| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Appendix A: Park and Building | BI01010001010000000000000515BI0100001113 | ||
| 2 | 1.01 | 2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared | BI01010001010000000000000515BI0100001114 | 1956 | sqm |
| 3 | 1.02 | 15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar | BI01010001010000000000000515BI0100001115 | 12 | cum |
| 4 | 1.03 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil | BI01010001010000000000000515BI0100001116 | 60.548 | cum |
| 5 | 1.04 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | BI01010001010000000000000515BI0100001117 | 16.107 | cum |
| 6 | 1.05 | 7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001118 | 51.266 | cum |
| 7 | 1.06 | 5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size | BI01010001010000000000000515BI0100001119 | 8.763 | cum |
| 8 | 1.07 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | BI01010001010000000000000515BI0100001120 | 23.82 | sqm |
| 9 | 1.08 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | BI01010001010000000000000515BI0100001121 | 876.3 | kilogram |
| 10 | 1.09 | 50.6.7.2 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. | BI01010001010000000000000515BI0100001122 | 47.062 | cum |
| 11 | 1.1 | 26.43 : Providing and fixing internal wall panels on Light gauge steel frame work with12.5mm thick gypsum plaster board conforming IS 2095:2011 fixed on 8mmthick fiber cement board conforming to IS 14862:2000 of category III type B(High pressure steam cured) as per standard sizes fixed with self-drilling / tapingscrews / fasteners @ 60cm c/c of approved make, Screws shall be of countersunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from25 to 45 mm. Proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of framework to be paid for separately) | BI01010001010000000000000515BI0100001123 | 48 | sqm |
| 12 | 1.11 | 9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. | BI01010001010000000000000515BI0100001124 | 31 | metre |
| 13 | 1.12 | 9.122.1 : Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames. | BI01010001010000000000000515BI0100001125 | 6.72 | sqm |
| 14 | 1.13 | 9.122.2 : Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001126 | 3.781 | sqm |
| 15 | 1.14 | 6.13.2 : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement : 4 coarse sand) | BI01010001010000000000000515BI0100001127 | 17.82 | sqm |
| 16 | 1.15 | 4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001128 | 6.241 | cum |
| 17 | 1.16 | 8.2.1.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm | BI01010001010000000000000515BI0100001129 | 70.878 | sqm |
| 18 | 1.17 | 15.18 : Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,boltd, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. | BI01010001010000000000000515BI0100001130 | 3360 | kg |
| 19 | 1.18 | 15.28.1 : Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet | BI01010001010000000000000515BI0100001131 | 168 | sqm |
| 20 | 1.19 | 10.16.2 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes | BI01010001010000000000000515BI0100001132 | 8280.5 | kg |
| 21 | 1.2 | 12.48 : Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) | BI01010001010000000000000515BI0100001133 | 252 | sqm |
| 22 | 1.21 | od222054/2019_2020 : Providing & fixing on roof pressed clay ceiling tiles 30x25cm size of 20 mm nominal thickness and of approved size and as per approved pattern | BI01010001010000000000000515BI0100001134 | 252 | sqm |
| 23 | 1.22 | 12.49 : Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ). | BI01010001010000000000000515BI0100001135 | 48 | metre |
| 24 | 1.23 | 50.6.1.1 : Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete | BI01010001010000000000000515BI0100001136 | 10 | cum |
| 25 | 1.24 | 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | BI01010001010000000000000515BI0100001137 | 89.42 | sqm |
| 26 | 1.25 | 13.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) | BI01010001010000000000000515BI0100001138 | 39.42 | sqm |
| 27 | 1.26 | 13.48.3 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture | BI01010001010000000000000515BI0100001139 | 300 | sqm |
| 28 | 1.27 | 13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work | BI01010001010000000000000515BI0100001140 | 153.601 | sqm |
| 29 | 1.28 | 16.70.2 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I wire of dia 4 mm. PVC coated to achieve outer dia. not less than 5 mm in required colour and shade | BI01010001010000000000000515BI0100001141 | 97.5 | sqm |
| 30 | 1.29 | 16.83 : Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. | BI01010001010000000000000515BI0100001142 | 923.75 | sqm |
| 31 | 1.3 | 16.1 : Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. | BI01010001010000000000000515BI0100001143 | 923.75 | sqm |
| 32 | 1.31 | 16.78.2 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBRValue-25 | BI01010001010000000000000515BI0100001144 | 184.75 | cum |
| 33 | 1.32 | od47430/2020_2021 : Providing and laying rough finish granite stone (sadarhalli) flooring in required design and pattern (180 x 90 cm or nearest)in linear as well as curvillenear all complete as per the architrctural drawing with 50mm thick stone slab over 50mm thick base of stone aggregates of size 6mm etc.complete as specified and as directed by the engineer in charge | BI01010001010000000000000515BI0100001145 | 966 | sqm |
| 34 | 1.33 | 14.83 : Hacking of CC flooring including cleaning for surface etc. complete as perdirection of the Engineer-in-Charge. | BI01010001010000000000000515BI0100001146 | 97.5 | sqm |
| 35 | 1.34 | 11.41.1 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm. | BI01010001010000000000000515BI0100001147 | 104.85 | sqm |
| 36 | 2 | Appendix B: Toilet Block | BI01010001010000000000000515BI0100001148 | ||
| 37 | 2.01 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil | BI01010001010000000000000515BI0100001149 | 70.03 | cum |
| 38 | 2.02 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | BI01010001010000000000000515BI0100001150 | 8.565 | cum |
| 39 | 2.03 | 7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001151 | 8.398 | cum |
| 40 | 2.04 | 50.6.7.2 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. | BI01010001010000000000000515BI0100001152 | 6.291 | cum |
| 41 | 2.05 | 6.13.2 : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement : 4 coarse sand) | BI01010001010000000000000515BI0100001153 | 5.738 | sqm |
| 42 | 2.06 | 6.15 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry. | BI01010001010000000000000515BI0100001154 | 5.738 | sqm |
| 43 | 2.07 | 5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size | BI01010001010000000000000515BI0100001155 | 0.969 | cum |
| 44 | 2.08 | 5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). | BI01010001010000000000000515BI0100001156 | 0.524 | cum |
| 45 | 2.09 | 5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers | BI01010001010000000000000515BI0100001157 | 9.69 | sqm |
| 46 | 2.1 | 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | BI01010001010000000000000515BI0100001158 | 0.72 | sqm |
| 47 | 2.11 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | BI01010001010000000000000515BI0100001159 | 149.3 | kilogram |
| 48 | 2.12 | 9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood | BI01010001010000000000000515BI0100001160 | 0.259 | cum |
| 49 | 2.13 | 9.5.1.1 : Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak wood35 mm thick shutters | BI01010001010000000000000515BI0100001161 | 4.92 | sqm |
| 50 | 2.14 | 10.30.2 : Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with :5.5 mm thick glass panes | BI01010001010000000000000515BI0100001162 | 0.72 | sqm |
| 51 | 2.15 | 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | BI01010001010000000000000515BI0100001163 | 77.445 | sqm |
| 52 | 2.16 | 11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. | BI01010001010000000000000515BI0100001164 | 13.273 | sqm |
| 53 | 2.17 | 11.39 : Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS: 15622, of approved make in colours White, Ivory, Grey, fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete. | BI01010001010000000000000515BI0100001165 | 21.168 | sqm |
| 54 | 2.18 | 13.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) | BI01010001010000000000000515BI0100001166 | 77.445 | sqm |
| 55 | 2.19 | 10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes | BI01010001010000000000000515BI0100001167 | 1030.43 | kg |
| 56 | 2.2 | 12.48 : Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) | BI01010001010000000000000515BI0100001168 | 34.348 | sqm |
| 57 | 2.21 | 12.49 : Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ). | BI01010001010000000000000515BI0100001169 | 16.05 | metre |
| 58 | 2.22 | od222054/2019_2020 : Providing & fixing on roof pressed clay ceiling tiles 30x25cm size of 20 mm nominal thickness and of approved size and as per approved pattern | BI01010001010000000000000515BI0100001170 | 34.348 | sqm |
| 59 | 3 | Appendix C: Plumbing and Sanitary fittings | BI01010001010000000000000515BI0100001171 | ||
| 60 | 3.01 | 50.18.7.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge 20 mm dia 10 Kgf/cm2- Internal work - Exposed on wall | BI01010001010000000000000515BI0100001172 | 60 | metre |
| 61 | 3.02 | 50.18.7.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall | BI01010001010000000000000515BI0100001173 | 60 | metre |
| 62 | 3.03 | 50.18.7.4.2 : Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall | BI01010001010000000000000515BI0100001174 | 60 | metre |
| 63 | 3.04 | 50.18.7.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall | BI01010001010000000000000515BI0100001175 | 50 | metre |
| 64 | 3.05 | 17.2.1 : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid | BI01010001010000000000000515BI0100001176 | 2 | each |
| 65 | 3.06 | 17.7.1 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | BI01010001010000000000000515BI0100001177 | 2 | each |
| 66 | 3.07 | 18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore | BI01010001010000000000000515BI0100001178 | 4 | each |
| 67 | 3.08 | 18.55.1 : Providing and fixing PTMT stop cock of approved quality and colour.15 mm nominal bore, 86 mm long, weighing not less than 88 gms | BI01010001010000000000000515BI0100001179 | 4 | each |
| 68 | 3.09 | 18.64 : Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms. | BI01010001010000000000000515BI0100001180 | 2 | no |
| 69 | 3.1 | 18.65 : Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fittings arrangements, weighing not less than 106 gms. | BI01010001010000000000000515BI0100001181 | 2 | each |
| 70 | 3.11 | 50.17.1.4 : Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. | BI01010001010000000000000515BI0100001182 | 2 | no |
| 71 | 3.12 | 51.19.ST4 : Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately)<br>\n4. 35 to 50 flush capacity | BI01010001010000000000000515BI0100001183 | 1 | each |
| 72 | 3.13 | 19.32.1 : Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | BI01010001010000000000000515BI0100001184 | 1 | each |
| 73 | 4 | Appendix D: Seaters | BI01010001010000000000000515BI0100001185 | ||
| 74 | 4.01 | od88504/2020_2021 : Supplying, fitting, fixing and handing over the garden benches (Victoria Bench - Product Code :PGGD18) or equivalent as specified in the drawings of make ARIHANT or equivalent acceptable to engineer -in - chief, with prior approval, fully complete at site with all accessories, labours, power supply etc. | BI01010001010000000000000515BI0100001186 | 10 | each |
| 75 | 5 | Appendix E: Landscape | BI01010001010000000000000515BI0100001187 | ||
| 76 | 5.01 | 30.2.12 : Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts. | BI01010001010000000000000515BI0100001188 | 140 | sqm |
| 77 | 5.02 | od91748/2020_2021 : Supplying and planting of approved ground cover at required spacing as shown in drawing. Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting from the date of planting operating etc.(2)Small lily | BI01010001010000000000000515BI0100001189 | 100 | each |
| 78 | 5.03 | od90256/2020_2021 : Supplying and planting of approved trees species of a height 2.0m to 2.5m, at the specified location as shown in the drawing.Rate shall include Cost of plants, soil work inclusive of red soil, sand and manure mix staking and planting of trees sapling, replacement of dead trees and for providing a pit size 75 x 75 x 75 cm and maintainance till the competion of project work.( 1).Plumeria Alba | BI01010001010000000000000515BI0100001190 | 5 | each |
| 79 | 5.04 | od90257/2020_2021 : Supplying and planting of approved shrubs at required spacing as shown in drawing. Rate shall include cost of plants soil work,manure and fertilizers used in top dressing, chemical and machanical pest control, staking and maintaining the planting till it is handed over from the date of planting labour charges, pest control operating etc. (9)Oleander tall | BI01010001010000000000000515BI0100001191 | 10 | each |
| 80 | 5.05 | od90258/2020_2021 : Supplying and planting of approved shrubs at required spacing as shown in drawing. Rate shall include cost of plants soil work,manure and fertilizers used in top dressing, chemical and machanical pest control, staking and maintaining the planting till it is handed over from the date of planting labour charges, pest control operating etc. (1)Aglonema | BI01010001010000000000000515BI0100001192 | 100 | each |
| 81 | 5.06 | 30.2.33 : Providing and fixing Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and even, watering with sprinkler | BI01010001010000000000000515BI0100001193 | 140 | sqm |
| 82 | 6 | Appendix F: Electrification | BI01010001010000000000000515BI0100001194 | ||
| 83 | 6.01 | 1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC\ninsulated copper conductor single core cable in surface / recessed medium class PVC conduit,\nwith modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS\nPVC insulated copper conductor single core cable etc as required.Group C | BI01010001010000000000000515BI0100001195 | 7 | point |
| 84 | 6.02 | 1.34 : Supplying and fixing brass batten/ angle holder including connection etc. as required. | BI01010001010000000000000515BI0100001196 | 5 | each |
| 85 | 6.03 | 1.12 : Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single corecable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulatedcopper conductor single core cable for loop earthing as required. | BI01010001010000000000000515BI0100001197 | 2 | metre |
| 86 | 6.04 | 1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire | BI01010001010000000000000515BI0100001198 | 10 | metre |
| 87 | 6.05 | od103707/2020_2021 : Supplying & fixing 6W LED bulb in the existing batten/angle holder. | BI01010001010000000000000515BI0100001199 | 5 | each |
| 88 | 6.06 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | BI01010001010000000000000515BI0100001200 | 7 | each |
| 89 | 6.07 | 2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole | BI01010001010000000000000515BI0100001201 | 1 | each |
| 90 | 6.08 | 2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole | BI01010001010000000000000515BI0100001202 | 1 | each |
| 91 | 6.09 | 2.3.1 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door | BI01010001010000000000000515BI0100001203 | 1 | each |
| 92 | 6.1 | 2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual\ncurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps | BI01010001010000000000000515BI0100001204 | 1 | each |
| 93 | 6.11 | 9.1.2 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.2 X 10 sq. mm (19mm) | BI01010001010000000000000515BI0100001205 | 38 | set |
| 94 | 6.12 | 90.12.1.3 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). | BI01010001010000000000000515BI0100001206 | 200 | metre |
| 95 | 6.13 | 90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required | BI01010001010000000000000515BI0100001207 | 1 | each |
| 96 | 6.14 | 90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required | BI01010001010000000000000515BI0100001208 | 200 | metre |
| 97 | 6.15 | 1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings). | BI01010001010000000000000515BI0100001209 | 2 | each |
| 98 | 6.16 | 2.10.5 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral | BI01010001010000000000000515BI0100001210 | 1 | each |
| 99 | 6.17 | 90.4.8 : Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. | BI01010001010000000000000515BI0100001211 | 2 | each |
| 100 | 6.18 | od103708/2020_2021 : Supply and fitting167x125mmx82mm ) Sintex cable junction box ( on existing lamp post using suitable clamps. | BI01010001010000000000000515BI0100001212 | 18 | each |
| 101 | 6.19 | od103709/2020_2021 : Supply, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.300/305mm light duty | BI01010001010000000000000515BI0100001213 | 2 | each |
| 102 | 6.2 | od103710/2020_2021 : Supply Conveyance, installation, testing and commissioning of new generation post top environment friendly, energy saving, long life, aesthetically designed with symmetrical light distribution spun aluminium landscape luminaire with high power LED as light source. 25W 5600K, with IP65 protection suitable for 76mm dia. pole. (Havells Ruby clear or equivalent) | BI01010001010000000000000515BI0100001214 | 18 | each |
| 103 | 6.21 | od106351/2020_2021 : Supply and fixing 32A, 4way connector in the existing junction box | BI01010001010000000000000515BI0100001215 | 18 | each |
| 104 | 6.22 | od103711/2020_2021 : Supply and fixing 32A, 2way neutral link mounted on DMC/SMC base with connections in existing meter board. | BI01010001010000000000000515BI0100001216 | 18 | each |
| 105 | 6.23 | od136499/2020_2021 : Supplying & fixing Cast iron lamp pole of height 4mtrs. base dia.250mm and top dia.75mm (weight 110kg. Arox. with provision for fixing MCB and cably entry/exit at bottom made of FG15 grade cast iron with MRF apoxy black finish over a coat of zinc chromate base on existing concrete foundation using foundation bolts, nuts and washers. | BI01010001010000000000000515BI0100001217 | 18 | each |
| 106 | 6.24 | od136500/2020_2021 : Supply and fixing cast iron post top lanternd 28W inbuilt LED with shade of size 540x450mm with powder coated finish an giving connection as required. | BI01010001010000000000000515BI0100001218 | 18 | each |