Provn Of Drainage ( Approx 650 Mtr ) And Standby Reserve Electric Geysers And Spl Repair/Renewal Of Bldg Earthings For Certain Md/Otm Accn Including Certain Minor Works/Arboriculture At Dinjan Mil Stn

Issued by Statutory Bodies & Commissions/Committees · DINJAN MIL STN, Assam
Tender Value
40.90 Lakhs
Estimated cost
Bid Submission
09 Jan 2021
0 days left
EMD
81800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
DINJAN MIL STN → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Provn Of Drainage ( Approx 650 Mtr ) And Standby Reserve Electric Geysers And Spl Repair/Renewal Of Bldg Earthings For Certain Md/Otm Accn Including Certain Minor Works/Arboriculture At Dinjan Mil Stn

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 24-Dec-2020 REVISED NIT Financial Bid 02-Jan-2021
2 02-Jan-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-Jan-2021

BOQ

Name of Work: PROVN OF DRAINAGE (APPROX 650 MTR) AND STANDBY RESERVE ELECTRIC GEYSERS AND SPL REPAIR/RENEWAL OF BLDG EARTHINGS FOR CERTAIN MD/OTM ACCN INCLUDING CERTAIN MINOR WORKS/ARBORICULTURE AT DINJAN MIL STN
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.404Cum
22Returning, filling in, including spreading in layers n.exc 25cm, levelling, watering and well ramming as in soft/loose soil complete all as specified and as directed.123Cum
33Removing excavated surplus materials to a distance not exc. 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.281Cum
44M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, filling, sub base of floors and mass concrete, etc complete all as specified and as directed.53.95Cum
55M&L for plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in surface channel, drains etc complete all as specified and as directed.26.96Cum
66M&L for brick work with sub class 'B' bricks, laid on flat, in drains, etc bedded and jointed in cement mortar (1:6) and pointed in cement mortar (1:3) complete all as specified and as directed.800Sqm
77M&L for brick work with sub class 'B' bricks, laid on edge, in floors, drains, etc bedded and jointed in cement mortar (1:6) and pointed in cement mortar (1:3) complete all as specified and as directed.279Sqm
88M&L for rendering 15mm thick in cement mortor (1:6) on fair faces of brick work and finishing surface even and smooth without using extra cement complete all as specified and as directed.1078Sqm
99M&L for plain Cement Concrete (1:2:4) type B-1, (using 20 mm graded stone aggregate) as in drain kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.4.2Cum
1010Extra for forming fair finished to concrete surface of drain 30cm inner girth in cement including forms, mould, mitred/stopped etc complete all as specified and as directed. (Inner girth only be measured).\n719RM
1111Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushing neat cement slurry with 3 Kg of cement per sqm on floor complete all as specified and as directed.52Sqm
1212M&L for vitrified, designed, coloured, tiles, 10 mm thick, (square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm in floors, etc including 15 mm thick screed bed or bedding in cement mortor (1:6) and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.90Sqm
1313M&L for vitrified, designed, coloured, tiles, 10 mm thick, (square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm as in skirting, etc including 10 mm thick screed bed or bedding in cement mortor (1:4) and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.8Sqm
1414Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed. \n8Sqm
1515Taking down shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each and refixing shutters in the same opening complete all as specified and as directed.3Per Leaf
1616M&L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, including 15 mm thick screed bed or bedding in cement mortor (1:6) and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.3.5Sqm
1717M&L for glazed, ceramic, coloured tiles of size 300mm x 200mm x 6-7mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick backing coat in cement mortor (1:4) and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.13.5Sqm
1818Taking up or down 15mm bore, steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning complete all as specified and as directed.\n10RM
1919Taking up or down 20mm bore, steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning complete all as specified and as directed.3RM
2020Supply, laying, connection and testing, 15mm bore, steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and as directed.10RM
2121Supply, laying, connection and testing, 20mm bore, steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and as directed.3RM
2222S&F for 15mm bore, bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.3Each
2323S&F for 15 mm bore, stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.3Each
2424M&L for clearance of area digging of pit size 0.60x0.60x0.60 m, removal of debris weeds, roots etc and refilling with good agriculture soil and well decomposed cattle mannure in ratio 3:1, supply and planting of approved species of plant of healthy grow up with good roots, (height of plant shall not be less than 0.60m) complete all as specified and as directed by Engr-in-Charge.\nNote : (i) Plant will be of any of these - Ashoka, Areca Palm, Coconut tree, litchi, Cycus etc.\n (ii) The period of irigation and weeding for the saplings shall be one year from the certified date of completion.\n(iii) The contractor shall be responsible for maintenance of the saplings during this period and any defects noticed or death of the sapling during this period shall be made good/replanted by him at his own cost.151Each
2525M&L for clearance of area, excavation upto 30cm depth, removal of debris, weeds, roots etc and refilling with good soil and well decomposed mannure in sand ratio 3:1, and treating with anty termite treatment @ 5 litre per sqm using LINDANE/CHLOPYRIOUS (EC-20) at plantation time and planting of normal doob grass complete all as approved and as directed by Engr-in-Charge.\nNote :- (i) The period of irigation and weeding for the saplings shall be one year from the certified date of completion.\n(ii) The contractor shall be responsible for maintenance of the saplings during this period and any defects noticed or death of the sapling during this period shall be made good/replanted by him at his own cost.25Sqm
2626Supply, Installation, testing & commissioning Geyser of capacity 25 Litres with inner tank coated with glass lined coating (Feroglass technology), with high density PUF insulation shock resistant ABS Body, 4 in 1 multifuctional valve, energy efficient BEE 5 star rated including fixing arrangement and suitable capacity flaxible 3 core copper cable of 1.5 metre to 2 metre length with 3-pin plug top of 16A capacity, necessary connection with and including PVC Connection pipe (2 Nos) of 600mm length for Hot and cold water, fixing on walls with and including all ncessary fitting material i.e. mild steel Bolts (Bolted to be grouted). Nuts, washers etc complete all as specified and as directed.\nMake : Cat No. AMICA ASWH-2025 of Crompton/Bajaj/Havells.\nNote : Contractor shall submit technical data/specifications & test report as specified, to the GE for approval of make and model.30Each
2727Supply, Installation, testing & commissioning Geyser of capacity 50 Litres with inner tank coated with glass lined coating (Feroglass technology), with high density PUF insulation shock resistant ABS Body, 4 in 1 multifuctional valve, energy efficient BEE 5 star rated including fixing arrangement and suitable capacity flaxible 3 core copper cable of 1.5 metre to 2 metre length with 3-pin plug top of 16A capacity, necessary connection with and including PVC Connection pipe (2 Nos) of 600mm length for Hot and cold water, fixing on walls with and including all ncessary fitting material i.e. mild steel Bolts (Bolted to be grouted). Nuts, washers etc complete all as specified and as directed.\nMake : Cat No. Radiant Neo ASWH-550 of Crompton/Bajaj/Havells.\nNote : Contractor shall submit technical data/specifications & test report as specified, to the GE for approval of make and model.8Each
2828M&L for earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete inclduing taking down existing earthing complete all as specified and as directed.\n244Each
2929S&F for earth continuity conductor or main earthing lead with galvanised iron wire 4mm dia, fixed to wall on batten or recesses or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing as required complete by removing the broken/damaged earth continuity complete all specification and as directed.732RM
3030M&L for 15 mm bore, steel tubes, galvanised, light grade with all fittings, fixed to walls, laid in floor/road crossing etc for GI wire protection complete all as specified and as directed.732RM
3131M&L for test point terminal box made of gun metal or phosphorous bronze, size 75x75x25mm, drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screw including removing the existing old unserviceable ones complete all as specified and as directed.244Each Job
3232M&L for making name board with 6mm thick PVC floor (Heavy duty, water proof) and writting the letters & font size (sticker type computer letters) as directed by Engr-in-charge and duly fixed to the wall/poles etc. with all fixing arrangement complete all as specified and as directed.8Sqm
3333M&L for making nitch in existing PCC floor for inserting pipe/strip etc. and making good the same by matching with existing complete all as specified and as directed.220RM
3434Repairs to earth chambers by demolishing unserviceable earth chambers and fixing new chambers of PCC (1:3:6) type C-1 as per electrical plate no.3 of SSR part-I complete all as specified and as directed.34Each Job
3535Supply, installing, commissioning, testing of Deep Freezer, 310 ltrs capacity, 230 volt, 50 Hz, aesthetic design, D-cool technology based, energy efficient & Eco-friendly refrigerant with R600a, having hard top single door, with anti bacteria gasket & rotary compressor incl stucco Aluminium inner liner for improved hygiene, spring loaded hibges, with freezer temparature range <-18ºC complete all as specified and directed\nMake : Model No. GCHW310R6SXB Htop of Godrej/Blue Star/Samsung/LG/Voltas.1Each
3636M&L for point wiring with 1.5 Sqmm (nominal area), FR PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FR PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches on Independent board complete all as specified and as directed.\n6Point
3737M&L for Point wiring with 2.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 2.5 Sqmm (nominal area) FRLHS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point terminated in and including 1.6mm thick mild steel sunken terminal box of suitable size with 3mm thick hylam sheet top cover fixed with suitable size of brass screws suitable sizes cadmium plated iron screws and washers etc. for mounting one 6/16 Amps switch socket combination on Independent board complete all as specified and as directed.1Point
3838S&F for switch piano, 5 Amp single pole, flush type one way 230 volts complete all as specified and as directed.6Each
3939S&F for socket outlet, 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed.6Each
4040S&F for switch socket combination, 5 in 1, 6/16 Amps, 240 volts, flush type with fuse & neon indicator complete all as specified and as directed.4Each
4141M&L for sub main wiring with two runs of 4 sqmm (Nominal area) single core cable FR PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through PVC conduits/casing-caping of suitable size, fixed to wall/ceiling etc including 4 sqmm (nominal area) single core, FR PVC insulated, multistranded, unsheathed, copper conductor as earth wire and duly connected to common earth point including PVC conduits/casing-caping of suitable size complete all as specified and as directed by Engineer-in-charge.\nNote : PVC Conduits/Casing-caping, two run cables and one run of earth wire will be measured as one length.15RM
4242M&L for sub main wiring with two runs of 2.5 sqmm (Nominal area) single core cable FR PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through PVC conduits/casing-caping of suitable size, fixed to wall/ceiling etc including 2.5 sqmm (nominal area) single core, FR PVC insulated, multistranded, unsheathed, copper conductor as earth wire and duly connected to common earth point including PVC conduits/casing-caping of suitable size complete all as specified and as directed.\nNote : PVC Conduits/Casing-caping, two run cables and one run of earth wire will be measured as one length.26RM
4343Supply only electric driven submersible pump set, 415 V, 3 phase, 20 HP suitable for proposed bore well & required discharge approx 700 LPM at approx 200 meter Head, complete all as specified and as directed.\nMake : Kirlosker/KSB/Crompton Greaves.\nNote: In case the pump-motor set specified as above does not suit for the desired yield of water in bore well, the capacity of the pump-motor set shall be redesigned subject to price adjustment.1Each
4444Supply, installation, testing and commissioning of centrifugal pumping sets of 12.5 HP, Horizontal, dicharge approx 900 LPM at head of approx 80 meter, working on 415V, 3 phase, 50 Hz, A.C. supply with Gun metal impeller and having suction and delivery of 80 X 65 mm, duly mounted on channel iron base stand including firmly grouted in PCC 1:3:6 and cabling as well as priming arrangements all as specified and as directed.\nMake : Kirlosker/KSB/Crompton Greaves.1Each
4545M&L for cutting and screwing of existing tubing of size 80mm for additions or alteration of pipe complete all as specified and as directed.2Each
4646Supply, laying, connection and testing, 80mm bore, steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floor etc. complete all as specified and as directed.1RM
4747S&F for 80mm bore, cast iron sluice valve both end flanged, class PN 1.6 conforming to relevant IS with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer & rubber/fiber board gasket complete all as specified and as directed.2Each
4848S&F for automatic hand dryer, 1800W ( ISI Marked ), 220 volt, sensor type, drying time<10 second and mounted to wall with all necessary fixing arrangement complete all as specified and as directed..6Each
4949S&F for automatic sensor Soap dispensers with required fixing arrangement with effective range of 0-10cm underneath the senser, low volt indicator to remind batery replace with batery powered sensor pump complete all as specified and as directed.\nNote : Rate of 04 Nos AA size rechargable batery cell shall be included in above qouted rate.6Each
5050Supply, installation, commissioning and testing of Inverter technology, Hot & Cold, Split Type Wall mounted Air Conditioner (indoor & outdoor unit with cordless remote control unit) of Cap 1.5 TR , BEE 5 Star rating, fitted with rotary compressor (5 year Warranty), copper condencing unit, Refrigerant type R-410A/R-32 or latest type, cooling capacity nominal (4500 Kcl/Hrs) including , PVC FRLS grade multi stranded copper conductor cable 3 core 2.5 Sqmm for connections with outdoor unit, clamps, nuts, bolts washers drilling holes on walls/ceiling for connection/drain pipes and making good the disturbed surfaces of wall with cement mortar, white cement and painting works to match the existing surfaces of walls complete all as specified and as directed.\nMake : Model No. FTXF50TV16 of DAIKIN/Model No. RSOG517HDXA of Hitachi or equivalent model of make Blue Star/Voltas/Godrej/Carrier.\nNote : (i) PVC drain pipes of suitable size & heavy duty Copper connection pipes including suitable insulation upto 3 Mtrs are deemed to be included in above quoted rate. \n(ii) PVC drain pipes of suitable size & heavy duty copper connection pipes including suitable insulation exceeding 3 Mtrs shall be measured and paid separately under relavent item.2Each
5151S&F for voltage Stabilizer of capacity 4.0 kVA, suitable for AC 1.5 TR wall mounted type, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5% with latest technology for protective relays complete all as specified and as directed.\nMake : Venus/V Guard/Whirlpool.\n2Each
5252Supply, fixing, commissioning and testing air curtains with remote and In-built sensor for door size upto 6 ft, wall mounted, casing made in metal body with powder coating with horizontal air intake centrifugal, housing with unique design, uniform air flow alongwith switch to control high & low speed, blower are made of high quality ABS to ensure less noise ( Noise level <68db ), working at 750W and 220 Volt, complete all as specified and as directed.3Each

AI Tender Summary

OUR REF NO 26250343
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40.90 Lakhs
LAST DATE 09-01-2021
Authority
Authority Name Military Engineer Services
Work Description Provn Of Drainage ( Approx 650 Mtr ) And Standby Reserve Electric Geysers And Spl Repair/Renewal Of Bldg Earthings For Certain Md/Otm Accn Including Certain Minor Works/Arboriculture At Dinjan Mil Stn
Basic Detail
Tender No C/8233/E8
Bidding Type Tender
Location
City DINJAN MIL STN
State Assam
Key Dates
Publish Date 02 Jan 2021
Submission Date 09 Jan 2021
Open Date 11 Jan 2021
Finance
Tender Value 40.90 Lakhs
Tender Fee 500
EMD 81800
Exemption Not Available
Document List
Tendernotice_1.pdf
CREDIT.pdf
BOQ_449851.xls
D624E004-28A6-46B9-90DE-12437D80FC06.html
TenderdocuF8233.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 02, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 02, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 09, 2021
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 09, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 11, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

pdf

CREDIT.pdf

xls

BOQ_449851.xls

html

D624E004-28A6-46B9-90DE-12437D80FC06.html

pdf

TenderdocuF8233.pdf

Disclaimer