Repairs/Replacement Of Power And Distribution Cable Network Lt Panel Board And Certain Improvements Of E/M Installations At Rci And Dundigal Under Ge I Rnd Rci Hyderabad, GE I R AND D RCI, HYDERABAD-Telangana

Military Engineer Services-MES has published Repairs/Replacement Of Power And Distribution Cable Network Lt Panel Board And Certain Improvements Of E/M Installations At Rci And Dundigal Under Ge I Rnd Rci Hyderabad. Submission Date for this Tender is 25-12-2020. Electrical Maintenance Tenders in GE I R AND D RCI, HYDERABAD Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

26118097
Corrigendum : Repairs/Replacement Of Power And Distribution Cable Network Lt Panel Board And Certain Improvements Of E/M Installations At Rci And Dundigal Under Ge I Rnd Rci Hyderabad
Open Tender
Indian
Telangana
GE I R AND D RCI, HYDERABAD
25-12-2020

Tender Details

Repairs/Replacement Of Power And Distribution Cable Network Lt Panel Board And Certain Improvements Of E/M Installations At Rci And Dundigal Under Ge I Rnd Rci Hyderabad

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Dec-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-12-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 84000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIRS/REPLACEMENT OF POWER AND DISTRIBUTION CABLE NETWORK, LT PANEL BOARD AND CERTAIN IMPROVEMENTS OF E/M INSTALLATIONS AT RCI & DUNDIGAL UNDER GE (I) R&D RCI HYDERABAD
Sl No. Item Description Item Code / Make Quantity Units
1 1 Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundation, for laying of pipes/cables/poles etc., and getting out in any type of soil complete all as specified and directed. 628 CUM
2 2 All as per item No 1 but depth exceeding 1.50m and not exceeding 3.0m 2 CUM
3 3 Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each layer as in soil complete all as specified and as directed. 442 CUM
4 4 Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. 188 CUM
5 5 Supply and spreading natural river sand of approved quality for cushioning of cable laid in trenches including compacting and leveling complete all as specified and as directed.\nNote: Punned thickness will only be measured and paid. 167 CUM
6 6 Supply and laying sub class 'B' bricks, old size, laid flat perpendicular to the cable, adjacent to each other for protection of cable complete all as directed. 4560 EACH
7 7 Laying only serviceable bricks/PCC cable covers obtained perpendicular to the cable, adjacent to each other for protection of cable complete all as directed.\nNote: Bricks/cable covers obtained from item No 1 & 2 shall be used against the item. 3298 EACH
8 8 Supply and erect steel tubular swaged poles type 410 SP-55 (11 metre long) complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified in true vertical position complete including 2 coats of aluminium paint over a coat of primer on all exposed surfaces and tarring with black bituminous paint to embedded portion in PCC and providing 3 No of 15cm wide radium circular bands in red & yellow on painted portion of pole starting from 1.5m above coping at a gap of 5cm in between 2 bands including taking down old unserviceable pole of any type complete all as specified and directed.\n 5 EACH JOB
9 9 All as per item No 8 above but 410 SP-31 (9 metre long) 3 EACH JOB
10 10 M&L, PCC (1:4:8), type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete etc., for pole concreting complete all as specified and directed. 2 CUM
11 11 M&L, PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in coping to poles including necessary formwork complete all as specified and directed. 13 CUM
12 12 Dismantling of insulator of any type, any size and setting aside the serviceable insulator for reuse at site and removing unserviceable insulators from site of work complete all as directed. 36 EACH
13 13 Fixing only insulator of any type, any size complete all as directed.\nNote : Old serviceable insulators obtained from item No.12 shall be reused under this item. 9 EACH
14 14 M&L, Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green 'Two-in-series' assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and as directed. 12 EACH
15 15 M&L, Pin type, porcelain, vitreous, white, brown or green insulator 150mmu height, 150mm dia for 11000 volts grade including one galvanized mild steel spindle, two galvanized iron washers and one galvanised iron nut complete all as specified and as directed. 15 EACH
16 16 M&L in repairs, lightening arrestor, expulsion type complete with all fittings suitable for 11KV, transmission class with discharging capacity of 65KiloAmps, conforming to IS 3070 complete all as specified and as directed. 6 PER SET
17 17 Dismantling air break gang operated switches vertical/ horizontal mounted including insulators and operating mechanism for repair/replacement of broken/worn out components and insulators etc., complete all as directed. 5 EACH SET
18 18 M&L, Switch air break gang operated, triple pole, rocking type, mechanically operated, mounted on insulators and mild steel galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating upto 200Amps, 22000 Volts complete with locking arrangement, mild steel clamps, bolts, nuts and washers etc., complete all as specified and as directed. 5 EACH SET
19 19 Dismantling stay assembly complete including demolition of concrete all as directed.\nNote: Excavation and earth work will be measured separately 20 EACH SET
20 20 M&L, Stay assembly complete with 20 mm dia stay rod with accessories as shown in Electrical Plate No 1 complete all as specified and directed.\nNote: Excavation and earthwork, PCC foundation and loop insulator shall be measured and paid separately. 20 EACH SET
21 21 M&L, Galvanized stay strand of size 7/4mm to keep the pole in true vertical position complete all as specified and as directed 2 QUINTAL
22 22 M&L, Loop type insulator, vitreous porcelain, white, brown or green, large size with overall dimensions 90mm x 140mm, clearance of hole 25.5mm complete all as specified and directed. 20 EACH
23 23 Dismantling cross arms of mild steel channel or angle sections etc., complete all as directed. 5 QUINTAL
24 24 M&L, Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and including two coats of aluminium paint over a coat of primer complete all as specified and directed. 3.5 QUINTAL
25 25 Re-fixing of Cross arms, bracings, supports, clamps and back plates of structural steel sections including nuts, bolts, washers and applying one coat of aluminium paint complete all as specified and as directed. 1.5 QUINTAL
26 26 M&L, Danger notice plate HT, 25cm x 20cm size, of 1.6mm thick mild steel sheet, vitreous enamel white with letters, figures in English and Hindi and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size complete all as specified and as directed. 20 EACH
27 27 S&F in repairs, Drop Out fuse unit, 200Amp rating including polymeric post insulators and mild steel channels for 3 phase 11 KV overhead line complete all as specified and as directed 3 EACH SET
28 28 S&F, 150mm dia GI pipe light grade fixed to walls/poles or laid in trenches, road crossing etc., for protection of underground cable/earth strip including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed on walls/poles complete all as specified and directed. 18 RM
29 29 All as per item No 28 above but 100 mm dia 24 RM
30 30 M&L, Writing letters or figures (Block Roman, Italic or Indian) not exceeding 30cm high using synthetic enamel paint of approved tint complete all as directed. 800 10 No Per CM of Height
31 31 M&L, Writing stops, commas, short lines, dashes,\nhyphens, brackets, etc., using synthetic enamel paint of approved tint complete all as directed. 75 10 No
32 32 M&L in repairs, Earthing complete with copper earth plate electrode of size 600 x 600 x 3.15mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5m below normal ground level connected to copper strip 20x3mm as earth lead by means of bolts, nuts, washers and check nuts made out of galvanized iron or steel all as shown on Electrical Plate No. 3 of SSR Part-I including testing on completion complete all as specified and directed. 14 EACH JOB
33 32.01 Note 1: The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, 50mm thick RCC 1:2:4 type B-1 using 20mm graded stone aggregate cover slab reinforced with 6 Nos of 8mm dia TMT bars both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 25mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub-heading earthing, specified on Sl Page No. 422 of SSR Part-II. \n
34 32.02 2. Copper earth strip beyond 7.5m will be measured and paid separately.
35 33 M&L, copper earth strip 20 x 3mm buried in ground or fixed on wall or drawn through pipe or fixed to poles or any other indicated situation for earthing complete all as specified and as directed. 120 RM
36 34 Supplying, laying, jointing, testing and commissioning 1100 volts grade, LT XLPE insulated, PVC sheathed as per IS-7098 (Part-I), 1988 with latest amendments, galvanized steel strip or wire armoured, heavy duty, electric cables, with multistranded aluminium conductor laid in trenches/ passing through pipe/duct/road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc., including disconnecting and taking down unserviceable cable complete all as specified and directed for the following sizes:-\nNote: Earthwork Excavation, sand cushioning, GI pipe and cable protection will be measured and paid separately.
37 34.01 3.5core 185Sqmm 750 RM
38 34.02 3.5core 50Sqmm 300 RM
39 35 Supplying, laying, jointing, testing and commissioning 11000 volts grade, Earthed, HT XLPE insulated, insulation screened with extruded semi-conducting compound in combination with copper tape (0.3 KA for one second), cores laid up, PVC inner sheath with fillers, galvanized steel flat strip armoured, heavy duty, electric cables, with multistranded aluminium conductor, conductor screen with extruded semi conducting compound and overall PVC sheathed cable as per IS-7098 (Part-2) 1988 with latest amendments, laid in trenches/ passing through pipe/duct/road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc., including disconnecting and taking down unserviceable cable complete all as specified and directed for the following sizes:-\nNote: Earthwork Excavation, sand cushioning, GI pipe and cable protection will be measured and paid separately.
40 35.01 3core 120Sqmm 900 RM
41 35.02 3core 95Sqmm 220 RM
42 36 Supply and jointing new outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185sqmm for 11KV(Earthed) grade including testing complete all as specified and directed. 6 EACH JOB
43 37 All as per item No 36 above but cable of size 3core 95sqmm 4 EACH JOB
44 38 Supply and jointing new straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185sqmm for 11KV (Earthed) grade including testing complete all as specified and directed. 6 EACH JOB
45 39 Taking out burnt out/unserviceable existing cable/joint from trenches, cutting the same, supply and jointing new straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185sqmm for 11KV (Earthed) grade including testing complete all as specified and directed.\nNote: Quoted rate shall be deemed to include cost of earthwork excavation, RFR in any type of soil. Extra length of cable if any required will be measured and paid separately 18 EACH JOB
46 40 M&L, locating fault in 11 KV HT underground cable of any sizes with the help of fault locator vehicle organized from TSSPDCL/TSTRANSCO by injecting necessary high voltage to the faulty cable within 12 hours of time from time of reporting of fault all as directed by Engineer in Charge.\nNote: Quoted rate shall deemed to be included the necessary charges towards liaisoning for arranging fault locating vehicle, transportation of trained technicians and charges payable to Electricity Department. 10 EACH JOB
47 41 Supply, Install, testing and commissioning, factory made and tested, CPRI approved LT panel board indoor type, weather, dust and vermin proof, free standing floor mounting type mounted on floor, separate cable alley for all the feeders, suitable for 440Volts, 3 Phase 4wire 50Hz AC supply system, conforming to IS, IP-54 class protection and made of 2mm CRCA mild steel sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar 600Amps rating for phase and neutral 4 strips with colour coded PVC sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar 1 Each Job
48 41.01 tapings for MCCBs, copper control wiring using suitable size of PVC insulated, multi stranded copper conductors with all connected accessories, duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate accessories including dismantling the unserviceable LT panel board from the existing position after disconnection of all electrical connections complete all as specified and directed with and including the following accessories :-
49 41.02 MCCB 4pole, 400Amps, with adjustable thermal and magnetic settings, 36KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Incoming)
50 41.03 MCCB 4pole, 200Amps, with adjustable thermal and magnetic settings, 36KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 02 No (Outgoing)
51 41.04 MCCB 4pole, 100Amps, with adjustable thermal and magnetic settings, 16KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 02 No (Outgoing)
52 41.05 MCCB 4pole, 63Amps, with adjustable thermal and magnetic settings, 16KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 03 No (Outgoing)
53 41.06 Digital Ammeter 0 to 600Amps with selector switch- 01 No and 3 No of CT coil ratio 800:5 - 01 Set
54 41.07 Digital Voltmeter 0-500Volts with selector switch, 7 position and 2A HRC fuses/MCBs - 1Set
55 41.08 Indicator lamp R,Y,B LED type with 3 Nos of 2A HRC fuses - 01 Set
56 41.09 Note: Necessary arrangement shall be made for connecting and proper alignment of the panel board with the existing panel boards.
57 42 M&L, Painting to outer surface of panel board / feeder pillar box installed at various locations with one coat of synthetic enamel grey paint using spray gun machine after removing all dust and rust and writing date of painting with black synthetic enamel paint complete all as specified and directed. \nNote: The exposed surface of panel meters, lamps, switchgears to be suitably covered during painting. 280 SQM
58 43 Supply and laying un reinforced precast concrete cable cover, class HV Type 1, size 300mm x 180mm x 40mm, laid flat adjacent to each other, perpendicular to cable in trenches for protection of cable complete all as directed. 4729 EACH
59 44 Cutting of existing bituminious/PCC road or flooring/plinth protection, for laying of GI pipe in road intersection for passing of LT XLPE cable including excavation in any type of soil, returning and filling in and making good top 30cm of the trench by providing PCC 1:2:4 type B1 using 20mm graded stone aggregate to flush with existing road surface complete all as directed. 3 RM
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail