Military Engineer Services-MES has published Periodical Services , External Internal Plastering , Repair To Flooring , Tiling , Joinery , Brick Work , Aluminium Works , Sanitary Fittings , Certain Br Works , Repair Of Dg Set , Transformer , Lt Panel , Certain Internal Em Works At Dpdo Gu. Submission Date for this Tender is 07-01-2021. Diesel Generators Tenders in GE (AF) Gurgaon Haryana. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 24-Dec-2020 | Amendment | BOQ | 31-12-2020 |
2 | 31-Dec-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 07-01-2021 |
Name of Work : PERIODICAL SERVICES, EXTERNAL/INTERNAL PLASTERING, REPAIR TO FLOORING, TILING, JOINERY, BRICK WORK, ALUMINIUM WORKS, SANITARY FITTINGS, CERTAIN B/R WORKS, REPAIR OF DG SET, TRANSFORMER, LT PANEL, CERTAIN INTERNAL E/M WORKS AT DPDO GURGAON, REPAIRS TO BRICK WORKS, FLOORING, PLUMBING, LEAKAGE/SEEPAGE, JOINERY, CERTAIN B/R WORKS AND CERTAIN INTERNAL E/M WORKS AT AF STN RAJOKRI UNDER AGE B/R (AF) RAJOKRI AND AGE E/M (AF) RAJOKRI OF GE (AF) GURGAON | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | B/R WORKS\nDemolition of cement concrete (un-reinforced) of any description & in any position not specifically provided and removal of demolished material to a distance not exceeding 50 Mtr complete all as specified and directed | 54 | Cum | |
2 | 2 | M&L for 75 mm thick cement concrete (1:4:8) type D-2 with using 40 mm graded stone aggregates) as in sub base of flooing etc complete all as specified and as directed | 560 | Sqm | |
3 | 3 | M&L for 40mm thick cement concrete type B-, 1:2:4 (20mm graded aggregate) as in flooring finished even and smooth without using extra cement complete all as specified | 200 | Sqm | |
4 | 4 | M&L for screed bed or bedding layer of mortar 20 mm thick in CM 1:6 for laying floor finishes complete all as specified and as directed. | 360 | Sqm | |
5 | 5 | M&L chequered cement concrete coloured tiles 30 cmx30 cmx25mm, set jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified and directed. | 360 | Sqm | |
6 | 6 | M&L PCC 1:2:4 type B-1 (using 20mm graded stone aggregate as in coping benching, gola and similar items all as specified and directed | 0.5 | Cum | |
7 | 7 | M&L for preparation of plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing scrapping down smoke spot moulds moss and efflorescent salts and treating oily & greasy spots and filling of holes and cracks with with suitable material like cement or plaster of paris etc and thereafter applying two coat of oil bound distemper on walls complete all as specified and as directed. | 2000 | Sqm | |
8 | 8 | All as per item No-07 above but on surfaces of ceiling. | 100 | Sqm | |
9 | 9 | Complete removal of existing treatment from external surfaces of walls, parapets, fins/ facia, chajjas by wire brushing and washing, rubbing down and stopping of surfaces and levelling/ edging the disturbed places/ edges using necessary filling compound of cement based putty to obtain smooth regular/ even finish surface using sand paper and applying One coat of Weather Exterior Emulsion paint complete all as specified and as directed. | 100 | Sqm | |
10 | 10 | M & L for providing 3mm thick wall care putty on wall before applying Oil bound Distemper and making the surface uniform all as specified and directed by Engr-in-charge. | 150 | Sqm | |
11 | 11 | M&L preparation of old painted surfaces of wood & wood based of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. | 250 | Sqm | |
12 | 12 | M&L preparation of old painted surfaces of steel of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. | 200 | Sqm | |
13 | 13 | Demolition of brick or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone works and precast concrete articles, complete all as specified and directed | 22 | Cum | |
14 | 14 | M & L brick work with sub class ‘B’ bricks old size straight or curved on plan exc 6.0 M mean radius built in cement mortar 1:6 complete all as specified and as directed. | 22 | Cum | |
15 | 15 | Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys ,scrubbing down with water etc complete all as specified and directed. | 1085 | Sqm | |
16 | 16 | M&L 15mm thick plastering in CM 1:4 on brick or concrete surfaces including rendering on fins, fascias, chajja, parapets etc and finishing the surfaces even and fair without using extra cement complete all as specified and directed | 550 | Sqm | |
17 | 17 | M&L preparation of newly plastered surfaces of wall and applying two coats of cement base paint o on walls. complete all as specified and directed. | 550 | Sqm | |
18 | 18 | M&L Rendering 15 mm thick in CM 1:6 on brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as spd and directed | 550 | Sqm | |
19 | 19 | M&L for preparation of newly plastered or unplastered/undecorated surface of wall and applying two coats of Oil Bound distemper over one coat of primer complete all as specified and directed | 550 | Sqm | |
20 | 20 | M&L rendering 10mm thick in CM 1:3 as in ceilings finished even and smooth without using extra cement complete all as specified and as directed. | 90 | Sqm | |
21 | 21 | M&L for preparation of newly plastered or unplastered/undecorated surface of Ceiling and applying two coats of Oil Bound distemper over one coat of primer complete all as specified | 90 | Sqm | |
22 | 22 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish of the premises complete all as specified and directed | 90 | Sqm | |
23 | 23 | M&L for screed bed or bedding layer of mortar 15mm thick in CM 1:6 for bedding of tiles complete all as specified and as directed. | 20 | Sqm | |
24 | 24 | M&L 10 mm thick rendering in CM 1:4 on vertical surfaces for backing of tiles complete all as specifed and directed by Engr-in-charge | 70 | Sqm | |
25 | 25 | M&L for non- skid ceramic coloured tiles 7 to 8mm thick (Square/ rectangular) area of each tile exceeding 0.11 but n.exc 0.18 Sqm, in floors/shirting etc, set and jointed in neat cement sluury and pointed in white or coloured cement to match complete all as spd and directed by Engr-In-Charge. | 20 | Sqm | |
26 | 26 | M&L Glazed ceramic coloured/ printed tiles in vertical surface of size 350x 250 x 7mm/450x 300 x 7-8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match on walls as in dado/ skirting etc complete all as specified and directed by Engr-in-Charge. | 70 | Sqm | |
27 | 27 | M&L for 25 mm thick PCC 1 :2 :4 type B-O (Using 12.50mm graded stone aggregate) as in floor complete all as specified & as directed. | 80 | Sqm | |
28 | 28 | M&L Coloured Vitrified Ceramic tiles 10 mm thick (Square/rectangular) of light Shade , polished, area of each tile not exceeding 0.36 sqm, fixed in floor etc over set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles complete all as specified and directed. | 80 | Sqm | |
29 | 29 | Dismantling of existing water tanks of steel/PVC/AC of capacity 5000 litres and S&F rotational moulded polyethylene water storage tanks 5000 ltrs capacity (cylinderical vertical with closed top) hoisted and fixed in position complete all as specified and directed. | 2 | Each | |
30 | 30 | S&Fixed in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm bore and fixed, minimum weight of float valve 210 gms complete all as specified and directed. | 2 | Each | |
31 | 31 | Taking down steel tubing & connections including cleaning for refixing serviceable pipe or removal balance pipe of 15 mm dia bore complete all as specified and as directed | 30 | RM | |
32 | 32 | Taking down steel tubing & connections including cleaning for refixing serviceable pipe or removal balance pipe of 20 mm dia bore complete all as specified and as directed | 10 | RM | |
33 | 33 | S&F medium grade galvanized steel tubing with all fittings &fixed complete to walls & ceiling or laid in floors 15 mm dia bore pipe (including in short length) complete all as specified and as directed | 30 | RM | |
34 | 34 | S&F tubes medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors 20 mm dia bore pipe (including in short length) complete all as specified and as directed | 10 | RM | |
35 | 35 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and directed. | 45 | Each | |
36 | 36 | Description same as per item No 1above but exc 1.5 Sqm but not exc 4 Sqm each complete all as specified and as directed. | 48 | Each | |
37 | 37 | Taking down shutter of any description exc 1 Sqm and n.exc 2 Sqm and removing from site. | 21 | Each Leaf | |
38 | 38 | Taking down shutter of any description n.exc 1 Sqm and removing from site. | 10 | Each Leaf | |
39 | 39 | S&F factory made 35mm thick flush shutters solid core construction with block board core and plywood face pannel commercial type on both faces complete all as specified and as directed. | 60 | Sqm | |
40 | 40 | S&F solid PVC door frame of size 50mm X47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification and drawing. Make:- Rajshri/Sintex | 140 | RM | |
41 | 41 | S&F factory made PVC shelter panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement , supplying and fixing in the frame at site as per specification & drawing as specified. Make:- Rajshri/Sintex | 48 | Sqm | |
42 | 42 | S & F 100 mm Butt hinges, medium weight cold rolled, mild steel and fixed complete all as specified and as directed\n | 96 | Each | |
43 | 43 | S&F 100 mm size but hinges type C-21 extruded aluminium alloy with galvanised mild steel hing pin, anodised and fixed, complete all as specified and as directed | 84 | Each | |
44 | 44 | S&F 200mm long aluminium anodised, barrel tower bolts of extruded section. Complete all as specified and as directed\n | 104 | Each | |
45 | 45 | S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section. Complete all as specified and as directed\n | 56 | Each | |
46 | 46 | S&F in repair 150 mm long aluminium anodised, barrel tower bolts of extruded section. Complete all as specified and as directed\n | 20 | Each | |
47 | 47 | S & F 100 mm size extruded aluminium alloy handles cast type anodised and fixed. | 56 | Each | |
48 | 48 | S & F 150 mm size extruded aluminium alloy handles fabricated type anodised and fixed. | 104 | Each | |
49 | 49 | Hacking out old broken glass ordinary quality or description from wooden or metal frames glazed with putty or fixed with beads complete all as specified and directed by Engr-in-Charge. | 5 | Sqm | |
50 | 50 | S&F sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads complete all as specified and directed by Engr-in-Charge. | 45 | Sqm | |
51 | 51 | S&F 105X60mm girth pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete as specified made out of 1.25mm thick MS Sheet complete all as specified and as directed. | 135 | RM | |
52 | 52 | M&L prepration of new Steel surfaces of any description, not otherwise descri-bed, over 10cm width or girth & applying two coats of synthetic enamel paint complete all as specified and directed | 67 | Sqm | |
53 | 53 | S&F in repair fancy type Angle stop cock with flange, 15 mm nominal bore, brass, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and directed. \n | 10 | Each | |
54 | 54 | S&Fixed in repair white vitreous China wash down water closet pan (pedestal) pattern, and trap (excluding) fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. complete all as specified and directed. | 20 | Each | |
55 | 55 | S&F in repair of plastic water closet seat covers white closed pattern with flat bottom, with mild steel chromium plated or aluminised hinging device complete all as specified and directed. | 25 | Each | |
56 | 56 | S&Fixed in repair vitreous china wash hand basin (flat back) of size 550x400mm including one number chromium plated waste fittings, 32 mm dia, brass with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, with & including 32 mm dia PVC waste pipe with connector, including cutting for and pinning in ends of brackets complete all as specified and directed. | 22 | Each | |
57 | 57 | S&F pillar taps, brass, with capston heads, fancy type chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and fly nuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed. | 22 | EACH | |
58 | 58 | S&F in repair bib taps, long body, brass, fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed. | 70 | Each | |
59 | 59 | S&F in repair PVC connection 450 mm long suitable for 15 mm GI pipe with two brass nuts & rubber washers complete all as specified and directed. | 70 | Each | |
60 | 60 | S&F in repairs PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action type with inlet ball valve and float, handle with & including bracket and PVC flush pipe 32 mm bore complete all as specified and directed | 49 | Each | |
61 | 61 | S&F in repair PVC (SWR) floor trap plain with grating having dia meter of out let 75mm including jointing with solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified & as directed. | 2 | Each | |
62 | 62 | S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 75mm bore. | 25 | RM | |
63 | 63 | S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 110 mm bore. | 45 | RM | |
64 | 64 | S&F in repair PVC (SWR) bends any radius 110mm bore. | 11 | Each | |
65 | 65 | S&F in repair PVC (SWR) bends any radius 75mm bore. | 11 | Each | |
66 | 66 | S&F in repair PVC (SWR) junction single, (single T) equal or unequal 75 mm bore complete all as specified and as directed | 9 | Each | |
67 | 67 | S&F in repair PVC (SWR) junction single, (single T) equal or unequal 110mm bore complete all as specified and as directed | 8 | Each | |
68 | 68 | S&F in repair 110mm dia PVC (SWR) pipe and single socketed in any length with rubberring joint fixed to wall. | 75 | RM | |
69 | 69 | S&F in repair door seals made of aluminium strip powder coated 20 mm wide and provided rubber/ cotton mat lining fixed with screws to door shutters up to 1 mtr width opening complete all as specified and as directed. | 20 | Each | |
70 | 70 | S & F in repair drapery rod 25 mm dia high strength aluminium rod with powder coated paint of thickness 40/60 microne of wood finish and one set of ornamental decoative finish wooden clamps all accessories complete all as specified and directed | 20 | RM | |
71 | 71 | Taking down of aluminium frame/doors/windows from site dismantling aluminium structure such as glass, rubber beading aluminium clips complete all as specified | 5 | Sqm | |
72 | 72 | S&F powder coated anodized aluminum frame for doors, windows ventilations with one or more rebates including joining cleat for fixing etc. complete all as specified. | 70 | Kg | |
73 | 73 | S&F powder coated anodized aluminum door shutters, aluminum section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing handles 2 Nos in each door,100 mm long hinges (3 Nos), anodized aluminum snap beading screws etc. complete all as specified. | 8 | Sqm | |
74 | 74 | S & F powder coated Anodised aluminium window and ventilator shutters side hung type without sash bar, aluminium sections weighing 0.55 kg/m including necessary joining, cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as hinges type B-21 100 mm long (2 nos) suitable handle 1 No Tower bolt 100 mm 1 No complete all as specified | 4 | Sqm | |
75 | 75 | M&L for 5 mm thick sheet glass ordinary quality and glazing each pane fixed with including neoprene rubber gasket in aluminium frame work complete all as specified and directed. | 5 | Sqm | |
76 | 76 | S & F 9 mm thick prelaminated particle board exterior grade in bottom panel of Aluminium door including rubber gasket, aluminium glazing clips complete all as specified and directed | 3 | Sqm | |
77 | 77 | S&F fabricated anodized aluminium grill of size 75x100mm, using 5mm dia bars fixed to frames using U/V section runners complete all as specified and as directed | 4 | Sqm | |
78 | 78 | S & F in repair Mortice lock, vertical type of brass 100 mm 4 Levers with duplicate keys complete all as specified. | 20 | Each | |
79 | 79 | S & F in repair Cast iron body door closer hydraulically regulated, designation No .1 universal type suitable for door shutters upto 851 to 1000 mm in width and of weight 35 kg complete all as specified | 10 | Each | |
80 | 80 | S & F in repair Cast iron body door closer hydraulically regulated, designation No .3 universal type suitable for door shutters upto 701 to 850 mm in width and of weight 36 to 60 kg complete all as specified | 10 | Each | |
81 | 81 | S&F in repair plain fillets , square, rectangular or triangular in section clean sawn secured with nails or brads II nd class Hard Wood sectional area exc 13 Sqcm & n.exc 25 sqcm all as specified | 10 | RM | |
82 | 82 | M & L preparing new wood or wood based surfaces of any description N.exc 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. | 1 | X RM | |
83 | 83 | S&F Continuous (piano) hinges, mild steel bright finish electrogalvanised 20mm width of flap complete all as specified. | 15 | RM | |
84 | 84 | S&F in repair 18/19 mm thick prelaminated particle board interior grade prelaminated both side with decorative choice laminations and other side balancing white lamination fixed with screws to timber frame work . | 5 | Sqm | |
85 | 85 | S&F Hasp & staple safety type aluminium anodized with mild steel hing pin incl bolt to hing plate and fixed with screws 100mm size complete all as specified | 8 | Each | |
86 | 86 | S&F as in repair 600x450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as directed. | 5 | Each | |
87 | 87 | S & F in repair Bottle trap of PTMT having minimum water seal of 25mm. (Minimum weight 32mm-260gms/40mm-270 gms) complete all as specified and as directed | 5 | Each | |
88 | 88 | S&F as in repair aluminium anodised tubular towel rail 20mm dia, type D, 60cm long between flanges complete all as directed. | 5 | Each | |
89 | 89 | S&F vitreous china bowl urinal flat back of size 465 x 355x 265 mm, white including grating and union for discharge pipe, including waste pipe and including fixing plugs beading urinal against wall in CM 1:2, securing urinal to plugs with brass screws 60 mm long, pointing around urinal in white cement specified and directed. | 4 | Each | |
90 | 90 | S&F in repair 610 mm long PVC waste pipe flexible type 25 mm dia suitable for couplings 32 mm & 40 mm dia complete all as specified and as directed | 40 | Each | |
91 | 91 | Dismantling ceiling board (fiber, pulp insulation) or insulation board/slabs etc including grid work/wooden or aluminium frame works, cover fillet etc Complete all as specified and directed. | 25 | Sqm | |
92 | 92 | M & L for clip in type armed strong metallic powder coated ceiling with GI framework made up of standard Tee , angle or any other section as in grid type ceiling framework as approved by GE . Ceiling shall be hanged to roof trusses / purlin rafters with the help of GI wire not less than 4mm dia at an interval n exc 1m , the size of the metallic powder coated ceiling tiles 600mm x 600mmx 0.5mm complete all as specified | 25 | sqm | |
93 | 93 | M&L for machine presssd pre-cast coloured concrete interlocking paver block any shape confirming to IS-15658-2006 of 60mm thick , M-35 Grade with grey cement and pigment as approved complete all as specified and as directed | 400 | Sqm | |
94 | 94 | M & L sand filling under interlocking tiles for cushioning etc as complete and as directed | 10 | Cum | |
95 | 95 | Taking down existing unserviceable water proofing treatment from roof slab including plaster and cleaning the roof slab by wire brush and removing the debries and WPT felt beyond the premises of MD land. | 550 | Sqm | |
96 | 96 | M&L for 15 mm thick plaster in CM (1:3) mixed with water proofing compound on roof slabs finished even and smooth without using extra cement after cleaning of roof surfaces with wire brushes complete all as specified and directed by Engr-in-Charge. Notes : WPC shall be measured and paid seperately \n | 550 | Sqm | |
97 | 97 | Supply only Water Proofing Compound | 50 | KG | |
98 | 98 | M & L for applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg/Sqm including cleaning surface complete as all specified and as directed | 550 | Sqm | |
99 | 99 | M&L for 3mm thick APP modified prefabricated membrane in five layers & weight not less than 3.6 Kg/Sqm water proof membrane reinforced with non-wooven polyster without aluminium paint over top surface of water proofing membrane with 10cm longitudinal and horizontaling over lapping and joints finally thermo-fused with LPG flames laid over a tack coat of industrial coat of primer as per manufacturer's instructions of APP modified membrane sheet complete all as spd and directed by Engr-in-Charge. | 550 | Sqm | |
100 | 100 | Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings Complete all as specified and directed. | 515 | Sqm | |
101 | 101 | S & F Pre -Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ clading to wall fixed with self tapping screws complete all as specified | 515 | Sqm | |
102 | 102 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed | 9.4 | Qtls | |
103 | 103 | S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed | 850 | Kg | |
104 | 104 | S & F Plates ( plain or chequered square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed | 60 | Kg | |
105 | 105 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay) heavy for large gates, hook and pintle hinges large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 | 45 | Kg | |
106 | 106 | S&F factory made 35mm thick 2nd class hardwood glazed and skelton door shutters, open rebated and prepared to receive glass, gauze, (without sash bars) edges for framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part-1 section 8 clause 8.24 (a) fitted to chowkats complete all as specified and as directed. | 40 | Sqm | |
107 | 107 | S & F 75 mm Butt hinges, medium weight cold rolled, mild steel and fixed complete all as specified and as directed\n | 30 | Each | |
108 | 108 | S&F 250mm long aluminium alloy anodised sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast sections or cast aluminium alloy complete all as specified and as directed. | 10 | Each | |
109 | 109 | Dismantling boarding of any description , fixed in any position with nails complete all as specified and as directed. | 10 | Sqm | |
110 | 110 | S&F 25mm thick flush shutters, as in cupboard , solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed | 10 | Sqm | |
111 | 111 | S&F 18 to 19mm thick block board grade 2 quality interior grade decorative type with decorative face veneer on one face fixed with screws to timber framework as in shelves, drawers etc complete all as specified and as directed. | 10 | Sqm | |
112 | 112 | M&L preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed. | 80 | Sqm | |
113 | 113 | S&F 125X60mm girth pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges lock strike plate etc complete as specified made out of 1.25mm thick MS Sheet complete all as specified and as directed. | 75 | RM | |
114 | 114 | S&F window or ventilators section of frame 72x55mm fixed to wall or concrete surface with rowl plugs made of galvanised steel powder coated and section of shutter 47x20mm mulion section 72x50mm (Based steel as per IS 513 "D" quality galanised as per IS 277 with zinc of 120 gms/sqm) glazed or gauged and wire gauge shutter prepare to receive wire mesh to the shutter (Double door shutter) with total coated thickness of 0.6mm including grills/guard bars made of square bars powder coated fixed to window frame with screws including necessary fittings and all builders hardware such as handles, tower bolts and stays etc complete all as specified and as directed. Make : NCL type-4000 Series (Note : Glass and wiremesh shall be measured and paid separately under respective items) | 72 | Sqm | |
115 | 115 | S&F galvanised stainless steel wire cloth, 0.46mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified and as directed | 45 | Sqm | |
116 | 116 | S&F in repair fancy type Angle stop cock with flange, 15 mm nominal bore, brass, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and directed. \n | 50 | Each | |
117 | 117 | E/M WORKS\nDG Set\nCarry out 'B' check from authorised rep or service engineer from the manufacturer of DG set of 200 KVA,capacity Make : Cummins \n(including the cost of the following spares all as per OEM instructions and directed) :-\n(a) S & F in repair lubrication oil filter\n(b) S & F in repair by pass filter \n(c) Checking of hydraulic governer \n(d) Checking and toping up of coolant\n(e) S & F in repair fuel filter\n(f) S & F in repair air cleaner element . \n(g) Cleaning radiator complete set\n\n | 1 | Each \nJob | |
118 | 118 | S&F Solenoied switch sutaible for 200 KVA DG Set complete All as specified & directed by engr-in-charge\n | 1 | Each | |
119 | 119 | S&F of Ring gear of Flywheel suitable for DG set up to 200 KVA complete All as specified & directed by engr-in-charge | 2 | Each | |
120 | 120 | Supply and fixing in replacement of AVR S/F VARIABLE SPEED DCDG suitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage suitable for DG set of 200 KVA complete all as specified and directed by Engineer -in-charge. | 1 | Each | |
121 | 121 | Disconnected and opening of self starter assemlly 12/24 volt for repair from DG set up to 200 KVA & repair unserveceable part of self starter suitable size as required on site complete all as specified and directed.\nNote :- Rate are deemed tobe include all worn out part including gear & winding complete all as specified | 1 | Each | |
122 | 122 | Supply only the following items of DG Set of various capacity :- | |||
123 | 122.01 | Battery terminal, lug, bolts type suitable for heavy duty battery. | 3 | Set of 2 | |
124 | 122.02 | Battery leads for copper conductor multiwired 70 Sqmm Single Core. | 6 | RM | |
125 | 122.03 | Hinges for DG set door of any size, any type as required on site. | 8 | Each | |
126 | 123 | Dismantling existing U/S battery charger & S/F of SMPS type battery charger suitable for 12 V DC with auto cut off from trickle to boost alongwith AC lead to charge the battery when DG Set is not in use complete all as specified & directed by Engineer Incharge. | 1 | Each | |
127 | 124 | S&F V belt for fan pulley (set of 2Nos) for DG set upto 200 KVA DG Set complete all as specified. | 2 | set | |
128 | 125 | S&F V belt for alternator and water pump assembly for DG set upto 200 KVA complete all as specified. | 1 | Each | |
129 | 126 | S&F Fuel hose pipe from fuel filter to fuel pump for DG set upto 200 KVA, complete all as specified. | 1 | Each | |
130 | 127 | S&F Fuel pipe from fuel tank to fuel filter for DG set upto 200 KVA, complete all as specified. | 4 | set | |
131 | 128 | Material & labour for carrying out complete overhauling / servicing of DG set (200 KVA) panel / AMF panel / control panel, including checking and rewiring faulty electrical circuit using 1.5 sqmm FRLS copper conductor, for DG Set of any type / make / capacity, making all electric connections and testing for smooth operation, complete all as directed. | 1 | Each | |
132 | 129 | Supply and fixing of 'under/over voltage relay, 3 phase, 415 volts', for DG sets of capacity upto 200 KVA complete all as specified and directed by engineer-in-charge. | 3 | Each | |
133 | 130 | Supply and fixing in replacement of Lead acid maintenance free Battry 12 Volts 180AH of existing type & size suitable for DG Sets . Make : EXIDE/Amoron including initial charging. | 2 | Each | |
134 | 131 | Labour for attending of any breakdown of standby supply in any location ,whenever required round the clock ,rectify the fault and restore the standby supply within three hour after receipt of complaint of any nature i.e. Engine, alternator,control panel,AMF panel etc . \nNote -(i) The cost of replaced spare parts will be paid and measured seperatly. (ii) If complaint is not attended by contractor with in five hour the penality of Rs 500 / per hour to be imposed and amount of penality will be deducted from RAR. (iii) The cost of transportation (to and fro) for all kind of necessary equipment / T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically ,so contractor to specify the telephone no who will receive the complaint round the clock. | 12 | Each | |
135 | 132 | Material & labour for opening / taking out of injector of DG set of any type/make and capacity 200 KVA disconnection and opening of fuel injector assembly, carrying complete overhauling/servicing fuel injection system with including replacement of injector repair kit ,including calibration of injector, checking of pressure complete for each injector and re-assembling the same, fitted with DG set properly in original location, checking the allignment, making proper fuel connection, testing for smooth opreatio complete all as directed. | 1 | Each job | |
136 | 133 | S&F in replacement of unsv thermostat with new thermostat alongwith complete assy for DG set connection testing complete all as specified and directed. | 1 | Each | |
137 | 134 | Material & labour for complete overhauling,servicing of turbo charger, opening /taking out of turbo charger of DG set of 200KVA capacity ,disconnection of air supply connection pipe etc, including replacement of turbo charger repair kit, calibration/ testing of turbo charger system complete and re-assembling the same ,fitted with DG set properly in original position, checking the allignment, making proper all connection, testing for smooth opreation from authorised rep or service engineer from the manufacturer complete all as directed. | 1 | Each job | |
138 | 135 | M&L for capacity 200 KVA complete descaling of cooling system by radiwash with two times circulation of radiwash by means of running of engine & cleaning of fan blades, crankcase breather, radiator and its fins by means of high pressure air or water. | 1 | Each job | |
139 | 136 | Transformer\nM&L for Dehydration including filtration and cleaning of Transformer oil by dehydrating machine incl testing of sample before and after dehydration and filtration and replacement of silica gel all as specified and directed\nNOTE:- Contractor has to arrange the dehydration machine and testing kit without any extra cost to the dept. Test report to be submitted after completion of job. (Transformer 415 KVA) | 360 | Ltr | |
140 | 137 | Supply & Filling /pouring of up to the appropriate level Transformer oil of low viscosity having dielectric strength not less than 60 KV complete all as specified and as directed :- 82Ltr\nNOTE:- Dielectric strength test shall be carried out at site before poring/filling in transformers in the presence of Engr-in-Charge on the site\n | 82 | Ltr | |
141 | 138 | Comprehensive maintenance of transformer by isolating ,disconnecting of input/output ,supply cable, opening of top of transformer, detecting of fault ,u/s component, cleaning of serviceable parts/ component ,including replacement of worn out spare parts, finding of oil leakage & sealing it by oil seal or gas welding etc if any all as specified and directed. (Transformer 415 KVA) | 1 | Each | |
142 | 139 | Taking out VCB trolley from HT control panel 11 KV 3 phase 800 Amp , Breaking capacity 20kA (Make :- crompton greaves) and cleaning the trolley with CRC removing all dust , carbon etc greasing the mechanical parts gears ,lever charging male female contacts and spring holders all as specified and as directed. | 1 | Each | |
143 | 140 | Material and labour for sevicing of VCB panel & calibration of numerical relay as per existing load for earth fault , over current and short circuit ,including setting the relay on required electric load and testing on earth fault and short circuit and over load with the help of relay testing kit complete in all respect all as specified and as directed. | 1 | Each | |
144 | 141 | Taking down defective unserviceable LT bush porcelain insulator and supply and fix news LT bush porcelain insulator with oil seal for transformer outdoor of 415KVA all as specified and directed | 4 | Each | |
145 | 142 | Taking down defective unserviceable HT bush porcelain insulator and supply and fix news HT bush porcelain insulator for transformer outdoor of 415 KVA all as specified and directed | 3 | Each | |
146 | 143 | S&F in transformer breathers sillica gel (orange) for effective beratheing & to protect transformer oil from moiture Complete all as specified & directed by Engr-in-Charge | 8 | KG | |
147 | 144 | Technician for attending of any breakdown of HT/LT supply due to fault in VCB or transformer, whenever required round the clock ,rectify the fault and restore the standby supply within four five after receipt of complaint of any nature. \nNote -(i) The cost of replaced spare parts will be paid and measured seperatly.\n(ii) If complaint is not attended by contractor with in five hour the penality of Rs 500 / per hour to be imposed and amount of penality will be deducted from RAR.\n(iii) The cost of transportation (to and fro) for all kind of necessary equipment / T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically ,so contractor to specify the telephone no who will receive the complaint round the clock. | 12 | Each job | |
148 | 145 | Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 185 Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed. | 50 | RM | |
149 | 146 | Same as item No 145 but size 3.5 core X 95 sqmm | 50 | RM | |
150 | 147 | Comprehensive maintenance of Main LT panel & cubical type indoor automatic capacitor panel by isolating ,disconnecting of input/output ,supply cable, detecting of fault ,u/s component in panel ,cleaning of serviceable parts/ component ,including replacement of worn out switches LED indicator, spare parts, Welding of Panel door & replacement of Door lock, replacement of old wiring with 2.5 sqmm to 6 sqmm etc, if required all as specified and directed. Replacement of Capacitor of verious size will be measured & paid separately | 2 | Each | |
151 | 148 | Internal E/M\nTaking down existing 11 watt 2 pin CFL ceiling fittings from the existing positions by disconnecting elect connections from ground floor complete all as specified and directed by Engr-in-charge including all materials required at site (Ground Floor - 60 Nos) | 70 | Each | |
152 | 149 | Supply and fixing LED surface light (Square) SSk-SDS-30 W-N, size 300X300X40 mm input power 30watt Lumens> 2400, housing pressure die-cast aluminium\nMake: Syska or Equivalent model in Bajaj/Havells/Cromptons | 70 | Each | |
153 | 150 | Taking down unsv banned CFL post top fitting/Flood light from the existing positions by disconnecting elect connections complete all as specified and directed by Engr-in-charge including all materials required at site -12 Nos) | 12 | Each | |
154 | 151 | Supply and fixing in existing position LED , Post top fittings powder coated aluminium, IP 65 protection cat part no- PGR0201009, catalogue reference PCGLP01400, 40 Watt , CCT 5700 k , HSN code 9405\nMake: Polycab or equivalent make in Bajaj/Havelles/CG \n Location: in/out gate | 4 | Each | |
155 | 152 | Supply and fixing in existing position LED , Post top fittings powder coated aluminium, IP 65 protection cat part no- PGR0201007, catalogue reference PCGLP01250, 25 Watt , CCT 5700 k , HSN code 9405\nMake: Polycab or equivalent make in Bajaj/Havelles/CG\nLocation: Front Boundary wall | 6 | Each | |
156 | 153 | Supply and fixing in existing position LED FLAT flood light powder coated aluminium, IP 65 protection cat part no- SSK-BLS-F-150W, Wattage-150 ,input voltage AC 90-300V ingress protection IP 65 , power factor> 0.9 ,housing pressure die cast aluminium \nMake: Syska or Equivalent model in Bajaj/Havells/Cromptons\nLocation: Front side of bldgs | 2 | Each | |
157 | 154 | Supply and fixing in existing position LED street lights-SLF-CF series cat part no- SSK-SLF-CF-120W, Wattage-120W IP 65 protction .\nMake: Syska or Equivalent model in Bajaj/Havells/Cromptons\nLocation: Backside of bldgs | 2 | Each | |
158 | 155 | Supply & fixing LED deep down light (round) series cat part no- SSk-DLC-6"- 20 W, wattage-20 watt.\nMake: Syska or Equivalent model in Bajaj/Havells/Cromptons\nLocation: Main entry porch | 8 | Each | |
159 | 156 | Supply & fixing surface mounted LED bulk head luminaire with ABs body & polycarbonate diffuser product code 0101316, wattage 10 watt HSN code 9405 .\nMake: Polycab or Equivalent model in Bajaj/Havells/Cromptons\nLocation: Both side passage & main bldgs | 20 | Each | |
160 | 157 | S&F service bracket made of GI-pipe light grade fitting 1.2 m in length and fixed on wall including necessary MS clamps nuts, bolts etc complete, all fixing materials included in the unit rate. | 4 | Each | |
161 | 158 | Taking down hanging/unsv CFL type wall lights , mirror lights and ceiling lights by disconnecting electrical connections complete including all the materials required for the purpose at site from VIP Guest rooms on 2nd floor complete all as specified and directed by Engr-in-charge | 98 | Each | |
162 | 159 | Supply and fixing in existing position LED T-5 Batten cat part no- SSK-T5-SQ2201-AL input power-22W, size 22X36X1260(L)mm, IP-20 aluminium housing, Lumens>1900 .\nMake: Syska or equivalent in Philips/Wipro/CG\nLocation: VIP Bed Rooms\n | 56 | Each | |
163 | 160 | Supply and fixing in existing position LED T-5 Batten cat part no- SSK-T5-SQ1201, input power-12W, size 22X36X600 L)mm, IP-20 aluminium housing, Lumens>1200 .\nMake: Syska or equivalent in Philips/Wipro/CG \nLocation: VIP Guest RoomToilet | 14 | Each | |
164 | 161 | Supply and fixing in existing position LED surface light(Square) cat part no- SSK-SDS-18W-N input power-18W, size 225X225X40 L)mm, IP-20 pressure diecast aluminium housing, Lumens>1440 .\nMake: Syska or equivalent or equivalent in Philips/Wipro/CG\nLocation: VIP Guest RoomToilet\n | 14 | Each | |
165 | 162 | Supply and fixing in existing position LED surface light(Square) cat part no- SSK-SDS-12W-N input power-12W, size 172X172X40 L)mm, IP-20 pressure diecast aluminium housing, Lumens>900 .\nMake: Syska or equivalent or equivalent in Philips/Wipro/CG\nLocation: VIP Guest Room balcony | 14 | Each | |
166 | 163 | Taking down old existing 18 W CFL type 2'x2' panel by disconnecting elect connections complete all as specified and directed by Engr-in-charge including all materials required at site -F/F Director office) | 25 | Each | |
167 | 164 | Supply and fixing LED Backlite panel (2x2) cat part no- SSK-TVP-6060-36 W , size 600X600X50 (H) mm, Lumens>3700, IP-20, sheet aluminium housing complete with all fixing arrrangements/materials required at site including making good of distrubed surface for matching with distrubed existing surface inculding POP/Putty and white wash as per direction by Engr-in-Charge.\nMake: Syska or equivalent in Philips/Wipro/CG \n Location: Director office F/F | 25 | Each | |
168 | 165 | Taking down CFL fitting 11 watt from the ceiling complete all as specified and directed by Engr-in-charge\n(Porch and passage area G/F) | 25 | Each | |
169 | 166 | Supply and fixing in existing position LED surface light(Square) cat part no- SSK-SDS-30W-N input power-30W, size3002X300X40 L)mm, IP-20 pressure diecast aluminium housing, Lumens>900 .\nMake: Syska or equivalent in Philips/Wipro/CG \nLocation: VIP Guest Room balcony\n\nNote: All the distrubed surface shall be made as good as existing including all materials required at site: i.e POP/Putty/White wash /Distemper and no extra amount will be paid on this account. | 25 | Each | |
170 | 167 | Taking downexisting Fluorescent tube light fittings 1X 36 w from Ceiling area of stilt area by disconnecting electric connection carefully including all T&P requitred at site | 85 | Each | |
171 | 168 | Ditto as per item no 167 above but CFL type fittings 2 pins 11 w complete all as spceified | 20 | Each | |
172 | 169 | Supply and fixing in LED T-8 batten fitting Cat aprt no SSK-TL-22W-F, input power 22 w, size 26.5X1200mm, input Volatage AC 90 to 300V , Lumens>2200, Extruded aluminium housing.\nMake: Syska or Equivalent model in Bajaj/Havells/Cromptons | 85 | Each | |
173 | 170 | Supply and fixing LED surface light Square type Cat part No-SSK-SDS-22W-N, size 225X40MM Lumens>2400, Preesure die cast aluminium\nMake: Syska or Equivalent model in Bajaj/Havells/CG\n | 20 | Each | |
174 | 171 | Taking down carefully copper/aluminium point wiring light ,fan, socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. Complete all as specified and directed. | 430 | Point | |
175 | 172 | Taking down old unserviceable main switch/DBs/mcb DBs with MCB including making good the disturbed surface complete as directed | 40 | Each | |
176 | 173 | Taking down sub main wiring of any size complete all as specified and directed. | 1140 | RM | |
177 | 174 | M&L for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawn through in and including PVC conduit size of not less than 20mm concecled in wall / surface including provn of pressed steel terminal box of suitable size with 3mm thick plastic laminated sheet cover for mounting switch, socket and regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm all as specified and directed. | |||
178 | 174.01 | One light point controlled by one switch one way | 210 | Point | |
179 | 174.02 | One celling/exhaust fan point controlled by one switch one way | 50 | Point | |
180 | 174.03 | One socket out let 5 Amps 5 pin on independent board | 40 | Point | |
181 | 174.04 | One socket outlet 5 Amps 5 Pin on same board with other switches | 20 | Point | |
182 | 174.05 | One bell/buzzer point controlled by one bell push on independent board | 20 | Point | |
183 | 175 | All as per item No 174 here in before but with cable size 2.5 Sq mm for one 3/5 pin 15 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 1.5 sqmm all as specified and directed. | 90 | Point | |
184 | 176 | S&F in replacement of switch piano, flush type, 5 amps, single pole, one way \n | 300 | Each | |
185 | 177 | S&F in replacement of socket outlet 2in1, 3 pin 5 Amps flush type | 60 | Each | |
186 | 178 | S&F in replacement of socket outlet 2in1, 6 pin 15/5 Amps flush type | 60 | Each | |
187 | 179 | S&F in replacement of switch piano, flush type, 15 amps, single pole, one way | 20 | Each | |
188 | 180 | S&F in replacement of ceiling rose surface bakelite two to three terminals. | 80 | Each | |
189 | 181 | S&F in replacement of bell push , 5 amps, single pole, one way. | 20 | Each | |
190 | 182 | S&F in replacement of call bell, Ding dong type, 230 volts AC single pole complete all as directed. | 35 | Each | |
191 | 183 | S&F in replacement of ceiling fan regulator stepped electronic type 300 watt rating all as directed. | 70 | Each | |
192 | 184 | S&F in replacement of modular switches 6 amps single pole one way | 70 | Each | |
193 | 185 | S&F in replacement of modular switches 16 A single pole one way \n | 60 | Each | |
194 | 186 | S&F in replacement of modular socketes out let 6 amps 5 pin \n | 65 | Each | |
195 | 187 | S&F in replacement of modular socket out let 6-16 A 3 pin combined shuttered \n | 60 | Each | |
196 | 188 | S&F in replacement of modular white cover plate with frame 3 modular \n | 40 | Each | |
197 | 189 | S&F in replacement of Flush metal boxes 3 modular | 10 | Each | |
198 | 190 | S&F in replacement of modular white cover plate with frame 6 modular \n | 40 | Each | |
199 | 191 | S&F in replacement of Flush metal boxes 6 modular. | 10 | Each | |
200 | 192 | S&F in replacement of modular white cover plate with frame 8 modular \n | 10 | Each | |
201 | 193 | S&F in replacement of Flush metal boxes 8 modular. | 10 | Each | |
202 | 194 | S&F in replacement of MCB distribution board vertical triple pole and neutral 6 way factory made sheet steel, phosphates, powder painted with 100 Amps rated busbar, 415 volts, neutral link, earth bar and Din rail double door complete including taking down/dismantling of old unserviceable one all as specified. MCCCB-100 A, MCC DP63 Amp, MCB SP 32 A | 6 | Each | |
203 | 195 | M/L for Sub main wiring with 2 Run of 4 Sqmm cable and one run of 2.5 sqmm PVC insulated, unsheathed FR cable of multistranded copper conductors 1100 volt grade IS- 694 marked drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories concealed on wall and surface on ceiling complete all as specified and directed by Engineer in charge. | 240 | RM | |
204 | 196 | ditto but 2x2.5 sqmm and 1x1.5 sqmm. | 60 | RM | |
205 | 197 | ditto but 2x6 sqmm and 1x 4.0 sqmm. | 120 | RM | |
206 | 198 | ditto but 2x10 sqmm and 1x6.0 sqmm. | 90 | RM | |
207 | 199 | S&F in replacement of sheet metal enclosure with socket plug top and MCB single pole and neutral with two pin and earth plug with one SP MCB 10 Amp 240 volt complete all as directed. | 40 | Each | |
208 | 200 | M&L Earthing complete with galvanize steel earth plate 60 cm x 60 cm x 6.0mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr filled around with layer of charcoal dust and salt and connected to GI earth strip size of 25x4 mm by means of bolt nut and cheek nuts and washers of galvanized iron or steel and thimble and other ends of the earth strip connected to main switch board and protected by galvanized iron pipe light grade 40 mm bore and watering pipe 20mm dia light grade with funnel and wire mesh pcc 1:3:6 in chambers RCC 1:2:4 in pit cover reinforecd with 8 mm dia deformed bars 15 cm center both ways all as directed by Engr-in-charge. | 3 | Each Set | |
209 | 201 | S&F in replacement of geyser assembly suitable to fix thermostate , heating element as of the existing model & size including all clamps with bolts and nuts etc . | 2 | Each | |
210 | 202 | S&F in replacement of heating element 2000 watt capacity triangular type complete . | 5 | Each | |
211 | 203 | S&F in replacement of heating element 1500 watt capacity triangular type complete . | 5 | Each | |
212 | 204 | S&F in replacement of heating element 1500 watt capacity circular type complete . | 5 | Each | |
213 | 205 | S&F in replacement of thermostate suitable for storage type water heater complete . | 3 | Each | |
214 | 206 | Supply and fix stainless steel tank for 25 ltr storage type water heater complete . | 5 | Each | |
215 | 207 | Supply and fix Copper tank for 25 ltr storage type water heater complete . | 1 | Each | |
216 | 208 | Supply and fix indication lamp round type (Red colour) complete . | 5 | Each | |
217 | 209 | Supply and fix indication lamp round type (green colour) complete . | 5 | Each | |
218 | 210 | S&F in replacement of MCB SPN 63 Amps, 10 KA,240V, 50Hz, 'B' Series complete all as specified and as directed. | 4 | Each | |
219 | 211 | S&F in replacement of Casing capping double lock type supper quality size 15 mm width ISI marked with fixing accessories complete all as specified and directed. | 20 | RM | |
220 | 212 | S&F in replacement of rigid non metalic PVC medium grade conduit of 15 mm bore including boxes, tees,bend and fixing accessories such as copper,lock nut, saddles,pipe huck etc complete all as specified and directed by Engineer in Charge. | 40 | RM | |
221 | 213 | ditto but for 20 mm bore. | 20 | RM | |
222 | 214 | S&F in replacement of flexible conduit of size 25 mm complete all as specified and directed. | 20 | RM | |
223 | 215 | S&F in replacement of in replacement of of PVC insulated unsheathed cable, single core multi stranded copper conductor, 1100 volts for the following cross sectional area: | |||
224 | 215.01 | 1.5 Sqmm | 90 | RM | |
225 | 215.02 | 2.5 Sqmm | 90 | RM | |
226 | 216 | S&F in replacement of PVC gang box suitable for one switch and socket 5 Amps complete with screw and necessary arrangement complete all as specified and directed. | 25 | Each | |
227 | 217 | ditto but suitable for one switch and socket 15 Amps | 30 | Each | |
228 | 218 | FAN\nM&L for rewinding of following fans with same gauge of super enameled copper wire complete varnishing ,baking ,connecting properly with sleeves assembling the same including replacement of unserviceable shackle and clamps with nots /bolts/washer /split pin and blade screw s etc testing , complete all as specified and directed. NOTE: (i) Spare parts like bearing,capacitor,bushes if required will be measured and paid separately. (ii) The rates shall be deemed to include dismantling of fan and reassembling after repair /replacement of worn out parts. | |||
229 | 218.01 | Ceiling fan 1200 mm sweep | 50 | Each | |
230 | 218.02 | Wall mounted fans 400 mm sweep | 5 | Each | |
231 | 218.03 | Exaust Fan 300 mm Sweep | 15 | Each | |
232 | 219 | Supply and fix in repair ball bearing suitable for the following fans : Make :-NBC/SKF/Tata | |||
233 | 219.01 | Ceiling fan 1200 mm sweep | 50 | Each | |
234 | 219.02 | Wall mounted fan 400 mm sweep | 5 | Each | |
235 | 219.03 | Exaust Fan 300 mm Sweep | 15 | Each | |
236 | 220 | Supply and fix in repair capacitor 2.5 mfd,400 volt ,50 hz all as specified and as directed.Make : Tibcon | 50 | Each | |
237 | 221 | Supply and fix in repair capacitor 4 mfd,400 volt ,50 hz all as specified and as directed Make : Tibcon | 50 | Each | |
238 | 222 | Supply and fix in repair plastic body Exaust fan of 300 mm size with louver complete all as specified & directed by Engr-in-Charge | 15 | Each | |
239 | 223 | Taking down old existing light fitting of any type complete all as specified and directed. | 80 | Each | |
240 | 224 | S&F in replacement of modular white cover plate with frame 12 modular \n | 20 | Each | |
241 | 225 | S&F in replacement of MCB distribution board vertical triple pole and neutral 8 way factory made sheet steel, phosphates, powder painted with 100 Amps rated busbar, 415 volts, neutral link, earth bar and Din rail double door complete including taking down/dismantling of old unserviceable one all as specified and directed | 2 | Each | |
242 | 226 | S&F in replacement of MCB distribution board triple pole and neutral 4 way factory made sheet steel, phosphates, powder painted with 200 Amps rated busbar, 415 volts, neutral link, earth bar and Din rail double door complete including taking down/dismantling of old unserviceable one all as specified and directed. | 4 | Each | |
243 | 227 | S&F in replacement of MCB distribution board single pole and neutral 8 way factory made sheet steel, phosphates, powder painted with 100 Amps rated busbar, 240 volts, neutral link, earth bar and Din rail double door complete including taking down/dismantling of old unserviceable one all as specified and directed. | 4 | Each | |
244 | 228 | S&F in replacement of MCB distribution board single pole and neutral 12 way factory made sheet steel, phosphates, powder painted with 100 Amps rated busbar, 240 volts, neutral link, earth bar and Din rail double door complete including taking down/dismantling of old unserviceable one all as specified and directed. | 4 | Each | |
245 | 229 | S&F in replacement of MCCB 100 A ,3 pole ,16 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. Make: Legrand/Siemns/ABB/Schneider | 1 | Each | |
246 | 230 | S&F in replacement of MCB SPN 63 Amps, 10 KA,240V, 50Hz, 'B' Series complete all as specified and as directed. | 6 | Each | |
247 | 231 | S&F in replacement of MCB SPN 6-32 Amps, 10 KA,240V, 50Hz, 'B' Series complete all as specified and as directed. | 40 | Each | |
248 | 232 | S&F in replacement of Casing capping double lock type supper quality size 15 mm width ISI marked with fixing accessories complete all as specified and directed. | 40 | RM | |
249 | 233 | S&F in replacement of rigid non metalic PVC medium grade conduit of 15 mm bore including boxes, tees,bend and fixing accessories such as copper,lock nut, saddles,pipe huck etc complete all as specified and directed by Engineer in Charge. | 100 | RM | |
250 | 234 | ditto but for 20 mm bore. | 50 | RM | |
251 | 235 | S&F in replacement of flexible conduit of size 25 mm complete all as specified and directed. | 50 | RM | |
252 | 236 | Supply and fix LED light Batten Fitting 1x18 watt fitting including 1x18 watt LED tube connecting with twin core copper conductor all as specified and as directed .Make :- Phillips/ Bajaj/CG | 60 | Each | |
253 | 237 | S&F in replacement of CFL bulb with LED Bulbs B-22 Base- Royale series 8 Watt complete all as specified and as directed. Make : CG, Ordering code no. LED12WDF-CDL-BI or equivalent in Syska,Philips. | 50 | Each | |
254 | 238 | S&F in replacement of Recess mounted light with LED 36 Watt energy saving recess mounted luminaire suitable for 600mm x 600mm Modular/POP/Gypsum ceiling complete all as specified and as directed. Make : Crompton Cat Part No.LCTLRN-36-CDL or equivalent in Wipro,Philips. | 10 | Each | |
255 | 239 | Supply and Fixing integrated LED bulk head luminaire comprising of pressure die cast housing ,acrylic diffuser & frame with IP65 Protection .complete all as specified and as directed . Cat Part No. LBHN-10-CDL make of CG or its equivalent in Wipro/Phillips\nNote : Any reducer to suit the manufacturer mounting dia for fixing of fitting to existing bracket shall be deemed to be included in the rates quoted by the Contractor. | 10 | Each | |
256 | 240 | S&F in replacement of in replacement of of PVC insulated unsheathed cable, single core multi stranded copper conductor, 1100 volts for the following cross sectional area: | |||
257 | 240.01 | 1.5 Sqmm | 180 | RM | |
258 | 240.02 | 2.5 Sqmm | 180 | RM | |
259 | 240.03 | 4 Sqmm | 90 | RM | |
260 | 241 | S&F in replacement of PVC gang box suitable for one switch and socket 5 Amps complete with screw and necessary arrangement complete all as specified and directed. | 10 | Each | |
261 | 242 | ditto but suitable for one switch and socket 15 Amps | 10 | Each | |
262 | 243 | S & F in replacement of Copper Cable lugs/Thimbles upto size 10 sqmm complete all as specified. | 10 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy