| 1 | 1 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work – Exposed on wall. | Item 1 | | |
|---|
| 2 | 1.01 | 15 mm dia. Nominal bore | Item 2 | 180 | metre |
|---|
| 3 | 1.02 | 20 mm dia. Nominal bore | Item 3 | 180 | metre |
|---|
| 4 | 2 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. | Item 4 | | |
|---|
| 5 | 2.01 | 15 mm dia. Nominal bore | Item 5 | 144 | metre |
|---|
| 6 | 2.02 | 20 mm dia. Nominal bore | Item 6 | 180 | metre |
|---|
| 7 | 2.03 | 50 mm dia. Nominal bore | Item 7 | 600 | metre |
|---|
| 8 | 2.04 | 80 mm dia. Nominal bore | Item 8 | 30 | metre |
|---|
| 9 | 3 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : | Item 9 | | |
|---|
| 10 | 3.01 | 25 to 40 mm nominal bore | Item 10 | 30 | each |
|---|
| 11 | 3.02 | 50 to 80 mm nominal bore | Item 11 | 10 | each |
|---|
| 12 | 4 | Providing and fixing brass stop cock of approved quality : | Item 12 | | |
|---|
| 13 | 4.01 | 15 mm dia. Nominal bore | Item 13 | 32 | each |
|---|
| 14 | 4.02 | 20 mm dia. Nominal bore | Item 14 | 32 | each |
|---|
| 15 | 5 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : | Item 15 | | |
|---|
| 16 | 5.01 | 50 mm dia. Nominal bore | Item 16 | 10 | each |
|---|
| 17 | 5.02 | 80 mm dia. Nominal bore | Item 17 | 2 | each |
|---|
| 18 | 6 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : | Item 18 | | |
|---|
| 19 | 6.01 | For 150 mm diameter Class I | Item 19 | 4 | each |
|---|
| 20 | 7 | Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design : with F.P.S. bricks | Item 20 | 30 | each |
|---|
| 21 | 8 | Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size ) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : with F.P. S. bricks | Item 21 | 4 | each |
|---|
| 22 | 9 | Constructing masonry Chamber 120x120x100 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : with F.P.S. bricks | Item 22 | 4 | each |
|---|
| 23 | 10 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) | Item 23 | | |
|---|
| 24 | 10.01 | 15 mm dia. Nominal bore | Item 24 | 38 | each |
|---|
| 25 | 10.02 | 20 mm dia. Nominal bore | Item 25 | 32 | each |
|---|
| 26 | 10.03 | 50 mm dia. Nominal bore | Item 26 | 10 | each |
|---|
| 27 | 10.04 | 80 mm dia. Nominal bore | Item 27 | 2 | each |
|---|
| 28 | 11 | Demolishing cement concrete manually/ by mechanical means including disposal of material within IIP campus as per direction of Engineer - in - charge. For 1:3:6 or recher mix | Item 28 | 7 | cum |
|---|
| 29 | 12 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes and depositrd in IIP store yard as per direction of Engineer-in-charge : | Item 29 | | |
|---|
| 30 | 12.01 | 15 mm to 40 mm nominal bore | Item 30 | 162 | metre |
|---|
| 31 | 12.02 | Above 40 mm nominal bore | Item 31 | 665 | metre |
|---|
| 32 | 13 | Demolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within IIP campus as per direction of Engineer-in-charge. | Item 32 | 6 | cum |
|---|
| 33 | 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : | Item 33 | | |
|---|
| 34 | 14.01 | 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | Item 34 | 7 | cum |
|---|
| 35 | 15 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. | Item 35 | 40 | cum |
|---|
| 36 | 16 | Providing and fixing 150 mm nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc . | Item 36 | 325 | metre |
|---|