Provision Of 01 Xsoakage Well And Septic Tank Near Bldg No T-10 , Accn Of Ni Picket With Att Bathroom And Toilet And Special Repair/Replacement Of Lightning Protection System And Earthing Of Various E/M Instlns Incl Certain B/R Rev/Minor Wks At Dinjan M, DINJAN MIL STN-Assam

Military Engineer Services-MES has published Provision Of 01 Xsoakage Well And Septic Tank Near Bldg No T-10 , Accn Of Ni Picket With Att Bathroom And Toilet And Special Repair/Replacement Of Lightning Protection System And Earthing Of Various E/M Instlns Incl Certain B/R Rev/Minor Wks At Dinjan M. Submission Date for this Tender is 19-12-2020. Electrification Work Tenders in DINJAN MIL STN Assam. Bidders can get complete Tender details and download the document.




Tender Notice

26118896
Corrigendum : Provision Of 01 Xsoakage Well And Septic Tank Near Bldg No T-10 , Accn Of Ni Picket With Att Bathroom And Toilet And Special Repair/Replacement Of Lightning Protection System And Earthing Of Various E/M Instlns Incl Certain B/R Rev/Minor Wks At Dinjan M
Open Tender
Indian
Assam
DINJAN MIL STN
19-12-2020

Tender Details

Provision Of 01 Xsoakage Well And Septic Tank Near Bldg No T-10 , Accn Of Ni Picket With Att Bathroom And Toilet And Special Repair / Replacement Of Lightning Protection System And Earthing Of Various E / M Instlns Incl Certain B / R Rev / Minor Wks At Dinjan Mil Stn

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Dec-2020 REVISED BOQ BOQ 12-12-2020
2 12-Dec-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-12-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 82200.0 /-
Tender Value
INR 41.10 Lakhs /-

BOQ Items

Name of Work: PROVN OF 01xSOAKAGE WELL AND SEPTIC TANK NEAR BLDG NO T-10, ACCN OF NI PICKET WITH ATT BATHROOM AND TOILET AND SPL REPAIR/REPLACEMENT OF LIGHTNING PROTECTION SYSTEM AND EARTHING OF VARIOUS E/M INSTALLATIONS INCLUDING CERTAIN B/R REVENUE/MINOR WORKS AT DINJAN MIL STN
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Surface dressing not exceeding 15 cm deep and getting out in soft/loose soil complete all as specified and as directed. 200 Sqm
2 2 Surface excavation not exceeding 30cm deep and averaging 15cm deep and and getting out including in soft/loose soil complete all as specified and as directed. 421 Sqm
3 3 Excavation over areas not exceeding 1.5 m in depth and getting out in soft/loose soil complete as specified and as directed. 36 Cum
4 4 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed. 175 Cum
5 5 Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed. 19 Cum
6 6 Excavation in trenches not exceeding 1.5 m wide and exceeding 3.0 m but not exceeding 4.50 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed. 11 Cum
7 7 Returning, filling in, including spreading in layers not exceeding 25cm levelling, watering and well ramming in soft/loose soil complete all as specified and as directed. 127 Cum
8 8 Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. 177 Cum
9 9 Excavating in post holes (or similar holes) each not exceeding 0.5 Cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm watering and removing surplus soil to a distance n.exc 50m and making good surface in soft/loose soil complete all as specified and as directed. 10 Each
10 10 M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed. 15 Sqm
11 11 M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed. 40 Sqm
12 12 M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.\n 25 Sqm
13 13 M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, filling, sub base of floors and mass concrete, etc complete all as specified and as directed. 14.1 Cum
14 14 M&L for brick work using locally available first class bricks sub class 'B' bricks (old size brick), straight or curved on plan exceeding 6 m mean radius, built in cement mortar 1:6 complete all as specified and as directed. 56 Cum
15 15 M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius, built in cement mortar (1:4) as in half brick thick walls complete all as specified and as directed. 15 Sqm
16 16 M&L for 25mm thick Damp proof course in cement concrete (1:2:4), type B-0 (using 12.50mm stone aggregate) to horizontal or vertical surfaces including necessary form work complete all as specified and as directed. 10 Sqm
17 17 M&L for brick work using locally available first class bricks sub class 'B' bricks (old size brick), in one brick thick Honey comb walling, built in cement mortar (1:6) complete all as specified and as directed. 22 Sqm
18 18 M&L for plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in lintel upto 1.5m span, cills and other similar band, plinth course, parapet, railing upto 60cm height, coping, kneelers, bed plates etc including weathering slightly rounded or chamfered angles including necessary form work complete all as specified and as directed. 1.5 Cum
19 19 M&L for salt glazed stone ware drain pipes 150 mm bore, grade 'A' laid in trenches, jointed and tested complete all as specified and as directed. 60 RM
20 20 M&L for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggragate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore SGSW/RCC drain pipes complete all as specified and as directed . 60 RM
21 21 M&L for precast reinforced cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in cover slab of manholes, septic tank and the like, set in cement mortar (1:4) complete all as directed. \nNote : Reinforcement steel shall be measured and paid separately. 4.4 RM
22 22 S&F TMT steel bars 10 mm dia and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and as directed. 905 Kg
23 23 M&L for TMT steel bars 6 to 8mm dia, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. 260 Kg
24 24 S&F TMT steel bars 6mm dia., and over cut to length, bend to shape required, including cranking, bending spirally as in, stirrups, nibs, spacers and binders binding with and including providing mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 280 Kg
25 25 Extra for forming fair finished to concrete surface of drain 30cm inner girth in cement including forms, mould, mitred/stopped etc complete all as specified and as directed.\n 12 RM
26 26 M&L for use and waste form work to sides of foundation, footings, bases of columns, plinth beams flat rough finished surfaces of concrete complete all as specified and as directed. \n 50.5 Sqm
27 27 M&L for use and waste form work to sides of pillar, columns, etc. flat rough finished surfaces of concrete complete all as specified and as directed. \n 78.5 Sqm
28 28 M&L for use and waste form work to soffits and sides of lintel beam, roof beam, cantilevers, shelvers, for flat rough finished surfaces of concrete complete all as specified and as directed. 67 Sqm
29 29 M&L for use and waste form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and as directed. 66 Sqm
30 30 M&L for use and waste form work to partition wall and similar work, flat rough finished surfaces of concrete complete all as specified and as directed. 15 Sqm
31 31 M&L for use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n.exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide complete all as specified and as directed.\n 15 RM
32 32 M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in foundation including footing, plinth beams, bases of column etc complete all as specified and as directed.\n 10.2 Cum
33 33 M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in beam, lintel, cantilevers etc complete all as specified and as directed.\n 5.4 Cum
34 34 M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in columns, pillars, post and struts etc complete all as specified and as directed. 5.25 Cum
35 35 M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in slabs supported on wall, roof beams etc complete all as specified and as directed.\n 6.25 Cum
36 36 M&L for loose filling of broken brick with aggregates of gauge 80 to 150 mm in soakage pits, soakage wells complete all as specified and as directed. 15 Cum
37 37 M&L for 150mm bore cast iron, sand cast soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and as directed. 17 RM
38 38 M&L for 75mm bore cast iron, sand cast soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and as directed. 13 RM
39 39 S&F for 75mm bore slotted Vent cowl complete all as specified and as directed. 7 Each
40 40 M&L for hardcore of gauge not exceeding 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. 55 Cum
41 41 M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as as directed. 8 Cum
42 42 M&L for 100 mm thick plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub-base of flooring, etc complete all as specified and as directed. 421 Sqm
43 43 M&L for 75 mm thick plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in footpath, plinth protection, hardstanding, etc. finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed. 313 Sqm
44 44 Forming construction joints 30mm deep x 10mm wide, filled with sealing compound Grade 'A' complete all as specified and as directed. 19 Per 10 RM
45 45 M&L for 40 mm thick, plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in floors and finishing the surfaces even and smooth with using extra cement complete all as specified and as directed. 15 Sqm
46 46 Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed 50 Sqm
47 47 M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) mixed with integral water proofing compound weight of cement as per manufacturer's instructions and finished surface even and smooth without using extra cement complete all as specified and as directed. \nNote : WPC shall be measured and paid separately. 175 Sqm
48 48 Supply only integral water proofing compound (ISI marked) complete all as specified and as directed. 8 Kg
49 49 M&L for rendering 20 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:3) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. 60 Sqm
50 50 M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick masonry or concrete surfaces and finishing surfaces even and fair without using extra cement complete all as specified and as directed.\n 160 Sqm
51 51 M&L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick masonry or concrete surfaces and finishing surfaces even and fair without using extra cement complete all as specified and as directed.\n 115 Sqm
52 52 M&L for rendering 5 mm thick in cement mortor (1:3) on concrete surfaces as in ceilings (sunshed, chajja etc) and finishing surfaces even and smooth without using extra cement complete all as specified and as directed. 25 Sqm
53 53 M&L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed. 75 Sqm
54 54 M&L for preparation new external surfaces of wall, chajja, facia etc and applying two coats of water based acrylic weather proof exterior emulsion (exterior wall finish) paint over a coat of primer as per manufacturer's instruction complete all as specified and as directed. 100 Sqm
55 55 M&L for preparing new surfaces of ceiling and applying three coats of white wash complete all as specified and directed. 60 Sqm
56 56 M&L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.\n 35 Sqm
57 57 S&F for 500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) multi layered type, hoisted and fixed in position as specified in SSR Part I complete all as specified and as directed. 1 Each
58 58 S&F for 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), multi layered type, hoisted and fixed in position as specified in SSR Part I complete all as specified and as directed. 1 Each
59 59 S&F for 20 mm bore, ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and as directed. 2 Each
60 60 S&F for 20 mm dia gate valve cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and as directed. 1 Each
61 61 S&F for 15 mm bore, bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. 5 Each
62 62 S&F for towel rail, 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and as directed. 1 Each
63 63 S&F for soap dish, vitreous china white, approximate size 160mm x 160mm x 90mm, embedded in walls/fixed to plugs with chromium plated brass screws complete all as specified and as directed. 1 Each
64 64 S&F for 100mm bore stack clamps out of 50x5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and as directed. 4 Each
65 65 S&F for 15 mm bore, angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm-90gms) complete all as specified and as directed. 2 Each
66 66 S&F for harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers, etc as in curtain rail complete all as specified and as directed. 25 RM
67 67 S&F for 300 mm long, mild steel, ordinary rat tail rod pattern springs incuding roller and roller plate complete all as specifed and as directed. 2 Each
68 68 M&L for drilling and tapping cast iron water mains (in position) for branch connections of internal dia 25/40/50mm complete all as specified and as directed. 1 Each
69 69 Supply, laying, connection and testing 20mm outer dia 3- layer PP-R (Polypropylene random co-polymer) pipes green in colour. SDR 7.4 (PN16) stablised and antimi-crobial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fittings fixture complete fix to walls ceiling or in floors with necessary fixing arrangment clamp,screw complete all as directed. 10 RM
70 70 Supply, laying, connection and testing 25mm outer dia 3- layer PP-R (Polypropylene random co-polymer) pipes green in colour. SDR 7.4 (PN16) stablised and antimi-crobial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fittings fixture complete fix to walls Ceiling or in floors with necessary fixing arrangment clamp,screw complete all as directed. 10 RM
71 71 Supply, laying, connection and testing 32mm outer dia 3- layer PP-R (Polypropylene random co-polymer) pipes green in colour. SDR 7.4 (PN16) stablised and antimi-crobial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fittings fixture complete fix to walls Ceiling or in floors with necessary fixing arrangment clamp,screw complete all as directed. 12 RM
72 72 Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exc 10 cm but n.exc 20 cm girth complete all as specified and as directed. 19 RM
73 73 S&F in repairs, vitreous china squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rest and 'P' or 'S' trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor to match with existing specifications complete all as specified and as directed. 1 Each
74 74 S&F for vitreous china squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rest and 'P' or 'S' trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor to match with existing specifications complete all as specified and as directed. 1 Each
75 75 S&F in repairs, Vitreous China bowl urinal flat back, of size 465x355x265mm, white (minimum) with grating and union for discharge pipe (excluding flushing cistern, flush pipe & waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete complete as specified and as directed. 3 Each
76 76 Taking up or down 15 mm bore steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work complete all as specified and as directed. 10 RM
77 77 Taking up or down 20 mm bore steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work complete all as specified and as directed. 10 RM
78 78 S&F for 15 mm bore, steel tubes, galvanised, medium grade with all fittings and fixed complete to wall and ceiling or laid in floors etc complete all as specified and as directed. 25 RM
79 79 S&F for 20 mm bore, steel tubes, galvanised, medium grade with all fittings and fixed complete to wall and ceiling or laid in floors etc complete all as specified and as directed. 18 RM
80 80 S&F for 32 mm bore, steel tubes, galvanised, medium grade with all fittings and fixed complete to wall and ceiling or laid in floors etc complete all as specified and as directed. 5 RM
81 81 S&F for vitreous china wash basin, size 550 x 400mm, white, flat back, with PVC waste pipe, CP waste coupling, chain, plug and porcelean stopper & backets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and as directed.\nMake : Parryware, Cat No C0450 or equivelant of make as specified in list of manufacturer. 2 Each
82 82 S&F for 10 litre capacity, PVC valveless syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets and 32 mm dia. PVC connection pipe 600mm long complete all as specified and as directed. 2 Each
83 83 S&F for 15 mm bore, stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed. 6 Each
84 84 S&F for 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and as directed. 10 Each
85 85 S&F for 75 mm bore, PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed. 9 Each
86 86 S&F for 110 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and as directed. 33 RM
87 87 S&F for 110 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes in any length with or without ears, with cement joints, fixed to wall, ceilling, etc complete all as specified and as directed. 9 RM
88 88 S&F for 75 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and as directed. 13 RM
89 89 S&F for 75 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes in any length with or without ears, with cement joints, fixed ro wall or ceiling, etc complete all as specified and as directed. 24 RM
90 90 S&F for 110 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed. 11 Each
91 91 S&F for 110mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed. 8 Each
92 92 S&F for 110 mm bore, PVC (SWR) bends with oval access door of any radius complete all as specified and as directed. 6 Each
93 93 S&F for 75 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed. 12 Each
94 94 Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete (1:2:4) type B1, smooth finished and reforming benching as required for 110 mm bore of pipe complete all as specifieed and as directed. 1 Each
95 95 M&L for 150x150 mm size, salt glazed stoneware gully traps, square or round mouthed, type 'P' including all fixing arrengements complete all as specified and as directed. 2 Each
96 96 M&L for 100x100 mm size, salt glazed stoneware gully traps, square or round mouthed, type 'P' including all fixing arrengements complete all as specified and as directed. 1 Each
97 97 S&F for 600mmX450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with chromiun plated brass screws and cup washers complete all as specified and as directed. 4 Each
98 98 S&F for grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and as directed. 3 Each
99 99 S&F for 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed. 1 Each
100 100 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed. 50 Sqm
101 101 M&L for machine cut kota stone slab flooring 20 to 25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match shade of slab including rubbing, polishing and 15 mm thick, screed bed or bedding in cement mortar (1:6) complete all as specified and as directed. 5.5 Sqm
102 102 M&L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm, in floors etc. including 15 mm thick screed bed or bedding in cement mortor (1:6) and set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed. 46 Sqm
103 103 M&L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06Sqm but not exceeding 0.11Sqm, in floors etc, including 15 mm thick screed bed or bedding in cement mortor (1:6) and set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.\n 15 Sqm
104 104 M&L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06Sqm but not exceeding 0.11Sqm, as in skirting etc, including 10 mm thick backing coat in cement mortor (1:4) and set and jointed in neat cement slurry and pointed in white or coloured cement to match with shade of tiles complete all as specified and as directed. 5 Sqm
105 105 M&L for glazed, ceramic, coloured tiles 7 to 8 mm thick area of each tile not less than 0.06Sqm on vertical surfaces such as skirting, dados etc, including 10 mm thick backing coat in cement mortor (1:4) and set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.\n 70 Sqm
106 106 M&L for chequered cement concrete tiles of size 25cm x 25cm x 22mm thick, as in floors etc, including 15 mm thick screed bed or bedding in cement mortar (1:6) and set and jointed in neat cement slurry and pointed in grey cement and pigments to match with shade of tiles complete all as specified and as directed. 70 Sqm
107 107 M&L for plain cement concrete (1:2:4) type B-1, (using 20 mm graded stone aggregate) as in benching, coping, lintel upto 1.5m span cast in situ including necessary form work complete all as specified and as directed. 3.5 Cum
108 108 M&L for precast machine pressed interlocking paver block any shaped and size conforming to IS-15658-2006, 60mm thick, M-35 grade concrete with grey cement and no pigment, set and jointed in dry sand including providing 60mm thick dry sand filling below paver blocks complete all as specified and as directed. 87 Sqm
109 109 M&L for water proofing treatment on RCC roof etc. comprising with the following operation and as specified herein below and as directed :- \n(a) Taking down existing old tarfelt, bituminous compound including cleaning & removing debris to a distance exc 100m and n.exc.250m. \n(b) 15 mm thick plastering in cement mortar (1:4) finished even and smooth. \n(c) Preparing and cleaning of fully dried cement plastered surface. \n(d) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming IS-3384. \n(e) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. \n(f) One coat of aluminium paint over the APP based membrane @ 0.11 Kg/Sqm 8 Sqm
110 110 Dismantling of asbestos cement (Corrugated, Semi corrugated etc.) sheets in roof coverings with ridges complete all as specified and as directed.\n\n 142 Sqm
111 111 Dismantling timber boarding, any description, fixed in any position with nails complete all as specified and as directed. 10 Sqm
112 112 Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. 0.2 Qtl
113 113 S&F for mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as speicfied and as directed. 415 Kg
114 114 M&L for rolled mild steel as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pices, cleat etc conforming to Fe-290 (Gde E-165) complete all as specified and as directed. 805 Kg
115 115 M&L for chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 (Gde E-165) complete all as specified and as directed. 60 Kg
116 116 S&F for rolled mild steel in plates (plain or chequered) channels fo grade Fe- 290 (Gde E-165) square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as speicfied and as directed. 20 Kg
117 117 S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of profile as approved, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. 231 Sqm
118 118 S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and as directed.\nNote : Colour of ridge shall be same colour as that of sheet used for roof. 18 Sqm
119 119 S&F for aluminium anodised snap grid frame work of size 600mm x 600mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestor E-board, HSPC fixed to frame complete all as specified and as directed. 40 Sqm
120 120 S&F for 20 mm thick, second class hard wood Boarding, clean sawn, planed one side with butt joints and fixed with nails in any situation as in eaves board, etc complete all as specified and as directed. 22 Sqm
121 121 S&F for galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed.\n 15 Sqm
122 122 S&F in repair, galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed.\n 7 Sqm
123 123 Taking down chowkats or frame not exceeding 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and as directed. 18 Each
124 124 Taking down chowkats or frames exeeeding 1.5 but not exceeding 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and as directed. 6 Each
125 125 S&F for well seasoned 2nd class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed. 0.02 Cum
126 126 S&F for pressed steel frames for doors local work shop made of size 105x60mm with one or more rebates using cold rolled commercial mild steel sheet of 1.2mm thick including necessary fixing lugs, 100mm butt hinges, lock strike plate, shock absorber etc and PCC filling of hollow section using plain cement concrete (1:3:6) type C-1 complete all as specified and as directed. 23.2 RM
127 127 S&F for pressed steel frames for doors local work shop made of size 125x60mm with one or more rebates using cold rolled commercial mild steel sheet of 1.2mm thick including necessary fixing lugs, 100mm butt hinges, lock strike plate, shock absorber etc and PCC filling of hollow section using plain cement concrete (1:3:6) type C-1 complete all as specified and as directed. 15 RM
128 128 M&L for 35mm thick 2nd class hard wood Plain, framed, panelled shutters (any number of panels), with panels of 12mm thick veneered particle board medium density with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed, Sizes/section of members of shutters shall be as specified in SSR Part I, Sec -8, clause 8.24 (a). 17.1 Sqm
129 129 S&F for 35 mm thick, second class hardwood glazed and skeleton shutters open rebated and prepared to receive glass, gauge, etc, divided in to squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded complete all as specified and as directed in SSR Part I Section 8 clause 8.24 (a). 6.2 Sqm
130 130 S&F for 30 mm thick, second class hardwood glazed and skeleton shutters open rebated and prepared to receive glass, gauge, etc, divided in to squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded complete all as specified and as directed in SSR Part I Section 8 clause 8.24 (b). 1.5 Sqm
131 131 S&F for steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed. 17.4 Sqm
132 132 S&F for steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and as directed. 6 Sqm
133 133 S&F for steel ventilator with top hung shutter including hinges, steel peg stay, complete complete all as specified and as directed. 0.3 Sqm
134 134 S&F for aluminum anodized glazed ventilators with frame of standard section and grill including provision of glazing with 5 mm thick glass fixed to frame, rubber beading, handles and tower bolts etc including taking down of old steel windows complete all as specified and as directed. 0.5 Sqm
135 135 S&F for solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed. 53 RM
136 136 S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded, plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification and drawing and as directed. 16.7 Sqm
137 137 S&F for mild steel work as in band, strap, hold fast, cleat, support, hook, hinges, base tie for door frame etc and other similar items conforming to Fe-290 (Gde Fe-165) complete all as specified and as directed. 13 Kg
138 138 M&L for plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etc including necessary form work complete all as specified and as directed. 0.2 Cum
139 139 S&F for 100 mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed. 93 Each
140 140 S&F for 150 mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed. 2 Each
141 141 S&F for 125 mm size aluminium handles, cast type, anodised complete all as specified and as directed. 30 Each
142 142 S&F for 150 mm size aluminium handles, cast type, anodised complete all as specified and as directed. 20 Each
143 143 S&F for 100 mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed. 6 Each
144 144 S&F for 100 mm long mild steel, barrel tower bolts, stove enamelled black, with bright bolt complete all as specified and as directed. 4 Each
145 145 S&F for 150 mm long mild steel, barrel tower bolts, stove enamelled black, with bright bolt complete all as specified and as directed. 6 Each
146 146 S&F for aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt of 250 mm complete all as specified and as directed. 2 Each
147 147 S&F for mild steel sliding door bolts, 250 mm long, plate type, stove enamelled black, with bright bolts not less than 12mm dia with & including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, etc complete all as specified and as directed. 6 Each
148 148 S&F for 3 mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed. 19 Sqm
149 149 S&F for aluminium locking bolts, anodised, with bolt not less than 10mm dia, 100 mm size complete all as specified and as directed.\n 2 Each
150 150 S&F for floor door stopper of 140 mm overall length of cover plate, brass body and tongue with hard drawn steel spring, fixed in floor complete all as specified and as directed. 2 Each
151 151 M&L for preparation of new steel surfaces of any description over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and as directed. 64 Sqm
152 152 M&L for preparation of old painted steel surfaces of any description, not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed. 6 Sqm
153 153 M&L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. 54 Sqm
154 154 S&F in repairs, 15 mm bore bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. 6 Each
155 155 S&F in repairs, swival shower of PTMT 15mm bore (minimum weight 40 gms) including shower arm 15mm size, 195mm long with bend of 45 degree with flange of PTMT any colour (minimum wt 40 gms) complete all as specified and as directed.\n 4 Each
156 156 S&F in repairs, 15 mm bore stop valves, cast copper alloy, chromium plated with long shank and cup, concealed type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed. 4 Each
157 157 S&F for 15 mm bore, stop valves, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed. 3 Each
158 158 S&F in repairs, 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed. 3 Each
159 159 S&F in repairs, 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and as directed. 4 Each
160 160 S&F for earth continuity conductor or main earthing lead with galvanised iron wire 4mm dia, fixed to wall on batten or recesses or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all specification and as directed. 40 RM
161 161 M&L for maintenance of existing earthing by cleaning earth chamber funnel, in and around the chamber by removing the vegetation complete and adding adequate water with 20 Kg salt complete all specification and as directed. 185 Each
162 162 M&L for replacement of damaged earth chambers with construction of PCC foundation with cement concrete 1:2:4, type B-2 (using 20 mm graded stone aggregate), of size 300 x 300 x 40 mm (internal dimentsions) with necessary formwork to be embedded with MS Angle iron frame complete complete all as specified and as directed. 75 Each Job
163 163 M&L for replacement of damaged earth chamber's cover slab by Precast RCC cover 1:2:4 type B1(using 12.5mm graded stone aggregate), of size 300mm x 300mm x 30mm thick including necessary formwork and 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, top of the cover slab shall be painted in black colour with white coloured letters indicating the tested result values and dates complete all as specified and as directed. 65 Each
164 164 Dismantling old unserviceable funnel from existing earth chamber and including S&F funnel with 20mm bore GI medium grade pipe for watering at existing chamber, complete all as specified and as directed. 35 Each
165 165 S&F for 15 mm bore, GI steel tubing (light grade) fixed on walls, floors, in ground etc for GI wire protection including dismantling of the unserviceable one, complete all as specified and as directed. 65 Each
166 166 S&F for 25 mm bore, GI steel tubing (light grade) fixed on walls, floors, in ground etc for GI wire protection including dismantling of the unserviceable one, complete all as specified and as directed. 30 Each
167 167 S&F for 40 mm bore, GI steel tubing (light grade) fixed on walls, floors, in ground etc for GI wire or UG cable protection including dismantling of the unserviceable one, complete all as specified and as directed. 36 Each
168 168 M&L for making grooves in existing PCC floor for inserting pipe/strip etc. and making good the same by matching with existing all as specified and as directed 2 Each
169 169 M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 Nos, 8 mm dia 25 mm long hexagonal head screw including dismantling of the unserviceable one complete all as specified and as directed. 95 Each
170 170 M&L for making of name board with 6mm thick PVC board (heavy duty, weather proof) and letters of size and font as desired by the deptt (sticker type computor letters), duly fixd to the wall with suitable fixing arrangements etc. complete all as specified and as directed. 10 Sqm
171 171 M&L for earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm dia by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing alongwith submission of test results complete inclduing taking down old earthing complete as specified and as directed. 92 Each Set
172 172 M&L for earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing alongwith submission of test results complete inclduing taking down old earthing as specified and as directed. 13 Each Set
173 173 S&F for air termination single pointed aluminium rod 12 mm dia 300 mm long in built with GI pipe of midium grade of 25mm dia (1.5 Mtr long) suitable nut, bolts, screws, washers complete as specified and as directed. 35 Each Set
174 174 S&F for aluminium Strip 25 x3.15 mm size with nuts, bolts and washers and perceliain insulator for roof conductors and down conductor above ground complete all as specified and as directed. 220 RM
175 175 S&F for galvanised iron strip ISI marked of size 32x6 mm complete with nuts, bolts and washers complete all as specified and as directed. 172 RM
176 176 Supply and laying well burnt bricks, sub class 'B' bricks laid width wise across the length of cable in trenches for protection of UG cables complete all as specified and as directed. 1.5 Per 1000 Nos
177 177 M&L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) including filling, spreading and punning to desired thickness complete all as specified and as directed. Note : Punned down thickness shall be considered for measurement and payment. 15 Cum
178 178 Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 10 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. \n 230 RM
179 179 M&L for concealed point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables of 1.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size passing through and including suitable PVC conduit with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete fixed to walls /ceiling etc , including cutting chases, making good with cement mortar 1:3, terminated in and including providing modular metal flush box of suitable size with 3mm thick hylam sheet cover for fixing of switches, sockets, fan regulators etc for one light/fan/bell/buzzer point controlled by one, one way switches complete all as specified and as directed. 13 Point
180 180 All as per item No. 178 above but for one 3 pin socket outlet, 5 Amps on Independent board complete all as specified and as directed. 4 Point
181 181 All as per item No. 178 above but for one 5 Amps, 3/5 pin socket outlet on the same board with other switches complete all as specified and as directed.\n 2 Point
182 182 S&F for switch piano, 5 Amp, single pole, flush type, one way, 230 volts bearing ISI marked complete all as specified and as directed. 15 Each
183 183 S&F for socket outlet, 2 in 1, 3 pin, 5 Amps, flush type bearing ISI marked complete all as specified and as directed. 2 Each
184 184 S&F for switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts complete all as specified and as directed. 4 Each
185 185 S&F for ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed. 11 Each
186 186 S&F for stepped type (five steps) electronic fan regulator flush type complete all as specified and as directed. \nMake : Model No. 14502 of Anchor or equivalent make as per list of manufacturer. 2 Each
187 187 S&F for 18 Watt surface and wall mounting type LED batten with polycarbonate housing & integrated complete all as specified and as directed.\nMake : Havells/Philips/Bajaj/Wipro/Crompton. 4 Each
188 188 S&F for 9 Watt surface and wall mounting type LED batten with polycarbonate housing & integrated complete all as specified and as directed.\nMake : Havells/Philips/Bajaj/Wipro/Crompton. 1 Each
189 189 S&F for lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. 1 Each
190 190 S&F for LED lamp 9 Watt complete all as specified and as directed.\nMake : Havells /Philips/Bajaj /Surya/Eveready 1 Each
191 191 Supply, installing, testing and commissioning of ceilling fan, BEE 5 stars rated Brush Less Direct Current (BLDC) based, 230/240 V, 50Hz, 1200 mm sweep, power input shall be equal or below 35 Watt, speed 370 RPM, 3 nos. blades, copper winding, Power factor not less 0.9, Air delivery minimum 220 CMM, remote or electronic regulator unit for speed control, including 30cm long downrod with all fixing accessories and insulation resistance more than 2 mega ohm complete all as specified and as directed by Engr-in-Charge.\nMake : Model No: Energion HS of Crompton Greaves/Bajaj/Khaitan. 2 Each
192 192 Supply, installing, testing and commissioning of heavy duty Exhaust fan, suitable for Single Phase AC supply, earthing etc, power input 150 W, 220/240 V, 380 mm sweep size, fan speed 1400 RPM, 4 nos. blades, copper winding, Air delivery minimum 3250 CMM and including all fixing accessories complete all as specified and as directed by Engr-in-Charge.\nMake: Model No: EXHD380-4-1 of Crompton Greaves/Bajaj/Khaitan. 1 Each
193 193 S&F for factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 8 way, 240 Volts suitable for housing MCBs complete all as specified and as directed. \nMake : Cat No : DHDPSHODRW08 of Havells/L&T/Legrand. 1 Each
194 194 S&F for MCB, double pole, 240 Volts, 5 to 32 Amps, 'C' series, 10KA capacity complete all as specified and as directed. \nMake : Cat No. TDPC6-32 of HPL/L&T/Legrand/Havell's/Indoasian 1 Each
195 195 S&F for MCB, 'C' Series, SP, 240 Volts, 5 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. \nMake : Cat No. TSPC5-32 of HPL/L&T/Legrand/Havell's/Indoasian. 3 Each
196 196 S&F for 25 W LED building security new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminum housing with hight power LED as lighting source and lens imbedded PC Cover having TOP OPENING seperate driver cmpartment with IP 65 protection and inpact resistance of IK07 complete all as specified and as directed. \nMake : CAT No ENDURAPEARLSL25WSASYTOPC of Havell's/Philips/Bajaj. 4 Each