Providing Fhtcs To 8 Panchayat In Gingee Block Under Xv Finance Commision Package 7
Tender Overview
Project Description
Providing Fhtcs To 8 Panchayat In Gingee Block Under Xv Finance Commision Package 7
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 05-Dec-2020 | Extension | Date | 08-Dec-2020 |
| 2 | 07-Dec-2020 | date extension | Date | 10-Dec-2020 |
| 3 | 09-Dec-2020 | Date Extension | Date | 16-Dec-2020 |
BOQ
| Name of Work: Providing Distribution Pipeline and FHTCS @ | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1.01 | Providing Distribution Pipeline and 54 FHTCS @Konakuttai Colony in Anaiyeri | |||
| 2 | 1.02 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd and Hard Gravelly Soil .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 940 | m | |
| 3 | 1.03 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 4 | 1.04 | a.63mm OD PVC Pipe 6 KSC | 940 | m | |
| 5 | 1.05 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 6 | 1.06 | a.63mm OD PVC Pipe 6 KSC | 940 | m | |
| 7 | 1.07 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 8 | 1.08 | a.63mm OD PVC Pipe 6 KSC | 940 | m | |
| 9 | 1.09 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 10 | 1.1 | 50mm PVC Bend page 12 ,sl.no-3 | 6 | Nos | |
| 11 | 1.11 | 63mm X 50mm PVC Threaded coupler page 10 SOR | 4 | Nos | |
| 12 | 1.12 | 63mm x50 mm PVC Tee IS 7834/1987 page 10 | 6 | Nos | |
| 13 | 1.13 | 63mm End cap page 12 sl.no 11 | 5 | Nos | |
| 14 | 1.14 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 15 | 1.15 | a.50mm GI pipe-page 25 sl.no 6 | 12 | m | |
| 16 | 1.16 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 17 | 1.17 | a.50mm GI Elbow page 25 sl.no 1 | 4 | nos | |
| 18 | 1.18 | b 80mm GI coupling page 25, sl.no 3 | 4 | nos | |
| 19 | 1.19 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 20 | 1.2 | a.50 mm dia Pipe | 12 | m | |
| 21 | 1.21 | Provision for gate value 50 mm - Pg No. 30, Clause 5.2 | 1 | Nos | |
| 22 | 1.22 | Provision for Jungle clearance | 1 | Nos | |
| 23 | 1.23 | Provision for FHTC's(6 meter length per FHTC with Post ) | 54 | Nos | |
| 24 | 1.24 | Fixing of Name Board including cost, painting, Lettering, installation etc. | 1 | Nos | |
| 25 | 1.25 | Photographic charges for taking photos in various stages before execution, during execution and after execution | 1 | Nos | |
| 26 | 1.26 | Providing Distribution Pipeline and 65FHTCS @AD Colony in Karai | |||
| 27 | 1.27 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd and Hard Gravelly Soil .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 1075 | m | |
| 28 | 1.28 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 29 | 1.29 | a.63mm OD PVC Pipe 6 KSC | 1075 | m | |
| 30 | 1.3 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 31 | 1.31 | a.63mm OD PVC Pipe 6 KSC | 1075 | m | |
| 32 | 1.32 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 33 | 1.33 | a.63mm OD PVC Pipe 6 KSC | 1075 | m | |
| 34 | 1.34 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 35 | 1.35 | 50mm PVC Bend page 12 ,sl.no-3 | 6 | Nos | |
| 36 | 1.36 | 63mm X 50mm PVC Threaded coupler page 10 SOR | 6 | Nos | |
| 37 | 1.37 | 63mm x50 mm PVC Tee IS 7834/1987 page 10 | 6 | Nos | |
| 38 | 1.38 | 63mm End cap page 12 sl.no 11 | 6 | Nos | |
| 39 | 1.39 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 40 | 1.4 | a.50mm GI pipe-page 25 sl.no 6 | 12 | m | |
| 41 | 1.41 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 42 | 1.42 | a.50mm GI Elbow page 25 sl.no 1 | 6 | nos | |
| 43 | 1.43 | b 80mm GI coupling page 25, sl.no 3 | 6 | nos | |
| 44 | 1.44 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 45 | 1.45 | a.50 mm dia Pipe | 12 | m | |
| 46 | 1.46 | Provision for gate value 50 mm - Pg No. 30, Clause 5.2 | 1 | Nos | |
| 47 | 1.47 | Provision for Jungle clearance | 1 | Nos | |
| 48 | 1.48 | Provision for FHTC's(6 meter length per FHTC with Post ) | 65 | Nos | |
| 49 | 1.49 | Fixing of Name Board including cost, painting, Lettering, installation etc. | 1 | Nos | |
| 50 | 1.5 | Photographic charges for taking photos in various stages before execution, during execution and after execution | 1 | Nos | |
| 51 | 1.51 | Providing Distribution Pipeline and 100 FHTCS @Pulivanthi Colony in Konalur | |||
| 52 | 1.52 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd and Hard Gravelly Soil .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 1330 | m | |
| 53 | 1.53 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 54 | 1.54 | a.63mm OD PVC Pipe 6 KSC | 1330 | m | |
| 55 | 1.55 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 56 | 1.56 | a.63mm OD PVC Pipe 6 KSC | 1330 | m | |
| 57 | 1.57 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 58 | 1.58 | a.63mm OD PVC Pipe 6 KSC | 1330 | m | |
| 59 | 1.59 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 60 | 1.6 | 50mm PVC Bend page 12 ,sl.no-3 | 10 | Nos | |
| 61 | 1.61 | 63mm X 50mm PVC Threaded coupler page 10 SOR | 10 | Nos | |
| 62 | 1.62 | 63mm x50 mm PVC Tee IS 7834/1987 page 10 | 10 | Nos | |
| 63 | 1.63 | 63mm End cap page 12 sl.no 11 | 8 | Nos | |
| 64 | 1.64 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 65 | 1.65 | a.50mm GI pipe-page 25 sl.no 6 | 12 | m | |
| 66 | 1.66 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 67 | 1.67 | a.50mm GI Elbow page 25 sl.no 1 | 8 | nos | |
| 68 | 1.68 | b 80mm GI coupling page 25, sl.no 3 | 8 | nos | |
| 69 | 1.69 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 70 | 1.7 | a.50 mm dia Pipe | 12 | m | |
| 71 | 1.71 | Provision for gate value 50 mm - Pg No. 30, Clause 5.2 | 1 | Nos | |
| 72 | 1.72 | Provision for Jungle clearance | 1 | Nos | |
| 73 | 1.73 | Provision for FHTC's(6 meter length per FHTC with Post ) | 100 | Nos | |
| 74 | 1.74 | Fixing of Name Board including cost, painting, Lettering, installation etc. | 1 | Nos | |
| 75 | 1.75 | Photographic charges for taking photos in various stages before execution, during execution and after execution | 1 | Nos | |
| 76 | 1.76 | Providing Distribution Pipeline and 31 FHTCS @ AD Colony in Mathurthirukkai | |||
| 77 | 1.77 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd and Hard Gravelly Soil .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 470 | m | |
| 78 | 1.78 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 79 | 1.79 | a.63mm OD PVC Pipe 6 KSC | 470 | m | |
| 80 | 1.8 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 81 | 1.81 | a.63mm OD PVC Pipe 6 KSC | 470 | m | |
| 82 | 1.82 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 83 | 1.83 | a.63mm OD PVC Pipe 6 KSC | 470 | m | |
| 84 | 1.84 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 85 | 1.85 | 50mm PVC Bend page 12 ,sl.no-3 | 10 | Nos | |
| 86 | 1.86 | 63mm X 50mm PVC Threaded coupler page 10 SOR | 10 | Nos | |
| 87 | 1.87 | 63mm x50 mm PVC Tee IS 7834/1987 page 10 | 10 | Nos | |
| 88 | 1.88 | 63mm End cap page 12 sl.no 11 | 8 | Nos | |
| 89 | 1.89 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 90 | 1.9 | a.50mm GI pipe-page 25 sl.no 6 | 12 | m | |
| 91 | 1.91 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 92 | 1.92 | a.50mm GI Elbow page 25 sl.no 1 | 8 | nos | |
| 93 | 1.93 | b 80mm GI coupling page 25, sl.no 3 | 8 | nos | |
| 94 | 1.94 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 95 | 1.95 | a.50 mm dia Pipe | 12 | m | |
| 96 | 1.96 | Provision for gate value 50 mm - Pg No. 30, Clause 5.2 | 1 | Nos | |
| 97 | 1.97 | Provision for Jungle clearance | 1 | Nos | |
| 98 | 1.98 | Provision for FHTC's(6 meter length per FHTC with Post ) | 31 | Nos | |
| 99 | 1.99 | Fixing of Name Board including cost, painting, Lettering, installation etc. | 1 | Nos | |
| 100 | 2 | Photographic charges for taking photos in various stages before execution, during execution and after execution | 1 | Nos | |
| 101 | 2.01 | Providing Distribution Pipeline and 21FHTCS @ AD Colony in Mavattampadi | |||
| 102 | 2.02 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd and Hard Gravelly Soil .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 368 | m | |
| 103 | 2.03 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 104 | 2.04 | a.63mm OD PVC Pipe 6 KSC | 368 | m | |
| 105 | 2.05 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 106 | 2.06 | a.63mm OD PVC Pipe 6 KSC | 368 | m | |
| 107 | 2.07 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 108 | 2.08 | a.63mm OD PVC Pipe 6 KSC | 368 | m | |
| 109 | 2.09 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 110 | 2.1 | 50mm PVC Bend page 12 ,sl.no-3 | 12 | Nos | |
| 111 | 2.11 | 63mm X 50mm PVC Threaded coupler page 10 SOR | 12 | Nos | |
| 112 | 2.12 | 63mm x50 mm PVC Tee IS 7834/1987 page 10 | 12 | Nos | |
| 113 | 2.13 | 63mm End cap page 12 sl.no 11 | 9 | Nos | |
| 114 | 2.14 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 115 | 2.15 | a.50mm GI pipe-page 25 sl.no 6 | 18 | m | |
| 116 | 2.16 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 117 | 2.17 | a.50mm GI Elbow page 25 sl.no 1 | 10 | nos | |
| 118 | 2.18 | b 80mm GI coupling page 25, sl.no 3 | 10 | nos | |
| 119 | 2.19 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 120 | 2.2 | a.50 mm dia Pipe | 18 | m | |
| 121 | 2.21 | Provision for gate value 50 mm - Pg No. 30, Clause 5.2 | 1 | Nos | |
| 122 | 2.22 | Provision for Jungle clearance | 1 | Nos | |
| 123 | 2.23 | Provision for FHTC's(6 meter length per FHTC with Post ) | 21 | Nos | |
| 124 | 2.24 | Fixing of Name Board including cost, painting, Lettering, installation etc. | 1 | Nos | |
| 125 | 2.25 | Photographic charges for taking photos in various stages before execution, during execution and after execution | 1 | Nos | |
| 126 | 2.26 | Providing Distribution Pipeline and 30 FHTCS @ Kommedu in Thenputhupattu | |||
| 127 | 2.27 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd and Hard Gravelly Soil .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 445 | m | |
| 128 | 2.28 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 129 | 2.29 | a.63mm OD PVC Pipe 6 KSC | 445 | m | |
| 130 | 2.3 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 131 | 2.31 | a.63mm OD PVC Pipe 6 KSC | 445 | m | |
| 132 | 2.32 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 133 | 2.33 | a.63mm OD PVC Pipe 6 KSC | 445 | m | |
| 134 | 2.34 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 135 | 2.35 | 50mm PVC Bend page 12 ,sl.no-3 | 10 | Nos | |
| 136 | 2.36 | 63mm X 50mm PVC Threaded coupler page 10 SOR | 10 | Nos | |
| 137 | 2.37 | 63mm x50 mm PVC Tee IS 7834/1987 page 10 | 10 | Nos | |
| 138 | 2.38 | 63mm End cap page 12 sl.no 11 | 6 | Nos | |
| 139 | 2.39 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 140 | 2.4 | a.50mm GI pipe-page 25 sl.no 6 | 12 | m | |
| 141 | 2.41 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 142 | 2.42 | a.50mm GI Elbow page 25 sl.no 1 | 8 | nos | |
| 143 | 2.43 | b 80mm GI coupling page 25, sl.no 3 | 8 | nos | |
| 144 | 2.44 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 145 | 2.45 | a.50 mm dia Pipe | 12 | m | |
| 146 | 2.46 | Provision for gate value 50 mm - Pg No. 30, Clause 5.2 | 1 | Nos | |
| 147 | 2.47 | Provision for Jungle clearance | 1 | Nos | |
| 148 | 2.48 | Provision for FHTC's(6 meter length per FHTC with Post ) | 30 | Nos | |
| 149 | 2.49 | Fixing of Name Board including cost, painting, Lettering, installation etc. | 1 | Nos | |
| 150 | 2.5 | Photographic charges for taking photos in various stages before execution, during execution and after execution | 1 | Nos | |
| 151 | 2.51 | Providing Distribution Pipeline and 47FHTCS @ Thiruvathikunnam | |||
| 152 | 2.52 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd and Hard Gravelly Soil .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 730 | m | |
| 153 | 2.53 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 154 | 2.54 | a.63mm OD PVC Pipe 6 KSC | 730 | m | |
| 155 | 2.55 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 156 | 2.56 | a.63mm OD PVC Pipe 6 KSC | 730 | m | |
| 157 | 2.57 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 158 | 2.58 | a.63mm OD PVC Pipe 6 KSC | 730 | m | |
| 159 | 2.59 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 160 | 2.6 | 50mm PVC Bend page 12 ,sl.no-3 | 10 | Nos | |
| 161 | 2.61 | 63mm X 50mm PVC Threaded coupler page 10 SOR | 10 | Nos | |
| 162 | 2.62 | 63mm x50 mm PVC Tee IS 7834/1987 page 10 | 10 | Nos | |
| 163 | 2.63 | 63mm End cap page 12 sl.no 11 | 6 | Nos | |
| 164 | 2.64 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 165 | 2.65 | a.50mm GI pipe-page 25 sl.no 6 | 12 | m | |
| 166 | 2.66 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 167 | 2.67 | a.50mm GI Elbow page 25 sl.no 1 | 8 | nos | |
| 168 | 2.68 | b 80mm GI coupling page 25, sl.no 3 | 8 | nos | |
| 169 | 2.69 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 170 | 2.7 | a.50 mm dia Pipe | 12 | m | |
| 171 | 2.71 | Provision for gate value 50 mm - Pg No. 30, Clause 5.2 | 1 | Nos | |
| 172 | 2.72 | Provision for Jungle clearance | 1 | Nos | |
| 173 | 2.73 | Provision for FHTC's(6 meter length per FHTC with Post ) | 47 | Nos | |
| 174 | 2.74 | Fixing of Name Board including cost, painting, Lettering, installation etc. | 1 | Nos | |
| 175 | 2.75 | Photographic charges for taking photos in various stages before execution, during execution and after execution | 1 | Nos | |
| 176 | 2.76 | Providing Distribution Pipeline and 21 FHTCS @ Uranithangal | |||
| 177 | 2.77 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd and Hard Gravelly Soil .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 425 | m | |
| 178 | 2.78 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 179 | 2.79 | a.63mm OD PVC Pipe 6 KSC | 425 | m | |
| 180 | 2.8 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 181 | 2.81 | a.63mm OD PVC Pipe 6 KSC | 425 | m | |
| 182 | 2.82 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 183 | 2.83 | a.63mm OD PVC Pipe 6 KSC | 425 | m | |
| 184 | 2.84 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 185 | 2.85 | 50mm PVC Bend page 12 ,sl.no-3 | 10 | Nos | |
| 186 | 2.86 | 63mm X 50mm PVC Threaded coupler page 10 SOR | 10 | Nos | |
| 187 | 2.87 | 63mm x50 mm PVC Tee IS 7834/1987 page 10 | 10 | Nos | |
| 188 | 2.88 | 63mm End cap page 12 sl.no 11 | 6 | Nos | |
| 189 | 2.89 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 190 | 2.9 | a.50mm GI pipe-page 25 sl.no 6 | 12 | m | |
| 191 | 2.91 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 192 | 2.92 | a.50mm GI Elbow page 25 sl.no 1 | 6 | nos | |
| 193 | 2.93 | b 80mm GI coupling page 25, sl.no 3 | 6 | nos | |
| 194 | 2.94 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 195 | 2.95 | a.50 mm dia Pipe | 12 | m | |
| 196 | 2.96 | Provision for gate value 50 mm - Pg No. 30, Clause 5.2 | 1 | Nos | |
| 197 | 2.97 | Provision for Jungle clearance | 1 | Nos | |
| 198 | 2.98 | Provision for FHTC's(6 meter length per FHTC with Post ) | 21 | Nos | |
| 199 | 2.99 | Fixing of Name Board including cost, painting, Lettering, installation etc. | 1 | Nos | |
| 200 | 3 | Photographic charges for taking photos in various stages before execution, during execution and after execution | 1 | Nos | |
| 201 | 3.1 | GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column \"BB\" for all works in this package}\n | BI01010001010000000000000515BI01000011120 | 1 | GST Amount (in Rupees) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender