Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 04-12-2020 | Extend Time | Date | 07-12-2020 |
| Name of Work:Providing LWSS to Kotlagopalur in Tehsil Banjar, District Kullu HP. (SH: Installations / testing of pumping machinery, Including Providing installing and assembling of Allied accessories of Pumping machinery.) (Balance Work) Estimated Cost :- 1319466/- EMD :- 26389 /- Time :- 2 months | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | PUMPING MACHINERY\nRaw water stage:\nInstallation of suitable raw water submersible pumpset type Amarex NF65/70, 3KW/4HP capable of handling 6000 PPM turbidity of KSB make conforming to latest BIS code. The pump shall be fitted with single vane impeller of suitable alloy for handling raw water as per IS 5669-1970 having oil/grease packed bearings and stainless steel shaft, wound stator on motor side with shaft protection sleeves on pump side ensuring better life for shaft . The impeller of pump shall be directly mounted on extended submersible sq cage motor shaft conf to BIS 9238-1979 with up to date amendments of 1450 / 2900 (N) RPM, totally dust and weather proof with detach able pump casing for easy inspection with double mechanical seal, grease/ oil lubricated bearings and provided with stainless steel thrust bearing plate to withstand vertical loads with minimum wear and tear,It should be fitted with device to take up expanion of water on heating of motor & suitable for operation on 415 +/- 10% volts 3 Phase 50 C/S AC supply. The power of motor should be at least 10% in excess of maximum power required by the pump in complete operating range with mounting stand/ duck foot bend, steel guide wire with mounting hook, lowering chain and standard accessories as supplied by the manufacturers complete, suitable for fulfilling the following requirements:- | BI01010001010000000000000515BI0100001114 | 2 | Set |
| 2 | 1.01 | PUMP OPERATING CONDITIONS | BI01010001010000000000000515BI0100001115 | ||
| 3 | 1.02 | Discharge: 31m^3/hr for each pump set | BI01010001010000000000000515BI0100001116 | ||
| 4 | 1.03 | Total head in Mts. 13 mtrs. | BI01010001010000000000000515BI0100001117 | ||
| 5 | 1.04 | Length of R/Main 100 Rmtr. | BI01010001010000000000000515BI0100001118 | ||
| 6 | 1.05 | Dia of R/Main 100 mm | BI01010001010000000000000515BI0100001119 | ||
| 7 | 1.06 | Pumping hours 8 Hours | BI01010001010000000000000515BI0100001120 | ||
| 8 | 1.07 | Limits of total head in which the pump/ motor is reqd. to operate. (+)10% & (-) 15% | BI01010001010000000000000515BI0100001121 | ||
| 9 | 2 | Supply and erection of suitable oil immersed star delta starter/ATS/star rotor starter of standarad make such as MEI/Kilburn/Jyoti/ Siemens conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slipriing motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling . | BI01010001010000000000000515BI0100001122 | 2 | each |
| 10 | 3 | Providing and fixing M S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections including installation. The drawing of panel board shall be subject to approval of Engineer in charge. | BI01010001010000000000000515BI0100001123 | 2 | each |
| 11 | 3.01 | a) Ammeter AC supply,100 mm circular dial Auto electric/AE/IMP/Havells make of suitable range for above motor with selector switches conforming to BIS 1248-1983 latest with up to date ammendments. | BI01010001010000000000000515BI0100001124 | 2 | each |
| 12 | 3.02 | b) Voltmeter AC supply,100 mm circular dial Auto electric/AE/IMP/Havells make of suitable range for above motor with selector switches conforming to BIS 4064-1978 with up to date ammendments. | BI01010001010000000000000515BI0100001125 | 1 | each |
| 13 | 3.03 | c) ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB. | BI01010001010000000000000515BI0100001126 | 2 | each |
| 14 | 3.04 | d) Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments. | BI01010001010000000000000515BI0100001127 | 1 | each |
| 15 | 3.05 | e) MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release. | BI01010001010000000000000515BI0100001128 | 1 | each |
| 16 | 3.06 | f) 3 phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments. | BI01010001010000000000000515BI0100001129 | 2 | each |
| 17 | 3.07 | g) Earth leakage circuit breaker of recommended (Kilburn/L&T/MEI/GEC/Havells make) as per BIS-2516-1977 with upto date ammendments and of suitaible range with which should have control box, operating handle and trip/reset bush button on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted with earth fault for tripping of breaker on occurance of earth fault on/ off breaker load side. | BI01010001010000000000000515BI0100001130 | 1 | each |
| 18 | 3.08 | h) Hour run meter of reputed make of four digit capacity conforming to BIS-722(latest edition) recommendations. | BI01010001010000000000000515BI0100001131 | 2 | each |
| 19 | 3.09 | i) Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing, no voltage, high voltage & overloading & phase voltage difference. | BI01010001010000000000000515BI0100001132 | 1 | each |
| 20 | 3.1 | j) Single phase preventor of reputed make & suitable capacity | BI01010001010000000000000515BI0100001133 | 1 | each |
| 21 | 4 | k) Supply and erection of Kirloskar/ Kilburn/IVC/ Fouress/ Gled/ BHEL/ Leader/ Pelican of approved make Cast iron double flanged sluice valve 65 mm dia class PN1.0 and capable of withstanding nominal seat pressure as per BIS. | BI01010001010000000000000515BI0100001134 | 2 | each |
| 22 | 5 | Supply & erection of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEEL/Leader/Pelican make Cast iron double flanged swing check type reflux valve 65mm dia conf. to IS:5312 and capable of withstanding nominal seat pressure as per BIS. | BI01010001010000000000000515BI0100001135 | 2 | each |
| 23 | 6 | Supply & erection of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEEL/Leader/Pelican Cast iron double flanged swing check type reflux valve 100mm dia conforming to IS:5312 for withstanding nominal seat pressure as per BIS. | BI01010001010000000000000515BI0100001136 | 1 | each |
| 24 | 7 | Providing and Laying copper PVC insulated armoured power 3.1/2 core cable confirming to BIS 1554 (Part I) -1988 or latest with up to date ammendments Siemen/Gloster/ICC/L&T/Havells/Finolex/Standard make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor .The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. SIZE - 1x 3.5/4 x 2.5 sq.mm | BI01010001010000000000000515BI0100001137 | 50 | Rmtr. |
| 25 | 8 | Providing and Laying PVC jointless flat water proof cable as per BIS 694-1990 L&T/Havells/Finolex/Standard (latest with up to date ammendments) suitable for the pump sets offered from OCB to motor, motor to starter including all other electrical equipments such as Thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. SIZE- 1x3x2.5 sq.mm | BI01010001010000000000000515BI0100001138 | 30 | Rmtr. |
| 26 | 9 | Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager/Bajaj/L&T/Havells make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of 2 KVAR according to HP of motor offered including cable Siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer. | BI01010001010000000000000515BI0100001139 | 2 | each |
| 27 | 10 | Supply and erection of standarad make 100 mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments. | BI01010001010000000000000515BI0100001140 | 2 | each |
| 28 | 11 | Providing and Laying Delivery pipe considering site requirements,NPSH required & available having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 , nuts & bolts as per 1364-1983 & special from pump set to ground level i/c common header and up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1e(ii). NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge. | BI01010001010000000000000515BI0100001141 | 1 | job |
| 29 | 12 | IST STAGE\nInstallation horizontal spindle,horizontal/ radial split casing/multi stage centrifugal pump of KSB make model WL 65/12 read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze impellers /casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS base plate (base plate to be from the manufacturer of the pumping unit only) to squirrel cage screen protected drip proof induction motor /motors of standard make such as CG/Marathon motor of 75KW/100HP and suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty poiint head. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements:\n | BI01010001010000000000000515BI0100001142 | 2 | set |
| 30 | 12.01 | Discharge (Q) 7.92 LPS for each pump. | BI01010001010000000000000515BI0100001143 | ||
| 31 | 12.02 | Total Dynamic head:- 418 Mtrs | BI01010001010000000000000515BI0100001144 | ||
| 32 | 12.03 | a) LWL in sump well (h) 998.00 metre | BI01010001010000000000000515BI0100001145 | ||
| 33 | 12.04 | b) Shaft level 997.00 metre | BI01010001010000000000000515BI0100001146 | ||
| 34 | 12.05 | c) Level at discharge point 1398.25 metre | BI01010001010000000000000515BI0100001147 | ||
| 35 | 12.06 | d) Suction lift +ve metre. | BI01010001010000000000000515BI0100001148 | ||
| 36 | 12.07 | e) Discharge head 417.63 metre | BI01010001010000000000000515BI0100001149 | ||
| 37 | 12.08 | f) Static head 401.25 metre | BI01010001010000000000000515BI0100001150 | ||
| 38 | 12.09 | Rising main | BI01010001010000000000000515BI0100001151 | ||
| 39 | 12.1 | a) Length 660 mtr | BI01010001010000000000000515BI0100001152 | ||
| 40 | 12.11 | b) Dia 100 mm | BI01010001010000000000000515BI0100001153 | ||
| 41 | 12.12 | Pumping hours 8 Hours | BI01010001010000000000000515BI0100001154 | ||
| 42 | 12.13 | Altitude of installation above MSL= 1020 metre | BI01010001010000000000000515BI0100001155 | ||
| 43 | 12.14 | Characterstics of water Clear cold water with turbidity up to 50 PPM. | BI01010001010000000000000515BI0100001156 | ||
| 44 | 12.15 | a) Temperature 20 degree C. | BI01010001010000000000000515BI0100001157 | ||
| 45 | 12.16 | (Note: One pump set to act as stand by) | BI01010001010000000000000515BI0100001158 | ||
| 46 | 13 | Providing changeover switch Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 250A as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. | BI01010001010000000000000515BI0100001159 | 1 | Set |
| 47 | 14 | Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No. 12 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n | BI01010001010000000000000515BI0100001160 | 2 | Nos. |
| 48 | 14.01 | OCB/MCCB of MEI/Havels/ standard/ABB/L&T make and of 250 Ampere rating offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n | BI01010001010000000000000515BI0100001161 | 2 | Nos. |
| 49 | 14.02 | Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC/Standard/Minilac) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n | BI01010001010000000000000515BI0100001162 | 2 | Nos. |
| 50 | 14.03 | The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482 (latest edition)\n | BI01010001010000000000000515BI0100001163 | 2 | No. |
| 51 | 14.04 | Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n | BI01010001010000000000000515BI0100001164 | 1 | No. |
| 52 | 14.05 | Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto date ammendments\n | BI01010001010000000000000515BI0100001165 | 1 | No. |
| 53 | 14.06 | Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with upto date ammendments\n | BI01010001010000000000000515BI0100001166 | 1 | No. |
| 54 | 14.07 | Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n | BI01010001010000000000000515BI0100001167 | 2 | set |
| 55 | 14.08 | ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of 250 Ampere capacity as per IS:4064:1978 with upto date ammendments\n | BI01010001010000000000000515BI0100001168 | 2 | set |
| 56 | 14.09 | Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n | BI01010001010000000000000515BI0100001169 | 2 | set |
| 57 | 14.1 | Digital 100mm dia circular dial A.C.supply flush VAF of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n | BI01010001010000000000000515BI0100001170 | 2 | set |
| 58 | 14.11 | Capacitor of Mechneil/ BHEL/GEC/L&T/Havells make as per 15:2834:1986 with upto date ammendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/Gloster/ IEC make ) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n | BI01010001010000000000000515BI0100001171 | 2 | Nos. |
| 59 | 14.12 | Installation assembling oil immersed/auto transformer starter of MEI/.Kilburn/Jyoti /L&T/Siemens/SEI make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n | BI01010001010000000000000515BI0100001172 | 2 | Nos. |
| 60 | 14.13 | Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n | BI01010001010000000000000515BI0100001173 | 2 | Nos. |
| 61 | 14.14 | Providing antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971.\n | BI01010001010000000000000515BI0100001174 | 2 | Nos. |
| 62 | 15 | Providing double flanged CI sluice valve PN1 of Leader/BHEL/Kirlosker/GLEd/Kilburn Fourses / PELICAN make and 100 mm dia for suction pipe, capable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments\n | BI01010001010000000000000515BI0100001175 | 2 | Nos. |
| 63 | 16 | Providng double flanged cast steel sluice valves ASA-300 of leader/BHEL Kirlosker/Kilburn GLED/ fourses/ PELICAN make and of 80mm dia for delivery line of pump and capable of withstanding the normal seat pressure and as per BIS standards with upto date ammdnements\n | BI01010001010000000000000515BI0100001176 | 2 | Nos. |
| 64 | 17 | Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLED/Fourses/ PELICAN make of 80 mm dia for delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n | BI01010001010000000000000515BI0100001177 | 2 | Nos. |
| 65 | 18 | Providing double flanged cast steel reflux valves class ASA-300 of Leader/ BHEL/ KILROSKER/ KILBURN /GLED/ FOURSES/ PELICAN make and of 100 mm dia for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments.\n | BI01010001010000000000000515BI0100001178 | 1 | No. |
| 66 | 19 | Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n | BI01010001010000000000000515BI0100001179 | 2 | No. |
| 67 | 20 | Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n | BI01010001010000000000000515BI0100001180 | 1 | No. |
| 68 | 21 | Installation of all the items apparing at serial No. 12 to 20 as per the systematic drawing \n | BI01010001010000000000000515BI0100001181 | 1 | Job |
| 69 | 22 | Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12 The size of the various components to be as under:\n | BI01010001010000000000000515BI0100001182 | ||
| 70 | 22.01 | Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe 100 mm dia\n | BI01010001010000000000000515BI0100001183 | 10 | Rmtr |
| 71 | 22.02 | Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe 80mm dia \n | BI01010001010000000000000515BI0100001184 | 10 | Rmtr |
| 72 | 22.03 | Common header : One dia higher then delivery of pump x 100 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n | BI01010001010000000000000515BI0100001185 | 5 | Rmtr |
| 73 | 23 | Providing and laying copper PVC insulated armoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER / IEC/ ICC/ EICO/ NATIONAL/ GRANDLAY/ Havells/ L&T/Finolex/ Standard make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.\n | BI01010001010000000000000515BI0100001186 | ||
| 74 | 23.01 | (a) Motor side (From switch to starter and starter to motor) 3 CORE 50 SQMM | BI01010001010000000000000515BI0100001187 | 20 | Rmtr. |
| 75 | 23.02 | (b) Supply side (From Meter of HPSEB to bus bar and switch) 3.5 CORE 70 SQMM | BI01010001010000000000000515BI0100001188 | 20 | Rmtr. |
| 76 | 24 | Providing and fixing double loop earth with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips/wire as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect i/c earthing of raw water stage &phase-I | BI01010001010000000000000515BI0100001189 | 1 | Job |
| 77 | 25 | 2nd STAGE\nInstallation of horizontal spindle,horizontal/redial split casing/multistage centrifugal pump of KSB make model HDA 65/15 with CI + Cast steel casing ,Chrome steel impellers , chrome plated SS Shaft ( other material as per KSB standard practice for such high head pump ) as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to 180KW/ 240 HP squirrel cage screen protected drip proof induction motor /motors of standard make such as Crompton (CG) / Marathon /Kirloskar make having 2900(N) RPM and suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty poiint head. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements:\n | BI01010001010000000000000515BI0100001190 | 2 | set |
| 78 | 25.01 | Discharge (Q) 7.92 LPS for each pump. | BI01010001010000000000000515BI0100001191 | ||
| 79 | 25.02 | Total Dynamic head:- 990 Mtrs | BI01010001010000000000000515BI0100001192 | ||
| 80 | 25.03 | a) LWL in sump well (h) 1397 metre | BI01010001010000000000000515BI0100001193 | ||
| 81 | 25.04 | b) Shaft level 1396 metre | BI01010001010000000000000515BI0100001194 | ||
| 82 | 25.05 | c) Level at discharge point 2341.96 metre | BI01010001010000000000000515BI0100001195 | ||
| 83 | 25.06 | d) Suction lift +ve metre. | BI01010001010000000000000515BI0100001196 | ||
| 84 | 25.07 | e) Discharge head 989.55 metre | BI01010001010000000000000515BI0100001197 | ||
| 85 | 25.08 | f) Static head 945.96 metre | BI01010001010000000000000515BI0100001198 | ||
| 86 | 25.09 | Rising main | BI01010001010000000000000515BI0100001199 | ||
| 87 | 25.1 | a) Length 1960 mtr | BI01010001010000000000000515BI0100001200 | ||
| 88 | 25.11 | b) Dia 100 mm | BI01010001010000000000000515BI0100001201 | ||
| 89 | 25.12 | Pumping hours 8 Hours | BI01010001010000000000000515BI0100001202 | ||
| 90 | 25.13 | Altitude of installation above MSL= 1400 metre | BI01010001010000000000000515BI0100001203 | ||
| 91 | 25.14 | Characterstics of water Clear cold water with turbidity up to 50 PPM. | BI01010001010000000000000515BI0100001204 | ||
| 92 | 25.15 | a) Temperature 20 degree centigrade. | BI01010001010000000000000515BI0100001205 | ||
| 93 | 25.16 | (Note: one pump set working and one set to act as stand by to lift the total discharge of 7.92 LPS | BI01010001010000000000000515BI0100001206 | ||
| 94 | 26 | Providing Changeover switch of Kilburn/ L&T/Siemens/Standard/ Havells make and of 630 Ampere capacity as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. | BI01010001010000000000000515BI0100001207 | 1 | Set |
| 95 | 27 | Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No. 68 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n | BI01010001010000000000000515BI0100001208 | 2 | Nos. |
| 96 | 27.01 | a) OCB/MCCB of MEI/Havels/ standard/ABB/L&T make and of 500/630 Ampere for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments 500/ 630 A\n | BI01010001010000000000000515BI0100001209 | 2 | Nos. |
| 97 | 27.02 | b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC/Standard/Minilac) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n | BI01010001010000000000000515BI0100001210 | 2 | Nos. |
| 98 | 27.03 | c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482 (latest edition)\n | BI01010001010000000000000515BI0100001211 | 2 | No. |
| 99 | 27.04 | d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n | BI01010001010000000000000515BI0100001212 | 1 | No. |
| 100 | 27.05 | e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto date ammendments\n | BI01010001010000000000000515BI0100001213 | 1 | No. |
| 101 | 27.06 | f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with upto date ammendments\n | BI01010001010000000000000515BI0100001214 | 1 | No. |
| 102 | 27.07 | g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n | BI01010001010000000000000515BI0100001215 | 2 | set |
| 103 | 27.08 | h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of 630Ampere as per IS:4064:1978 with upto date ammendments\n | BI01010001010000000000000515BI0100001216 | 2 | set |
| 104 | 27.09 | i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n | BI01010001010000000000000515BI0100001217 | 2 | set |
| 105 | 27.1 | j) Digital 100mm dia circular dial A.C.supply VAF meter of AE/IMP/Havells/L&T make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n | BI01010001010000000000000515BI0100001218 | 2 | set |
| 106 | 27.11 | k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/Gloster/ IEC make ) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n | BI01010001010000000000000515BI0100001219 | 2 | Nos. |
| 107 | 27.12 | l) Providing suitable soft starter of MEI/.Kilburn/Jyoti /L&T/Siemens/AB/ABB make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n | BI01010001010000000000000515BI0100001220 | 2 | Nos. |
| 108 | 27.13 | m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n | BI01010001010000000000000515BI0100001221 | 2 | Nos. |
| 109 | 27.14 | n) Providing antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971.\n | BI01010001010000000000000515BI0100001222 | 2 | Nos. |
| 110 | 28 | Providing double flanged CI sluice valve PN1 of Leader/BHEL/Kirlosker/GLEd/Kilburn Fourses / Pelican make and of 100 mm dia for suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments\n | BI01010001010000000000000515BI0100001223 | 2 | Nos. |
| 111 | 29 | Providng double flanged cast steel sluice valves ASA-600 of leader/BHEL Kirlosker/Kilburn GLED/ Fourses/Pelican make 80mm dia capable of withstanding the normal seat pressure and as per BIS standards with upto date ammdnements\n | BI01010001010000000000000515BI0100001224 | 2 | Nos. |
| 112 | 30 | Providing double flanged swing type cast steel valve, ASA-600 of Leader/BHEL/ Kirlosker/Kilburn /GLED/Fourses/Pelican make 80 mm dia and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n | BI01010001010000000000000515BI0100001225 | 2 | Nos. |
| 113 | 31 | Providing double flanged cast steel reflux valves class ASA-600 of Leader/ BHEL/ KILROSKER/ KILBURN /GLED/ FOURSES/Pelican make and of 100 mm dia for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments.\n | BI01010001010000000000000515BI0100001226 | 1 | No. |
| 114 | 32 | Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n | BI01010001010000000000000515BI0100001227 | 2 | No. |
| 115 | 32.01 | Supply and erection of automatic power factor correction Panel of reputed make confirming to relevant IS specifications with up to date amendments\" | BI01010001010000000000000515BI0100001228 | 1 | Job |
| 116 | 33 | Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n | BI01010001010000000000000515BI0100001229 | 1 | No. |
| 117 | 34 | Installation of all the items apparing at serial No. 25 to 33 as per the systematic drawing \n | BI01010001010000000000000515BI0100001230 | 1 | Job |
| 118 | 35 | Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.55. The size of the various components to be as under:\n | BI01010001010000000000000515BI0100001231 | ||
| 119 | 35.01 | Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe 100mm dia\n | BI01010001010000000000000515BI0100001232 | 10 | Rmtr |
| 120 | 35.02 | Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe 80 mm dia\n | BI01010001010000000000000515BI0100001233 | 10 | Rmtr |
| 121 | 35.03 | Common header : One dia higher then delivery of pump x 100 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n | BI01010001010000000000000515BI0100001234 | 5 | Rmtr |
| 122 | 36 | Providing and laying copper PVC insulated armoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC /ICC /EICO /NATIONAL /GRANDLAY /L&T /Havells /Finolex /Standard make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.\n | BI01010001010000000000000515BI0100001235 | ||
| 123 | 36.01 | (a) Motor side (From switch to starter and starter to motor) 3 CORE 120 SQMM | BI01010001010000000000000515BI0100001236 | 20 | Rmtr. |
| 124 | 36.02 | (b) Supply side (From Meter of HPSEB to bus bar and switch) 3.5 CORE 120 SQMM | BI01010001010000000000000515BI0100001237 | 20 | Rmtr. |
| 125 | 37 | Providing and fixing double loop earth with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect . | BI01010001010000000000000515BI0100001238 | 1 | Job |
| 126 | 38 | 3rd STAGE\nInstallation of horizontal spindle,horizontal/redial split casing/end suction(Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty poiint head. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements:\n | BI01010001010000000000000515BI0100001239 | 2 | set |
| 127 | 38.01 | Discharge (Q) 28.50 m^3/Hr for each pump. | BI01010001010000000000000515BI0100001240 | ||
| 128 | 38.02 | Total Dynamic head:- 355.3 Mtrs | BI01010001010000000000000515BI0100001241 | ||
| 129 | 38.03 | a) LWL in sump well (h) 2339.46 metre | BI01010001010000000000000515BI0100001242 | ||
| 130 | 38.04 | b) Shaft level 2338.96 metre | BI01010001010000000000000515BI0100001243 | ||
| 131 | 38.05 | c) Level at discharge point 2666 metre | BI01010001010000000000000515BI0100001244 | ||
| 132 | 38.06 | d) Suction lift +ve metre. | BI01010001010000000000000515BI0100001245 | ||
| 133 | 38.07 | e) Discharge head 327.04 metre | BI01010001010000000000000515BI0100001246 | ||
| 134 | 38.08 | f) Static head 327.04 metre | BI01010001010000000000000515BI0100001247 | ||
| 135 | 38.09 | Rising main | BI01010001010000000000000515BI0100001248 | ||
| 136 | 38.1 | a) Length 1980 mtr | BI01010001010000000000000515BI0100001249 | ||
| 137 | 38.11 | b) Dia 100 mm | BI01010001010000000000000515BI0100001250 | ||
| 138 | 38.12 | Pumping hours 8 Hours | BI01010001010000000000000515BI0100001251 | ||
| 139 | 38.13 | Altitude of installation above MSL= 1750 metre | BI01010001010000000000000515BI0100001252 | ||
| 140 | 38.14 | Characterstics of water Clear cold water with turbidity up to 50 PPM. | BI01010001010000000000000515BI0100001253 | ||
| 141 | 38.15 | a) Temperature 20 degree centigrade. | BI01010001010000000000000515BI0100001254 | ||
| 142 | 38.16 | (Note: One pump set to act as stand by) | BI01010001010000000000000515BI0100001255 | ||
| 143 | 39 | Providing Changeover switchof Kilburn/ L&T/ Siemens/ Standard/ Havells make and having capacity 160 Ampere of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. | BI01010001010000000000000515BI0100001256 | 1 | Set |
| 144 | 40 | Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No. 81 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n | BI01010001010000000000000515BI0100001257 | 2 | Nos. |
| 145 | 40.01 | a) OCB/MCCB of MEI/Havels/ standard/AABB/L&T make and of 160A capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n | BI01010001010000000000000515BI0100001258 | 2 | Nos. |
| 146 | 40.02 | b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC/ Standard/ Minilac ) as per IS:2516 :1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n | BI01010001010000000000000515BI0100001259 | 2 | Nos. |
| 147 | 40.03 | c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482 (latest edition)\n | BI01010001010000000000000515BI0100001260 | 2 | No. |
| 148 | 40.04 | d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n | BI01010001010000000000000515BI0100001261 | 1 | No. |
| 149 | 40.05 | e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto date ammendments\n | BI01010001010000000000000515BI0100001262 | 1 | No. |
| 150 | 40.06 | f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with upto date ammendments\n | BI01010001010000000000000515BI0100001263 | 1 | No. |
| 151 | 40.07 | g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n | BI01010001010000000000000515BI0100001264 | 2 | set |
| 152 | 40.08 | h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of 160 Ampere capacity as per IS:4064:1978 with upto date ammendments\n | BI01010001010000000000000515BI0100001265 | 2 | set |
| 153 | 40.09 | i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n | BI01010001010000000000000515BI0100001266 | 2 | set |
| 154 | 40.1 | j) Digital 100mm dia circular dial A.C.supply flush VAF meter of AE/IMP/Havells/L&T make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n | BI01010001010000000000000515BI0100001267 | 2 | set |
| 155 | 40.11 | k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of 15 KVAr rting according to H.P.offered including cables as per relevant ISI code (of siemens/Gloster/ IEC make ) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n | BI01010001010000000000000515BI0100001268 | 2 | Nos. |
| 156 | 40.12 | l) Providing suitable oil immersed /auto transformer starter of MEI/.Kilburn/Jyoti /L&T/Siemens/ABB make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n | BI01010001010000000000000515BI0100001269 | 2 | Nos. |
| 157 | 40.13 | m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n | BI01010001010000000000000515BI0100001270 | 2 | Nos. |
| 158 | 40.14 | n) Providing antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971.\n | BI01010001010000000000000515BI0100001271 | 2 | Nos. |
| 159 | 41 | Providing double flanged CI sluice valve PN1 of Leader/BHEL/Kirlosker/GLEd/Kilburn Fourses / Pelican make and of 80mm dia for suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments\n | BI01010001010000000000000515BI0100001272 | 2 | Nos. |
| 160 | 42 | Providng double flanged cast steel sluice valves ASA-300 of leader/BHEL Kirlosker/Kilburn GLED/ fourses /Pelican make of 65mm dia and capable of withstanding the normal seat pressure and as per BIS standards with upto date ammdnements\n | BI01010001010000000000000515BI0100001273 | 2 | Nos. |
| 161 | 43 | Providing double flanged swing check type reflux cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/ Fourses/ Pelican make of 65mm dia and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n | BI01010001010000000000000515BI0100001274 | 2 | Nos. |
| 162 | 44 | Providing double flanged cast steel reflux valves class ASA-300 of Leader/ BHEL/ KILROSKER/ KILBURN /GLED/ FOURSES/Pelican make and of 100 mm dia for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments.\n | BI01010001010000000000000515BI0100001275 | 1 | No. |
| 163 | 45 | Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n | BI01010001010000000000000515BI0100001276 | 2 | No. |
| 164 | 46 | Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n | BI01010001010000000000000515BI0100001277 | 1 | No. |
| 165 | 47 | Installation of all the items apparing at serial No. 38 to 46 as per the systematic drawing \n | BI01010001010000000000000515BI0100001278 | 1 | Job |
| 166 | 48 | Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.81. The size of the various components to be as under:\n | BI01010001010000000000000515BI0100001279 | ||
| 167 | 48.01 | Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe 80mm dia\n | BI01010001010000000000000515BI0100001280 | 10 | Rmtr |
| 168 | 48.02 | Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe 65 mm dia\n | BI01010001010000000000000515BI0100001281 | 10 | Rmtr |
| 169 | 48.03 | Common header : One dia higher then delivery of pump x 100 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n | BI01010001010000000000000515BI0100001282 | 5 | Rmtr |
| 170 | 49 | Providing and laying copper PVC insulated armoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC /ICC/ EICO/ NATIONAL/ GRANDLAY/ Havells/L&T/ Finolex/ Standard make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.\n | BI01010001010000000000000515BI0100001283 | ||
| 171 | 49.01 | (a) Motor side (From switch to starter and starter to motor) 3 CORE 25 SQMM | BI01010001010000000000000515BI0100001284 | 20 | Rmtr. |
| 172 | 49.02 | (b) Supply side (From Meter of HPSEB to bus bar and switch) 3.5 CORE 25 SQMM | BI01010001010000000000000515BI0100001285 | 20 | Rmtr. |
| 173 | 50 | Providing and fixing double loop earth with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips/wire as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect . | BI01010001010000000000000515BI0100001286 | 1 | Job |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy