Construction Of 1000 Mt Capacity Paddy Godown At Purba Kadua O Lalpur Skus Ltd District - Purba Mednipu
Tender Overview
Project Description
Construction Of 1000 Mt Capacity Paddy Godown At Purba Kadua O Lalpur Skus Ltd District - Purba Mednipu
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-Dec-2020 | Corrigendum | Other | 18-Dec-2020 |
BOQ
| Name of Work: Construction of 1000 MT capacity Paddy Godown at PURBA KADUA O LALPUR SKUS LTD District - Purba Mednipu | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | MAIN GODOWN BUILDING\nEarth work in excavation of foundation trenches or drains . In all sorts of soil (including mixed soil but excluding laterite or sandstone )including removing . Spreading or stacking the spils within a lead of 75 m . As directed . The item includes necessary trimming the sides of trenches. leveling. dressing and ramming the bottom . bailing out water as required complete.\n(a) Depth of excavation not exceeding 1,500 mm | BI01010001010000000000000515BI0100001129 | 4.32 | % Cu.M |
| 2 | 2 | (b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm but not requiring shoring | BI01010001010000000000000515BI0100001130 | 1.37 | % Cu.M |
| 3 | 3 | Earth work in filling in foundation trenches or plinth with good earth. in layers not exceeding 150 mm . Including watering and ramming etc. layer by layer complete . (Payment to be made on the basis of measurement of finished quantity of work)\n(a) With earth obtained from excavation of foundation. | BI01010001010000000000000515BI0100001131 | 2.86 | % Cu.M |
| 4 | 4 | Filling in foundation or plinth by silver sand in\nlayers not exceeding 150 mm as directed and\nconsolidating the same by thorough saturation with\nwater, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity | BI01010001010000000000000515BI0100001132 | 5.96 | % Cu.M |
| 5 | 5 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand | BI01010001010000000000000515BI0100001133 | 740 | Sqm |
| 6 | 6 | (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) (A) Pakur Variety (1:3:6)\nIn ground floor | BI01010001010000000000000515BI0100001134 | 75 | Cu.M |
| 7 | 7 | Anti termite treatment to bottom surface ( in case of masonry foundation and basements) and the sides ( upto a height of 300 mm. from bottom) of the excavation trenches with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. area. The work shall be carried out as per specification described in 6.2.1. of code IS-6313 (part -II) 1981.( Mode of measurment will be the plan area of foundation treated.)\n | BI01010001010000000000000515BI0100001135 | 469.8 | Sqm |
| 8 | 8 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than\n300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using\nconcrete mixture\n(b) M 25 Grade\nFOUNDATION | BI01010001010000000000000515BI0100001136 | 262 | cum |
| 9 | 9 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs .beams .columns.lintels curved or straight including fitting .fixing and striking out after completion of worka.(upto roof of ground floor)\n(c ) Steel shuttering or 9 to 12 mm. thick approved quality ply board shuttering in any concrete work \nupto 1st fl | BI01010001010000000000000515BI0100001137 | 875 | Sq.M. |
| 10 | 10 | Reinforcement for reinforced concrete work in the all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary ),cutting to requisite length . hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.\n(a) For works in foundation, basement and upto roof of ground floor /upto 4 m.\n (ì) Tor steel/Mild steel \nIII. OTHER MANUFACTURERS NOT\nSPECIFIED\nFoundation UPTO 1ST floor ( gf roof) | BI01010001010000000000000515BI0100001138 | 34 | M.T |
| 11 | 11 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.\nNOTE:Cement 0.152 cu.m per100 sq. | BI01010001010000000000000515BI0100001139 | 145 | Sqm |
| 12 | 12 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).\nUsing grey cement\n(iii) 35 mm. thick | BI01010001010000000000000515BI0100001140 | 469.8 | Sqm |
| 13 | 13 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. | BI01010001010000000000000515BI0100001141 | 469.8 | Sqm |
| 14 | 14 | Brick work with 1st class bricks in cement mortar (1:6)\n(a) In foundation and plinth | BI01010001010000000000000515BI0100001142 | 45 | cum |
| 15 | 15 | (b) In superstructure, ground floor | BI01010001010000000000000515BI0100001143 | 68 | cum |
| 16 | 16 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4)\ngr floor | BI01010001010000000000000515BI0100001144 | 75 | sqm |
| 17 | 17 | Plaster (to wall,floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface. Including throating, nosing and drip course where necessary \n(¡) With 6:1 cement mortar (internal), 15mm plaster\nGR.FL | BI01010001010000000000000515BI0100001145 | 445 | Sq.M |
| 18 | 18 | (ii) With 1:4 cement mortar, ceiling, 10 mm thk\nGR. FLOOR | BI01010001010000000000000515BI0100001146 | 150 | Sq.M |
| 19 | 19 | (¡) With 6:1 cement mortar ( external)\n20 mm. thick plaster\ngr floor | BI01010001010000000000000515BI0100001147 | 620 | Sq.M |
| 20 | 20 | Labour for Chipping of concrete surface before taking up Plastering work. | BI01010001010000000000000515BI0100001148 | 150 | sqm |
| 21 | 21 | (a) Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete. \nGround Floor | BI01010001010000000000000515BI0100001149 | 15 | Sq.M. |
| 22 | 22 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.\n(b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only]\nGR FL | BI01010001010000000000000515BI0100001150 | 15 | sqm |
| 23 | 23 | Supplying best Indian Sheet glass 5 mm thick including cutting to required sizes,setting on putty bases and fitted and fixed with teak glazing beads (19 mm x 12 mm) including putty and nails as necessary complete. (In all floors for internal wall & upto 6 m height for external wall) | BI01010001010000000000000515BI0100001151 | 15 | sqm |
| 24 | 24 | (vi) steel peg stay 300 mm long including fitting and fixing | BI01010001010000000000000515BI0100001152 | 38 | each |
| 25 | 25 | (v) Two point nose aluminium handle including fitting and fixing | BI01010001010000000000000515BI0100001153 | 38 | each |
| 26 | 26 | Square or hexagonal mesh netting made with 18 B.W.G. galvanised wire, fitted and fixed complete as per design (excluding the supporting framework but including local sal wood battens of size 37.5mmx25mm).\nIn ground floor\n(b) 25mm mesh at gr fl | BI01010001010000000000000515BI0100001154 | 15 | sqm |
| 27 | 27 | Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S.flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. | BI01010001010000000000000515BI0100001155 | 15 | sqm |
| 28 | 28 | M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to\nrequisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental\nchages (such as electricity, labour insurance) etc. complete\nPayment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by\nadding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate\nfor each additional floor or 4m. beyond the initial 8 m. or part thereof\nc) Span beyond 20 Mtr and up to 30 Mtr | BI01010001010000000000000515BI0100001156 | 21.15 | MT |
| 29 | 29 | Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed\n16mm bolt\n(b) 450 mm long | BI01010001010000000000000515BI0100001157 | 22 | each |
| 30 | 30 | (iv) 32 mm dia:\n(b) 500 mm long | BI01010001010000000000000515BI0100001158 | 36 | each |
| 31 | 31 | ROOFING AND SIDE SHEETING\nSupplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make(excluding the supporting frame work) fitted and fixed with55 mm & 25 mm self tapping screw, EPDM Washer 16 mm\ndia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work).\na) With 0.5 mm thick sheet | BI01010001010000000000000515BI0100001159 | 485 | Sq.M. |
| 32 | 32 | Galvanised corrugated iron sheet work (excluding thesupporting frame work) fitted and fixed with 10 mm. dia J or L hook-bolts, limpet and bitumen washers and putty complete with 150 mm. end lap and one corrugation minimum side lap. (Payment to be made on area of finished work)(GCI sheet to\nbe supplied by contractor\n(ii) In wall:-\nc) With 0.80 mm thick sheet | BI01010001010000000000000515BI0100001160 | 56 | sqm |
| 33 | 33 | Galvanised iron sheet ridging fitted with necessary bolts,\nscrews, washers etc complete.(225mm end lapping\n(B) 450 mm lapping each way\n(c) With 0.80 mm sheet | BI01010001010000000000000515BI0100001161 | 25 | metre |
| 34 | 34 | Galvanised iron sheets valley gutter with perimeter not less than 750 mm with 225 mm lap each way fitted and fixed with necessary bolts, nuts, screws, etc.complete. Valley gutter made of 0.63 mm. thick sheets. (300mm End lapping) | BI01010001010000000000000515BI0100001162 | 50 | metre |
| 35 | 35 | Applying decorative cement based paint of approved quality after mpreparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification\n(iii) Two coats\ngr. Floor | BI01010001010000000000000515BI0100001163 | 670 | sqm |
| 36 | 36 | 1st floor | BI01010001010000000000000515BI0100001164 | ||
| 37 | 37 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)\n(i) Internal surface (All floors\n(b) Two coats \ni) Water based interior grade Acrylic Primer\nGR FL | BI01010001010000000000000515BI0100001165 | 6.7 | % sqm |
| 38 | 38 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC\n(a) TWO Coat\nGR.FL | BI01010001010000000000000515BI0100001166 | 6.2 | % sqm |
| 39 | 39 | Protective and Decorative Acrylic exterior emulsion paint of approvedN quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.\nb) Premium 100% Acrylic Emulsion\nGR FLOOR | BI01010001010000000000000515BI0100001167 | 620 | Sq.M |
| 40 | 40 | a) Priming one coat on steel or other metal surface with synthetic oilbound primer of approved quality including smoothening surfaces by sand\npapering etc. | BI01010001010000000000000515BI0100001168 | 1200 | sqm |
| 41 | 41 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary\n(b) On steel or other metal surface\nWith super gloss (hi-gloss\n(iv) Two coats (with any shade except white) | BI01010001010000000000000515BI0100001169 | 1200 | sqm |
| 42 | 42 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match withGI Pipes as per IS : 1239 (Part -I). with all necessary accessories,specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrewreducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will\nbe made seperately\n(a) For Exposed Work\n200 mm | BI01010001010000000000000515BI0100001170 | 25 | metre |
| 43 | 43 | (D) Long Bend (90 Degree) | BI01010001010000000000000515BI0100001171 | 8 | EACH |
| 44 | 44 | ROAD\nBox cutting or filling in Road embankment in all sorts of soil including spreading the spoils properly over the flank as necessary or on berm to approximate grade & camber and rolling the sub-grade with power roller to proper camber and grade as per direction and satisfaction of Engineer-in-charge including uprooting and removing plants and jungles when and where necessary\n(a) Depth up to 150 mm. | BI01010001010000000000000515BI0100001172 | 277.5 | sqm |
| 45 | 45 | (b) For each additional Depth of 150mm and part therof | BI01010001010000000000000515BI0100001173 | 277.5 | sqm |
| 46 | 46 | Extra for manual compaction of earth by rammers / hand roller in 250 mm layers including watering etc. if required. (Borrow pit measurement | BI01010001010000000000000515BI0100001174 | 555 | cum |
| 47 | 47 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity\nDO BY FINE SAND | BI01010001010000000000000515BI0100001175 | 1.11 | %cum |
| 48 | 48 | Supplying and laying brick Khoa of ordinary bats of size (38 mmx 63 mm)of approved quality in 100 mm layer (loose) filling in gaps with small ones rammed and compact as directed true to level and grade | BI01010001010000000000000515BI0100001176 | 185 | sqm |
| 49 | 49 | (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) (B) With N.B. Variety stone metal | BI01010001010000000000000515BI0100001177 | 18.5 | cum |
| 50 | 50 | Batch mix concrete of M30 Grade with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than\n300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using\nconcrete mixture\n(b) M 25 Grade | BI01010001010000000000000515BI0100001178 | 27.75 | cum |
| 51 | 51 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs .beams .columns.lintels curved or straight including fitting .fixing and striking out after completion of worka.(upto roof of ground floor)\n(c ) Steel shuttering or 9 to 12 mm. thick approved quality ply board shuttering in any concrete work | BI01010001010000000000000515BI0100001179 | 30.6 | Sq.M. |
| 52 | 52 | Reinforcement for reinforced concrete work in the all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary ),cutting to requisite length . hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.\n(a) For works in foundation, basement and upto roof of ground floor /upto 4 m. | BI01010001010000000000000515BI0100001180 | 1.26 | MT |
| 53 | 53 | ELECTRICAL WORK\nMCB DISTRIBUTION BOARD\nSupplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.\n125A (Siemens or equivalent) | BI01010001010000000000000515BI0100001181 | 1 | NOS |
| 54 | 54 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment\n12 way (Legrand or equivalent) | BI01010001010000000000000515BI0100001182 | 1 | NOS |
| 55 | 55 | 125A (Legrand or equivalent) | BI01010001010000000000000515BI0100001183 | 1 | NOS |
| 56 | 56 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.\n2+8 way Enclosure (607711). | BI01010001010000000000000515BI0100001184 | 4 | NOS |
| 57 | 57 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment\n4 way Enclosure (607715). | BI01010001010000000000000515BI0100001185 | 1 | NOS |
| 58 | 58 | MCB\nSupplying and fixing 240/415V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection\n6-32 A SP. | BI01010001010000000000000515BI0100001186 | 5 | NOS |
| 59 | 59 | 6-32 A DP. | BI01010001010000000000000515BI0100001187 | 3 | NOS |
| 60 | 60 | 32 A TP. | BI01010001010000000000000515BI0100001188 | 3 | NOS |
| 61 | 61 | 32 A FP. | BI01010001010000000000000515BI0100001189 | 2 | NOS |
| 62 | 62 | MCB ENCLOSURE\nSupplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment\n2 Way. | BI01010001010000000000000515BI0100001190 | 5 | NOS |
| 63 | 63 | WIRING WITH PVC INSULATED & UNSHEATHED SINGLE CORE STRANDED COPPER WIRE ‘'FR' – IN PVC RIGID CONDUIT 'FR' (ISI MARKED) ON WALL/CEILING\nDistribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required\n2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC | BI01010001010000000000000515BI0100001191 | 100 | METER |
| 64 | 64 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC. | BI01010001010000000000000515BI0100001192 | 125 | METER |
| 65 | 65 | 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC. | BI01010001010000000000000515BI0100001193 | 135 | METER |
| 66 | 66 | Wiring With PVC Insulated & Unsheathed Single Core Stranded Copper Wire ‘'FR' – in PVC Rigid Conduit 'FR' (ISI Marked) on wall/ceiling\nDistribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish.\nOne light control by 1 switch | BI01010001010000000000000515BI0100001194 | 12 | POINT |
| 67 | 67 | Two light control by 1 switch | BI01010001010000000000000515BI0100001195 | 8 | POINT |
| 68 | 68 | Three light control by 1 switch | BI01010001010000000000000515BI0100001196 | 8 | POINT |
| 69 | 69 | Supply & Fixing 240 V, 6/16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire\netc. | BI01010001010000000000000515BI0100001197 | 4 | NOS |
| 70 | 70 | 1NO BLANK PLATE.(1M) | BI01010001010000000000000515BI0100001198 | 26 | NOS |
| 71 | 71 | Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or\ntwilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required\n1 output per phase and suitable for single phase supply | BI01010001010000000000000515BI0100001199 | ||
| 72 | 72 | MV CABLE\nSupply of 1.1KV 4Cx6sqmm XLPE Armoured Al. cable as directed by EIC. | BI01010001010000000000000515BI0100001200 | 50 | METER |
| 73 | 73 | Supply of 1.1KV 3.5Cx50sqmm XLPE Armoured Al. cable as directed by EIC. | BI01010001010000000000000515BI0100001201 | 25 | METER |
| 74 | 74 | SCHEDULE OF RATES FOR LAYING OF XLPE/PVC INSULATED AND ARMOURED CABLES\nLAYING ON WALL / SURFACE WITH SADDLES / CLAMPS\nLaying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F\nMS saddles with earthing attachment in 10 SWG GI (Hot Dip)\nWire, making holes etc. as necy. mending good damages and\npainting | BI01010001010000000000000515BI0100001202 | 150 | Mtr |
| 75 | 75 | Laying through Underground Trech \nLaying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed | BI01010001010000000000000515BI0100001203 | 40 | Mtr |
| 76 | 76 | COMPRESSION GLAND\nSupplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :\nFor 4 core - upto 6 sqmm. | BI01010001010000000000000515BI0100001204 | 16 | EACH |
| 77 | 77 | For 3.5 core - upto 50 sqmm | BI01010001010000000000000515BI0100001205 | 4 | EACH |
| 78 | 78 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :\n4 core 6 sqmm cable. | BI01010001010000000000000515BI0100001206 | 16 | SET |
| 79 | 79 | 3½ core 50 sqmm cable | BI01010001010000000000000515BI0100001207 | 4 | SET |
| 80 | 80 | FINISHING COPPER WIRE ENDS\nFinishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.\n2.5sqmm. | BI01010001010000000000000515BI0100001208 | 600 | SET |
| 81 | 81 | 4sqmm. | BI01010001010000000000000515BI0100001209 | 85 | SET |
| 82 | 82 | SURFACE LUMINAIRE\nSupply of surface mounted LED light fixture with 2x20Watt LED Lamp.( CROMPTON-IGP162LT8-16 + LGT8-20-865-2 OR APPROVED BY EIC) | BI01010001010000000000000515BI0100001210 | 10 | NOS |
| 83 | 83 | Supply of surface mounted LED light fixture with 1x20Watt LED Lamp.( CROMPTON-IGP161LT8-16 + LGT8-20-865-2 OR APPROVED BY EIC) | BI01010001010000000000000515BI0100001211 | 2 | NOS |
| 84 | 84 | Supply of wall mounted outdoor type 60watt LED Floodlight fixture. (CROMPTON- LFL-60-CDL/60-M OR APPROVED BY EIC) | BI01010001010000000000000515BI0100001212 | ||
| 85 | 85 | Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener. | BI01010001010000000000000515BI0100001213 | 12 | EACH |
| 86 | 86 | Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. | BI01010001010000000000000515BI0100001214 | 15 | EACH |
| 87 | 87 | Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required | BI01010001010000000000000515BI0100001215 | ||
| 88 | 88 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. | BI01010001010000000000000515BI0100001216 | ||
| 89 | 89 | EARTHING INSTALLATION – WITH PIPE ELECTRODE :\nEarthing with 50 mm dia GI pipe (TATA-Medium) 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level (2Nos for Electrical equipment and 2nos for MS structure with shed). | BI01010001010000000000000515BI0100001217 | 1 | SET |
| 90 | 90 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. | BI01010001010000000000000515BI0100001218 | 1 | ITEM |
| 91 | 91 | Extra for treatment of soil by using salt & charcoal or coke for plate electrode. | BI01010001010000000000000515BI0100001219 | 1 | ITEM |
| 92 | 92 | EARTH CONTINUTY CONDUCTOR:\nConnecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages\nNo. 8 SWG | BI01010001010000000000000515BI0100001220 | 25 | Mtr |
| 93 | 93 | EQUIPMENT EARTHING:\nConnecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. | BI01010001010000000000000515BI0100001221 | 15 | Mtr |
| 94 | 94 | Add 12% G.S.T. + 1 % L.W.Cess | BI01010001010000000000000515BI0100001222 | 1 | Nos |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender