Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Disconnecting electrical connections, taking down carefully old unserviceable indoor and out door unit of split AC/winodw type AC of 1.5/2TR/4,1TR at any height and location as directed and depositing to MES store yard. | 308 | Each | |
2 | 2 | Taking down and Dismentling submain wiring of any description complete. | 200 | RM | |
3 | 3 | Fixing only and commissioning and testing of split type wall mounted Air conditioner of capacity 1.5/2TR single phase,suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit , complete including taking down old Split AC and depositing in MES Store yard with following works :-\n(a) Making good the disturbed surface to match the existing surface after plugging the hole etc.\n(b) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wallas per Manufacture's instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 1.5 TR/2TR AC complete all as specified and directed. (c) suitable size electrical cable required to connect out door unit and indoor unit to voltage stablizer inclusive in above rate.\nNote 1. :- Half yearly complete servicing of ACs upto 02 Years (Checking refrigerent pressure, Loose Connection,leackage of Refrigerant,Topup of Refrigerant if required, servicing and cleanning of PCB) will be provided by OEM and No extra amounts will be paid on this account. \nNote 2. : Split Type AC 1.5/2TR will be issued under Sch B free for fixing only from MES Store Yard. \n | 66 | Each Job | |
4 | 4 | Fixing only commissioning & testing of window type room air conditioner electric driven of capacity 1.5 TR/2 TR single phase 230 Volt +_ 10% , 50 Hz, AC supply complete with cordless remote control unit Cutting of holes for making opening in existing walls/ aluminium window including grill for hoisting and fixing AC of size 700m x 500mm with required aluminium members/2nd class soft wood for framing to hold window AC unit firmly including connection and making good the disturbed surface to match with the existing. complete all as specified and directed. \nNote 1. :- Half yearly complete servicing of ACs upto 02 Years (Checking refrigerent pressure, Loose Connection,leackage of Refrigerant,Topup of Refrigerant if required, servicing and cleanning of PCB) will be provided by OEM and No extra amounts will be paid on this account.\nNote 2. : Window Type AC 1.5/2TR will be issued under Sch B free for fixing only from MES Store Yard.\n | 224 | Each | |
5 | 5 | Fixing only electronic voltage stablizer for automatic operation single phase, natural air cooled indoor wall mounted type and capacity 5.0 KVA complete all as specified and directed.\nNote:Voltage Stablizer 5 KVA will be issued under Sch B free for fixing only from MES Store Yard.\n | 256 | Each | |
6 | 6 | Supply, install, commissioning and testing of cassette type air conditoner inverter type with hot and cold of capacity 4.1 TR (12000 K Cal/hr) (Non CFC/HCHC) three phase for 415 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit complete comprising of following :-\nModel No IDA48YAFUR3 of blue star or equivalent make model of Make :- Daikin/Hitachi/Blue Star/O-Genral.\n(a) Indoor unit ceiling mounted with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water.\n(b) Out door unit comprising. Compressor with motor,. air cooled copper condenser with fan and motor. unit shall be installed out side the building/ on roof.\n(c) Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable.\n(d) Making good the disturbed surface to match the existing surface after plugging the hole etc.\n(e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wallas per Manufacture's instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 1.5 TR AC complete all as specified and directed. \n(f) Suitable size Electrical cable required to connect out door unit and indoor unit to voltage stablizer inclusive in above rate.\nNote:- Half yearly complete servicing of ACs upto 02 Years (Checking refrigerent pressure, Loose Connection,leackage of Refrigerant,Topup of Refrigerant if required, servicing and cleanning of PCB) will be provided by OEM and No extra amounts will be paid on this account.\n(g) Guarantee as given by manufacurer (minimum 2 yrs) shall be submitted by Contractors as well as contractor is responsible with manufacturer for said gurantee periods.\n\n | 18 | Each | |
7 | 7 | M&L for sub main wiring with Two run of single core 4 Sq.mm for main wire and one run of single core 4 Sq.mm as earth wire of multi stranded copper conductor FRLSH PVC insulated unsheathed cable conforming to IS : 694 drawn through and including surface/concealed in PVC coduit conforming to IS : 9537 ( Part-3) and ISI marked not lass than 20 mm dia and all accessories all conforming to IS specification complete. Note:- Two run of main wire one run earth wire and one run PVC conduit shall be measure as one unit. | 950 | RM | |
8 | 8 | M&L for sub main wiring with Two run of single core 6 Sq.mm for main wire and one run of single core 6 Sq.mm as earth wire of multi stranded copper conductor FRLSH PVC insulated unsheathed cable conforming to IS : 694 drawn through and including surface/concealed in PVC coduit conforming to IS : 9537 ( Part-3) and ISI marked not lass than 20 mm dia and all accessories all conforming to IS specification complete. Note:- Two run of main wire one run earth wire and one run PVC conduit shall be measure as one unit. | 280 | RM | |
9 | 9 | M&L for sub main wiring with four run of single core 16 Sq.mm for main wire and two run of single core 16.0 Sq.mm as earth wire of stranded copper conductor FRLSH PVC insulated unsheathed cable conforming to IS : 694 drawn through and including concealed in wall rigid PVC coduit conforming to IS : 9537 ( Part-3) and ISI marked not lass than 32 mm dia and all accessories all conforming to IS specification complete. \nNote:- Four run of main wire two run earth wire and one run PVC conduit shall be measure as one unit. | 240 | RM | |
10 | 10 | M&L for sub main wiring with four run of single core 10 Sq.mm for main wire and two run of single core 10.0 Sq.mm as earth wire of stranded copper conductor FRLSH PVC insulated unsheathed cable conforming to IS : 694 drawn through and including concealed in wall rigid PVC coduit conforming to IS : 9537 ( Part-3) and ISI marked not lass than 32 mm dia and all accessories all conforming to IS specification complete. \nNote:- Four run of main wire two run earth wire and one run PVC conduit shall be measure as one unit. | 100 | RM | |
11 | 11 | S&F copper tubing of size 1/4" for split type air conditioning with synethic rubber foam insulation complete including making flair and flair nut all as specififed and directed. | 200 | RM | |
12 | 12 | All as per ser item No. 11.00 above but size 1/2". | 200 | RM | |
13 | 13 | All as per ser item No. 11.00 above but size 3/8". | 100 | RM | |
14 | 14 | All as per ser item No. 11.00 above but size 5/8". | 120 | RM | |
15 | 15 | Fixing only Installation, commissioning and testing of water cooler fully stainless steel. Electric driven single phase having approx storage and nominal cooling capacity 40/80 Ltr including dismantling old water cooler and depositing to MES Yard.all as specififed and directed.\nNote : Water Cooler will be issued under Sch B free for fixing from MES Store Yard. | 33 | Each | |
16 | 16 | Fixing only Installation, commissioning and testing of water cooler fully stainless steel. Electric driven single phase having approx storage and nominal cooling capacity 60/120 Ltr including taking down old water cooler and depositing to MES Yard all as specififed and directed. \nNote : Water Cooler will be issued under Sch B free for fixing from MES Store Yard. | 6 | Each | |
17 | 17 | Fixing only Installation, commissioning testing of water cooler fuuly stainless steel. Electric driven single phase having approx storage and nominal cooling capacity 150/180 Ltr including taking down old water cooler and depositing to MES Yard complete all as specified and directed.\nNote : Water Cooler will be issued under Sch B free for fixing from MES Store Yard. | 15 | Each | |
18 | 18 | Fixing only desert cooler electric driven(single phase), having nominal air flow capacity of 4000 Cum per hour with including taking down old desert cooler and depositing to MES Yard.\nNote : Desert Cooler will be issued under Sch B free for fixing from MES Store Yard. | 140 | Each | |
19 | 19 | Fixing only ceiling fan 1200 mm/1400mm sweep with provision of flexible cord 3 core stranded copper conductor of size 1.50 sqmm from connector block to fan including connection to earthing point ES-50 5 Star White with fan regulator including dismantling and depositing to MES Yard.\nNote : Ceiling fan 1200mm sweep will be issued under Sch B free for fixing from MES Store Yard. | 1141 | Each | |
20 | 20 | Fixing only ceiling fan 1400 mm sweep with provision of flexible cord 3 core stranded copper conductor of size 1.50 sqmm from connector block to fan including connection to earthing point ES-50 5 Star White with fan regulator including taking down and depositing to MES Yard.\nNote : Ceiling fan 1400mm sweep will be issued under Sch B free for fixing from MES Store Yard. | 363 | Each | |
21 | 21 | Fixing only wall mounted fan 400 mm sweep heavy duty three speed with regulator with cord and with osicallating motion high speed 230 volt single phase 50Hz including flexible cord 3 core stranded copper conductor of size 1.50 sqmm from connector block to fan including connection to earthing point including taking down and depositing to MES Yard. \nNote : Wall fan 400mm sweep will be issued under Sch B free for fixing from MES Store Yard. | 61 | Each | |
22 | 22 | Fixing only Exhaust fan 450 mm sweep with louvers, operated on 230/240V AC Single phase electric supply 1400 RPM complete duly grauted bolts in the wall fixed with nuts, bolt and washers including making suitable size hole in the wall, plastering, white washing or colour washing to the disturbed surface if required of wall complete matching with the existing including connecting with 3 core stranded copper conductor cable cord of size 1.5 sqmm from ceiling rose to fan connector including taking down and depositing to MES Yard complete all as specified and directed.\nNote : Exhaust Fan 450mm sweep will be issued under Sch B free for fixing from MES Store Yard. | 94 | Each | |
23 | 23 | Fixing only exhaust fan 380 mm sweep with louvers, operated on 230/240V AC Single phase electric supply 1400 RPM complete duly grauted bolts in the wall fixed with nuts, bolt and washers including making suitable size hole in the wall, plastering, white washing or colour washing to the disturbed surface if required of wall complete matching with the existing including connecting with 3 core stranded copper conductor cable cord of size 1.5 sqmm from ceiling rose to fan connector including taking down and depositing to MES Yard complete all as specified and directed. \nNote : Exhaust Fan 380 sweep will be issued under Sch B free for fixing from MES Store Yard. | 11 | Each | |
24 | 24 | Fixing only exhaust fan 300 mm sweep with louvers, operated on 230/240V AC Single phase electric supply 1400 RPM complete duly grauted bolts in the wall fixed with nuts, bolt and washers including making suitable size hole in the wall, plastering, white washing or colour washing to the disturbed surface if required of wall complete matching with the existing including connecting with 3 core stranded copper conductor cable cord of size 1.5 sqmm from ceiling rose to fan connector including taking down and depositing to MES Yard complete all as specified and directed.\nNote : Exhaust Fan 300mm sweep will be issued under Sch B free for fixing from MES Store Yard. | 50 | Each | |
25 | 25 | Fixing only pedestal fan 400 mm sweep heavy duty three speed with regualtor and with osicallating motion high speed 230 volt single phase 50Hz including flexible cord 3 core stranded copper conductor of size 1.50 sqmm with top plug including taking down and depositing to MES Yard. \nNote :Pedstal Fan 400 sweep will be issued under Sch B free for fixing from MES Store Yard. | 10 | Each | |
26 | 26 | S&F of RO water purifier wall mounted for multiple (RO+UV+UF+TDS control) electric operated single phase 230Volt with water storage capacity 8 Ltr of food grade plastic body and flow rate 15 Ltr per hour with cord end plug top including taking down and depositing to MES Yard complete all as specified and directed. \nMake: Kent/water purifir/Aqua fresh | 1 | Each | |
27 | 27 | Fixing only electric water heater storage type(Geyser) ISI marked, maintenace friendly 50 Ltr capacity 5 star, 230 Volt single phase AC with inner stainless steel tank with copper element and adjustable thermostate and 3 core wire flexible cord copper conductor including one hot water and one cold water PVC connection 300mm long including taking down of old Geyser and depositing to MES Yard complete all as specified and directed. Make:- Havells/BAJAJ/Crompton \nNote : Geyser 50 Ltr will be issued under Sch B free for fixing from MES Store Yard. | 2 | Each | |
28 | 28 | Fixing only electric water heater storage type(Geyser) ISI marked, maintenace friendly 25 Ltr capacity 5 star, 230 Volt single phase AC with inner stainless steel tank with copper element and adjustable thermostate and 3 core wire flexible cord copper conductor including one hot water and one cold water PVC connection 300mm long including taking down of old Geyser and depositing to MES Yard complete all as specified and directed. \nMake:- Havells/BAJAJ/Crompton \nNote : Geyser 25 Ltr will be issued under Sch B free for fixing from MES Store Yard. | 5 | Each | |
29 | 29 | Supply and Fixing industrial type plug socket, SPN and earth plug 250V, 20 Amps with steel enclosure and one MCB SP 20/32 Amps complete all as specified and directed. | 290 | Each | |
30 | 30 | Supply and Fixing industrial type plug socket, TPN and earth plug 5 pin, 415V,63 Amps with steel enclosure and one MCB TP 63 Amps complete all as specified and directed. | 18 | Each | |
31 | 31 | S&F PVC 20mm dia rigid pipe medium grade ISI marked fixed on wall/floor with MS clamb and fastner complete all as specified and directed. | 750 | RM | |
32 | 32 | S&F 3 Core copper cable PVC sheated of size 2.5 Sqm including connection complete | 540 | RM | |
33 | 33 | S&F 3 Core copper cable PVC sheated of size 4.0 Sqm including connection complete | 350 | RM | |
34 | 34 | S&F 4 Core copper cable PVC sheated of size 6 Sqm including connection complete | 150 | RM | |
35 | 35 | Supply and fixing sheet metal enclosure for DBs when MCBs to be used single pole and neutral double door, 240 volt with 200 Amp bus bar 8 way flush in wall complete all as specified and directed. | 10 | Each | |
36 | 36 | Supply and fixing sheet metal enclosure when MCBs to be used three pole and neutral double door, 415 volt with 200 Amp bus bar 4 way flush in wall complete all as specified and directed. | 4 | Each | |
37 | 37 | Supply and fixing factory made epoxy powder coated distribution board VTP & N 8 ways (TPN MCCB DB) with metal door (IP-43protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TP-MCCB 125 Amps as incomer and 24 SP MCBs or 8 TP MCBs (or any combination of SP/TP MCBs) outgoings complete all as specified and directed.\nMake :- Legrand/Havels/L&T/ABB. | 4 | Each | |
38 | 38 | S&F MCCB TPN ,Thermal magnatic with enclouser , 415 Volts,50 HZ, 25 KA, 200 Amps. \nMake: Legrand /Indo asian/L&T/Siemens. | 4 | Each | |
39 | 39 | S&F MCB 415 Volts 63 Amps, 10KA 04 pole 'C' series complete all as specified. | 4 | Each | |
40 | 40 | S&F MCB 240 Volts 40 Amps, 10KA SPN 'C' series complete all as specified. | 10 | Each | |
41 | 41 | S&F MCB 240 Volts 6 Amp to 32 Amp SP 10 KA 'C' series complete all as specified. | 100 | Each | |
42 | 42 | S&F MCB 415 Volts 40 Amps, 10KA 03 pole 'C' series complete all as specified. | 18 | Each | |
43 | 43 | Taking down MCCBs DB alongwith MCCB/MCBs of any description complete all as specified and directed. | 5 | Each Set | |
44 | 44 | Taking down MCBs industrial type plug socket, SPN and earth plug 250V, 20 Amps with steel enclosure and one MCB SP 20/32 Amps complete all as specified and directed. | 100 | Each | |
45 | 45 | M&L for fabrication of desert cooler stand with angle iron of Size 40x40x 3mm duly painted 2 coat of synthetic enamel paint over a coat of red oxide primer inlcuding welding etc all as directed. | 1400 | Kg |