| 1 | 1 | Earth work in excavation for foundation of structure complete with all lift, dewatering shoring and shuttering etc.including refilling of trenches in 25.mm layers, ramming, watering and disposal of surplus soil within a lead of 1000 metres, as per drawing and technical specfication.[MoRTH Specification : Clause : 304] In ordinary Soil [MoRTH Specification : Clause : 301] | BI01010001010000000000000515BI0100001113 | 157.31 | Cum. |
|---|
| 2 | 2 | In Hard Soil [MoRTH Specification : Clause : 301] | BI01010001010000000000000515BI0100001114 | 40.89 | Cum. |
|---|
| 3 | 3 | Providing, laying and compacting plain/ reinforced cement concrete of specified grade in foundation/ leveling course/ pile cap using concrete mixer and vibrater complete including cost of form work, as per drawing and technical specifications and as per clause 1100, 1500,1700,2100 of MoRT&H specification including all scaffolding material, labour, machineryP.C.C. M15 grade | BI01010001010000000000000515BI0100001115 | 18.37 | Cum. |
|---|
| 4 | 4 | PCC Grade M -25 | BI01010001010000000000000515BI0100001116 | 70.17 | Cum. |
|---|
| 5 | 5 | PCC Grade M -20 | BI01010001010000000000000515BI0100001117 | 27.47 | Cum. |
|---|
| 6 | 6 | Random rubble masonry work in cement mortar with mechanical mixer in substructure/ super structure at all levels complete as per clause 1400 and 2200 of MoRT&H specification including all material, labour, scaffolding etc but excluding pointing and plastering. In cement mortar 1:4 (1 cement : 4 coarse sand) | BI01010001010000000000000515BI0100001118 | 14.69 | Cum. |
|---|
| 7 | 7 | Supplying, fitting and placing TMT bar reinforcement in sub\nstructure/ superstructure at all level complete as per drawing and clause 1600 & 2200 of MoRT&H Specification including all material,labour, machinary etc. | BI01010001010000000000000515BI0100001119 | 4.1 | MT |
|---|
| 8 | 8 | Providing weep holes in brick/ stone masonry/ Plain/ Reinforced concrete abutment, wing wall/ return wall with following dia AC pipe,extending through the full width of the structure with slope of 1V : 20H towards drawing face complete as per drawing, technical specifications and clause 2205 of MoRT&H Specification including all scaffolding, material, labour, machinery etc. 100 mm dia | BI01010001010000000000000515BI0100001120 | 22 | Mtr |
|---|
| 9 | 9 | Providing and laying reinforced cement concrete wearing coat M-30 grade at any level including formwork and reinforcement @\n75kg/cum complete as per drawing and technical specification and as per clause 2702 of MoRT&H Specification including all material,labour, machinary etc. | BI01010001010000000000000515BI0100001121 | 4.9 | Cum. |
|---|
| 10 | 10 | Construction of precast/ cast-in-situ RCC railing M-30 grade,true to line and grade, center to center spacing between vertical post not to exceed 2000mm leaving adequate space between vertical post for expansion, complete as per drawing and technical specification and as per clause 1500, 1600, 1700 & 2703 of MoRT&H Specification including all material, labour, machinary etc. | BI01010001010000000000000515BI0100001122 | 20.88 | Mtrs. |
|---|
| 11 | 11 | Providing and laying expansion joint complete as per drawing and technical specification and as per clause 2605 of MoRT&H\nSpecification including all material, labour, machinary etc. Fillar joint with 20m thick compressible fibre board. | BI01010001010000000000000515BI0100001123 | 7.74 | Sqm |
|---|
| 12 | 12 | Providing and laying Precast Reinforced cement concrete slab for footpath and median with approved finish, constructed with specified grade concrete as per dimensions in the approved drawing and at locations directed by the Engineer including form work and excluding reinforcement and complete as per clause 1500 & 1700 of MoRT&H specification including all material, labour, machinery.RCC M-20 | BI01010001010000000000000515BI0100001124 | 9.35 | Cum. |
|---|
| 13 | 13 | Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 3 metre long and size 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing including all material, labour 90 cm equilateral triangle | BI01010001010000000000000515BI0100001125 | 2 | Nos |
|---|
| 14 | 14 | Providing and erecting direction and place identification retroreflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick framed to angle iron 40x40x5mm with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing including all material, labour | BI01010001010000000000000515BI0100001126 | 2 | Sqm |
|---|
| 15 | 15 | Back filing in foundation, trench behind abutment, wing wall and return wall etc and below pipe bed in layers not exceeding 20cm in depth, consolidating each deposited layer compacted by mechanical means with all lead and lift as per drawing and technical specification including all material, labour, machinery as per clause 2100 and 2200 of MoRT&H specification including all material, labour, machinery | BI01010001010000000000000515BI0100001127 | 6.36 | Cum |
|---|