ton, any type and any make/model complete all as specified and directed by Engr-in-Charge .Make: LG/Voltas | 15 | Each | |
103 | 103 | S & F in replacement water tray suitable for split AC 1.5/2 Ton capacity, any type and any make/model complete all as specified and directed by Engr-in-Charge .Make: LG/Voltas | 15 | Each | |
104 | 104 | S & F in replacement condensor Coil of window type/ split type AC cap 1.5/2 Ton any type and any make/model complete all as specified and directed by Engr-in-Charge . | 10 | Each | |
105 | 105 | S & F in replacement cooling coil of window type/split type AC cap 1.5/2 Ton, any type and any make/model complete all as specified and directed by Engr-in-Charge . | 10 | Each | |
106 | 106 | S & F in replacement of wiring kit of window type AC of cap 1.5/2 Ton, any type and any make/model complete all as specified and directed by Engr-in-Charge . | 10 | Each | |
107 | 107 | S & F in replacement of Freezer /Evaporator for refrigerator with freezer door of capacity 165, 280,310 ltrs any make/model complete all as specified and directed by Engr-in-Charge . | 10 | Each | |
108 | 108 | S & F in replacement of stainless steel tank of water cooler for all capacity of any make/model all as specified and directed. | 10 | Each | |
109 | 109 | S & F in replacement of condensing coil for refrigerator of capacity 165, 280,310 ltrs any make/model complete all as specified and directed by Engr-in-Charge . | 10 | Each | |
110 | 110 | S & F in repairs switch socket combination 16 Amp flush type, 240 Volts, 50 Hz of any make/model complete all as specified and directed by Engr-in-Charge . | 15 | Each | |
111 | 111 | S & F in repairs three pin plug top 16 amps ISI mark complete all as directed by Engr-in-Charge . Make : PLAZA/KINJAL/ANCHOR | 25 | Each | |
112 | 112 | Replacement of Old/UNSV PCB with new PCB(printed circuit board ) units as existing model/make for Window type AC 1.5/2 Ton capacity complete all as specified and directed . Make:Blue star/Voltas/LG/Samsung | 10 | Each | |
113 | 113 | S & F in replacement of remote control suitable for split AC cap 1.5/2 Ton, any type and any make/model complete all as specified and directed by Engr-in-Charge .Make: LG/Voltas/Bluestar/IFB | 5 | Each |