Kiifb Kiidc Thalassery Heritage Project Phase 1 Cultural Circuit Kakkulangara Mosque Conservation And Streetscaping Of Kakkulangara Mosque Valapattanam Kannur District Heritage Project Works, Valapattanam Kannur-Kerala

Kerala Irrigation Infrastructure Development Corporation Limited-KIIDC has published Kiifb Kiidc Thalassery Heritage Project Phase 1 Cultural Circuit Kakkulangara Mosque Conservation And Streetscaping Of Kakkulangara Mosque Valapattanam Kannur District Heritage Project Works. Submission Date for this Tender is 15-12-2020. Road Work Tenders in Valapattanam Kannur Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

26128778
Kiifb Kiidc Thalassery Heritage Project Phase 1 Cultural Circuit Kakkulangara Mosque Conservation And Streetscaping Of Kakkulangara Mosque Valapattanam Kannur District Heritage Project Works
Open Tender
Indian
Kerala
Valapattanam Kannur
15-12-2020

Tender Details

Kiifb Kiidc Thalassery Heritage Project Phase 1 Cultural Circuit Kakkulangara Mosque Conservation And Streetscaping Of Kakkulangara Mosque Valapattanam Kannur District Heritage Project Works

Key Value

Document Fees
INR 2950 /-
EMD
INR 50000.0 /-
Tender Value
INR 77.55 Lakhs /-

BOQ Items

Work Name : KIIFB PROJECT-THALASSERY HERITAGE PROJECT- PHASE 1 - Cultural Circuit- Kakkulangara Mosque (Conservation and Streetscaping of Kakkulangara Mosque, Valapattanam, Kannur District)
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Appendix A: Outdoor clearing BI01010001010000000000000515BI0100001113
2 1.01 2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared BI01010001010000000000000515BI0100001114 1250 sqm
3 1.02 2.1.1 : Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil BI01010001010000000000000515BI0100001115 600 sqm
4 1.03 15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar BI01010001010000000000000515BI0100001116 60.85 cum
5 1.04 15.2.1 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) BI01010001010000000000000515BI0100001117 14.04 cum
6 1.05 15.9.2 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar BI01010001010000000000000515BI0100001118 20.84 cum
7 2 Appendix B: Conservation of mosque BI01010001010000000000000515BI0100001119
8 2.01 14.85 : Taking out existing wooden door shutter, repair by cutting, painting etc. andrefixing of repaired door shutters to existing door frames, including replacementof hinges with screws, etc. as required, all complete as per the direction of theEngineer-in-charge. BI01010001010000000000000515BI0100001120 114.24 sqm
9 2.02 od221410/2019_2020 : Polishing the doors and windows with malamine polish including all charges etc. complete. BI01010001010000000000000515BI0100001121 228.48 sqm
10 2.03 13.31.1 : Pointing on brick work or brick flooring with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled /Struck or weathered pointing BI01010001010000000000000515BI0100001122 122.461 sqm
11 2.04 13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm BI01010001010000000000000515BI0100001123 2688 sqm
12 2.05 od173251/2020_2021 : Setting up of a document with Photographs of site before and after the work. The item includes developing of a photographs to a size of 6"x4" and preparing a booklet. BI01010001010000000000000515BI0100001124 20 each
13 3 Appendix C: Pathway BI01010001010000000000000515BI0100001125
14 3.01 16.1 : Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. BI01010001010000000000000515BI0100001126 266.412 sqm
15 3.02 16.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 BI01010001010000000000000515BI0100001127 53.29 cum
16 3.03 50.6.7.1 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc. BI01010001010000000000000515BI0100001128 53.29 cum
17 4 Appendix D: Conservation of Kulappura BI01010001010000000000000515BI0100001129
18 4.01 15.14.1 : Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead:Of sectional area 40 square centimetres and above BI01010001010000000000000515BI0100001130 0.4 cum
19 4.02 od173265/2020_2021 : 50.9.13.2 (modified)Supplying and fixing second class teak wood wood wrought and put up for roof members including cost and conveyance of materials etc. complete. BI01010001010000000000000515BI0100001131 0.352 cum
20 4.03 od173266/2020_2021 : 50.9.14.2 (modified) Supplying and fixing second class teak wood reapers of size 50x25 mm with wire nails including cost and conveyance of materials etc. complete. BI01010001010000000000000515BI0100001132 0.139 cum
21 4.04 12.48 : Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) BI01010001010000000000000515BI0100001133 44.201 sqm
22 4.05 12.49 : Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ). BI01010001010000000000000515BI0100001134 8.5 metre
23 4.06 od45802/2020_2021 : Providing & fixing on roof pressed clay ceiling tiles 30x25cm size of 20 mm nominal thickness and of approved size and as per approved pattern BI01010001010000000000000515BI0100001135 44.201 sqm
24 5 Appendix E: Gallery BI01010001010000000000000515BI0100001136
25 5.01 2.1.1 : Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil BI01010001010000000000000515BI0100001137 225 sqm
26 5.02 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil BI01010001010000000000000515BI0100001138 225.916 cum
27 5.03 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) BI01010001010000000000000515BI0100001139 27.809 cum
28 5.04 5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size BI01010001010000000000000515BI0100001140 24.837 cum
29 5.05 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more BI01010001010000000000000515BI0100001141 2235.06 kilogram
30 5.06 5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. BI01010001010000000000000515BI0100001142 51.451 sqm
31 5.07 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete BI01010001010000000000000515BI0100001143 39.442 sqm
32 5.08 7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) BI01010001010000000000000515BI0100001144 48.808 cum
33 5.09 2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. BI01010001010000000000000515BI0100001145 71.922 cum
34 5.1 50.6.7.3 : Laterate masonry with neatly dressed laterate stone of size 40x20x15 cm or nearest size in cement mortar 1:6 for superstructure above floor two level upto floor five level including all cost of materials, labour charges etc. BI01010001010000000000000515BI0100001146 105.654 cum
35 5.11 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) BI01010001010000000000000515BI0100001147 818.87 sqm
36 5.12 13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm BI01010001010000000000000515BI0100001148 818.87 sqm
37 5.13 10.16.2 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes BI01010001010000000000000515BI0100001149 11565 kg
38 5.14 12.48 : Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) BI01010001010000000000000515BI0100001150 385.5 sqm
39 5.15 12.49 : Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ). BI01010001010000000000000515BI0100001151 40 metre
40 5.16 od45802/2020_2021 : Providing & fixing on roof pressed clay ceiling tiles 30x25cm size of 20 mm nominal thickness and of approved size and as per approved pattern BI01010001010000000000000515BI0100001152 385.5 sqm
41 5.17 9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood BI01010001010000000000000515BI0100001153 2.523 cum
42 5.18 9.5.1.1 : Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak wood35 mm thick shutters BI01010001010000000000000515BI0100001154 37.64 sqm
43 5.19 9.7.1 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood BI01010001010000000000000515BI0100001155 23.19 sqm
44 5.2 9.7.7.2 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:5.5mm thick glass pane BI01010001010000000000000515BI0100001156 5.087 sqm
45 5.21 od45803/2020_2021 : Providing and laying Terracota tiles (thickness to be specified by the manufacturer), 1:3 (1 Cement :3Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. BI01010001010000000000000515BI0100001157 122 sqm
46 5.22 9.141 : Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (±0.2mm), made out of single piece extruded PVC profile, with mitred cut joints and with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm, including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8x100 mm long anchor fasteners complete, all as per manufacturer's specification and direction of Engineer-in--charge. BI01010001010000000000000515BI0100001158 17.4 metre
47 5.23 9.142.1 : 35 mm thick factory made Solid panel PVC Door shutter, made out of single piece extruded solid PVC ( ±0.2 mm) thick, having styles & rails (except lock rail ) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinges side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm x 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm x 100 mm of cross section size 35 mm x 17 mm s 1 mm at each corner. Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x 35 mm x 35 mm, out of which 95 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer's specification and direction of Engineer-in-charge.Non decorative finish (matt finish) BI01010001010000000000000515BI0100001159 5.041 sqm
48 5.24 11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. BI01010001010000000000000515BI0100001160 80.815 sqm
49 5.25 11.37 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. BI01010001010000000000000515BI0100001161 38.121 sqm
50 6 Appendix F: Plumbing & Miscellaneous BI01010001010000000000000515BI0100001162
51 6.01 50.18.7.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge 20 mm dia 10 Kgf/cm2- Internal work - Exposed on wall BI01010001010000000000000515BI0100001163 50 metre
52 6.02 50.18.7.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall BI01010001010000000000000515BI0100001164 50 metre
53 6.03 50.18.7.4.2 : Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall BI01010001010000000000000515BI0100001165 50 metre
54 6.04 50.18.7.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall BI01010001010000000000000515BI0100001166 30 metre
55 6.05 od173270/2020_2021 : Providing and fixing (UN0002) Universal Angle Cock of superior quality Jaguar or equivalent<br> BI01010001010000000000000515BI0100001167 12 each
56 6.06 od173271/2020_2021 : Providing and fixing (579 CHR) HEALTH FAUCET of Superior quality Jaguar or equivalent brand<br> BI01010001010000000000000515BI0100001168 6 each
57 6.07 od173272/2020_2021 : Providing and fixing (089 ALD c) stop cock of superior quality 15 mm nominal bore Jaguar or equivalent brand<br> BI01010001010000000000000515BI0100001169 12 each
58 6.08 od173273/2020_2021 : Providing and fixing superior quality brand CP Soap Dish Holder concealed fitting arrangements, weighing not less than 106 gms<br> BI01010001010000000000000515BI0100001170 12 each
59 6.09 od173274/2020_2021 : Providing and fixing C.P. brass bib cock of superior quality Jaguar or equivalent brand<br>conforming to IS:8931. 15 mm nominal bore BI01010001010000000000000515BI0100001171 12 each
60 6.1 od173282/2020_2021 : Supply & Fixing square Cockroach proof Traps with CP Gratings. Unloading materials supplied at site and storing it in safe place provided in the site. (Make: ACO/SGS ) BI01010001010000000000000515BI0100001172 6 each
61 6.11 od173275/2020_2021 : Providing and fixing superior quality white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.l.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid JAQUAR LYS-WHT-38851S300UFSM or Equivalent <br>approved municipal design complete, including painting of fittings and brackets, cutting and making <br>good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid BI01010001010000000000000515BI0100001173 3 each
62 6.12 17.4.2 : Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern BI01010001010000000000000515BI0100001174 2 each
63 6.13 od173276/2020_2021 : Providing and fixing Cavier SS towel rod complete with brackets fixed to wooden<br>cleats with CP brass screws with concealed fitting arrangement of approved quality and colour. JAQUAR<br>ACN-1111SM or Equivalent<br> BI01010001010000000000000515BI0100001175 6 each
64 6.14 od173277/2020_2021 : Providing and fixing superior quality White Vitreous China Wash basin size 630x450mm with a pair of 15 mm C. P. brass pillar taps with C.I. brackets, 32 mm waste pipe of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required ect. complete: JAQUAR ARS-WHT-39803 or Equivalent<br>"<br> BI01010001010000000000000515BI0100001176 6 each
65 6.15 51.19.ST4 : Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately)<br>\n4. 35 to 50 flush capacity BI01010001010000000000000515BI0100001177 1 each
66 6.16 19.32.1 : Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 BI01010001010000000000000515BI0100001178 1 each
67 6.17 50.6.7.2 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. BI01010001010000000000000515BI0100001179 1 cum
68 6.18 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) BI01010001010000000000000515BI0100001180 5 sqm
69 6.19 14.67.2 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:Old work ( one or more coats applied @ 0.83 ltr/10 sqm) BI01010001010000000000000515BI0100001181 456.55 sqm
70 6.2 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil BI01010001010000000000000515BI0100001182 11.611 cum
71 6.21 4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) BI01010001010000000000000515BI0100001183 11.611 cum
72 6.22 od179542/2020_2021 : Supply and providing suitable size foundation bolts and nuts with washers for lamp poles, bollards, outdoor lamp fittings etc. BI01010001010000000000000515BI0100001184 215 kilogram
73 7 Appendix J: Landscaping BI01010001010000000000000515BI0100001185
74 7.01 od94017/2020_2021 : Supplying and planting of approved shrubs at required spacing as shown in drawing. Rate shall include cost of plants soil work,manure and fertilizers used in top dressing, chemical and machanical pest control, staking and maintaining the planting till it is handed over from the date of planting labour charges, pest control operating etc. (9)Oleander tall BI01010001010000000000000515BI0100001186 30 each
75 7.02 od94018/2020_2021 : Supplying and planting of approved shrubs at required spacing as shown in drawing. Rate shall include cost of plants soil work,manure and fertilizers used in top dressing, chemical and machanical pest control, staking and maintaining the planting till it is handed over from the date of planting labour charges, pest control operating etc. (1)Aglonema BI01010001010000000000000515BI0100001187 50 each
76 7.03 od94019/2020_2021 : Supplying and planting of approved palms to a specified locations as shown in drawing. Rate shall include pitting, soil work, staking and planting of palms. sapling and for providing a pit size 75 x 75 x 75 cm. (4)Red Palms 1.2m Height BI01010001010000000000000515BI0100001188 50 each
77 7.04 od94020/2020_2021 : Supplying and planting of approved specimen plants to a specified locations as shown in drawing. Cost of plants, soil work inclusive of red soil, sand and manure mix staking and planting of trees sapling, replacement of dead trees and for providing a pit size 75 x 75 x 75 cm and maintainance till the competion of project work.(6)Ficus Panda BI01010001010000000000000515BI0100001189 10 each
78 7.05 od94021/2020_2021 : Supplying and planting of approved trees species of a height 2.0m to 2.5m, at the specified location as shown in the drawing.Rate shall include Cost of plants, soil work inclusive of red soil, sand and manure mix staking and planting of trees sapling, replacement of dead trees and for providing a pit size 75 x 75 x 75 cm and maintainance till the competion of project work.( 1).Plumeria Alba BI01010001010000000000000515BI0100001190 5 each
79 7.06 od94022/2020_2021 : supplying and laying the paspullam over the leveled and prepared surface.the rate shall include the cost of grass mat input manure and fertilizers used periodically for top dressing ,chemical and mechanical pest control and all post planting maintanance procedure complete till the complection of project 1)Buffallo grass BI01010001010000000000000515BI0100001191 200 sqm
80 7.07 15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar BI01010001010000000000000515BI0100001192 31.8 cum
81 7.08 50.6.7.2 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. BI01010001010000000000000515BI0100001193 38.25 cum
82 7.09 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) BI01010001010000000000000515BI0100001194 159 sqm
83 8 Appendix - I - Electrification BI01010001010000000000000515BI0100001195
84 8.01 1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC\ninsulated copper conductor single core cable in surface / recessed medium class PVC conduit,\nwith modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS\nPVC insulated copper conductor single core cable etc as required.Group C BI01010001010000000000000515BI0100001196 5 point
85 8.02 1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C BI01010001010000000000000515BI0100001197 1 point
86 8.03 1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings). BI01010001010000000000000515BI0100001198 2 each
87 8.04 1.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. BI01010001010000000000000515BI0100001199 1 each
88 8.05 1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) BI01010001010000000000000515BI0100001200 2 each
89 8.06 1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch BI01010001010000000000000515BI0100001201 4 each
90 8.07 1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet BI01010001010000000000000515BI0100001202 4 each
91 8.08 1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required. BI01010001010000000000000515BI0100001203 11 each
92 8.09 1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). BI01010001010000000000000515BI0100001204 2 each
93 8.1 od130173/2020_2021 : Supply, Installation, Testing and commissioning of 6W ceiling speakers with perforated metal grille with line matching transformer suitable for 4 ohm impedence 200mm dia LBD 0606/10 BI01010001010000000000000515BI0100001205 4 no
94 8.11 90.4.9 : Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required. BI01010001010000000000000515BI0100001206 4 each
95 8.12 od130174/2020_2021 : Supply, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.300/305mm light duty BI01010001010000000000000515BI0100001207 4 each
96 8.13 90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. BI01010001010000000000000515BI0100001208 7 each
97 8.14 1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. BI01010001010000000000000515BI0100001209 7 each
98 8.15 od130176/2020_2021 : SITC of decorative outdoor wall light with 13.5 W Cool Daylight (CDL), Excellent CRI&gt;80 , IP54. ( Havells ELLIPSE NEO 13.5 W HEXA or equivalent ) BI01010001010000000000000515BI0100001210 16 each
99 8.16 od130180/2020_2021 : SITC of Environment friendly, energy efficient, aesthetically designed, surface ornamented with rings, moulded&lt;br&gt;body, wall/ceiling light LED fixture with diffuser to give glare free light, 5 W LED 6000 K.(Havells JOY RING or equivalent) BI01010001010000000000000515BI0100001211 6 each
100 8.17 od130181/2020_2021 : SITC of Decorative, wall mounting fixture, in durable plastic body &amp; designer mesh in gold finish suitable for 9 W LED lamp. (Havells Glaze or equivalent) BI01010001010000000000000515BI0100001212 24 each
101 8.18 od130182/2020_2021 : SITC of step light with 2W LED, 8.4 &times; 8.4 &times; 4.4 cm, aluminium base material (Philips Steplight or equivalent) BI01010001010000000000000515BI0100001213 13 each
102 8.19 od130183/2020_2021 : SITC of track accessories for housing track light, 1 meter linear length (Havells 1MTR3PHASETRACKTSWHT or equivalent) BI01010001010000000000000515BI0100001214 9 each
103 8.2 od130184/2020_2021 : SITC of track light With the high power 15W LED offers various luminous intensity levels from 1500-3500 Lumen Suitable for 3 circuit-4 wire universal tracks.(Havells CYLINDROTS15WLED830S3WIRE38DWHT or equivalent) BI01010001010000000000000515BI0100001215 27 each
104 8.21 od130185/2020_2021 : SITC of 12W LED hanging light with extruded aluminium housing with microtexture powder coating. (Wipro Halo Plus --LD99-151-XXX57PMWH or equivalent. BI01010001010000000000000515BI0100001216 5 each
105 8.22 od130186/2020_2021 : Supply Conveyance, installation, testing and commissioning of LED spike light with die cast aluminium housing with warm white COB LED reflector with IP65 protection. 9W LED (Bajaj SPYKZ or equivalent) BI01010001010000000000000515BI0100001217 12 each
106 8.23 od130187/2020_2021 : SITC of New generation, energy saving, environmental friendly, long life aesthetically designed aluminium bollard landscape luminaire for diffused lighting with high power LED as light source. 8W, 1m height, IP 65.( Havells BAMBOOBL8WLED757PSYMTOPCM or equivalent) BI01010001010000000000000515BI0100001218 43 each
107 8.24 od130188/2020_2021 : Supply Conveyance, installation, testing and commissioning of 5W batten integrated sleek extruded aluminium LED channel with white acrylic cover as mirror light. (Bajaj BCLSB05 NW or equivalent) BI01010001010000000000000515BI0100001219 4 each
108 8.25 od130189/2020_2021 : SITC of Recess mounted 20W LED wall washers, tilted 70&deg; outwards and swivels 360&deg; to offer best illumination on the wall and retail displays.( Havells SPARKLEPROSNOOTDLR20W830MOD30DWHT or equivalent) BI01010001010000000000000515BI0100001220 24 each
109 8.26 od130190/2020_2021 : Supply Conveyance, installation, testing and commissioning of 30W flood light with high pressure die cast aluminium and IP 65 protection. (Bajaj MAGNUM or equivalent) BI01010001010000000000000515BI0100001221 9 each
110 8.27 od130191/2020_2021 : Supply Conveyance, installation, testing and commissioning of environment friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminare comprising of high brightness LEDs. 10W 6000K with IP65 protection. (Havells Endura Rugby Neo or equivalent) BI01010001010000000000000515BI0100001222 16 each
111 8.28 90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required BI01010001010000000000000515BI0100001223 1 each
112 8.29 2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door BI01010001010000000000000515BI0100001224 4 each
113 8.3 2.3.1 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door BI01010001010000000000000515BI0100001225 1 each
114 8.31 od130196/2020_2021 : SITC Of feeder pillar complete with the following accessories. Incomer: 40A, DP&lt;br&gt;Isolator. 40A, DP, RCCB, 100mA. Timer control with contactor. Auto/ Manual&lt;br&gt;switch. Outgoing: 10A, SP MCB - 4 Nos. BI01010001010000000000000515BI0100001226 1 each
115 8.32 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole BI01010001010000000000000515BI0100001227 35 each
116 8.33 2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole BI01010001010000000000000515BI0100001228 5 each
117 8.34 2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual\ncurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps BI01010001010000000000000515BI0100001229 4 each
118 8.35 2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual\ncurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps BI01010001010000000000000515BI0100001230 1 each
119 8.36 2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual \n current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps BI01010001010000000000000515BI0100001231 1 each
120 8.37 2.10.5 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral BI01010001010000000000000515BI0100001232 1 each
121 8.38 1.12 : Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single corecable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulatedcopper conductor single core cable for loop earthing as required. BI01010001010000000000000515BI0100001233 25 metre
122 8.39 1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire BI01010001010000000000000515BI0100001234 175 metre
123 8.4 1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm BI01010001010000000000000515BI0100001235 100 metre
124 8.41 90.12.1.3 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). BI01010001010000000000000515BI0100001236 375 metre
125 8.42 90.12.7.3 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. BI01010001010000000000000515BI0100001237 25 metre
126 8.43 90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. BI01010001010000000000000515BI0100001238 10 metre
127 8.44 od130208/2020_2021 : Supply of 2.5sqmm 2core PVC/XLPE insulated armoured copper conductor cable for working voltage upto and including 1100V conforming to IS1584/Part I/1988 for PVC &amp; IS7098 PartI for XLPE BI01010001010000000000000515BI0100001239 250 metre
128 8.45 9.1.2 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.2 X 10 sq. mm (19mm) BI01010001010000000000000515BI0100001240 20 set
129 8.46 9.3.29 : Supplying and making straight through joint with cast resin compound including ferrules and\nother jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm BI01010001010000000000000515BI0100001241 2 each
130 8.47 7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm BI01010001010000000000000515BI0100001242 200 metre
131 8.48 90.12.10.2 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation BI01010001010000000000000515BI0100001243 600 metre
132 8.49 90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required BI01010001010000000000000515BI0100001244 600 metre
133 8.5 5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. BI01010001010000000000000515BI0100001245 2 set
134 8.51 5.13 : Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. BI01010001010000000000000515BI0100001246 30 metre
135 8.52 90.16.3.9 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run) BI01010001010000000000000515BI0100001247 1 metre
136 8.53 od130216/2020_2021 : Supply &amp; installation of dust and vermin proof, 3 Phase Syntex Meter Board GS-MB-6535(size 760x450x260x) and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as required. BI01010001010000000000000515BI0100001248 1 each
137 8.54 2.1.2 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N BI01010001010000000000000515BI0100001249 1 each
138 8.55 od130217/2020_2021 : Supply and fixing 63A HRC fuse base with fuse link in the existing meter board. BI01010001010000000000000515BI0100001250 3 each
139 8.56 od130218/2020_2021 : Supply and fixing 63 A, 415 V, 2 way neutral link mounted on DMC/ SMC base in the existing meter board. BI01010001010000000000000515BI0100001251 1 each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail