Construction Of 02 ( Two ) Nos Cwr ( 10000 Gallon Capacity ) With Pump House In C Allied Works Within The Jurisdiction Of Dws Sub-Division Damcherra .
Tender Value
23.59 Lakhs
Estimated cost
Bid Submission
24 Dec 2020
0 days left
EMD
23597
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Damcherra → Tripura
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of 02 ( Two ) Nos Cwr ( 10000 Gallon Capacity ) With Pump House In C Allied Works Within The Jurisdiction Of Dws Sub-Division Damcherra .
BOQ
| Name of Work: JJM/ RURBAN Scheme in North Tripura District during the year 2020-21/ Construction of INNOVATIVE SCHEME by amalgamation of 2(two) nos Masonry Well followed by CWR(10000 Gallon)/ SH: Construction of 02(two) nos CWR (10000 Gallon Capacity) with Pump House in/c allied works within the jurisdiction of DWS Sub-Division Damcherra./ Gr.I | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | SH : CWR | BI01010001010000000000000515BI0100001179 | ||
| 2 | 2 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. | BI01010001010000000000000515BI0100001180 | 450 | sqm |
| 3 | 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.\n-All kinds of soil | BI01010001010000000000000515BI0100001181 | 828 | cum |
| 4 | 4 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. \n-All kinds of soil | BI01010001010000000000000515BI0100001182 | 78.918 | cum |
| 5 | 5 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. | BI01010001010000000000000515BI0100001183 | 5.102 | cum |
| 6 | 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.\n'-All kinds of soil | BI01010001010000000000000515BI0100001184 | 52.612 | cum |
| 7 | 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -All work upto plinth level: \n4.1.6) 1:3:6 ( 1 Cement: 3 fine sand : 6 graded well burnt stone aggregate 40 mm nominal size | BI01010001010000000000000515BI0100001185 | 5.102 | cum |
| 8 | 8 | First class brick work in foundation and plinth including cost of all materials as required complete\n6.1.3) In cement mortar 1:4 ( 1 cement : 6 fine sand ). | BI01010001010000000000000515BI0100001186 | 0.252 | cum |
| 9 | 9 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-All work upto plinth level:\n5.1.1) 1:1:2 ( 1 Cement: 1 fine sand : 2 graded stone aggregate 20 mm nominal size).\n | BI01010001010000000000000515BI0100001187 | 10.804 | cum |
| 10 | 10 | Reinforced cement concrete work in walls (any\nthickness), including attached pilasters, buttresses,plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-\n5.2.1) 1:1:2 ( 1 Cement: 1 fine sand : 2 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001188 | 14.81 | cum |
| 11 | 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-\n5.3.1) 1:1:2 ( 1 Cement: 1 fine sand : 2 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001189 | 11.98 | cum |
| 12 | 12 | Centering shuttering including struttings, propping etc. and removal of form work for: | BI01010001010000000000000515BI0100001190 | ||
| 13 | 13 | 5.8.1.2) Foundations, footings, bases for columns etc. for mass concrete with steel formwork | BI01010001010000000000000515BI0100001191 | 14.792 | sqm |
| 14 | 14 | 5.8.3) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. using shuttering ply | BI01010001010000000000000515BI0100001192 | 169.46 | sqm |
| 15 | 15 | 5.8.5.2) Lintels, beams, plinth beams, girders, bressumers and cantilevers with wooden plank | BI01010001010000000000000515BI0100001193 | 51.92 | sqm |
| 16 | 16 | 5.8.4.2) Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply | BI01010001010000000000000515BI0100001194 | 39.26 | sqm |
| 17 | 17 | 5.8.6.2) Columns, Pillars, Piers, Abutments, Posts and Struts with wooden plank | BI01010001010000000000000515BI0100001195 | 25.16 | sqm |
| 18 | 18 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.\n5.19.4 Thermo-Mechanically Treated bars of grade Fe-500D or more | BI01010001010000000000000515BI0100001196 | 5640.6 | kg |
| 19 | 19 | 6 mm cement plaster in single layer finished with a floating coat of neat cement, curing and a thick coat of lime wash on top when dry on wall bearings for RCC slabs and beams complete.\ni) In cement mortar 1 : 3 ( 1 cement : 3 fine sand ) | BI01010001010000000000000515BI0100001197 | 286.9 | sqm |
| 20 | 20 | Providing structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required. | BI01010001010000000000000515BI0100001198 | 682 | kg |
| 21 | 21 | Finishing walls with water proofing cement paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :\nNew work ( two or more coats applied @ 3.84 kg/10 sqm)\n | BI01010001010000000000000515BI0100001199 | 60 | sqm |
| 22 | 22 | Finishing walls with acrylic smooth exterior paint of\nrequired shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : 12.30.1) New work ( two or more coats applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm\n | BI01010001010000000000000515BI0100001200 | 60 | sqm |
| 23 | 23 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:\nTwo or more coats on new work | BI01010001010000000000000515BI0100001201 | 100 | sqm |
| 24 | 24 | Providing and fixing G.I. pipes of Heavy class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge. \nA) External work. | BI01010001010000000000000515BI0100001202 | ||
| 25 | 25 | i) 150 mm dia. nominal bore | BI01010001010000000000000515BI0100001203 | 24 | m |
| 26 | 26 | ii) 100 mm dia. Nominal bore | BI01010001010000000000000515BI0100001204 | 12 | m |
| 27 | 27 | Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. | BI01010001010000000000000515BI0100001205 | ||
| 28 | 28 | i) 100 mm dia. | BI01010001010000000000000515BI0100001206 | 2 | No |
| 29 | 29 | ii). 150 mm dia | BI01010001010000000000000515BI0100001207 | 2 | No |
| 30 | 30 | Providing & fitting fixing of MS flange ( 8 mm wall thickness ) by welding with G.I. / MS pipe and placing position as per specification and the direction of the Engineer-in-charge.\ni). 150 mm dia | BI01010001010000000000000515BI0100001208 | 4 | No |
| 31 | 31 | Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge. | BI01010001010000000000000515BI0100001209 | ||
| 32 | 32 | v). 150 mm dia.\nA) PN - 1.6 | BI01010001010000000000000515BI0100001210 | 2 | No |
| 33 | 33 | vi). 100 mm dia.\nA) PN-1.6 | BI01010001010000000000000515BI0100001211 | 2 | No |
| 34 | 34 | 6 mm cement plaster of mix :\n12.4.1 In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) sqm | BI01010001010000000000000515BI0100001212 | 60 | sqm |
| 35 | 35 | Neat cement punning. | BI01010001010000000000000515BI0100001213 | 100 | sqm |
| 36 | 36 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 ( thickness to be specified by the manufacturer ) of approved make in all colours, shades of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1 : 3 ( 1 cement : 3 fine sand ) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade\ncomplete. | BI01010001010000000000000515BI0100001214 | 60 | sqm |
| 37 | 37 | Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. sheet duly stove enameled paint in white colour in front and gray colour on back with reflective border of 70 mm width and required message, letters and figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 2 Nos. 47 mm x 47 mm x 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawings and MoRD Technical Specification Clause 1701. | BI01010001010000000000000515BI0100001215 | 8.64 | sqm |
| 38 | 38 | SH (G-2): Pump House | BI01010001010000000000000515BI0100001216 | ||
| 39 | 39 | 6.12 Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete\n6.12.3.) In cement mortar 1:4 ( 1 cement : 4 fine sand ). | BI01010001010000000000000515BI0100001217 | 70.36 | Sqm |
| 40 | 40 | Reinforced cement concrete work in walls (any\nthickness), including attached pilasters, buttresses,plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-\n5.2.3) 1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001218 | 2.38 | Cum |
| 41 | 41 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-\n5.3.3) 1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001219 | 5.29 | Cum |
| 42 | 42 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.\n5.19.4 Thermo-Mechanically Treated bars of grade Fe-500D or more\n | BI01010001010000000000000515BI0100001220 | 1152 | Kg |
| 43 | 43 | Centering shuttering including struttings, propping etc. and removal of form work for | BI01010001010000000000000515BI0100001221 | ||
| 44 | 44 | i) Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply | BI01010001010000000000000515BI0100001222 | 10.24 | Sqm |
| 45 | 45 | ii) Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply | BI01010001010000000000000515BI0100001223 | 31.68 | sqm |
| 46 | 46 | iii) Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply | BI01010001010000000000000515BI0100001224 | 50.07 | Sqm |
| 47 | 47 | 8.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position \n8.1.2) Karai wood | BI01010001010000000000000515BI0100001225 | 0.3 | Cum |
| 48 | 48 | Providing and fixing panelled / or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked bright finished / black enamelled M.S butt hinges with necessary screws excluding panelling and or glazing, which will be paid for separately but including the wooden beading of 20 × 12 mm for fixing panelling and or glazing as per direction of Engineer-In-Charge\n a) Local Teak wood\n 8.5.1.1) 35 mm thick shutters | BI01010001010000000000000515BI0100001226 | 8.94 | Sqm |
| 49 | 49 | 8.46 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. \n8.46.2) Fixed to openings /wooden frames with rawl plugs screws etc. | BI01010001010000000000000515BI0100001227 | 44 | Kg |
| 50 | 50 | 8.51 Providing 40 × 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement : 3 fine sand : 6 graded stone aggregate 20mm nominal size)\n | BI01010001010000000000000515BI0100001228 | 28 | Nos |
| 51 | 51 | 8.61 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : \n8.61.4) 100 x 10 mm | BI01010001010000000000000515BI0100001229 | 18 | Nos |
| 52 | 52 | 8.64 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : \n8.64.2) 100 mm | BI01010001010000000000000515BI0100001230 | 8 | Nos. |
| 53 | 53 | 8.60 Providing and fixing ISI marked oxidised M.S.sliding door bolts with nuts and screws etc. complete\n8.60.2) 250 x 16 mm | BI01010001010000000000000515BI0100001231 | 2 | Nos. |
| 54 | 54 | 9.17 Providing and fixing M.S. round holding down bolts with nuts and wahser plates complete as per standard design | BI01010001010000000000000515BI0100001232 | 15.17 | Kg |
| 55 | 55 | Providing and laying cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded well burnt brick aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips etc. complete. \n10.9.2 40 mm thick with 20 mm well burnt brick aggregate | BI01010001010000000000000515BI0100001233 | 20.48 | Sqm |
| 56 | 56 | Providing and laying cement plaster skirting upto 300 mm height with cement mortar 1 : 3 ( 1 cement : 3 fine sand ) finished with a floating coat of neat cement including rounding of junctions etc. complete\n10.13.1) 18 mm thick | BI01010001010000000000000515BI0100001234 | 15.36 | Sqm |
| 57 | 57 | 12 mm cement plaster of mix\n12.1.4) In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) | BI01010001010000000000000515BI0100001235 | 91.56 | Sqm |
| 58 | 58 | 15 mm cement plaster on the rough side of single or half brick wall of mix:\n12.2.2 In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) | BI01010001010000000000000515BI0100001236 | 96.76 | Sqm |
| 59 | 59 | 6 mm cement plaster in single layer finished with a floating coat of neat cement, curing and a thick coat of lime wash on top when dry on wall bearings for RCC slabs and beams complete. \n12.6.1 In cement mortar 1 : 3 ( 1 cement : 3 fine sand ) | BI01010001010000000000000515BI0100001237 | 41.84 | Sqm |
| 60 | 60 | Neat cement punning. | BI01010001010000000000000515BI0100001238 | 14.4 | Sqm |
| 61 | 61 | Applying priming coats with primer of approved brand and maufacture, having low VOC (Volatile organic compound) content. [ Payment shall be made after submission of Test Certificate issued by the Manufacturer].\n12.34.3) With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre \n | BI01010001010000000000000515BI0100001239 | 158.34 | Sqm |
| 62 | 62 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:\nTwo or more coats on new work | BI01010001010000000000000515BI0100001240 | 35.734 | Sqm |
| 63 | 63 | Finishing walls with water proofing cement paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :\ni)New work ( two or more coats applied @ 3.84 kg/10 sqm)\n | BI01010001010000000000000515BI0100001241 | 158.34 | Sqm |
| 64 | 64 | Providing and fitting fixing of 6 feet x 4 feet x 1 inch (thickness) Gamair wood / plywood pannel board for fitting fixing of electrical items, in/c 2 nos MS angle post ( size 2 inch x 2 inch x 9 feet ), nuts & bolts etc. for irrection of the same by 1:1.5:3 cement concrete casting ( 1 feet x 1 feet x 2 feet) below the ground level and painting two or more coats & plastic paint as per specification and direction of the Engineer-in-charge | BI01010001010000000000000515BI0100001242 | 2 | Nos |
| 65 | 65 | Providing and fitting fixing with PVC insulated single core multistrand Copper cable conforming to IS : 694 for inter connection with all electrical equipments of the pannel board as per specification and direction of the Engineer-in-charge\nvii. 95 sqmm | BI01010001010000000000000515BI0100001243 | 30 | mtr. |
| 66 | 66 | Providing and fitting fixing of moving iron type, Range 0-500 V, 96 mm x 96 mm size AC Volt meter ( L & T / AE make) with selector switch as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge | BI01010001010000000000000515BI0100001244 | 2 | Nos |
| 67 | 67 | Providing and fitting fixing of moving iron type, Range 0-100/0200 amps, 96 mm x 96 mm size AC Amps meter direct reading type ( L & T / AE make) with selector switch and CT coil as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge | BI01010001010000000000000515BI0100001245 | 2 | Nos |
| 68 | 68 | Providing and fitting fixing of Fully Automatic Star Delta type Motor starter ( 3 ph. 50 Hz, 415V, in Steel Sheet Enclosures with Contractors and Timer etc. complete suitable for submersible Pump L & T, BCH, ABB make as per specification and direction of the Engineer-in-charge.\nii. 25 HP/18.5 kw Relay range within 13-21 + 10% | BI01010001010000000000000515BI0100001246 | 2 | Nos |
| 69 | 69 | Providing and fitting fixing steel sheet enclosed switch fuse unit (suitable for DIN fuses), triple pole with Neutral Link (TPN), 415/500 Volt, L & T / Havells / BCH make etc. complete as per specification and direction of the Engineer-in-charge\niii. 100 amps | BI01010001010000000000000515BI0100001247 | 2 | Nos |
| 70 | 70 | Providing and fitting fixing of Moulded Case Circuit Breaker (MCCB) of different Thermal release range , 415 + V, 50Hz (L & T, BCH, ABB make) as per specification and direction of the Engineer-in-charge.\nIv) 63-80 Amps | BI01010001010000000000000515BI0100001248 | 2 | No. |
| 71 | 71 | Providing and fitting fixing 3 phase indicating lamp fiited with panel board with three different colour lamps with batten holder complete as per specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001249 | 2 | Job |
| 72 | 72 | Providing and fitting fixing heavy duty box type (Resin filled) power factor correction capacitor L & T make etc. complete as per specification and direction of the Engineer-in-charge.\n i). 5-15 kVAr 440 V | BI01010001010000000000000515BI0100001250 | 2 | Job |
| 73 | 73 | Providing earthing with perforated 40 mm dia G.I. pipe (Medium class) ( 12 mm dia perforation ) , laying of 4 mm dia GI wire from earth electrode to panel, including excavating hole of 600 mm dia and refilling with Salt and Charcoal / coke in alternate layers of 300 mm , as per standard specification and direction of the Engineer-in-charge.\nii. for 3-phase connection with 4.00 mtr. Long G.I. pipe | BI01010001010000000000000515BI0100001251 | 2 | Nos |
| 74 | 74 | Providing & installation of 76.00 mtr head water lubricated submerssible pump with 3 Ph , 415 VAC motor with star delta connection along with PVC insulated 3 core flat Copper cable conforming to relevant IS code for submerssible motor with all necessary equipments and fittings as required upto the depth of 6.10 mtr (maximum) by GI pipe ( conforming to IS : 1239 medium class ) with tailpiece as required welded with GI flange in/c providing fitting fixing by necessary rubber washer, nuts & bolts, MS safety clamp etc. as per required size and making necessary electrical connection with main switch / starter with motor in/c commissioning & trial run as per direction of the Engineer-in-charge (each pump with motor shall consist of stainless steel impeller conforming to relevant BIS code. pump make : Duke/KSB/WPIL/Texmo/CRI ) (Pumpset, cable, G.I. pipe of medium class for column assembly etc. will be supplied by the agency at his cost and for main switch / starter payment will be done separately).\n\nii) 2500 GPH capacity with 65 mm dia G.I. pipe and 10 mm thick GI flange | BI01010001010000000000000515BI0100001252 | 2 | Nos |
| 75 | 75 | Extra for providing and mixing water proofing\nmaterial in cement concrete work in doses by weight of cement as per manufacturer's specification | BI01010001010000000000000515BI0100001253 | 440 | per 50kg of cement |
| 76 | 76 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 find : 6 graded well burnt brick aggregate 200 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. | BI01010001010000000000000515BI0100001254 | 22.24 | sqm |
| 77 | 77 | Half brick masonry work with first class bricks in foundation and plinth including cost of all materials as required complete:-\n6.10.3) In cement mortar 1:4 ( 1 cement : 4 fine sand ). | BI01010001010000000000000515BI0100001255 | 17.36 | sqm |
AI Tender Summary
Tender Timeline
Dec 03, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedDec 24, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 24, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender