Outsourcing Of Water Supply , Electric Supply , Air Conditioning And Misc E/M Installation At 12 Brd Af Stn Najafgarh Under Ge ( Af ) Tughlakabad , Out Sourcing Of Services For Running , Operation And Testing Of Equipment Of 11 Kv Main Receiving Stations And Other Sub Stations 12Brd Af Najafgarh With Various Equipments And Controlling Switches Gear As Listed Below Throughout The Day In ( 03 Shifts Of 8 Hrs Each ) By Empyoying One Electrician ( Skilled ) In Each Shift Including Sunday And Holiday . Necessary Cleaning , Grass Cutting & Maintenance Of Complete Substation , Equipments Including Surrounding Area Upto 10 Mtrs Of Outside Boundary Wall And Attending , Detecting Of Any Faults With In The 11 Kv Main Receiving Station And Other Sub Stations And Rectifying The Same On Emergency Basis As And When Required Including Attending /Rectifying Day To Day Electrical Complaints Married/Otm Accn Round The Clock Including Supply And Replacement Of Fuse , Unserviceable Nut , Bolt , Washer Etc And Toping Of Distilled Water And Electrolyte For Batteries And Maintaining Daily Log Sheet And Other Connected Documentssuch Earth Test Register Periodical Maintenance Register Etc Of Installations All As Directed By Engr In Charge . List Of Equipment And Control Panel:- ( A ) Step Down Transformer 11/433 Kv 500 Kva -02 Nos ( B ) Step Down Transformer 11/433 Kv 250 Kva -02 Nos ( C ) Step Down Transformer 11/433 Kv 160 Kva -01 No ( D ) Vcb 11 Kv With Bus Coupler - 07 +01 +01= 09 Nos ( E ) Lt Panel For Transformer - 04+02+02 = 08 Nos ( F ) Battery Bank - 01 Set ( G ) Internal Electric Fitting And Fixture ( H ) External Street Lights Of Bldg ( J ) Earthing System ( K ) Servo Voltage Stabilizer - 02 +01 +01= 04 Nos ( L ) Power Factor Panel - 01 No ( M ) Dg Set Of Capacity 125 Kva ( N ) Two Pole Structure With God-01 No , Min Wage Of Trademan As Per Prevailing Notification By The Govt Of India Or State Govt Whichever Is Higher . , Employees Provident Fund As Per Prevailing Notification By The Govt Of India . , Employees State Insurance Contribution As Per Prevailing Notification By The Govt Of India Or State Govt Whichever Is High . , Contribution Of Bonus As Per Prevailing Notification By The Govt Of India . , Over Head & Profit Of The Contractor On Srl No 1 . 01 To 1 . 04 , Labour Welfare Cess As Per Prevailing Notification By The Govt Of India . , Gst As Per Prevailing Notification By The Govt Of India . , Out Sourcing Of Services For Running , Operation And Testing Of Equipment Of 11 Kv Substation Outer Logistic Area Of 12 Brd Af Najafgarh Equipped With Various Equipments And Controlling Switches Gear As Listed Below In ( 02 Shifts Of 8 Hrs Each ) By Employing One Electrician ( Skilled ) In Each Shift Including Sunday And Holiday . Necessary Cleaning , Grass Cutting & Maintenance Of Complete Substation , Equipments Including Surrounding Area Upto 10 Mtrs Of Outside Boundary Wall And Attending , Detecting Of Any Faults Within The Substation And Rectifying The Same On Emergency Basis As And When Required Including Attending /Rectifying Day To Day Electrical Complaints Married/Otm Accn Round The Clock Including Supply And Replacement Of Fuses , Unserviceable Nuts , Bolts , Washer Etc And Maintaining Daily Log Sheet And Other Connected Document Such Earth Test Register Periodical Maintenance Register Etc Of Installations All As Directed By Engr In Charge . List Of Equipment And Control Panel:- ( A ) Step Down Transformer 11/433 Kv 300 Kva -01 No , S ( B ) Internal Electric Fitting And Fixture ( C ) External Street Lights Of Bldg ( D ) Earthing System ( E ) Power Factor Panel - 01 No ( F ) Lt Panel For Transformer - 02 No , S ( G ) Two Pole Structre With God-01 No , Min Wage Of Trademan As Per Prevailing Notification By The Govt Of India Or State Govt Whichever Is Higher . , Employees Provident Fund As Per Prevailing Notification By The Govt Of India . , Employees State Insurance Contribution As Per Prevailing Notification By The Govt Of India Or State Govt Whichever Is High . , Contribution Of Bonus As Per Prevailing Notification By The Govt Of India . , Over Head & Profit Of The Contractor On Srl No 2 . 01 To 2 . 04 , Labour Welfare Cess As Per Prevailing Notification By The Govt Of India . , Gst As Per Prevailing Notification By The Govt Of India . , Out Sourcing Of Services For Installations Of Booster Pumps , Officers Mess Pump , Guard Room Pump , Admin Area And Logistic Section Etc Submersible Pump , Mono Block Pump Chlorination Plant , Sewage Well , Stp And Outer Logistic Area Of 12 Brd Najafgarh Etc Including Supply And Distributions Of Water And Controlling Of Connecting Valve/Accessories In Three Shift By Employing Of One Pump Operator ( Skilled ) In Each Shift Timing Of Shift ( I . E . From 0600 Hrs To 1400 Hrs - I Shift , 1400 Hrs To 2200 Hrs - Iind Shift , 2200 Hrs To 0600 Hrs Iiird Shift ) Including Sunday & Holidays And Repair To Normal Defects As And When Required And Maintaining Log Sheet For Running Of Pumps And Duty Personnel Shall Be Responsible For Complete Fill Up Of The Over Head Reservoir /Sump During Duty Hours Including Cleaning The Pump Houses And Cutting Of Grasses Surrounding 10 Mtrs Areas All As Directed By Engr-In-Charge . , Min Wage Of Trademan As Per Prevailing Notification By The Govt Of India Or State Govt Whichever Is Higher . , Employees Provident Fund As Per Prevailing Notification By The Govt Of India . , Employees State Insurance Contribution As Per Prevailing Notification By The Govt Of India Or State Govt Whichever Is High . , Contribution Of Bonus As Per Prevailing Notification By The Govt Of India . , Over Head & Profit Of The Contractor On Srl No 3 . 01 To 3 . 04 , Labour Welfare Cess As Per Prevailing Notification By The Govt Of India . , Gst As Per Prevailing Notification By The Govt Of India . , Out Sourcing Of Services For Ac Plant At Ew Complex Af Najafgarh By Employing 02 Skilled Operator ( Ref Mech ) In 02 Shift Of 08 Hrs ( 01 Ref Mech Per Shift ) ( 1St Shift From 0600 Hours To 1400 Hours , 2Nd Shift 1400 Hours To 2200 Hours ) Including Necessary Cleaning , Grass Cutting & Maintenance Of Complete Substation Including Regular Maintenance Such As Daily Checking , Cleaning As Mentioned Below:- ( A ) Ac Plants Ew Complex :- ( A ) Ac Plant 3X80tr Capacity 2 Units Will Be In Operation And One Unit Will Be Stand By To Be Operation In 2 Shifts Per Day ( Shift Of 08 Hours ) All As Required And Directed By Engnr-In-Charge . ( B ) Regular Maintenance Such As Daily Checking Cleaning Monthly , Quarterly Half Yearly Maintenance Including Repair With Consumable Items Such As Cotton Waste , Grease , Fast Moving Parts Gland Packing Etc . The Ac Plant Comprising Of Compressor , Compressor Motor Condensers , Ahu Refrigerant Piping Control Pumps , Water Supply Lines , Cooling Tower , Drought Type , Electrical Panels Instrument Starters Strip Heaters And Provision Of Wiring All As Specified And Directed By Engr-In-Charge For Smooth And Efficient Performance Of Ac Plant To Achieve Desired Inside Condition . :- ( I ) Central Ac Plant 3 X 80 Ton , 2X80 Ton To Be Run At A Time And One Unit Stand By Comprising Of The Following :- ( Ii ) Mono Block Pumping Set 15 Hp = 04 Nos ( Iii ) Mono Block Pumping Set 3 Hp = 02 Nos ( Iv ) Ahu With 3 Phase 415 Volt Motor 10 Hp - 03 Nos ( Vi ) Cooling Tower With 3 Phase 415 Volt Motor 10 Hp - 01 No ( Vii ) 3 Phase 415 Volt Cubical Type Main Electric Control Panel Incoming And Outgoing Main Switch/Mcbs With Protection Devices Like Starter Inter Skilling System For Compressor Pumping Set Ahu And Cooling Tower . ( B ) D G Set ( A ) Operation And Regular Maintenance , Periodical Checking Of Dg Set 250 Kva-02 Nos Installed Near To Cent