}

Construction Of New Retail Outlet At Lunglei Town ( Between Venglai To Serkawn ) Main Road , Dist . Lunglei , Mizoram . , LUNGLEI TOWN-Mizoram

Indian Oil Corporation Limited-IOCL has published Construction Of New Retail Outlet At Lunglei Town ( Between Venglai To Serkawn ) Main Road , Dist . Lunglei , Mizoram . . Submission Date for this Tender is 10-12-2020. Civil Work Tenders in LUNGLEI TOWN Mizoram. Bidders can get complete Tender details and download the document.




Tender Notice

26114577
Construction Of New Retail Outlet At Lunglei Town ( Between Venglai To Serkawn ) Main Road , Dist . Lunglei , Mizoram .
Open Tender
Indian
Mizoram
LUNGLEI TOWN
10-12-2020

Tender Details

Construction Of New Retail Outlet At Lunglei Town ( Between Venglai To Serkawn ) Main Road , Dist . Lunglei , Mizoram .

Key Value

Document Fees
Refer document
EMD
INR 159000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Construction of New Retail Outlet at Lunglei Town (Between Venglai to Serkawn) Main Road, Dist. Lunglei, Mizoram. GST applicable will be payable extra.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 DRIVEWAY WITH EDGE RESTRAINTS BI01010001010000000000000515BI0100001112
2 2 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including taking out and disposal of excavated earth within site and lift upto 1.5 m, disposed soil to be levelled and neatly dressed as directed by Engineer-in-charge. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600. BI01010001010000000000000515BI0100001113 400 M2
3 3 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth within premises BI01010001010000000000000515BI0100001114 400 M2
4 4 Supply and laying of water bound macadam of 100 mm consolidated thickness for subbase with 90 to 45 mm stone aggregate,11.2mm size screenings, chippings of stone and murrum spreading, watering and consolidating in camber with power roller complete as/specifications. BI01010001010000000000000515BI0100001115 400 M2
5 5 Supply and laying of water bound macadam in layers, each of 75 mm thick (consolidated) with 63 mm to 45 mm stone aggregate. Each layer shall be consolidated by power roller after watering, spreading chippings of stone and murrum complete as per specifications. Item includes supply of murrum 6 mm thick, watering and rolling with power roller complete with preparation of surface. Rate per Layer BI01010001010000000000000515BI0100001116 800 M2
6 6 Providing & laying factory made Grey / coloured pre-cast cement concrete, interlocking paver block of specified grade made by block making machine wih strong vibratory compaction & of approved size and design / shape, shade and manufacturers and as per IOCL's specifications. The paver blocks shall have peripheral chamfer, with average crushing strength as per IS 15658, maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881 maximum dimensional deviations of +/- 3mm on length @ width and +/- 3 mm on thickness. The job includes supplying and laying a layer of 50 mm thick clean coarse sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand, compacting with machine vibrator to required line and level, etc. complete. BI01010001010000000000000515BI0100001117
7 7 ii) M40 grade 80 mm thick Plain finish BI01010001010000000000000515BI0100001118 460 M2
8 8 Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mixer plant at Optimum Moisture Content, carriage of mixed material by tippers to work site, for all lead and lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface & compacting with vibratory power roller to achieve the desired density, complete as per specification & direction of Engineer-in-charge. BI01010001010000000000000515BI0100001119
9 9 ii) With material confirming to grade-II (size 53 mm to .075 mm) having CBR value -25,Thickness as desired BI01010001010000000000000515BI0100001120 176 M3
10 10 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. BI01010001010000000000000515BI0100001121 130 M2
11 11 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001122
12 12 iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) BI01010001010000000000000515BI0100001123 8 M3
13 13 Centering and shuttering including strutting, propping etc. and removal of form for : BI01010001010000000000000515BI0100001124
14 14 i) Foundations,footings,bases of columns, etc. for mass concrete BI01010001010000000000000515BI0100001125 100 M2
15 15 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001126
16 16 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001127 8 M3
17 17 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001128
18 18 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001129 800 KG
19 19 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001130
20 20 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001131 8 M3
21 21 Providing and laying cement plaster on surfaces with Coarse sand including curing etc. BI01010001010000000000000515BI0100001132
22 22 ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand) BI01010001010000000000000515BI0100001133 105 M2
23 23 CONSTRUCTION OF BUFFER STRIP BI01010001010000000000000515BI0100001134
24 24 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001135
25 25 i) All kinds of Soil BI01010001010000000000000515BI0100001136 4 M3
26 26 Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing : BI01010001010000000000000515BI0100001137
27 27 iv) PCC 1 Cement:2 Coarse Sand:4 Graded Stone Aggregate 40mm BI01010001010000000000000515BI0100001138 2 M3
28 28 Centering and shuttering including strutting, propping etc. and removal of form work for: BI01010001010000000000000515BI0100001139
29 29 i) Foundations,footings,bases of column BI01010001010000000000000515BI0100001140 15 M2
30 30 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001141
31 31 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001142 6 M3
32 32 Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks BI01010001010000000000000515BI0100001143 13 M2
33 33 Providing and laying cement plaster on surfaces with fine sand including curing etc. BI01010001010000000000000515BI0100001144
34 34 i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) BI01010001010000000000000515BI0100001145 35 M2
35 35 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. BI01010001010000000000000515BI0100001146 35 M2
36 36 CONSTRUCTION OF SALES BUILDING BI01010001010000000000000515BI0100001147
37 37 Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing : BI01010001010000000000000515BI0100001148
38 38 iv) PCC 1 Cement:2 Coarse Sand:4 Graded Stone Aggregate 40mm BI01010001010000000000000515BI0100001149 7 M3
39 39 vi) PCC 1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 40mm BI01010001010000000000000515BI0100001150 8 M3
40 40 Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks BI01010001010000000000000515BI0100001151 60 M2
41 41 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes providing & mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specifications. Providing & applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil BI01010001010000000000000515BI0100001152 20 M2
42 42 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001153
43 43 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001154 3500 KG
44 44 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001155
45 45 i) All kinds of Soil BI01010001010000000000000515BI0100001156 50 M3
46 46 iv) Hard Rock (Blasting Prohibited) chiesel/pneumatic drilling BI01010001010000000000000515BI0100001157 40 M3
47 47 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. BI01010001010000000000000515BI0100001158
48 48 i) Local Fine Sand within grading zone IV BI01010001010000000000000515BI0100001159 15 M3
49 49 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001160
50 50 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001161 13 M3
51 51 Providing & Laying Reinforced cement concrete work in walls (Any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level UP TO FLOOR V LEVEL excluding cost of centering, shuttering, finishing and reinforcement : BI01010001010000000000000515BI0100001162
52 52 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001163 15 M3
53 53 Centering and shuttering including strutting, propping etc. and removal of form for : BI01010001010000000000000515BI0100001164
54 54 i) Foundations,footings,bases of columns, etc. for mass concrete BI01010001010000000000000515BI0100001165 99 M2
55 55 iii) Suspended floors,roofs,landings,balconies, access platform and Shelves (Cast in situ) BI01010001010000000000000515BI0100001166 87 M2
56 56 iv) Lintels, beams plinth beams,girders bressumers and cantilevers BI01010001010000000000000515BI0100001167 21 M2
57 57 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001168
58 58 iv) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand) in superstructure in all shapes & sizes in superstructure ABOVE PLINTH & UP TO FLOOR V LEVEL BI01010001010000000000000515BI0100001169 10 M3
59 59 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001170 4 M3
60 60 viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001171 60 M2
61 61 Providing and laying cement plaster on surfaces with fine sand including curing etc. BI01010001010000000000000515BI0100001172
62 62 i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) BI01010001010000000000000515BI0100001173 250 M2
63 63 Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete BI01010001010000000000000515BI0100001174 250 M2
64 64 Supplying and laying bituminous carpet of 75mm thick for sand pad in two layers using Bitumen of grade VG-10, @100kg/Cum of sand grit of fineness modulus 3.5max. Including making slope in the sand pad including rolling the surface with Hand roller. Item includes laying of 1000 micron (1mm) black LDPE liner as per IS 2508 under the desired layer of sand BI01010001010000000000000515BI0100001175 40 M2
65 65 Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Tiles of dark shade pigment using ordinary cement BI01010001010000000000000515BI0100001176 20 M2
66 66 40mm Thick Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand:4 stone aggregate of 20mm nominal size) finished with a floating cement coat of neat including cement slurry, but excluding the cost of nosing of steps etc. complete. BI01010001010000000000000515BI0100001177 10 M2
67 67 Finishing walls with Deluxe Multi surface paint system for interiors & exteriors using Primer as per manufacturers specifications with two or more coats applied on wall @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm BI01010001010000000000000515BI0100001178 150 M2
68 68 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade with 2 or more coats BI01010001010000000000000515BI0100001179 100 M2
69 69 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. BI01010001010000000000000515BI0100001180 30 M2
70 70 Providing and fixing 100x85x5.5 mm (heavy type) bright finished brass butt hinges with necessary screws etc. complete : BI01010001010000000000000515BI0100001181 9 EA
71 71 Providing and fixing 150 mm bright finished chrome plated brass hanging type floor door stopper with rubber cushion necessary brass screws, etc. complete. to suit shutter thickness complete BI01010001010000000000000515BI0100001182 3 EA
72 72 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. BI01010001010000000000000515BI0100001183 3 EA
73 73 Providing & fixing chromium plated brass 100mm mortice latch & lock with 6 levers & a pair of lever handles with necessary screws etc complete (best make of approved quality). BI01010001010000000000000515BI0100001184 3 EA
74 74 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length,jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 Part-I & M.S. top cover of required thickness for rolling shutters:- 80x1.25mm MS laths with1.25 mm thick top cover BI01010001010000000000000515BI0100001185 10 M2
75 75 Providing and fixing ball bearing for rolling shutters. BI01010001010000000000000515BI0100001186 6 EA
76 76 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixing all complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately) BI01010001010000000000000515BI0100001187
77 77 iii) For shutters of doors, windows & ventilators with Powder coated aluminium sections including providing fixing hinges/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) BI01010001010000000000000515BI0100001188 110 KG
78 78 i) Fixed Glazing with Powder coated aluminium (minimum thickness of powder coating 50 micron) sections BI01010001010000000000000515BI0100001189 90 KG
79 79 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): BI01010001010000000000000515BI0100001190
80 80 i) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) BI01010001010000000000000515BI0100001191 24 M2
81 81 iii) With float glass panes of 8.0 mm thickness (weight not less than 20kg/sqm) BI01010001010000000000000515BI0100001192 5 M2
82 82 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately). BI01010001010000000000000515BI0100001193 5 M2
83 83 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. BI01010001010000000000000515BI0100001194
84 84 i) With stainless steel cover plate BI01010001010000000000000515BI0100001195 2 EA
85 85 Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in- charge BI01010001010000000000000515BI0100001196
86 86 i) Powder coated minimum thickness 50 micron aluminium BI01010001010000000000000515BI0100001197 2 EA
87 87 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. BI01010001010000000000000515BI0100001198
88 88 ii) 110 mm diameter BI01010001010000000000000515BI0100001199 20 M
89 89 Providing & laying vitrified floor tile in different sizes (thickness as per manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete for flooring/skirting as specified BI01010001010000000000000515BI0100001200
90 90 i) Flooring with size of Tiles 60x60Cm in cement mortar 1:4 BI01010001010000000000000515BI0100001201 20 M2
91 91 25mm Thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) BI01010001010000000000000515BI0100001202 5 M2
92 92 Providing & fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC 25 of approved design/pattern, with approved standard section & fixed to the existing window frame with C.P.brass /stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.(Only weight of grill to be measured for payment) BI01010001010000000000000515BI0100001203 10 KG
93 93 SALES BUILDING ELECTRIFICATION BI01010001010000000000000515BI0100001204
94 94 Providing following point wiring with standard wire/ cable, plug, fittings, with suitable sockets, suitable GI box with front plate etc. complete, to include circuits from distribution boards to individual point boards, suitable PVC casing capping and required accessories pulling of wires, etc. complete. BI01010001010000000000000515BI0100001205
95 95 i) Supplying and drawing following 2 pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. BI01010001010000000000000515BI0100001206 2 M
96 96 Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make BI01010001010000000000000515BI0100001207
97 97 iv) 2 x 6 sq mm + 1 x 6 sq mm earth wire BI01010001010000000000000515BI0100001208 20 M
98 98 ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire BI01010001010000000000000515BI0100001209 20 M
99 99 iii) 2 x 4 sq mm + 1 x 4 sq mm earth wire BI01010001010000000000000515BI0100001210 20 M
100 100 i) 2 x 1.5 sq mm + 1 x 1.5 sq mm earth wire BI01010001010000000000000515BI0100001211 20 M
101 101 PROVIDING INTERNAL WIRING BI01010001010000000000000515BI0100001212
102 102 ii) Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. BI01010001010000000000000515BI0100001213 25 EA
103 103 SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved including flush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer's specification and direction of Engineer In-charge. BI01010001010000000000000515BI0100001214
104 104 iv) 6 module frame BI01010001010000000000000515BI0100001215 4 EA
105 105 v) 8 module frame BI01010001010000000000000515BI0100001216 4 EA
106 106 vii) 6A Modular Switch BI01010001010000000000000515BI0100001217 25 EA
107 107 ix) 6A, 3 Pin Modular Socket BI01010001010000000000000515BI0100001218 3 EA
108 108 x) 15 A 6 Pin Modular socket BI01010001010000000000000515BI0100001219 2 EA
109 109 PROVISION OF EARTHING BI01010001010000000000000515BI0100001220
110 110 ii) Providing earthing with 80 mm dia,3.0 M long GI (Heavy duty) perforated pipe as per IS:3043 (with latest ammendment) including providing suitable earth bus for interconnection, providing a mixture of salt & charcoal, making earth pit chamber with chequered plate cover as per standard Drwng. etc. all complete as per specif. & direction of Engineer-In-charge BI01010001010000000000000515BI0100001221 1 EA
111 111 Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : BI01010001010000000000000515BI0100001222
112 112 vi) 8 S.W.G. G.I. Wire (bare) BI01010001010000000000000515BI0100001223 10 M
113 113 iii) 50 x 6 mm G.I. Strip BI01010001010000000000000515BI0100001224 20 M
114 114 PANEL BOARDS AND DISTRIBUTION BOARDS Supply, installation, testing and commissioning of cubicle type power and motor control centre panel fabricated out of 14 SWG sheet steel undergone 7 tank process,dust & vermin proof, floor mounting type, suitable for indoor use having cable entry from the bottom and having following specific components complete, control wiring etc. as per enclosed standard drawing. Any other components/hardware required to complete the panels but not mentioned here shall also be provided. Note: Both incomers should have mechanical interlock for proper & safe operation. The MCCB used for incomer feeder shall have short circuit, overload and earthfault protection and also shunt coil for ESD operation. The Bus Bar support shall be DMC/ SMC/Epoxy moulded. All equipment/components shall be mounted logically to have free access for maintenance, tightening of connections & visual inspection. All the metering equipment shall be Digital & mounted on the panel and size of meter shall be 96 mm x 96 mm. The Bus Bar shall be provided with heat shrunk PVC sleeves & all power terminals shall be stud type with properly shrouding to avoid accidental contact. Neoprene type gasket shall be provided at the doorof the panel. The enclosure of the Panel shall have IP52 degree of protection. 2 Nos earth terminal shall be provided at the Panel frame with extension link for earthing connections. Painting:The under surface shall be prepared by applying a coat of phosphate paint and coat of yellow zinc chromate primer. The under surface shall be made free from all imperfections before undertaking the finishing coat. After preparation of the under surface, the switchboard shall be spray painted with two coats of epoxy based final paint or shall be powder coated. Colour shade of final paint shall be RAL 7032. BI01010001010000000000000515BI0100001225
115 115 Medium RO, Standard drawing No. ENG/IOCL/PDIL-2. List of Componets are: (a) 1 No. MCCB (3P+N) of 100 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-100A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 100 A, Manually Operated Change over switch suitable for connection of Mains supply and 30 KVA DG Set /5 KW Solar system with required No. of MCCB (100 A,35 KA,3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 100A, 35 KA with UV coil O/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 100/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KA for supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 125 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4 (l) 9 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 3 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-3 (o) 8 Nos TP MCB of 16 A, 10 KA & 1 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement of IOCL. BI01010001010000000000000515BI0100001226 1 EA
116 116 SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved including flush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer's specification and direction of Engineer In-charge. BI01010001010000000000000515BI0100001227
117 117 xii) Fan Regulator of stepped modular type BI01010001010000000000000515BI0100001228 3 EA
118 118 CEILING FANS Supply & fixing of ceiling fan for inside of the sales building of following type: BI01010001010000000000000515BI0100001229
119 119 iii) 1200 mm sweep BI01010001010000000000000515BI0100001230 3 EA
120 120 Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001231 12 EA
121 121 Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 8 Watts with fittings and accessories, having IP20 protection class with CRCA/PC/Aluminium Extrusion housing & with UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer in charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall range from 5700 Kelvin (5665 K +/- 355 K) to 6500 Kelvin, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 80 for indoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 95 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 2kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001232 10 EA
122 122 SALES BUILDING TOILET BLOCK BI01010001010000000000000515BI0100001233
123 123 Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Tiles of dark shade pigment using ordinary cement BI01010001010000000000000515BI0100001234 6.4 M2
124 124 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade with 2 or more coats BI01010001010000000000000515BI0100001235 45 M2
125 125 Providing and fixing 100x85x5.5 mm (heavy type) bright finished brass butt hinges with necessary screws etc. complete : BI01010001010000000000000515BI0100001236 3 EA
126 126 Providing and fixing factory made 30mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75mm x 30mm having wall thickness 5mm. The styles, top & bottom rails shall have one side wall thickness of 15mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with MS tubes of size 33mm x 17mm x 1mm painted with primer, all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and rails with a cavity to receive single piece extruded 5mm PVC sheet as panel. The styles and rails shall be mitred cut and joint with help of PVC solvent cement and self tapping screws. Single piece extruded solid PVC lock rail of size 100mm x 30mm with wall thickness 5mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8mm complete as per manufacturer's specifications and direction of Engineer-in-charge BI01010001010000000000000515BI0100001237
127 127 i) Non Decorative finish BI01010001010000000000000515BI0100001238 5 M2
128 128 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogeneous fine cellular structure having smooth outer integral skin having 62mm width and 32mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38mm x 4mm & PVC solvent cement, including fixing the frame to wall with suitable dia and length anchor fastener as per manufacturer's specification and direction of Engineer-in-charge. BI01010001010000000000000515BI0100001239 15 M
129 129 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. BI01010001010000000000000515BI0100001240
130 130 ii) 110 mm diameter BI01010001010000000000000515BI0100001241 5 M
131 131 Providing & fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (minimum thickness of 5 mm) of approved make in all colours,shades except burgundy,bottle green,black of any size as approved by Engineer-in-Charge in skirting,risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade. BI01010001010000000000000515BI0100001242 35.2 M2
132 132 Providing & laying Ceramic Glazed floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) jointing with grey cement slurry@ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc. complete. BI01010001010000000000000515BI0100001243 7.8 M2
133 133 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white PVC flushing cistern including flush pipe with manually controlled device (handle lever),conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required: BI01010001010000000000000515BI0100001244
134 134 i) W.C. pan with ISI marked white solid plastic seat and lid BI01010001010000000000000515BI0100001245 1 EA
135 135 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : BI01010001010000000000000515BI0100001246
136 136 i) One urinal basin with 5 litre white P.V.C. automatic flushing cistern BI01010001010000000000000515BI0100001247 1 EA
137 137 Providing and fixing toilet paper holder : BI01010001010000000000000515BI0100001248
138 138 i) C.P. brass BI01010001010000000000000515BI0100001249 2 EA
139 139 Providing & fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : BI01010001010000000000000515BI0100001250
140 140 ii) 100mm inlet & 75mm outlet SCI S&S as per IS - 3989. BI01010001010000000000000515BI0100001251 3 EA
141 141 Providing and fixing B class G.I. Pipes complete with G.I. fittings and clamps i/c making good the walls etc. concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall for WATER and AIR BI01010001010000000000000515BI0100001252
142 142 i) 15 mm dia nominal bore BI01010001010000000000000515BI0100001253 15 M
143 143 ii) 20 mm dia nominal bore BI01010001010000000000000515BI0100001254 15 M
144 144 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. BI01010001010000000000000515BI0100001255
145 145 i) 15 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001256 15 M
146 146 ii) 20 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001257 15 M
147 147 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : BI01010001010000000000000515BI0100001258
148 148 i) 15 mm nominal bore BI01010001010000000000000515BI0100001259 1 EA
149 149 ii) 20 mm nominal bore BI01010001010000000000000515BI0100001260 1 EA
150 150 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : BI01010001010000000000000515BI0100001261
151 151 ii) White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap BI01010001010000000000000515BI0100001262 3 EA
152 152 Providing and fixing brass bib cock of approved quality : BI01010001010000000000000515BI0100001263
153 153 i) 15 mm nominal bore BI01010001010000000000000515BI0100001264 6 EA
154 154 Providing and fixing brass stop cock of approved quality : BI01010001010000000000000515BI0100001265
155 155 i) 15 mm nominal bore BI01010001010000000000000515BI0100001266 6 EA
156 156 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : BI01010001010000000000000515BI0100001267
157 157 i) 25 mm nominal bore BI01010001010000000000000515BI0100001268 1 EA
158 158 Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank BI01010001010000000000000515BI0100001269 500 L
159 159 Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make BI01010001010000000000000515BI0100001270
160 160 iv) 2 x 6 sq mm + 1 x 6 sq mm earth wire BI01010001010000000000000515BI0100001271 20 M
161 161 ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire BI01010001010000000000000515BI0100001272 20 M
162 162 iii) 2 x 4 sq mm + 1 x 4 sq mm earth wire BI01010001010000000000000515BI0100001273 20 M
163 163 i) 2 x 1.5 sq mm + 1 x 1.5 sq mm earth wire BI01010001010000000000000515BI0100001274 20 M
164 164 PROVIDING INTERNAL WIRING BI01010001010000000000000515BI0100001275
165 165 i) Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. BI01010001010000000000000515BI0100001276 8 EA
166 166 SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved including flush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer's specification and direction of Engineer In-charge. BI01010001010000000000000515BI0100001277
167 167 iv) 6 module frame BI01010001010000000000000515BI0100001278 2 EA
168 168 vii) 6A Modular Switch BI01010001010000000000000515BI0100001279 8 EA
169 169 ix) 6A, 3 Pin Modular Socket BI01010001010000000000000515BI0100001280 2 EA
170 170 x) 15 A 6 Pin Modular socket BI01010001010000000000000515BI0100001281 2 EA
171 171 EXHAUST FANS Supply and fixing of exhaust fan including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters. (The job does not include making suitable cut out in the wall for fixing the fan). BI01010001010000000000000515BI0100001282
172 172 ii) 9" dia light duty, make Khaitan or equivalent BI01010001010000000000000515BI0100001283 3 EA
173 173 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001284
174 174 iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) BI01010001010000000000000515BI0100001285 2 M3
175 175 Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing : BI01010001010000000000000515BI0100001286
176 176 vi) PCC 1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 40mm BI01010001010000000000000515BI0100001287 1.5 M3
177 177 Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks BI01010001010000000000000515BI0100001288 26 M2
178 178 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes providing & mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specifications. Providing & applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil BI01010001010000000000000515BI0100001289 3.5 M2
179 179 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001290
180 180 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001291 700 KG
181 181 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001292
182 182 i) All kinds of Soil BI01010001010000000000000515BI0100001293 32 M3
183 183 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. BI01010001010000000000000515BI0100001294
184 184 i) Local Fine Sand within grading zone IV BI01010001010000000000000515BI0100001295 5.5 M3
185 185 Providing & Laying Reinforced cement concrete work in walls (Any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level UP TO FLOOR V LEVEL excluding cost of centering, shuttering, finishing and reinforcement : BI01010001010000000000000515BI0100001296
186 186 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001297 6 M3
187 187 Centering and shuttering including strutting, propping etc. and removal of form for : BI01010001010000000000000515BI0100001298
188 188 i) Foundations,footings,bases of columns, etc. for mass concrete BI01010001010000000000000515BI0100001299 41 M2
189 189 iii) Suspended floors,roofs,landings,balconies, access platform and Shelves (Cast in situ) BI01010001010000000000000515BI0100001300 20 M2
190 190 iv) Lintels, beams plinth beams,girders bressumers and cantilevers BI01010001010000000000000515BI0100001301 5 M2
191 191 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001302
192 192 iv) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand) in superstructure in all shapes & sizes in superstructure ABOVE PLINTH & UP TO FLOOR V LEVEL BI01010001010000000000000515BI0100001303 6 M3
193 193 viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001304 20 M2
194 194 Providing and laying cement plaster on surfaces with fine sand including curing etc. BI01010001010000000000000515BI0100001305
195 195 i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) BI01010001010000000000000515BI0100001306 75 M2
196 196 Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete BI01010001010000000000000515BI0100001307 75 M2
197 197 Supplying and laying bituminous carpet of 75mm thick for sand pad in two layers using Bitumen of grade VG-10, @100kg/Cum of sand grit of fineness modulus 3.5max. Including making slope in the sand pad including rolling the surface with Hand roller. Item includes laying of 1000 micron (1mm) black LDPE liner as per IS 2508 under the desired layer of sand BI01010001010000000000000515BI0100001308 11 M2
198 198 Finishing walls with Deluxe Multi surface paint system for interiors & exteriors using Primer as per manufacturers specifications with two or more coats applied on wall @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm BI01010001010000000000000515BI0100001309 70 M2
199 199 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. BI01010001010000000000000515BI0100001310 9 M2
200 200 Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001311 6 EA
201 201 Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 8 Watts with fittings and accessories, having IP20 protection class with CRCA/PC/Aluminium Extrusion housing & with UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer in charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall range from 5700 Kelvin (5665 K +/- 355 K) to 6500 Kelvin, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 80 for indoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 95 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 2kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001312 3 EA
202 202 SIDE DRAIN BI01010001010000000000000515BI0100001313
203 203 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001314
204 204 i) All kinds of Soil BI01010001010000000000000515BI0100001315 58.88 M3
205 205 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001316
206 206 vii) 1:3:6(1 Cement : 3 Fine Sand : 6 Graded stone aggregate of 40mm) BI01010001010000000000000515BI0100001317 3.68 M3
207 207 Centering and shuttering including strutting, propping etc. and removal of form work for: BI01010001010000000000000515BI0100001318
208 208 i) Foundations,footings,bases of column BI01010001010000000000000515BI0100001319 35 M2
209 209 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001320
210 210 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001321 23 M3
211 211 Providing and laying cement plaster on surfaces with Coarse sand including curing etc. BI01010001010000000000000515BI0100001322
212 212 ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand) BI01010001010000000000000515BI0100001323 230 M2
213 213 Providing Neat cement punning BI01010001010000000000000515BI0100001324 115 M2
214 214 GRATING CULVERT ON BOTH APPROACHES & OPE BI01010001010000000000000515BI0100001325
215 215 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001326
216 216 i) All kinds of Soil BI01010001010000000000000515BI0100001327 80 M3
217 217 iv) Hard Rock (Blasting Prohibited) chiesel/pneumatic drilling BI01010001010000000000000515BI0100001328 120 M3
218 218 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001329
219 219 iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) BI01010001010000000000000515BI0100001330 1.5 M3
220 220 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001331
221 221 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001332 7 M3
222 222 Centering and shuttering including strutting, propping etc. and removal of form work for: BI01010001010000000000000515BI0100001333
223 223 i) Foundations,footings,bases of column BI01010001010000000000000515BI0100001334 75 M2
224 224 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001335
225 225 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001336 700 KG
226 226 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: BI01010001010000000000000515BI0100001337 900 KG
227 227 Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks BI01010001010000000000000515BI0100001338 15 M2
228 228 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001339
229 229 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001340 2 M3
230 230 Providing and laying cement plaster on surfaces with Coarse sand including curing etc. BI01010001010000000000000515BI0100001341
231 231 ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand) BI01010001010000000000000515BI0100001342 50 M2
232 232 Providing Neat cement punning BI01010001010000000000000515BI0100001343 50 M2
233 233 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty BI01010001010000000000000515BI0100001344
234 234 iv) 300 mm dia. R.C.C. pipe BI01010001010000000000000515BI0100001345 6 M
235 235 CONSTRUCTION OF CANOPY (16x8) BI01010001010000000000000515BI0100001346
236 236 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: BI01010001010000000000000515BI0100001347 7040 KG
237 237 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001348
238 238 i) All kinds of Soil BI01010001010000000000000515BI0100001349 40 M3
239 239 iv) Hard Rock (Blasting Prohibited) chiesel/pneumatic drilling BI01010001010000000000000515BI0100001350 180 M3
240 240 Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks BI01010001010000000000000515BI0100001351 24 M2
241 241 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001352
242 242 vi) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 40mm) BI01010001010000000000000515BI0100001353 2 M3
243 243 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001354
244 244 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001355 1125 KG
245 245 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001356
246 246 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001357 11 M3
247 247 Centering and shuttering including strutting, propping etc. and removal of form work for: BI01010001010000000000000515BI0100001358
248 248 i) Foundations,footings,bases of column BI01010001010000000000000515BI0100001359 26 M2
249 249 Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge : BI01010001010000000000000515BI0100001360
250 250 v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate BI01010001010000000000000515BI0100001361 24 EA
251 251 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. BI01010001010000000000000515BI0100001362
252 252 iii) 160 mm diameter PVC Rain water pipe BI01010001010000000000000515BI0100001363 20 M
253 253 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions,total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: BI01010001010000000000000515BI0100001364
254 254 ii) Inside dimensions 500x700 mm and 45 cm deep for pipeline with one or two inlets with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 BI01010001010000000000000515BI0100001365 2 EA
255 255 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty BI01010001010000000000000515BI0100001366
256 256 iv) 300 mm dia. R.C.C. pipe BI01010001010000000000000515BI0100001367 30 M
257 257 Providing and fixing  Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of Cold rolled steel confirming to IS:513-2008 of base metal thickness 0.50 mm, having Yield Stress of Min. 275 MPa. Steel surface shall have hot dip metallic coating of Al-Zinc alloy comprising 55% Alluminium, 43.5% Zinc and 1.5% Silicon as per the ASTM-A792M, with total mass of coating on both sides shall be 150 gms/sqm. The steel shall have organic coating with Silicon Modified Polyester (SMP) /Super Durable Polyester (SDP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns SMP /SDP paint over 5-7 microns epoxy primer) and back side 8-10 Microns SMP/SDP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.58 MM. Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m or as desired by Engineer-in-charge. BI01010001010000000000000515BI0100001368
258 258 i) Profile Sheet for roofing BI01010001010000000000000515BI0100001369 128 M2
259 259 iii) Plain sheet for Flashings/ Aprons (Upto 600 mm) BI01010001010000000000000515BI0100001370 58 M
260 260 iv) Plain Sheet for Gutter (600 mm over all girth) BI01010001010000000000000515BI0100001371 16 M
261 261 ii) Plain Sheet for Ridges (500 - 600mm). BI01010001010000000000000515BI0100001372 10 M
262 262 Providing and fixing  150F/200F flush panel,(pre-coated steel) False Ceiling made of  Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa & 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of  thickness of 25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure. BI01010001010000000000000515BI0100001373 128 M2
263 263 Supply and Fixing of under Canopy Recessed mounted Discrete LED (Light Emitting Diode) Light fixture of 80 watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour Temperature) shall be in the range of 5665K +/- 355K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001374 13 EA
264 264 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items BI01010001010000000000000515BI0100001375
265 265 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS BI01010001010000000000000515BI0100001376 300 M
266 266 CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. BI01010001010000000000000515BI0100001377
267 267 vii) 3 Core x 2.5 sq. mm BI01010001010000000000000515BI0100001378 20 EA
268 268 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items BI01010001010000000000000515BI0100001379
269 269 xiv) 4 Core x 16 sq. mm Aluminium Cable FRLS BI01010001010000000000000515BI0100001380 20 M
270 270 Supply & Fixing of Weatherproof (IP-65) Thermoplastic Cable Junction Box with terminal block fitted inside the box suitable for following cable sizes. BI01010001010000000000000515BI0100001381
271 271 i) for 2.5 sq.mm. cable entry size with 9 terminals BI01010001010000000000000515BI0100001382 6 EA
272 272 FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. BI01010001010000000000000515BI0100001383
273 273 vii) 3 Core x 2.5 sq. mm BI01010001010000000000000515BI0100001384 16 EA
274 274 x) 8 S.W.G. Cu. Wire BI01010001010000000000000515BI0100001385 100 M
275 275 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty BI01010001010000000000000515BI0100001386
276 276 ii) 150 mm dia. R.C.C. pipe BI01010001010000000000000515BI0100001387 30 M
277 277 Finishing walls with Deluxe Multi surface paint system for interiors & exteriors using Primer as per manufacturers specifications with two or more coats applied on wall @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm BI01010001010000000000000515BI0100001388 350 M2
278 278 MCB DISTRIBUTION BOARD INCLUSIVE OF 3- PHASE MCB Supply & fixing of MCB Distribution Board double door type inclusive of MCB, Three Phase, as per Approved Make of following types: (MCB - 10KA Breaking Capacity) BI01010001010000000000000515BI0100001389
279 279 INSTALLATION OF 2X20 KL TANK BI01010001010000000000000515BI0100001390
280 280 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. BI01010001010000000000000515BI0100001391
281 281 iii) 160 mm diameter PVC Rain water pipe BI01010001010000000000000515BI0100001392 12 M
282 282 Supplying and installation of the following threaded BI01010001010000000000000515BI0100001393
283 283 i) 80 mm dia Aluminium camlock coupling - Male only BI01010001010000000000000515BI0100001394 2 EA
284 284 Transportation of equipment from one location to another location including enroute all taxes, levies and unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank same shall be loaded by the tank fabrication contractor) BI01010001010000000000000515BI0100001395
285 285 iii) 15/20 KL Tank with fittings : 0 - 30 Km BI01010001010000000000000515BI0100001396 2 LS
286 286 iv) 15/20 KL Tank with fittings: Add extra for each addtnl. Km above 30km BI01010001010000000000000515BI0100001397 660 KM
287 287 Installation of supplied 20 KL Tank as per specified drawings as per work description but excluding all works of kerb wall and Gasket for manhole including painting / doping with Shalimastic HD as applicable as per specifications complete. RCC works wherever mentioned shall be of grade M20 BI01010001010000000000000515BI0100001398
288 288 iv) In brick masonry pit with RCC matt under driveway including RCC top slab as per standard Drg. ENG/318. Manhole cover plates and frame to be paid separately . BI01010001010000000000000515BI0100001399 2 LS
289 289 Supply and Laying of 80 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling & back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125. BI01010001010000000000000515BI0100001400 20 M
290 290 Supply, fabrication, laying and testing of MS, BLACK, ERW, threaded pipes, heavy class conforming to IS 1239, PART I as per IOCL Specifications including pipeline fittings like bends, tee etc as required and as directed for Above Ground pipeline including surface preparation according to standard SSPC ST2 and painting with 2 coats of red oxide zinc phosphate primer and 2 coats of Synthetic enamel / aluminium finish paint as per IOCL specifications BI01010001010000000000000515BI0100001401
291 291 ii) S/L Threaded A/G HD MS Pipes of 80 mm dia with fittings,Painting BI01010001010000000000000515BI0100001402 5 M
292 292 Providing & fixing flexible copper cable PVC insulated of 16sqmm for connecting the earth grid/earth strip with the crocodile clip i/c cost of 1 no. crocodile clip (for tanker earthing & other job) BI01010001010000000000000515BI0100001403 2 EA
293 293 Supply and fixing Pressure Vacuum Valves of 2 inches for fixing to the Vent Pipes of Underground MS tanks. The valve should be in closed position at normal operating pressure of the tank. The Valve shall be capable for activation at set pressure of 3" ± 0.5 water column to release excess pressure of tank to the atmosphere and open at vacuum of 8" ± 2.0 water column to induce the atmosphere pressure to the tank. PV valve should be diaphragm of dead weight or spring loaded type or combination of any. The weight of the PV valve shall not exceed 2.0 kg. top of the valve shall be provided with cover/cap/ weather hood to prevent the entry of rain water. Valve material,Cover and adopter shall be of Aluminium/polypropylene, diaphragm if used should be of Neoprene, O ring should be of rubber/neoprene, Net/Mesh Pressure puppet ,Vacuum puppet,screws and spring should be of stainless steel. Suitable adopter with one end fitted with valve and the other end should have threading for fixing on Vent pipe of 40mm. PV valves shall have: UL 842 certification of CARB approval or test certificate from any Govt.lab. PV valve shall have PESO approval. BI01010001010000000000000515BI0100001404 1 EA
294 294 Supply and installation of ‘U’ type CS bend on the vent pipes including painting as per specifications and supplying and brazing wire mesh of 11 mesh per linear centi-meter of non-corrosive metal in two layers on both ends. BI01010001010000000000000515BI0100001405
295 295 i) Supply & installation of U type CS bend on vent pipe of 80 mm dia BI01010001010000000000000515BI0100001406 1 EA
296 296 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001407
297 297 iv) Hard Rock (Blasting Prohibited) chiesel/pneumatic drilling BI01010001010000000000000515BI0100001408 80 M3
298 298 MPD AND STP INSTALLATION BI01010001010000000000000515BI0100001409
299 299 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001410
300 300 i) All kinds of Soil BI01010001010000000000000515BI0100001411 10 M3
301 301 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. BI01010001010000000000000515BI0100001412
302 302 i) Local Fine Sand within grading zone IV BI01010001010000000000000515BI0100001413 2 M3
303 303 Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing : BI01010001010000000000000515BI0100001414
304 304 iv) PCC 1 Cement:2 Coarse Sand:4 Graded Stone Aggregate 40mm BI01010001010000000000000515BI0100001415 1.5 M3
305 305 Supplying and fixing of 10mm thick mirror polished black granite tiles for pump island edges etc. over 12mm thick CM 1:4 including cost of all materials and labour etc. complete. BI01010001010000000000000515BI0100001416 9 M2
306 306 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. BI01010001010000000000000515BI0100001417
307 307 iv) Granite of any colour and shade having Area of slab over 0.50 sqm BI01010001010000000000000515BI0100001418 10 M2
308 308 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001419
309 309 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001420 6 M3
310 310 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001421
311 311 viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001422 4 M2
312 312 Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks BI01010001010000000000000515BI0100001423 10 M2
313 313 Supply and Laying of 50 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling & back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125. BI01010001010000000000000515BI0100001424 50 M
314 314 Supply, fabrication, laying and testing of MS black, ERW welded, pipes, heavy class conforming to IS 1239, PART I as per IOCL specifications including pipeline fittings like bends, tee etc as required and as directed for Underground pipeline with doping BI01010001010000000000000515BI0100001425
315 315 iii) S/L Welded U/G HD MS Pipes of 50mm dia with fittings,doping BI01010001010000000000000515BI0100001426 20 M
316 316 Supply, fabrication, laying and testing of MS, BLACK, ERW, threaded pipes, heavy class conforming to IS 1239, PART I as per IOCL specifications including pipeline fittings like bends, tee etc as required and as directed for Underground pipeline with doping BI01010001010000000000000515BI0100001427
317 317 iii) S/L Threaded U/G HD MS Pipes of 50 mm dia with fittings,doping BI01010001010000000000000515BI0100001428 12 M
318 318 Supplying and installation of the following threaded Caps conforming to detailed specification BI01010001010000000000000515BI0100001429
319 319 i) S/I of Threaded caps of 50 mm dia for dip pipe BI01010001010000000000000515BI0100001430 2 EA
320 320 Supply and installation of screwed type gun metal valves as per IOC specifications: Ball Valve BI01010001010000000000000515BI0100001431
321 321 iii) S/I Screwed type GM Ball Valve of 50 mm dia BI01010001010000000000000515BI0100001432 6 EA
322 322 Installation of supplied Multi Product Pumps / Dispensers on pump island as per manufacturers installation manual, drawings, including supplying, providing necessary frame of ISMC 100, foundation bolts, supplying and filling required quantity of dry sand in pit(s) below the pump BI01010001010000000000000515BI0100001433
323 323 i) 2 product - 4 nozzle MPPs/MPDs BI01010001010000000000000515BI0100001434 2 EA
324 324 Transportation of equipment from one location to another location including enroute all taxes, levies and unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank same shall be loaded by the tank fabrication contractor) BI01010001010000000000000515BI0100001435
325 325 xii) MPD/MPP pumps upto 2 nos., 0-30 Km BI01010001010000000000000515BI0100001436 2 LS
326 326 xii) MPD/MPP pumps upto 2 nos., Add extra for every additional Km above 30km BI01010001010000000000000515BI0100001437 350 KM
327 327 viii) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos,0-30 Km BI01010001010000000000000515BI0100001438 2 LS
328 328 ix) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos, Add extra for every additional Km above 30km BI01010001010000000000000515BI0100001439 350 KM
329 329 Supply & welding slip-on flanges conforming to IS2062 GrA, ANSI B16.5, Class#150 with 3 runs of weld outside and one run of weld inside the flanges as per specifications and standard Drg.enclosed herein BI01010001010000000000000515BI0100001440
330 330 ii) S/W Slipon flanges of 80 mm dia conforming to IS2062 GrA, ANSI B16.5,Class 150 as per specifications and standard Drg.enclosed herein BI01010001010000000000000515BI0100001441 4 EA
331 331 ii) S/I of Threaded Nipple of 50 mm dia BI01010001010000000000000515BI0100001442 1 EA
332 332 ii) S/I of Threaded Nipple of 50 mm dia BI01010001010000000000000515BI0100001443 2 EA
333 333 ii) S/I of Threaded Union of 50 mm BI01010001010000000000000515BI0100001444 2 EA
334 334 Supplying and installation of the following threaded Union conforming to detailed specification BI01010001010000000000000515BI0100001445
335 335 Installation of Corporation supplied Standard Submersible Turbine Pump on the existing Manhole Cover as per drawing and direction of Engineer in Charge BI01010001010000000000000515BI0100001446 2 EA
336 336 Providing alteration to Manhole Covers for Fixing Submersible Turbine Including Fixing of 100mm diax 150 to 200mm long C class threaded Barrel Nipple , 100mm dia x 100 mm long coupler , 2 nos 100mm dia Class 150 threaded MS flange, 3mm thick packing sheet, nuts and bolts, 3mm thick permanite oil packing gasket to manhole cover, cutting of the manhole cover for fixing nipples etc. at workshop including transportation etc. BI01010001010000000000000515BI0100001447 2 EA
337 337 DU ELECTRIFICATION BI01010001010000000000000515BI0100001448
338 338 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty BI01010001010000000000000515BI0100001449
339 339 ii) 150 mm dia. R.C.C. pipe BI01010001010000000000000515BI0100001450 35 M
340 340 CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. BI01010001010000000000000515BI0100001451
341 341 vi) 3 Core x 1.5 sq. mm. BI01010001010000000000000515BI0100001452 4 EA
342 342 vii) 3 Core x 2.5 sq. mm BI01010001010000000000000515BI0100001453 4 EA
343 343 FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. BI01010001010000000000000515BI0100001454
344 344 vii) 3 Core x 2.5 sq. mm BI01010001010000000000000515BI0100001455 8 EA
345 345 vi) 3 Core x 1.5 sq. mm. BI01010001010000000000000515BI0100001456 8 EA
346 346 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items BI01010001010000000000000515BI0100001457
347 347 iii) 3 Core x 1.5 sq. mm. (copper) BI01010001010000000000000515BI0100001458 200 M
348 348 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS BI01010001010000000000000515BI0100001459 500 M
349 349 Supplying and fixing of following MCBs with necessery inter connections on existing DB, Panel board etc. BI01010001010000000000000515BI0100001460
350 350 ii) Upto 32A DP MCB BI01010001010000000000000515BI0100001461 10 EA
351 351 Supply and installation of MCB distribution board having Double door complete with tinned cu bus bar, neutral bus bar, earth bar, din bar, interconnection, earthing etc. without incoming isolator and MCBs BI01010001010000000000000515BI0100001462
352 352 iii) 2+12 way SPN BI01010001010000000000000515BI0100001463 2 EA
353 353 Supplying and fixing 12 volt Charged LA battery of approved make for Electronic dispensing pumps including giving necessery electrical connection for the following AH ratings. BI01010001010000000000000515BI0100001464
354 354 i) S/I of 12 Volt, 7AH Charged LA battery of approved make with stand BI01010001010000000000000515BI0100001465 2 EA
355 355 SINGLE SERVO VOLTAGE STABILISER Supply and fixing of 230V, Single phase, AC Servo voltage stabilizer of approved makes,(Range - 180 - 250 minimum) shall be provided for Individual dispensing pump as per IE Regulation and as per specification BI01010001010000000000000515BI0100001466
356 356 iv) 5KVA stabilizer BI01010001010000000000000515BI0100001467 2 EA
357 357 CONSTANT VOLTAGE TRANSFORMER Supplying, installation, testing and commissioning of single phase, air cooled constant voltage transformer of approved make having input voltage range of 180-260V and output voltage of 220/230V with sine wave output wave form and having automatic current limiting and short circuit protection including all accessories complete (for displays) for the following VA ratings. BI01010001010000000000000515BI0100001468
358 358 iii) 500VA CVT BI01010001010000000000000515BI0100001469 2 EA
359 359 SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved including flush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer's specification and direction of Engineer In-charge. BI01010001010000000000000515BI0100001470
360 360 viii) 15 A Modular switch BI01010001010000000000000515BI0100001471 6 EA
361 361 x) 15 A 6 Pin Modular socket BI01010001010000000000000515BI0100001472 6 EA
362 362 SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved including flush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer's specification and direction of Engineer In-charge. BI01010001010000000000000515BI0100001473
363 363 iv) 6 module frame BI01010001010000000000000515BI0100001474 3 EA
364 364 Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make BI01010001010000000000000515BI0100001475
365 365 ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire BI01010001010000000000000515BI0100001476 50 M
366 366 Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : BI01010001010000000000000515BI0100001477
367 367 vi) 8 S.W.G. G.I. Wire (bare) BI01010001010000000000000515BI0100001478 80 M
368 368 PROVISION OF EARTHING BI01010001010000000000000515BI0100001479
369 369 ii) Providing earthing with 80 mm dia,3.0 M long GI (Heavy duty) perforated pipe as per IS:3043 (with latest ammendment) including providing suitable earth bus for interconnection, providing a mixture of salt & charcoal, making earth pit chamber with chequered plate cover as per standard Drwng. etc. all complete as per specif. & direction of Engineer-In-charge BI01010001010000000000000515BI0100001480 2 EA
370 370 Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : BI01010001010000000000000515BI0100001481
371 371 i) 50 x 10mm G.I. Strip BI01010001010000000000000515BI0100001482 90 M
372 372 ii) 32 x 6 mm G.I.strip BI01010001010000000000000515BI0100001483 120 M
373 373 v) 25 x 3 mm GI strip BI01010001010000000000000515BI0100001484 250 M
374 374 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: BI01010001010000000000000515BI0100001485 30 KG
375 375 Lettering with black japan paint of approved brand & manufacture and (unit/letter/cm ht) BI01010001010000000000000515BI0100001486 150 EA
376 376 YARD LIGHTING (5 NOS) BI01010001010000000000000515BI0100001487
377 377 Providing and laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen BI01010001010000000000000515BI0100001488 55 M
378 378 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001489
379 379 i) All kinds of Soil BI01010001010000000000000515BI0100001490 7.5 M3
380 380 Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing : BI01010001010000000000000515BI0100001491
381 381 iv) PCC 1 Cement:2 Coarse Sand:4 Graded Stone Aggregate 40mm BI01010001010000000000000515BI0100001492 1 M3
382 382 Centering and shuttering including strutting, propping etc. and removal of form work for: BI01010001010000000000000515BI0100001493
383 383 i) Foundations,footings,bases of column BI01010001010000000000000515BI0100001494 20 M2
384 384 Supplying and providing 100mm square hensel weather proof junction box for emblem pole/ light pole/yard light BI01010001010000000000000515BI0100001495 7 EA
385 385 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items BI01010001010000000000000515BI0100001496
386 386 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS BI01010001010000000000000515BI0100001497 180 M
387 387 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items BI01010001010000000000000515BI0100001498
388 388 xviii) 3.5 Core x 50 sq. mm Aluminium Cable FRLS BI01010001010000000000000515BI0100001499 22 M
389 389 FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. BI01010001010000000000000515BI0100001500
390 390 vii) 3 Core x 2.5 sq. mm BI01010001010000000000000515BI0100001501 5 EA
391 391 Supplying & drawing inside the poles 3 core 2.5 sq.mm PVC insulated flexible copper conductor, fixing of junction box at the pole base (excluding supply of JB), making all connections on both ends, all complete as per specification and direction of Engineer In-charge. BI01010001010000000000000515BI0100001502
392 392 ii) "L" Pole BI01010001010000000000000515BI0100001503 5 EA
393 393 OCTAGONAL POLES Supply & Fixing of Octagonal Poles of following type (Civil job shall be paid separatly) : BI01010001010000000000000515BI0100001504
394 394 iii) S/E of 5 Meter high galvanised Octagonal pole with top 60mm(A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 210 x 210 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides) BI01010001010000000000000515BI0100001505 5 EA
395 395 FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. BI01010001010000000000000515BI0100001506
396 396 xviii) 3.5 Core x 50 sq. mm BI01010001010000000000000515BI0100001507 5 EA
397 397 Supply, fitting, fixing of arm bracket, tubular type, 38mm/50mm dia on pole including painting, all complete. BI01010001010000000000000515BI0100001508
398 398 i) S/E Arm " L " bracket 38/50mm dia on pole, as per specifications and direction of Engineer in charge BI01010001010000000000000515BI0100001509 5 EA
399 399 Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001510 5 EA
400 400 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001511
401 401 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001512 500 KG
402 402 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001513
403 403 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001514 5 M3
404 404 AIR FACILITY BI01010001010000000000000515BI0100001515
405 405 Tyre Inflator Supply & installation of Digital tyre inflator which is microprocessor based, automatic air pressure controller with solenoid controlled nozzle for automatic fill and release functions. Complete with weather proof cabinet, 3 digit LED displays with backlight illuminations i.e. one for actual tyre pressure and another for set pressure. Air filter, remote controller, cables, PVC hose pipe and working pressure upto 10bar (Excluding civil work for foundation,etc.) BI01010001010000000000000515BI0100001516 1 EA
406 406 Providing and fixing B class G.I. pipes complete with G.I. fittings & clamps, i/c cutting & making good the walls etc. Internal work Exposed on wall. BI01010001010000000000000515BI0100001517
407 407 iii) 25 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001518 10 M
408 408 FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. BI01010001010000000000000515BI0100001519
409 409 vii) 3 Core x 2.5 sq. mm BI01010001010000000000000515BI0100001520 2 EA
410 410 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items BI01010001010000000000000515BI0100001521
411 411 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS BI01010001010000000000000515BI0100001522 100 M
412 412 Air compressor Supply and installation of horizontal air compressor assembly with delivery pressure of 12 kg/sq cm equipped with pressure gauge, non- return/safety/drain/delivery valves, automatic cut-off switch and suitable electrical connections & all standard accessories, including civil works: BI01010001010000000000000515BI0100001523
413 413 iii) Horizontal air compressor Assembly of 5 HP (160-220 LITRES) including civil works BI01010001010000000000000515BI0100001524 1 EA
414 414 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: BI01010001010000000000000515BI0100001525 200 KG
415 415 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001526
416 416 i) All kinds of Soil BI01010001010000000000000515BI0100001527 1 M3
417 417 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001528
418 418 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001529 3 M3
419 419 Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins,rafters & trusses & including cutting to size & shape wherever required:- 1.00mm thick G.S. Sheet with zinc coating not less than 275gm/m² BI01010001010000000000000515BI0100001530 15 M2
420 420 Providing and laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen BI01010001010000000000000515BI0100001531 30 M
421 421 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001532
422 422 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001533 2 M3
423 423 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001534
424 424 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001535 300 KG
425 425 Providing and laying cement plaster on surfaces with Coarse sand including curing etc. BI01010001010000000000000515BI0100001536
426 426 ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand) BI01010001010000000000000515BI0100001537 11 M2
427 427 Finishing walls with Deluxe Multi surface paint system for interiors & exteriors using Primer as per manufacturers specifications with two or more coats applied on wall @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm BI01010001010000000000000515BI0100001538 11 M2
428 428 MONOLITH FOUNDATION BI01010001010000000000000515BI0100001539
429 429 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001540
430 430 i) All kinds of Soil BI01010001010000000000000515BI0100001541 15 M3
431 431 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. BI01010001010000000000000515BI0100001542
432 432 i) Local Fine Sand within grading zone IV BI01010001010000000000000515BI0100001543 1 M3
433 433 Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing : BI01010001010000000000000515BI0100001544
434 434 iv) PCC 1 Cement:2 Coarse Sand:4 Graded Stone Aggregate 40mm BI01010001010000000000000515BI0100001545 1 M3
435 435 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001546
436 436 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001547 6 M3
437 437 Centering and shuttering including strutting, propping etc. and removal of form work for: BI01010001010000000000000515BI0100001548
438 438 i) Foundations,footings,bases of column BI01010001010000000000000515BI0100001549 18 M2
439 439 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001550
440 440 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001551 600 KG
441 441 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001552
442 442 viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001553 1.5 M2
443 443 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall BI01010001010000000000000515BI0100001554
444 444 vi) 50 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001555 1 M
445 445 Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge : BI01010001010000000000000515BI0100001556
446 446 v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate BI01010001010000000000000515BI0100001557 12 EA
447 447 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items BI01010001010000000000000515BI0100001558
448 448 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS BI01010001010000000000000515BI0100001559 40 M
449 449 CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. BI01010001010000000000000515BI0100001560
450 450 vii) 3 Core x 2.5 sq. mm BI01010001010000000000000515BI0100001561 2 EA
451 451 Providing, fixing, testing and commissioning of FLP junction box of approved make for cable connection/ jointing. BI01010001010000000000000515BI0100001562
452 452 i) For cables 2.5 to 4 sqmm XLPE / AYFY BI01010001010000000000000515BI0100001563 1 EA
453 453 Supplying and fixing of following MCBs with necessery inter connections on existing DB, Panel board etc. BI01010001010000000000000515BI0100001564
454 454 ii) Upto 32A DP MCB BI01010001010000000000000515BI0100001565 2 EA
455 455 Supplying and fixing of 10mm thick mirror polished black granite tiles for pump island edges etc. over 12mm thick CM 1:4 including cost of all materials and labour etc. complete. BI01010001010000000000000515BI0100001566 3.6 M2
456 456 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. BI01010001010000000000000515BI0100001567
457 457 iv) Granite of any colour and shade having Area of slab over 0.50 sqm BI01010001010000000000000515BI0100001568 1.8 M2
458 458 Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001569 2 EA
459 459 RAIN WATER HARVESTING BI01010001010000000000000515BI0100001570
460 460 Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank BI01010001010000000000000515BI0100001571 500 L
461 461 Supplying and Installation of 0.5 to 2 HP Single phase Mono block Water pump (Bronze impeller). BI01010001010000000000000515BI0100001572
462 462 iii) 1 HP BI01010001010000000000000515BI0100001573 1 EA
463 463 iii) 25 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001574 20 M
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail