Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #26249545

Supply Of Uv-Visible Spectrophotometer

Issued by Boards / Undertakings / PSU · DEPARTMENT OF CHEMISTRY, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
26 Dec 2020
0 days left
EMD
5000
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
DEPARTMENT OF CHEMISTRY → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply Of Uv-Visible Spectrophotometer , Uv-Visible Spectrophotometer , Operation: Instrument With Capabilities Like Multi Wavelength Photometric , Spectrum , Time Scan , Kinetics , Multi Component Quantitation , Dna And Protein Quantitaion . Hardware:1 . Range: 190Nm To 1100Nm 2 . Monochromator: Blazed Holographic Grating With Crenzy Turner Mountings . 3 . Spectral Bandwidth: 1Nm 4 . Wavelength Accuracy: +/-0 . 3Nm Over Entire Range5 . Wavelength Repeatability: +/- 0 . 1Nm6 . Wavelength Scanning Rate: From 2Nm/Min To 3000Nm/Min7 . Lamp Changeover: Automatic And User Selectable Lamp Changeover Between Uv To Visible Range . 8 . Light Source: Separate Deuterium And Tungsten Lamp For Uv And Vis Range . 9 . Stray Light: Less Than 0 . 02%10 . Photometric Accuracy: Minimum +/-0 . 002 Abs11 . Photometric Repeatability: +/-0 . 001Abs . 12 . Baseline Stability: Less Than 0 . 0003Abs/Hr After One Hour Of Light Source Turn On . 13 . Baseline Flatness: Less Than +/-0 . 0006 Abs After One Hour After Light Source Turn On . 14 . Noise Level: Less Than 0 . 00005Abs . 15 . Detector: Silicon Photodiode . 16 . Validation: Instrument Should Have In Built Validation Tests . Instrument Should Be Provided With At Least 4 Usb Port For Data Storage On Thumb Drive , Connectivity To Computer And Printer Directly To Instrument . Data Stored In Thumb Drive Should Be At Least In Text Format And Transferable To Ms Excel . Instrument Should Have Facility To Take Print Outs From Instrument On Printers DirectlySoftware:Software Should Able To Perform Spectrum , Kinetics And Quantitation With Normalization , Peak Pick , Point Peak , Area Calculation , Derivatives , Smoothing , Reciprocal , Square Root , Log , Abs To %T , Averaging , Interpolation , Data Set And Constant Arithmetic , Multiple Factors And User Design Equation , Display Of Standard And Sample Table Simultaneously With Calibration And Sample Curve . Software Should Be Glm And Gmp Compliant With Multilevel Security And History . Software Should Have User Design Report Formatting With Various Type Of Pre Defined Formatting Included Including Multi Page Layout .

BOQ

Name of Work: Supply of Equipments UV-Visible Spectrophotometer
Sl.No.Item DescriptionItem Code / MakeQTYUnits
11UV-Visible SpectrophotometerBI01010001010000000000000515BI0100001112
21.01Operation: Instrument with capabilities like multi wavelength photometric, spectrum, time scan, kinetics, multi component quantitation, DNA and protein quantitaion.\nHardware:\n1. Range: 190nm to 1100nm \n2. Monochromator: Blazed holographic grating with Crenzy Turner Mountings.\n3. Spectral Bandwidth: 1nm \n4. Wavelength accuracy: +/-0.3nm over entire range\n5. Wavelength repeatability: +/- 0.1nm\n6. Wavelength scanning rate: from 2nm/min to 3000nm/min\n7. Lamp Changeover: Automatic and user selectable lamp changeover between UV to visible Range.\n8. Light source: Separate Deuterium and tungsten lamp for UV and VIS range.\n9. Stray Light: less than 0.02%\n10. Photometric accuracy: Minimum +/-0.002 Abs\n11. Photometric repeatability: +/-0.001Abs.\n12. Baseline Stability: Less than 0.0003Abs/hr after one hour of light source turn ON.\n13. Baseline Flatness: less than +/-0.0006 Abs after one hour after light source turn ON.\n14. Noise level: less than 0.00005Abs.\n15. Detector: Silicon Photodiode.\n16. Validation: Instrument should have in built validation tests.\nInstrument should be provided with at least 4 USB port for data storage on thumb drive, connectivity to computer and printer directly to instrument. Data stored in thumb drive should be at least in text format and transferable to MS Excel. Instrument should have facility to take print outs from instrument on printers directly\n\nSoftware:\nSoftware should able to perform spectrum, kinetics and quantitation with normalization, peak pick, point peak, area calculation, derivatives, smoothing, reciprocal, square root, log, Abs to %T, averaging, interpolation, data set and constant arithmetic, multiple factors and user design equation, display of standard and sample table simultaneously with calibration and sample curve.\nSoftware should be GLM and GMP compliant with multilevel security and history.\nSoftware should have user design report formatting with various type of pre defined formatting included including multi page layout.\nBI01010001010000000000000515BI01000011131Nos

AI Tender Summary

OUR REF NO 26249545
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 26-12-2020
Authority
Authority Name Rashtrasant Tukadoji Maharaj Nagpur University
Work Description Supply Of Uv-Visible Spectrophotometer , Uv-Visible Spectrophotometer , Operation: Instrument With Capabilities Like Multi Wavelength Photometric , Spectrum , Time Scan , Kinetics , Multi Component Quantitation , Dna And Protein Quantitaion . Hardware:1 . Range: 190Nm To 1100Nm 2 . Monochromator: Blazed Holographic Grating With Crenzy Turner Mountings . 3 . Spectral Bandwidth: 1Nm 4 . Wavelength Accuracy: +/-0 . 3Nm Over Entire Range5 . Wavelength Repeatability: +/- 0 . 1Nm6 . Wavelength Scanning Rate: From 2Nm/Min To 3000Nm/Min7 . Lamp Changeover: Automatic And User Selectable Lamp Changeover Between Uv To Visible Range . 8 . Light Source: Separate Deuterium And Tungsten Lamp For Uv And Vis Range . 9 . Stray Light: Less Than 0 . 02%10 . Photometric Accuracy: Minimum +/-0 . 002 Abs11 . Photometric Repeatability: +/-0 . 001Abs . 12 . Baseline Stability: Less Than 0 . 0003Abs/Hr After One Hour Of Light Source Turn On . 13 . Baseline Flatness: Less Than +/-0 . 0006 Abs After One Hour After Light Source Turn On . 14 . Noise Level: Less Than 0 . 00005Abs . 15 . Detector: Silicon Photodiode . 16 . Validation: Instrument Should Have In Built Validation Tests . Instrument Should Be Provided With At Least 4 Usb Port For Data Storage On Thumb Drive , Connectivity To Computer And Printer Directly To Instrument . Data Stored In Thumb Drive Should Be At Least In Text Format And Transferable To Ms Excel . Instrument Should Have Facility To Take Print Outs From Instrument On Printers DirectlySoftware:Software Should Able To Perform Spectrum , Kinetics And Quantitation With Normalization , Peak Pick , Point Peak , Area Calculation , Derivatives , Smoothing , Reciprocal , Square Root , Log , Abs To %T , Averaging , Interpolation , Data Set And Constant Arithmetic , Multiple Factors And User Design Equation , Display Of Standard And Sample Table Simultaneously With Calibration And Sample Curve . Software Should Be Glm And Gmp Compliant With Multilevel Security And History . Software Should Have User Design Report Formatting With Various Type Of Pre Defined Formatting Included Including Multi Page Layout .
Basic Detail
Tender No Chem./ UV-VIS/01
Bidding Type Tender
Location
City DEPARTMENT OF CHEMISTRY
State Maharashtra
Key Dates
Publish Date 11 Dec 2020
Submission Date 26 Dec 2020
Open Date 28 Dec 2020
Finance
Tender Value Ref. Documents
Tender Fee 1000
EMD 5000
Exemption Not Available
Document List
Tender_UV.pdf
Tendernotice_1.pdf
BOQ_1085197.xls
E9619F7E-E57A-47F4-9790-6B780528E068.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 11, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 26, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 28, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tender_UV.pdf

pdf

Tendernotice_1.pdf

xls

BOQ_1085197.xls

html

E9619F7E-E57A-47F4-9790-6B780528E068.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders