| 1 | 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms , lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50m -All kinds of soil. | 2.8.1 | 184 | cum |
|---|
| 2 | 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m. | 2.25 | 184 | cum |
|---|
| 3 | 3 | Extra for every additional lift of 1.5mor\npart there of in excavation / bankingexcavated or stacked materials - all kinds\nof soil\n | 2.26.1 | 48 | cum |
|---|
| 4 | 4 | Supplying and filling in plinth with sand \n under floors including, watering, ramming\n consolidating and dressing complete.\n | 2.27 | 35 | cum |
|---|
| 5 | 5 | Reinforcement for R.C.C work including \n straightening , cutting , bending , placing\n in position and binding all complete -\n Thermo - Mechanically treated bars ISI brand of approved makeincluding placing the M30 grade Athees make cover block @ 60cm centre to centre | 30.7 | 495 | cum |
|---|
| 6 | 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering.- All workupto plinth level -1:4:8 (1 cement:4 course sand : 8 graded stone aggregate 40mm nominal size) \n | 4.1.8 | 35 | cum |
|---|
| 7 | 7 | Providing and laying cement concrete in retaining walls,return walls (any thickness) including attached pilasters, columns,piers abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping bed blocks , anchor blocks, plain window sills,fillets sunken floor etc upto floor five level,excluding the cost of centring,shuttering and finishing:1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20mm nominal size) | 4.2.5 | 1.65 | cum |
|---|
| 8 | 8 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering,shuttering,finishing and reinforcement -All work upto plinth level : 1:1.5:3 (1 cement : 1 .5 coarse sand : 3 graded stone aggregate 20mm nominal size) | 5.1.2 | 45 | cum |
|---|
| 9 | 9 | Reinforced cement concrete work in walls (any thickness), including attached pilasters , buttresses, plinth and string courses , fillets, columns , pillars, piers, abutments, posts \nand struts etc.upto floor five level excluding cost of centering, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5coarse sand : 3 graded stone aggregate 20mm nominal size) \n | 5.2.2 | 15 | cum |
|---|
| 10 | 10 | Reinforced cement concrete work in beams, suspended floors , roofs having slope up to 15degree landings , balconies , shelves , chajjas , lintels , bands , plain window sills , staircases and spiral stair cases upto floor five level excluing the cost of centering ,shuttering, finishing and reinforcement , with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) | 5.3 | 57 | cum |
|---|
| 11 | 11 | Centring and shuttering including strutting, propping etc.and removal of form for:Foundations , footings, bases of columns ,etc. for mass concrete. | 5.9.1 | 190 | sqm |
|---|
| 12 | 12 | Centring and shuttering including strutting, propping etc. And removal of form for : suspended floors, roofs, landings, balconies and access platform. | 5.9.3 | 267 | sqm |
|---|
| 13 | 13 | Centring and shuttering including strutting, propping etc. And removal of form for: lintels, beams, plinth beams, girders, bressumers and cantilevers. | 5.9.5 | 170.02 | sqm |
|---|
| 14 | 14 | Centring and shuttering including strutting, propping etc. And removal of form for: columns, pillars, piers, abutments, posts and struts.- | 5.9.6 | 184 | sqm |
|---|
| 15 | 15 | Centring and shuttering including strutting, propping etc. and removal of form for: Stairs (excluding landings) except spiral - staircases - | 5.9.7 | 17.14 | sqm |
|---|
| 16 | 16 | Centring and shuttering including strutting, propping etc.and removal of form for: Edges of slabs and breaks in floors and walls.Under 20 cm wide - | 5.9.16.1 | 17 | metre |
|---|
| 17 | 17 | Steel Reinforcement for R.C.C work including straightening , cutting , bending , placing in position nd binding all complete –upto plinth level Thermo-Mechanically treated bars (TISCON / VIZAG / IISCO /SAIL/JSW) Fe-415 or more. | 5.22.6 | 5300 | Kg |
|---|
| 18 | 18 | Steel reinforcement for R.C.C. work including straightening , cutting , bending , placing in position and binding all complete above plinth level - Thermo - Mechanically Treated bars (TISCON / VIZAG / IISCO / SAIL / JSW) Fe - 415 or more | 5.22A.6 | 9600 | Kg |
|---|
| 19 | 19 | Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 7.5 in foundation and plinth in - cement mortar 1:6 (1 cement : 6 coarse sand) | 6.1.2 | 16 | cum |
|---|
| 20 | 20 | Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:4 ( 1 cement : 4 coarse sand) | 6.4.1 | 2.05 | cum |
|---|
| 21 | 21 | Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:6 ( 1 cement : 6 coarse sand) | 6.4.2 | 105 | cum |
|---|
| 22 | 22 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level - cement mortar 1:4 (1 cement : 4 coarse sand) | 6.13.2 | 6.35 | sqm |
|---|
| 23 | 23 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. | 16.1 | 32 | sqm |
|---|
| 24 | 24 | Providing wood work in frames of doors, windows, clerestory windows and other frames , wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) -Padak wood | 9.1.2P | 0.45 | cum |
|---|
| 25 | 25 | Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part 1)non-decorative type, core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. - 35 mm thick including ISI marked stainless steel butt hinges with necessary screws | 9.21.1 | 16.5 | sqm |
|---|
| 26 | 26 | Extra for cutting rebate in flush door shutters (total area of the shutter to be area measured) | 9.26 | 16.5 | sqm |
|---|
| 27 | 27 | Providing 40x5 mm flat iron hold fast 40cm long including fixing to frame with 10mm\n diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)\n | 9.53 | 48 | each |
|---|
| 28 | 28 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :- 125x85x5.5mm (heavy type) | 9.72.1 | 56 | each |
|---|
| 29 | 29 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. | 9.76 | 8 | each |
|---|
| 30 | 30 | Providing and fixing bright finished brass door latch with necessary screws etc. complete - 300x16x5mm | 9.75.1 | 16 | each |
|---|
| 31 | 31 | Providing and fixing bright finished brass door latch with necessary screws etc.complete - 250 x16x5mm | 9.75.2 | 16 | each |
|---|
| 32 | 32 | Providing and fixing bright finished brass handles with screws etc. complete: 125mm | 9.81.1 | 18 | each |
|---|
| 33 | 33 | Providing and fixing factory made P.V.C.door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joinedwith 2nos.of 150mm long brackets of 15 x 15mm M.S.square tube, the vertical door frame profiles to be reinforced with 19x19mm M.S.square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using M.S.screws of 65/100mm size complete as per manufacturers specification\n | 9.119 | 15 | metre |
|---|
| 34 | 34 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S.tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15 x15 mm for top & bottom rails. M.S.frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top , bottom and lock rails shall be provided both side of the panel. 10mm (5 mm x 2) thick , 20 mm wide cross\nDescription of item PVC sheet be provided as gap insert for top rail & bottom rail , panelling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded / sealed to the styles & rails with 7 mm (5 mm + 2 mm) thick x 15 mm wide PVC sheet beading on inner side , and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C\" Channel using PVC solvent adhesive etc. complete manufacturer's specification & drawing - 30mm thick plain PVC door shutters \n | 9.120.1 | 5 | sqm |
|---|
| 35 | 35 | Providing and fixing of 65mm godrej Navtal lock of 6 levers etc complete | 9.165.1A | 8 | no. |
|---|
| 36 | 36 | Supplying and fixing of steel grill work of m.s.angles,flats,squares and pipes including cost of welding charges, fixing in position in masonry walls with cement concrete 1:2:4 (1 cement : 2 course sand : 4 graded stone aggregate 12.5mm nnominal size) including one Coat of priming coat etc. complete. | NPSR1 | 1200 | Kg |
|---|
| 37 | 37 | Providing and fixing 1st quallity ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacture of approved make (Jhonson / Asian / Somany / Nitco) in all colours, shades of size 300 x 450 mm as approved in skirting, risers of steps and dados over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm. Including pointing in white cement with pigment of matching shade complete. -size 300x450mm | 11.36B | 57 | sqm |
|---|
| 38 | 38 | Providing and laying rectified ceramic rustic / matt finish floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make (Somany / Nitco) in all colours , shades, except white, ivory, grey, fume red brown, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigments etc., complete | 11.40.1 | 13 | sqm |
|---|
| 39 | 39 | Providing and laying fully vitrified floor tiles of size 600x600mm (thicknes to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS: 15622 of approved make (Nitco / Rak / Johnson / Asian) in all colors and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600mm. | 11.41.2A | 255 | sqm |
|---|
| 40 | 40 | Providing and laying 22mm thick factory made pre polished cement concrete flooring tiles of required colour and design over 20mm thick cement mortar 1:4 ( 1 cement : 4 sand) and jointed with cement slurry mixed with an admixture of pigment to match the shade of the tile - (Endura \ Ultra \ Dazzle \ Technic) | 11.61 | 44 | sqm |
|---|
| 41 | 41 | Providing and fixing PVC corner beading of required size to suit the thickness of the wall tile at the corner joints of dado works | 11.62 | 30 | metre |
|---|
| 42 | 42 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. - Granite of any colour and shade - Area of slab over 0.50 sqm | 8.2.2.1 | 4.1 | sqm |
|---|
| 43 | 43 | Providing edge moulding to 18mm thick marble stone counters, vanities, etc., including machine polishing to edge to give high gloss finish etc., complete. -Granite work | 8.3.2 | 14.5 | metre |
|---|
| 44 | 44 | Painting top of roofs with bitumen of approved quality at 17kg per 10sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete: With residual type petroleum bitumen of grade,VG-10. | 12.15.1 | 165 | sqm |
|---|
| 45 | 45 | Providing and laying pressed clay tiles (as per approved pattern 20mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% intergral water proofing compound laid over a bed of 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. | 12.2O | 175 | sqm |
|---|
| 46 | 46 | Lime concrete terracing on roofs of required thickness laid to fall with 25mm nominal size brick aggregate and 50% lime mortar 1:2 (1 lime putty : 2 surkhi) rammed and finished with gur and belgiri treatment complete including rounding of junctions with parapet wall complete | 12.20L | 30 | cum |
|---|
| 47 | 47 | Making khurras 45 X 45cm with average minimum thickness of 5cm cement concrete 1:2:4 (1 cement : 2coarse sand : 4 graded stone aggregate of 20mm nominal size) over P.V.C. sheet 1mX1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge and making and finishing outlet complete. | 12.22 | 10 | no. |
|---|
| 48 | 48 | Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS : 13592 type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion, (i) single socketed pipes. 110mm diameter. | 12.41.2 | 80.5 | metre |
|---|
| 49 | 49 | Providing and fixing on wall face unplasticised- PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS : 13592 type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. Single Tee with out door 10X110X110mm. | 12.42.4.2 | 10 | no. |
|---|
| 50 | 50 | Providing and fixing on wall face unplasticised- PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS : 13592 type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. Shoe (plain)110mm shoe. | 12.42.6.2 | 10 | no. |
|---|
| 51 | 51 | Providing and fixing unplasticised - PVC pipe clips of approved design to nplasticised - PVC rain water pipes by means of 50x50x50mmhard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4(1 cement : 4 coarse and) and making good the wall etc. complete. 110mm | 12.43.2 | 80 | no. |
|---|
| 52 | 52 | Providing and fixing PVC false roofing with the existing PVC cabin using sintex PVC section of size 6mm x 250mm, having interlocking facilities supported in the PVC extruded multi chamber frame section of 40 x 48mm, with necessary MS / Stainless screws. The rate includes the cost of sintex PVC section, labour charges for fixing transport etc., Complete. | 16.97 | 166.56 | sqm |
|---|
| 53 | 53 | 12 mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1cement : 4 fine sand) | 13.7.2 | 615 | sqm |
|---|
| 54 | 54 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1cement : 4 fine sand) | 13.8.2 | 475 | sqm |
|---|
| 55 | 55 | 6mm cement plaster of mix 1:3 (1 \ncement : 3 fine sand).\n | 13.16.1 | 247 | sqm |
|---|
| 56 | 56 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. | 13.21 | 18.2 | per bag of cement |
|---|
| 57 | 57 | Providing and applying ready mixed wall putty (JK / BIRLA ) of 2mm thickness over plastered surface to prepare the surface even and smooth complete | 13.26A | 655 | sqm |
|---|
| 58 | 58 | 12mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand)- Flush Band. | 13.28.1 | 586.2 | Cm per metre |
|---|
| 59 | 59 | White washing with lime to give on even shade - New work ( three or more coats). | 13.37.1 | 305 | sqm |
|---|
| 60 | 60 | Applying one coat of water thinnable cement primer of approved brand and manufacturer on wall surface - water thinnable cement primer | 13.43.1 | 560 | sqm |
|---|
| 61 | 61 | Finishing walls with acrylic smooth exterior paint of required shade - New work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm | 13.46.1 | 500 | sqm |
|---|
| 62 | 62 | Applying priming coat - with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft\nwood). \n | 13.50.1 | 20 | sqm |
|---|
| 63 | 63 | Applying priming coat - with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat). | 13.50.4 | 25 | sqm |
|---|
| 64 | 64 | Wall painting with plastic emulsion paint Royal of approved brand and manufacture to give an even shade - two or more coats on new work | 13.60.1A | 655 | sqm |
|---|
| 65 | 65 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade - Two or more coats on new work. | 13.61.1 | 680 | sqm |
|---|
| 66 | 66 | Providing and fixing white vitreous china pan pedestal type watercloset (European type W.C. pan) with seat and lid, 10 lite low level white P.V.C. flushing cistern including flushing pipe with manually controlled device (handle lever), conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. W.C pan with ISI marked white solid plastic seat and lid\n | 17.2.1 | 3 | nos. |
|---|
| 67 | 67 | Providing and fixing wash basin with CI brackets, 15mm CP brass pillar taps 32 mm CP brass waste of standard pattern including painting of fittings and brackets, cutting and making good the walls wherever required White vitreous china flat back wash basin size 550x400mm with single 15mm CP brass pillar taps. | 17.7.4 | 3 | no. |
|---|
| 68 | 68 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing rectangular shape 453x357mm. | 17.32.2 | 3 | no. |
|---|
| 69 | 69 | Providing and fixing M.S holder bat clamps bat of approved design to sand cast iron /cast iron (spun) pipe embedded inand including cement concrete blocks 10x10x10 cm of 1:2:4 (one cement:two coarse sand:four graded stoneaggregate20mm nominal size) including cost of cutting holes and making good the walls etc. For 100mm dia pipe. | 17.37.1 | 24 | each |
|---|
| 70 | 70 | Providing and fixing M.S holder bat clamps bat of approved design to sand cast iron /cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 (one cement:two coarse sand:four graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. for 75mm dia pipe. | 17.37.2 | 48 | each |
|---|
| 71 | 71 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors 100 mm inlet and 75 mm outlet- sand cast iron S&S as per IS: 1729 | 17.60.2.2 | 6 | no. |
|---|
| 72 | 72 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 450 mm long towel rail with total length of 495mm, 78mm wide and effective height of 88mm, weighing not less than 170gm. | 17.73.1 | 3 | no. |
|---|
| 73 | 73 | Providing and fixing on wall /column face unplasticed - PVC soil and waste pipes(type-B) conforming to IS:13592-1992 including jointing with seal ring conformation to IS: 5382 leaving 10mm gap for thermal expansion - single socketed pipes 110mm diameter | 19.33.1 | 44 | metre |
|---|
| 74 | 74 | Providing and fixing on wall face/column face unplasticised- PVC moulde fittings/accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735-1999 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion - bend 110mm | 19.33.1C | 3 | each |
|---|
| 75 | 75 | Providing and fixing on wall/column face unplasticised - PVC soil and waste pipes (type B) conforming to IS:13592 - 1992 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - single socketed pipes 75mm diameter | 19.33.2 | 65 | metre |
|---|
| 76 | 76 | Providing and fixing on wall face / column face unplasticised - PVC moulded fittings /accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735 - 1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - bend 75mm | 19.33.2C | 15 | each |
|---|
| 77 | 77 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. Concealed work including cutting chases and making good the walls etc. - 15mm nominal outer dia pipes. | 18.8.1 | 75 | metre |
|---|
| 78 | 78 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete Concealed work including cutting chases and making good the walls etc. - 25mm nominal outer dia pipes. | 18.8.3 | 234 | metre |
|---|
| 79 | 79 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings this included jointing of pipes &fittings with one step CPVC solvent cement, trenching refilling & testing of joints complete External work -40mm nominal outer dia pipes. | 18.9.5 | 120 | metre |
|---|
| 80 | 80 | Providing and fixing brass bib cock of approved quality - 15 mm nominal bore. | 18.15.1 | 18 | no. |
|---|
| 81 | 81 | Providing and fixing gun metalgatevalve with CI wheel of approved quality (screwed end) - 25 mm nominal bore. | 18.17.1 | 36 | no. |
|---|
| 82 | 82 | Providing and fixing gun metalgatevalve with CI wheel of approved quality (screwed end) - 40 mm nominal bore. | 18.17.3 | 6 | no. |
|---|
| 83 | 83 | Providing and fixing uplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore. | 18.21.2.1 | 54 | each |
|---|
| 84 | 84 | Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete new work 15 mm nominal bore. | 18.46.1 | 30 | each |
|---|
| 85 | 85 | Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete(new work) 25 mm nominal bore. | 18.46.3 | 30 | each |
|---|
| 86 | 86 | Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) 40 mm nominal bore. | 18.46.5 | 20 | each |
|---|
| 87 | 87 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank - Circular Tank | 18.48A | 5000 | litre |
|---|
| 88 | 88 | Providing and fixing CP brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 - 15mm nominal bore. | 18.53.1 | 6 | each |
|---|
| 89 | 89 | Providing and fixing PTMT soap dish holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements weighing not less than 106grams. | 18.65 | 3 | each |
|---|
| 90 | 90 | Supply and fixing of side hung window at all levels made out of unplasticised Polyvinyl chloride frame from approved make of natural colour with casement outer frame of size 56x48x30mm , shutter frame 66x56x30mm with wall thickness of 1.8mm (+/-0.3mm) and 5mm thick , clear glass . The asket should be made of EPDM (Ethylene propylene dimonomer) with double gasket sealing and applying silicone sealants outside and acrylic sealent inside. The sections should be reinforced with GI sheet of 1.5mm thick with suitable drainage grouting including all necessary hardware fittingsetc.,all complete as per architectural drawings and the engineer -in - charge. | NPSR2 | 22 | sqm |
|---|